AutroFlame X33AF. Addendum. Multi-spectrum IR flame detector. Protecting life, environment and property...

Similar documents
Addendum HART Communication with the X2200 UV Flame Detector 1.1 4/

Document TM777030, rev. B. Initial release: 22 January 2008 Current release: 16 February 2010

Addendum. HART Communication with the FlexSonic Acoustic Detector. 1.1 Rev: 1/

Instructions AutroFlame IR Flame Detector BG-201/BG-21

FlameGard 5 UV/IR HART

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

Operator's Handbook. Interactive Fire Alarm System Release 3. Information Panel, BV-320. Protecting life, environment and property...

FlameGard 5 MSIR HART

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

Installation Handbook. Interactive Fire Alarm System Release 3. Operator Panel, BS-330. Protecting life, environment and property...

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

Instructions AutroVu Explosion-Proof Universal Display AV20

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

System Description AutroMaster V Presentation System

Instructions FlexVu Explosion-Proof Universal Display Unit Model UD Rev: 9/

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X

General Routing Interface

Rosemount 3051S MultiVariable Transmitter

SAFETY MANUAL. Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS)

OVEN INDUSTRIES, INC.

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

ECO N DATE DESCRIPTION OF CHANGE CHG

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Laptop / PC Programming Manual

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

CU-02 with Senaco Plus

*IG1583EW* Aurora Touch UPC Kit Instruction Guide. Aurora Touch UPC Kit Instruction Guide

Instructions Electrochemical Toxic Gas Detector GT3000 Series Includes Transmitter (GTX) and Sensor Module (GTS) 5.

Instructions. FlexVu Explosion-Proof Universal Display Unit Model UD Rev: 6/

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

ADDENDUM. xwatch Explosion-Proof Camera with X-Series Flame Detectors DESCRIPTION GENERAL APPLICATION INFORMATION

TEC Controller Terminal Box Controller (VAV) - with Hot Water Reheat, Application Application Note Building Technologies

Waters 2695 Separations Module

REPEATER FS5200R INSTRUCTION MANUAL

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

TEC Controller Terminal Box Controller (VAV) - Series Fan Powered with Hot Water Reheat, Application Application Note

Installation, Operating and Maintenance Manual

Manual Supplement. Model Number: 8680-N2. Communications Protocol. Contents of this manual supplement include:

Process & TeMPerATUre UniversAl input DigiTAl MeTers

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

Instruction Manual December 2001 ENACOCU02

Waters 2795 Separations Module

Ax60+ Multi-Gas. Service Manual

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

GLD-30 Gas Leak Detector

BSR Addressable Fire Detection control panel. Installation operation manual

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

Waters 2695D Separations Module

PRODUCT BULLETIN. Rev. A Monitoring Station offering PN Rev. B as a direct replacement. OVERVIEW / DESCRIPTION

Autronica Fire and Security AS ID:

EXTINGUISHING AGENT RELEASE MODULE

Across-the-Line SERIES MP300 Combined Manual and Automatic

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

Intelligent Security & Fire Ltd

STT850 and STT750 SmartLine Temperature Transmitter HART Communications Options Safety Manual 34-TT Revision 4 September 2017

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

The EN54 Part 2 & 4 Fire System

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Module Features are-configurable, no module jumpers to set

Soft Start Series MP700 Solid State, Reduced Voltage

FiRe mobile-2 Operation Manual

System 800 Addressable Fire Detection & Alarm System

Operator's Handbook. Release 3. Fire Alarm Control Panel, BS-310 / 320 / Operator Panel BS-330. System Program Version 3.8.0

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

UNC100 Integra Manual

Instruction Manual August sitrans CU 02

200i/KN2, KN4 Firmware Revision Sheet

FUNCTIONAL SAFETY MANUAL

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

HERCULES 6 GRAPHICS SYSTEM

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

TEC Controller VAV 0-10V Fan Control with Hot Water Heat, Application Application Note Building Technologies

