Roof Fan DVG EC. Smoke extraction and daily ventilation in one!

Similar documents
Roof Fan DVG EC. Smoke extraction and daily ventilation in one!

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

The Straight Way K Sileo Series

When you think safety think Systemair

Domestic & Commercial Fans

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

UNIJET CAR PARK VENTILATION SYSTEM

RS /E-EV C01 SERIES

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Series VENTS VUT R WH ЕС

Systemair product news - Fans NEWS

Ionisation single-tube smoke detector for duct mounting

ROOFMASTER STEF-HT ROOF FAN

KOMFORT EC DB Suspended heat recovery air handling units

RS /E-EV C01 SERIES

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

TopVent Design Handbook

APPLICATION DATA SHEET

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units

LOW NOx MODULATING GAS BURNERS

Air curtain.

Pre-programmed room controller with communication

TUNNEL FANS STANDARD AND HOT SMOKE

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S

Instructions for the fan motor control system, SILVER C

Product Data Sheet Adsorption Dryer DPS (A)

PHOTOELECTRIC AMPLIFIER SERIES

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator Healthcare

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

Pre-programmed room controller with communication

Instructions for the fan motor control system with integrated wiring terminals SILVER C

DVG. Installation and Operating Instructions for Anvisningar för montering och drift Инструкция по установке и эксплуатации. English Originalversion

GB Art. Nr

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

Pre-programmed room controller with communication and hidden setpoint

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Topvex SF02-SF12 Air Handling Unit

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

INDUSTRIAL AIR CURTAIN. IndAC 2

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС

Pioneer-R16 Gas Monitor Operator s Manual

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

The new Xcell EC High Efficiency Range Fresh air pure and simple

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Dräger Polytron 8000 Stationary gas detector (EC)

PolyGard 2-channel Gas Controller MGC-03

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator School

/8 DIN Level Indicator

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

Analog Annunciator Unit SACO 16 A3. Product Guide

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Wall fans. High air performance and low energy consumption

K Series CK-25 N CK-35 N CK-40 F CK-50 CK-60 F ECO-500 KITCHEN EXTRACTORS. Kitchen extractors CK

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator Office

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

CN7232 Advanced Garage Ventilation Controller

KITCHEN EXTRACTORS CK Series Plastic range CK-60 F CK-40 F CK-25 N

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

Advantages / Characteristics

Original instructions AR

APPLICATION DATA SHEET

ExPolar Heating System

CVE ECO 2 Range. System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible

Recalibrate the way you look at gas detection

Lo-Carbon Sentinel Kinetic Horizontal

Dräger Polytron 8310 IR Detection of flammable gases and vapour

AXIAL FANS USER S MANUAL

MiLAB Oxygen Control MANUAL & INSTALLATION. MOC-100 Ver 3.0

gas monitoring system

Lonworks Damper Interface Catalogue

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

S F IT 6" / 8"HES. Quick Installation Guide. franklinwater.eu

Axial fans The right fan for every house

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

MRXBOXAB-ECO3 MRXBOX-ECO3

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Danfoss Air Heating Surfaces

MRXBOXAB-ECO2 MRXBOX-ECO2

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Transcription:

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Roof Fan DVG EC Smoke extraction and daily ventilation in one! C/12min 12 C

