Operating instructions. For the operator. Operating instructions VRT 350. Room temperature-controlled controller GB, IE

Similar documents
Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

multimatic Operating instructions AT, BE (de), CH (de), DE VRC 700f/4

multimatic Operating instructions Operating instructions For the operator AT, BE (de), CH (de), DE VRC 700f/4 Publisher/manufacturer Vaillant GmbH

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

Operating instructions

Operating instructions

Operating instructions. For the operator. Operating instructions. ecotec. Gas fired wall hung high efficiency boiler.

For the operator/for the heating engineer. Operating and Installation Manual VRC 430. Weather compensator VRC 430

Supplement to operating and installation manual no for the VR 81 remote control unit

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

Operating instructions

Operating and Installation Manual VRC 430f. Weather compensator controller with radio transmission. For the operator / for the heating engineer

Operating instructions

Operating instructions

allstor buffer cylinder Instructions for use Instructions for use For the operator Publisher/manufacturer Vaillant GmbH

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

VR 90 Remote control unit

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

BM Programming Module. For the heating engineer Installation instructions

R. Room temperature controller with solar control FR 120. Operating instructions for the user (2012/02)

ecotec pro Operating instructions Operating instructions For the operator GB, IE Gas-fired wall-hung high-efficiency boiler

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

User Instructions For TopTronic RS-30

Operation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation

Operating instructions

AUTO CM CM USER GUIDE

Operating instruction. Remote control station WCM-FS /

CS027 User Instructions

User Guide for EHE & EHE Programmable Room Thermostat

irad Wireless Controller

For the owner. Operating manual. ecotec. Gas wall boilers with condensing appliance technology VU 466/4 VU 656/4

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

ecotec plus boiler user guide

User reference guide. Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB

User Manual THR870CUK Programmable Thermostat

R. Boiler Energy Management System FW 200. Operating Instructions for the User (2010/05)

Heating Controller SDC. District Heating Controller DHC 43 OPERATING INSTRUCTIONS

Operation manual. Daikin Altherma Low temperature split EHBH04CBV EHBH08CBV EHBH11CBV EHBH16CBV

For the owner and the heating engineer. Operating and Installation Manual. timeswitch 140. Two-channel 5/2 or 7-day full programmer

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

danfoss Heating Solutions 5

C-Stat 17-ZW User Instructions

ECL Comfort 210 / 296 / 310

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort

ATC32U03 igate Communicating, Programmable Thermostat

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

USERS GUIDE. Electronic Timer, 7 day. LOGIC+ Combi, LOGIC Combi & LOGIC Combi E 24, 30, 35

MAKING MODERN LIVING POSSIBLE. FP975 7-Day Electronic Programmer. User Guide. Danfoss Heating

MAKING MODERN LIVING POSSIBLE. CP715Si. Electronic 2-Channel Common Timebase Programmer for Heating and Hot Water. User Guide.

RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY

Operation manual. Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

ATC32U01 igate Communicating, Programmable Thermostat

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

WIRED REMOTE CONTROLLER

Cooling kit UTW-KCL*D. Installation instructions FR NL EN DE IT. (Compatible with high-flow circulation pump, code UTW-PHF*D)

Installation Guide. ECL Comfort 210, application A Table of Contents

Operating Instructions

atmocraft VK 654/9-1654/9 DE/AT/GB/CZ/SK/HU/PL/HR/SI/SCG

Vokèra OpenTherm 711 without external sensor connected

Evolution Control. Zone Control Homeowner s Guide

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

TYBOX PAC. * _rev1* User guide. Programmable thermostat for heat pumps

Operating Instructions for use by heating contractor. VITOTRONIC r 100 VITOTRONIC r 300-K IMPORTANT

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

Infinity Control. Homeowner s Guide. The New Feeling of Comfort

Condensing Boiler RS100 Controller Training Program

Model: Slimline-RF. 1 Slimline Series

User Manual THR872CUK Wireless Programmable Thermostat

Mixer module VR 61. Operating and Installation Manual. Mixer module for VRC 430 / VRC 430f

Vokèra OpenTherm 711 with external sensor connected

Operation Manual NOVA LIVE S

Installation and servicing instructions

YEAR-ROUND COMFORT EVOLUTION CONTROL ZONE CONTROL HOMEOWNER S GUIDE. The Ultimate Home Comfort System.

MCD User Manual

3 Channel Multi-Purpose Programmer User Instructions

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

Model: Touch-RF. 1 Wireless Series

Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual:

DX2002 OPERATING AND PROGRAMMING INSTRUCTIONS

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

Installation and user manual

Elegance. SMT-700 User manual. Ver

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

EB-Therm 300 E / SSTL MONTERINGSANVISNING / INSTALLATION INSTRUCTIONS LEGGEANVISNING / ASSENNUSOHJEET

Digital Thermostat Models: VS30W and VS30B

Varenummer: Version:

- Data Brochure tekmarnet 4 Thermostat 542e

/2010 US/CA

Installation, Start-Up, and Operating Instructions

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

USER'S OPERATING INSTRUCTIONS

Transcription:

Operating instructions For the operator Operating instructions VRT 350 Room temperature-controlled controller GB, IE

Legal information Document type: Product: VRT 350 Target group: Language: Operating instructions Operator EN Document number_version: 0020135485_00 Created on: 06.02.2012 Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Telefon +49 21 91 18 0 Telefax +49 21 91 18 28 10 info@vaillant.de www.vaillant.de Vaillant GmbH 2012 These instructions, or extracts thereof, may only be printed with the written consent of Vaillant GmbH. All designations of products in these instructions are brand names/trade marks of the companies in question. We reserve the right to make technical changes.