TEC Controller Unit Conditioner - Two-Pipe Fan Coil Cooling or Heating, Application Application Note Building Technologies

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

RPM1600 Series Room Pressure Monitors

rvm4c Installation Guide Remote Video Module

4100U City and Relay Cards Installation Instructions

Intelligent Security & Fire Ltd

F Technical Bulletin SC 370 SMART Modbus Interface

LineGuard 2300 Program User Manual (FloBoss 107)

MODEL B2 INSTALLATION MANUAL

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

User Guide OI/FEX100HART EN Rev. A. WaterMaster FEX100 HART Field Device Specification

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

STEAMPAK Series BurnerPAK BMS Burner Management Systems

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Memcom Emergency Telephone

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Transcription:

AutroFlame X33AF Multi-spectrum IR flame detector Addendum Protecting life, environment and property... 116-P-X33AFADDENDUM/YGB, DEC P/N 95-8624, 2007-11-12

COPYRIGHT This publication, or parts thereof, may not be reproduced in any form, by any method, for any purpose. Autronica Fire and Security AS and its subsidiaries assume no responsibility for any errors that may appear in the publication, or for damages arising from the information in it. No information in this publication should be regarded as a warranty made by Autronica Fire and Security. The information in this publication may be updated without notice. Product names mentioned in this publication may be a trademark. They are used only for identification.

Table of Contents Table of Contents 1. Introduction...3 1.1 About this manual... 3 1.2 The reader...3 1.3 Other reference documents... 3 2. Interconnecting the communicator with the detector...4 3. HART Device Description Language...7 4. Detector Wiring...8 5. HART Menu Structure...9 6. X33AF Root Menu...10 7. Device Info Menu...11 8. General Info Menu...12 9. HART Info Menu...13 10. HART PV Menu...14 11. Condensed Status...15 12. Status Info Menu...16 13. Hardware Menu...17 14. Oi Menu...18 15. Detector Settings...19 16. HISTORY MENU...20 17. Command Menu...21 Page 1

Table of Contents 18. HART CMD Menu...22 19. Device Setup Menu...22 20. Configuration Menu...23 21. Calibration Menu...23 22. Write Protect...24 23. HART Setup...25 24. Set Real Time Clock...25 25. Reader s comments...27 Page 2

Introduction 1. Introduction 1.1 About this manual This manual provides supplementay information for the AutroFlame X33AF multispectrum IR flame detector. Digital communication with the X33AF allows the operator to monitor the status of the detector, determine factory settings, adjust field settings, and initiate field tests. This addendum provides guidance for establishing HART communication, and describes the HART menu structure when using the X33AF with a HART Handheld Communicator, a PC, or other process interface device that supports DDL. 1.2 The reader This handbook is intended for Autronica personnel authorized to install the AutroFlame X33AF multispectrum IR flame detector. NOTE A minimum level of understanding with regard to the operation and navigation of the HART Communicator is required. 1.3 Other reference documents For further information about the AutroFlame X33AF multispectrum IR flame detector, refer to the following: Manual Datasheet Handbook Article no. 116-P-X33AF/CE 116-P-X33AF/DE Page 3

Interconnecting the communicator with the detector 2. Interconnecting the communicator with the detector Point-to-Point Mode The HART Communicator can connect to the X33AF at any wiring termination point in the analog output signal loop. Connect the HART communicator in parallel with the X33AF analog signal or load resistor. The HART connections are non-polarized IMPORTANT WIRING NOTE The HART Communicator does not measure loop current directly, but instead reads a voltage signal across a resistance (250 ohms) in the loop. The recommended connection point is across the input impedance of the signal receiver (PLC), which is a nominal 250 ohms. See Figures 1 to 4. If testing/programming on a bench, a 250 ohm load resistor must be used. See Figure 5. Switch on the HART Communicator. If a device is found, the HART Communicator displays the Main menu. If no device is found, check the connections and verify the presence of a minimum of 250 ohms load resistance in series in the loop. Page 4

