Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool

Similar documents
HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

Beamex. Calibration White Paper. Calibration in hazardous areas

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Beamex Calibration White Paper. Calibration in hazardous areas

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

Explosion protection Marijan Gorše, dipl. ing.

Overview of Hazardous Locations as They Relate to Solenoid Valves

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

[ TECHNOLOGY ] and does this definition affect a burner.

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Explosion-protected actuator Page 259 of 292

WHAT WHITE PAPER IS POTENTIALLY EXPLOSIVE ATMOSPHERE CERTIFICATION AND WHY YOU. June 2010

Electrical Area Classification 101 An Introduction to Area Classification the Basics IEEE Houston CED

ATEX Safety Switches. More than safety.

1. GENERAL TECHNICAL INFORMATION

ATEX, NOMENCLATURE AND CODING

UL HAZARDOUS LOCATIONS SERVICES

VSD AND SS DRIVING ATEX MOTORS February 2014

PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-8: ELECTRICAL EQUIPMENT ENCLOSURES AND HAZARDOUS LOCATIONS

Guide for hazardous areas

Introduction to Hazardous Electrical Location Classifications

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

Explosion-proof Duct Heaters

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

S T R I T T & P R I E B E I N C.

CLASS I LOCATIONS ZONE CLASSIFICATION

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas

FUEL. Fire & Flammable Liquids Properties. Flammable & Combustible Liquid Safety. Safety. Practice. Laws: OSHA & NFPA. Safety.

Understanding Hazardous Locations Concepts

ATEX, NOMENCLATURE AND CODING

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

August Process Industry Practices Electrical. PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification

MICROpeL 75 Combustible Gas Sensor Part Number: PM

Electrical Installations Design, Selection, Erection and Inspection

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

Articles , & National Electrical Code Review & Application Guide

A Guide to Safe Electronic Weighing in Hazardous Locations

Area Classification and Types of Protection for Explosive Atmospheres: A Review

Intrinsically safe acoustic emission equipment opens the door to permanent monitoring applications in the oil and gas industry

Fire Alarm System Accessories

Implementation of ATEX Guidelines

Relays for use in hazardous locations. Class I, Division 2 and ATEX

Specifying Temperature Sensors for Hazardous Areas

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

SELECTION, INSTALLATION & TESTING OF ELECTRICAL EQUIPMENTS IN HAZARDOUS AREA

IRceL CH4 Methane (CH 4

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

ESSENTIAL EXPLOSION PROTECTION

Hazardous area descriptions

Process Instrumentation. Product Guide. Registered Quality System to ISO 9001

Manual. WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-xxx Definition of Terms, Marking and Installation Regulations. Version 1.0.

Fire Alarm System Accessories

Oil & Gas Oil & Gas. Control Control. every move. Directional Control Valves & Regulators Pressure Controls Temperature Switches Level Controls

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE

Guide to Hazardous Location Approvals:

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres

IECEx Certificate of Conformity

Dual certification! Air handling units for potentially explosive atmospheres

Hazardous Area Classifications and Protections

Approval of Ex (Electrical) Equipment for use/installation in Hazardous Areas.

NCS/SAS IAS/PES Chapter Seminar January 25-27, Hazardous Locations. OBIEC Consulting George Morlidge Fluor Canada

Fluke 568 Ex Intrinsically Safe Infrared Thermometer

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations)

ESD500. ESD500 Combustible / Toxic Gas Detector

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Intrinsically Safe Solutions

Explosion-protected network cameras Safety first

TECHNICAL SOLUTIONS APPLICABLE TO ELECTRICAL EQUIPMENTS DESIGNED FOR USE IN EXPLOSIVE GAS ATMOSPHERES

ESD3000 ESD200 Combustible / Toxic Gas Detector

Electron Microscopy Sciences

Explosion-proof Immersion Heater Type D-8660

DuPont Formacel Z-2. Safety and Handling of DuPont Formacel Z-2: Thermoplastic* Foam Extrusion Applications FOAM EXPANSION AGENT TECHNICAL INFORMATION

Meeting the Requirements of NFPA 820:

ATEX Vacuum Pumps in Accordance with the Directive 94/9/EG (ATEX 95) Technical Information

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

NJSP HMRU. Module 5 B HM Operations 1

Explosive. Atmospheres. Safety and Reliability

White Paper: Hazardous area classification in a nutshell and overview of Arista Industrial computers

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY

Page 1 Copyright by the Fieldbus Foundation All rights reserved.

Technical Information

Guide to Explosion Protection and Plant Safety

ESSENTIAL EXPLOSION PROTECTION

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

SAFETY APPROVED FLASHLIGHTS: UNDERSTANDING THE REQUIREMENTS INTRODUCTION & OVERVIEW

FLAMMABLE GAS DETECTOR DAX 3F-C INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FC_MAN01_EN.indd Ver. V1R2

PRIMATECH WHITE PAPER PROCEDURE FOR DUST HAZARD ANALYSIS (DHA)

Transcription:

Hazardous Area Classification in Oil & Gas Industry A Fire Prevention Tool SFPE ENGINEERING TECHNOLOGY CONFERENCE Oct 4, 2010 New Orleans, LA 1

Overview Oil and gas plants handle flammable materials 2

Flammable Range 100% Too lean to burn Air Flammable Too rich to burn 0% LFL UFL LFL UFL Lower Flammable Limit Upper Flammable Limit 3

