ROOF ICE MELT (RIM) SYSTEM

Similar documents
ROOF ICE MELT (RIM2) SYSTEM

EN RaychemRIM2StandardInstallationManual IM H /16 1

Roof and Gutter De-Icing

SAFETY & COMFORT FOR THE HOME RESIDENTIAL MARKET U.S. PLUMBING CANADA PLUMBING AND ELECTRICAL

COMMERCIAL & RESIDENTIAL MARKETS U.S. ELECTRICAL

COMMERCIAL & RESIDENTIAL SELF-REGULATING HEATING PRODUCTS APPLICATION AND DESIGN GUIDE EUROPE, MIDDLE EAST, AFRICA

ROOF AND GUTTER DE-ICING ICESTOP SYSTEM

FTC-HST WARNING: CAUTION:

THERMAL MANAGEMENT SOLUTIONS

XL-Trace System Application and Design Guide

IceStop System Installation and Operation Manual

IceStop System INSTALLATION AND OPERATION MANUAL FOR ROOF AND GUTTER DE-ICING SYSTEMS

Commercial and Residential Self-Regulating Heating Products

SMPG3 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL. For three-phase heating cables PRODUCT OVERVIEW

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System

COMMERCIAL HEAT TRACING PRODUCTS AND SERVICES

Freezer Frost Heave Prevention

FreezGard. Self-regulating crankcase heater. Product Overview

RayClic Connection System

Gardian W51. Approvals

DISTRIBUTOR GUIDE FOR SELLING QUALITY TO CONTRACTORS

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

COMMERCIAL HEAT TRACING PRODUCTS AND SERVICES. thermal ManaGeMent.

The IceFree Eave System

HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

HotValley TM

HWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

JBS-100-EC Electronic controller replacement kit for JBS-100-ECP-A and JBS-100-ECW-A Installation Instructions

THERMAL MANAGEMENT SOLUTIONS

COMMERCIAL HEAT TRACING. Products and Services

SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES PRODUCT OVERVIEW

Design Guide Design Notes Design Examples Technical Data Sheets Expanded Capabilities Specifications Warranty

INSTALLATIONGUIDE. HotSeam TM Overview ICE ROOF

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

Radiant Edge LT TM Ice Melt System Installation and Operation Guide Version 1.4

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated)

FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM

Principle of Operation:

Edge Melt Systems. Roof Ice Prevention Perfected Product Catalog. PO Box Delafield WI Version 2.

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

Longline Heating. Contents. Introduction

Operating Guidelines for Your Roof and Gutter Ice Dam Prevention System

Self-regulating Roof Heat Cable

Toll Free:

Fire Sprinkler Freeze Protection Design / Install Guide

CSI Master Format 2012 Guide Specification for: Hot Water Temperature Maintenance (HWAT) Systems

C A Heating Cable Gland Kit

HotEdge Rail TM

Skin-Effect Heat-Tracing System (STS)

ADVANCED INDUSTRIAL SOLUTIONS HEAT-TRACING PRODUCTS & SERVICES

HHS-WWH HOPPER HEATING SYSTEM WRAP-WOUND HEATER INSTALLATION INSTRUCTIONS DESCRIPTION. HHS-WWH PRODUCT SPECIfICATIONS

Technology for human beings that is, compatible with nature, creating permanent HEAT TRACING Dreams that can greatly improve the quality of life,

SECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES

Factory and Field Installed Splices

HotEdge Rail TM

INDUSTRIAL HEAT TRACING SOLUTIONS PRODUCTS & SERVICES

Self-regulating Roof Heat and Gutter Trace Cable

Frost Heave Protection System Installation and Operation Manual

The Technology Leader. Deicing Systems Catalog PO Box Delafield, WI

For Raychem ACS-30 Controls Systems

The Roof Ice Prevention Leader. Deicing Systems Catalog PO Box Delafield, WI

RX1200 ROOF AND GUTTER DE-ICING CONTROLLER INSTALLATION AND OPERATION MANUAL

ACS-30-EU-VIA-DU-20-MOD

sulfur transport pipelines Safe, Reliable and Cost-Effective Heat Management System

Heating cable solutions for temperature-related problems

Snow melting for ramps, access ways, and footpaths

HotFlashing. HotFlashing TM

100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4

JBS-100-ECP-A COMBINATION POWER CONNECTION BOX AND DIGITAL ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

Surface Snow Melting and. Icing ElectroMelt. Introduction. ElectroMelt Self-Regulating Heating Cable System

