SECTION ONE - CHEMICAL - TANK VENTING

Similar documents
Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

SECTION METERS AND GAGES FOR PLUMBING PIPING

SECTION STEAM CONDENSATE PUMPS

Diesel Exhaust Fluid Compatible Products DEF

Used Fluid Handling Portable Used Oil Gravity Drains

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

SECTION METERS AND GAGES FOR HVAC PIPING

WAL-RICH CORPORATION SINCE 1950

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service

A. This Section includes the following domestic water piping specialties:

Sheet Ref. CSCONTENTS May Revision 0

NOTE: Parts are no longer available for this tool. The manual will continue on the next page.

OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F

Audi-Larm Audible Alarm

Refrigerant Valves/Accessories

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

SECTION SECTION DESIGN REQUIREMENTS

Series 1140 and 1141 Temperature Regulators

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

SECTION HEATING BOILER FEEDWATER EQUIPMENT

SPRINKLERS TABLE OF CONTENTS

MODEL CMA-180UC PARTS MANUAL Rev 1.16

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

SECTION FIRE PROTECTION

TANKER & STORAGE TANK PRODUCTS

IMAGE V. Parts and Service Manual

General System Layout Sketch

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

SECTION AUTOMATIC SPRINKLER PIPING

Installation and Operation of AST Equipment. Presenter: Steve Allwein Northeast Regional Sales Manager Morrison Bros. Co.

SECTION DOMESTIC WATER PIPING SPECIALTIES

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

TECHNICAL DATA. Wet 26a. February 22, 2009

Used Fluid Handling Portable Used-Oil Gravity Drains

MODEL CMA-180UC PARTS MANUAL Rev 1.18

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

YALE Site Specifications AIR VENT SCHEDULE

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

Heat Exchanger Block Replacement Instructions

INSTALLATION, OPERATION

Troubleshooting the MPH 24FP Series Pedestal Hydrant

University of Delaware

Marley Ultra Quiet Fan

REPLACEMENT PARTS MANUAL FOR MODEL: PWS 45-75, AED-2 & APK-4 SERIES

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

568X, 587X, 588X Series

THE THOMPSON MODEL A STEAMER NEW UNIT ASSEMBLY INSTRUCTIONS

Twin-Agent Fire Fighting/Securing Systems Specifications

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

13-1. Temperature Regulator

Division 23 - HVAC Switzerland Beallsville K-12. Section HYDRONIC PIPING SECTION HYDRONIC PIPING PART 1 - GENERAL

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

ISO9001:2008 Cert Certified FIRE HYDRANTS. since SFFECO

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

VACUUM VALVES AND HOSES

Section H11 BLOWDOWN SEPARATORS CONTENTS FEATURES AND BENEFITS...H11-3 PRODUCT OFFERING...H11-3 SAMPLE SPECIFICATIONS...H11-11 ILLUSTRATIONS

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

REF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

Lasco # Description Picture Lasco # Description Picture

SECTION BASIC MATERIALS AND METHODS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.

MARK-COSTELLO WASTE STERILIZER SPECIFICATION SHEET

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

Protected with TechCoat finish. For Ceramic Tile Showers Cast iron Threaded for test nipple Extra heavy (.050) strainer DRAIN CONNECTION

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section

569, 570, 571, 572 Series

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Technical Data. Sizes: ANSI Inches (DN) 2-1/2 (DN65), 3 (DN80), 4 (DN100), 5 (DN125), 6 (DN150), 8 (DN200), 10 (DN250)

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B

MIRAI EXTRACTOR 100V DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

Discontinued Product

SECTION SPRINKLER SYSTEMS

Instructions for Installation, Operation, Care and Maintenance

Design and Construction Standards SECTION PLUMBING EQUIPMENT


B. Related Sections: The following Sections contain requirements that relate to this Section.

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

INFINITY FLUIDS CORPORATION

Lubrication Tools and Equipment Portable Oil Drains

HOT WATER BOILER ( MBH)

