Roof Fan DVG EC. Smoke extraction and daily ventilation in one!
|
|
- Ami Burke
- 5 years ago
- Views:
Transcription
1 Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Roof Fan DVG EC Smoke extraction and daily ventilation in one! C/12min 12 C
2 2 Roof Fan DVG EC Roof Fan DVG EC Pstat Quick selection Q DVG-H EC DVG-V EC Q Technical data C/12min 12 C 8 8 Normal ventilation + smoke and heat extract unit (dual use) Up to C / 12 min (F/12, F/9, F, F2) Normal ventilation up to 12 C continuous operation, up to 8 C in standstill (when the fan doesn`t operate) Horizontal (DVG-H) exhaust or vertical exhaust (DVG-V) Service switch serial Suitable for coastal applications Wide range of accessories Tested acc. to EN at LGAI, Barcelona CE-certification acc. to EN at BSI, UK Snowload DVG-H SL 1 Snowload DVG-V SL (for installation on top of the heated buildings) Meet ErP efficiency goal for dual use fans 1~ (2-26V, /6Hz) or ~ (2-6V, /6Hz) EC (electronically commutated) high efficiency motor -1V speed control input Modbus control possible Fire mode integrated Speed regulator (HEATing or COOLing) built-in: AN1 - set point, AN2 - sensor (PI setting via Modbus) RPM - skipping to reduce possible resonance Ten models available, five for vertical and five for horizontal exhaust. The DVG smoke extract fans are used in case of fire to extract smoke gases from rooms, and also during normal working conditions for standard ventilation. Smoke-free escape ways increase the chances to rescue people in case of fire. The casing is manufactured from seawater resistant aluminium. The base frame is made of pre-galvanized steel, zincmagnesium (ZM) coated. The impeller with backward curved blades is manufactured from pre-galvanized steel (sizes, ), respectively from steel, welded and galvanized (sizes 6 to 8). Motor outside air stream is cooled with fresh air. Connection to power supply in the service switch, connection to controller in the connection box on the casing. Item No. Model Nominal voltage Input power P1 [kw] Current [A] Max. airflow R. p. m. [min -1] Sound pressure level at /1 m [db(a)] Weight [kg] Wiring diagram 921 DVG-H EC/F 1~2V, 1, / 1 WD1 922 DVG-H EC/F 1~2V, /6 WD1 92 DVG-H 6EC/F ~V 2,2, /69 11 WD2 92 DVG-H 6EC/F ~V, /72 11 WD2 92 DVG-H 8EC/F ~V,86 7, / WD2 926 DVG-V EC/F 1~2V, 1, / WD1 927 DVG-V EC/F 1~2V, /8 7 WD1 91 DVG-V 6EC/F ~V 2,9, /67 16 WD2 916 DVG-V 6EC/F ~V, /69 11 WD2 917 DVG-V 8EC/F ~V,79 7, / WD2 Insulation class, motor F; enclosure class, motor IP
3 Roof Fan DVG EC Dimensions Accessories DVG EC A B ø d F G ø d (nxm) ø duct H1 H E (6xM8) (6xM8) (12xM8) (12xM8) (16xM8) SSGE/F socket silencer DVG-V/F DVG-H/F FDGE/F roof socket d d FDG/F flat roof socket SSG/F socket silencer ASG/F inflow box ASFV Flange VKG/F shutter DVG installation examples DVG-V DVG-V ASSG/F flexible connection SSG/F Roof base Silencer with silencer ASG/F Inlet chamber VKG/F Automatic shutter ASSG/F Flexible connection DVG-V VKG/F Automatic shutter ASSG/F Flexible connection FDG/F Roof Silencer base DVG-V FTG tilting device (for and, if not intended for fire ventilation) VKG/F Automatic shutter SSG/F SSG/F Roof base with silencer Silencer ASG/F Inlet chamber ASSG/F Flexible connection VKG/F Automatic shutter SSGE/F (FDGE/F) Roof Silencer base with/ without silencer ASG/F Inlet chamber ASSG/F Flexible connection
4 Roof Fan DVG EC Diagrams with dashed system curves Horizontal exhaust DVG-H EC 1 2 DVG-H EC/F DVG-H EC/F DVG-H 6EC/F DVG-H 6EC/F DVG-H 8EC/F
5 Roof Fan DVG EC Vertical exhaust DVG-V EC 1 2 DVG-V EC/F DVG-V EC/F DVG-V 6EC/F DVG-V 6EC/F DVG-V 8EC/F
6 6 Roof Fan DVG EC Examples of use Beside smoke and heat extraction, DVG EC can also be used for other ventilation purposes Intelligent control system can also control demand fan operation, based on external sensor demands (CO,, humidity, temperature,...). Industry, Car Park Systems Healthcare, Fitness, Gyms Shopping Malls, Showrooms, Kitchen exhaust CO % C
