PRODUCT MANUAL FIRE EXTINGUISHER

Similar documents
PRODUCT MANUAL FIRE EXTINGUISHER. Carbon Dioxide 6.5, 9 & 22.5 Kg Capacity Trolley Mounted (45 kg also as a non standard)

Institute for Plasma Research Welcomes you all on

Technical Data Sheet No. JS-SM-40 DOCUMENT TITLE 2.0 LITRE STORED PRESSURE WET CHEMICAL FIRE EXTINGUISHER

Technical Data Sheet No. JS-SM-33 DOCUMENT TITLE. 2.0kg ABE TYPE STORED PRESSURE DRY POWDER PORTABLE FIRE EXTINGUISHER MODEL: R2.

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL

TRAINING BULLETIN TOOLS 1 May 27, 2011 PRESSURIZED WATER EXTINGUISHER

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 7 Extinguisher Types Revised

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

Safety Policy and Procedure

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

DRY POWDER FIRE EXTINGUISHER (Stored Pressure) ABC TYPE - PORTABLE

WHEELED STORED PRESSURE

GUILFORD COUNTY SCHOOLS

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

Twin-Agent Fire Fighting/Securing Systems Specifications

FIRE EXTINGUSIHER INSPECTION, MAINTENANCE, AND TESTING PROCEDURES

Aldine Independent School District Aldine Westfield Road Houston, Texas Phone (281)

TRAINING BULLETIN September 1, 2010 PURPLE K DRY CHEMICAL EXTINGUISHER 1. INTRODUCTION

WHEN a fire starts, the first few seconds are critical. Thus, fire

OWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE

Technical Data Sheet No. JS-SM-38 DOCUMENT TITLE 3.5KG CARBON DIOXIDE FIRE EXTINGUISHERS

Fire, extreme heat, smoke, toxic fumes, noise, falling objects, uneven terrain, debris,

Extinguishers. Commercial Industrial High rise buildings

FIre Extinguishers. K-GUARD Wet Chemical Fire Extinguishers Manual INSTALLATION 2014-DEC-29 REV. 03 PAGE 1 EXTINGUISHERS

Portable Fire Extinguishers

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

CHAPTER 15: FIRE PREVENTION & AWARENESS POLICY

"USING FIRE EXTINGUISHERS"

WHAT IS FIRE? In order to have a fire, there must be three elements: Heat -- enough to make the fuel burn

Portable Fire Extinguishers

Fire Extinguisher Use. Fire Extinguisher Review. and Fire Safety

COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST

OPTIONAL INFORMATION PORTABLE FIRE EXTINGUISHERS SELF INSPECTION CHECKLIST

Using Fire Extinguishers. Leaders Guide and Quiz

SOUTH AFRICAN NATIONAL STANDARD

Fire Safety. Presenter, Kevin V Coleman September 14 th 2016

CIRRUS AIRPLANE MAINTENANCE MANUAL

PORTABLE SMART WASHER

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

FIRE TETRAHEDRON. Consists of 4 Sides. Oxygen. Fuel. Chain of reaction

Subchapter 7. General Industry Safety Orders Group 27. Fire Protection Article 157. Portable Fire Extinguishers. Return to index New query

Leader s Guide 2007 CLMI Training

Fire Safety PPT-SM-FIRESFTY V.A.0.0

SECTION AUXILIARY HEATER

Model Policy On Portable Fire Extinguishers (Ontario Version)

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION

Progressive Safety Services LLC 2

Fire fighting Portable fire extinguishers Performance and construction

Fight or Flee? Extinguisher Basics Extinguisher Use Extinguisher Placement and Spacing Hydrostatic Testing OSHA Requirements Test Your Knowledge

OWNERS SERVICE MANUAL

FIRE SAFETY PRACTICES AND PROCEDURES

Risk Management Resources

Salt Lake Community College FIRE EXTINGUISHER TRAINING

Model HD 3000 Part No High Pressure Washer Operator Manual

DC3Training.com N28AA DC-3 Pilot s Handbook

A full range of UK manufactured portable and wheeled fire extinguishers

ONE PIECE TOILET LT3. Model: MPN: B0940 INSTALLATION INSTRUCTIONS. Version: 1.0

CARTRIDGE EXTINGUISHER

HIGH SPEED BURNISHER VF53023CP rev.01 ( ) MODE D L E # CPL C 1500H 0 S SERI R AL A #

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

4NEK5 High Speed Burnisher TABLE OF CONTENTS

TAMUCC Fire Safety Training

HIGH SPEED BURNISHER OWNERS MANUAL

CL & CLG Clamp Mount Mixers

Flammable liquids, gasoline, oil etc. Advantages. 21 B. Ø 920 mm 21 B. Ø 920 mm

HIGH PERFORMANCE HEAVY DUTY INDUSTRIAL STORED PRESSURE

June 2013 Safety Meeting Fire Extinguishers Part II

INSPECTOR I SKILLS ADMINISTRATION

High Pressure Washer Operator Manual. Specifications Model HD 2700 DH/DB

Model K 5800 G Part No

FIRE SAFETY. This easy-to-use Leaders Guide is provided to assist in conducting a successful presentation. Featured are:

