Europe s Leading Manufacturer of Fire + Carbon Monoxide Alarms Need more info? Call us on +353 (0)61 471277 Ei Electronics e-mail: sales@eielectronics.ie web:www.eielectronics.com
Ei Electronics, is an acknowledged market leader in Residential Fire Safety Products, one of Irelands largest indigenous electronic companies. Ei Electronics employs over 500 people at our 18,000 m 2 campus in Shannon and an additional 50 at our r UK Sales/Marketing subsidiary, Aico, located in Oswestry, 20 in Sales/Marketing subsidiary in Germany and 6 in Sales/Marketing in France. Ei Electronics is a 100% Irish owned private Company. It was established in March 1988 following an MBO from GE. (The original GE operation dates back to 1963). The Company has achieved continuous growth through development of a stream of innovative new products manufactured on state of art process s technology, delivered to highest customer service standards. All our products are designed, manufactured and 100% tested at Shannon n plant in Ireland. Quality, Innovation and Service are at heart of Ei Electronic success story. We aim to meet and exceed current product standards and best practices to ensure highest quality and reliability. All our are 3rd party tested and certified to EN standards by recognised world class institutions such as BSI (British Standards Institution) and VdS of Germany. We also manufacture to, and exceed highest quality levels under ISO 9001:2000 standards and ensure 100% testing of all our products and sensors. Fire are potentially life saving devices and it is vital that y provide early detection and warning should a fire break out in a dwelling. Remember When lives are at risk...it pays to fit best. Ei Electronics has always been to forefront of domestic fire alarm technology and has a record of industry firsts including, rechargeable back-up supply, Remote Control functionality, RadioLINK wireless communication, 10 Year battery technology, Multi-Sensor Alarm and many ors. Product development is lifeblood of our business. We believe that very best in alarm technology should be backed by very best Technical Support and Customer Service possible. We offer comprehensive product information, guidance on standards and regulations, local telephone technical support and on site visits. Our Customer Service department are committed to providing best support and assistance. This includes full range product stocking, quick delivery times, regional sales contacts and more. Need more info? Call us on +353 (0)61 471277 Ei Electronics e-mail: sales@eielectronics.ie web:www.eielectronics.com Made in Ireland 1
160RC Series Professional Mains Powered Fire Alarms 10 Year Rechargeable Back-up Battery The rechargeable lithium battery never needs to be replaced and will last in excess of 10 years. The feature Remote Control functionality and are fully compatible with our extensive range of control accessories. The easi-fit design makes for simple and quick installation. Up to 12 can be interconnected to ensure early detection and warning. When one alarm senses fire all will sound. There is also possibility of wireless interconnection when are fitted on an Ei168RC RadioLINK base. Series Features: 200-250VAC mains power 10 year rechargeable lithium battery Built-in Test/Silence button Easi-fit base Remote Test + Control Third party accredited by BSI 5 year guarantee Interconnect up to 12 units Optical Alarm Ei166RC Heat Alarm Ei164RC Ionisation Alarm Ei161RC BS EN 14604:2005 KM552831 BS 5466-2:2003 KM83678 BS EN 14604:2005 KM552831 This optical alarm detects all fire types but is especially sensitive to visible smouldering fires Proven optical sensor chamber Built-in mesh screen to reduce insect and dust contamination Recommended for use in kitchens and garages where smoke may be prone to nuisance from cooking fumes, dust, etc. Heat sensor triggers at 58 C This ionisation alarm detects all fire types but is especially sensitive to fast flaming fires Proven ionisation smoke chamber Unique easi-fit design makes installation simple Bring wiring through and screw easi-fit base to ceiling Wire to built in terminal block and clip on wiring cover Slide alarm on 2