7 Roof Fan DVG EC 7 DVG EC connection example Fan electronics PC SCADA Modbus Monitoring DVG EC Roof socket Controller for CO level Max. kapacity in case of fire Daily ventilation IR-Fire detector Smoke detector Fire Smoke CO sensor GARAGE Fire alarm system
8 8 Roof Fan DVG EC Wiring diagrams WD1 (1~2V) Power supply - connection in service switch Control cables - connection in EC controller EC motor prewired WD2 (~V) Control cables - connection in EC controller EC motor prewired Power supply - connection in service switch Connection Functions Max. crossection of power supply wires: 2, mm 2 ( mm 2 without core end sleeves) Cable glands on service switch for power supply: 1xM2x1, Service switch ON-OFF, 6-pole + 1x NC Max. crossection of control wires: 1, mm 2 Cable glands of control part: 2x M2x1, F1 Fault relay F2 Analog input for set value / speed setting F Potentiometer for speed setting F External sensor F Speed output F6 FIRE mode (open = FIRE) F7 Start / Stop switch (open = stop) F8 Modbus connection
9 Roof Fan DVG EC 9 Electrical accessories - connection examples If the fan is supposed for fire ventilation too, switch to fire mode must be controlled by fire control system. Electrical accessories Accessories (sensors with output -1V) for daily ventilation, controlled by internal PI regulator (integrated in fan) Setup of internal PI regulator via Modbus. For use of internal PI regulator two analog signals (-1V) are needed. First one, which defines target (set point) value of regulated property (temperature, humidity, CO2,..) with analog signal connected to AN1 (connection 7 at 1~, 6 at ~) Second one, which defines actual measured value of regulated property (temperature, humidity, CO2,..) with analog signal from sensor, connected to AN2 (connection 11 at 1~, 8 at ~) Systemair-E-D, humidity, temperature sensor DSG 2,, 1 differential pressure sensor / humidity / temperature Systemair-E-D Item no. 19 % C Differential pressure transmitter with built-in PID cotroller 12 9 TEMP or RH% or CO2 1 TEMP, -1V/-2mA (Jumper) 2 COM/GND RH%, -1V/-2mA (Jumper) - PT CO2, -2mA 7 COM/GND CO2, -1V/- (Jumper) MTP 2 on/off, -step manual speed controller MTV-1/1 controller for manual speed control Differential pressure DSG 2 DSG Item no. 169 Item no. 17 DSG 1 Item no. 966 MTP 1 Potentiometer for manual speed control V Brown Output +...1V DC Yellow White + - S-EC/FRQ step switch for manual speed control Accessories with built-in PID controller V DC - IN 2V AC/DC Differential pressure transmitter with built-in controller with selectable range...1/ / / 1 Pa DMD-C Item no. 179 CO2RT-R-D sensor EC-Vent control board EC-Vent room unit
10 1 Roof Fan DVG EC Accessories for manual control of speed for daily ventilation step manual controller (2 speeds adjustable) MTP 2 Item no. 122 Controller for manual speed control MTV-1/1 Item no IN 2V + -1V DC Potentiometer for manual speed control MTP 1 Item no Us step switch with on/off function S-EC/FRQ Item no Us GND A Us = V DC Us = 1V DC Accessories for daily ventilation (switches ON-OFF) / Temperature - sensor with built-in relay CO2RT-R-D Item no. 699 C Common Normally open 1 Supply voltage 2 V AC 2 System neutral 2 V AC Normally closed
11 Roof Fan DVG EC 11 EC-Vent % % C C EC-Vent Room Unit Item no. 18 EC-Vent control board Item no. 11 ~ 1~ Regin CO2RT-D PT 1 PT 1 Signal neutral Out...1V DC CO2 Out...1V DC temperature Out...1V DC humidity System neutral Supply voltage 2V AC/DC The wiring of 1~ DVG EC and EC-Vent (the wiring of ~ DVG EC is analogue) The markings of EC-Vent as in instruction (A = power supply, RU = room unit, CB = computer board)
12 Systemair d.o.o. January 217 E81
Roof Fan DVG EC. Smoke extraction and daily ventilation in one!
