Unitized Energy Recovery Ventilators for use with Carrier Air Conditioning

Similar documents
INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

BUILD ING DE SIGN FOR COM MER CIAL BUILD INGS

Compak Unit Coolers. LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost. Bulletin LC-03A August 2004 (Replaces LC-03 3/03)

Submittal Data Performance Data Electrical Data

IN STAL LA TION IN STRUC TION

Bill McCullough. Director ERV Products. Dallas, TX

ENERGY RECOVERY VENTILATOR WITH OPTIONAL TEMPERING

INSTALLATION IN STRUC TION

VTC / VTH PRODUCT SPECIFICATIONS. ¾ Ton through 2 Tons VERTICAL TERMINAL AIR CONDITIONER AND HEAT PUMP

THERMAL MANAGEMENT OF MOBILE DEVICES

SOLVING PARAFFIN DEPOSITION PROBLEM IN TUBING BY HEATING CABLE APPLICATION

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

IN STAL LA TION IN STRUC TION

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

INSTALLATION, OPERATION & MAINTENANCE IN STRUC TIONS OIL-FIRED WATER HEATERS 72E 361E 541E

FIRE PROTECTION SYSTEMS

AHRI Guideline W (I-P) 2014 Guideline for Selecting, Sizing, & Specifying Packaged Air-to-Air Energy Recovery Ventilation Equipment

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

EXPERIMENTAL ANALYSIS OF PARALLEL PLATE AND CROSSCUT PIN FIN HEAT SINKS FOR ELECTRONIC COOLING APPLICATIONS

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

OIL-FIRED WATER HEATERS 72E 361E 541E

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

48PGD/E/F/L/M/N PG20-28

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB

INSTALLATION IN STRUC TIONS RECOMMENDED MODELS

Product Release Summary

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

AN EXPERIMENTAL ANALYSIS OF THE EFFECT OF REFRIGERANT CHARGE LEVEL AND OUTDOOR CONDITION ON A WINDOW AIR CONDITIONER

50TM TFF COMBINATION HEATING/COOLING UNITS

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

MiniCore Ventilator (500, 1000) Series Engineering Guide

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Wall Mounted Air Conditioners with Gas Heat Models AVGA

RT-OA TM Rooftop Outdoor-Air (DOAS)

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 60 HZ MODELS: EF-10 & FF-10

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

50TM COMBINATION HEATING/COOLING UNITS

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

Installation Instructions

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Advance Release September 2009

SOYA STRAW BALES COMBUSTION IN HIGH-EFFICIENT BOILER

INSTALLATION INSTRUCTIONS ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

6-10 Ton Pack age Unit Low Leak Mod u lat ing Economizer w/ W7220A JADE Con trol In stal la tion In struc tions

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

SUBMERSIBLE PUMP WITH HAZARDOUS LOCATION MOTOR END

ADSORBING FILTERS, DRYERS, CLEAN AIR PACKAGES

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

RGE 13 A T - 1 A

Modular Multi-position Air Handler

MODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS

Energy Recovery with Cooling and Heating

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

48TF GAS HEATING/ ELECTRIC COOLING UNITS

G21/GSR21 SERIES UNITS LENNOXOEMPARTS.COM

Visit us at For the latest technical information,

TECHNICAL SPECIFICATIONS

INSTALLATION INSTRUCTIONS MODELS (-)XRD-01RGHAM3 HORIZONTAL AIRFLOW ECONOMIZERS

Total Recovery for ALL Climates Models TR & TRC

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

220V SL & SLX Scissor Lift Video Projector Lift by Draper

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

TECHNICAL SPECIFICATIONS

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

Manual. Danfoil production A/S. Sjæl lands vej 8 DK Løg stør Tlf Fax

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

TECHNICAL SPECIFICATIONS

Product Specifications. Vertical Floor Consoles By First Co.

High Heat COP. High/Low Stage

CARBON DIOXIDE AS THE REPLACEMENT FOR SYNTHETIC REFRIGERANTS IN MOBILE AIR CONDITIONING. Dragi Lj. ANTONIJEVI]

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Energy Recovery with Cooling and Heating Model ERCH

48TM GAS HEATING/ELECTRIC COOLING UNITS

ANALYSIS OF SUSTAINABLE HVAC SYSTEM IN TOURISM FACILITIES ON THE ADRIATIC COAST

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

DCG Commercial. Submittal Data Form

Heat Recovery Units. Heat Recovery 1

Oct. 11, M. E. PENNINGTON 1,882,030 CONDITIONING SYSTEM FOR COLD STORAGE ROOMS

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

Transcription:

Engineering Data Unitized Energy Recovery Ventilators for use with Carrier Air Conditioning Energy recovery COMPONENT certified to the AHRI Air-to-Air Energy Recovery Ventilation Equipment Certification Program in accordance with AHRI Standard 1060-2000. Actual performance in packaged equipment may vary. Typical Applications March 31, 2009 Supercedes: 03-09-05 Re duces cool ing load at de sign tem per a tures up to 4 tons per 1000 cfm of out side air. Re duces heat ing load up to 12,000 Btuh per 400 cfm of out side air. Dry en ergy trans fer. Mois ture in sup ply (in take) air stream is trans ferred to ex haust air stream in a va por state, elim i nat ing con den sate plumb ing in the ventilator. At ta ches di rectly to the roof top units, upflow air han dlers or hor i zon tal air han dlers. All mount ing equip ment is pro vided. Sep a rate fused power sup ply. Fil ters / mist eliminators are pro vided on the en ter ing air open ings of the out door units. Ad just able sup port legs are pro vided on roof top mod els. Two modes of op er a tion (Piv ot ing Wheel Roof top Mod els). Recovery mode during normal energy recovery operation. True Economizer mode when outside sensor calls for economizer operation (packaged units equipped with economizers). U S Patent # 5,548,970. Piv ot ing wheel mod els used with pack aged unit with Roof top Sys tems economizer. Se quence of op er a tion con trolled by economizer. Bal anc ing damp ers pro vided on R Model Sta tion ary Wheel Mod ules. Cen trif u gal blow ers (both in take and ex haust) for high static ca pa bil ity and low sound lev els. Heavy gauge gal va nized steel cab i nets cor ro sion pro tected with pow der paint pro cess. Fully insulated cabinet. ARI rated in ter nal enthalpy wheel is pro vided. In ter nal enthalpy wheel made of poly meric ma te rial with sil ica gel im preg nated into the ma te rial. The enthalpy wheel has a five year lim ited war ran ty. Continuous operation down to 10oF (-12oC) without defrost at indoor relative humidity up to 40%. For temperatures below 10oF (-12oC), Optional Low Ambient Control Kit is required. Kit includes temperature sensor to shutoff power to UERV before frost build up can occur on recovery wheel. Staged power exhaust (larger models). ETL Certified per UL 1995 and CSA 22.2 UERV Unit with a 2-5 Ton Pack age Unit UERV Unit with Hor i zon tal Air Han dler (Re turn Air to Bot tom of UERV, Out side Air and Ex haust Duct ed to Out side) UERV Unit with Upflow Air Han dler (Re turn Air Duct ed, Out side Air and Ex haust Duct ed to Out side)