Interconnecting the communicator with the detector Figure 1 X33AF Detector Wired for Non-Isolated 4 to 20 ma Current Output (Sourcing) Figure 3 X33AF Detector Wired for Non-Isolated 4 to 20 ma Current Output (Sinking) Figure 2 X33AF Detector Wired for Isolated 4 to 20 ma Current Output (Sourcing) Figure 4 X33AF Detector Wired for Isolated 4 to 20 ma Current Output (Sinking) *Nominal input impedance of PLC = 250 ohms. Maximum loop impedance including input impedance of PLC = 875 ohms. Figure 5 Wiring the X33AF for Benchtop Testing/Programming Using HART Protocol Page 5

Interconnecting the communicator with the detector Multidrop Mode Optical flame detectors are life safety devices and require the 4-20 ma loop for transmitting important detector status data. They should not be used in conjunction with multidrop mode. If multidrop mode is a requirement, the alarm and fault relay contacts must be connected directly to the safety system or fire panel for signalling purposes. NOTE This addendum covers HART wiring only. Refer to the device instruction manual for NFPA-72 compliant releasing wiring diagrams. Page 6

HART Device Description Language 3. HART Device Description Language The HART protocol incorporates a concept called the Device Description Language (DDL) that enables all suppliers of HART instruments to define and document their products in a single consistent format. This format is readable by handheld communicators, PCs and other process interface devices that support DDL. DDL enables full interoperability of devices, regardless of manufacturer, allowing full functionality from any HART device. In the event that your Communicator does not establish communications with the X33AF, ensure that the appropriate DDLs for the X33AF have been programmed into your Communicator. To review the DDLs programmed into your HART Communicator: 1. From the Main menu, access the Offline menu. 2. From the Offline menu, select New Configuration to access the list of device descriptions programmed into the HART Communicator. 3. Select Det-Tronics and review the list of models to determine if the X33AF DDLs are installed in your Communicator. If the X33AF DDLs have not been programmed into the Memory Module, you must use the generic interface built into your HART Communicator. The HART Communication Foundation manages a library of Manufacturer Device Descriptions, which are distributed to programming sites for inclusion in master devices. A complete listing of the HCF DD Library is available for download in manufacturer and device type sequence at www.ccsi.com/hart. Page 7

Detector Wiring 4. Detector Wiring Refer to the X33AF instruction manual for complete instructions regarding detector installation and wiring. However, note that the device power consumption specifications for the HART model are different than the standard model. Power Consumption Specifications of X33AF Detector with HART Communication Without heater: 4.7 watts at 24 vdc nominal; 6.1 watts at 24 vdc in alarm. 5.5 watts at 32 vdc nominal; 7.4 watts at 32 vdc in alarm. Heater only: 8 watts maximum. Total power: 17 watts at 32 vdc with EOL resistor installed and heater on maximum. EOL resistor must be ceramic, wirewound type, rated 5 watts minimum, with actual power dissipation not to exceed 1.5 watts. Page 8

HART Menu Structure 5. HART Menu Structure Page 9

X33AF Root Menu 6. X33AF Root Menu When HART communication is established, the first menu displayed is the X33AF Root menu: When HART communication is established, the first menu displayed is the X33AF Root menu: 1) Fire (Yes/No) Indicates Y if the device is in a fire alarm status analog output is at 20 ma, fire alarm relay is actuated and LED is red. 2) Fault (Yes/No) Indicates Y if a fault condition exists. Go to Device Info and select Status Info to determine the nature of the fault. 3) Device Info Menu Provides access to manufacturer and HART information, current device status, factory settings, and history logs. 4) Command Menu This menu allows the operator to initiate a manual Oi test and also to perform various reset/clear functions. 5) Device Setup Menu This menu allows various setup, configuration and calibration functions. Page 10

Device Info Menu 7. Device Info Menu This menu allows access to a variety of read only information. 1) General Info Menu Factory information. 2) HART Info Menu HART Specific Variables. 3) Status Info Menu Current operating status and/or diagnostic information. 4) Detector Settings Factory settings relating to relay operation, detector sensitivity and response. 5) History Menu Display log files: Alarm, Fault, General. Page 11

