air systems Roomtop RTC-RTH 15 to 30 - L
york air-conditioning products Roomtop RTC-RTH - L A complete range from 14.6 kw up to 27.0 kw YKN2open Features New YKN2open board Possibility to be installed outdoor Scroll Compressors High COP and EER 1/4 turn on electrical panel Expansion valves for models 20, 25 and 30 High external static pressure on evaporator and condenser Digital thermostat DPC-1 and indoor air filter included RTC 15 L Nomenclature L = version Capacity range: 15 = 15 kw Product category: RTC = Cooling only RTH = Heat pump Summer RTC-RTH Evaporator Winter RTH Outdoor air Condenser Indoor air Outdoor air 4 ways valve Indoor air Compressor Compressor Standard air flow Site modification
Roomtop RTC-RTH 15 to 30 - L Technical features Cooling only models RTC 15 L RTC 20 L RTC 25 L RTC 30 L Cooling capacities kw 14.60 19.90 22.20 27.00 Power input in cooling kw 5.50 8.60 10.00 12.00 In duct outdoor side sound power level db(a) 72 74 77 81 In duct indoor side sound power level db(a) 71 73 75 75 Heat pump models RTH 15 L RTH 20 L RTH 25 L RTH 30 L Cooling capacities kw 14.10 19.90 22.20 26.80 Power input in cooling kw 5.40 8.32 10.04 11.63 Heating capacities kw 13.80 17.80 20.80 25.40 Power input in heating kw 4.84 7.15 7.89 9.67 In duct outdoor side sound power level db(a) 74 74 81 81 In duct indoor side sound power level db(a) 73 73 81 81 Common characteristics Power supply 400V/3 + N/ 50Hz Nominal current RTC / RTH A 11.6 / 11.5 19 / 19 21 / 21 23 / 23 Starting current A 64 95 111 118 Main switch (1) A 20 25 25 32 Main cable (1) Nbr.xmm 2 5 x 4 5 x 4 5 x 4 5 x 6 Cable to standard thermostat (2) Nbr.xmm 2 10 x 0.22 Evaporator fan at nominal airflow Condenser fan at nominal airflow Nett dimensions Airflow m 3 /h 3 580 4 100 5 060 5 300 Standard ESP Pa 50 50 62 62 Airflow m 3 /h 3 890 4 810 5 640 7 450 Standard ESP Pa 50 50 50 50 Height mm 557 585 650 650 Length mm 1 312 1 575 1 750 1 770 Depth mm 1 312 1 575 1 656 2 056 Nett weight RTC kg 235 305 358 420 Nett weight RTH kg 243 317 379 434 Air Systems (1) For information only. These should be checked for compliance with local regulations depending also on installation and cable type (2) Shield type cable only All the data are at EUROVENT conditions with 400V/3+N/50Hz. Cooling : Entering indoor coil temp. 27 C / 19 C WB and outdoor temperature 35 C Heating : Entering indoor coil temp. 20 C and outdoor temperature 7 C / 6 C WB Compatibility table / Codes Cooling only models Heat pump models Thermostat Delivered as standard with the unit RTC 15 L RTC 20 L RTC 25 L RTC 30 L S661241503 S661242003 S661242503 S661243003 RTH 15 L RTH 20 L RTH 25 L RTH 30 L S662041503 S662042003 S662042503 S662043003 DPC-1 Accessories or options Electrical Heaters * (in duct) Low ambient regulation Remarks Code RTC 15 L RTC 20 L RTC 25 L RTC 30 L RTH 15 L RTH 20 L RTH 25 L RTH 30 L 5 kw / 3ph. S611765653 A A A A 10 kw / 3ph. S611765583 A A A A 15 kw / 3ph. S611765513 A A A A S613111533 O S613113087 * O O O Copper-copper coils unit Contact us O O O O Blue fin Contact us O O O O A= Accessory (supplied loose). O= Option (factory fitted). * Not protected against external conditions. Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products Design details Cabinet features Build to last, all cabinet with heavy gauge galvanized steel and powder paint backed on oven. Copper-copper coils or blue fin delivered upon request. Side or bottom duct connections to be realized on site. Excellent water-tightness even with high internal negative pressure. External slopes to remove rain water. Only 4 solid points to crane. Copper-copper coil Blue fin Designed to service Quick and easy access to all components. Doors equipped with hinges and ¼ turn lock. Service valves. Inspection window for sight glass. Internal drain pan slope to remove drain water. YKtool for comissioning, monitoring and controlling unit parameters. Electrical features YKN2open regulation and control. Vertical hermetic scroll compressor, with compressor module and crankcase heater. Smooth start indoor fan. Phase detector. Main power switch. Numbered wires in cable truncking. Motor protection. Quality and ELT Design, built and tested under ISO9001 quality system certification, we are constantly listening to customer comments. For this reason, our End of Line Test ELT strives to be as close as possible to the commissioning you carry out on site.
