1 Heating and Cooling Systems
2 Product Range
Product Range AQUAREA LT AQUAREA T-CAP : AQUAREA HT* 5 patents on T-Cap 3 patents on HT Ideal for new buildings and renovations Modulating operation Water outlet temperatures of up to 55 C For heating and sanitary hot water Ideal for new buildings and renovations Modulating operation Water outlet temperatures of up to 55 C For heating and sanitary hot water Constant heating capacity down to -15 C Ideal for heating system replacements Modulating operation Water outlet temperatures of up to 65 ºC For heating and sanitary hot water 3 * = Markteinführung Q1/2012
Product Range AQUAREA Pro Key Benefits No cascade installation up to 80 kw with GHP outdoor unit and 60 kw with ECOi No Glycol needed when WHE is located on the heated part of the building Full line-up of outdoor units which can conver up to 80 kw heat demand Large number of remote controls and interfaces 3.25 COP with water at 45 ºC and outdoor temperature of 7 ºC 4
Full Line-Up to Meet All Customer Requests From 3 to 70 kw for high connectivity, T-CAP, HT, Low capacity HP, High capacity HP On Mono-bloc and Bi-bloc systems Single-phase and Three-phase For heating and for cooling Connectable with Panasonic sanitary tank (200 l and 300 l) Connectable to solar panels 5
Aquarea-Wärmepumpe Aquarea Bi-Block Mono-Block Pro LT T-CAP HT LT T-CAP HT Pro Ecoi Pro Gas VRF Heating Heating and Cooling Heizen Heating Heating and Cooling Heizen Heating Heating and Cooling Heating Heating and Cooling Single Phase Three Phase Single Phase Three Phase Single Phase Three Phase Single Phase Three Phase Three Phase Three Phase 6 6
Product Range 4 2 2 2 SERIES DESIGNS MODES VOLTAGES LT HT BI-BLOC HEATING 230 V/1 Ph T-CAP Pro MONO-BLOC HEATING/COOLING 400 V/3 Ph < 11 CAPACITY LEVELS 3 kw 5 kw 6 kw 7 kw 9 kw 12 kw 14 kw 16 kw 20 kw 50 kw 71 kw MORE THAN 70 MODELS AVAILABLE 7
Aquarea HT 65 C New range HT ( High-Temp ) Water output temperature of 65 C down to -15 C ambient temperature Higher energy efficiency in low ambient temperatures No additional electric heating needed in many cases Ideal for renovations / heating system replacements Bi-Bloc Bloc and Mono-Bloc designs 230 V or 400 V Heating only 8
Sales Points Single refrigeration circuit for a substantially quieter indoor unit than dual circuit units used by competitors (Daikin, Dimplex) Evironmentally friendly refrigerant R407c Low operating pressures Excellent efficiency due to cutting-edge inverter technology and optimized heat exchangers COP values nearly as high as with T-CAP with water outlet temperatures of up to 55 C Can replace gas boiler heating systems in old buildings 9
Sales Points Water outlet temperature of 65 C down to -15 C ambient temperature No leak test required, because refrigerant charge is less than 3 kg Easy and fast installation Max. piping length 30 m; max. height difference 20 m Excellent price/performance ratio approx. 20 % cheaper than Daikin 10
HT Range Details BI-BLOC BLOC MODEL MONO-BLOC MODEL Power supply CAPACITY (A7-W35) WH-SHF09D3E5 WH-UH09DE5 9 kw 230 V / 1 ph / 50 Hz WH-SHF12D6E5 WH-UH12DE5 12 kw COP 4.55 4.40 Power supply CAPACITY (A7-W35) WH-SHF09D3E8 WH-UH09DE8 9 kw 400 V / 3 ph / 50 Hz WH-SHF12D9E8 WH-UH12DE8 12 kw COP 4.55 4.40 Power supply CAPACITY (A7-W35) WH-MHF09D3E5 9 kw 230 V / 1 ph / 50 Hz WH-MHF12D6E5 12 kw COP 4.55 4.40 Power supply CAPACITY (A7-W35) WH-MHF09D3E8 9 kw 400 V / 1 ph / 50 Hz WH-MHF12D6E8 12 kw COP 4.55 4.40 11
Low Capacity Heat Pump Range from 3/5 kw Single-phase Heating only Heating and cooling Max. output temperature of 55 C Operating range down to 20 C 12