Contents Contents 1 Notes on the documentation... 5 1.1 Symbols and signs used... 5 1.1.1 Symbols... 5 1.2 Structure of warnings... 5 1.3 Observe other applicable documents... 5 1.4 Document storage... 5 1.5 Applicability of the instructions... 5 2 Safety... 6 2.1 Action-related warnings... 6 2.2 Required personnel qualifications... 6 2.2.1 Operator... 6 2.3 General safety information... 6 2.3.1 Installation only by a skilled tradesman... 6 2.3.2 Risk of scalding as a result of hot drinking water... 6 2.3.3 Danger caused by a malfunction... 6 2.3.4 Frost damage caused by switching the unit off... 6 2.3.5 Frost damage caused by excessively low room temperature... 6 2.4 CE label... 7 2.5 Intended use... 7 3 Overview of the equipment... 8 3.1 Product features... 8 3.2 Type designation and serial number... 8 3.2.1 Type designation... 8 3.2.2 Identification plate... 8 3.2.3 Serial number... 8 3.3 Unit design... 8 3.4 Control function... 8 3.4.1 Heating installation... 8 3.4.2 Hot water generation... 9 3.4.3 VR 66 Control Centre... 9 3.5 Frost protection function... 9 4 Operating... 10 4.1 Operating structure... 10 4.1.1 Access level for the operator... 10 4.1.2 Access level for the skilled tradesman... 10 4.1.3 Menu structure design... 10 4.1.4 Basic display... 10 4.1.5 ion level... 11 4.1.6 Setting level... 11 4.2 Operating concept... 11 4.2.1 Operation in the basic display... 12 4.2.2 Operating example: Changing the date... 12 4.3 Overview of the menu structure... 14 4.4 Overview of setting and read-out options... 16 4.4.1 Using the overview in table format... 16 4.4.2 Entering your own settings... 16 4.4.3 Overview of operating modes... 17 4.4.4 Overview of operating levels... 17 5 Operating and display functions... 19 5.1 Information... 19 5.2 Settings... 19 5.2.1 Setting desired temperatures... 19 5.2.2 Setting timer programs... 20 5.2.3 Days away from home scheduling... 22 5.2.4 Language selection... 22 5.2.5 Setting the date... 22 5.2.6 Setting the time... 22 5.2.7 Changing over to daylight saving time... 23 5.2.8 Setting the display contrast... 23 5.2.9 Setting the offset room temperature... 23 5.2.10 Changing heating circuit naming... 23 5.2.11 Resetting to factory setting... 23 5.2.12 Installer level... 23 5.3 Operating modes... 23 5.3.1 Operating modes for the heating circuit... 24 5.3.2 Modes for hot water production... 24 5.4 Special operating modes... 25 5.4.1 Cylinder boost... 25 5.4.2 Party... 25 5.4.3 1 day away from home... 25 0020135485_00 VRT 350 Operating instructions 3

Contents 5.5 Messages... 25 5.5.1 Service message... 25 5.5.2 Fault message... 25 6 Saving energy... 27 6.1 Controlling the room temperature... 27 6.2 Reducing the room temperature... 27 6.3 Uniform heating... 27 6.4 Using thermostatic radiator valves and weather compensators or room thermostats... 27 6.5 Do not cover controllers... 27 6.6 Ensuring economic hot water generation... 27 7 Service and troubleshooting... 28 7.1 Cleaning the controller... 28 11.9 Day temperature... 32 11.10 Level of protection... 32 11.11 Protection class... 32 11.12 Status message... 32 11.13 Thermostatic radiator valve... 32 11.14 Flow temperature... 32 11.15 Hot water generation... 32 11.16 Time periods... 33 11.17 Timer program... 33 11.18 Access level for the operator... 33 11.19 Access level for the competent person... 33 Index...34 7.2 Detecting and rectifying faults... 28 8 Decommissioning... 29 8.1 Replacing the controller... 29 8.2 Recycling and disposal... 29 9 Warranty and customer service... 30 9.1 Warranty... 30 9.2 Customer service... 30 10 Technical data... 31 10.1 Controller... 31 11 Glossary... 32 11.1 ion level... 32 11.2 Mode... 32 11.3 Setting level... 32 11.4 Fault message... 32 11.5 Heating circuit... 32 11.6 Heating installation... 32 11.7 Night temperature... 32 11.8 Room temperature... 32 4 Operating instructions VRT 350 0020135485_00

Notes on the documentation 1 1 Notes on the documentation 1.1 Symbols and signs used 1.1.1 Symbols The following symbols may appear: 1.3 Observe other applicable documents When operating the controller, always take note of all operating instructions that are supplied with the other components of the heating system. 1.4 Document storage Warning symbol ( Page 6) Information symbol Symbol for a required action. Symbol for the result of an action. Symbol for the completion of records and checklists Symbol for a required qualification Keep these operating instructions and all other applicable documents safe so that they are available whenever required, they are kept for the full service life of the unit, they are available to all subsequent operators. 1.5 Applicability of the instructions These operating instructions apply to appliances with the following article numbers only: Article number Great Britain 0020124475 Table 1.1: Article number Symbol for a required tool Symbol for the specification of a technical value 1.2 Structure of warnings Warning signs are identified by an upper and lower separating line and are laid out according to the following basic principle: Danger! Type and source of danger Explanation of the type of danger. Measures for averting the danger. 0020135485_00 VRT 350 Operating instructions 5

2 Safety 2 Safety 2.1 Action-related warnings Classification of action-related warnings The action-related warnings are classified in accordance with the severity of the possible danger using the following warning symbols and signal words: Warning symbols and signal words Danger! Imminent danger to life or risk of severe personal injury Danger! Risk of death from electric shock Warning! Risk of minor personal injury Caution! Risk of material or environmental damage 2.2 Required personnel qualifications These instructions are aimed at those who are able to operate a heating installation but do not have any special technical knowledge or experience. 2.3 General safety information 2.3.1 Installation only by a skilled tradesman Installation of the unit can be only carried out by an approved, skilled tradesman. This skilled tradesman is also responsible for proper installation and start-up. 2.3.2 Risk of scalding as a result of hot drinking water There is a risk of scalding at the hot water draw-off points if the set target temperature is greater than 60 C. Young children and elderly persons are particularly at risk, even at lower temperatures. a moderate target temperature. 2.3.3 Danger caused by a malfunction Ensure that air can circulate freely around the controller, and that the controller is not covered by furniture, curtains or other objects. Ensure that all radiator valves in the room where the controller is fitted are fully open. Only operate the heating installation when it is in a technically perfect condition. Ensure that any faults and damage that may negatively affect safety are rectified immediately. 2.2.1 Operator Definition: Instructed operator The operator is charged with operation and maintenance of the unit. He/she must ensure compliance with maintenance intervals. He/she does not require any special technical knowledge or experience. The operator must have been instructed in the following topics by the authorised skilled tradesman. General safety information Function and location of safety devices on the system Operation of the unit Energy-saving operation Maintenance operations 2.3.4 Frost damage caused by switching the unit off If you switch off the heating installation, parts of the heating installation may be damaged by frost. Do not disconnect the heater from the power mains. Leave the heating installation main switch in the "1" position. 2.3.5 Frost damage caused by excessively low room temperature If the room temperature is set too low in individual rooms, sections of the heating installation might be damaged by frost. If you are absent during a frosty spell, ensure that the heating installation remains in operation and the rooms are warmed adequately. Please note the frost protection function. 6 Operating instructions VRT 350 0020135485_00