Control System YKN2open The YKlon is a controller regulating all components and accessories. It will pro actively manage cool and heat stages to maintain a stable room temperature maximizing the efficiency. Additionally, the benefits are: Redundancy on cool and heat stages (if one step is locked out, the PCB starts another one automatically). Random start between units to minimise electrical tariff. All stages will start in sequence to reduce peak inrush. Reduces nuisance calls by using 3 times you are out on all safeties before a hard lockout occurs. Automatic restart after power failure. Compressors run time priority. Alarm output relay and led diagnostic code. No parameters to check before starting. Lockout and incident level of protection. Last 10 lockouts stored in a non-volatile memory. 4 heating stages on hot water heating. BMS connection (N2 Open protocol). Air Systems YKtool N2open The Yktool is the perfect tool to use on a regular basis for comissioning and service on site. For comissioning, it will override the thermostat and start the cooling or heating stages. Being a plug and play device, you will have direct acess to all sensors and status of each components and accessories installed (lockout & incidents, temperatures, defrost test...). Code: S613786031 Features and benefits Thermostat DPC-1 Day (normal), night (economy) and unoccupied (stand by). Lockout code on screen gives direct diagnostics. ON/OFF or programmable from dip switch setting. Day or night programmable state avoids wide internal temperature variation. 3 preset and 3 programmable profiles. Temperature override. Thermostats with integrated sensors Select the control sensor you want to use (integrated in the thermostat, return air in duct or room sensor). Turbo, normal or economy logic from dip switch setting. From 3 C to +3 C sensor offset. Average temperature with room or duct sensors. Thermostat models DPC-1 DPC-1R Code S603786044 S603786045 Roomtop RTC and RTH X 0 Rooftop All models X (1) 0 Split system VAC and VAH X 0 VCH X 0 DS-1 AS-1 Main features Strategy Turbo, normal or economy Auto restart after power failure l l Number of cool stages 2 1 2 Number of heat stages 2 1 2 Auxiliary Heat l l Automatic Heat/Cool change over l l Continuous or auto indoor fan l l Manual setback (Day/Night key) Day, night and unocuppied Override possibility l l Compressor anti short cycle l l C Range cooling / heating 10 to 32 C / 9 to 32 C Programmable, 7-day l l Lockout codes l l Outdoor air temperature l with YKlon Sensor selection l l X : Delivered as standard with the unit. O : Optional. l : Function available. X (1) : Standard but has to be ordered separately. RS-1 Duct sensor Ambiance sensor* Room sensor DS-1 AS-1 RS-1 S603786047 S603786049 S603786042 * To control up to 4 temperature sensors. To be fitted with DPC-1 version 2.0 or superior.
york air-conditioning products BMS Connection IP Network DPC-1 DPC-1 YKN2open YKN2open Light control, Power station... AHU VRF CHILLER
BMS communication through new board YKN2Open delivered as standard (N2Open protocol) Possibility to fully control the unit and monitor more than 160 variables per unit. Can be integrated with other systems like lighting, fire&security or other HVAC equipment. Fully tailored solutions available (ask JCI sales office) Sample screen DPC-1 DPC-1 DPC-1 YKN2open YKN2open YKN2open ACCESS CONTROL FIRE TVCC Fire & Security FAN COILS HVAC application