ALARMLINE ANALOGUE Linear Heat Detection System

Similar documents
AlarmLine Linear Heat Detector

AlarmLine Addressable Linear Heat Detector

ALARMLINE ANALOGUE LINEAR TEMPERATURE DETECTION

Alarmline Linear Heat Detection

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Heat Sensor Cable Alarm Units DT650L / DT950L

"Alarmline LWM-1" System

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

Linear Heat Detection for Coal Conveyors. Application Guide

Tel: +44(0) Fax: +44(0) /17 LGM Products Ltd. Web: ISO 9001:2015 certified

"Alarmline LWM-1" System

STOCKIST OF LINEAR HEAT SESNING CABLE in INDIA

Alarmline II Analogue Linear Heat Sensor Cable Technical Manual

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

FIRE AND SAFETY. Manual Call Points p15-1 Magnetic Door Holders p15-3 Detection Cables p15-4 Portable Signals p15-7 Solar Powered Signals p

Linear Heat Detection Cable - Monitor

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

Alarmline II Digital Linear Heat Sensor Cable Technical Manual

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection

ThermoCable Linear Heat Detection System

DiMM Unit. LST Digital Interface Monitor Module (LST-DiMM) MAN3109

LINEAR HEAT SENSING DETECTION. System Sensor India 2014

LDM-519-DIM LHDC MONITOR Digital Line Heat Detector Interface

Interface Modules for SENTRI

Mobrey ultrasonic Liquid level detection systems

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Linear Heat Detection

IFD-E Flame Detector User Manual

LEAKSTOPPER RANGE Multizone water leak detection systems

Rules for Intruder Alarm Systems

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

Bimetal Disc Thermostat. Product Information and Application Notes

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

DCS-100. intelligent damper control & monitoring system

Fire & Security Products. Siemens Building Technologies Group

System 800 Addressable Fire Detection & Alarm System

LEAKSTOPPER 1 Single zone water leak detection system

Gas ventilation monitoring and control system

IFD-E Flame Detector User Manual

Low Temperature Zirconia Oxygen Analyzer

Installing Protectowire Linear Heat Detector

FireSystems PROTECTOWIRE. Installing Protectowire Linear Heat Detector

The EN54 Part 2 and 4 Fire System

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

Installation and Operation Manual

HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

DICTATOR Hold-Open Systems for Hazardous Areas

SOUNDER CONTROL MODULE SCM-AS4

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

RE-PR3-E-27 3-Phase Panel Mount 27kW

Hazardous Area Zirconia Oxygen Systems

Series 65 Product Guide MAN 3036

Installation, Operating and Maintenance Manual

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Dissolved Oxygen Analyzers

Intelligent Security & Fire Ltd

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

DAWN Electronics, Inc.

Model 5610 Infra-red Transit Heat Sensor

C-Bus Four Channel Analogue Output Unit Installation Instructions

Fill Point, Level Gauges, and Control Range

Flame Detector User Manual

Design Guide Design Notes Design Examples Technical Data Sheets Expanded Capabilities Specifications Warranty

Intelligent addressable fire alarm control panel

Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Danfoss gas detection unit Type GD Heavy Duty

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

Basic Vehicle Fire Protection Manual

BA334D Intrinsically safe Externally powered pulse input field mounting rate totaliser Issue 13

3 T828 Initial Adjustment

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities.

Dräger Flame 2500 (IR3) Flame Detection

Instructions AutroFlame IR Flame Detector BG-201/BG-21

DB5 Intrinsically Safe Sounder Type DB-5

LC2200 Level Controller Installation and Maintenance Instructions

BA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13

Instruction Manual August sitrans CU 02

Gas cylinder scale Model GCS-1

F1202 TRACE HEATING. Road & Ramp

Data Sheet. Self regulating process heating tapes RS stock numbers ,

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

TXgard-Plus. Flameproof Toxic and Oxygen Gas Detector with Non-intrusive One-man Calibration. Installation, Operation and Maintenance Instructions

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

URD20SE. Gas detectors Carbon dioxide (CO 2 ) ATEX certified (II 2G Ex d IIC T6) Use. Operation. Ordering

XP95 Sounder VAD Base

Line Smoke Detector LRMX

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

Movement Detector GJD 300

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

DETECT-A-FIRE Heat Detectors

Reflective Optical Beam Smoke Detector User Guide

Transcription:

ALARMLINE ANALOGUE Linear Heat Detection System Alarmline Analogue cable senses temperature variations by continuously monitoring the resistance of specially doped Negative Temperature Coefficient (N.T.C.) polymeric insulation. A change in temperature produces a relative change in resistance between the two loops within the sensor cable as temperature increases, resistance is lowered. This change is monitored by an Alarmline LHD4 control unit, which actuates an alarm signal at a pre-determined level. The integrating effect of Alarmline sensor cable enables it to detect either a hot spot or a lower level of temperature increase over its total length. Provided the sensor cable has not been directly subjected to temperatures greater than 120 C for excessive periods, it will recover to an alert condition after activating an alarm. Upon destruction, Alarmline fails permanently into the alarm state. Benefits Flexible in installation Recoverable after operation Monitors precise point of risk Sensitive to small temperature variations Mechanical/environmental protection options Approvals Vds (via Kidde Deugra) FM Global FM.0M3A0.AY and FM.OR5A4.AY Chinese Approval (Shenyang) Alarmline analogue sensor cables are approved for use by UK Power Generation Industry (formerly CEGB) Approval and Distribution Authorities under their Reference: EPA215 High Resistance Sensor Alarmline Analogue sensor consists of a 4-core cable. Two of the four colourcoded conductors are insulated with a Negative Temperature Coefficient (NTC) material. The other two conductors have normal PVC insulation. The cores are twisted together and protected by an outer sheath of high temperature, flameretardant PVC insulation (see Fig. 1). Applications Rack storage Escalators Cable trays Conveyors Floating roof tanks Covered car parks

2 At one end of the sensor cable, the four conductors are connected to an Alarmline LHD4 control unit (optionally via a junction box). At the outer end, the conductors are joined and hermetically sealed to form two loops (see Figs. 2a and 2b). Both loops are continuously monitored for open and short circuit faults. A breakage or disconnection of either loop initiates a fault signal in the control unit. Fig. 1 Fig. 2a BLUE RED RED BLUE Negative Temperature Coefficient Material Sensor Conductor Wire Protective Insulation High Temperature PVC 4 CONTINUITY MONITORING 3 RESISTANCE (TEMPERATURE) SENSING Extra mechanical or environmental protection can be provided by the addition of a nylon coating or bronze braiding. ORANGE Fig. 2b WHITE WHITE ORANGE 2 CONTINUITY MONITORING 1 System Design The maximum ambient temperature must be identified. This depends on climatic and working conditions. Two other variables must be established: 1. The maximum length of sensor cable to be employed in the risk area 2. The calibration resistance to be set at the LHD4 control unit. When the maximum length has been selected, the calibration resistance can be identified using the Nomogram, and the corresponding alarm temperature identified. Design lengths must take into consideration the most likely exposure under identified overheat or fire risks. Using the Nomogram When Alarmline Analogue cable is installed, the calibration switch setting on the LHD4 control unit must be set to suit the conditions of the installation. This setting is determined using the Nomogram (Fig 3) as in the following example: 1. On Scale D, mark the sensor cable length in the risk area (100 metres in this example). 2. On Scale B, mark the maximum ambient temperature allowed, which must not give an alarm (45 C). 3. Draw a line from the mark on Scale D, through the mark on Scale B, to Scale A. The point at which the line intercepts Scale A will show the correct calibration switch setting (6). This is the switch setting that will not cause a false alarm at the maximum ambient temperature of 45 C. The point where the line crosses Scale C indicates the temperature required along the entire cable length to give an alarm (57.5 C). If a hot spot were to occur anywhere along the cable length, the Nomogram will indicate how hot this would need to be to give an alarm. For a 10 metre hot spot, take a line from the 10 metre mark on Scale D to switch setting 6 on Scale A. The temperature required to give an alarm from a 10 metre hot spot can then be read on Scale C (84 C) Similarly, a 2.5 metre hot spot would require a temperature of 103 C to alarm.

3 Fig. 3 HIGH RESISTANCE SENSOR NOMOGRAM (FOR SERIES 4 LHD TYPE T CABLE ONLY) A B C D Example Switch Setting Hot Spot Examples Calibration Link setting Max ambient temp ( C) by which an alarm will not be given Specified alarm temp ( C) by which an alarm will be given Cable length (m) Ordering Data Alarmline sensor cable is supplied on terminated reels (in multiples of 100 metres). High Resistance (blue) K82017 High Resistance Nylon coated (black) K82021 High Resistance Bronze Braid K82078 Nylon over stainless steel braid K98166 In-line jointing kit (pack of 10) K82024 End-of-line termination kit (pack of 10) K82023