140RC Series Professional Mains Powered Fire Alarms Replaceable Back-up Battery The feature Remote Control functionality and are fully compatible with our extensive range of control accessories. The easi-fit design makes for simple and quick installation. Up to 12 can be interconnected to ensure early detection and warning. When one alarm senses fire all will sound. There is also possibility of wireless interconnection when are fitted on an Ei168RC RadioLINK base. Series Features: 200-250VAC mains power Replaceable alkaline battery back up Built-in Test/Silence button Easi-fit base Remote Test + Control Third party accredited by BSI 5 year guarantee Interconnect up to 12 units Optical Alarm Ei146RC Heat Alarm Ei144RC Ionisation Alarm Ei141RC BS EN 14604:2005 KM552831 BS 5466-2:2003 KM83678 BS EN 14604:2005 KM552831 This optical alarm detects all fire types but is especially sensitive to visible smouldering fires Proven optical sensor chamber Built-in mesh screen to reduce insect and dust contamination Recommended for use in kitchens and garages where smoke may be prone to nuisance from cooking fumes, dust, etc. Heat sensor triggers at 58 C This ionisation alarm detects all fire types but is especially sensitive to fast flaming fires Proven ionisation smoke chamber Unique easi-fit design makes installation simple Bring wiring through and screw easi-fit base to ceiling Wire to built in terminal block and clip on wiring cover Slide alarm on 3
2110 Series Professional Mains Powered Multi-Sensor Fire Alarm 10 Year Rechargeable Back-up Battery Different types of fire are detected in different ways. Some fires produce lots of flames, but little or no smoke, such as chip pans or paper. On or hand, furniture or electrical items produce much thicker smoke but not necessarily lots of flames. The Multi Sensor alarm combines two separate sensor types (Optical and Heat) to give improved performance against all different types of fire. The easi-fit design makes for simple and quick installation. The feature Remote Control functionality and are fully compatible with our extensive range of control accessories. Up to 12 can be interconnected to ensure early detection and warning. When one alarm senses fire all will sound. There is also possibility of wireless interconnection when are fitted on an Ei168RC RadioLINK base. Unique Automatic Dust Compensation Virtually Eliminates Nuisance Alarms Best for Slow Smouldering and Fast Flaming Fires Line shows amount of smoke needed in sensor chamber to trigger an alarm The alarm automatically recalibrates alarm trigger point to compensate for dust DUST The optical sensor chamber continually self-monitors minute changes in dust levels, automatically readjusting point that will trigger an alarm. The two sensors work toger intelligently to monitor signs of fire giving best response in case of a real fire, and avoiding a false alarm if no signs of fire are detected. Alarm Features: 200-250VAC mains power 10 year rechargeable lithium battery Built-in Test/Silence button Easi fit base Remote Test + Control Third party accredited by BSI 5 year guarantee Interconnect up to 12 units BS EN 14604:2005 KM552831 Unique easi-fit design makes installation simple Bring wiring through and screw easi-fit base to ceiling Wire to built in terminal block and clip on wiring cover Slide alarm on 4
Ei168RC RadioLINK Base Mains Powered RadioLINK Transceiver 10 Year Rechargeable Back-up Battery Linking smoke with RadioLINK simplifies interconnection in properties. There s no tricky wiring runs, no unsightly trunking, and no need for redecorating after you ve finished. Instead, RadioLINK uses Radio Frequency (RF) signals to interconnect. Simply connect base to nearest lighting circuit, slide alarm on, n House Code units to link m toger as a and prevent m from picking up signals from any units in neighbouring properties. Base Features: No interconnect cabling between RF signals are used instead Eliminates