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Roof Fan DVG EC Smoke extraction and daily ventilation in one! C/12min 12 C 2 Roof Fan DVG EC
More informationINTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation
JAU /JCC/JVC Series Jet Fans - for car park ventilation INTRODUCTION Pacific HVAC Engineering is able to offer a complete solution in car park ventilation at a competitive price with in house developed
More informationCONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE
CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS Compact heat recovery unit with high efficiency counter-flow heat exchanger in 5 sizes from 580 m3/h to 3.650 m3/h. The casing is made from aluminium profile
More informationWhen you think safety think Systemair
Smoke extract- and ATEX-fans When you think safety think Systemair www.systemair.com Smoke and heat extraction Certification test of axial fan HA, (above) and centrifugal roof fan DVV The smoke and heat
More informationThe Straight Way K Sileo Series
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans The Straight Way K Series Systemair Sdn Bhd certifies that the K fans shown herein are licensed
More informationDomestic & Commercial Fans
Max. airflow l/s Axial Fan Centrifugal Fan Speed Controllable Reversible Airflow Page Number BF IF CF CBF BF 64 * 16 IF 64 * 16 EAF LV 23 * 169 ECF LV 31 * 169 CF 25 * 170 CBF 31 * 170 RVF 0 * * 171 BRAVO
More informationKOMFORT EC DB Suspended heat recovery air handling units
2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.
More informationROOFMASTER STEF-HT ROOF FAN
fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT... 3 Performance Data... 4 Performance Table... 5 General description... 6 Fan Chart-explanation
More informationRS /E-EV C01 SERIES
The well-known RS 300-800/E-EV Burner Series, till now available up to 8 MW, has been upgraded with two new powerful burner models, the RS 1000-1200/E-EV models that extend his max output up to 12 MW and
More informationSmart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable
Smart Smart IR model (check applicable) is recognized as serviceable Service instruction SALES DATE MANUFACTURED ON (DATE): SOLD APPROVAL MARK SMART-EN-04 BLAUBERG Company is happy to offer your attention
More informationIonisation single-tube smoke detector for duct mounting
Detectors Ionisation single-tube smoke detector for duct mounting 600 mm venturi tube is included., incl. end resistor (not RAC(M)) 9...33 V DC (via ABV control unit). 24 V AC ±15 % for RAC(M) models.
More informationAir curtain.
Air curtain www.wingbyvts.com 01 VTS GROUP 1.1 VTS: Manufacturer No. 1 in the world 1.2 3 constituents of success 02 2.1 air curtains 2.2 Silence and power 2.3 Design and performance 2.4 Quality and design
More informationDVG. Installation and Operating Instructions for Anvisningar för montering och drift Инструкция по установке и эксплуатации. English Originalversion
DVG Installation and Operating Instructions for Anvisningar för montering och drift Инструкция по установке и эксплуатации DVG-H DVG-V English Originalversion DVG-H EC DVG-V EC General information Previous
More informationRS /E-EV C01 SERIES
The well-known RS 300-800/E-EV BLU Burner Series, till now available up to 8 MW, has been upgraded with two new powerful burner models, the RS 1000-1200/E-EV C01 models that extend his max output up to
More informationTECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK
GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T is characterized by having no additional moisture added
More informationKOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators
KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S Heat and Energy Recovery Ventilators 2018 AIR HANDLING UNITS 2 CONTENT KOMFORT EC S5B270(-E) 4 KOMFORT EC D5B1(-E) 8 KOMFORT EC S(B)(-E) 12 AIR HANDLING UNITS
More informationInstructions for the fan motor control system with integrated wiring terminals SILVER C
Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.
More informationSeries VENTS VUT R WH ЕС
AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS EH ЕС Series VENTS WH ЕС Air handling units with the air capacity up to 1500 m 3 /h in soundand heat-insulated casing with integrated electric heater.