Sales Points Ideal solution for low-energy or passive buildings Excellent COP Constant heating capacity even in very low ambient temperatures A-class hot water pump Low investment costs equal to gas condensing boiler, but substantially lower operating costs 13
Low Capacity Heat Pump Power Supply 230 V / 1 ph / 50 Hz CAPACITY (A7-W35) WH-SDF05E3E5A WH-UD05EE5 5 kw WH-SDF03E3E5 WH-UD03EE5 3 kw COP 4.5 4.62 14
Aquarea Pro ECOi Series TECHNICAL FOCUS Up to 56 kw on only 1 outdoor unit Produce hot water at 45 ºC with high efficiency Chilled water outlet temperatures from 5 ºC to 15 ºC Large line-up of remote controls from ECOi line-up High efficiency up to 20 ºC on heating mode High efficiency up to +5 ºC on cooling mode (chiller application) 15
Aquarea Pro ECOi Series DESCRIPTION No water heat exchanger for GHP and ECOi series Operation and control by wired Timer Remote Controller CZ-RTC2 Energy-efficient capacity control Stainless steel plate heat exchanger with anti-freeze protection control Change-over between heating and cooling operation Maximum distance between outdoor unit and water heat exchanger: 170 m Max. hot water outlet temperature: 45 ºC Min. chilled water outlet temperature: 7 ºC Outdoor temperature range in cooling mode: +5 ºC to +43 ºC Outdoor temperature range in heating mode: 20 ºC to +15 ºC 16
Aquarea Pro Gas VRF Eco G TECHNICAL FOCUS Up to 56 kw on only 1 outdoor unit Hot water outlet temperatures from 35 ºC to 55 ºC Chilled water outlet temperatures from 5 ºC to 15 ºC Large line-up of remote controls from ECOi line-up High efficiency up to 20 ºC on heating mode High efficiency up to +5 ºC on cooling mode (chiller application) 17
Aquarea Pro Gas VRF Eco G DESCRIPTION Hot water outlet temperatures from 35 ºC to 55 ºC Chilled water outlet temperatures from 5 ºC to 15 ºC Operation and control by wired Timer Remote Controller CZ-RTC2 Energy-efficient capacity control Stainless steel plate heat exchanger with anti-freeze protection control Change-over between heating and cooling operation Maximum distance between outdoor unit and water heat exchanger: 170 m Possibility to mix DX and water heat exchanger systems No cooling tower necessary Hot water outlet temperatures from 35 ºC to 55 ºC Chilled water outlet temperatures from 5 ºC to 15 ºC Outdoor temperature range in cooling mode: 10 ºC to +43 ºC Min. outdoor temperature in heating mode: 21 ºC 18
19 Remote Control Interface change
20 Tank
21 Aquarea Designer Version 1.6
Aquarea Designer Version 1.6 An additional diagram showing the energy coverage was added to the main page. 22
Aquarea Designer Version 1.6 All tariffs associated with the project can be viewed at a glance New Tariffs can be entered directly Existing tariffs can be changed directly 23
Aquarea Designer Version 1.6 All heat pump models can be selected now 24
Aquarea Designer Version 1.6 New software features Integration of 8 new models New category Normal / High temperature when selecting a heat pump Special Polish and Turkish version (with English as PAD language) Default tariffs (from dat file sent) for these versions: Eng, Fra, Tur, Pol, Ger Default investment costs for these versions: Eng, Fra, Pol, Ger New licence text for French version 2 products deleted: WH-SDH09C0E8, WH-SDH12C0E8 French manual in installation Partly-parallel modes of operation deleted New "!" button in main window (left of heat pump button): active only when heat pump is not able to provide necessary flow temperature 25
26 THANK YOU VERY MUCH