General Info Menu 8. General Info Menu 1) Manufacturer Det-Tronics. 2) Model X3301. 3) Serial Number Serial number of device. 4) Part Number Manufacturer s part number for this device. 5) Manufactured Date Date of manufacture shown as XX/XX/XX (month/day/year). 6) Snsr Fmwr Ver Firmware revision level of sensor module. 7) HART Fmwr Ver Firmware revision level of HART Interface Board (HIB). 8) Real Time Clock Current time and date settings of real time clock. 9) Write Protect (Y/N) This indicates whether variables can be written to the device, or whether commands that cause actions to be performed in the device can or cannot occur. Page 12

HART Info Menu 9. HART Info Menu 1) Universal Rev HART universal revision. 2) Field Device Rev HART field device revision. 3) Final Asmbly No. A number that is used for identification purposes, and is associated with the overall field device. 4) Tag Text that is associated with the field device installation. This text can be used by the operator in any way. 5) Date Any date chosen by the operator to be used for any purpose. 6) Descriptor Text associated with the field device that can be used by the operator in any way. 7) Message Text associated with the field device that can be used by the operator in any way. 8) Num Req Preams HART specific synchronization messages. 9) HART PV Menu Display HART specific primary variable (PV) items. 10) Condensed Status Device status condensed for HART handheld display. Page 13

HART PV Menu 10. HART PV Menu 1) PV Unit Not implemented for X33AF. 2) PV Not implemented for X33AF. 3) PV SNSR Unit Not implemented for X33AF. 4) PV USL Not implemented for X33AF. 5) PV LSL Not implemented for X33AF. 6) PV MIN SPAN Not implemented for X33AF. 7) PV DAMP Not implemented for X33AF. 8) PV AO Analog Output. The value that tracks the Digital Value representation, under normal operating modes. 9) PV AO ALRM TYP Not implemented for X33AF. 10) PV % RNGE Percent of Range. The variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. 11) PV XFER FNCTN Not implemented for X33AF. 12) PV RNGE Unit Not implemented for X33AF. 13) PV URV Not implemented for X33AF. 14) PV LRV Not implemented for X33AF. 15) PV SNSR S/N Not implemented for X33AF. Page 14

Condensed Status 11. Condensed Status 1) Xmtr Addstatus 0 Fire Alarm Oi Cal Active Manual Oi Active Warmup 2) Xmtr Addstatus 1 Spare 3) Xmtr Addstatus 2 Fault Auto Oi Fault Manual Oi Fault Oi Cal Fault Dim Detect Fault (Diminished detection fault) Detect Disable Flt (Detection disabled fault) Temp Out of Range Volt Out of Range (Operating voltage out of range) 4) Xmtr Addstatus 3 Snsr HW Fault (Sensor hardware fault) HART HW Fault (HART hardware fault) Intern Comm Fault (Modbus communication fault) Incompatible Fault 5) Operating Mode Fault Fire Alarm 6) Operating Mode 2 Spare Page 15

Status Info Menu 12. Status Info Menu This menu (read only) shows extensive status information about the detector. 1) Warmup (Y/N) Device is in the power-up time delay (warm-up) mode. 2) Fire (Y/N) Indicates Y if the device is in a fire alarm status analog output is at 20 ma, fire alarm relay is actuated and LED is red. 3) Auto Oi Fault (Y/N) Automatic Oi Fault. Check viewing windows and Oi reflector plate for cleanliness. 4) Dim Detect Fault (Y/N) Diminished Detection Fault. Excessive background IR radiation. Eliminate IR interference and/or reaim/orient detector. 5) Detect Disable Flt (Y/N) Flame detector function has been disabled. Check viewing windows for cleanliness and/or presence of excessive background IR signal. 6) Snsr Hdwr Fault (Y/N) Sensor hardware fault. 7) HIB Hdwr Fault (Y/N) HART Interface Board hardware fault. 8) Int Comm Fault Internal communication fault. 9) Incompatible Flt Sensor module firmware version is not compatible with HART Interface Board. 10) Voltage Fault (Y/N) Detector operating voltage is out of tolerance. 11) Hardware Menu Refer to sub-menu. 12) Oi Menu Refer to sub-menu. Page 16