Flammable Range of Few Materials Material LFL (Vol %) UFL (Vol %) Methane 5 15 Ethane 3 15.5 Propane 2 9.5 Butane 1.5 8.5 Hydrogen 4 75.6 4

Flammable Range - Methane 100% Too rich will not burn UFL 15% LFL 5% 0% Flammable Lean will not burn 5

Source of Release A point from which a flammable gas, vapor or liquid may be released into atmosphere. ex. flanges, instrument connections, pump seals, etc 6

Sources of Release Flange Instrument Connection 7

Fire Triangle Simultaneous occurrence of all three sources causes fire. Cutting off any one, extinguishes fire. 8

Ignition Source Electrical Apparatus 9

Aim of Area Classification To avoid ignition of releases that may occur from time to time The approach is to reduce to an acceptable level the probability of coincidence of a flammable atmosphere and an electrical or other source of ignition. 10

Hazardous Area A three dimensional space in which a flammable atmosphere may be expected to be present at such frequencies as to require special precaution for the design and construction of equipment, and the control of potential ignition sources. Leak Source 11

Hazardous Area Hazardous Area 12

Extent of Hazardous Area Direct Example Approach limited to common facilities Point Source Approach release rates are dependent on process conditions Risk-based Approach an option methodology which may reduce the hazardous area determined by the point source approach 13

Grade of Release Continuous: A release that is continuous or nearly so. Primary: A release that is likely to occur periodically or occasionally in normal operation. (Vents, Sample points, etc) Secondary: A release that is unlikely to occur in normal operation and, in any event, will do so only infrequently and for short periods. (Flanges, Instrument connections, etc) 14

Subdivision of Hazardous Area Zone 0: flammable atmosphere is continuously present or present for long periods. Zone 1: flammable atmosphere is likely to occur in normal operation. Zone 2: flammable atmosphere is not likely to occur in normal operation and, if it occurs, will exist only for short period. 15

Zone and Division Continuous Release Primary Release Secondary Release Zone 0 Zone 1 Zone 2 Division 1 Division 2 Codes and Standards IEC 60079, IP 15, API 505, NFPA 497 API 500, NEC Article 500, NFPA 497 16

Grade of Release and Zone (Division) Under unrestricted open air conditions: Continuous grade normally leads to Zone 0 (Division 1) Primary grade normally leads to Zone 1 (Division 1) Secondary grade normally leads to Zone 2 (Division 2) 17

Effect of Ventilation The term grade of release and zone are not synonymous. Poor ventilation may result in a more stringent zone while, with high ventilation provision, the converse will be true. 18

Zone Classification Cone Roof Storage Tank Zone 1 Zone 0 Zone 1 Zone 2 19

Zone Classification Floating Roof Storage Tank Zone 1 Zone 1 Zone 2 20

Classification of Zone (Division) Zone (Division) classification is based on the frequency of release. Each zone (division) is further classified into Groups and Temperature Class based on the properties of flammable material processed in that zone (division). 21

Gas Group Flammable materials are sub-divided into groups based on minimum ignition energy required for igniting them. Typical Gas Hazard NEC Article 500 IEC Acetylene A IIC Hydrogen B IIC Ethylene C IIB Propane D IIA 22

Auto-ignition Temperature (AIT) Minimum temperature required to initiate or cause self-sustained combustion of the fluid independent of the heating. 23

Temperature Class Temperature Class is assigned to flammable material based on its autoignition temperature. Temperature Class Auto-ignition Temperature ( o C) T1 >450 T2 >300 T3 >200 T4 >135 T5 >100 T6 >85 24

Auto-ignition Temperature (AIT) Material AIT ( o C) Temperature Class Methane 595 T1 Ethane 515 T1 Propane 470 T1 Butane 365 T2 Pentane 285 T3 25

Area Classification Zone 2 IIC T1 Zone 1 IIA T3 Zone 2 IIA T3 Zone 1 IIC T1 26

Battery Room Lead acid batteries emit H 2 during charging and create hazardous area Battery rooms are classified as Zone 1 Group IIC Temperature Class T1 27

Selection of Electrical Equipment Factors to be considered: Zone in which the equipment will be used. Sensitivity to ignition of the material likely to be present, expressed as a gas group. Sensitivity of the material present to ignition by hot surfaces, expressed as a temperature class. 28

Selection According to Zone Classification Equipment suitable for Zone 0 can be used in Zones 0, 1 or 2. Equipment suitable for Zone 1 can be used in Zones 1 or 2. Equipment suitable for Zone 2 can be used only in Zone 2. 29

Selection According to Gas Groups Grouping becomes more severe in going from IIA to IIB to IIC. Group IIB equipment may be used in place of Group IIA equipment. Group IIC equipment can be used in place of equipment for both Group IIA and IIB. 30

Selection According to Temperature Class Temperature Class Maximum Surface Temperature ( o C) T1 450 T2 300 T3 200 T4 135 T5 100 T6 85 Equipment having a lower maximum surface temperature class may be used in place of that a higher maximum surface temperature (lower T class), but not conversely. 31

Equipment Protection Oil Immersed Protection Heavy current switchgear and transformers Pressurization or Continuous Dilution Analyzers, control boxes, etc Powder-filled Protection Electronics, chokes, etc Flame-proof Enclosure Motors, lighting, junction boxes, etc 32

Summary Identify the flammable materials. Identify sources of release and determine grade of release (and hence Zone 0,1, 2 or Division 1, 2). Determine extent of hazardous area. Assign Gas Groups and Temperature Class. Select appropriate Electrical apparatus. 33

34 Thank you