POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

Similar documents
POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2

POINT HELIDECK LIGHTS PRL-LSM LED LOW SURFACE MOUNT LIGHT

POINT ROLLOVER LIGHTS PRL LED HELIPORT INSET LIGHT

POINT ROLLOVER LIGHTS PRL LED HELIDECK SEMIFLUSH LIGHT

POINT FLASHING BEACON PFB EX LED HAZARDOUS AREA CLASS I, DIVISION 2

POINT STATUS LIGHTS PSL LED HELIDECK STATUS LIGHT SYSTEM SAFE AREA & CLASS I, DIVISION 2 (ZONE 2)

POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

Heliport & Helideck Lighting System. For Non Hazardous and Hazardous Locations. Option: Marine Treatment for superior corrosion protection

SUPPLEMENTAL INSTRUCTION SHEET POL S2 POINT OBSTRUCTION LIGHT SINGLE WITH ALARM

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

Applications. Standard Materials

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

LIGHTING TEF 9980 STATUS LIGHT, MAIN LIGHT & REPEATER LIGHT ZONE 1, ZONE 2 & SAFE AREA USER MANUAL

Vigilant LED Based Obstruction Lights

Obelux MI-2KR-A Page 1/5 ICAO Medium Intensity Type B and C, FAA L-864 and L-885, cd flashing / fixed red obstacle light

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

Rugged LED shelter lighting

Moon Visions Lighting

LMV Series W Low Profile - Medium Base

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

Product Specifications MaxLumen MRI LED Diffused Lighting

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

1. PURPOSE. This advisory circular (AC) contains the Federal Aviation Administration (FAA) specification for obstruction lighting equipment.

Airfield lighting. Product Brochure

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

High-Intensity cd Aviation Light

XLFE-4/1. Borosilicate glass globe

Vigilant LED Based Obstruction Lights

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

Vigilant LED Based Obstruction Lights

150W Explosion Proof LED Flood Light - Surface Mount Lumens - C1D V AC

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

INSTRUCTION & SERVICE MANUAL

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

ecolor Graze Powercore Linear LED surface light for wall washing and grazing

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

Date: 3/11/2019 Initiated By: AAS-100

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

REFRACTOPACK. Corrosion resistant construction allows this luminaire to be installed in corrosive and marine outdoor applications.

300W EXP LED Light - 35,000 Lm - 3' Cart Mount - Quick Change Mount - C1D1-100' 16/3 SOOW- EXP Plug

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

Explosion Proof 160 W Class 1 & 2 Fluorescent UV Light With 4 Lamps - Class 1 Division 1

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations

Choice of factory set distributions. Thermally set white polyester powder paint. Optional wet location listing

DMV Series W For Combustible Dusts

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

American Railway Engineering and Maintenance of Way Association Letter Ballot. Draft

Shipboard Electric Water Heater

Dialight Obstruction LED Solutions

standards: standards:

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

High Pressure Conductivity Monitor

WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations.

Explosion Proof Emergency Fluorescent Light Combination - Dimmable Ballast - C1D1-2 T8 lamps - 4'

Industrial 100 Watt Ultraviolet LED Light Fixture - Paint Spray Booth Approved Nanometer

! WARNING. Before using product, read and understand instructions.

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

SECTION (16460) - LOW-VOLTAGE TRANSFORMERS

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

ILED Aquarius CIRCLE-H Mk 2 Helideck Lighting System

Lighting for Hazardous & Severe Environments

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial

Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations. Description. Installation WARNING

IVR15-RPS O.D. Solid State Illuminated Rail Remote Power Supply

VACUUM VALVES AND HOSES

Dräger Polytron 5700 IR Detection of flammable gases and vapours

standard response Fusible Link Upright sprinkler VK204 (K8.0)

EVLED201 36W Led Luminaire. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 14.85

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS)