XL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance

DESIGN GUIDELINES. THERMAL building SOLUTIONS

SEASONAL MAINTENANCE SCHEDULE

frost heave prevention

Easy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation

C910 Series. Single-point heat-tracing control system

fuel leak detection find leaks before they find you

1SC-SSC Splice Connection Kit Installation Instructions

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

INDUSTRIAL HEAT TRACING SOLUTIONS. Products & Services

RE: Extreme Cold: Preventing Ice Dams, Frozen Pipes February 13, 2015

XL-Trace System Installation and Operation Manual

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

Union County Vocational - Technical Schools Scotch Plains, New Jersey

HEAT TRACING FOR THE REFRIGERATION INDUSTRY

Technical handbook. Temperature maintenance and frost protection systems

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions

Raychem Heating System

Design Guide and Installation Details for Self-Regulating Heating Cable

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

protection Constant wattage heating cables Self-regulating heating cables Temperature controllers

SEPARATED COMBUSTION. General WARNING

H908 WinterGard Plug-in Power Connection Kit with End Seal

HTC-915-CONT. Heat-Trace Control system

Builder s Technical Sessions. Attic Ventilation. Presented by: Rob Kaethler. Presented in Partnership with: Insert your logo here

HEATRACE. Young Chang Silicone Ltd, Co. SELF-REGULATING PIPE TRACING HEATER CABLE. Installation, Operation & Maintenance Manual

Modular Sensing Cable Installation Instructions

Transcription:

Pipe Freeze Protection and Flow Maintenance ROOF ICE MELT (RIM) SYSTEM FOR CONCEALED ROOF & GUTTER DE-ICING Fire Sprinkler System Freeze Protection PRODUCT OVERVIEW The Raychem RIM System is our premier engineered, aesthetically elegant, concealed roof & gutter de-icing solution to prevent ice dams, icicles, and frozen gutter problems. The RIM system mechanically protects the selfregulating cable, provides high power output along the entire roof edge, and is ideal for new construction or renovation of buildings for all snow load areas, for residential or commercial buildings. RIM System panels secure the heating cables in a fixed heat transfer position. They are specifically designed for eaves, valleys, channels, rakes and flat roof sections and come in a variety of aesthetically pleasing colors and finishes as standard or custom options to meet any project need. This maintenance-free RIM system embeds multiple runs of high wattage IceStop self-regulating heating cable offering the highest performing heating system with the most efficient heat transfer and cable protection. It is designed for heavy snow load areas with roof snow accumulation over 15 inches, and annual snowfall of over 100 inches. This data sheet will detail this system. For color options with Aluminum cover panel please refer to RIM color guide H59379. Roof and Gutter De-Icing Melting MI RIM-E EAVE PANEL RIM-V VALLEY PANEL RIM-DT RIM-C RIM-E RIM-V RIM-R RIM-SC Melting ElectroMelt RIM-C CHANNEL PANEL RIM-LPE RIM-S Freezer Frost Heave Prevention SHOWN WITH SELF-REG CABLE RIM-LPE LOW PITCH EAVE PANEL RIM-R RAKE PANEL RIM-S SNOW MELT RIM-SC SNOW MELT CONCEALED 1 / 5 Floor Heating Technical Data Sheets

ROOF ICE MELT (RIM) SYSTEM PANEL SYSTEMS RIM-E F6231-**-**-* RIM Eave System is designed to mount on the roof eave, to minimize the formation of ice dams and icicles. RIM-Eave panels embed 3 runs of self-regulating heating cable for high power output requirements. Weight: 2,834.75 lb/1000 ft RIM-LPE F6248-**-**-* RIM Eave System, Low Pitch is specifically designed for integration with metal roof systems and for applications involving roof pitch less than 3:12. RIM-LPE panels embed 2 runs of self-regulating heating cable. Weight: 2,190,75 lb/1000 ft RIM-V F6281-**-**-* RIM Valley System is designed to mount in the roof valleys to minimize the formation of ice dams and icicles in roof valleys. RIM-V panels embed 2 runs of self-regulating heating cable. Weight: 819.50 lb/1000 ft RIM-R F6261-**-**-* RIM Rake System is designed to mount on the roof rake and direct the snow melt towards the eave. RIM-R panels embed 2 runs of self-regulating heating cable. Weight: 1,264.75 lb/1000 ft RIM-C F6221-**-**-* RIM Channel System is designed to mount on the roof and provide a heated channel for snow melt to flow from one section of the roof to the other, usually a drain or eave. RIM2-C panels embed 2 runs of self-regulating heating cable. Weight: 750.75 lb/1000 ft RIM-S F6271-**-**-* RIM Snowmelt System is designed to mount on the roof and is used to create wider snow melt paths. This panel system can be used to melt snow on roof sections between standing seams, or provide melt paths to access sections of roof. RIM-S panels embed 2 runs of self-regulating heating cable. Weight: 1,509.75 lb/1000 ft RIM-SC F6275-**-**-* RIM Snowmelt System, Concealed is designed to mount under a metal roof surface so that the entire RIM panel is concealed. RIM-SC panels embed 2 runs of self-regulating heating cable. Weight: 1,155.75 lb/1000 ft HEATING CABLES GM-1X 832100-000 IceStop Self-regulating heating cable, 120 V GM-2X 446105-000 IceStop Self-regulating heating cable, 208-277 V 2 / 5