Ap pli ca tions Unitized Energy Recovery Ventilators (UERV) are used with the rooftop packaged units, upflow air handlers, and horizontal air handlers. The recovery wheel provides sensible and latent energy exchange between the entering and exhaust air streams of a building. This allows a substantial amount of the energy which is normally lost in the exhaust air stream to be returned into the entering air. Ideal applications are areas that have cold or hot temperatures with high occupancy loads or high ventilation requirements. Areas that have high humidity or very low humidity (recover exhaust humidity air from buildings that have humidifiers) are good applications. UERV s also reduce the design loads due to outside air, which can mean downsizing the air conditioning equipment. Application software is available to calculate the load reductions and provide the energy and dollar savings for all areas of the United States and Canada. Principle of Operation The UERV enthalpy wheel contains parallel layers of a polymeric material that are impregnated with silica gel (desiccant). The wheel is located in the entering (intake) air and exhaust air streams of the ventilation equipment. As the wheel rotates through each air stream, the wheel surface captures sensible and latent energy. In the heating mode, the wheel rotates to provide a constant transfer of heat from the exhaust air stream to the colder intake air stream. During the cooling season, the process is reversed. On rooftop units equipped with an economizer, the wheel pivots out of the air stream to allow economizer to operate normally for free cooling when outdoor temperature and humidity is acceptable. During economizer operation, the UERV exhaust blower continues to run, providing power exhaust for the system. The intake blower is de-energized during economizer operation. True Economizer Operation The UERV provides true economizer operation. By pivoting the wheel of the UERV out of the air stream, the air conditioning system can utilize 100% of the air conditioning units blower capabilities (U S Patent # 5,548,970). Most manufacturers have an economizer mode operation on their UERV systems. The competitors economizer mode simply stops or jogs the wheel so that it does not recover any energy. By stopping or jogging the wheel, they can only introduce fresh air up to the rated airflow of the UERV (normally less than 50%). They must also have both intake and exhaust blowers energized. Not all packaged units can have the pivoting wheel design due to air conditioning unit arrangement. Outside Air Blower (Energized) Enthalpy Wheel (Pivoted out of Intake and Discharge Air Stream) Fresh Air Damper (Opens during economizer operation) Exhaust Air Blower (Energized) Enthalpy Wheel (With removable pie segments) Exhaust Air Blower Unit & UERV Disconnect (Provided correct wire size used for both units and local code approval)

Enthalpy Wheels and ARI Energy Recovery Wheel The heart of the Unitary Energy Recovery Ventilator is the Energy Recovery Wheel (defined by ARI as a rotary heat exchanger). The wheel has a patented design of parallel layers of wrapped polymeric material that is impregnated with a silica gel (desiccant). This unique design makes it the only truly cleanable wheel on the market today. The small wheels (19 inch diameter) are slide out cassettes, and the larger wheels have pie segments that are removable for cleaning. ARI Stan dard 1060-2000 for Air-to-Air En ergy Re cov ery Ven ti la tion Equip ment The Air-Conditioning and Refrigeration Institute (ARI) issued Standard 1060-2000 to certify air-to-air energy recovery ventilators. This standard deals specifically with the ratings of the Energy Recovery Wheel that is incorporated into the Unitary Energy Recovery Ventilator (UERV). All of the RSI UERV s have an ARI certified energy recovery wheel. The data shown in the specification charts are the ARI certified data for the wheel. Actual performance in the UERV may vary. Wheel "1" "2" "3" Balancing Damper UERV Crit i cal Terms for Stan dard 1060 are as fol lows: 1. Effectiveness. The measured energy recovery effectiveness not adjusted to account for that portion of the psychometric change in the leaving supply air (Station 2) that is the result of leakage of entering exhaust air (Station 3) rather than exchange of heat or moisture between the air streams. 2. Net Effectiveness. The measured recovery effectiveness adjusted to account for that portion of the psychometric change in the leaving supply air (Station 2) that is the result of leakage of the entering exhaust air (Station 3) rather than exchange of heat or moisture between the air streams. 3. Exhaust Air Transfer Ratio (EATR). The tracer gas concentration difference between the leaving supply air (Station 2) and entering supply (outdoor) air stream (Station 1) divided by the tracer gas concentration in the entering exhaust (return) air (Station 3) at the 100% rated air-flow, expressed as a percentage. 4. Outdoor Air Correction Factor (OACF). The entering supply (outdoor) airflow (Station 1) divided by the measured (gross) leaving supply airflow (Station 2).

Optional Accessories UERV Equipment Support 8 inch (203 mm) high base for support of the exhaust and intake end of the UERV. UERV -CFM Part No. - 550 01-210-3608-1,000 01-210-4808-1,700 01-210-4808-2,800 01-210-4808-3,600 01-210-6008-4,600 01-210-6008-5,400 01-210-7608-5,800 01-210-7608 Roof Mounting Frame A 14 or 24 inch (356 or 610 mm) roof curb is required to match supply and exhaust openings of the UERV with the rooftop units. RSI provides a full line of roof curbs to match the specified unit. Low Ambient Control Kit Prevents frost formation on energy wheel heat transfer surfaces by terminating the intake blower operation when discharge air temperature falls below a field selectable temperature setting.. Intake blower operation resumes operation after temperature rises above the adjustable temperature differential. Pressure Sensor Measurement device on the UERV to determine airflow across the Enthalpy Wheel. Motorized Intake Air Damper Damper mounts in the outdoor air intake hood. It opens when the UERV is energized and closes when de-energized. Stop-Start-Jog Function that rotates the Enthalpy Wheel (non-pivoting models) on a preset timer to prevent contamination of the wheel during economizer operation. UERV Option Codes (ex.: 30-R28-46xH-33-L3 would be an R28 series high speed 460 volt 3 phase UERV with a Low Ambient Kit, Motorized Outside Air, and Stop-Start-Jog kit.) L1 L2 L3 L4 L5 L6 L7 L8 M1 M2 M3 M4 S1 S2 P1 Low Ambient Kit (LAK) LAK & Motorized. Outside Air (MOA) LAK, MOA, & Stop-Start-Jog (SSJ) LAK, MOA, SSJ, & Pressure Sensor (PS) LAK and SSJ LAK, SSJ, and PS LAK and PS LAK, MOA, and PS Motorized Outside Air (MOA) MOA and Stop-Start-Jog (SSJ) MOA, SSJ, and Pressure Sensor (PS) MOA and PS Stop-Start-Jog (SSJ) SSJ and Pressure Sensor (PS) Pressure Sensor (PS) How to Se lect the proper Air Con di tion ing Unit and Uni tary En ergy Re cov ery Ven ti la tor 1. Determine the air conditioning load requirements with the required amount of outside air without an UERV. 2. Select the proper UERV for the outside air requirements and calculate the tonnage reduction through the Airxchange software program. 3. Select the air conditioning unit required by reducing the load determined in step 1 by the reduction in step 2. (Example: If the load in Step 1 was 10 tons, and the reduction in Step 2 was 2.5 tons, select a 7.5 ton unit.) 4. Select the proper UERV based on the select unit. The RSI part numbering scheme is as follows: 30-R28-46xH-33-L2 Option Code (see list above) Voltage - Phase Blower Speed (H for high, M for Medium) Carrier Unit Cabinet Size UERV Series (Enthalpy Wheel designation) Carrier Designation -40 48 GS/JZ 024-036 / 48 SD 018-036 50 GL/JZ/XP/XZ 024-036 / 50 SZ 024-030 -41 48 SD 042-060 / 48 GP/JZ 042-060 50 SZ 036-060 / 50 GL/JE/XP/XZ 042-060 -44 48 TM/TF/TFF/HJ/TFQ/HJQ 004-007 50 TM/TF/TFF/HJ/TFQ/HJQ 004-007 -45 48/50 TM/TF/TFF 008-009/ HJ 008 50 TFQ/HJQ 008-46 48/50 TM/TF/TFF 012-014 / HJ 009 50 TFQ/HJQ 012-10 48/50 TM 016, 020, 025, 028 / TJ 016-028 48/50 HJ 015, 017 / 50 HJQ 014, 016