Safety 2 2.4 CE label The CE label documents that the controller complies with the fundamental requirements of the relevant directives. 2.5 Intended use State-of-the-art The controller is a state-of-the-art unit manufactured in accordance with recognised safety regulations. Even so, in the event of inappropriate or non-intended use, impairment of the unit and other property may arise. The controller controls a heating installation with a Vaillant heater with ebus interface in a way that is room-controlled and time-dependent. The controller can control the hot water generation of a connected domestic hot water cylinder. Improper use Any other use, or use beyond that specified, shall be considered improper use. Any direct commercial or industrial use is also deemed to be improper. The manufacturer/supplier is not liable for any resulting damage. The user alone bears the risk. Improper use of any kind is prohibited. Other applicable documents Intended use includes: observing the included operating, installation and servicing instructions for the Vaillant product and any other parts and components of the system compliance with all inspection and servicing conditions listed in the instructions. 0020135485_00 VRT 350 Operating instructions 7

3 Overview of the equipment 3 Overview of the equipment 3.3 Unit design 3.1 Product features Room-temperature-controlled Controls heater and hot water Plain text display Illuminated display 1 3.2 Type designation and serial number 3.2.1 Type designation Abbreviation Explanation VRT 3xx Vaillant controller Room temperature controlled 5 2 Table 3.1: Type designation 4 3.2.2 Identification plate The identification plate is located inside the controller and is not accessible from the outside. 3.2.3 Serial number The 10-digit article number can be found in the serial number. You can view the serial number under "Menu Information Serial number". The article number is found in the second line of the serial number. 3 Image 3.1: Controller (front view) 1 Display 2 Diagnosis socket 3 Right selector button 3.4 Control function 4 Control knob 5 Left selector button The controller controls the Vaillant heating system and hot water generation of a connected domestic hot water cylinder. 3.4.1 Heating installation The controller is a room-temperature-controlled controller and must be installed in the living room. You can use the controller to set the desired temperature for different times of the day and for different days of the week. The temperature sensor measures the room temperature and sends the values to the controller. At lower room temperatures, the controller switches the heater on. Once the room temperature reaches the desired set temperature, the controller switches the heater off. The controller therefore reacts to the fluctuations of the room temperature and constantly controls the room temperature to the temperature that you have set. 8 Operating instructions VRT 350 0020135485_00

Overview of the equipment 3 3.4.2 Hot water generation You can use the controller to set the temperature and time for the hot water generation. The heater heats the water in the domestic hot water cylinder until it reaches the set temperature. You can set a time period during which hot water should be available in the domestic hot water cylinder. 3.4.3 VR 66 Control Centre If a VR 66 Control Centre is connected, you can control two independent heating circuits with just one VRT 350 controller; e.g. one heating circuit is in the single-occupancy house and the second heating circuit is in a guest apartment in this building. In this case, one controller is always the main controller (Zone 1) and the other controller is the auxiliary controller (Zone 2). For Zone 1, which is controlled via the main controller, all of the functions are available to you. For Zone 2, you can use the auxiliary controller to set the desired temperature for different times of the day and different days of the week. 3.5 Frost protection function The frost protection function protects the heating system and apartment from frost damage. The frost protection function monitors the room temperature. If the room temperature falls below 5 C, the controller switches the heater on and controls the system to a target room temperature of 5 C. exceeds 5 C, the heater is switched off but the room temperature monitoring remains active. 0020135485_00 VRT 350 Operating instructions 9

4 Operating 4 Operating 4.1 Operating structure The controller has two superordinate operating levels. 4.1.1 Access level for the operator Through the access level for the operator, you access important information and set-up options which do not require any special prior knowledge. Via a menu structure, you can access configurable or read-only values. 4.1.2 Access level for the skilled tradesman The skilled tradesman will set further values for the heating installation via the access level for the skilled tradesman. The settings may only be made by someone with specialist knowledge; this level is therefore code-protected. 4.1.3 Menu structure design The menu structure of the controller is split into three levels. There are two selection levels and one setting level. From the basic display, you can access selection level 1 and, from there, you can access the menu structure for one level up or down. The setting level is accessed from the lowest selection level. 4.1.4 Basic display 8 7 6 5 Auto 01.07.11 19,5 C Desired temperature 20,0 C Menu Image 4.1: Basic display 1 Date 2 Current room temperature 3 Time 4 Current function of the right-hand selector button (soft key function) Mode 15:34 5 Current function of the left-hand selector button (soft key function) 6 Desired temperature 1 2 3 4 7 Symbol for heating mode in «Auto» mode 8 Mode set for the heating mode values of the heating installation. If you make a setting on the controller, the display on the screen switches from the basic display to the display for the new setting. The basic display appears when you: press the left-hand selection button and thus exit selection level 1. do not operate the controller for more than 5 minutes. 4.1.4.1 Symbols for the heating mode in the «Auto» operating mode Symbol Meaning Heating mode within a set time period (comfort mode) Heating mode outside a set time period (set-back mode) Table 4.1: Symbols for heating mode 4.1.4.2 Soft key function Both selector buttons have a soft key function. The current functions of the selector buttons are displayed in the bottom display line. Depending on the selection level selected in the menu structure, the list entry or the value, the current function of the left-hand selection button may differ. the current function of the right-hand selector button may differ. If, for example, you press the left function key, the current function of the left function key switches from «Menu» to. 4.1.4.3 Menu If you press the left-hand selector button, «Menu», you switch from the basic display to selection level 1 of the menu structure. 4.1.4.4 Mode If you press the right-hand selector button, «Operating mode», you access the settings under «Operating mode» directly from the basic display. This is a quick way to modify the of «HEATING 1». The basic display is the permanently visible display on the screen. The basic display shows the current settings and 10 Operating instructions VRT 350 0020135485_00