OWNER S MANUAL IMPORTANT: READ OWNER S MANUAL CAREFULLY

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers

Model K205 M Plus Part No

VIPER VENOM HIGH SPEEDS OWNERS MANUAL. IMPORTANT: READ OWNERS MANUAL CAREFULLY Please fill out & return your warranty card! VN1500 SERIAL# MODEL#

Model K 4400 G Part No High Pressure Washer

Model K 280 M Part No

1 L Rotary Vacuum Evaporator Instruction Manual

DRY CHEMICAL AND CLEAN AGENT HAND PORTABLE FIRE EXTINGUISHERS

Aerosol Type Fire Extinguisher Aerosol Type Fire Extinguisher

EH W Pressure Washer

Tender document for Supply/ Installation of New Fire extinguishers & Refilling TENDER NOTICE

U.S. Consumer Product Safety Commission Washington, DC 20207

HydroFlux Welder Torch System T0-102 / T0-103

FIRE EXTINGUISHER. Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley Extinguishers

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

w w a. m o c. x e r fi. w u

Inert Gas Fire Extinguishing System

Emergency Response Procedures Contractors Instruction. Building nformation

Model HD 3501 Part No High Pressure Washer Operator Manual

FIRE EXTINGUISHERS. Chapter 2. - Co2 Fire Extinguisher - Dry Foam Fire Extinguisher - Foam Fire Extinguisher - Portable Foam Applicator

π H-7147 SANITAIRE EON QUIET CLEAN VACUUM SAFETY uline.com

Table Top Patio Heater

Model K 3000 G Part No

COMPONENT MAINTENANCE MANUAL

Rambo CAST IRON RING BURNERS OPERATING INSTRUCTIONS. C40LP 3 Ring Burner C50LP 4 Ring Burner

OWNERS SERVICE MANUAL NO INSTALLATION, OPERATING & SERVICING INSTRUCTIONS

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Fire fighting Questions

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

Transcription:

PRODUCT MANUAL FIRE EXTINGUISHER Clean Agent (FE-36) 2, 4 & 6 Kg Capacity Kanadia Fyr Fyter Pvt Ltd Laxminagar, Ghatkopar (E), Mumbai -400 075 Page 1 of 5

INTRODUCTION [KANEX FIRE EXTINGUISHER] Store Pressure (CLEAN ( AGENT (FE ( FE-36 36)) 2, 4 & 6 Kg Capacity This manual contains product description, installation, operating, maintenance, inspection and refilling for the KANEX brand Portable Stored pressure CLEAN AGENT (FE-36 ) type Fire Extinguisher of capacity 2, 4 or 6 Kg by weight of Charge. This model is designed to extinguish A, B and C type fires involving material like Wood, Paper, Cotton, Petro Chemical products, Paints, Resins, Pigment, Varnish, Gases in the compressed form like Oxygen, Acetylene, LPG, CNG and Electrical as well as electronic equipments. PRODUCT DESCRIPTION The principal advantage of KANEX Portable type Stored Pressure CLEAN AGENT (FE-36) type Fire Extinguisher is that the fire extinguisher is handy type and it is easily handled by a single person. Body Shell made of Mild steel/ss sheet is constructed by welding and the shape of the body is cylindrical. The domes ends of the body are dished outwards. The charge, Clean Agent (FE-36) is an extinguishing media that gives blanketing effect on the fire to be put out. The Charge is actuated by N 2 gas stored in the container. The discharge of the Charge is by squeezing the lever of control valve. The Valve is made of forged Brass material. A Pressure gauge is attached to the valve body for inspection of in built pressure. The needle in the green zone in the dial of pressure gauge is the readiness of the extinguisher to be operated. The needle shifted in the red zone is an indication of under or excess pressure in the container and to refill the extinguisher. KANEX clean Agent extinguishers have effective extinguishing agent, environmental acceptable and excellent substitute of Halon 1211. FE-36 extinguishing agent is a non corrosive, electrically non-conductive and free to residue. FE-36 Clean Agent identified as HCFC Blend E from the US EPA. FE-36has been carefully formulated in order to optimize both the physical and extinguishing characteristics. The ingredients used in FE-36 have been evaluated under the PAFT (Program for Alternative Fluorocarbon Toxicity testing) chronic toxicity testing program and have been confirmed to have no known chronic toxicity.. FE-36 Clean Agent gas is listed under USA Signification New Alternative Policy (SNAP) and approved by US EPA (Environmental Protection Agency). It is colorless. Page 2 of 5