tricky wiring runs between Mains powered with rechargeable Lithium battery Fit a RadioLINK base under each alarm to be connected Slide your choice of Multi-Sensor, Smoke or Heat alarm onto RadioLINK base Any alarm from 2110, 160RC or 140RC Series can be used Easi-fit design makes installation simple 5 year guarantee About RadioLINK Base The RadioLINK base is key part to any mains powered RadioLINK alarm. A base needs to be fitted under each alarm in. Built-in terminal block with clip-on wiring cover Alarm slides on and tamper-proof locking latch prevents unwanted removal House Code light flashes to show how many units are coded toger making set-up easy House Code slot. Simply insert screwdriver to set-up Rechargeable back-up is automatically switched on as alarm slides on 5
RadioLINK Operation How does RadioLINK work? RadioLINK uses a mesh, which means that pass RF signal between m, repeating signal on so that all of sound. This means that re are multiple paths for RF signal to travel along, so even if re is an obstruction, signal will be repeated around it. Alternative routes for signal How far can signals travel? The signal can travel 100 metres in free air. RadioLINK signals will pass through walls and ceilings, but thick stone walls or metal structures can reduce ir strength. That s why it s important to use a mesh that gives signal multiple paths to reach each alarm. Barrier to RF signal Can anything cause interference? The RadioLINK signals are on 868MHz RF band which is tightly controlled by standards and regulations. You don t have to worry about Wi-Fi, Bluetooth or car key fobs none of se work on same frequency. RadioLINK has been used for more than 10 years without any interference from or devices. After have been installed, y should be House Coded toger to prevent from picking up signals in neighbouring properties. House Coding gives its own unique code, so it will only respond to or units in that. RadioLINK Product Range: RadioLINK base under easi-fit : RadioLINK Alarms: 2100 Series 160RC Series 140RC Series 600 Series RadioLINK battery fire RadioLINK mains and battery CO Alarms Accessories: Ei450 Alarm Controller Ei407 Manual Call Point Ei408 Switched Input Module Ei428 Relay Module Ei413 Panel Interface Module Ei170RF Alarm for Hard of Hearing 6
Professional 10 Year Alarms Powered for life Lithium battery Ei650C Smoke Alarm Series Ei650W Smoke Alarm Series Ei603TYC Heat Alarm Series BS 5446-2 2003 Optical Smoke Alarm 10 year lithium battery Large Test + Hush Hardwire interconnect up to 12 units Wireless interconnect option Wireless Remote control option Optical Smoke Alarm 10 year lithium battery Large Test + Hush Wireless interconnect option Wireless Remote control option Heat Alarm 10 year lithium battery Large Test + Hush Hardwire interconnect up to 12 units Wireless interconnect option Wireless Remote control option Ei650M RadioLINK Module Ei650M RadioLINK Module Ei605MTYRF RadioLINK Module Plug-in module 10 year battery Add to Ei650C Plug-in module 10 year battery Add to Ei650W Plug-in module 10 year battery Add to Ei603TYC Model Power Wired Interconnect RadioLINK Ei650C 10 Year Lithium Yes add Ei650M Ei650W 10 Year Lithium No add Ei650M Ei603TYC 10 Year Lithium Yes add Ei605MTYRF Ei650* 10 Year Lithium No No * Ei650 is a stand alone option with no interconnection possible 7
Professional Alarms Replaceable battery Ei605 Smoke Alarm Series Ei605C Smoke Alarm Series Ei603C Heat Alarm Series BS 5446-2 2003 Optical Smoke Alarm Replaceable alkaline battery Large Test + Hush Optical Smoke Alarm Replaceable alkaline battery Large Test + Hush Hardwire interconnect up to 12 units Wireless interconnect option Wireless Remote control option Heat Alarm Replaceable alkaline battery Large Test + Hush Hardwire interconnect up to 12 units Wireless interconnect option Wireless Remote control option Ei605MRF RadioLINK Module Ei605MRF RadioLINK Module Plug-in module 10 year battery Add to Ei605C Plug-in module 10 year battery Add to Ei603C Model Power Wired Interconnect RadioLINK Ei605* 9V Alkaline No No Ei605C 9V Alkaline Yes add Ei605MRF Ei603C 9V Alkaline Yes add Ei605MRF * Ei605 is a stand alone option with no interconnection possible 8