CLOSED COUPLED CENTRIFUGAL PUMPS

FLO-RITE-TEMP INSTANTANEOUS WATER HEATER INSTALLATION AND ADJUSTMENT INSTRUCTIONS FOR SINGLE AND DOUBLE WALL UNITS

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

GALATEA DOMUS. Dal 1901 COD

WASHER & DRYER REPAIR

Transcription:

GIRARD EQUIPMENT DOT-407 VENT Part Number # GIR-DOT407LT25 The last two digits specify pressure setting. Girard Equipment s DOT-407 vent is a stainless steel, pressure actuated unit that is engineered to limit excessive internal pressure to the tank test pressure. The flow rate of the vent is large enough to provide all the required pressure relief of virtually every DOT-407, DOT-412, MC-307, or MC-312 tank. Equipped with teflon encapsulated o- rings, these vents offer a bubble-tight seal with complete chemical resistance. The entire vent is designed to be easily removed from the tank vehicle for inspection and/or cleaning. The vent is available with different connection options as well as pressure settings. SECTION ONE - CHEMICAL - TANK VENTING 1-1

TANK VENTING - CHEMICAL - SECTION ONE GIRARD EQUIPMENT 3 DOT-407 RETROFIT VENT Girard Equipment, Inc. s three inch DOT 407 vents allow you to upgrade virtually any MC307, for MC312 tank trailer to DOT407, or DOT412 venting. All the benefits of the 400 series vents are yours without expensive hot-work. Flow rates are slightly less than standard 4 DOT407 vents, but are more than sufficient for most tank trailers. See table below for specific flow rates. The stainless steel valve seat seals on a Teflon encapsulated silicon O ring. This o ring provides complete chemical resistance and a bubble tight seal to meet the latest DOT requirements. The unit also meet the surge requirements of 178.345-10 (b) (3). The three inch vent is designed to be easily removed from the tank for inspection and/or cleaning. PART NUMBER & PERFORMANCE SPECIFICATIONS PART NUMBER MAWP TEST FLOW EXPOSED PRES. (SCFH) SURFACE GIR-DOT3X407T-25 25 40 372,844 732 25 45 408,485 860 GIR-DOT3X407T-30 30 45 408,485 860 GIR-DOT3X407T-35 35 52.5 460,433 1061 ITEM # PART # DESCRIPTION 1 GIR-402003L RAIN COVER 2 GIR-402004L LOW PROFILE UPPER HOUSING, SPECIFY PRESSURE SETTING 3 GIR-402005 PRESSURE SPRING 4 GIR-402006L LOW PROFILE POPPET 5 GIR-402007 TEF-O-SIL O-RING 6 GIR-402018 3 T MODEL LOWER HOUSING 7 GIR-3TOR SOLID PTFE O-RING 8 GIR-402020 3 F MODEL LOWER HOUSING 9 GSK-RGA301TF 3 TTMA PTFE ENVELOPE FLANGE GASKET 10 GIR-402021 3 AF MODEL LOWER HOUSING 11 GIR-402022 TEFLON ENVELOPE ANSI FLANGE GASKET 1-2

GIRARD EQUIPMENT DOT 412 VENTS PART NUMBER: GIR-DOT3X407AFTL 3 ANSI FLANGED VENT TEFLON LINED ASK ABOUT RETROFITTING UNLINED VENTS WITH A TEFLON LINER. PART NUMBER: GIR-DOT407LAFTL 4 ANSI FLANGED VENT TEFLON LINED NO NEED FOR RUPTURE DISCS SECTION ONE - CHEMICAL - TANK VENTING 1-3

TANK VENTING - CHEMICAL - SECTION ONE 1-4

SECTION ONE - CHEMICAL - TANK VENTING 1-5

TANK VENTING - CHEMICAL - SECTION ONE FUNCTION The new ultra low-profile Magnetic Vacuum Breaker is a valve design to limit negative pressure (vacuum) in a typical tank trailer. The unit employs the already popular New Generation design, which can be disassembled, cleaned and repaired without the need for special tools. A permanent magnetic force controls the movement of the valve poppet caused by road vibration to open only on demand of 4 Hg or greater. All working parts are kept away from the airflow paths, which promotes easy cleaning and hassle free repairs. This model has a 3 NPS swivel connection and stands less than 4 when installed ona typical tank nozzle making it easy to install under already existing overturn protection. Customers interested in purchasing the older MC307 style 3MVB should consider this new model, which is lower in cost and will provide an increased flow rate over the 3MVB. 1-6