Operating 4 4.1.4.5 Desired temperature 4.1.6 Setting level Depending on the operating mode, the desired temperature may be greyed out on the basic display. This is the case, for example, in «Summer mode». As heating is not operational in «Summer mode», and therefore the heating circuit is off, there is no desired temperature. 4.1.5 ion level 5 HEATING 1 Day Night set-back 20,0 C 15,0 C Change 1 2 3 4 4 3 2 Menu Information Desired temperatures Time programmes 1 Image 4.3: Display fields in the setting level 1 Current selection level 2 Values 3 Highlighting (white font on black background) shows the current selection. 4 Current functions of the right and left-hand selector buttons (soft key functions) 5 Setting level Image 4.2: Display fields in the selection levels 1 Scroll bar (only appears if there are more list entries than can be shown at once on the display) 2 Current functions of the right and left-hand selector buttons (soft key functions) 3 ion level list entries 4 Current function or selection level Through the selection levels, you navigate to the setting level in which you wish to read or change settings. In the setting level, you can select the values you wish to read or change. 4.2 Operating concept The controller is operated using two selector buttons and a rotary knob ( Page 8). You can use the selector buttons to navigate through the selection levels and the setting level in the menu structure, select a setting, confirm a value, activate an operating mode, cancel a change to a value. You can use the rotary knob to navigate through the list entries of a selection level by turning the rotary knob to the left or right highlight a selection level or a setting level, change a selected value. The display shows a highlighted selection level, a setting level or a highlighted value with white font on a black background. A flashing highlighted value means that you can change the value. Note If you do not operate the controller during a period of more than 5 minutes, the basic display appears in the display again. 0020135485_00 VRT 350 Operating instructions 11

4 Operating 4.2.1 Operation in the basic display From the basic display, you can change the «Desired day temperature» directly for the current day by turning the rotary knob. Desired day temperature Only today: 18 C For Permanent Change Press OK OK 4.4: Requesting a permanent change of the desired temperature In the display, a request appears asking if you wish to change the «Desired day temperature» for the current day or on a permanent basis. 4.2.1.1 To change the «Desired day temperature» for the current day only Turn the rotary knob to set the desired temperature. The display switches back to the basic display after 12 seconds. The set desired temperature applies only until the end of the active time period of the current day. 4.2.1.2 To change the «Desired day temperature» permanently 1. Turn the rotary knob to set the desired temperature. 2. Press the right-hand selector button, «OK». The display switches to the basic display. The new desired day temperature is applied permanently. 4.2.2 Operating example: Changing the date Auto 01.07.11 19,5 C Desired temperature 20,0 C 15:34 The controller is now in selection level 1. The lefthand selector button now has the function (to the next selection level up), the right-hand selector button has the function (the next selection level down). Menu Information Desired temperatures Time programmes Image 4.6: ion level 1: «Information» 3. Turn the rotary knob until the «Basic settings» list entry is highlighted. Menu Time programmes Days away scheduling Basic settings Image 4.7: ion level 1: «Basic settings» Time programmes 4. Press the right-hand selector button,. The controller is now in selection level 2. Basic settings Language Date / Time Display Image 4.8: ion level 2: «Language» 5. Turn the rotary knob until the «Date/Time» list entry is highlighted. Menu Image 4.5: Basic display Mode 1. If the display does not show the basic display, press the left-hand selector button,, until the basic display appears again. 2. Press the left-hand selector button, «Menu». 12 Operating instructions VRT 350 0020135485_00

Operating 4 Basic settings Language Date / Time Display Date / Time Date Time Daylight saving 14.03.11 08:15 Off Image 4.9: ion level 2: «Date/Time» 6. Press the right-hand selector button,. The controller is now in the «Date» setting level. The value for the day is highlighted. The left-hand selector button now has the function (to the next selection level up), the right-hand selector button has the function «Change» (the value). Date / Time Date Time Daylight saving 13.03.11 08:15 Off Change Image 4.10: Setting level: Value for day is highlighted 7. Press the right-hand selector button, «Change». The highlighted value starts to flash; you can now change the value by turning the rotary knob. The left-hand selector button now has the function «Cancel» (the change), the right-hand selector button has the function «OK» (to confirm the change). Cancel Image 4.12: Setting level: Change has been saved OK 9. Press the right-hand selector button, «OK», to confirm the change. The controller has stored the modified date. Date / Time Date Time Daylight saving Image 4.13: Setting level: One level back 14.03.11 08:15 Off Change 10. If the highlighted value that is flashing is correct, press the right-hand selector button «ok» again. The left-hand selector button now has the function. 11. Press the left-hand selector button, several times to switch back to the next selection level up and to access the basic display from selection level 1. Date / Time Date Time Daylight saving 13.03.11 08:15 Off Cancel OK Image 4.11: Setting level: Accept the changed value 8. Turn the control knob to change the value. 0020135485_00 VRT 350 Operating instructions 13

