CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

Similar documents
>WIRELESS> ALARM SYSTEM CR200

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

Intelligent addressable fire alarm control panel

Evolution Product Range

Addressable and Conventional Fire Protection

System 800 Addressable Fire Detection & Alarm System

Intelligent Addressable Fire Alarm System

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

General Routing Interface

XC10 Extinguishing control panels

Installation, Operating and Maintenance Manual

Quick Selection Guide Analog Addressable Fire Systems

WIRELESS ALARM SYSTEM CR200 >SMART GPRS INTRUSION DETECTION PLUG & PLAY FUNCTIONS SELF-LEARNING, SMART FEATURES TEXT ZONE NAMING

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

Intrusion Outdoor Protection Perimeter

SALES SUPPORT DOCUMENT

Intelligent Single Loop Fire Alarm Control Panel

MINERVA MX. 800 Series Ancillary Equipment

CODESEC FIRE ALARM SYSTEMS. security technologies

Emergi-Lite Orbis detectors

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

Desigo Fire Safety intelligent detectors for complete safety

Fire Control Panel FS5100

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Specification/ Data Sheet

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

INPUT / OUTPUT MINI MODULES

Commercial and Light Industrial Fire Alarm Control Panel

Solution F2. Fire Alarm Control Panels one step ahead.

YOUR PARTNER IN FIRE & GAS DETECTION

EFBW series - BiWire Ultra control panel

FEC400 Series. Installation Manual

ACP10 & ACP50 Security Systems

NETWORK FIRE ALARM CONTROL PANEL. Features

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

Intelligent 2 & 4 Loop Fire Alarm Control Panels

The complete conventional fire warning system

XLH210: controller for gas leak detectors

Touch Screen 1 loop Addressable Fire Alarm Panel

Addressable Fire Alarm Control Panel

LF-4000 Series Conventional Fire Alarm Control Unit

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

LF /2. Fire Alarm Control Panel. Features:

Fire control panel detect 3004 plus and accessories

2013 Fire Alarm Systems Product catalogue

POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS

Quick Selection Guide Fire Systems LSN Periphery

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

CSP-204 CSP-208 CSP-104 CSP-108

-Industrial. W hen All Else Fails... Difficult Applications. The Only TRULY Industrial Air Sampling Detector For Hostile and Difficult Environments

OH110, OP110, HI110 Automatic fire detectors

Orion ISS. Intrusion and Fire Alarm Panel. Signal-10. User s Manual

DS7400Xi Addressable Control/ Communicator

Sita200plus. 200detectors. Single loop analogue addressable System

Passive infrared ceiling sensor

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

Honeywell Combination Fire & Burglary Control Panel

Honeywell Air Sampling Devices Data Sheet

FMR Installation Instructions. Addressable Fire System Controller

INTELLIGENT FIRE ALARM CONTROL PANEL

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

HART XL High Sensitivity Smoke Detection

Solution F1. Fire Control Panels the new generation

Evolution Analogue Addressable Fire System

Flexible Air-sampling Smoke Detection

intelligent solutions

Conventional Fire Alarm System 2014 V1.2

Excel-EN Conventional Fire Control Panel

Honeywell Air Sampling Devices Data Sheet

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

ZXSe Range Data Sheet

Cerberus FIT conventional system

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

2019 Fire Alarm Systems Product catalogue

ZSC100 Gas Detection and Alarm System Controller

Conventional Fire Alarm Systems. ACCLAIM SERIES 10 Conventional Fire Alarm System ACCLAIM SERIES 10.

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

Air Sampling Smoke Detection

User Manual. Dryer Controller M720

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

EXTINGUISHING CONTROL PANEL PX2 SERIES

ECO N DATE DESCRIPTION OF CHANGE CHG

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Fire Product Catalog

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

2017 Fire Alarm Systems Product catalogue

Desigo Fire Safety Marine Fire and Detection Equipment Models FH-2071-UM, BP-62 and USCG-HPLATE

Ethernet General Purpose

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

4 wire conventional alarm system

Intelligent Security & Fire Ltd

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Transcription:

FIRE DETECTION >FIRE DETECTION CONVENTIONAL C400 SYSTEM

FIRE DETECTION EFFICIENT AND MODULAR Elkron fire detection systems protect your business and grow with it Elkron's conventional fire detection range is flexible and complete and offers the best solutions for applications in the industrial and tertiary sector. Elkron fire detection systems are versatile and modular, ensuring full system scalability. The new C420 control unit can configure from 4 to 20 zones using optional ML420 modules. Main features of conventional control units: > Fully microprocessor controlled > Can configure from 2 to 20 zones > Non-volatile memory >P rogrammable alarm threshold >S imple, intuitive user interface >U p to 32 conventional detectors per zone >1 programmable relay output for each input The control units of the 400 Series are compatible with the entire range of Elkron conventional detectors. Finally, the intuitive user interface makes system programming and management simpler and quicker. > SHOPS > PUBLIC BUILDINGS > OFFICES > WAREHOUSES 2 CONVENTIONAL FIRE DETECTION SYSTEMS