SECTION ONE - CHEMICAL - TANK VENTING 1-7

TANK VENTING - CHEMICAL - SECTION ONE GIRARD EQUIPMENT DOT-407 VACUUM VENT ASSEMBLY PART NUMBERS PART NUMBER GIR-407MVBTT GIR-407MVBFT GIR-407MVBST GIR-407MVBMT STYLE THREADED, TEF-O-SIL SEAT FLANGED, TEF-O-SIL SEAT STRAIGHT STUB END, TEF-O-SIL SEAT 18 DEGREE STUB END, TEF-O-SIL SEAT Discontinued Parts still available (SUBSTITUTE K FOR T IN PART # FOR KALREZ SEAT) ITEM # PART # DESCRIPTION 1 GIR-401001 V/B CAP 2 GIR-401002EP RAIN COVER 3 GIR-401017 LOCK RING 4 GIR-401004 UPPER BUSHING 5 GIR-401005 RETAINING RING 6 GIR-401006S CONICAL SPRING 7 GIR-401008 LOWER BUSHING 8 GIR-401009 WIPER 9 GIR-401010-O POPPET,KALREZ/TEF-O-SIL 10 GIR-401011TS TEF-O-SIL O-RING 11 GIR-401011-KO KALREZ O-RING 12 GIR-401012M HOUSING, M-MODEL 13 GIR-401012S HOUSING, S-MODEL 14 GIR-401012B HOUSING, T-MODEL 15 GSK-4TRX SOLID PTFE GASKET 16 GIR-401012F HOUSING, F-MODEL 17 GSK-RGA401TF 4 PTFE ENVELOPE FLANGE GASKET Discontinued. Parts available only. For the latest style, please refer to the New Generation DOT 407 Magnetic Vacuum Breaker vents. 1-8

GIRARD EQUIPMENT 3 PRESSURE VENT Vent assembly part numbers: The Girard Equipment MC-307 vent is a stainless steel pressure actuated unit that is engineered to limit excessive internal pressure to 130 percent of tank design. The standard model vent set at 25 PSIG will exhaust 26,700 SCFH at 32.5 PSIG and conforms to the emergency venting requirement code for a spring loaded device that is used of MC-307 transports having a total exposed surface area of 700 square feet. Equipped with Kalrez seals, this vent offers a bubble-tight seal with chemical resistance of teflon. Rating Part Number Style 25,30,35 GIR-MC307BLV## Threaded (Specify Setting) 25,30,35 GIR-MC307FLV## Flanged (Specify Setting) 25,30,35 GIR-MC307MLV## 18 degree (Specify Setting) 25,30,35 GIR-MC307SLV## Str. stub (Specify Setting) Part number identification: Key # Part Number Description 1 GIR-202001 Rain Cover Bolt 2 GIR-202002-## Rating Disc (Specify Setting) 3 GIR-202003-1 Rain Cover, low profile 4 GIR-202004-1 Upper Housing, low profile 5 GIR-202005 Pressure Spring 6* GIR-202030 Wave Ring 7* GIR-202031 Upper Spring Retainer 8* GIR-202032 Teflon Back-Up Gasket 9* GIR-202033 Kalrez Valve Seat 10* GIR-202034 Male Spring Retainer 11 GIR-202011-## Lower Housing, Thd Model 11A GIR-202011A-## Lower Housing, Str. Stub Model 11B GIR-202011B-## Lower Housing, 18 Degree Mod. 12 GIR-202012 Swivel Nut 13 GSK-3TR 3" PTFE Gasket 14 GIR-202014-## Lower Housing, Flanged Model 15 GSK-RGA301TF 3" TTMA PTFE Env. Gasket * GIR-VSK5 Valve seat kit, Inc. items 6-10 ** GIR-VSK5V Valve seat kit w/vacuum poppet SECTION ONE - CHEMICAL - TANK VENTING 1-9

