Application of Fuzzy Control in Central Air-conditioning Terminal Units Energy-saving

Similar documents
Construction of Wireless Fire Alarm System Based on ZigBee Technology

Research on the Monitor and Control System of Granary Temperature and Humidity Based on ARM

Design of Multi-Sensors Cooperation Control System for Intelligent Building

Design of an Infusion Rate Control System Based on Single Chip Microcomputer

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

A design of automatic boiler intelligent alert system based on the wireless AD hoc network

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

Design of the Fiber-optic Fence Warning System with Distributed Video Real-Time Display Function Qiang-yi YI and Zheng-hong YU *

A Design Method Based on Inherent Testability of Remote Control and Monitoring System for Marine Main Engine

Multi-sensor System For Indoor Environment Monitoring Zheng-yu Wanga, and Xiao-ru Zhangb

Android Controlled Fire Fighting Robot

The design of automatic remote monitoring system for the temperature and humidity based on GPRS Hui ZHANG 1, a, Honghua WANG 2,a

New fire control system design for fire fighting and rescue equipment Jianguo LUO1, a, Zehao BU2, b

Design of Intelligent Home Alarm System Based on ARM

Design of Intelligent Alarm System Based on GSM Network Shun Qing XU

Healthy. Atmosphere. for Pigs and Poultry. for a

The Design of Temperature Control System for Vegetable Greenhouse

Experimental Study of Initial Process of Frost on Heat Exchanger Surface of Refrigerated Transport Vehicle

WaterFurnace FX10 Application Guide Reversible Chiller

Design of Humidity Monitoring System Based on Virtual Instrument

Research on Evaluation of Fire Detection Algorithms

Design and Realization for the Environmental Protection Type of Pig-Farm Model Based on the Sensor Technology

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

"Three Preventions" System Design Based On Single-Chip Microcomputer (SCM) Control Jiaxiong Wen

Design of Microwave Anti-theft Alarm Based on Microcontroller

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

Precision Cooling. DataMate3000 Series Precision Cooling Systems for Small Equipment Room IT Application

The Development of Automatic Fire Alarm Standards and Related Products in China

Installation Guide for inbiox60 Series Access Control Panel

Installation Guide. Bacharach HGM300 to LonWorks FT-10 Communications Adapter

MECHANICAL SERVICES 101. Ian White

Industrial Ray DR/ ICT integration inspection testing system. (2) Software and Testing

GSM POWER ALARM SYSTEM

High-Performance, High-Reliability Gas Heat Pump

VMB1TSW Temperature sensor module for the Velbus system

Analysis of the Design of an HVAC System in a Public Building

RS485 MODBUS Module 8AI

Temperature and Humidity Monitoring System for Embedded Computer

,Chaojian He6, f. School of Guangxi University, Nanning , China.

Detection system for optic characteristics of automobile glasses

SCR100 User Manual. Version:1.1 Date:Dec 2009

Application of the VRV Air-Conditioning System Heat Recovery Series in. Interior Zone and Analysis of its Energy Saving

Design of Classroom Intelligent Lighting System Based on SCM. Jiale Zheng1, a

Intelligent monitoring system for automobiles

Best Row Number Ratio Study of Surface Air Coolers for Segmented Handling Air-conditioning System

Infrared Carbon Dioxide Sensor Module CM1106SL

Control System Structure

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

CFD Analysis of Fire Characteristics on Subway Junction Station

Design of Climatic Control Fan

All DC Inverter Multi VRF

Implementation of Auto Car Washing System Using Two Robotic Arms

The Mode of Urban Renewal Base on the Smart City Theory under the Background of New Urbanization

GB Translated English of Chinese Standard: GB

CASE STUDY AIR-CONDITIONERS

Hebei Datang International Wangtan Power Company, China

Engine Room Monitoring Alarm System Design and Implementation Xu Yuan, Ji Peng, Dai Yang, Ruan Shi-hao Abstract Key words:

Power Flame Incorporated

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

Design of Intelligent Humidity Sensing Watering System Based on MCU

Sensor Technology. Summer School: Advanced Microsystems Technologies for Sensor Applications

NEW LINE BOILER CONTROLLERS

THE FULL FORCED CONVECTION REFLOW SOLDERING SYSTEM SMT QUATTRO PEAK SERIES (FROM STO XLPLUS)

The Design of MLX90621 Based Intelligent Lighting Control System Hui-jiao Wang*, Meng-meng Liu and Cong-cong Shi

Development of a measurement and control system for a 10 K refrigerator based on Siemens PLC S7-300

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER

The Study of Low-Light Sights Reliability Test System in High and Low Temperature Environment

Addressable Fire Alarm Control System 2100 series

Autonomous Environment Control System using Fuzzy Logic

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

Flexible & Innovative. Cooling Solutions

The integral solution for. Air Handling Units. Technology & Evolution

Ultrasonic Parking Guidance System Program

*Corresponding author # Presenting author DOI: /jki th International Working Conference on Stored Product Protection

Study on an environmental simulation system of low/high temperature. for great space

AUTOMATIC STREET LIGHT CONTROL SYSTEM USING MICROCONTROLLER

LF /2. Fire Alarm Control Panel. Features:

gforce Units Data Aire and Data Temp Series

Job Name Control Systems Description Date

Hazardous Gas Detection using ARDUINO

Web Services are based on Apache and Tomcat servers. The html/jsp (tags, beans) are fully customisable and extendable.

