l i nda b we si mpl i f y c onstr u ction Conforms ErP Ecodesign Lot 6 Residential and non-residential air handling units

Similar documents
European Parliament and of the Council with regard to energy labelling of residential ventilation units. (Text with EEA relevance) (2016/C 416/06)

ENERGIA ЕНЕРГИЯ ΕΝΕΡΓΕΙΑ ENERGIJA ENERGY ENERGIE /2014

ENERGIA ЕНЕРГИЯ ΕΝΕΡΓΕΙΑ ENERGIJA ENERGY ENERGIE /2014

ErP. The ErP Directive. New values for fans

Decentralised comfort ventilation unit Zehnder ComfoSpot 50

Ecodesign in SystemairCAD

EVIA Guidance on Ecodesign requirements for ventilation units

HR200WK Through the wall Heat Recovery Ventilator

ERP INFORMATION 1253/2014/EU

Silhouette Installation and Wiring Instructions

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

ErP - COMPLIANT TO EUROPEAN DIRECTIVE VENTILATION UNITS (AHU) TECHNICAL DATA RIGHT VIEW TOP VIEW

The products covered by the Regulation can be classified as follows:

Ecodesign directive 3

We simplify construction

Directive 2009/125 NO ECODESIGN + NO CE-MARK

Lo-Carbon Quadra Centrifugal Fan

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

Energy efficient ventilation equipment

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

B COMMISSION REGULATION (EU)

We simplify construction

Installation manual Mori HR

Lo-Carbon PoziDry Pro

vortice.com RESIDENTIAL VENTILATION VORT HRW 20 MONO RANGE Decentralized heat recovery units NEW

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

AZURE COUNTER FLOW HEAT RECOVERY VENTILATION. aera.com.tr

We simplify construction

G Installation manual Solitude - dmev unit

VORT NRG RANGE COMMERCIAL VENTILATION NEW

COMMISSION REGULATION (EU)

Vireo HR155WM / HR155CM / HR185WM Mechanical Ventilation with Heat Recovery User / Homeowner Guide

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

SYSTEM VENTECH LG 250

RoofVent Design Handbook

Commission Working Document on possible Ecodesign Requirements for domestic ovens, hobs and range hoods

vortice.com RESIDENTIAL VENTILATION VORT HRW 20 MONO RANGE Decentralized heat recovery units NEW

Air handling units Compair. Technical Catalogue

The power of ventilation

A Step by Step Guide to Energy Labelling of Gaseous Fuel Local Space Heaters (Part 1)

COMMISSION REGULATION (EU) No /.. of

ANNEXES. to the. Commission Delegated Regulation

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

COMMISSION REGULATION (EU) No /.. of XXX

SAVE gives great indoor climate and saves energy

The intention is to give to the implementing measures the form of two directly applicable regulations.

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

ANNEXES TO WORKING DOCUMENT ON POSSIBLE ECODESIGN AND ENERGY LABELLING REQUIREMENTS FOR SOLID FUEL BOILERS (< 500 KW)

Flexline NG. Air Handling Unit

- Check Test Methodology for Tumble Dryers Energy Label & Ecodesign -

GSX Gas-fired air heater with axial fan 16 Air heater with premix burner for unrestricted outlet into the room. Output from 16,7 to 83,9 kw.

Air Handling Units. Geniox. Quick guide

l i nda b we si mpl i f y c onstr u ction Lindab Residential Heat Recovery Counterflow - RHR-CF Technical guide

2. SCOPE. OJ L 239, , p. 1. OJ L 239, , p. 83, OJ L 239, , p OJ L 239, , p. 162.

European Technical Assessment ETA 17/1007 of 02/05/2018

(Non-legislative acts) REGULATIONS

(Text with EEA relevance)

Discover ebm-papst for buildings. Energy-efficient fans for a controlled room atmosphere.

Draft COMMUNICATION FROM THE COMMISSION

OJ L 239, , p. 1. OJ L 239, , p. 83, OJ L 239, , p. 136.

HVAC product labelling and certification

COMMISSION REGULATION (EU) No /.. of XXX

Delegated Regulation (EU) 665/2013 of 3 May 2013 supplementing Directive 2010/30/EU with regard to energy labelling of vacuum cleaners

(Non-legislative acts) REGULATIONS

Come On Labels Common appliance policy All for one, One for all Energy Labels. EU-legislation related to energy labels on household appliances

Product Testing. Vacuum cleaner ecodesign and energy labeling requirements EU 665/2013 & EU 666/2013

WORKSHOP VENTILATION- PSYCHROMETRICS-AHU

We thank you for considering the comments from Eurovent and we remain at your disposal for any additional information that you might require.