TANK VENTING - CHEMICAL - SECTION ONE 1-10

New Design Girard MC307 Pressure Relief Vent Parts Illustration SECTION ONE - CHEMICAL - TANK VENTING 1-11

TANK VENTING - CHEMICAL - SECTION ONE GIRARD EQUIPMENT 3 PRESSURE/VACUUM VENT Girard Equipment, Inc. s PV300 Pressure Relief Vent is engineered to limit excessive internal tank pressure to 130 percent of tank design. The standard model vent set at 25 PSIG will exhaust 26,700 SCFH at 32.5 PSIG. A small vacuum section is included, but due to it s limited size, should not be relied upon to provide adequate vacuum protection. Vent assembly part numbers: Rating Part Number Style 25,30,35 GIR-PV300BLV## Threaded (Specify Setting) 25,30,35 GIR-PV300FLV## Flanged (Specify Setting) 25,30,35 GIR-PV300MLV## 18 degree (Specify Setting) 25,30,35 GIR-PV300SLV## Str. stub (Specify Setting) Part number identification: Key # Part Number Description 1 GIR-202001 Rain Cover Bolt 2 GIR-202002-## Rating Disc (Specify Setting) 3 GIR-202003 Rain Cover 4 GIR-202004 Upper Housing 5 GIR-202005 Pressure Spring 6* GIR-202006 Spring Retainer 7* GIR-202007 Teflon Valve Seat w/vacuum 8* GSK-202008 Hypalon Gasket 9* GIR-202009 Vacuum Ball 10* GIR-202010 Vacuum Spring 11 GIR-202011A-## Lower Housing, Str. Stub Model 12 GIR-202011-## Lower Housing,Thd. Model 13 GIR-202012 Swivel Nut 14 GSK-3TR 3 PTFE Gasket 15 GIR-202014-## Lower Housing, Flanged Model 16 GSK-RGA301tf 3 TTMA PTFE Env. Gasket * GIR-PVS1 Valve seat kit, Inc. items 6-10 1-12

GIRARD EQUIPMENT 3 VACUUM VENT Key # Part Number Description 1 GIR-202001 Rain Cover Bolt 2 GIR-201002 Rating Disc 3 GIR-201003 Rain Cover 4 GIR-201004 Upper Housing 5a GIR-201005 Valve Housing, Kalrez 5b GIR-201005T Valve Housing, Tef/Sil 6a GSK-201006 PTFE Gasket 6b GIR-201006TS Tef-O-Sil O-ring Gasket 7 GIR-201007-1 Lower Housing, Str.Stub 7a GIR-201007-2 Lower Housing, 18* Stub (Not Shown) 8 GIR-201008 Lower Housing, Flanged 8a GSK-RGA301TF 3 TTMA PTFE Env. Gasket 9 GIR-201007 Lower Housing, Threaded 9a GIR-202012 Swivel Nut 9b GSK-3TR PTFE Gasket SECTION ONE - CHEMICAL - TANK VENTING 1-13

TANK VENTING - CHEMICAL - SECTION ONE 1-14

GENUINE GIRARD VENT SERVICE KITS GIR-PVS1 VENT SERVICE KIT FOR 3 PRESSURE VACUUM VENT GIR-PVS3 VENT SERVICE KIT FOR 3 PRESSURE VENT GIR-PVS4 VENT SERVICE KIT FOR 3 PRESSURE VENT WITH GIR-202020B REPLACEABLE TEFLON SEAT GIR-VSK5V 3 PRESSURE/VACUUM VENT SEAT, KALREZ GIR-VSK5 3 PRESSURE VENT SEAT, KALREZ GIR-201005T 3 VACUUM BREAKER CAGE ASSEMBLY SECTION ONE - CHEMICAL - TANK VENTING 1-15