INSTALLATION Installation of the KANEX Fire Extinguisher requires that the equipment be uncrated, placed in its proper position and secured in place with caster locks. One set of accessories is packed with fire extinguisher for use in installation either attached with the body or loose in a packet. Please compare your supplied accessories with the following list. Discharge Hose Pipe (300 mm for 2 Kg. 465 mm for 4 Kg capacity & 6 Kg capacity) Belt (For capacity 4 & 6 Kg) Wall Bracket To assemble the Fire Extinguisher, Connect the nozzle or Hose Pipe to the valve. Rotation required connecting the nozzle or hose is in clockwise direction Provide the belt to the body at Bottom circumferential welding joint Keeping PVC discharge horn (open end of the hose) into the belt arms, tighten the nut bolts of Belt Ensure that the all above parts are firmly tightened with each other Affix the wall bracket ensuring adequate strength to the wall For installation pick up a convenient distance that shall not be longer than 15 meter from site and such a way that fire extinguisher can be easily driven from that location while required to fight with fire. OPERATION To be operated the Kanex fire extinguisher is held in an upright position The Discharge Hose is hold firmly in the hand. The safety sealing device is removed The locking pin is pulled The Lever of Valve is squeezed The discharge should be directed at the base of the flames On fires involving electrical or electronics equipments, discharge should be directed at the source of the flames. There are two methods of directing the discharge to adopt the better extinguishment a) The most commonly used method of agent application on contained flammable liquid fires is to start at the near edge and direct the discharge in a slow, side-to-side sweeping motion, gradually progressing toward the back of the fire. b) The other method is called Over head application. The discharge nozzle is directed in a dagger or downward position (at an angle of 45 degrees) toward the center of the burning area. Page 3 of 5

Generally, for spills fire, the side-to-side sweeping motion could give better results. The discharge should be applied to the burning surface even after the flames are extinguished to allow added time for cooling and to prevent possible reflash. PRINCIPALS OF OPERATION The Clean Agent( FE-36) agent extinguishes by blanketing on the Fire surface so that the oxygen levels are kept below the percentage required for combustion. The method of expulsion of Charge is by dry Nitrogen pressure stored in the fire extinguisher itself. The control discharge of the Charge is obtained by use of the spring loaded squeeze grip. The discharge time for KANEX brand Portable type Clean Agent (FE-36) type Fire Extinguisher for 2 Kg varies from 8 to 12 second. The discharge time for the capacity 4 Kg varies from 8 to 14 seconds & for capacity of 6 Kg varies from 8 to 22 seconds. The discharge jet range of the discharge stream is more than 2 meter for 2 Kg and 3 meter for capacity of 4 Kg and 6 Kg. The percentage discharge of the extinguishing media is more than 95 %. INSPECTION, MANINTENANCE AND RECHARGING The owner or the designated agent or occupant of a property in which fire extinguishers are located shall be responsible for inspection, maintenance and recharging. INSPECTION: Fire Extinguisher shall be inspected when initially placed in service and then after at approximately 30 day intervals for routine maintenance. The inspection should be in following points of view. Safety Seals not broken or missing Visually damage, corrosion, leakage or clogged discharge connection Condition of nozzle, Hose Pipe, valve, wall bracket and fire extinguisher itself Inspection of the needle of pressure gauge (If the needle shifts to the red zone, send the extinguisher for refilling) RECHARGING: It is important to reenergize the Fire Extinguisher as soon as possible to eliminate the potential of recombustion or fire. Each fire extinguisher shall have a tag or label securely attached that indicates the month and year recharging was performed and that identifies the person performing the service. It is essential to recharge the fire extinguisher as soon as the extinguisher is used for either extinguishing the fire or used for demonstration. The extinguisher must be recharged at a stipulated time duration that is a due of refilling. Page 4 of 5

[Clean Agent (FE 36)- Portable (Capacity 2 Kg)] 01 Body M.S. 01 No. 02 Valve Brass 01 No. 03 Neck Ring M.S./SS 01 No. 06 Wall Bracket M.S. 01 No. 08 Clean Agent (FE 36) HFC 236fa 02 Kg Fire Extinguisher Part List [Clean Agent (FE 36)- Portable (Capacity 4 Kg)] 01 Body Shell M.S./SS 01 No. 02 Valve body Brass 01 No. 03 Neck Ring M.S./SS 01 No. 06 Mounting Bracket M.S 01 No. 08 Clean Agent (FE 36) HFC 236fa 04 kg [Clean Agent (FE 36)- Portable (Capacity 6 Kg)] 01 Body Shell M.S. 01 No. 02 Valve body Brass 01 No. 03 Neck Ring M.S. 01 No. 06 Mounting Bracket M.S 01 No. 08 Clean Agent (FE 36) HFC 236fa 04 kg Page 5 of 5