4 Operating 4.3 Overview of the menu structure Second heating circuit If a second heating circuit is available, you can also use the main controller for Zone 1 to access the functions shown in grey. The display of the auxiliary controller for Zone 2 does not show the functions that are shown here in grey. Auto 01.07.11 19,5 C Desired temperature 20,0 C Menu Mode 15:34 Menu Information Desired temperatures Time programmes Information System status Contact details Serial number System Status Water pressure Dom. hot water OK 2,3bar Charging Information System status Contact details Serial number Contact details Installer Phone HEATING 1 HEATING 1 ---------------------------------- Day temperature 20,0 C Night temp 15,0 C Information System status Contact details Serial number Serial number 123456 7890123456 7890123456 VRT350 HEATING 1 Auto day temp to 22:10 away from 24.12.11 away to 26.12.11 Menu Information Desired temperatures Time programmes Desired temperatures HEATING 1 Domestic hot water HEATING 1 Day Night set-back 20,0 C 15,0 C Change Desired temperatures HEATING 1 Domestic hot water Domestic hot water Dom. hot water 43 C Cancel OK Menu Information Desired temperatures Time programmes Time programmes HEATING 1 Domestic hot water Monday Period 1: Period 2: Period 3: 06 : 00-22 : 00 : - : : - : Time programmes HEATING 1 Domestic hot water Monday Period 1: Period 2: Period 3: 05 : 30-22 : 00 : - : : - : 4.14: Menu structure part 1 14 Operating instructions VRT 350 0020135485_00

Operating 4 Menu Days away scheduling Basic settings Installer level Days away scheduling Start End Temperature 01.09. 11 10.09. 11 15,0 C Change Menu Days away scheduling Basic settings Installer level Basic settings Language Date / Time Display Language English OK Basic settings Language Date / Time Display Date / Time Date Time Daylight saving 29. 07. 11 15: 34 Off Change Basic settings Language Date / Time Display Display Display contrast 11 Change Basic settings Offset Change heating circuit name Factory reset Offset Offset room temp 0,0K Change Basic settings Offset Change heating circuit name Factory reset Change names Heating 1 HEATING 1 Change Basic settings Offset Change heating circuit name Factory reset Factory reset? Time programme Everything No No Menu Basic settings Installer level ------------------------------------------------- Enter code 000 OK 4.15: Menu structure part 2 0020135485_00 VRT 350 Operating instructions 15

4 Operating 4.4 Overview of setting and read-out options 4.4.1 Using the overview in table format You will find below an overview of the setting and read-out options. If the "Increment/" column is blank, these are values that you can read but not adjust. If a value cannot be set at the factory, for example because it is currently being measured, the "Factory reset" column will be blank. If nothing is entered in the "ion level 2" column, you will be taken from "ion level 1" directly to the "Setting level". 4.4.2 Entering your own settings In the last column, "Own setting", enter the values that have been set by you. 16 Operating instructions VRT 350 0020135485_00

Operating 4 4.4.3 Overview of operating modes The activated operating mode is shown in the top left of the basic display. The right-hand selector button can be used to navigate from the basic display directly to the settings under «Operating mode». If you have activated an advanced function, the display indicates the advanced function. VR 66 Control Centre If there is a second heating circuit, you can only set the operating modes using the main controller. The operating mode that is set applies for Zone 1 and for Zone 2. Mode Setting Factory reset Own setting Current mode Auto Automatic mode Active Summer Summer mode Not active Day Comfort mode Not active Set-back Set-back mode Not active System OFF System OFF Not active Special operating mode Cylinder boost Active, Not active Not active Party function Active, Not active Not active 1 day away from home Active, Not active Not active Table 4.2: Operating modes 4.4.4 Overview of operating levels ion level 1 Information ion level 2 System status Contact details Serial number Setting level Values Unit Increment/ min. max. System Status Current value Water pressure Current value bar Hot water Current value Charged, charging HEATING 1 Day temperature Current value C 0.5 20 Set-back temperature Auto day temp until away from away to Installer Phone Unit number 5 30 Current value C 0.5 15 5 30 Current value Current value Current value Current values Permanent value hr:min dd.mm.yy dd.mm.yy Factory reset Own setting If the VR 66 is connected, the functions shown in italics are only available for Zone 1 and these are only shown in the display for the main controller. 0020135485_00 VRT 350 Operating instructions 17

4 Operating ion level 1 Desired temperatures Timer programs Days away from home scheduling ion level 2 HEATING 1 Hot water circuit HEATING 1 Hot water circuit Setting level Values Unit Increment/ min. max. Day Set-back 5 30 C 0.5 20 15 Hot water 35 70 C 1 60 Individual days and blocks Time period 1: Start - End Time period 2: Start - End Time period 3: Start - End Individual days and blocks Time period 1: Start - End Time period 2: Start - End Time period 3: Start - End 00:00 24:00 hr:min 10 min 00:00 24:00 hr:min 10 min Start 01.01.00 31.12.99 End 01.01.00 31.12.99 Temperature Frost protection or 5 dd.mm.yy dd.mm.yy Mon, Tue, Wed, Thu, Fri, Sat, Sun and Mon - Fri, Sat - Sun, Mon - Sun Mon, Tue, Wed, Thu, Fri, Sat, Sun and Mon - Fri, Sat - Sun, Mon - Sun Factory reset Mon - Fri: 06:00-22:00 Sat: 07:30-23:30 Sun: 07:30-22:00 Mon to Fri: 05:30-22:00 Sat: 07:00-23:30 Sun: 07:00-22:00 Day.Month.Year 01.01.10 Day.Month.Year 01.01.10 30 C 0.5 Frost protection Basic settings Language able language Date/Time Date 01.01.00 31.12.99 dd.mm.yy English Day.Month.Year 01.01.10 Time 00:00 24:00 hr:min 10 min 00:00 Daylight saving time Off, Auto Display Display contrast 01 15 1 8 Offset Setting heating circuit names Default setting (reset) Room temperature -3.0 3.0 K 0.5 0.0 HEATING 1 1 10 Letter/numberspace A to Z, 0 to 9, Timer programs Yes, no No Everything Yes, no No Installer level Enter code 000 999 1 000 Off HEATING 1 Own setting If the VR 66 is connected, the functions shown in italics are only available for Zone 1 and these are only shown in the display for the main controller. Table 4.3: Overview of operating levels 18 Operating instructions VRT 350 0020135485_00