Temperature Control of Heat Exchanger Using Fuzzy Logic Controller

A Real-Time Approach for Home Security and Alert System using CAN Protocol

Installation Summary - Dairy Plant

November 11, City of Sparks 215 S. 21 st St. Sparks, NV

BIOMEDICAL REFRIGERATORS

Wireless Sensor Network Based Bank Monitoring System Using LabVIEW

Methods of Software Integration of Alarm Systems

InBio X60 Series Access Control Panel User Manual

Datasheet: K-22 LO Sensor

Available online at ScienceDirect. New Framework of Intelligent Evacuation System of Buildings

opti-visor ultra-efficient chiller plant automation Typical specification

Patriot Systems Limited

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

Answers for infrastructure. HVAC control with Synco simple and energy-efficient

BRIDGE MONITORING. Picture 1: Benjamin Sheares Bridge

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

SUPREMATouch. Modular Fire & Gas Detection System

Transcription:

www.ijcsi.org 123 Application of Fuzzy Control in Central Air-conditioning Terminal Units Energy-saving Yanqiu Zhao 1, Yingli Lv 1, Yong Gu 1, Shucheng Liu 2 1 Department of Electrical Engineer, Hebei institute of Architecture and Civil Engineering, zhangjiakou, Hebei 075000, China 2 Zhangjiakou Administration of Work Safety Inspection zhangjiakou, Hebei 075000, China Abstract After introducing the central air-conditioning terminal units system, established a fuzzy control system based on Lonworks. System focuses on the design of fuzzy controller with intelligent nodes, Input signal of fuzzy controller were the concentration and concentration rate of CO 2, output signal was the volume of fresh air change, designed a two-dimension fuzzy controller. Based on the search results table, select adjust the fan speed or adjust fresh air valve opening, so as to minimize the amount of fresh air and meet the demands CO 2 concentration indoor, so as to achieve the objective of reducing energy consumption and improve air quality. Finally, the fuzzy control algorithm which offline calculated was downloaded to intelligent node, and through experiment verification of the control effect is good. Keywords:fuzzy control, central air-conditioning system, terminal units, energy-saving 1 Introduction In recent years, China's energy shortage will be the construction of energy-efficient referred to a crucial position, greatly promoted the central air-conditioning energy saving control technology development. Big, medium-sized central air-conditioning system by the refrigeration system, station, central air-conditioning unit; air conditioning water system; air conditioning terminal device ( fresh air machine, air handlers, fan coil ) is composed of three parts, the whole system power consumption mainly concentrated in the refrigeration system, station, central air conditioning, air conditioning terminal units.the refrigeration system of central air conditioning unit, pump stations and power consumption accounted for about 60%-65% of the total energy consumption of air conditioning, air-conditioning system energy consumption is the main part, so the research of energy saving control relatively mature; fresh air machine, air handlers, fan coil air conditioning system terminal equipment energy consumption accounts for about 35%-40% [1], and the terminal equipment main energy saving from material and structure and manufacturing aspects to improve the heat transfer efficiency of terminal equipment, therefore, the application of scientific method to control the air-conditioning equipment, effectively reduces the operation energy consumption, energy saving requirements in intelligent building and rapid development of the environment, it has practical significance [2]. 2 Terminal device of the entral air-conditioning installation overview 2.1 The composition and working principle of air machine Four common control of fresh air machine is mainly composed of fresh air valve, filter, heater, hot water coil, antifreeze switch,