HL-2449_flg:8 pager 6/17/10 11:19 AM Page 1 Tear Drop LED Series

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

LED Evolution of a Classic

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

UTILITY LIGHT INTRODUCTION

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK120 (K8.0) TECHNICAL DATA

Transcription:

Compliances: ETL Listed to UL 1598A Marine Vessels at -40 deg C to +55 deg C ETL Listed to CSA C22.2 No. 137-M1981 & No. 250.0-08 Canada ETL Listed to UL 1598 at -40 deg C to +55 deg C IMO 2009 MODU Code (2010) paragraph 13.5.20 FAA AC 150/5390-2B Heliport Design Guide ICAO Annex 14, Volume II Registered ISO 9001:2008 UK CAA CAP 437, Chapter 4, paragraph 3.1 Transport Canada TP14371, AGA 7.17 American Bureau of Shipping (ABS) Type Approved Product ABS Green Passport per MEPC179 (59) The PRL-LSM is an 8-inch diameter surface mounted light less than 6-inches high used for metal helidecks or existing pavement heliports on the FATO perimeter. All external hardware is grade 316 (A4) stainless steel. The lens and optical assembly are sealed mechanically without the use of chemical sealants. The cable may enter via conduit or a watertight compression fitting. Silicone-filled wire nut connectors and ground lug are included for installer use. For offshore helidecks, use option -MT Marine Treatment. See specifications page 2. Standard with 2 x 1-inch NPT entries at 0 & 180-degrees Point Type Voltage Array Color Mounting & Options PRL-97004 1: 120v H: Helideck G: Green VB: Variable Brightness 2: 220v C: CAP 437 Y: Yellow LSM: Low Surface Mount Base 3: 12v DC N: NVG * W: White MT: Marine Treatment 4: 24v DC R: Red CF: Cable Gland (NPT only) B: Blue M2x: Metric Thread (M20 or M25) IR: Infrared NVG NC: NVG compatibility** SC: Switchable Color (see page 2) TB: Terminal Blocks Note: Array H brightness exceeds ICAO Annex 14 * For NVG tactical use only: PRL-97704-1N-IR-LSM-MT ** For use with visible (non-ir) array; adds IR LEDs. Option MT is recommended for all marine, high salt content air and other corrosive environments and military sites. The fixture shall be treated for marine conditions by cleaning per US Department of Defense TT-C-490 method III, pretreated with chrome-free aluminum conversion coating per US MIL-C-5541 type II, epoxy powder base coat primer and glossy polyester powder coat finish in color RAL 6003 (FED-STD-595 color #14097) dark green. Powder coating per US Department of Defense MIL-PRF-24712A type VI and oven cured. The PRL v4 H array is 4.5 watts at 120-220V The PRL v4 C array is 7.4 watts at 120-220V PRL-97004-1C-G-LSM-MT WITH MARINE TREATMENT All external hardware is grade 316 (A4) stainless steel. Metal castings are copper-free (< 0.25%) heat treated aluminum. HL-1.1.7 November, 2016

