Supra-Clean and Supra-Poly SPE Solutions. Solid Phase Extraction Columns

Similar documents
Thermo Scientific Dionex SolEx SPE Cartridges

Agricultural. drugs of abuse. Food & Beverage. Pesticides SOLID PHASE EXTRACTION. Inject. Wash Elute. Cartridges. Concentrate. Silica.

Thermo Scientific Dionex AutoTrace 280 SPE Instrument. Automate Large-Volume. Solid-Phase Extractions

Solid Phase Extraction using the 96-well Format ISOLUTE -96 Fixed Well Plates and ISOLUTE Array 96-well Plates

Sample Preparation Solid Phase Extraction Disks Cartridges. Horizon Technology, Inc. Salem, NH USA

How Important is Performance to your SPE Method Development?

Reliable elimination of particles and micro organisms PAGE Protein Precipitation Fast and effective sample clean up of biological samples

Tubing spares and piping accessories. Gas purification and control 1 Moisture Traps,Carbon traps 2 Gas Purification Panels 3 Gas Control Box

RapidTrace + Automated SPE Workstation. Instruments. Accessories Racks Vial Adapters Test Tubes O-Rings Miscellaneous

Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples

Fundamentals of Solid-Phase Extraction (SPE): Principles and Practical Tips for Developing Sample Preparation Methods

Thermo Scientific Rocket Evaporator. Revolutionary solvent evaporation complete laboratory workflow

Automação de SPE utilizando sistema robótico Triplus RSH autosampler. Nova Analitica

Auto SPE-06Plus Solid Phase Extraction System. Reeko Instrument USA

Automated Fractionation System that Increases Recovery and Optimize Precision of Solid Phase Extraction Methodology

Order all the parts and accessories needed at one time Reduced learning curve for rapid implementation

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Chromatography. Research Supplies. 2014/2015 Catalog

get mass. without massive work. [ 3100 MASS DETECTOR ]

Use of Automation to Achieve

Tekmar-DOHRMANN The 3100 Sample Concentrator From ManualLib.com

Spark Holland introduces

Application Note. The Agilent 1200 Infinity Series Online SPE Solution for the Highest Sensitivity. Author. Abstract.

AppNote 3/2009. Automation of Solid Phase Extraction Methods using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

Enhancing Throughput of Online SPE Analysis of Pesticides in Wastewater The Agilent 1200 Infi nity Series Online SPE Solution

XENOSEP. SPE Systems for EPA Method 1664A. The Easiest, Most Cost Effective Way to Increase Productivity

The Road to Recovery. Mapping Advanced Sample Preparation Techniques for GC, GC-MS and HPLC Analysis

DETERMINATION OF PAH In Particulate Matter PM 10 with SPE/EVAporation

P2 P2 P2 P3 P3 P3-4 P5 P5-p6 P6 P7 P7 P7-P8

Analysis of Pharmaceuticals and Personal Care Products in Groundwater by Online SPE and LC/MS/MS

From Sample to Vial. Automated Sample Prep Solutions. Extraction Cleanup Concentration

Gagnez avec «David» Mighty MEPS contre les cartouches «Goliath» SPE

Pretreatments to LLE

PURITY GRADES OF LAB REAGENTS

Advancing the power of SPE. Intelligent Automated Solid Phase Extraction. SmartPrep Brochure

Automated Sample Preparation: SPE GPC - EVAporation SUPERIORITY BY ADAPTATION. Visit us at

Advancing the power of SPE. Intelligent Automated Solid Phase Extraction. SmartPrep Brochure

FREESTYLE SPE UNIQUE POSSIBILITIES FOR SOLID PHASE EXTRACTION

Biotage VacMaster 10 & 20 Sample Processing Station. Operation Manual

Evaporators, Sealers and other Equipment

On-line SPE Enrichment of Trace Organic Contaminants in Water and Juices

High Volume Injection up to 5 ml with the Agilent 1200 Infinity Series Online SPE Solution for Highest Sensitivity

detectors UltiMate 3000 Variable Wavelength Detectors

Typical Sample Preparation Process & Highlighted Areas for Horizon Technology SmartPrep Extractor Automation and XcelVap Evaporation

300 series HPLC autosamplers

Methods of solid phase extraction. Methods of solid phase extraction

Application Note. Authors. Abstract

Chemistry Instrumental Analysis Lecture 29. Chem 4631

APPLICATION NOTE DETERMINATION OF THE HYDROCARBON-INDEX DIN EN ISO :2000. APPLICATION NOTE As of July 2017, Version: 1.