FUSIBLE CAPS - CHEMICAL - SECTION ONE GIRARD FUSIBLE CAPS Girard Equipment Inc. s fusible caps are tested and marked in accordance with DOT MC306 and MC307 requirements. Fusible metal is placed in an area not in contact with tank lading and sealed by a gasket. Each cap is hydrostatically tested to 75 PSIG on a faced IPT nipple for insurance against leakage in casting or fusible metal. Part Number GIR-3SF GIR-4SF 3 Stainless Steel 4 Stainless Steel GIRARD 3 S/S-POLYMER FUSIBLE CAP Girard Equipment Inc. s new 3 fusible cap is manufactured in accordance with C.F.R.178.342-4 for use on MC307 Tank Trailers. A chemically inert thermoplastic polymer is used to join the two-piece cap together. Manufactured from heavy-duty castings, excessive wrenching will neither distort, or damage the fusible material. Part Number GIR-3SPF 1-16

GIR-MC307TC 3 PRESSURE VENT TEST CAP GIRARD SOLID CAPS Part Number GIR-3SC GIR-4SC GIR-3AC GIR-4AC 3 Stainless Steel 4 Stainless Steel 3 Aluminum 4 Aluminum GIRARD 3 S/S RING BOSS CAP Part Number GIR-3SC-RB TEST CAPS FOR GIRARD MC 307 STYLE VENTS GIR-3MVBTC 3 VACUUM VENT TEST CAP SECTION ONE - CHEMICAL - PIPE CAPS 1-17

VAPOR VENTING - CHEMICAL - SECTION ONE 1-18

FORT VALE VAPOR RECOVERY VENT This Fort Vale vapor recovery vent is manufactured in 316 stainless steel with all welds fully homogeneous to ASME design requirements. Standard finish is a high commercial quality electropolish or machine finish. The vent is designed to provide automatic vacuum relief when the discharge valve is opened. The hydraulic activator opens both the Chemical Hydraulic valve and the Vapor Recovery Vent consecutively; with the Recovery Vent opening prior to the Chemical Hydraulic valve. PART NUMBER FOR-57/10030 SECTION ONE - CHEMICAL - VAPOR VENTING 1-19

VAPOR VENTING - CHEMICAL - SECTION ONE 1-20

SECTION ONE - CHEMICAL - VAPOR VENTING 1-21

TANK VENTING - CHEMICAL - SECTION ONE HYDROSEAL SAFETY RELIEF VALVES PART NUMBER PRESSURE & SIZES HYD-1CXV30-35 35 PSI, 1/2 X 3/4 HYD-3CXV30-35 35 PSI, 3/4 X 3/4 HYD-3XCV30-50 50 PSI, 3/4 X 3/4 SARCO STEAM TRAP PART NUMBER STEAM PANEL RELIEF VALVES PART NUMBER PRESSURE & SIZES PVA-14917 75PSI, 3/4 PVA-18277 75PSI, 1/2 PVA-19293 150PSI, 1/2 PVA-19294 150PSI, 3/4 SIZE SAR-54530 1/2 SAR-54531 3/4 SAR-54532 1 BARNES & JONES STEAM TRAP PART NUMBER SIZE BAR-2GW 1/2 BAR-3GW 3/4 1-22

BETTS CHEMICAL HYDRAULIC VALVE Betts Industries chemical hydraulic valve is designed for use with a wide variety of chemicals. A replaceable teflon seat and removable disc are provided for ease in repairing should damage occur from dirt or other foreign material. Indicator pins, which move in relation to the piston, show the position of the disc at all times. No shear section provided-for regulated products, protection should be provided by suitable guards as specified in DOT 178.340-8. Maximum working pressure is 50 psi. Maximum temperature is 365 degrees F. Part Number Size BET-CH45613SST 4 X 3 BET-CH45586SST 4 X 4 BET-CH45618SST 4 X 3 (Jacketed) SECTION ONE - CHEMICAL - TANK VALVES 1-23

TANK VALVES - CHEMICAL - SECTION ONE BETTS CHEMICAL INTERNAL HYDRAULIC VALVE The Betts Chemical Internal Hydraulic Valve is designed to be used for applications where a standard Chemical Hydraulic Valve would prove impractical. Elbow supplied with shear section. Part Number: BET-CH45843SST 1-24