More informationLOW NOx MODULATING GAS BURNERS
RS/E - RS/EV BLU SERIES LOW NOx MODULATING GAS BURNERS RS/E - RS/EV BLU SERIES RS 300/E BLU 500/1350 3800 kw RS 400/E BLU 800/1800 4500 kw RS 300/EV BLU 500/1350 3800 kw RS 400/EV BLU 800/1800 4500 kw
More informationInstructions for the fan motor control system, SILVER C
Instructions for the fan motor control system, SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units. The motor control system is
More informationKITCHEN EXTRACTORS CK Series Plastic range CK-60 F CK-40 F CK-25 N
KITCHEN EXTRACTORS CK Series Plastic range Centrifugal extractors manufactured from flame retardant plastic V. All extractors are class II insulation fitted with centrifugal impeller and single phase 23V-5Hz
More informationProduct Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S
D10 is a type-approved measuring device which combines the advantages of the measuring principles transmittance and scattered light forward. Therefore, it is ideal for measurement of very low to high dust
More informationK Series CK-25 N CK-35 N CK-40 F CK-50 CK-60 F ECO-500 KITCHEN EXTRACTORS. Kitchen extractors CK
KITCHEN EXTRACTORS K Series CK-25 N CK-35 N CK-6 F Range of centrifugal extractors specifically designed for the extraction of moist, grease laden air and fume from under domestic cooker canopies. This
More informationGLEC exhaust FAN. Air Comfort. Air movement. Duct & Box Fans
Air Comfort Air movement Duct & Box Fans GLEC exhaust FAN» Technical CATALOUGE Technical catalouge Exhaust Fan GLEC 2 Contents Exhaust fan - GLEC... 3 Performance Data...4 Fan chart-explanation and definitions...
More informationSPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module
SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:
More informationTECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK
GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T-TWIN is characterized by having no additional moisture
More informationTUNNEL FANS STANDARD AND HOT SMOKE
TUNNEL FANS STANDARD AND HOT SMOKE NovAx tunnel fans PRODUCT FACTS Product Novenco tunnel fans are produced with either round or rectangular outer dimensions. Both types are made in unidirectional (AUC
More informationAir handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses
REC Temovex 4S-EC-RS Experts on indoor climate in low-energy houses RT 4S-EC-RS REC Temovex 4S-EC-RS ECO2 control system for low-energy and passive houses Comprises: - Air flow boost for warm and cold
More informationSystemair product news - Fans NEWS
Systemair product news - Fans NEWS Perfect Climate. Anywhere. Anytime Smart, energy-saving solutions for ventilation and air-conditioning. Well-thought-out system solutions for every application area.
More informationMRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation
NUAIRE MVHR and Opposite Handed version ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due to its intelligent
More informationGB Art. Nr
GB150630 Art. Nr. 7020070 TheLumina 38H controls the climate in mechanically ventilated poultry houses using a heat exchanger. The Lumina 38H is a special version with full integration of the heat exchanger
More informationAPPLICATION DATA SHEET
APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors
More informationFans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL Wall mounted fan coil units SYSWALL Wall mounted fan coil units With a tangential
More information39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range
PRODUCT SELECTION DATA Plug & play unit (built-in control) Class A+ across entire range Classic/Vertical/ceiling-mounted dualflow units High-efficiency heat recovery unit High performance plug fan High-efficiency
More informationDräger Polytron 8000 Stationary gas detector (EC)
Dräger Polytron 8000 Stationary gas detector (EC) The microprocessor-based transmitter can be equipped with various electrochemical DrägerSensors. This way, you can easily detect oxygen and various toxic
More informationfor a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning
AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS enthalpy membrane in the warm season. This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the
More informationOPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11
OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES F88EN-02.indd 1 04.09.2015 8:07:11 2 VKM ЕС CONTENT Introduction Use Structural designation key Delivery set Main
More informationNitrogen Dioxide (NO2) Single-Point Gas Detection System
Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary
More informationLo-Carbon Sentinel Kinetic Horizontal
Lo-Carbon Sentinel Kinetic Horizontal MVHR Unit Features & Benefits Manufactured in the UK Building Regulations ADF compliant Recognised in SAP Appendix Q Energy Savings Trust best practice compliant Up