UERV Out side Air CFM Se lec tion Ta ble by CFM Unit - Tons 300-550 600-1000 1100-1700 1500-2800 2800-3600 3400-4600 4800-5400 5400-6200 2-5 2-5 Stand Alone type UERV s are available for all tonnage sizes. Rooftop 7.5-12.5 7.5 12.5 7.5 12.5 7.5 12.5 7.5 12.5 15-30 15 30 15 30 15 30 15 30 Upflow 2-5 2-5 Horizontal 2-5 2-5 Stand Alone UERV s are available for equipment room applications. Cross Leak age in UERV s (Purge Sec tors) The issue of cross leakage in rotary wheel based UERV s used in space conditioning applications is often misunderstood. As a result, many systems are installed with purge sectors and the additional fan capacity required to allow these sectors to function when in fact they are unnecessary. A better understanding of the rational for the purge sector, and its history, allows us to dispense with the purge sector, its added first cost and continuing cost of operation. A purge sector minimizes the carry over cross leakage from the exhaust into the supply (outside air ) air stream by shunting a portion of the supply air back into the exhaust air stream across the seal separating the exhaust and supply. This is required in industrial applications where the exhaust carries contaminants. This typically results in air volume being 15% to 20% higher to get the desired air intake, and the cost associated with it. In space conditioning applications, where the ventilation is operating to maintain acceptable indoor air quality, there are no contaminants in concentrations of concern. Cross leakage in the UERV system results in a small amount of the exhaust air, typically less than 5% in balanced airflow, returning to the space. This is not contaminated air, as some would suggest. It is however air that effectively never left the space. The operation cost of moving this air is far less that that required for a purge sector. Do not use the RSI UERV s in applications that have concentrations of contaminants.

Per for mance - 1 ½ through 8 ton units Use this table to determine ventilation and size requirements. Table shows Carrier packaged units and matching UERV model, Air Flow Range, and ARI rated Net Effectiveness at 100% of rated CFM. Car rier Pack aged Unit Model No. 48 GS/JZ 024-036 48 SD 018-036 50 GL/JZ/XP/XZ 024-036 50 SZ 024-030 48 SD 042-060 48 GP/JZ 042-060 50 SZ 036-060 50 GL/JE/XP/XZ 042-060 48 TM/HJ/HJQ 004-007 48 TF/TFF/TFQ 004-007 50 TM/HJ/HJQ 004-007 50 TF/TFF/TFQ 004-007 48/50 TM/TF/TFF 008-009 48/50 HJ 008 50 TFQ/HJQ 008 R Series Stationary Wheel for Units without Economizers Unit Size (Tons) UERV CFM Range RSI UERV Model No. 1.5-3.5 300-550 30-R06-40xH 3.5-5 300-550 30-R06-41xH 3.5-5 7.5 300-550 30-R06-44xH 600-1000 30-R11-44xH 600-1000 30-R11-45xH 1100-1700 30-R20-45xH 1500-2200 30-R28-45xM 2200-2800 30-R28-45xH Elect. Volt age - Phase -01 110v - 1ph -21 208/230v - 1ph -01 110v - 1ph -21 208/230v - 1ph -01 110v - 1ph -21 208/230v - 1ph -43 575v-3ph Nom i nal ARI Data (To tal) Net Ef fec tive ness CFM Heat ing Cooling 500 65% 64% 500 65% 64% 500 65% 64% 900 73% 72% 900 73% 72% 1600 65% 64% 1950 71% 70% 2600 65% 63% Note: 1. Com plete RSI UERV model num ber in cludes the elec tri cal in for ma tion. Ex am ple: 48 TF 007 need ing 500 CFM out side of air at 230 volts - 3 phase. Model would be a 30-R06-44xH-23.

Per for mance 10 through 25 ton units Use this table to determine ventilation and size requirements. Table shows Carrier packaged units and matching UERV model, Air Flow Range, and ARI rated Net Effectiveness at 100% of rated CFM. Car rier Pack aged Unit Model No. 48/50 TM/TF/TFF 012-014 48/50 HJ 009 50 TFQ/HJQ 012 48 TM 016,020,025,028 50 TM 016,020,025,028 48/50 TJ 016-028 48/50 HJ 015, 017 50 HJQ 014, 016 R Series Stationary Wheel for Units without Economizers Unit Size (Tons) 10-12.5 12.5-20 UERV CFM Range RSI UERV Model No. 1100-1700 30-R20-46xH 1500-2200 30-R28-46xM 2200-2800 30-R28-46xH 1500-2200 30-R28-10xM 2200-2800 30-R28-10xH 2800-3600 30-R36-10xH 3400-4600 30-R46-10xH 5500-6200 30-R62-10xH Elect. Volt age - Phase Nom i nal ARI Data (To tal) Net Ef fec tive ness CFM Heat ing Cooling 1600 65% 64% 1950 71% 70% 2600 65% 63% 1950 71% 70% 2600 65% 63% 3100 65% 63% 3900 65% 63% 5500 65% 63% Note: 1. Com plete RSI UERV model num ber in cludes the elec tri cal in for ma tion. Ex am ple: 48 TF 012 need ing 1200 CFM out side of air at 230 volts - 3 phase. Model would be a 30-R20-46xH-23.