SWITCHABLE COLOR OPTION -SC Point Lighting offers a unique and proprietary designed option for two color switching within the highly certified PRL package. This is applicable to all mounting forms of the PRL in both safe area and hazardous location Class I, Division 2 and Class I, Zone 2. In addition to option SC on the PRL, this system requires use of the color switching PHC-61001 heliport controller with its option SC1 or SC2. This permits switching the perimeter lights between two (2) colors or, for military application, between one color and infrared only. Application Examples Example 1: Example 2: Example 3: Example 4: To mark a helipad as available to land (green) or as closed to landing (red). This could be for an emergency or to designate one pad for landing among two or more. Each PRL light is switchable from green to red: PRL-97004-1H-G+R-PLB-SC The required controller can manually switch the color of all perimeter lights: PHC-61001-1-SC1 with a rotary switch GREEN OFF RED An offshore marine helideck has alternating yellow and blue perimeter lights, but the owner wants the option to change all the lights to green when the rig is re-tasked. Each PRL light is switchable from either blue or yellow to green. PRL-97004-1C-B+G-LSM-MT-SC PRL-97004-1C-Y+G-LSM-MT-SC The required controller can manually switch the color of all perimeter lights: PHC-61001-1-M-SC1 with a rotary switch BLUE/YELLOW OFF GREEN A military heliport has green perimeter lights, but the operator must be able change all the lights from visible green to infrared only for NVG training or combat. Each PRL light is switchable from visible green to lights out infrared. PRL-97004-1H-G+IR-PLB-MT-SC The required controller can manually switch the mode of all perimeter lights: PHC-61001-1-SC1 with a rotary switch GREEN OFF INFRARED An offshore marine helideck has green perimeter lights and a CAP 437 helideck status light system. Upon manual or automatic activation of the Point PSL status light system, the PRL perimeter lights change to red and flash in sync warning pilots not to land. Each PRL light is switchable from green to red. PRL-97004-1C-G+R-LSM-MT-SC The PSL status light system is ordered with PHC combination helideck lighting controller that includes the integral PSL control unit. In the AUTO position the default color for the lights is green, but upon activation of the PSL the perimeter lights switch to flashing red, but may be manually switched to steady-burning red: PHC-61001-1-M-SCSL-SL with a rotary switch GREEN OFF AUTO RED HELIPORT LIGHTING CONTROLLER PHC-61001-1-SC1 MARINE HELIDECK LIGHTING CONTROLLER PHC-61001-1-M-SCSL-SL Integral PSL Control Unit

PRL-LSM LED SPECIFICATIONS The PRL-LSM LED (specify: color), (specify: voltage) 50/60 Hz surface mounted light shall not exceed 150mm in height. The unit shall operate properly within an input voltage supply range of 93V to 144V for 120V units and for 176V to 250V for 220V units. Within the preceding ranges, the output to the LED board shall be a controlled, stabilized constant current. The heliport lights shall be listed Suitable for Use in Wet Locations to UL1598A Marine Vessels (for AC), UL1598 2nd Edition Luminaries; CSA C22.2 No. 250.0-08, 2nd Edition; UL50 11th Edition Standard for Enclosures for Electrical Equipment and CSA C22.2 No. 94-M91 Special Purpose Enclosures for use at -40 deg C to +55 deg C and sealed to IP66 ingress protection. Per ICAO Annex 14, Volume II, Figure 5-9, Array H complies with a minimum of 15 candelas in green under 5-degrees vertical and a minimum of 30 candelas at the peak beam range. Array C complies with CAP 437 which is brighter in certain areas up to a maximum of 60 candelas. The light shall be copper-free cast aluminum and assembled with all external hardware grade 316 (A4) stainless steel. The lens and lamp housing (optical assembly) shall be sealed mechanically without the use of chemical sealants. Entry to the light housing shall be by means of conduit or watertight cable compression fitting(s). The manufacturer shall include silicone-filled wire connectors for use by the installer for watertight connections. The LED lighting circuits shall be remotely dimmable by means of a heliport controller designed and produced by the lighting manufacturer. Option -VB: For use with the PHC-61002 or PHC-61003 adjustable brightness heliport controller, this option is required. The PHC Heliport Lighting Controller shall incorporate an IEC approved surge suppressor and current limiting circuit breakers on each load output. The LED light shall have a tested and verified power consumption not to exceed (see chart next page). The unit shall be warranted to withstand an ambient temperature range of: +130 deg F (+55 deg C) to -67 deg F (-55 deg C). The light casting shall be powdercoat painted for corrosion resistance certified by the manufacturer to comply with the US Military Standard Salt Fog Test conducted per MIL-STD-810F, Method 509.4, Procedure I, paragraph 4.5.2. All hardware shall be stainless steel. The outer glass lens shall be smooth and rounded to reduce the adhesion of dirt, ice and snow. The glass shall be clear to maximize light transmissivity. The color emitting LEDs shall meet the chromaticity requirements of US MIL-C-25050. The high output LED s shall be the latest technology providing uniform light output. The LED average life shall exceed 100,000 hours. The LEDs shall be soldered in a factory set position to insure consistent light output. Wire mounted raised LEDs that can be bent out of position shall be unacceptable and cause for rejection. The LED board shall be treated with a protective dielectric conformal coating for protection from moisture and corrosion. The power supply board shall include short circuit and open circuit protection and the unit shall be protected from line surges by metal oxide varistors (MOVs). There shall be a clear design element for the dissipation of LED heat to insure the LEDs do not fail prematurely. Note: It is strongly recommended that the circuit also be directly protected by a Point Lighting Corporation surge suppression device such as in a PHC, SPU or PRC unit. PRL shall be secured to the LSM mounting base by three (3) socket head stainless steel screws supplied by the manufacturer. A ground lug shall be included as standard. The LED aviation inset light shall be POINTSPEC Series PRL-97004-LSM manufactured by Point Lighting Corporation.