More information66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR
Central ventilation system ZLS Central ventilation system ZLS-DV EC according. ZLS-DV EC is the ideal central ventilation system in multi-storey construction according. EXTRACT AIR OUTSIDE AIR FIRE PROTECTION
More informationS F IT 6" / 8"HES. Quick Installation Guide. franklinwater.eu
GB D S F IT 6" / 8"HES Quick Installation Guide franklinwater.eu Summary Page English 5-19 Deutsch 25-39 Svenska 44-60 French 63-81 Italian 84-101 GB 6" / 8"HES Quick Installation Guide franklinwater.eu
More informationPHOTOELECTRIC AMPLIFIER SERIES
PHOTOELECTRIC AMPLIFIER SERIES Telco s photoelectric amplifier series performs as good today as it did when it first appeared almost 25 years ago. But while the simple design of this iconic product has
More informationProduct Data Sheet Adsorption Dryer DPS (A)
Version: 1.0.5 Author: Tassilo Tappe Date:13.07.2012 Field of application Adsorption dryers of the DPS series are designed for drying compressed air and nitrogen to pressure dew points of -25 C to -70
More informationRL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw
The RL/1 burners series covers a firing range from 107 to 398 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Optimisation
More informationHeat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min
Heat on Air heaters from 400 Watt to 17 400 Watt Blowers from 1,45 m 3 /min to 16,5 m 3 /min BAK Thermoplastic Need-to-know Calculation of air heaters 1. Heat requirement calculation Formula: Q = m * c
More informationFRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %
Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed
More informationDräger Polytron 8310 IR Detection of flammable gases and vapour
Dräger Polytron 8310 IR Detection of flammable gases and vapour The Dräger Polytron 8310 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit
More informationCUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams
Integrated chilled beams Key figures Connections: 1x mm, 2x mm Airflow: 5-60 l/s Pressure range: 40 - Pa Size: 293 x 200 mm (WxH) Length: 1192 or 1792 mm Total effect: up to 1200W Cumulus is available
More informationUSER S MANUAL AiR duct heater with integrated temperature control UNit or A control UNit
USER S MANUAL Air duct heater with integrated temperature control unit or a control unit 2 CONTENTS Safety requirements 3 Introduction 5 Use 5 Delivery set 5 Designation key 5 Main technical parameters
More informationHigh Efficiency Burner Controls Beyond Efficiency June 7, 2016
High Efficiency Burner Controls Beyond Efficiency June 7, 2016 GORDON SWANSON 1999 Present: Kidde-Fenwal, Ashland MA Since 2002: General Manager, Fenwal Controls, division of UTC Climate Control and Security
More informationMRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)
NUAIRE MVHR (including opposite handed versions) ACHIEVES 100% DUTY IN BYPASS MODE and MRXBOXAB- ECO-LP1-OH are specically designed for apartment applications where space is a premium. The new MRXBOX95-LP1
More information/8 DIN Level Indicator
Data Sheet SS/_6 High visibility 5-digit LED display clear and accurate indication Analog and relay outputs as standard high, low, latch and rate alarms, plus isolated retransmission Maths functions included
More informationMAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY
MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY Product Overview www.orcaenergy.eu MAXI Device for heat recovery MAXI is designed to provide permanent controlled air exchange by means of mechanical ventilation
More informationTopVent Design Handbook
TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit
More informationAnalog Annunciator Unit SACO 16 A3. Product Guide
Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Powerful, flexible and field-customizable 16-channel analog input signal annunciator unit A full
More informationUNIJET CAR PARK VENTILATION SYSTEM
Overview Discharge to Atmosphere UniJet is a packaged car park ventilation system designed to provide smoke clearance and pollution ventilation to covered car parks to comply with current building regulations
More informationFans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator Healthcare
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Facilitator Healthcare Systemair - Ventilation World Wide Systemair is a leading ventilation
More informationmore than just a fan supplier more than just a fan supplier Axair Fans UK Limited
1 more than just a fan supplier The most diverse range of industrial fans & accessories available from a single source... 2 products oem & industrial 3 single inlet centrifugal backward curved centrifugal
More informationFHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P
FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P 1 of 13 These instructions should be read by: The specifying engineer. The installation engineer. The user. The service engineer. WARNINGS Failure