Per for mance - 1 ½ through 8 ton units Use this table to determine ventilation and size requirements. Table shows Carrier packaged units and matching UERV model, Air Flow Range, and ARI rated Net Effectiveness at 100% of rated CFM. Car rier Pack aged Unit Model No. 48 TM/HJ/HJQ 004-007 48 TF/TFF/TFQ 004-007 50 TM/HJ/HJQ 004-007 50 TF/TFF/TFQ 004-007 48 TM/TF/TFF 008-009 50 TM/TF/TFF 008-009 48/50 HJ 008 50 TFQ/HJQ 008 Unit Size (Tons) P Se ries Piv ot ing Wheel for Units with Econ o miz ers UERV CFM Range Power Ex haust RSI UERV Model No. 3.5-5 600-1000 1900 30-P11-44xH 7.5 600-1000 1900 30-P11-45xH 1100-1700 3000 30-P20-45xH 1500-2200 3450 30-P28-45xM 2200-2800 4200 30-P28-45xH Elect. Volt age - Phase Nom i nal ARI Data (To tal) Net Ef fec tive ness CFM Heat ing Cooling 900 73% 72% 900 73% 72% 1600 65% 64% 1950 71% 70% 2600 65% 63% Note: 1. Com plete RSI UERV model num ber in cludes the elec tri cal in for ma tion. Ex am ple: 48 TF 007 need ing 800 CFM out side of air at 230 volts - 3 phase. Model would be a 30-P11-44xH-23.

Per for mance 10 through 25 ton units Use this table to determine ventilation and size requirements. Table shows Carrier packaged units and matching UERV model, Air Flow Range, and ARI rated Net Effectiveness at 100% of rated CFM. Car rier Pack aged Unit Model No. 48 TM/TF/TFF 012-014 50 TM/TF/TFF 012-014 48/50 HJ 009 50 TFQ/HJQ 012 48 TM 016,020,025,028 50 TM 016,020,025,028 48/50 TJ 016-028 48/50 HJ 015, 017 50 HJQ 014, 016 Unit Size (Tons) 10-12.5 12.5-20 P Se ries Piv ot ing Wheel for Units with Econ o miz ers UERV CFM Range Power Exhaust RSI UERV Model No. 1100-1700 3000 30-P20-46xH 1500-2200 3450 30-P28-46xM 2200-2800 4200 30-P28-46xH 1500-2200 3450 30-P28-10xM 2200-2800 4200 30-P28-10xH 2800-3600 4650 30-P36-10xH 3400-4600 5600 30-P46-10xH 5500-6200 13000 30-P62-10xH Elect. Volt age - Phase Nom i nal ARI Data (To tal) Net Ef fec tive ness CFM Heat ing Cooling 1600 65% 64% 1950 71% 70% 2600 65% 63% 1950 71% 70% 2600 65% 63% 3100 65% 63% 3900 65% 63% 5500 65% 63% Note: 1. Com plete RSI UERV model num ber in cludes the elec tri cal in for ma tion. Ex am ple: 48 TF 012 need ing 1200 CFM out side of air at 230 volts - 3 phase. Model would be a 30-P20-46xH-23.

Spec i fi ca tions and Elec tri cal Data - 300 through 550 CFM UERV's R06 - Roof top Sta tion ary UERV Series H06 - Hor i zon tal Split Sys tem U06 - Upflow Split Sys tem Line Volt age - 60hz 115v - 1ph 208*/230*/460*v - 1ph 208*/230*/460*v - 3ph Mo tor - hp 0.2 / PSC Fresh Air Blower Ex haust Air Blower Wheel Elec tri cal Data To tal Elec tri cal Wheel Size (dia x width) -in 5.5 x 6.3 Mo tor Speed -rpm 1780 Mo tor Speed(s) 2 Sleeve Full Load Amps 3.8 Serv ice Fac tor 1.1 Mo tor - hp 0.25 / PSC Wheel Size (dia x width) -in 5.5 x 6.3 Mo tor Speed -rpm 1780 Mo tor Speed(s) 2 Sleeve Full Load Amps 3.8 Serv ice Fac tor 1.1 Po ten tial Volts 115 Mo tor Speed -rpm 1050 Full Load Amps 0.6 MCA 8.7 OCPD 10.0 Wheel Depth 2 Wheel Data Wheel Di ame ter -in 19.3 Con struc tion One Piece / Poly meric Curb A/C Unit Curb Height - in 14 Weights Ship ping Weight - lbs. (kg) 198 Net Weight - lbs. (kg) 155 *Note: A stepdown trans former is pro vided to stepdown high volt age pri mary to 115 volt sec ond ary. ARI Cer ti fied Rat ings Ther mal Rat ings @ 0" Pres sure Diff. Sensible Latent Total 100% Air flow Heat ing 68% 60% 65% To tal Ef fec tive ness 75% Air flow Heat ing 73% 65% 70% 100% Air flow Cool ing 68% 60% 64% 75% Air flow Cool ing 73% 65% 69% 100% Air flow Heat ing 68% 60% 65% Net Ef fec tive ness 75% Air flow Heat ing 73% 65% 70% 100% Air flow Cool ing 68% 60% 64% 75% Air flow Cool ing 73% 65% 69% Enthalpy Wheel Air flow Data Nom i nal Air flow CFM 500 @.6 EATR - -0.50 H2O 9.90% EATR - 0.00 H2O 0.20% EATR - +0.50 H2O 0.00% OACF - -0.50 H2O 1.02 OACF - 0.00 H2O 1.33 OACF - +0.50 H2O 1.59

Spec i fi ca tions and Elec tri cal Data - 600 through 1000 CFM UERV's R11 - Roof top Sta tion ary UERV Series P11 - Roof top Piv ot ing H11 - Horizontal U11 - Upflow Line Volt age - 60hz 208/230v - 1ph 208/230v - 3ph 460v - 1ph 460/*575v - 3ph Mo tor - hp 0.5 / PSC Wheel Size (dia x width) -in 10 x 6 AT Fresh Air Blower Ex haust Air Blower Wheel Elec tri cal Data To tal Elec tri cal Mo tor Speed -rpm 1120 / 960 / 850 Mo tor Speed(s) 3 Sleeve Full Load Amps 3.4 Serv ice Fac tor 1.0 Mo tor - hp Sta tion ary 0.5 / PSC Mo tor - hp Piv ot ing 0.5 / PSC Wheel Size (dia x width) -in 10 x 6 AT Mo tor Speed -rpm 1120 / 960 / 850 Mo tor Speed(s) 3 Sleeve Full Load Amps- Stationary 3.4 1.5 Full Load Amps- Pivoting 3.4 1.5 Serv ice Fac tor 1.0 Po ten tial Volts 208 / 230 Mo tor Speed -rpm 1050 Full Load Amps 0.6 MCA - Sta tion ary 8.25 4.4 OCPD - Sta tion ary 10.0 6.0 MCA - Piv ot ing 8.25 4.4 OCPD - Piv ot ing 10.0 6.0 Wheel Depth - in 3 Wheel Data Wheel Di ame ter - in 25.3 Con struc tion / Me dia One Piece / Poly meric Curb A/C Unit Curb Hgt - in 14 or 24 Weights Ship ping Weight - lbs. (kg) 318 Net Weight - lbs. (kg) 245 * Note: A stepdown trans former is pro vided to stepdown 575v pri mary to 460v sec ond ary. ARI Cer ti fied Rat ings Ther mal Rat ings @ 0" Pres sure Diff. Sensible Latent Total 100% Air flow Heat ing 76% 68% 73% To tal Effectiveness 75% Air flow Heat ing 81% 73% 78% 100% Air flow Cool ing 76% 68% 72% 75% Air flow Cool ing 81% 73% 76% 100% Air flow Heat ing 76% 68% 73% Net Effective ness 75% Air flow Heat ing 81% 73% 78% 100% Air flow Cool ing 76% 68% 72% 75% Air flow Cool ing 81% 73% 76% Enthalpy Wheel Air flow Data Nom i nal Air flow CFM 900 @ 1.0 EATR - -1.00 H2O 9.30% EATR - 0.00 H2O 0.70% EATR - +1.00 H2O 0.00% OACF - -1.00 H2O 0.97 OACF - 0.00 H2O 1.19 OACF - +1.00 H2O 1.34