Carbon Monoxide Alarms Professional Series Carbon Monoxide (CO) is a killer. It s a toxic gas that has no taste, smell or colour it s impossible for human senses to tell that it s re. Sources of Carbon Monoxide (CO) CO BOILER CO CO GAS COOKER Exposure to low levels of CO can result in flu like symptoms, causing headaches, drowsiness and nausea. High levels can kill within minutes. CO is produced by incomplete combustion, so it can come from any fuel burning appliance. Blocked, cracked or corroded flue/vent Back drafting through chimney/flue Appliance without flues Ei208W - Battery Alarm Ei208DW - Battery Alarm with Display Ei200MRF RadioLINK Module BS EN50291-2: 2010 BS EN50291-1: 2010 BS EN50291-2: 2010 BS EN50291-1: 2010 10 year lithium battery Powered for life Memory feature indicates last recorded CO level Large, easy-to-use test button Wireless interconnect option Wireless Remote Control option 10 year lithium battery - Powered for life Digital display shows level of CO detected and or warning messages Memory feature indicates last recorded CO level Large, easy-to-use test button Wireless interconnect option Wireless Remote Control option RadioLINK communication for Ei208W and Ei208DW Ei261ENRC Mains Powered Alarm Ei261DENRC Mains Powered Alarm + Display Ei262 Mains Powered Alarm + RadioLINK BS EN 50291 :2010 BS EN 50291 :2010 BS EN 50291 :2010 9 Mains Powered Alarm with 10 year rechargeable lithium back-up Replaceable sensor gives 10yr+ alarm life Hardwire interconnect only Digital display shows level of CO detected Mains Powered Alarm with 10 year rechargeable lithium back-up Replaceable sensor gives 10yr+ alarm life Hardwire interconnect only Mains Powered Alarm with 10 year rechargeable lithium back-up Replaceable sensor gives 10yr+ alarm life Built-in RadioLINK interconnect + Remote Control functionality
RadioLINK Alarm Systems Powered for life Lithium Battery BS 5446-2 2003 Key Features Integrated RadioLINK Module Wireless interconnect Wireless Remote Control Supports RadioLINK add-on accessories 5 Year Guarantee Integrated RadioLINK Module Model Type Power Standards Ei650CRF Optical 10 Year Lithium Battery EN14604 Ei603TYCRF Heat 10 Year Lithium Battery BS5446-2 RadioLINK Alarm Systems 9V Replaceable battery BS 5446-2 2003 Key Features Integrated RadioLINK Module Wireless interconnect Wireless Remote Control Supports RadioLINK add-on accessories 5 Year Guarantee Integrated RadioLINK Module Model Type Power Standards Ei605CRF Optical 9V Replaceable EN14604 Ei603CRF Heat 9V Replaceable BS5446-2 10
Ei413 Panel Interface Module Conventional Fire + Security Panels Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 Product Description The Ei413 Panel Module provides an interface between an Ei Electronics RadioLINK and a security or fire panel. A RadioLINK may consist of Ei Electronics Smoke, Heat, CO Alarms along with accessory devices that are linked using proprietary RadioLINK protocol. The Ei413 must be coded to or RadioLINK devices in. The Ei413 requires an 11-30VDC supply which is normally taken from panel. The Ei413 decodes Fire, CO and Fault signals from RadioLINK devices and activates relevant onboard relays. The relays are wired to input terminals on panel. The NO (normally open) voltage free contacts input and/or DC voltage input, when activated, will result in Ei413 transmitting a wireless Fire Alarm signal that will sound all in RadioLINK. These inputs are activated by a Fire Alarm signal or a Test Alarm signal from panel. The Ei413 uses RadioLINK multi-repeater, multi-path technology to deliver very robust and reliable RF signal coverage. Smoke or Heat Detector Manual Call Point Smoke or Heat Detector Manual Call Point END OF LINE DEVICE TYPICAL DETECTOR CIRCUIT WIRING ZONE 1 EOL Device Ei413 Wireless Interface Module Ei600 Series Smoke or Heat Alarm Ei407 Manual Call Point Ei600 Series Smoke or Heat Alarm Ei411H Remote Control Switch TYPICAL Ei ALARM CIRCUIT