More informationEnergy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)
c a i r c im M Si l g n e r m o o ai a h r r ving i a a ze h s gy s t si e Fr e r p a c En m Co a r th i y w r t s ov e i un rec g t n li ea d n h in t e til oun a rs m ise e V sy no Ea w Lo g Industrial
More informationTECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO
GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T-TWIN is characterized by having no additional moisture
More informationINSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS
INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS TSEK VENCO Havalandırma ve Makina San.ve Tic. A.Ş. 2004. Cad. No:5 45400 OSB Turgutlu MANISA / TURKİYE Tel: +90 (236) 332
More informationGas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2
Features Integrated (built-in NO2 sensor / detector (Electro chemical sensor type Measuring ranges 0-10 ppm, 0-20 ppm or 0-30 ppm LCD display to show actual in ppm Status LED indication Normal operation
More informationDanfoss gas detection units
Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning
More informationMaster devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems
X X testregistrierung Type Web server, also for mobile devices Zone modules Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X-AIRCONTROL zone
More informationHT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH
HT-1300 Series Temperature and Humidity Duct Sensor Product Bulletin Specifically designed for HVAC application, the HT-130x-UD1 sensor is a highly accurate and reliable for measuring relative air humidity
More informationADAPTER FOR VENTILATION DUCT BWP-143A-SS (STAINLESS STEEL)
ADAPTER FOR VENTILATION DUCT BWP-143A-SS (STAINLESS STEEL) Fire detection systems Product Datasheet Features Designed to detect smoke in ventilation ducts Reduces dust and other deposits on the detector
More informationInstructions OJ EC-Controller (Translation of the original) BA-ESR_OJ-EC /2013
Instructions OJ EC-Controller (Translation of the original) EN BA-ESR_OJ-EC 1.0 02/2013 Contents Contents... 2 1. Revision Index... 2 2. Introduction... 3 3. Features... 4 4. Installation... 4 5. Operation...
More informationDräger Polytron 7000 Fixed gas detector
DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger Polytron 7000 Fixed gas detector ST-3751-2003 The Dräger Polytron 7000 is a gas detector that can satisfy all toxic and
More informationAPPLICATION DATA SHEET
APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable
More informationELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems
Technical Bulletin BT13F002GB-04 ELFODuct MP New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems ELFODUCT MP 15-71 SERIES SERIES RECOMMENDED FOR
More informationSOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59
SOUND-INSULATED FAN OPERATION MANUAL _v.1(2)-en.indd 1 10.08.2015 15:20:59 CONTENT Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 3 Fan design 4 Delivery
More informationHorizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9
ERV/ HRV CONTENTS Horizontal rotor heat recovery ventilation unit RH 5 Vertical rotor heat recovery ventilation unit RV 9 Suspended plate heat recovery ventilation unit CFP Horizontal plate heat recovery
More informationP R O D U C T D ATA S H E E T
PGF- Effective Gas Safety Proving and Gas Detection Controller Gas Pressure Proving For use with Natural Gas LPG - or Laboratory gas supplies, both high and low pressure ensuring system integrity prior
More informationPRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit
PRODUCT INSTRUCTIONS Fire Door Control Panel (FDCP) Floats Rd, Wythenshawe, Manchester. M23 9WB T: 44 (0)161 945 4561 F: 44 (0)161 945 4566 Stock Code Description Doc No: PI115 00133 00134 Ellard Fire
More informationVENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС
HEAT RECOVERY AIR HANDLING UNITS Series VUT R TN H ЕС VUT R TN EH ЕС HEAT-RECOVERY VENTILATION Two-Stage Energy Saving System: HEATING COOLING Stage 1: Heat energy recovery by means of the rotary heat
More informationTopvex SF02-SF12 Air Handling Unit
Topvex SF02-SF12 Air Handling Unit Installation instructions Document in original language 130324 A004 GB Copyright Systemair AB All rights reserved E&OE Systemair AB reserves the rights to alter their
More informationRecalibrate the way you look at gas detection
Catalogue Gas detection solution Recalibrate the way you look at gas detection Next generation gas detection for industrial refrigeration The next generation of Danfoss gas detectors are based on a digital
More informationMRXBOXAB-ECO3 MRXBOX-ECO3
NUAIRE MVHR MRXBOX-ECO3 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due
More informationMRXBOXAB-ECO2 MRXBOX-ECO2