Hardware Menu 13. Hardware Menu 1) Heater Power Actual heater power (0 to 100%). Heater prevents condensation and icing on the detector optics. 2) Heater Setpoint Maximum amount of heater power allowed (in percent of full power). 3) Temperature Actual integral temperature of detector. 4) Temp Setpoint Temperature at which heater begins operating. 5) Temp Range Fault Detector integral temperature out of range Operating range: 40 F to +167 F ( 40 C to +75 C). 6) Voltage Actual detector supply voltage (must be 18 to 32 Vdc). 7) Volt Range Fault Supply voltage is out of range. Operating voltage must be 18 to 32 Vdc. Page 17

Oi Menu 14. Oi Menu 1) Left Oi Percentage of calibrated Oi test signal returned by the left sensor. Reading should be 90 to 100 percent. If reading is below 90 percent, go to Device Setup, select Calibration, and perform Oi Calibration. 2) Middle Oi Percentage of calibrated Oi test signal returned by the middle sensor. Reading should be 90 to 100 percent. If reading is below 90 percent, go to Device Setup, select Calibration, and perform Oi Calibration. 3) Right Oi Percentage of calibrated Oi test signal returned by the right sensor. Reading should be 90 to 100 percent. If reading is below 90 percent, go to Device Setup, select Calibration, and perform Oi Calibration. 4) Oi Fail Count Number of consecutive Oi failures counted (one passed Oi test resets the counter). 5) No. Oi Failures Set (allowable) number of consecutive Oi failures to produce a fault. 6) Oi Cal Active Oi calibration is in progress. 7) Oi Cal Fault An Oi calibration fault has occurred. 8) Manual Oi Active A manual Oi test is in progress. 9) Manual Oi Fail The detector has failed the last manual Oi test. Page 18

Detector Settings 15. Detector Settings This menu shows factory settings relating to relay operation, detector sensitivity and response. 1) Fire Relay (L/NL) Fire relay contacts, latching (L) or non-latching (NL). 2) Fire Relay (NDE/NE) Fire relay coil, normally de-energized (NDE) or normally energized (NE). 3) Fault Relay (L/NL) Fault relay contacts, latching (L) or non-latching (NL). 4) Fault Relay (NDE/NE) Fault relay coil, normally de-energized (NDE) or normally energized (NE). 5) Aux Relay (L/NL) Auxiliary relay contacts, latching (L) or nonlatching (NL). 6) Aux Relay (NDE/NE) Auxiliary relay coil, normally de-energized (NDE) or normally energized (NE). 7) Sensitivity (VH/H/M/L) Detector sensitivity setting: Very high, High, Medium, or Low. 8) Response (.5/3/6/9) Fire alarm processing time in seconds. Page 19

HISTORY MENU 16. HISTORY MENU This menu provides historical information about the detector. Up to 32 events in each of the three categories will be kept in non-volatile memory. When the log is full, the oldest event will be overwritten. The most recent event will be displayed first. 1) Alarm Log Scroll through 32 Alarm Logs with time, date and temperature stamp. 2) Fault Log Scroll through 32 Fault Logs with time, date and temperature stamp. 3) General Log Scroll through 32 General Logs with time, date and temperature stamp. Page 20