Operating and display functions 5 5 Operating and display functions The controller offers various functions, operating modes and advanced functions for controlling the heating installation. With the functions, you can read information, and set desired temperatures, periods and basic settings. With the operating modes, you select whether the heating installation should be operated in automatic or manual mode. With the advanced functions, you can change the active operating mode for the heating circuit and hot water generation in special situations quickly and with time restrictions. 5.1 Information You can set the functions using the left-hand selector button: «Menu». the «Information» list entry in selection level 1 to reach selection level 2 with the «System status», «Contact details» and «Serial number» list entries. The path details given at the start of each function description indicate how you reach this function in the menu structure. The table "Overview of operating levels" and the overview of the menu tree show you which functions are available for Zone 2 via the auxiliary controller. The desired «day temperature» is the temperature you wish to have in the rooms during the day or when you are at home (Comfort mode). The desired «night temperature» is the temperature that you wish to have in the rooms during the night or when you are away from home (Set-back mode). 5.2.1.2 Hot water generation Danger! Risk of being scalded by hot water. There is a danger of scalding at the hot water draw-off points if the temperatures are greater than 60 C. Young children and elderly persons are particularly at risk, even at lower temperatures. the temperature so that nobody is at risk. «Menu» «Desired temperatures» «Domestic hot water» You can only use the controller's functions and setting options for hot water generation if a domestic hot water cylinder is connected to the heating installation. You can set the desired «Hot water circuit» temperature for the hot water circuit. 5.2 Settings 5.2.1 Setting desired temperatures This function is used to set the desired temperatures for «HEATING 1» and hot water generation. 5.2.1.1 Heating circuit Caution! Risk of damage due to frost. If rooms are not adequately heated, this may cause damage to the building and to the heating installation. If you are absent during a frosty spell, ensure that the heating installation remains in operation and provides adequate frost protection. «Menu» «Desired temperatures» «HEATING 1» You can set two different desired temperatures for the heating circuit. 0020135485_00 VRT 350 Operating instructions 19

5 Operating and display functions 5.2.2 Setting timer programs 5.2.2.1 Showing time periods for one day Temperature 21 16 Desired night temperature Desired day temperature Desired night temperature Desired day temperature Desired night temperature Desired day temperature Desired night temperature Period 1 Period 2 Period 3 06:00 08:00 16:30 18:00 20:00 22:30 Time Image 5.1: Example: Three time periods in one day The «Time programmes» function can be used to set the time period for the heating circuit and hot water generation. If you have not set any time periods, the controller uses the time periods set in the factory settings. 20 Operating instructions VRT 350 0020135485_00

Operating and display functions 5 5.2.2.2 Setting time periods for days and blocks You can set individual days or blocks of days for which the time periods should apply: Monday, Tuesday, Wednesday, Thursday, Friday, Saturday, Sunday Monday - Friday, Saturday - Sunday, Monday - Sunday For each day and block, you can set up to three time periods. Note The time periods set for a day have priority over the time periods set for a block. Example: Time periods for individual days Desired temperature «Day»: 21 C Desired temperature «Night»: 16 C Time period 1: 06.00-08.00 Time period 2: 16.30-18.00 Time period 3: 20.00-22.30 Within the time periods, the controller brings the room temperature to the set desired «Day» temperature (Comfort mode). Outside the time period, the controller brings the room temperature to the set desired «Set-back» temperature (Set-back mode). Example: Time periods separate for each day Monday Time period 1: 06.00-07.30 Saturday Time period 1: 07.30-10.00 Time period 2: 12.00-23.30 Example: Time periods for blocks Monday - Friday Period 1: 06:30-08:00 Period 2: 12:00-13:00 Period 3: 17:00-22:00 Saturday - Sunday Period 1: 08:00-22:00 5.2.2.3 Setting time programmes quickly If, for example, you require a different time period for just one working day in the week, first set the times for the entire block «Monday - Friday»". Then set the deviating time period for the working day. 5.2.2.4 Display and change deviating times in the block Monday - Sunday Period 1: Period 2: Period 3: Image 5.2: Identification of different days!! :!! -!! :!!!! :!! -!! :!!!! :!! -!! :!! If you view a block in the display and have defined a deviating period for a day in this block, then the display indicates the deviating times in the block with «!!». Individual days vary from Mo - Su block. OK Image 5.3: Exception to the time programme message If you press the right-hand selector button, a message appears on the display which informs you about deviating periods. You do not need to align the times. The set times for the block marked with «!!» can be viewed and changed if you press the right-hand selector button «OK» in the display. 5.2.2.5 For the heating circuit «Menu» «Timer programs» «HEATING 1» The time programmes are only effective in the «Automatic mode» ( Page 24). The desired temperature that you set in the «Desired temperatures» function applies in each set time period. Within the time period, the controller switches to Comfort mode and the heating circuit heats the connected rooms up to the desired «day temperature». Outside this time period, the controller switches to the set-back mode and the heating circuit heats the connected rooms to the desired «set-back temperature». 0020135485_00 VRT 350 Operating instructions 21

5 Operating and display functions Set the time period for the heating circuit so that each time period: starts approx. 30 minutes before the time at which the rooms should reach the desired «day temperature». ends approx. 30 minutes before the time at which the rooms should reach the desired «set-back temperature». 5.2.2.6 For hot water generation «Menu» «Timer programs» «Hot water circuit» You can only use the controller's functions and setting options for hot water generation if a domestic hot water cylinder is connected to the heating installation. The timer programs are only effective for hot water generation in the «Automatic mode» and «Summer mode» operating modes. In each set time period, the desired «Hot water circuit» temperature that you set in the «Desired temperatures» function applies. If, during the time period, the cylinder temperature drops by 5 C below the desired «Hot water circuit» value, the domestic hot water cylinder is heated back up to the desired «Hot water circuit» temperature (recharged). At the end of a time period, the controller switches the hot water generation off until the start of the next time period. Set the time periods for hot water generation so that each time period: Starts approx. 30 minutes before the time at which the water in the domestic hot water cylinder should have reached the desired «Hot water circuit» temperature. Ends approx. 30 minutes before the time at which you no longer need any hot water. 5.2.3 Days away from home scheduling «Menu» «Days away from home scheduling» «HEAT- ING 1» With this function, you can set a period with a start and end date and a temperature for days during which you are away from home. Thus, you do not need to change time periods for which you have set, for example, no reduction of the desired temperature over the course of the day. Frost protection is activated. While the «Days away from home scheduling» function is activated, it has priority over the set operating mode. At the end of the specified period, or if you cancel the function, the heating system returns to the pre-set mode. 5.2.4 Language selection Note During installation, the skilled tradesman sets the desired language. All functions are displayed in the set language. «Menu» «Basic settings» «Language» If the language of e.g. a service technician differs from the set language, you can change the language using this function. Caution! It may not be possible to operate the controller if the wrong language is selected. If you select a language that you do not understand, you can no longer read the text in the controller display and can no longer operate the controller. Only select a language that you understand. However, if the text in the display should appear in a language that you do not understand, you can set a different language. 5.2.4.1 Set a language that you understand 1. Press the left-hand selection button repeatedly until the basic display appears. 2. Press the left-hand selection button again. 3. Rotate the rotary knob clockwise until the dotted line appears. 4. Then rotate the control knob anticlockwise until the second list entry above the dotted line is highlighted. 5. Press the right-hand selection button twice. 6. Turn the control knob (to the right or left) until you find a language you understand. 7. Press the right-hand selection button. 5.2.5 Setting the date «Menu» «Basic settings» «Date/Time» «Date» this function to set the current date. All controller functions that contain a date relate to the set date. 5.2.6 Setting the time «Menu» «Basic settings» «Date/Time» «Time» this function to set the current time. All controller functions that contain a time relate to the set time. 22 Operating instructions VRT 350 0020135485_00