Spec i fi ca tions and Elec tri cal Data - 1100 through 1700 CFM UERV's R20 - Roof top Sta tion ary UERV Series P20 - Roof top Piv ot ing Line Volt age - 60hz 208/230v - 3ph 460v - 3ph 575v - 3ph Mo tor - hp 1 / Belt Fresh Air Blower Ex haust Air Blower Wheel Elec tri cal Data To tal Elec tri cal Wheel Size (dia x width) -in 9 x 9 Mo tor Speed -rpm 1725 Mo tor Speed(s) Adjustable Sheave Ball Full Load Amps 3.8 1.9 1.4 Ser vice Fac tor 1.15 Mo tor - hp Sta tion ary 1 / Belt Mo tor - hp Piv ot ing 1.5 / Belt Wheel Size (dia x width) -in 9 x 9 Mo tor Speed -rpm 1725 Mo tor Speed(s) Adjustable Sheave Ball Full Load Amps-Sta tion ary 3.8 1.9 1.4 Full Load Amps-Piv ot ing 5.6 2.8 2.0 Ser vice Fac tor 1.15 Po ten tial Volts 208 / 230 Mo tor Speed -rpm 1050 Full Load Amps 0.6 MCA - Sta tion ary 9.15 4.9 3.8 OCPD - Sta tion ary 12.0 6.0 5.0 MCA - Piv ot ing 11.4 6.0 4.5 OCPD - Piv ot ing 15.0 8.0 6.0 Wheel Depth - in 3 Wheel Data Wheel Di am e ter - in 30.346 Con struc tion / Me dia One Piece / Poly meric Curb A/C Unit Curb Hgt - in 14 or 24 Weights Ship ping Weight - lbs. (kg) 425 Net Weight - lbs. (kg) 345 ARI Cer ti fied Ratings Ther mal Rat ings @ 0" Pres sure Diff. Sensible Latent Total 100% Air flow Heat ing 68% 61% 65% To tal Effective ness 75% Air flow Heat ing 72% 67% 71% 100% Air flow Cool ing 68% 61% 64% 75% Air flow Cool ing 72% 67% 70% 100% Air flow Heat ing 68% 61% 65% Net Effective ness 75% Air flow Heat ing 72% 67% 71% 100% Air flow Cool ing 68% 61% 64% 75% Air flow Cool ing 72% 67% 70% Enthalpy Wheel Airflow Data Nom i nal Air flow CFM 1600 @.95 EATR - -1.00 H2O 7.80% EATR - 0.00 H2O 0.40% EATR - +1.00 H2O 0.00% OACF - -1.00 H2O 0.97 OACF - 0.00 H2O 1.16 OACF - +1.00 H2O 1.29

Spec i fi ca tions and Elec tri cal Data - 1500 through 2800 CFM UERV's R28 - Roof top Sta tion ary UERV Series P28 - Roof top Piv ot ing Line Volt age - 60hz 208/230v 3ph 460v 3ph 575v 3ph Mo tor - hp / type 1.5 / Belt Fresh Air Blower Ex haust Air Blower Wheel Elec tri cal Data To tal Elec tri cal Wheel Size (dia x width) -in 10 x 10 Mo tor Speed -rpm 1725 Mo tor Speed(s) Adjustable Sheave Ball Full Load Amps 5.6 2.8 2.0 Serv ice Fac tor 1.15 Mo tor - hp Sta tion ary 1.5 / Belt Mo tor - hp Piv ot ing 3 / Belt Wheel Size (dia x width) -in 10 x 10 Mo tor Speed -rpm 1725 Mo tor Speed(s) Adjustable Sheave Ball Full Load Amps- Stationary 5.6 2.8 2.0 Full Load Amps- Pivoting 9.0 4.4 3.6 Serv ice Fac tor 1.15 Mo tor - hp (1 phase) 0.17 Po ten tial Volts 200-208 / 230 Mo tor Speed -rpm 1725 Full Load Amps 1.1 MCA - Sta tion ary 13.7 7.4 5.6 OCPD - Sta tion ary 20.0 10.0 7.0 MCA - Piv ot ing 18.0 9.4 7.6 OCPD - Piv ot ing 25.0 12.0 10.0 Wheel Depth x Di ame ter - in 3 x 37.759 Wheel Data Con struc tion / Me dia Type Seg mented Pies/Poly meric Curb A/C Unit Curb Height - in 14 or 24 Ship ping Weight - lbs. (kg) 470 Weights Net Weight - lbs. (kg) 395 ARI Cer ti fied Rat ings Ther mal Rat ings @ 0" Pres sure Diff. Sensible Latent Total 100% Air flow Heat ing 68% 60% 65% To tal Effective ness 75% Air flow Heat ing 74% 67% 71% 100% Air flow Cool ing 68% 60% 63% 75% Air flow Cool ing 74% 67% 70% 100% Air flow Heat ing 68% 60% 65% Net Effective ness 75% Air flow Heat ing 74% 67% 71% 100% Air flow Cool ing 68% 60% 63% 75% Air flow Cool ing 74% 67% 70% Enthalpy Wheel Air flow Data Nom i nal Air flow CFM 2600 @.95 EATR - -1.00 H2O 6.10% EATR - 0.00 H2O 0.40% EATR - +1.00 H2O 0.00% OACF - -1.00 H2O 0.99 OACF - 0.00 H2O 1.13 OACF - +1.00 H2O 1.23