SIMPLE, COMPLETE, VERSATILE The 400 Series conventional fire detection system by Elkron is easy to install and manage, thanks to its functionalities and wide range of accessories. Designed to meet the installation requirements of small- and medium-size systems in residential, industrial and office buildings. System events are stored on a non-volatile memory and visualised via simple icons. The system can be programmed using the buttons on the control unit front panel. The versatile systems of the 400 Series allow, for instance, to set a different alarm threshold for each zone (single and double/ multiple consensus), to FDO400 Smoke detector expand the system's capacity up to 20 zones and to have a programmable relay output for each control unit input. FDT400 Heat detector P440 Conventional push-button TM24 Optical/acoustic panel C404 Conventional control unit 4476/24 Bell 3

FIRE DETECTION 2 AND 4 ZONES: C402 AND C404 CONTROL UNITS Control unit with micro processor for 2/4 zones Fire detection control units C402 and C404 control up to two and four independent zones, respectively, with a maximum of 32 devices per zone. Each line is considered as a zone and can be either activated or deactivated via a command from keypad. The control unit has two outputs: one general alarm sounder output activated with at least one zone in alarm status, and one general malfunction output activated when a malfunction condition occurs either on control unit or in a zone. General alarm sounder output can be either activated or deactivated via keypad. Other relay, general alarm and zone alarm outputs are available on optional relay board. It is possible, for each single zone independently, to decide whether alarm notification is to be obtained with one alarmed device only (single consensus) or with at least two alarmed devices (double consensus). This allows to avoid false alarms. SPECIFICATIONS C402 item no. 80SC8000121 C404 item no. 80SC8400121 Number of zones 2 4 Certified EN54 part 2 and part 4 No. 0051-CPD-0338 No. 0051-CPD-0337 Power supply Pre-alarm absorption (single consensus): ma Alarm absorption (double consensus): ma Maximum current / Maximum external load Double threshold balanced lines Supervised sounder output Field output Malfunction relay output Material Electric output protection Non-volatile memory Battery charge control depending on environment temperature Battery charge cut System keypad Exclusion of single lines Zone warnings Batteries Operating temperature Dimensions 26.4 Vdc 20mA 40mA 1.9 A/1.6 A 24 Vdc @ 500 ma 24 Vdc @ 500 ma 24 Vdc @ 1 A ABS LED 2 x 7 A - 12 Vdc batteries -5 C +50 C 340(L) x 240(H) x 96(D) mm Accessories for conventional microprocessor control units Optional output module Optional modules MR402 (item no. 80SC5410121) and MR404 (item no. 80SC9810121) have 2 and 4 dry contact relay outputs, respectively, allowing to differentiate alarm notifications from each zone. > Relays in each zone are activated: - at transition to the alarm status of one single device (zone programmed to single consensus); - at transition to the alarm status of two or more devices (zone programmed to double consensus). > Optional modules MR402 and MR404 also feature one dry contact relay output signalling the alarm condition of any zone in the control unit. - Contact type: dry contact exchange. - Power supply: 26.4 Vdc. - Maximum current 1A with resistive load MR402 4 CONVENTIONAL FIRE DETECTION SYSTEMS

FROM 4 TO 20 ZONES: THE NEW C420 CONTROL UNIT C420 control unit item no. 80SC8600121 The new conventional control unit is modular and can control from 4 zones (standard configuration) up to 20 (with optional ML420 modules), to which it is possible to connect up to 512 devices. Each zone can manage up to 32 points or conventional devices, while the overall number of devices that can be managed by the control unit is 512. Each zone is associated to a relay that is activated when the zone enters an alarm condition. The control unit also features the following relay outputs: one alarm output, one sounder output, one malfunction output, one programmable output for activation in case of power failure or exclusions, one supervised sounder output. Four more supervised sounder outputs can be added with the optional module MR420. Each of these outputs can be associated independently to one or more zones. C420 The control unit features an alphanumeric 4x40 display and a 12-key keypad. It is also possible to connect a PS2 keypad for easier user input during the programming phase. The control unit features an event log that can store up to 1000 events. Main features > Compliant with EN54 standard part 2 and part 4. No. 0051-CDP-0382 > Number of lines: 4 expandable up to 20 > Number of zones: 4 expandable up to 20 >Power supply: 25.5 Vdc ± 5% under no load conditions > Maximum external load: 3 A > Alarm absorption (single consensus): 20 ma > Alarm absorption (double consensus): 40 ma > Supervised sounder output: 24 Vdc 500 ma > Field output: 24 Vdc 1A > Malfunction relay output: 30 Vdc 1A > Non-volatile memory: yes > Exclusion of single lines: yes > Info visualisation: 40x4 LCD display > Battery: 2 x 12 V 12 A > Material: ABS Cover - Painted metal base > Dimensions (W x H x D): 490 x 350 x 149 mm Accessories for C420 control unit ML420 item no. 80SC0910121: Extension module with 4 inputs/ 4 relay outputs > Contact type: NO/NC dry contact, selectable via jumper > Maximum applicable voltage 30 Vdc > Maximum current 1A with resistive load MR420 item no. 80SC0810121: Module with 4 supervised outputs > Output voltage 24 Vdc > 3300 Ω end-of-line resistor > Maximum output current 250 ma > Internal protection circuit - resettable ML420 5