BETTS HYDRAULIC VALVE ACCESSORIES BET-CH26165SST 4 X 3 90 DEGREE STANDARD ELBOW BET-CH26166SST 4 X 3 90 DEGREE STEAM JACKETED ELBOW BET-CH17827TF TEFLON REPAIR KIT FOR INTERNAL CHEMICAL HYDRAULIC VALVE BET-CH17828TF TEFLON REPAIR KIT FOR CHEMICAL HYDRAULIC VALVE BET-CH16859SST 4 X 4 90 DEGREE STANDARD ELBOW MOUNTING PAD FOR CHEMICAL HYDRAULIC VALVES BET-MP16914SS (2-7/8 STUD LENGTH) BET-MP16590SS (1-7/16 STUD LENGTH) BET-FP15003BR FUSIBLE PLUG BET-FP15017BR FUSIBLE/FRANGIBLE BREAKAWAY SECTION ONE - CHEMICAL - TANK VALVES 1-25

TANK VALVES - CHEMICAL - SECTION ONE BETTS QUICK CLEAN CHEMICAL HYDRAULIC VALVE The Betts Quick Clean Chemical Hydraulic Valves are designed to meet the exacting requirements of todays chemical transport industry. The valve features quick removable spring housing and hydraulic actuator units which provide for easy inspection and maintenance. Encapsulated silicone o-ring seals and the tapered seat provide positive sealing and product retention. An indicator rod shows whether the valve is open. Part Numbers: BET-CH46312SSTS 4 X 3 VALVE, 90 DEGREE ELBOW BET-CH46236SSTS 4 X 4 VALVE, 90 DEGREE ELBOW 1-26

BETTS HYDRAULIC PUMP The new Betts Hydraulic Pump has been designed to provide a trouble free, easily maintained pump for use with any Betts hydraulic operated valve. Pump is made of cast iron, has a stainless steel piston, replaceable release valve seat, and an internal pressure relief valve set to bypass at approximately 3000 psi. Part Number: BET-HP19165MS SECTION ONE - CHEMICAL - TANK VALVES 1-27

TANK VALVES - CHEMICAL - SECTION ONE BETTS QRB HYDROLET VALVES BET-QR713SST QRB VALVE, 3 90 DEGREE THREADED OUTLET CONSTRUCTED IN T316 STAINLESS. ALSO AVAILABLE IN 4 BET-QR703SST QRB VALVE, 3 90 DEGREE FLANGED OUTLET CONSTRUCTED IN T316 STAINLESS. ALSO AVAILABLE IN 4 BET-JQ713SST QRB VALVE, 3 90 DEGREE THREADED OUTLET, STEAM JACKETED CONSTRUCTED IN T316 STAINLESS. ALSO AVAILABLE IN 4 QRB HYDROLET VALVES AVAILABLE WITH DIFFERENT PIPING CONFIGURATIONS PLEASE CALL FOR PRICING AND AVAILABILITY 1-28

BETTS QRB HYDROLET VALVES OS & Y STYLE BET-QY46134SST Designed to mount directly to the Internal Chemical Hydraulic Valve. This valve has a 3 45 degree threaded outlet. BET-QY46136SST Designed to mount directly to the Internal Chemical Hydraulic Valve. This valve has a 3 45 degree threaded outlet, 13.5 long. BET-JY46130SST Designed to mount directly to the Internal Chemical Hydraulic Valve in the rear head of the tank. Flange is offset for least amount of product retention in the tank. SECTION ONE - CHEMICAL - TANK VALVES 1-29

TANK VALVES - CHEMICAL - SECTION ONE BETTS QRB HYDROLET VALVES PARTS LIST 1-30

BETTS EMERGENCY UNLOADING FIXTURE BET-EM46443SS This fixture is designed to make possible the emergency unloading of an overturned tank through a capped 3 cleanout without spillage of product. After clamping on the unloading fixture as described in the operational instruction sheet, cleanout cap can be removed within the fixture and with proper discharge lines hooked up unload product down to the level of the cleanout. SECTION ONE - CHEMICAL - TANK VALVES 1-31