Command Menu 17. Command Menu The Command Menu allows the operator to initiate a manual Oi test and also to perform various reset/clear functions. 1) Start Passive Oi A passive Oi test command checks the cleanliness of the detector s optical surfaces. This confirms the ability of the detector to respond correctly to an IR signal. Fire and fault relays as well as 4 to 20 ma current loop output are unaffected by this test. A red LED signals a successful test, and an amber LED signals a failed test. The event log will indicate either Man Oi Pass or Man Oi Flt. 2) Start Active Oi CAUTION An active Oi test generates an actual Fire Alarm Output. All fire response equipment must be bypassed/disabled prior to testing to prevent unwanted output actuation. An active Oi test performs an Oi test with all detector outputs fully operational. Fire and fault relays as well as the 4-20mA loop are live. If the test is successful: Fire relay = Alarm. Fault relay = no fault. Current output is 20 ma. LED turns red. General log indicates Man Oi Pass. If the test is unsuccessful: Fire relay = No Alarm. Fault relay = Fault. Current output is 2 ma. LED turns amber. Fault log indicates Man Oi Flt. 3) Clear Oi Fault If the cause of the fault has not been corrected, subsequent Oi faults will occur. 4) Reset Latches Latching relays are reset and LED turns green. 5) Master Reset This function re-initializes the microprocessor, resets the operating software, and initiates a hardware reset for both the sensor and the HART interface. Latched relays are reset. 6) Clear Data Log This function resets the HART data log history. To view the logs, go to Device Info Menu and select History Menu. 7) HART Command Menu This menu performs various diagnostic and/or service functions. Page 21

HART CMD Menu 18. HART CMD Menu The HART CMD (Command) Menu allows the operator to perform diagnostic and service functions as follows: 1) Self Test Internal tests are performed and any detected problems are reported in Status Info. 2) Master Reset This function re-initializes the microprocessor, resets the operating software, and initiates a hardware reset for both the sensor and the HART interface. Latched relays are reset. 3) Loop Test This test allows the operator to manually set the analog signal output (4 to 20 ma) to a fixed user defined value. 19. Device Setup Menu This menu allows various setup, configuration and calibration functions. When Write Protect is off, these menus allow the operator to reconfigure or write new variables to the device. 1) Configuration Menu 2) Calibration Menu 3) Write Protect 4) HART Setup 5) Set Real Time Clock Refer to the appropriate sub-menus for details. Page 22

Configuration Menu 20. Configuration Menu 1) Edit Cons Oi Fails This option allows the operator to select the number of consecutive Oi failures before an Oi fault will be generated. Selectable range is 1 to 1000. 2) Edit Temp Setpoint This option allows the operator to select the temperature at which the optics heater begins operating. 3) Edit Heater Setpoint This option allows the operator to select the maximum amount of heater power allowed, in percent of full power. (0% = heater shut off.) 21. Calibration Menu 1) Loop Test This test allows the operator to manually set the analog signal output (4 to 20 ma) to a fixed user defined value. 2) D/A Trim This function allows adjustment of the 4 to 20 ma span factor. 3) Calibrate Oi This procedure calibrates the Oi test signal for all three IR sensors. 1. Bypass/disable all Alarm outputs connected to the detector. 2. Thoroughly clean the sensor and Oi reflector for each of the three sensors. Check each of the three Oi source openings for contaminants and clean as needed. 3. Cover the detector with the provided cover. 4. Initiate Oi Calibration. The detector performs the calibration automatically and notifies the operator upon completion. The procedure takes approximately two minutes. 5. Upon completion of Oi calibration, remove the cover and return all alarm outputs to service. Page 23

Write Protect 22. Write Protect This function enables the operator to enable/disable password and write protection capability, as well as to enter or change a password. The device is provided from the factory with Write Protect off. With Write Protect on, the use of a password is required to enable writing to the device. 1) Set Password The password is used to validate the command to enable or disable writes in the device. (The factory default password is: 1*******. Once the password has been changed, the default password is no longer valid.) CAUTION Always record the new password. If the password is forgotten, the device must be returned to the factory for re-programming. 2) Set Write Protect With Write Protect On, variables cannot be written to the device and commands that cause actions to be performed in the device cannot occur. 3) Write Protect (Y/N) This indicates whether or not Write Protect is enabled. Page 24