Spec i fi ca tions and Elec tri cal Data - 2800 through 3600 CFM UERV's R36 - Roof top Sta tion ary UERV Series P36 - Roof top Piv ot ing Line Volt age - 60hz 208/230v 3ph 460v 3ph 575v 3ph Mo tor - hp / type 2 / Belt Fresh Air Blower Ex haust Air Blower Wheel Elec tri cal Data To tal Elec tri cal Wheel Size (dia x width) -in 12 x 9 Mo tor Speed -rpm 1725 Mo tor Speed(s) Adjustable Sheave Ball Full Load Amps 6.6 3.3 2.4 Serv ice Fac tor 1.15 Mo tor - hp Sta tion ary 2 / Belt Mo tor - hp Piv ot ing 3 / Belt Wheel Size (dia x width) -in 12 x 9 Mo tor Speed -rpm 1725 Mo tor Speed(s) Adjustable Sheave Ball Full Load Amps- Stationary 6.6 3.3 2.4 Full Load Amps- Pivoting 9.4 4.3 3.2 Serv ice Fac tor 1.15 Mo tor - hp (1 phase) 0.5 Po ten tial Volts 200-208 / 230 Mo tor Speed -rpm 1725 Full Load Amps 1.2 MCA - Sta tion ary 16.1 8.6 6.6 OCPD - Sta tion ary 20.0 12.0 9.0 MCA - Piv ot ing 19.6 9.9 7.6 OCPD - Piv ot ing 25.0 15.0 10.0 Wheel Depth x Di ame ter - in 3 x 41.825 Wheel Data Con struc tion / Me dia Type Seg mented Pies/Poly meric Curb A/C Unit Curb Height - in 14 or 24 Ship ping Weight - lbs. (kg) 571 Weights Net Weight - lbs. (kg) 475 ARI Cer ti fied Rat ings Ther mal Rat ings @ 0" Pres sure Diff. Sensible Latent Total 100% Air flow Heat ing 68% 60% 65% To tal Effective ness 75% Air flow Heat ing 74% 67% 71% 100% Air flow Cool ing 68% 60% 63% 75% Air flow Cool ing 74% 67% 70% 100% Air flow Heat ing 68% 60% 65% Net Ef fec tive ness 75% Air flow Heat ing 74% 67% 71% 100% Air flow Cool ing 68% 60% 63% 75% Air flow Cool ing 74% 67% 70% Enthalpy Wheel Air flow Data Nom i nal Air flow CFM 3100 @.9 EATR - -1.00 H2O 4.90% EATR - 0.00 H2O 1.30% EATR - +1.00 H2O 0.30% OACF - -1.00 H2O 0.99 OACF - 0.00 H2O 1.07 OACF - +1.00 H2O 1.12

Spec i fi ca tions and Elec tri cal Data - 3400 through 4600 CFM UERV's R46 - Roof top Sta tion ary UERV Series P46 - Roof top Piv ot ing Line Volt age - 60hz 208/230v 3ph 460v 3ph 575v 3ph Mo tor - hp / type 3 / Belt Fresh Air Blower Ex haust Air Blower Wheel Elec tri cal Data To tal Elec tri cal Wheel Size (dia x width) -in 12 x 12 Mo tor Speed -rpm 1725 Mo tor Speed(s) Adjustable Sheave Ball Full Load Amps 9.0 4.4 3.4 Serv ice Fac tor 1.15 Mo tor - hp Sta tion ary 3 / Belt Mo tor - hp Piv ot ing 5 / Belt Wheel Size (dia x width) -in 12 x 12 Mo tor Speed -rpm 1725 Mo tor Speed(s) Adjustable Sheave Ball Full Load Amps- Stationary 9.4 4.3 3.2 Full Load Amps- Pivoting 14.8 7.0 5.1 Serv ice Fac tor 1.15 Mo tor - hp (1 phase) 0.5 Po ten tial Volts 200-208 / 230 Mo tor Speed -rpm 1150 Full Load Amps 1.2 MCA - Sta tion ary 22.0 11.0 8.7 OCPD - Sta tion ary 30.0 15.0 12.0 MCA - Piv ot ing 28.7 14.4 11.0 OCPD - Piv ot ing 40.0 20 15.0 Wheel Depth x Di ame ter - in 3 x 46.776 Wheel Data Con struc tion / Me dia Type Seg mented Pies/Poly meric Curb A/C Unit Curb Height - in 14 or 24 Ship ping Weight - lbs. (kg) 920 Weights Net Weight - lbs. (kg) 805 ARI Cer ti fied Rat ings Ther mal Rat ings @ 0" Pres sure Diff. Sensible Latent Total 100% Air flow Heat ing 68% 60% 65% To tal Effective ness 75% Air flow Heat ing 73% 67% 71% 100% Air flow Cool ing 68% 60% 63% 75% Air flow Cool ing 73% 67% 70% 100% Air flow Heat ing 68% 60% 65% Net Effective ness 75% Air flow Heat ing 73% 67% 71% 100% Air flow Cool ing 68% 60% 63% 75% Air flow Cool ing 73% 67% 70% Enthalpy Wheel Air flow Data Nom i nal Air flow CFM 3900 @.95 EATR - -1.00 H2O 4.40% EATR - 0.00 H2O 1.10% EATR - +1.00 H2O 0.20% OACF - -1.00 H2O 0.99 OACF - 0.00 H2O 1.06 OACF - +1.00 H2O 1.11

Spec i fi ca tions and Elec tri cal Data - 4800 through 6200 CFM UERV's UERV Series R62 - Roof top Sta tion ary P62 - Roof top Piv ot ing Line Volt age - 60hz 208/230v 3ph 460v 3ph 575v 3ph Mo tor - hp / type 5 / Belt Wheel Size (dia x width) -in 12 x 12 Mo tor Speed -rpm 1725 Fresh Air Blower Mo tor Speed(s) Adjustable Sheave Ball Full Load Amps 15.0 7.4 5.8 Serv ice Fac tor 1.15 Mo tor - hp Sta tion ary 5 / Belt Mo tor - hp Piv ot ing (2) 5 / Belt Ex haust Air Blower Wheel Elec tri cal Data To tal Elec tri cal Wheel Size (dia x width) -in 12 x 12 Mo tor Speed -rpm 1725 Mo tor Speed(s) Adjustable Sheave Ball Full Load Amps- Stationary 14.8 7.0 5.1 Full Load Amps- Pivoting 14.8 7.0 5.1 Serv ice Fac tor 1.15 Mo tor - hp (1 phase) 0.5 Po ten tial Volts 200-208 / 230 Mo tor Speed -rpm 1075 Full Load Amps 1.2 MCA - Sta tion ary 34.8 17.5 13.6 OCPD - Sta tion ary 50.0 25.0 20.0 MCA - Piv ot ing 34.8 17.5 13.6 OCPD - Piv ot ing 50.0 25.0 20.0 Wheel Depth x Di ame ter - in 3 x 52.026 Wheel Data Con struc tion / Me dia Type Seg mented Pies/Poly meric Curb A/C Unit Curb Height - in 14 or 24 Ship ping Weight - lbs. (kg) 1250 Weights Net Weight - lbs. (kg) 1075 ARI Cer ti fied Rat ings Ther mal Rat ings @ 0" Pres sure Diff. Sensible Latent Total 100% Air flow Heat ing 68% 60% 65% To tal Effective ness 75% Air flow Heat ing 73% 67% 71% 100% Air flow Cool ing 68% 60% 63% 75% Air flow Cool ing 73% 67% 70% 100% Air flow Heat ing 68% 60% 65% Net Effective ness 75% Air flow Heat ing 73% 67% 71% 100% Air flow Cool ing 68% 60% 63% 75% Air flow Cool ing 73% 67% 70% Enthalpy Wheel Air flow Data Nom i nal Air flow CFM 5500 @.95 EATR - -1.00 H2O 4.00% EATR - 0.00 H2O 1.00% EATR - +1.00 H2O 0.20% OACF - -1.00 H2O 0.99 OACF - 0.00 H2O 1.06 OACF - +1.00 H2O 1.10