WIRING ZONE 3 EOL Device Ei413 Wireless Interface Module Ei600 Series Smoke or Heat Alarm Ei407 Manual Call Point Ei600 Series Smoke or Heat Alarm Ei411H Remote Control Switch TYPICAL Ei ALARM CIRCUIT WIRING ZONE 6 Wireless Interface Solutions END OF LINE DEVICE TYPICAL DETECTOR CIRCUIT WIRING ZONE 8 Smoke or Heat Detector Manual Call Point Smoke or Heat Detector Manual Call Point For convenience Ei413 may be mounted inside panel but care needs to be taken that RF signal path is robust and reliable. We do not recommend that Ei413 be placed inside a metal enclosure or in a position where RF signal could be seriously attenuated. We recommend that close attention is paid to positioning of Ei413 during installation. 11
RadioLINK System Add-Ons Ei407 Manual Call Point For use with RadioLINK Fire Manual activation of RadioLINK Alarms 10 year sealed-in battery completely wire free An occupant sees a fire before occupant have An seesactivated a fire before The occupant presses blackoccupant dot on Ei407 The presses The Ei407 sends a RadioLINK signal All in property sound The Ei407 sends a RadioLINK signal An occupant sees a fire before An occupant seesactivated a fire before have have An occupant seesactivated a fire before An occupant seesactivated a fire before have have activated The occupant presses The occupant presses black dot on Ei407 black dot on Ei407 The occupant presses The occupant presses black dot on Ei407 black dot on Ei407 The Ei407 sends a RadioLINK signal The Ei407 sends a RadioLINK signal All in property sound All in property sound The Ei407 sends a RadioLINK signal The Ei407 sends a RadioLINK signal All in property sound All in property sound A fire starts which activates aa sprinkler fire starts which activates The Sprinkler Flow Switch which triggersflow Ei408 The Sprinkler Switch The Ei408 sends a RadioLINK signal to sound The Ei408 sendsalla RadioLINK A fire starts which activates fire starts which activates aa sprinkler aa sprinkler fire starts which activates fire starts which activates aa sprinkler a sprinkler The Sprinkler Flow Switch The Sprinkler Switch which triggersflow Ei408 which triggersflow Ei408 The Sprinkler Switch The Sprinkler Switch which triggersflow Ei408 which triggers Ei408 The Ei408 sends a RadioLINK The Ei408 sendsalla RadioLINK signal to sound signal to sound The Ei408 sendsalla RadioLINK The Ei408 sendsalla RadioLINK signal to sound signal to sound all ing Test will test all in will ing Test (y will all test all in sound) Locate to alllocate, excepttofor one all that, has been activated except for A fire starts & Smoke/Heat Alarm is triggered A fire starts & Smoke/Heat A RadioLINK alarm signal is RadioLINK sent to Ei428 A alarm signal The Ei428 is activated and Strobe flashes The Ei428 is activated and A fire starts & Smoke/Heat A fire starts & Smoke/Heat Alarm is triggered Alarm is triggered A fire starts & Smoke/Heat A fire starts & Smoke/Heat Alarm is triggered Alarm is triggered A RadioLINK alarm signal A RadioLINK alarm signal is sent to Ei428 is sent to Ei428 A RadioLINK alarm signal A RadioLINK alarm signal is sent to Ei428 is sent to Ei428 The Ei428 is activated and TheStrobe Ei428 is activated and flashes flashes TheStrobe Ei428 is activated and TheStrobe Ei428 is activated and flashes Strobe flashes A fire starts & Smoke/Heat Alarm is triggered A fire starts & Smoke/Heat A RadioLINK alarm signal is sent to Ei170RF A RadioLINK alarm signal The Ei170RF is activated causing to flash & pad causing to vibrate Thestrobe Ei170RF is activated A RadioLINK alarm signal A RadioLINK alarm signal is sent to Ei170RF is sent to Ei170RF A RadioLINK alarm signal A RadioLINK alarm signal is sent to Ei170RF is sent to Ei170RF The Ei170RF is activated causing Thestrobe Ei170RF is activated to flash & pad causing to vibrate to flash & pad causing to vibrate Thestrobe Ei170RF is activated Thestrobe Ei170RF is activated to flash & pad causing to vibrate strobe to flash & pad to vibrate have activated black dot on Ei407 All in property sound Ei408 Switched Input Module For use