WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations.

Similar documents
Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations

Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations. Description. Installation WARNING

Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

standards: standards:

INSTRUCTION & SERVICE MANUAL

Applications. Standard Materials

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

Installation Instructions for W2H Series Signals

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

INSTRUCTION & SERVICE MANUAL

Installation and Maintenance Manual. Model 154XST Series Strobe Light for Use in Hazardous Conditions. français...page 21 español...

N2MVF Series Compact Fluorescent

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

SELECT-A-HORN/STROBE SERIES

LMV Series W Low Profile - Medium Base

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Enclosure 4X

Homeland Security Light

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

EVLPF Series Compact Fluorescent

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

CSH24CH. Colored Light Strobe/Horn Series High Candela. Description. Features. Ceiling/Wall Mount Patent Pending. Ordering Information

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

MODELS ASHP, ASHH, ASUP, and ASUH

MODELS 304GC, 304GCX, 314GC, and 314GCX

Explosion Proof Emergency Fluorescent Light Combination - Dimmable Ballast - C1D1-2 T8 lamps - 4'

L-Series, Indoor Strobes and Horn Strobes

LTFX Electric Tank Immersion Heaters Installation Instructions

AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER IMPORTANT SAFETY INSTRUCTIONS

EVLED201 36W Led Luminaire. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 14.85

CXH-A Forced-Air Heater

The Signal Is Clear TM

Chromalox. Installation, Operation. Screw Plug Heating Solution Control Panel Assembly for Screw Plug Heaters RENEWAL PARTS IDENTIFICATION

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

L-Series, Emergency Communication Devices

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

Installation and Operation Manual For Hunter Ceiling Fans /16/2004

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

elevated ambient capability. in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems.

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

Owner s Guide and Installation Manual

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

Hazardous Area LED Light -Class 1 Div 2 Groups A, B, C, D and Class 2 Div 2 F,G - 4' 4 lamp

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2

Table of Contents What to Expect with. Mounting Options. Tools Needed. Downrod. Blades

DMV Series W For Combustible Dusts

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

STI-1229-HAZ STI-1229HTR-HAZ STI-1229HTR240-HAZ

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

INSTRUCTION MANUAL (ATEX / IECEx)

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Flex-Tone Explosionproof Electronic Signals ETH655 & ETH855 SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. Installation

RELEASE DEVICE CONTROLS

CircoloTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

PRO Series Energy Star Ceiling Fan Owner's Manual

60" Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

Ex Mark:Ex d eb ⅡB T6 Gb

L-Series, Indoor Strobes and Horn Strobes

s Notification Appliances

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

EEMAX SERIES-TWO WATER HEATERS

ELECTRIC UNIT HEATER UH SERIES

CEILING FAN OWNER'S MANUAL

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

X Series (Model B) Explosion Proof Heater

Signature Series Auto-Sync Output Module (CC1S)

Explosion Proof 160 W Class 1 & 2 Fluorescent UV Light With 4 Lamps - Class 1 Division 1

Mounting Kits. LWMB2 6" 6 3 /8" 5 7 /8" 2.6 lbs lbs. LCMB2 6" 5" 5 3 /4 2.3 lbs. 2.5 lbs.

MODELS SafeSite LED Linear, Class I Div. 1 2 & 4 Versions

TYPE C: RETURN AIR UNDER POSITIVE PRESSURE FROM SEPARATE BLOWER

Static Pressure Alarm For Hazardous Location Fume Hoods

CEILING FAN OWNER'S MANUAL

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

TrueAlert Multi-Candela Notification Appliances

*RENTAL* Class 1 Division Watt Incandescent Light - Explosion Proof - Wall Mount Volts

KimberleyTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

SuperKlean Washdown Products

VAPORGARD Incandescent Luminaires

TECHNICAL DATA OBSOLETE

2 Installation Instructions For Vari-Fan Ceiling Fans Installation Instructions For Vari-Fan Ceiling Fans 11

Certificate of Compliance

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

Transcription:

Cheshire, CT 064 3-699-30 (Ph) 3-699-3365 (Cust. Serv. Fax) 3-699-78 (Tech. Serv. Fax) Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations STANCHION 116EX-S 1 1/ HUB CEILING 116EX-C 3/ HUB PENDANT 116EX-P 3/ HUB 116EX-C WALL 116EX-B 3/ HUB 116 SERIES HOUSING AND GLOBE ASSEMBLY WITH GUARD Figure 1. Mounting Options Description The 116DEXSTC-FJ AdaptaBeacon is an in-rush current limited strobe light. When pendant, wall or ceiling mounted, it is UL1971 Listed Signaling Appliance for the Hearing Impaired. Stanchion mount models are UL 1638 Listed for Private Mode Emergency Signaling. All models are CSFM Listed. The strobe is intended for indoor use in UL listed compatiable fire alarm systems and other applications requiring electrical supervision of signaling circuit field wiring. This strobe flashes a 3-degree beam of light approximately 65 times per minute with a UL 1971 cd wall and ceiling light output per Figure 7. When assembled in accordance with these instructions, the 116DEXSTC-FJ visual strobe signal is UL Listed for use in Class I, Division 1, Groups C and D, Class I, Division 2, Groups A, B, C and D, Class II Division 1, Group E, F and G, Class II, Division 2, Group F and G, and Class III Division 1 and 2 hazardous locations with Operating Temperature Codes per the following chart. See Table 1 for Electrical Specifications. This strobe is UL and cul Listed as a Type 3R and 4X enclosure. See Figure 1. Installation Install this unit in accordance with the applicable requirements in the latest edition of the National Fire Alarm Code (NFPA 72), National Electrical Code (NFPA ), and Canadian Electrical Code. WARNING To reduce the risks of ignition of hazardous atmospheres and shock, do not apply power to the unit until installation has been completed and unit is tightly assembled and secured. 1. Mount using the following applicable method. a. Pendant Mount Models (Figure 2): Install the catalog number 116EX-P, pendant mounting module, to the main housing. Install explosionproof hanger box (not supplied). Secure 3/ (19 mm) NPT threaded conduit (not supplied) to the box. Install the unit on the conduit. Proceed to step 2. b. Ceiling Mount Models (Figure 3): Mount the catalog number 116EX-C, ceiling/wall mounting module, using appropriate hardware (not supplied) suitable for the mounting surface. Proceed to step 2. c. Bracket Mount Models (Figure 4): Install the catalog number 116EX-C ceiling/wall mouting module using appropriate hardware (not supplied) for the mounting surface. Install the catalog number 116EX-B wall mounting elbow to the wall box. Run the unit's wiring through the elbow to the wall box. Proceed to step 2. d. Stanchion Mount Models (Figure 5): Install the catalog number 116EX-S, stanchion mounting module, to the main housing. Run the unit's wires through the 1 1/ conduit to the appropriate junction box. Install the unit on the conduit. Proceed to step 2. 2. Connect field earth ground wire to ground screw or earth ground via conduit system. 3. Wire the unit in accordance with Figure 6. See Table 3 for required supply wire temperature ratings. 4. As appropriate, install the fixture on the mounting module. WARNING To reduce the risk of ignition of hazardous atmospheres and shock, keep assembly tightly closed when circuits are energized. 5. Apply power to the unit and ensure proper function. P/N 30759 ISSUE 1 04

6 3/ 12" 12 3/ 5/16" 1" 13" 13 3/ 7 1/ 7 1/ Figure 2. Detail of Pendant Mounting Figure 3. Detail of Ceiling Mounting 13 1/ 12 9/16" 9 7/16" 6 3/ 1" 1/ 16 1/16" 5/16" 12 3/ 13 1/2" 16 13/16" 1 1/ Conduit Figure 4. Detail of Wall Bracket Mounting NOTE: Not for use as a Public Mode Fire Alarm Signal Figure 5. Detail of Stanchion Mounting NOTE: DC polarity of circuit shown in supervisory state (signal inactive). Circuit polarity to reverse to activate signal. Electrical supervision requires wire run to be broken at each device. Device for constant input voltage. Do not connect to coded or pulsating voltage. KEY: Light symbol - From Power Source or Previous Signaling Device Series 116DEX Series 116DEX Wire nut symbol - End-of-Line Resistor, when required with supervised system NOTE: For non-fire alarm use, i.e. without field wire supervision, installer can tie the two white leads together and tie the two black leads together. Figure 6. Wiring Diagram P/N 30759 ISSUE 1