2 Roof Fan DVG EC Roof Fan DVG EC Pstat 12 11 1 9 8 7 6 Quick selection C/12min 12 C Q 8 12 16 2 2 28 DVG-H EC DVG-V EC 8 Normal ventilation + smoke and heat extract unit (dual use) Up to C / 12 min (F/12, F/9, F, F2) Normal ventilation up to 12 C continuous operation, up to 8 C in standstill (when the fan doesn`t operate) Horizontal (DVG-H) exhaust or vertical exhaust (DVG-V) Service switch serial Suitable for coastal applications Wide range of accessories Tested acc. to EN 1211- at LGAI, Barcelona CE-certification acc. to EN 1211- Meet ErP efficiency goal for dual use fans 1~ (2-26V, /6Hz) or ~ (2-6V, /6Hz) EC (electronically commutated) high efficiency motor -1V speed control input Modbus control possible Fire mode integrated Ten models available, five for vertical and five for horizontal exhaust. The DVG smoke extract fans are used in case of fire to extract smoke gases from rooms, and also during normal working conditions for standard ventilation. Smoke-free escape ways increase the chances to rescue people in case of fire. For installation only on top of heated buildings. The casing is manufactured from seawater resistant aluminium. The base frame consists of galvanised steel. The impeller with backward curved blades is manufactured from galvanised steel. Motor outside air stream is cooled with fresh air. 2 1 6 6 1.11 2.22...6 6.67 7.78 Q Technical data Item No. Model Nominal voltage Input power P1 [kw] Current [A] Max. airflow R. p. m. [min -1] Sound pressure level at /1 m [db(a)] Weight [kg] Wiring diagram 921 DVG-H EC/F 1~2V, 1,8 2 1 9/ 1 WD1 922 DVG-H EC/F 1~2V,92 62 1 67/6 WD1 92 DVG-H 6EC/F ~V 2,2,7 11 1 7/69 11 WD2 92 DVG-H 6EC/F ~V,6 8 192 1 78/72 11 WD2 92 DVG-H 8EC/F ~V,86 7,7 276 9 81/72 192 WD2 926 DVG-V EC/F 1~2V, 1,8 1 1 6/ WD1 927 DVG-V EC/F 1~2V,92 8 1 6/8 7 WD1 91 DVG-V 6EC/F ~V 2,9,8 12 1 72/67 16 WD2 916 DVG-V 6EC/F ~V, 8 182 16 7/69 11 WD2 917 DVG-V 8EC/F ~V,79 7,7 21 9 7/66 199 WD2 Insulation class, motor F; enclosure class, motor IP

Roof Fan DVG EC Dimensions Accessories DVG EC A B ø E F G ø df (nxm) H1 H 98 12 1 7 8 (6xM8) 67 668 12 1261 8 8 (6xM8) 67 6 9 7 1 1 178 6 (8xM8) 77 6 19 8 1 17 172 67 (8xM8) 88 8 12 1 1 22 128 872 (8xM8) 999 SSGE/F socket silencer DVG-V/F DVG-H/F FDGE/F roof socket FDG/F flat roof socket SSG/F socket silencer ASG/F inflow box ASFV Flange DVG installation examples VKG/F shutter DVG-V DVG-V ASSG/F flexible connection SSG/F Roof base Silencer with silencer ASG/F Inlet chamber VKG/F Automatic shutter ASSG/F Flexible connection DVG-V VKG/F Automatic shutter ASSG/F Flexible connection FDG/F Roof Silencer base DVG-V FTG tilting device (for and, if not intended for fire ventilation) VKG/F Automatic shutter SSG/F SSG/F Roof base with silencer Silencer ASG/F Inlet chamber ASSG/F Flexible connection VKG/F Automatic shutter SSGE/F (FDGE/F) Roof Silencer base with/ without silencer ASG/F Inlet chamber ASSG/F Flexible connection

Roof Fan DVG EC Diagrams with dashed system curves Horizontal exhaust DVG-H EC 1 2 DVG-H EC/F 2 1.2..7 1 8 2 6 1 8 12 DVG-H EC/F DVG-H 6EC/F 6 7 2 2. 1 1. 2 1 2 12 1 1 2 1 1 1 2 2 DVG-H 6EC/F DVG-H 8EC/F 9 7 6 2 2 6 2 6 8

Roof Fan DVG EC Vertical exhaust DVG-V EC 1 2 DVG-V EC/F 2 1.2..7 1 8 2 6 1 8 12 DVG-V EC/F DVG-V 6EC/F 6 7 2 2. 1 1. 2 1 2 12 1 1 2 1 1 1 2 2 DVG-V 6EC/F DVG-V 8EC/F 9 7 6 2 2 6 2 6 8

6 Roof Fan DVG EC Examples of use Beside smoke and heat extraction, DVG EC can also be used for other ventilation purposes Intelligent control system can also control demand fan operation, based on external sensor demands (CO,, humidity, temperature,...). Industry, Car Park Systems Healthcare, Fitness, Gyms Shopping Malls, Showrooms, Kitchen exhaust CO % C

Roof Fan DVG EC 7 DVG EC connection example Fan electronics PC SCADA Modbus Monitoring DVG EC Roof socket Controller for CO level Max. kapacity in case of fire Daily ventilation IR-Fire detector Smoke detector Fire Smoke CO sensor GARAGE Fire alarm system