with RadioLINK Fire Activates RadioLINK Alarms on detection of an external event, e.g. sprinkler 10 year sealed-in battery completely wire free a sprinkler which triggers Ei408 signal to sound all Ei411 / 412 Alarm Control Switches Test, Locate and Silence from one point 10 year sealed-in battery completely wire free Ei411 is a fire alarm control switch Ei412 is a Fire + CO Alarm control switch (y will all sound) ing Test will ing Test test all in will test all in sound) will ing Test (y will all (y will all ing Test test all in sound) will test all in sound) (y will all (y will all sound) one that has been activated Locate to alllocate, excepttofor all, except Locate tofor one that has been activated one that has been activated Locate tofor all, except except for one all that, has been activated one that has been activated Silence to in Silence to in Silence Silence to in to in Silence Silence to in to in Ei428 Relay Module For use with RadioLINK Fire RadioLINK alarm signal will activate SAB300 strobe light, Y03 siren and or devices 200-250VAC 10 year rechargeable backup Ei170RF Hard of Hearing Alarm Panel Alarm is triggered is sent to Ei428 Strobe flashes For use with RadioLINK Fire RadioLINK alarm signal activates strobe and vibration pad 200-250VAC 10 year rechargeable backup Ei450 Alarm Controller Alarm is triggered A fire starts & Smoke/Heat A fire starts & Smoke/Heat Alarm is triggered Alarm is triggered A fire starts & Smoke/Heat A fire starts & Smoke/Heat Alarm is triggered Alarm is triggered is sent to Ei170RF strobe to flash & pad to vibrate For use with RadioLINK Fire and CO 10 year sealed-in battery completely wire free One button, three functions: - Test, locate & Silence ing will test all ing in will (y will all test all in sound) (y will all sound) ing will ing in will test all test all in will ing (y will all sound) (y will all sound) ing in will test all test all in sound) (y will all (y will all sound) to all, excepttofor one that, has been activated all except for one that has been activated to all, excepttofor one all, except one been tofor that has activated that has been activated all, excepttofor one all, except for one that has been activated that has been activated to in to in to in to in to in to in 12
Ei100 Series Battery Powered Fire Alarms BS EN 14604:2005 KM552831 Key Features 9V Replaceable battery Battery removed indicator Built-in sounder Test Low battery indication 5 Year Guarantee Model Type Power Additional Feature Standards Ei100B Ionisation 9V Replaceable Extra sensitive to fast flaming fires EN14604 Ei100L Ionisation 9V Replaceable with emergency escape light EN14604 Ei100S Ionisation 9V Replaceable with hush button for nuisance EN14604 Ei103C Heat 9V Replaceable Triggers at 58º BS5446-2 Ei105B Optical 9V Replaceable Extra sensitive to slow smouldering fires EN14604 Ei3100 Series Battery Powered Wireless Fire Alarms Key Features BS EN 14604:2005 KM552831 Built-in Wireless functionality 9V Replaceable battery Battery removed indicator Built-in sounder Test Low battery indication 5 Year Guarantee Model Type Power Additional Feature Standards Ei3100RF Ionisation 9V Replaceable Extra sensitive to fast flaming fires EN14604 Ei3103RF Heat 9V Replaceable Triggers at 58ºC BS5446-2 Ei3105RF Optical 9V Replaceable Extra sensitive to slow smouldering fires EN14604 13
Carbon Monoxide Alarms Replaceable Battery Series CO Alarm features: Loud, distinctive alarm 85dBA at 3 metres Memory feature indicates last recorded CO level Third Party Accredited by BSI 5 year guarantee Made in Ireland Ei207 Battery Alarm Ei207D Battery Alarm Ei205EN Battery Alarm BS EN50291-2: 2010 BS EN50291-1: 2010 BS EN50291-2: 2010 BS EN50291-1: 2010 BS EN 50291 :2010 9V Replaceable battery Large, easy-to-use test button 9V Replaceable battery Large, easy-to-use test button Digital display shows level of CO detected and or warning messages 9V Replaceable battery Memory function 14
Need more info? Call us on +353 (0)61 471277 Ei Electronics e-mail: sales@eielectronics.ie web:www.eielectronics.com Made in Ireland