4 Alarmline Analogue Cable Technical Specification Part Number External Diameter (nominal) Weight (200 m) Minimum Tensile Strength Conductor Diameter Dielectric Thickness Outer Sheath Thickness Twist Turns of Inner Conductors Conductor Material Insulation Core Colours Service Life Voltage Proof PVC (blue) K82017 3.25 mm 3.2 kg 100 N Nylon coated (black) K82021 4.25 mm 4.3 kg +100 N Bronze Braid K82078 4.25 mm 8.3 kg 1000 N 0.46 mm 0.34 mm 0.25 mm 90 ±5 per m Copper Cores 2 and 4: Specially Doped NTC Polymer, Cores 1 and 3: PVC 1: Orange, 2: White, 3: Red, 4: Blue Up to 100 C: Unlimited 10 kv between outer sheath and a conductor Nylon + Stainless Steel Braid K98166 5 6 mm 10 kg 1000 N LHD4 Control Unit Alarmline Analogue cable must be used in conjunction with a Series 4 LHD Control Unit (Fig. 4). The electronic unit is housed within a IP55 rated polycarbonate enclosure, with a hinged transparent lid. Important Note Before connecting conductors 1 (orange) and 3 (red) to the LHD Unit, the polyester enamelling on the copper cores MUST be removed by scraping with a knife at both ends of the cable. This will ensure a good electrical connection. Benefits Sensor cable monitoring by highly stable and sensitive electronics 2-wire operation fully compatible with control and indicating control panels Fault relay energised or deenergised. Please specify when ordering Monitors Alarmline cable for open circuit and short circuit fault conditions Optional fire and fault relay output Fully monitored for internal fault conditions Can be used with BASEEFA approved Zener Barriers in all gas groups Wide operating voltage range Fig. 4 Alarmline LHD4 Control Unit

5 Alarmline LHD4 Control Unit Technical Specification Enclosure (for connection to a conventional system) Supply Voltage Quiescent Current Consumption Polycarbonate IP55 rated 170H x 105W x 111D Colour RAL 7035 Weight 0.55 Kg 8 to 30 VDC 60 to 180µA depending upon alarm trip setting Fire Alarm Current Consumption 15 to 70mA, pre-set by means of internal resistor (see note 1) Fault Alarm Current Consumption 180µA maximum Series 4 LHD with Relays (for connection to an analogue addressable system) Quiescent Current Consumption Fire Alarm Current Consumption Fault Alarm Current Consumption Radio Interference Susceptibility 20mA 85mA 16mA Will withstand 5% rms 50Hz supply voltage noise, and 1Vrms sensor noise with negligible performance change. RFI immunity at 10V/metre field strength over band 20-500MHz. For abnormally high operating levels of RFI/EMI (as in power/instrumentation cable switching areas) a special filtered version of the LHD is available. Indicators Fire Alarm Fault Alarm Operating Temperature Range Panel mounted continuous Red LED. Terminals for connection of remote LED. Panel mounted flashing Yellow LED. Fault output may be wired in series for normal 2 wire operation or connected separately (see note 2). -25 C to +55 C Controls Test Switch Calibration setting Notes Type Approval Hazardous Areas Eurocard Version Supply Voltage Current Consumption Quiescent Fire Alarm Fault Alarm Noise Performance Fault and Fire positions verify operation in both modes 12 position pre-calibrated pin switch (internally mounted) 1. In the FIRE condition the minimum voltage across the detector should be not less than 5V 2. When the fault output is used separately it must be referred to the 0V supply line The Alarmline LHD unit is approved for use by UK Power Generation companies under their reference 5117-P-11* * Electrical Environment Class-X (Mild) Alarmline high resistance sensor cable may be installed within hazardous environments as it is regarded by BASEEFA as a simple electrical apparatus. Approved Zener Barrier Configurations for use with the sensor electronic interface units (installed within a classified safe area) allows installation within Group IIC and less arduous environments. Nominal 24V d.c. Limits 20 to 30V d.c. With FAULT relay normally energised: 20mA With FAULT relay normally de-energised: 100 to 200µA depending on alarm trip setting With FAULT relay normally energised: 60mA With FAULT relay normally de-energised: 40mA With FAULT relay normally energised: 100 to 200µA depending on alarm trip setting With FAULT relay normally de-energised: 20mA Will withstand 1V rms 50Hz supply voltage and 1V rms 50Hz sensor noise with negligible performance change.

6 LHD4 Ordering Data K82012 Alarmline Series 4 LHD K82013 Alarmline Series 4 LHD (pcb only) Alarmline Series 4 LHD with relays K82194 Fault de-energised K82194-02 Fault energised K82033 Alarmline Series 4 Eurocard K82098 Alarmline Analogue portable demonstration kit Kidde Fire Protection operates a continuous programme of product development. The right is therefore reserved to modify any specification without prior notice and Kidde Fire Protection should be contacted to ensure that the current issues of all technical data sheets are used. Kidde Fire Protection 6245/1 04/04 Kidde Fire Protection Thame Park Road, Thame, Oxfordshire OX9 3RT Tel: +44 (0)1844 265003. Fax: +44 (0)1844 265156. E-mail: info@kfp.co.uk Web: www.kfp.co.uk