14" High Curbs Re quired on "R06" UERV Di men sional Data - 018-060 - inches (mm) C A D B Note: "D" is hood depth Exhaust Blower Equipment Support (Optional) 3 ½ 34 Outdoor Air Intake Blower Enthalpy Wheel UERV Model Cabinets Used With A B C D CFM 30-R06-40 48 GS/JZ 024-036 48 SD 018-036 50 GL/JZ/XP/XZ 024-036 24.75 (629) 24.63 (626) 34.56 (878) 8.00 (203) 300-550 50 SZ 024-030 30-R06-41 48 SD 042-060 48 GP/JZ 042-060 50 SZ 036-060 50 GL/JE/XP/XZ 042-060 24.75 (629) 24.63 (626) 34.56 (878) 8.00 (203) 300-550 14" High Curbs Re quired on "R06" 24" High Curbs Re quired on "R11" & "P11" C A D Enthalpy Wheel B Outdoor Air Intake Blower Note: "D" is hood depth UERV Model Cabinets Used With A B C D CFM 30-R06-44 24.75 (629) 24.63 (626) 34.56 (878) 8.00 (203) 300-550 48/50 TM/HJ/HJQ 004-007 30-R11-44 48/50 TF/TFF/TFQ 004-007 32.13 (816) 33.50 (851) 44.75 (1137) 11.00 (279) 600-1000 30-P11-44

14" High Curbs Re quired on "R11" & "P11" 24" High Curbs Re quired on "R20" & "P20" 24" High Curbs Re quired on "R28" & "P28" UERV Di men sional Data - 008-028 - inches (mm) A C D B En thalpy Wheel Outdoor Air Intake Blower Fil ter Ac cess is through hor i zon tal duct open ing UERV Model Cabinets Used With A B C D CFM 30-R11-45 30-P11-45 32.13 (816) 33.50 (851) 44.75 (1137) 11.00 (279) 600-1000 30-R20-45 48/50 TM/TF/TFF 008-009 30-P20-45 48/50 HJ 008 37.25 (946) 37.50 (953) 54.38 (1381) 20.32 (516) 1100-1700 50 TFQ/HJQ 008 30-R28-45 30-P28-45 42.63 (1083) 43.56 (1106) 52.25 (1327) 18.32 (465) 1500-2800 30-R11-46 30-P11-46 32.13 (816) 33.50 (851) 44.75 (1137) 11.00 (279) 600-1000 30-R20-46 48/50 TM/TF/TFF 012-014 30-P20-46 48/50 HJ 009 37.25 (946) 37.50 (953) 54.38 (1381) 20.32 (516) 1100-1700 50 TFQ/HJQ 012 30-R28-46 30-P28-46 42.63 (1083) 43.56 (1106) 52.25 (1327) 18.32 (465) 1500-2800 24" High Curbs Re quired on "R28" & "P28" 24" High Curbs Re quired on "R36" & "P36" 24" High Curbs Re quired on "R46" & "P46" 24" High Curbs Re quired on "R62" & "P62" Note: 62 Size Shown C A D B En thalpy Wheel Outdoor Air Intake Blower UERV Model Cabinets Used With A B C D CFM 30-R28-10 30-P28-10 42.63 (1083) 43.56 (1106) 52.25 (1327) 18.32 (465) 1500-2800 30-R36-10 48/50 TM 016,020,025,028 30-P36-10 48/50 TJ 016-028 46.68 (1186) 57.38 (1457) 60.00 (1524) 18.32 (465) 2800-3600 30-R46-10 48/50 HJ 015, 017 30-P46-10 50 HJQ 014, 016 52.68 (1338) 57.38 (1457) 60.00 (1524) 18.32 (465) 3400-4600 30-R62-10 30-P62-10 58.88 (1496) 57.38 (1457) 60.00 (1524) 18.32 (465) 4800-6200

Hor i zon tal Split Sys tem UERV s (inches) UERV Balancing Damper Air Handler H06 & U06 Trans former Kit Model No. Volt age - Phase 01-TRN-201 208v - 1ph 01-TRN-203 208v - 3ph 01-TRN-231 230v - 1ph 01-TRN-233 230v - 3ph 01-TRN-461 460v - 1ph 01-TRN-463 460v - 3ph Note: Trans former kits are field in stalled. UERV Intake Air (Field Selected) Air Handler End A B Control Box (Moveable to Either Side) C Exhaust Air (Transition Provided) E D Filter Rack (1 or 2 Inch) Dimensions Model No. H06 H11 CFM Range 300-550 600-1000 A 34.13 40.25 B 24.38 30.25 C 24.62 32.50 D 5.63 10.00 E 39.75 50.25 Intake Duct 9 rd 10 rd Exhaust Duct 9 rd 10 rd Return Duct (bot tom of UERV) 16 or 18 oval 16 or 18 oval Features 1. Fresh air intake can be field located on top or end of unit. 2. Electrical control box can be located to either side for access. 3. Access panels located on both sides of UERV for servicing. 4. Static test ports are provided for verification of CFM. 5. Filter rack accepts 1" or 2" filters and comes with flex connector to air handler. Note: Applications with extensive duct on intake and exhaust may require booster fans.