www.ijcsi.org 124 chilled water coil, a humidifier, blower parts. Schematic diagram shown in Figure 1 below. air-conditioning room cold caloric requirements and the cold and heat source heat supply plays an important role in. At the same time, air conditioning room air through the air processor to control parameters. Air processor principle and structure as shown in Figure 2 below: Fig.1 Schematic diagram of composition four control ventilator Its working principle is: the operation of refrigeration, air valve opening, due to the fan suction effect, in the fresh air inlet to produce less than atmospheric pressure in the negative pressure, the external fresh air is inhaled fresh air machine, first through an air filter to filter, after the coil and coil cold water in the heat exchanger, cool air into oxygen, from the blower to the pressure after the wind pipe to the air conditioning room fan coil. Fresh air unit control including CO 2 concentration control, air temperature control, temperature control, indoor air relative humidity control, antifreeze control as well as various interlocking content. Air conditioning system in the operation, the room heat and moisture load and air quality with climate and indoor personnel changes, thereby causing the air to air demand are also different. Therefore, according to the load and air quality changes were adjusted to achieve the minimum fresh air volume, dynamic control, can ensure the indoor comfort requirements and achieve economic operation. The minimum fresh air volume may be determined according to the air conditioner end region of CO 2 concentration to set. In addition, the new air treatment means, the temperature and humidity independent control air conditioning system and. 2.2 The composition and working principle of air processor Air processor in central air conditioning is one of important terminal equipment, Fig. 2 four controls a return air processor structure diagram Primary return air system in summer air handling process is: to indoor air absorption room waste heat, residual wet, the return air duct to discharge to a part, another part back to the mixing tank and the outdoor fresh air mixture, and then after cooling treatment, release heat, and then by the blower into the air conditioning room, forming a cycle. Air processor needs to consider the factors controlling the indoor CO 2 concentration changes induced by air quality change; air conditioning cold, heat load changes caused by indoor temperature; air humidity load changes induced by indoor air humidity changes [2-3]. 3 System design For air conditioning system monitoring nodes, control process of complex features, using the most popular LonWorks field bus network. To establish a set of fuzzy control system based on Lonworks algorithm. System overall plan design as shown in Figure 3 below.

www.ijcsi.org 125 Fig. 3 the structure of fuzzy control system As of VB visual programming, event driven, object-oriented programming method and the support for DDE, using VB in PC development monitoring interface and fuzzy control procedures, so that the control system according to the change of load adjustment of cooling water pump and a freezing water pump and other operating parameters, to achieve the purpose of energy saving. Machine with Neuron C language simple fuzzy control procedures for the control of air conditioning equipment, to achieve the purpose of energy saving at the end. VB application in node remote control system functions are: the use of data bound controls from the network database to read out the control information, and sends the information to the input network variable form through the DDE Server passed to the Lon network nodes of the Neuron C control procedures, and the Lon network nodes can also be output through the DDE network variable Server upload to the network database, real-time refresh each node equipment information. 4 Design of fuzzy controller of intelligent node Central air-conditioning end should have temperature control, humidity control, volume control, air purification and other functions. In order to make these loads can be stable and efficient, we in the LonWorks control module is embedded in the neuron chip on the development of air conditioning terminal fuzzy control procedures, so that the control system can be separated from the PC machine work independently, can also be used by network variables and PC Lonworks DDE service program communication. 4.1 Design of fuzzy controller is offline According to the different design parameters, three offline fuzzy query table, this thesis focuses on the introduction of CO2 concentration control fuzzy controller design. Summer cooling, air wet heat treatment energy consumption greatly, in the protection of indoor air quality under the premise, if the fresh air volume is small, the more economy. Therefore, the fresh air volume is just equal to the interior demand, namely to meet air quality requirements of minimum fresh air volume determination, usually according to zone CO 2 concentration to set. According to the indoor air quality standards " GB\/T 17094-1997 " in regulation, indoor CO 2 concentration should be less than or equal to 1000ppm, " GB16153-1996 " specified in the restaurant CO 2 concentration should be less than or equal to 1500ppm [4]. Therefore, according to the area of the air conditioning function feature set a CO 2 concentration value as air quality control target, and in the air region of the appropriate positions in the set CO 2 concentration detector. The concentration of CO 2 target value is set to 800ppm. Set air conditioning terminal region of CO 2 concentration is Cco, then, when the detection of CO 2 concentration Cc>Cco, improve blower operating frequency, increase the quantity of fresh air, making the concentration of CO 2 decreased; when detecting the concentration of CO 2 Cc<Cco, reduce the blower operating frequency, reducing new volume, so that the increasing of CO 2 concentration. By dynamically adjusting the control, which can meet the demand of the minimum fresh air volume of fresh air supply, thereby greatly reducing the energy