COMMISSION DELEGATED REGULATION (EU) No /.. of XXX

Delegated Regulation (EU) 1059/2010 of 28 September 2010 supplementing Directive 2010/30/EU with regard to energy labelling of household dishwashers

Air Handling Units. Eurovent Guidebook. Everything you need. of a ventilation system. JULY 2018 First release

COMMISSION REGULATION (EU) No /.. of XXX

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

Working Document on a possible COMMISSION DELEGATED REGULATION

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

Customer id 2452 Project 1152 Unit 189 ACON From Inspection Side. Unit name AHU-22 R.05 Supply air EU m³/sec Exhaust air

Resolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h

Both regulations are due to be reviewed by Key topics to be assessed during the reviews include:

G Installation Manual (installer & user) QR180MBP Heat Recovery Ventilation Unit

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Official Journal of the European Union

EC L2. and humidity sensors. All units are supplied tested and ready to install.

Energy recovery unit. Projection documents

(Non-legislative acts) REGULATIONS

EC A1/L2 RIRS V EKO AIR HANDLING UNITS

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

CEN standardization work on refrigerating systems, especially standard EN 378

G Installation Manual (installer & user) QR350MBP Heat Recovery Ventilation Unit

Cooling & Heating Coils Cooling Towers Drift Eliminators European Heat Pumps Fan Coils Units* Heat Exchangers * Heat Pumps*

ErP. ErP READY. The Eco-Design Directive ErP for refrigerator systems and heat pumps. READY

Guidelines accompanying:

Come On Labels Common appliance policy All for one, One for all Energy Labels. New EU legislation related to energy labels on household appliances

1. Terms defined in the Construction Products Regulation (CPR)

NEW SECTION: ROTARY HEAT EXCHANGER WITH A HEAT PUMP Effective and smart!

Transcription:

l i nda b we si mpl i f y c onstr u ction Conforms ErP 2 0 16 Ecodesign Lot 6 Residential and non-residential air handling units

What is ErP and Ecodesign? ErP stands for Energy Related Products. ErP is supported by Ecodesign Directive (2009/125/EC), which is aiming towards significant reduction of greenhouse gas emissions and overall energy consumption by the year 2020. While supporting efficient use of energy and energy related products and phasing out inefficient products, the Ecodesign Directive also makes energy information and data about energy-efficient products more transparent and easy accessible for consumers. The implementation of the Ecodesign Directive is split into a number of product areas, called lots, focusing especially on the areas with significant energy consumption. Ventilation units are included in Ecodesign Lot 6, concerning ventilation, heating and air conditioning, an area, which represents about 15% of the total energy consumption in the EU. Classification of air handling units Ventilation units are classified either as Residential Ventilation Units (RVU) or Non-Residential Ventilation Units (NRVU). Residential units according to regulation 1254/2014 must be marked with a special energy efficiency label, providing the following information: a) supplier's name or trade mark; b) supplier's model identifier i.e. the code, usually alphanumeric, used to distinguish a specific residential ventilation unit model from other models with the same trade mark or supplier's name; c) specific energy consumption (SEC) in kwh/(m 2.a) for each applicable climate zone and SEC class; d) declared typology in accordance with Article 2 of this Regulation (unidirectional or bidirectional); e) type of drive installed or intended to be installed (multi-speed drive or variable speed drive); f) type of heat recovery system (recuperative, regenerative, none); g) thermal efficiency of heat recovery (in % or not applicable if the product has no heat recovery system); h) maximum flow rate in m 3 /h; i) electric power input of the fan drive, including any motor control equipment, at maximum flow rate (W); j) sound power level (LWA), rounded to the nearest integer; k) reference flow rate in m 3 /s; l) reference pressure difference in Pa; m) SPI in W/(m 3 /h); n) control factor and control typology in accordance with the relevant definitions and classification in Annex VIII Table 1; o) declared maximum internal and external leakage rates (%) for bidirectional ventilation units or carry over (for regenerative heat exchangers only), and external leakage rates (%) for ducted unidirectional ventilation units; p) mixing rate of non-ducted bidirectional ventilation units not intended to be equipped with one duct connection on either supply or extract air side; q) position and description of visual filter warning for RVUs intended for use with filters, including text pointing out the importance of regular filter changes for performance and energy efficiency of the unit; r) for unidirectional ventilation systems, instructions to install regulated supply/exhaust grilles in the façade for natural air supply/extraction; s) internet address for pre-/dis-assembly instructions; t) for non-ducted units only: the airflow sensitivity to pressure variations at + 20 Pa and 20 Pa; u) for non-ducted units only: the indoor/outdoor air tightness in m 3 /h; v) the annual electricity consumption (AEC) (in kwh electricity/a); w) the annual heating saved (AHS) (in kwh primary energy/a) for each type of climate ( average, warm, cold ). 25.11.2014 L 337/39 Official Journal of the European Union EN. The energy labelling is not mandatory for non- residential units. However, it may be still relevant as hallmark for high-quality products, similar to the Eurovent certification, which guarantees the performance of units according to product specifications. 2