NUAIRE MVHR MRXBOX-ECO2 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due
More informationPioneer-R16 Gas Monitor Operator s Manual
Pioneer-R16 Gas Monitor Operator s Manual Edition 7/2/97 RKI INSTRUMENTS, INC RKI Instruments, Inc. 33248 Central Ave, Union City, CA 94587 (510) 441-5656 Chapter 1: Description About the Pioneer-R16 Gas
More informationCVE ECO 2 Range. System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible
CVE ECO 2 Range System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible CVE ECO 2 Applications The Itho extractor unit model CVE ECO 2 has been developed for use as a very quiet and
More informationINDUSTRIAL AIR CURTAIN. IndAC 2
INDUSTRIAL AIR CURTAIN IndAC IndAC industrial air curtain High climate separation efficiency with the IndAC industrial air curtain Optimal climate separation The Biddle IndAC industrial air curtain, is
More informationAXIAL FANS USER S MANUAL
AXIAL FANS USER S MANUAL WARNING! Disconnect the fan from power supply prior to any connection, servicing and repair operations. Only duly qualified electricians with valid electrical permit for electric
More informationInstructions for the BASIC BCRW Fan, Sizes General
Instructions for the BASIC BCRW Fan, Sizes 004 027 1. General The BCRW is a direct-driven fan of axi-centrifugal design. This fan offers excellent power efficiency, low, uniform air flow, low sound generation
More informationAxial fans The right fan for every house
Axial fans The right fan for every house Axial fans with frame for incorporation into walls Big Dutchman offers a wide range of axial fan types. This variety allows us to meet all the climate requirements
More informationIGD.CO.UK
APPLICATION DATA SHEET S p e c i f i c a t i o n 2 SO22 WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700+ D e t e c t o r Website: C o n t r o l P a n e l - Wall mounting or 19 Rack
More informationWD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.
Data Sheet Ref: 90501085 WD-CS Water leak detection cable Technical Overview The WD-CS range of cable sensors are typically used to detect water leaks usually under floors, and are used in conjunction
More informationPolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen
PolyGard Single Point Controller SPC-X3-XX for Toxic Gases and Oxygen DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor and
More informationTHERMASREG TR 040 THERMASREG TR 060
THERMASREG TR 040 THERMASREG Temperature controllers, one-step, Mechanical temperature controllers wet room temperature controllers THERMASREG TR 040 with switching output and stainless steel capillary
More informationgas monitoring system
www..com gas monitoring system Photon S is s most recent and most sophisticated apparatus. It was created based on portable gas analyser - Photon. As its sucessor it also uses gas sensors as the main measurement
More informationHeat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing
Field of application Description Advantages Range Technical details Installation Remote controls Servicing Remote control ErP * ** Conpliance compliance. ErP ready. Advantages Reversible connections. Ventilation
More informationConventional Fire Detection
SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct
More informationDräger Polytron 5200 CAT Detection of flammable gases and vapours
Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion
More informationPolyGard 2-channel Gas Controller MGC-03
PolyGard 2-channel Gas Controller MGC-03 DESCRIPTION Gas measuring and monitoring controller based on state-ofthe-art micro-technology with integrated buzzer for continuous monitoring of the ambient air
More informationP R O D U C T D ATA S H E E T
TOCSIN i700 SERIES Addressable & Analogue Gas Detection System Addressable technology from International Gas Detectors. Typical System is 40% Faster to Install with Fewer Connections Improved Reliability
More informationFresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.
Fresh air unit ALB ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. The ALB fresh air units from Helios provide comfortable room temperatures. Fresh outside air is
More informationIGH FX / IGH FX EC. Heat Recovery Ventilation Unit
Heat Recovery Ventilation Unit IGH FX / IGH FX EC has been designed to provide energy saving by recovery through heat energy exchangers. IGH FX / IGH FX EC is used in order to increase the quality of interior
More informationH3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog
H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...
More informationpanel filters with filtering class G4. Supply filter F7 can be supplied with the few models.
AIR HANDLING UNITS WITH HEAT RECOVERY Series Series VUT 350 PE EC VUT 600 PE EC VUT 1000 PE EC VUT 2000 PE EC VUT 3000 PE EC VUT 600 PW EC VUT 1000 PW EC VUT 2000 PW EC VUT 3000 PW EC Ceiling mounted air
More information