FIRE DETECTION CONVENTIONAL SENSORS FDO400 item no. 80SD7U00121: Low-profile optical smoke detector Smoke detectors work according to the light scattering principle caused by smoke particles present in the air. The smoke detector features an automatic gain control function; a microcontroller calculates reading compensation to keep constant sensitivity and corrects any level increase due to dust depositing into the analysis cell. Smoke detectors should be installed in places protected against draughts which may divert the flow of combustion particles and in places where the activities usually performed do not cause the combustion of gases. FDT400 item no. 80SD8U00121: Low-profile heat detector Heat detectors control the temperature inside the area where they are installed. A micro controller analyses and compares the signal received from a precision heat detector of the NTC type, and activates the alarm if the temperature goes over 58 C. FDTD400 item no. 80SD1V00121: Low-profile differential heat detector Differential heat detectors control the temperature increase inside the area where they are installed. A micro controller analyses and compares the signal received from a precision heat detector of the NTC type, and activates the alarm if the temperature increases by over 5 C per minute. FDOT400 item no. 80SD9U00121: Low-profile optical heat detector Dual-technology detectors (smoke-heat) work according to the light scattering principle caused by smoke particles present in the air (TYNDALL effect) and on temperature monitoring within the area where they are installed. A micro controller analyses and compares the signal received from a precision heat detector of the NTC type, and activates the alarm if the temperature goes over 58 C. The smoke detector features an automatic gain control function; a microcontroller calculates reading compensation to keep constant sensitivity. FDO400 FDT400 FDTD400 SPECIFICATIONS FDO400 item no. 80SD7U00121 FDT400 item no. 80SD8U00121 FDTD400 item no. 80SD1V00121 FDOT400 item no. 80SD9U00121 Certified EN54 part 7 1293-CPD-0189 EN54 part 5 class A1S 1293-CPD-0179 EN54 part 5 class A1R 1293-CPD-0180 EN54 part 5 class A1 and part 7 1293-CPD-0178 Power supply 20 Vdc (modulated voltage from -15% to + 10%) Average absorption at rest 65 μa @ 20 Vdc 40 μa @ 20 Vdc 40 μa @ 20 Vdc 65 μa @ 20 Vdc Alarm absorption 23 ma @ 20 Vdc Minimum reset time 300 ms Operating temperature range -10 +55 C Max. relative humidity 93% Material ABS V0 Dimensions ø 90 x 31 (H) mm ø 90 x 40 (H) mm Weight 70 g 6 CONVENTIONAL FIRE DETECTION SYSTEMS

BASES FOR CONVENTIONAL SENSORS SD500 item no. 80SD4K00121: Standard base for 400 series conventional detectors SD500M item no. 80SD4S00121: Standard base for 400 series conventional detectors - 10 pcs SD500RL item no. 80SD1W00121: Standard base with relay output Through its output it is possible to control an outdoor visual repeater directly (with auxiliary power unit). Dry contact relay output: 1 A @ 30 V SD500 CONVENTIONAL PUSH BUTTONS P445 item no. 80SB3500121: Red glass-break alarm push-button. Conventional glass-break alarm push-button P440 P440 item no. 80SB3800121: Red manual reset alarm push-button. Conventional manual reset alarm push-button 2570WP item no. 80SB3100123: Red manual reset alarm push-button. Conventional manual reset alarm push-button for outdoor use, with reset key 2570WP SPECIFICATIONS P445 Item no. 80SB3500121 P440 Item no. 80SB3800121 2570WP item no. 80SB3100123 Actuation type breaking manual reset manual reset Certified EN54 part 11 1293-CPD-0169 EN54 part 11 1293-CPD-0168 EN54 part 11 Visual alarm repetition red LED Alarm absorption 20 ma @ 18 Vdc Max current 3A Dimensions 110 x 110 x 42 mm 110 x 110 x 42 mm 110 x 110 x 43 mm Degree of protection IP67 Operating temperature range -10 + 55 C -25 C + 70 C Relative humidity 93% +/- 2% non condensing Weight 100 g 110 g 7

E_ BR1012_FIRECONV_ENG comunico.info