www.ijcsi.org 126 consumption of fresh air handling and transportation energy consumption. Air quality control: when the detection of CO 2 concentration Cc>Cco, CO 2 concentration according to the size of the deviation, increasing the air valve, exhaust valve opening, while reducing air valve opening, to increase the quantity of fresh air, reducing the air supply volume, improve the fresh air ratio, the concentration of CO 2 decreased, until the Cc=Cco; when detecting the concentration of CO 2 Cc<Cco the concentration of CO 2, according to the size of the deviation, the appropriate reducing new air valve, exhaust valve opening, while increasing the return air valve opening, to cut new volume, increased back to the air, reducing fresh air ratio, the concentration of CO 2 increased, until Cc=Cco. According to the concentration of CO 2 the size of the deviation, control of fresh air, exhaust air, return air three air valve opening, to regulate fresh air, return air volume mixing ratio, it can control the concentration of CO 2, to meet air conditioning comfort on air quality requirements [5]. The system is based on the CO 2 concentration and CO 2 concentration change rate as input, to the new air change rate of output, the design of a two-dimensional fuzzy controller. According to the above parameters, the control rules of fuzzy controller, and then through the fuzzy and fuzzy decision, fuzzy control table. Concrete structure diagram as shown in Figure 4 below, according to a look-up table results, namely new air change volume selection to regulate fan speed or regulate fresh air valve opening, wherein the air valve and air valve opening design for linkage control, when the fresh air valve opening is increased, corresponding reducing return air valve opening. Fig. 4 CO 2 concentration control fuzzy controller 4.2 Fuzzy controller for download Application method of look-up table of fuzzy control, the off-line calculated from the terminal equipment of the fuzzy control algorithm is downloaded to the nodes, the fuzzy control table is stored in the CPU Flash Rom, realize the so-called local autonomous control, each internal node has made the realization of specific functions of the software, the device can adjust the parameters, each intelligent node can communicate with the network in the form of variables, forming site coordination control, and through the network interface to the PC real-time data transmission [6]. The fuzzy controller is made up of five placed directly at the site of the nodes, sensor input node completes the temperature, humidity and the concentration of CO 2 network variable output, controller node receives from the sensor node on-site detection signal, the realization of three kinds of fuzzy control algorithm, and outputs the correction network variables; the actuator to drive the end air valve, to reach the proper opening or change the rotating speed of the fan. Nodes with twisted pair physical connection node communication, information may also be transmitted to the host PC to achieve real-time monitoring [7]. Node fuzzy controller network variable connection and function distribution as shown in Figure 5 below:

www.ijcsi.org 127 Fig. 5 node fuzzy controller network variable connection and function allocation 4.3 The effect of fuzzy control In summer, the designed fuzzy controller used in central air conditioning system of experiment, the indoor temperature setting target value is 26, CO 2 concentration target value is set to 800ppm, the fresh air valve opening degree of setting an initial value of 20%, return air valve opening of the initial value of 80%, set the indoor relative humidity control is in the range of 45%~65%. Control effect as shown in Figure 6 below. Fig. 6 CO 2 concentration fuzzy control curve Figure 6 shows, in 100 minutes, indoor CO 2 concentration close to the 800ppm, and basically stable in the vicinity of. The control results show that, by use of the fuzzy control can make the concentration of CO 2 stability in near a predetermined value, small steady-state error, good control effect. 5 Conclusions With the development of intelligent control theory and the energy conservation and environmental protection requirement, the construction of a high energy consumption of air conditioning system has put forward higher requirements. As a result of fuzzy control and LonWorks technology advanced, they increasingly wide range of applications. The project will be the two technologies are combined, the intelligent node using fuzzy control technology for air conditioning terminal system for good and efficient operation, the system achieved a full range of energy saving. References [1] Li Yujie,in central air conditioning system energy saving fuzzy control technology and its application [M], China Building Industry Press, 2009 [2] Xu Xiaoning,Ding Yunfei, At the end of the central air-conditioning equipment intelligent control and energy-saving management [J], building science, 2008.8,43-46 [3] Stjepan Bogdan,Model predictive and fuzzy control of a road tunnel ventilation system[j], Transportation Research Part C 16 (2008),574-592 [4] Liu Jingwan, Variable air volume air conditioning fuzzy control technology. China Building Industry Press [M], 2011 [5] Ma Li. Intelligent control with the development of network technology and [M] LON [M], Beihang University press, 2003 [6] Chang Xianwen,Ji Zhaoliang. Intelligent control technology in energy saving of central air-conditioning system in the application of [J], building energy conservation, 2007 tenth period, 4-8 [7]Li Shujiang,Li Nan, Central air-conditioning terminal controller based on GSM research, application of electronic technology in 2009 ninth stage [J],50-53 Author Yanqiu Zhao, received the Master degrees from Hebei institute of technology of department automation, Tangshan, China, in 2006. Currently she is an lectorate at the Hebei institute of Architecture and Civil Engineering, Zhangjiakou, China. Her current research interests include intelligent control, electrical automation system Yingli Lv Currently she is an lectorate at the Hebei institute of Architecture and Civil Engineering, Zhangjiakou, China. Her current research electrical automation system

www.ijcsi.org 128 Yong Gu Currently he is an lectorate at the Hebei institute of Architecture and Civil Engineering, Zhangjiakou, China. He current research electrical automation system Shucheng Liu Currently he work at the Administration of Work Safety Inspection, zhangjiakou, Hebei, China. He current research computer control system