Residential ventilation units (RVU) definition: a) the maximum flow rate does not exceed 250 m 3 /h; b) the maximum flow rate is between 250 and 1000 m 3 /h and the manufacturer declares the unit is intended to be used exclusively for a residential ventilation application. Non-residential ventilation unit (NRVU) definition: a) the maximum flow rate of the ventilation unit exceeds 250 m 3 /h, b) where the maximum flow rate is between 250 and 1000 m 3 /h, the manufacturer has not declared the unit to be used exclusively for a residential ventilation application. Non-residential air handling units Energy efficiency acc. to ErP directive for non-residential ventilation units ErP-Stage January 2016 ErP-2016 January 2018 ErP-2018 Heat recovery system (HRS) BVU with thermal by-pass required required HRS BVU minimum Run-around coil system 63 68 thermal efficiency of Plate heat exchangers, heat recovery η [%] rotary heat exchanger 67 73 Filter differential pressure monitoring not required required Minimum fan P sys 30 kw 6.2 In(P sys) +35 6.2 In(P sys) +42 efficiencies UVU ηsys [%] P sys > 30 kw 56.1 63.1 Variable speed drive for fans required required Internal SFP-Value (3) reference configuration [W/(m 3 /s)] Run-around coil system Plate heat exchangers, rotary heat exchanger, miscellaneous BVU (1) q nom < 2 m 3 /s 1,700+E 300 q nom/2 F 1,600+E 300 q nom/2 F q nom 2 m 3 /s 1.400+E F 1.300+E F q nom< 2 m 3 /s 1,200+E 300 q nom/2 F 1,100+E 300 q nom/2 F q nom 2 m 3 /s 900+E F 800+E F UVU (2) 250 230 HRS-Efficiency bonus Run-aroundcoil system (η 0,63) 3,000 (η 0,68) 3,000 E [W/(m 3 /s)] (4) Plate heat exchangers, (η 0,67) 3,000 (η 0,73) 3,000 rotary heat exchanger Filter correction value Reference configuration 0 0 F [W/(m 3 /s)] (5) Filter M5 is missing 160 150 Filter F7 is missing 200 190 Filters M5 + F7 are missing 360 360 (1)... bidirectional ventilation unit (BVU) means a ventilation unit which produces an air flow between indoors and outdoors and is equipped with both exhaust and supply fans (2)... unidirectional ventilation unit (UVU) means a ventilation unit producing an air flow in one direction only, either from indoors to outdoors (exhaust) or from outdoors to indoors (supply), where the mechanically produced air flow is balanced by natural air supply or exhaust (3)... internal specific fan power of ventilation components (SFPint) (W/(m³/s)) is the ratio between the internal pressure drop of ventilation components and the fan efficiency (4) efficiency bonus (E) is a correction factor taking account of the fact that more efficient heat recovery causes more pressure drops requiring more specific fan power; (5) filter correction (F) (Pa) is a correction value to be applied if a unit deviates from the reference configuration of a BVU 3

Lindab air handling units selection made easy The new energy check will be implemented into our selection software AirCalc++ by the end of 2015, as all air handling units, produced for European Market have to fulfill ErP2016 requirements from 1st January 2016. The next step is ErP2018, which will be implemented from 1st January 2018. Our selection program AirCalc++ automatically checks, whether an air handling units fullfils requirements of ErP2016 and ErP2018. Air handling units energy efficiency check After AHU calculation the new indication appears on the top of drawing mask (see below): in accordance with Ecodesign- Directive ErP2016 in accordance with Ecodesign- Directive ErP2018 energy efficiency class according to the table below Reference table for energy efficiency class calculations: 4

Energy efficiency check By clicking on the ErP icon a new window with detailed results appears Calculation is done according to the requirements in the table on page 3 This brochure is a brief summary of Ecodesign Lot 6 (1253/2014). To read the actual Ecodesign Directive itself, please visit http://eur-lex.europa.eu. 5

At Lindab we simplify construction for our customers. We do that by designing easy to use products and solutions, as well as offering efficient availability and logistics. We are also working on ways to reduce our impact on our environment and climate. We do that by developing methods to produce our solutions using a minimum of energy and natural resources, and by reducing negative effects on the environment. We use steel in our products. It s one of few materials that can be recycled an infinite number of times without losing any of its properties. That means less carbon emissions in nature and less energy wasted. We simplify construction Lindab IMP Klima d.o.o. Godovič 150 SI-5275 Godovič Slovenia T: +386 5 374 30 00 F: +386 5 374 30 82 E: imp-klima@lindab.com www.lindab.si