TANK VALVES - CHEMICAL - SECTION ONE Flange by thread models Flange by flange models BETTS GATE VALVES 1-32

BETTS HYDRAULIC SLIDING GATE VALVES SECTION ONE - CHEMICAL - TANK VALVES 1-33

TANK VALVES - CHEMICAL - SECTION ONE BETTS MECHANICAL EMERGENCY VALVES 1-34

BETTS UNIVERSAL MECHANICAL OPERATORS SECTION ONE - CHEMICAL - TANK VALVES 1-35

TANK VALVES - CHEMICAL - SECTION ONE BETTS UNIVERSAL MECHANICAL OPERATORS PARTS LIST 1-36

CIVACON DRY DISCONNECT COUPLINGS VAPOR RECOVERY ADAPTOR PART NUMBER: CIV-2173AVN DRY DISCONNECT ADAPTOR PART NUMBER SIZE CIV-1673AN0150 1.5 CIV-1673AN0200 2 CIV-1673AN0300 3 ABOVE PART NUMBERS ARE FOR STAINLESS STEEL ADATORS. ALUMINUM ALSO AVAILABLE. DRY DISCONNECT COUPLER PART NUMBER SIZE CIV-1772D0300 1.5 CIV-1772D0300 2 CIV-1772D0300 3 ABOVE PART NUMBERS ARE FOR STAINLESS STEEL COU- PLERS WITH VITON SEALS. USE 1775 SERIES FOR CHEMRAZ SEALS. ALUMINUM ALSO AVAILABLE. SECTION ONE - CHEMICAL - TANK FITTINGS 1-37

TANK VALVES - CHEMICAL - SECTION ONE SEAL FAST, INC. DRY DISCONNECT COUPLINGS Seal Fast Inc. dry disconnect fittings are interchangeable with Civacon dry disconnect fittings. Part numbers SFI-673A-150 SFI-673A-200 SFI-771D-150 SFI-771D-200 1.5 STAINLESS STEEL ADAPTOR, TEFLON SEALS 2 STAINLESS STEEL ADAPTOR, TEFLON SEALS 1.5 STAINLESS STEEL COUPLER, TEFLON SEALS 2 STAINLESS STEEL COUPLER, TEFLON SEALS ALSO AVAILABLE IN ALUMINUM CONSTRUCTION AND A VARIETY OF SEALS. REPAIR KITS ALSO AVAILABLE. 1-38

UNIVERSAL AIR COUPLINGS SECTION ONE - CHEMICAL - TANK FITTINGS 1-39

TANK FITTINGS - CHEMICAL - SECTION ONE CAM AND GROOVE FITTINGS Available in various sizes and materials such as aluminum, brass, stainless steel, ductile iron, poly-glass and ny-glass 1-40

PRESSURE GAUGES & THERMOMETERS PGA-301L-254D LIQUID GAUGE PGA-301D-254D LESS DRY 0-60 ALL STAINLESS FILLED PRESSURE 0-60 ALL STAIN- PRESSURE GUAGE Many other sizes, ranges, and configurations available. Please call for your specific needs. PTH-BT500150 0-150 DEGREE THERMOMETER W/5 CAPILLARY TUBE PTH-BT500250 0-250 DEGREE THERMOMETER W/5 CAPILLARY TUBE PTH-BT500300 0-300 DEGREE THERMOMETER W/5 CAPILLARY TUBE SECTION ONE - CHEMICAL - GAUGES 1-41

MANHOLES - CHEMICAL - SECTION ONE BETTS 20 FULL OPENING MANHOLE (NON-ASME) MODEL NUMBER 8310 1-42

BETTS 20 FULL OPENING MANHOLE (ASME TYPE) MODEL NUMBER 8350 SECTION ONE - CHEMICAL - MANHOLES 1-43

MANHOLES - CHEMICAL - SECTION ONE 1-44

SECTION ONE - CHEMICAL - MANHOLES 1-45