Operating and display functions 5 5.2.7 Changing over to daylight saving time «Menu» «Basic settings» «Date/Time» «Day-light savings» You can use this function to set whether the controller automatically changes over to daylight saving time, or whether you want to do this manually. «Auto»: The controller automatically changes over to daylight saving time. «Off»: You have to change over to daylight saving time manually. Note Daylight saving time means Central European summer time: Start = last Sunday in March, End = last Sunday in October. 5.2.8 Setting the display contrast «Menu» «Basic settings» «Display» «Display contrast» You can set the display contrast in relation to the brightness of the surroundings, to ensure that the display is clearly legible. 5.2.9 Setting the offset room temperature «Menu» «Basic settings» «Offset» «Room temperature» A thermometer is integrated in the controller for measuring the room temperature. If you have another thermometer in the same room and compare the values with each other, the temperature values may constantly differ from each other. Example One room thermometer constantly shows a temperature that is one degree higher than the current room temperature on the controller display. With the «Room temperature» function, you can offset the temperature difference in the controller display by setting a correction value of +1 K (1 K corresponds to 1 C). K (Kelvin) is a unit for the temperature difference. Inputting a correction value affects the room temperature compensator. 5.2.10 Changing heating circuit naming «Menu» «Basic settings» «Change heating circuit naming» You can now modify the factory-specified heating circuit names as you wish. The name is limited to 10 characters. 5.2.11 Resetting to factory setting You can reset the settings for the «Time programmes» or for «Everything» to the factory setting. Timer programs «Menu» «Basic settings» «Factory reset» «Time programmes» With «Timer programs», you reset all the settings you have made in the «Timer programs» function to the default setting. All other settings that include times, such as «Date/Time», are not affected. While the controller is resetting the timer program settings to the default settings, «In process» is shown on the display. The basic display is then displayed. Everything Caution! Risk of a malfunction. The «Everything» function restores all settings to the factory settings, including those set by the skilled tradesman. It may be the case that it is no longer possible to operate the heating installation after this. Arrange for the skilled tradesman to reset all settings to factory settings. «Menu» «Basic settings» «Factory reset» «Everything» While the controller is resetting the settings to the factory settings, «in process» is shown on the display. Then the installation assistant appears in the display, which only the skilled tradesman may operate. 5.2.12 Installer level The Installer level is reserved for the skilled tradesman and is therefore protected by an access code. At this operating level, the skilled tradesman can make the necessary settings. 5.3 Operating modes Use the right-hand selector button, «Operating mode» to set the mode directly. The path details given at the start of each mode description indicate how you reach this mode in the menu structure. 0020135485_00 VRT 350 Operating instructions 23

5 Operating and display functions 5.3.1 Operating modes for the heating circuit 5.3.1.1 Automatic mode «Operating mode» «Automatic mode» The automatic mode controls the heating circuit in accordance with the set desired temperature and the set time periods. Within the time periods, the controller brings the room temperature to the set desired «Day» temperature (Comfort mode). Outside the time period, the controller brings the room temperature to the set desired «Set-back» temperature (Set-back mode). 5.3.1.2 Summer mode «Operating mode» «Summer mode» The heating function is switched off for the heating circuit and the frost protection function is active. The hot water generation controls the controller in accordance with the time period that has been set for this purpose. 5.3.1.3 Comfort mode «Operating mode» «Comfort mode» The «Comfort mode» operating mode brings the heating circuit to the set desired «day temperature», without taking account of a time period. 5.3.1.4 Set-back mode «Operating mode» «Set-back mode» The «Set-back mode» operating mode controls the heating circuit to the set desired «Set-back» temperature, without taking time periods into consideration. 5.3.1.5 System OFF «Operating mode» «System OFF» The heating function is switched off. The frost protection function is activated. 5.3.2.1 Automatic mode The automatic mode controls the hot water generation in accordance with the set desired temperature for «Hot water circuit» and the set time periods. In the «Timer programs» function, you have set time periods for hot water generation. If you have not set any time periods, the controller uses the time period set in the factory settings for hot water generation. Within the time period, hot water generation is switched on and maintains the hot water in the DHW cylinder at the preset temperature. Outside the period, hot water generation is switched off. 5.3.2.2 Summer mode The summer mode controls the hot water generation in accordance with the set desired temperature for «Hot water circuit» and the set time periods. In the «Timer programs» function, you have set time periods for hot water generation. If you have not set any time periods, the controller uses the time period set in the factory settings for hot water generation. Within the time period, hot water generation is switched on and maintains the hot water in the DHW cylinder at the preset temperature. Outside the period, hot water generation is switched off. 5.3.2.3 Comfort mode The comfort mode controls the hot water generation in accordance with the set desired temperature for «Hot water circuit» without taking time periods into account. 5.3.2.4 Set-back mode Hot water generation is switched off and the frost protection function is activated. 5.3.2.5 System off Hot water generation is switched off and the Frost protection function is active. 5.3.2 Modes for hot water production The operating mode for hot water generation corresponds to the heating circuit operating mode that has been set. You cannot set a deviating operating mode. 24 Operating instructions VRT 350 0020135485_00