CONNECTION KITS & ACCESSORIES ROOF ICE MELT (RIM) SYSTEM RIM-EPSC R6211-**-** RIM Eave Panel Splice Cover is designed to cover the joints between RIM-E panels on the roof. RIM-EPEB R6015-23 RIM Eave Panel End Bracket, Black is designed to cover the ends of RIM-E panels on the roof. Pipe Freeze Protection and Flow Maintenance Fire Sprinkler System Freeze Protection WPCK-R F1012 WPCK-R is a CSA Certified and UL Listed power connection kit for RIM system. Materials for one power connection kit and end seal are provided. WHES F1009 WHES is a CSA Certified and UL Listed end seal kit for RIM system. Materials for end seal are provided. Roof and Gutter De-Icing WSTK P000000229 WSTK is a CSA Certified and UL Listed splice/tee/end seal kit for RIM system. Materials for one splice or tee and end seal are provided. Melting MI JB-55 F0300 JB-55 is a CSA Certified and UL Listed junction box that can be used for a power connection kit for RIM system in conjunction with WPCK-R. Junction box dimensions 5 x5 JB-75 F0303 JB-75 is a CSA Certified and UL Listed junction box that can be used for a power connection kit for RIM system in conjunction with WPCK-R. JB-75 allows powering up to 3 cables (powered tee). Junction box dimensions 7 x5 DSH B0402 Downspout hanger (DSH ) is used to protect the heating cable from sharp edges at the corner of gutter and downspout. HFF F0110 Heater Feedthrough Fitting (HFF) is used as a gland kit when the heating cable penetrates the gutter or downspout. Melting ElectroMelt Freezer Frost Heave Prevention R6201-**-** Cable Cover Bracket is designed to mount on roofs or gutters and embeds one or two runs of self-regulating heating cable. It enhances the heat transfer from the heating cable to the snow, creating larger drain paths. RIM Adhesive/ Sealant B1626 Weight: 17 lb/1000 ft RIM Adhesive/Sealant is a silicone sealant used to attach selected RIM systems to the underlying surface. Please refer to appropriate installation instructions included with the system. 10.3 oz. Tube 3 / 5 Floor Heating Technical Data Sheets

ROOF ICE MELT (RIM) SYSTEM APPROVALS DESIGN AND INSTALLATION The IceStop heating cables are UL Listed and CSA Certified only when used with the appropriate agency-approved Thermal Management connection kits and accessories. For approvals information, refer to the IceStop heating cable data sheet H56428. For proper design and installation of a Roof Ice Melt (RIM) system, use the appropriate product design guide (H59561) and the installation instructions included with the system. GROUND-FAULT PROTECTION To minimize the danger of fire from sustained electrical arcing if the heating cable is damaged or improperly installed, and to comply with the requirements of Thermal Management, agency certifications, and national electrical codes, ground-fault equipment protection must be used on each heating cable branch circuit. Arcing may not be stopped by conventional circuit protection. Many Raychem control and monitoring systems meet the ground-fault protection requirement. 4 / 5

WWW.PENTAIRTHERMAL.COM NORTH AMERICA Tel: +1.800.545.6258 Fax: +1.800.527.5703 Tel: +1.650.216.1526 Fax: +1.650.474.7711 RIM.Customercare@pentair.com Pentair is owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice 2017 Pentair. 5 / 5