Maintenance Disassemble the unit as follows (Figure 8): WARNING To reduce the risk of ignition of hazardous atmospheres and shock, keep assembly tightly closed when circuits are energized. To reduce the risk of ignition of hazardous atmospheres and shock, disconnect from the supply and circuit and allow five (5) minutes for stored energy to dissipate before disassembling the unit. 2. Loosen the globe and ring assembly set screw. Insert a suitable tool into the notches in the globe and ring assembly and loosen the assembly by prying in a counterclockwise direction. Remove the ring and globe assembly. 3. Refer to Table 2 for the correct replacement catalog number and replace the necessary part. 4. To replace, simply screw the unit on until it seats firmly onto its gasket. Tighten the unit another 1/8 to 1/4 turn. Tighten the setscrew. 5. Reinstall the guard, where applicable, and secure using the three supplied screws. 6. After the unit is assembled, apply power and make sure the unit functions properly. 1. Loosen the (3) guard screws and remove the guard. Table 1. 116DEXSTC-FJ AdaptaBeacon Strobe Light Electrical Specifications Max RMS Operating Voltage Designation* Current (A)** Regulated 24V DC 0.2 Regulated 24V FWR 1.1 CAUTION: To prevent damage to the signal circuit and to otherwise assure continued proper functioning, DO NOT operate the unit outside of the Regulated 24V DC/FWR voltage range of 16-33V DC/V FWR. *The designation Regulated 24 refers to the voltage range of 16-33 volts. **The Max RMS Operating Current is defined as the current rating over the entire voltage range. Table 2. 116DEXSTC-FJ Catalog Electrical Conduit Flash Strobe Tube Description Number Ratings Size Rate Replacement Housing Less 116DEXSTC-FJ 16-33V DC N/A Approx. 92-ST Mounting Module 0.2/1.4A 65 fpm Ceiling/Wall 116EX-C N/A 3/ NPT N/A N/A Mounting Module Pendant 116EX-P N/A 3/ NPT N/A N/A Mounting Module Stanchion 116EX-S N/A 1 1/ NPT N/A N/A Mounting Module Wall Bracket 116EX-W N/A N/A N/A N/A Mounting Elbow Table 3. Ratings Operating Temperature Ambient Supply Wire Class I, Div. 2 Class I, Div. 1 & 2 Class II & III, Div. 1 Class II & III, Div. 2 Temp. Temp. Marking Groups A, B Groups C, D Groups E, F, G Group F, G C 75 C T2D (215 C) T6 (85 C) T4A (1 C) T4A (1 C) 55 C 90 C T2C (2 C) T6 (85 C) T4 (135 C) T4 (135 C) P/N 30759 ISSUE 1

WALL BRACKET MOUNTING UL1971 REQUIRED DISPERSION AS % OF CD RATING ANGLE (DEGREES) VERTICAL PLANE HORIZONTAL PLANE zero 0% 0% 5 90% 90% 90% 90% 15 90% 90% 90% 90% 25 90% 90% 90% 75% 35 65% 75% 46% 75% 34% 75% 27% 55% 55 22% % 18% % 65 16% 35% 15% 35% 75 13% % 12% % 85 12% 25% 90 12% 25% Compound 24% Effective Candela Light Output for Wall Bracket Mount Vertical Plane (Zero degree angle at side of globe) TYPICAL CD UL REQUIRED CD FOR 35 RATING -90 1 1 1 0 90 0-85 - -75 - -65 - -55 - - - -35 - -25 - -15 - -5 0 degrees 5 15 25 35 55 65 75 85 UL 1971 Hearing Impaired: cd wall CEILING MOUNTING UL1971 REQUIRED X & Y PLANE DISPERSION AS % OF CD RATING ANGLE (DEGREES) 0 0% 5 90% 90% 15 90% 90% 25 90% 75% 35 75% 75% 75% 55% 55 % % 65 35% 35% 75 % % 85 25% 90 25% Compound 24% 75 85 90 95 0 5 1 115 Effective Candela Light Output for Ceiling Mount X & Y Planes (Zero degree angle at bottom of of globe) 1 125 1 135 1 1 1 1 0 90 0 1 175 1 165 1 155 1 degrees 0 15 5 5 15 25 25 1 1 135 1 125 1 115 1 5 0 95 90 85 75 35 35 55 55 65 65 1 1 1 155 1 165 1 TYPICAL CD UL REQUIRED CD FOR 55 RATING UL 1971 Hearing Impaired: cd ceiling P/N 30759 ISSUE 1 Figure 7. Light Output Patterns for 116DEXSTC-FJ

Strobe Tube Globe & Ring Assembly Guard CAUTION: Wait 5 minutes for strobe energy to dissipate prior to disassembly. Figure 8. Disassembly of the 116DEXSTC-FJ AdaptaBeacon P/N 30759 ISSUE 1

Contacting Edwards: Phone: (3) 699-30 E-Mail: techsupport@edwards-signals.com customerservice@edwards-signals.com Website: http://www.edwards-signals.com P/N 30759 ISSUE 1