Operating and display functions 5 5.4 Special operating modes The advanced functions can be activated directly from any mode using the right-hand selector button «Operating mode». The path details given at the start of each advanced function description indicate how you can access this advanced function in the menu structure. 5.4.1 Cylinder boost «Operating mode» «Cylinder boost» If you have switched off hot water generation or require hot water outside a time period, activate the «Cylinder boost»advanced function. The advanced function heats the water in the domestic hot water cylinder once, until the set desired «Hot water circuit» temperature is reached or until you cancel the advanced function early. The heating system will then return to the pre-set mode. 5.4.2 Party «Operating mode» «Party function» If you want to switch on the heating circuit and hot water generation temporarily, e.g. during a party, activate the advanced function «Party». This means you do not need to change the settings on the heating system for short periods of time. The advanced function brings the room temperature to the set desired «Day» temperature, in accordance with the set time periods. If the display shows «Party function active», you can use the rotary knob to set the desired «Day» temperature for the heating circuit. The advanced function is deactivated when the next time period is reached or if you cancel the advanced function early. The heating system will then return to the pre-set mode. 5.4.3 1 day away from home «Operating mode» «1 Day away from home» If you are only away from home for one day, e.g. for a day trip, activate the «1 Day away from home» advanced function. This means you do not need to change the time periods that you have set by increasing the room temperature during the day, for example. This advanced function brings the room temperature to the desired «Set-back» temperature. Hot water generation is switched off and frost protection is activated. If the display shows «1 Day away from home active», you can use the rotary knob to set the desired «Set-back» temperature for the heating circuit. The advanced function is automatically deactivated after 24:00 hours or if you cancel the advanced function first. The heating system will then return to the pre-set mode. 5.5 Messages 5.5.1 Service message If a service is required, the controller displays a service message in the display. Caution! Risk of damage to the heating installation due to failure to perform maintenance work. A service message indicates that the heating installation must be serviced by the skilled tradesman. Failure to observe these service messages could lead to material damage or failure of the heating installation. If the controller displays a service message, inform a skilled tradesman. Service Heat Generator 1 Desired temperature 20,0 C Menu 22,5 C Image 5.4: Example of a service message The following service messages may appear: «Boiler service» «Service» (of the heating installation) 5.5.2 Fault message Mode If a fault occurs in the heating system, the controller displays a fault message in the display. 0020135485_00 VRT 350 Operating instructions 25

5 Operating and display functions Caution! Risk of damage to the heating installation due to failure to perform troubleshooting work. A fault message indicates that the skilled tradesman must perform troubleshooting or repair work on the heating installation. Failure to observe these fault messages could lead to material damage or failure of the heating installation. If the controller displays a fault message, inform a skilled tradesman.! Heat Generator 1 fault Image 5.5: Example of an fault message If the controller shows a fault message in the display instead of the basic display and you press the left-hand selector button then the basic display appears again. You can also read current fault messages under "Menu Information System status Status". As soon as a fault message for the heating system appears, the «Status» setting level will display «Fault». In this case, the right function key has the function «Display». 26 Operating instructions VRT 350 0020135485_00

Saving energy 6 6 Saving energy 6.1 Controlling the room temperature It is normally not necessary to heat bedrooms or seldomused rooms to 20 C. Adjust the room temperature according to the purpose of use of the room. Set the room temperature only as high as would be enough for your comfort level. Note An extra degree would mean increased energy consumption of about 6%. 6.2 Reducing the room temperature You can reduce the temperature most simply and reliably by using controllers with individually selectable time programmes. If you reduce the room temperature by more than 5 C, you do not save any additional energy, because increased heating capacities would then be required for the next full heating period. Only for longer absences, e.g. during holidays, is it worthwhile to lower the temperatures further. Reduce the room temperature at night and in your absence. During the set-back times, set the room temperature to a lower temperature than during full heating times. During a longer absence, set the temperature using the «Days away from home scheduling» function. 6.3 Uniform heating If you are only heating one room or individual rooms in your dwelling, the unheated adjoining rooms are also heated in an unregulated manner through walls, doors, windows, roofs and floors. The capacity of the radiators in the heated rooms is obviously not enough for such an operating mode. It is then not possible to heat up the heated rooms sufficiently (the same effect arises when doors between heated and unheated/barely heated rooms are left open). Heat all rooms in your dwelling evenly and according to their use. 6.4 Using thermostatic radiator valves and weather compensators or room thermostats Thermostatic valves on all radiators maintain the room temperature exactly once they have been set. If the room temperature rises above the value set on the sensor head, the thermostatic radiator valve shuts off automatically; when the temperature drops below the defined value, it opens again. Exception: The thermostatic valves on the radiators in the room in which the controller is fitted must be turned fully on. The radiators are then controlled by the controller and thus maintain the set room temperature. Adjust the room temperature to your individual requirements using thermostatic radiator valves. You can use thermostatic radiator valves or a room thermostat to ensure the economical operation of your heating installation. 6.5 Do not cover controllers The controller must be able to detect the circulating air unhindered. Covered thermostatic radiator valves can be equipped with remote sensors and thus still work. Do not cover your controllers with furniture, curtains or similar objects. 6.6 Ensuring economic hot water generation Set the desired «Hot water circuit» temperature of your domestic hot water cylinder only to the temperature you actually need, and under no circumstances higher than 60 C. You should also use the «Timer programs» function for hot water generation in «Automatic mode» or «Summer mode». Set the time period so that the water is brought to the desired «Hot water circuit» temperature shortly before it is needed, e.g. in the morning after getting up and in the evening after you return home. If you do not need any hot water for a longer period of time, switch hot water generation off. If you need hot water rarely or outside the set time periods, use the function «Cylinder boost». 0020135485_00 VRT 350 Operating instructions 27