Upflow Split Sys tem UERV s (inches) 01U0601xD Se ries for 300-450 CFM UERV for Duct ed Ap pli ca tions Features include service access from either end with control box moveable to either side. Note: Applications with extensive duct on intake and exhaust may require booster fans. 01U0601xW Se ries for 300-450 CFM UERV for Thru-the-Wall Ap pli ca tions Features include service access from either end with control box moveable to either side. Air Handler Control Box Exhaust Air (9 Dia) Intake Air (9 Dia) Duct Box (D1-Option) Ex ploded view Per fect method of add ing UERV to ex ist ing school class room 29.125 15.625 29.125 24.5 22.5 24.5 37 18.125 Exhaust Air (9 Dia) 36.75 14 Return Duct (16 or 18 dia) Filter Rack Intake Air (9 Dia) Filter Rack 28 10 23.875 30.125 22.5 40.125 Wall Sleeve (W1-Op tion) U11 Se ries for 600-1000 CFM UERV for Duct ed Ap pli ca tions The U11 ducted series is designed for installations that require higher airflow. The air handler is installed on top of one end of the UERV. Return, intake, and exhaust air is ducted to the UERV. Note: Applications with extensive duct on intake and exhaust may require booster fans. Air Handler Outline 31.375 24.75 40.25 30.25 Return Air (16 or 18 Dia) Exhaust Air (10 Rd Dia) (Transition Provided) 32.50 Intake Air (10 rd dia on end of UERV) 65 Static Test Ports

Car rier Hor i zon tal and Upflow Split Sys tem UERV Mod els 300-550 CFM Car rier Model Air Han dler Size RSI Horizontal Model RSI Upflow Model Voltage 045-08 thru 070-12 30-U06-01xH-01 090-14 111-12 30-U06-02xH-01 090-16 58PAV 111-16 135-16 111-20 NA 30-U06-03xH-01 110 135-20 155-20 30-U06-04xH-01 018 024 30-H06-05xH-01 30-U06-05xH-01 F(A/B/C)4*N 030 110 30-H06-06xH-01 30-U06-06xH-01 036 038 thru 060 30-H06-07xH-01 30-U06-07xH-01 Note: To designate whether the upflow UERV is ducted or thru-the-wall add to end of RSI model# "D1" for ducted or "W1" for wall type. Example: A UERV for wall sleeve application for a 58PAV111-12 would be a 30-U06-02xH-01W1. Car rier Hor i zon tal and Upflow Split Sys tem UERV Mod els 600-1000 CFM Car rier Model Air Han dler Size RSI Horizontal Model RSI Upflow Model Voltage 58PAV F(A/B/C)4*N 045-08 thru 070-12 30-U11-01xH 090-14 111-12 30-U11-02xH 090-16 111-16 NA 30-U11-03xH 135-16 111-20 135-20 30-U11-04xH 155-20 018 024 30-H11-05xH 30-U11-05xH 030 036 30-H11-06xH 30-U11-06xH 038 thru 060 30-H11-07xH 30-U11-07xH Note: Voltages are either single or three phase on 600 to 1000 CFM UERV's 208-230 / 460 208-230 / 460

Notes

Notes

Prepared for the guidance of architects, consulting engineers, and mechanical contractors. Guide Spec i fi ca tions General Fur nish and in stall me chani cal cool ing sys tem, com plete with a Unit ized En ergy Re cov ery Ven ti la tor (UERV). Ap prov als The Unitized Energy Recovery Ventilator will con tain an en ergy re cov ery com po nent rated in ac cor dance with ARI Stan dard 1030-2000 with rat ings cer ti fied by ARI. Cabi net UERV shall be de signed to at tach di rectly to the a/c (roof top, up flow, hori zon tal) unit. It shall be G90 gal va nized ma te rial with a pow dered enamel paint fin ish elec tro stati cally bonded to the metal. Cabi net pan els where con di tioned air is han dled shall be fully in su lated to pre vent sweat ing and mini mize sound. Open ings shall be pro vided for power con nec tions. Lift ing de vices will be pro vided for rig ging. Test ports shall be pro vided so air flow can be meas ured across the energy recovery wheel. In take Air Blower (di rect drive) UERV shall con tain a cen trifu gal blower. All UERV s will be equipped with di rect drive PSC blower mo tors. Each mo tor will be mul ti ple speed and will be in di vidu ally con trolled. Air flow will also be ad just able by means of a damper on the in take air open ing. Blow ers and mo tors will be re mov able through means of a con nect ing plug for ease of serv ic ing. In take Air Blower (belt drive) UERV shall con tain a cen trifu gal blower. It shall have ball bear ings and ad just able belt drive. Mo tor mount base shall per mit ease of mo tor changeo ver and belt ten sion ad just ment. On piv ot ing wheel mod els, sup ply blower will be de- energized dur ing econo mizer op era tion. Ex haust Air Blower (di rect drive) UERV shall con tain a cen trifu gal blower. All UERV s will be equipped with di rect drive PSC blower mo tors. Each mo tor will be mul ti ple speed and shall be in di vidu ally con trolled. Blow ers and mo tors will be re mov able through means of a con nect ing plug for ease of serv ic ing. On piv ot ing wheel mod els, blower shall be sized to pro vide power ex haust dur ing econo mizer op era tion. Ex haust Air Blower (belt drive) UERV shall con tain a cen trifu gal blower. It shall have ball bear ings and ad just able belt drive. Moor mount base shall per mit ease of mo tor changeo ver and belt ten sion ad just ment. On piv ot ing wheel mod els, ex haust blow ers shall be sized to pro vide power ex haust dur ing econo mizer op era tion. Where sin gle blow ers can not pro vide ade quate ex haust, two blow ers will be util ized. One blower is en er gized dur ing en ergy re cov ery mode, and both blow ers are en er gized dur ing econo mizer mode. Energy Recovery Wheel The energy recovery device shall be a rotary heat exchanger per ARI Standard 1060 description. The device will be an enthalpy wheel coated with a silica gel desiccant by a patented process without the use of binders or adhesives which may plug the desiccant aperture. The substrate shall be a lightweight polymer. Desiccant shall not dissolve or deliquesce in the presence of water or high humidity. The wheel shall be easily cleanable with standard coil cleaning solution. On UERV s Series 20 and less, the wheel will easily be removable from the cabinet for cleaning. On UERV s Series 28 and above, the wheel will be provided with removable segments for cleaning and maintenance. All diameter and perimeter seals shall be provided. The energy recovery cassette shall be Underwriters Laboratories Recognized Component for electrical and fire safety. Balancing Dampers Balancing dampers will be provided for all R model stationary UERV s. These dampers will be mounted inside the rooftop air conditioning unit to adjust for the amount of exhaust air on packaged units. On pivoting wheel models, the unit economizer becomes the balancing damper. Upflow and horizontal UERVs will have the balancing damper provided in the UERV. Barometric Relief Dampers Barometric relief dampers will be provided in the exhaust air hood to prevent air infiltration when the UERV is de-energized. UERV Support All UERV s will be provided with support legs attached to the cabinet to support for the intake and exhaust end of the rooftop unit. Horizontal UERV s will be provided with support brackets for hanging. Filters All units shall be provided with mist eliminator type filters in the intake air hood. Power Connection The UERV shall be provided with a single point power connection for high voltage. Options: Optional UERV Equipment Support Furnish and install the optional equipment support for the intake and exhaust end of the unit. Optional Roof Mounting Frame Furnish and install the optional roof mounting frame to maintain proper height above the roof. Optional Low Ambient Kit Furnish and install the optional low ambient kit to prevent frost formation on the energy recovery wheel. Optional Motorized Intake Air Damper Furnish and install the optional motorized intake air damper. Optional Stop-Start-Jog On units without economizers furnish and install the optional stop-start-jog controls.