POWER CONSUMPTION Code Type Voltage Frequency Watts* VA* -1H Array H 120 AC 50/60 Hz 4.5 5.24-2H Array H 220 AC 50/60 Hz 4.5 5.47-3H Array H 12 DC --- 4.0 --- -4H Array H 24 DC --- 4.0 --- -1C Array C 120 AC 50/60 Hz 7.4 8.4-2C Array C 220 AC 50/60 Hz 7.4 8.0-3C Array C 12 DC --- 6.2 --- -4C Array C 24 DC --- 6.0 --- Option NC Add 1.0 watt and 1.1 VA *Power consumption for AC units includes the effect of the unit s power factor which accounts for the difference between watts and volt-amperes. Measurements were made at the nominal AC voltages. The operating range for 120v units is 93-144v. The operating range for 220v units is 176-250v. Point Lighting Corporation recommends return for factory repair and refurbishment of LED PRL lights RECOMMENDED TOOLS Point Lighting Corporation recommends return for factory repair and refurbishment of LED PRL lights. In the event of field service, the PL10839 preset torque wrench kit use with the instruction manual is recommended to assure proper resealing of the fixture. PL10860 Tool, T-handle Wrench For the three socket head screws fixing the PRL optical subassembly to the LSM mounting base. PL10839 Tool, Preset Torque Wrench Kit For the socket head screws fixing the PRL lens clamp ring and for fixing the power supply subassembly. Consult the factory and the manual before attempting field repair.

Night Vision Goggles (NVG) Point Lighting Corporation offers options for combining infrared and color LEDs to render our lights visible with and without NVG. Select option NC. Instruction Sheet: IS97004-LSM LED Life (hours): 100,000 Housing Dia: 8.0 (203) Height: 5.75 (146) Bolt Circle (4): 9.75 (248) Bolt Hole diam: 0.406-inch 10.3 mm Weight: 12.0 lbs 5.5 kg Replacement Parts PL10523-C Lens, Clear* PL10901-G-C LED Array C, Green PL10901-G-H LED Array H, Green PL10926-G-C LED Array C, Green with -NC PL10926-G-H LED Array H, Green with -NC PL10530 Gasket, Lens Upper PL10531 Gasket, Lens Lower PL10532 Gasket, Lamp Housing PL10049-4-6 Gasket, Base PL10524-125 Screw, Socket Head PL10839 Tool, preset torque wrench kit PL10860 Tool, T-handle wrench * All PRL v4 lights use a clear outer lens. P O I N T L I G H T I N G C O R P O R A T I O N Mail: P.O. Box 686, Simsbury, CT 06070 Plant: West Dudley Town Rd, Bloomfield, CT Tel 01 860.243.0600 USA Fax 01 860.243.0665 email: Info@PointLighting.com website: www.pointlighting.com