8 Roof Fan DVG EC Wiring diagrams WD1 (1~2V) Power supply - connection in service switch Control cables - connection in EC controller EC motor prewired WD2 (~V) Control cables - connection in EC controller EC motor prewired Power supply - connection in service switch Connection Functions Max. crossection of power supply wires: 2, mm 2 ( mm 2 without core end sleeves) Cable glands on service switch for power supply: 1xM2x1, Service switch ON-OFF, 6-pole + 1x NC Max. crossection of control wires: 1, mm 2 Cable glands of control part: 2x M2x1, F1 Fault relay F2 Analog input for set value / speed setting F Potentiometer for speed setting F External sensor F Speed output F6 FIRE mode (open = FIRE) F7 Start / Stop switch (open = stop) F8 Modbus connection

Roof Fan DVG EC 9 Electrical accessories - connection examples If the fan is supposed for fire ventilation too, switch to fire mode must be controlled by fire control system. Electrical accessories Accessories (sensors with output -1V) for daily ventilation, controlled by internal PI regulator (integrated in fan) Setup of internal PI regulator via modbus. For use of internal PI regulator two analog signals (-1V) are needed. First one, which defines target (set point) value of regulated property (temperature, humidity, CO2,..) with analog signal connected to AN1 (connection 7 at 1~, 6 at ~) Second one, which defines actual measured value of regulated property (temperature, humidity, CO2,..) with analog signal from sensor, connected to AN2 (connection 11 at 1~, 8 at ~) Temperature controler AL2A1T Systemair-E-D, humidity, temperature sensor Temperature controller AL2A1T Item no. 921 C DSG 2,, 1 differential pressure sensor 7 6 8 1 2 V AC supply 2 System neutral 2 V AC (G+) output, for actuator supply -point output increase -point output decrease 6 1 V DC control output 7 Signal neutral 8 Change-over input 9 Occupancy input 1 External sensor Differential pressure transmitter with built-in PID cotroller MTP 2 on/off, -step manual speed controller / humidity / temperature Systemair-E-D Item no. 19 % C MTV-1/1 controller for manual speed control 12 9 TEMP 1 2 6 7 12 9 or RH% 1 2 6 7 12 9 or CO2 1 TEMP, -1V/-2mA (Jumper) 2 COM/GND RH%, -1V/-2mA (Jumper) - PT 1 + 6 CO2, -2mA 7 COM/GND 8 8 8 CO2, -1V/- (Jumper) MTP 1 Potentiometer for manual speed control CO2RT-R-D sensor Differential pressure DSG 2 DSG Item no. 169 Item no. 17 DSG 1 Item no. 966 EC-Vent control board 1 11 12 9 +2V Brown Output +...1V DC Yellow White + - EC-Vent room unit

1 Roof Fan DVG EC Accessories with built-in PID controller + 12 9-1V DC - IN 2V AC/DC 1 2 6 7 8 9 Differential pressure transmitter with built-in controller with selectable range...1/ / / 1 Pa DMD-C Item no. 179 Accessories for manual control of speed for daily ventilation step manual controller (2 speeds adjustable) MTP 2 Item no. 122 Controller for manual speed control MTV-1/1 Item no. 6 1 7 12 9 - + 1 2 12 9 IN 2V + -1V DC - 1 2 Potentiometer for manual speed control MTP 1 Item no. 271 1 2 Us + - 18 19 1 9 8 11 12 7 6 Accessories for daily ventilation (switches ON-OFF) / Temperature - sensor with built-in relay CO2RT-R-D Item no. 699 C 18 12 19 11 Common Normally open 1 Supply voltage 2 V AC 2 System neutral 2 V AC Normally closed

Roof Fan DVG EC 11 EC Vent % % C C EC-Vent Room Unit Item no. 18 EC-Vent control board Item no. 11 ~ 1~ 6 7 8 Regin CO2RT-D PT 1 PT 1 Signal neutral Out...1V DC CO2 Out...1V DC temperature Out...1V DC humidity System neutral Supply voltage 2V AC/DC 8 7 6 2 1 The wiring of 1~ DVG EC and EC-Vent (the wiring of ~ DVG EC is analogue) The markings of EC-Vent as in instruction (A = power supply, RU = room unit, CB = computer board)

www.systemair.com Systemair d.o.o. May 21