HART Setup 23. HART Setup This menu allows editing of the following functions: 1) Polling Address Address used by the host device to identify a field device. 2) Final Asmbly No. A number that is used for identification purposes, and is associated with the overall field device. 3) Tag Text that is associated with the field device installation. This text can be used by the operator in any way. 4) Date Any date chosen by the operator to be used for any purpose. 5) Descriptor Text associated with the field device that can be used by the operator in any way. 6) Message Text associated with the field device that can be used by the operator in any way. 24. Set Real Time Clock To set the real time clock, enter the current time and date information into the appropriate fields. 1) Seconds 0 to 59. 2) Minutes 0 to 59. 3) Hours 0 to 23. 4) Date 1 to 31. 5) Month 1 to 12. 6) Year 0 to 99. Page 25

Set Real Time Clock Page 26

Reader s comments 25. Reader s comments Please help us to improve the quality of our documentation by returning your comments on this manual: Title: Addendum, AutroFlame X33AF Ref. No.: 116-P-X33AFADDENDUM/YGB, DEC P/N 95-8624, 2007-11-12 Your information on any inaccuracies or omissions (with page reference): Please turn the page

Reader s comments Suggestions for improvements Thank you! We will investigate your comments promptly. Would you like a written reply? θ Yes θ No Name: ------------------------------------------------------------------------------------------------ Title: ------------------------------------------------------------------------------------------------ Company: ------------------------------------------------------------------------------------------------ Address: ------------------------------------------------------------------------------------------------ ------------------------------------------------------------------------------------------------ ------------------------------------------------------------------------------------------------ Telephone: ------------------------------------------------------------------------------------------------ Fax: ------------------------------------------------------------------------------------------------ Date: ------------------------------------------------------------------------------------------------ Please send this form to: Autronica Fire and Security AS N-7483 Trondheim Norway Tel: + 47 73 58 25 00 Fax: + 47 73 58 25 01 www.autronicafire.com

Reader s comments

Autronica Fire and Security is an international company, headquartered in Trondheim, one of the largest cities in Norway. The company is owned by United Technologies Corporation and employs more than 319 persons with experience in developing, manufacturing and marketing of fire safety equipment. Our products cover a broad range of systems for integrated solutions, including fire detection systems, integrated fire and gas detection systems, control and presentation systems, voice alarm systems, public address systems, emergency light systems, plus suppression systems. All products are easily adaptable to a wide variety of applications, among others, hospitals, airports, churches and schools, as well as to heavy industry and high-risk applications such as power plants, computer sites and offshore installations, worldwide. The company's strategy and philosophy is plainly manifested in the business idea: Protecting life, environment and property. Quality Assurance Stringent control throughout Autronica Fire and Security assures the excellence of our products and services. Our products are CE marked and developed for worldwide standards and regulations, and conform to the CEN regulation EN54. Our quality system conforms to the Quality System Standard NS-EN ISO 9001:2000 and is valid for the following product and service ranges: marketing, sales, development, engineering, manufacture, installation, commissioning and servicing of suppression, integrated fire and gas detection and alarm systems, plus petrochemical, oil and gas instrumentation systems for monitoring and control. Autronica Fire and Security AS Headquarters, Trondheim, Norway. Phone: + 47 73 58 25 00, fax: + 47 73 58 25 01. Head Office Oil & Gas, Stavanger, Norway. Phone: + 47 51 84 09 00, fax: + 47 51 84 09 99. Division Oil & Gas, Oslo, Norway. Phone: + 47 23 17 50 50, Fax: + 47 23 17 50 51 Division Oil & Gas, PO Box 416, Farnborough GU14 4AT, UK. Phone: + 47 51 84 09 00, Fax: + 44 84 52 80 20 55 Division Maritime, Suppression/New Build Detection & Alarm. Norway. Phone: + 47 31 29 55 00, Fax: + 47 31 29 55 01 Division Maritime, After Sales/Service Detection & Alarm, Norway. Phone: +47-73 58 25 00, Fax: +47-73 58 25 01 Visit Autronica Fire and Security's Web site: www.autronicafire.com