Methods of Desiccation

Without the Dry Down. Successful Bioanalytical Sample Preparation. Microelution 96-Well SPE Plates

Tool-free LC connections for HPLC, UHPLC and nano LC systems

DETERMINATION OF PAH In Particulate Matter PM10 With SPE/EVAporation

Online SPE-UHPLC-MS. CHRONOS for Control & System Integration. Flexible autosampler for sample preparation. Superior UHPLC system for analysis

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System

AppNote 6/2008. Automated SPE and Fast GC-ECD Analysis of PCBs in Waste Oil KEYWORDS ABSTRACT INTRODUCTION. MACH, Fast GC-ECD, SPE, PCB, waste oil

JSB is an authorised partner of DETERMINATION OF THE HYDROCARBON-INDEX DIN EN ISO :2000. i n s p i r a t i o n m e e t s i n n o v a t i o n!

Rapid Quantification of Polar and Semipolar Pesticide Metabolites with Combined Online SPE and Direct Injection

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

Soxtec 200 series Solvent Extraction Solution

Standard Operating Procedure for Oil & Grease Method EPA1664A

HPLC Column Ovens and Temperature Controllers

[ ACQUITY QDa DETECTOR ] SEPARATING BEYOND QUESTION BRINGING THE POWER OF MASS DETECTION TO YOU

Accuracy Starts Here. Agilent Bond Elut Specialty, Disk and Bulk SPE Selection Guide

Solvent Evaporation. Fast, Reliable and Affordable

AAnalyst 700 Atomic Absorption Spectrometer

Improving Productivity, Quality and Security

Technical Specifications & Pricing

AAnalyst 600/800 atomic absorption spectrometers

THE RIGHT CONSUMABLES FOR YOUR GC APPLICATIONS. TurboMartix Headspace and Headspace Trap Samplers Consumables and Supplies Reference Guide

MultiPurpose Sampler MPS robotic series

Optimizing the Performance of the Agilent 1290 Infinity Evaporative Light Scattering Detector

On Line SPE LC/MS/MS Applications

Anhydro Spray Drying FOR THE PHARMACEUTICAL INDUSTRY

Anhydro Drying Systems FOR THE PHARMACEUTICAL INDUSTRY

Thermo Scientific Dionex UltiMate 3000 Fluorescence Detectors

QAQC LABS ANALYTICAL DRYING

OPTICAL FIBER SOLUTIONS

PROTOCOL FOR FREE LIPID SOP

Direct Injection and Online SPE LC/MS/MS for the Determination of Pharmaceuticals and Personal Care Products (PPCPs) in Water Samples

Before digging into the 10 things you should know let s start with a brief explanation of the process.

Solid Phase Extraction (SPE) for the Analysis of Semivolatile. According to EPA Method 625. Derick Lucas, PhD R&D Sample Preparation Chemist

Presenter: Malcolm McLaughlin Date: 04/04/2019. A Review of Medical Device and Optical Critical Cleaning

Chemistry diaphragm pumps

MiniWAVE Microwave Digestion Made Easy

An Automated SPE Procedure and Analysis for the Extraction of Chlorpromazine and Thioridazine from Plasma Application Note 213

This document is a preview generated by EVS

LSM Quadrant Source and Measure Unit for LED Production Tests. Two Global Leaders. One Complete Solution.

SPE SPE. Solid Phase Extraction 3. Strong bases strata-x-cw, p.12 Acids strata-x-aw, p.13 On-line extraction cartridge Strata C18 20 x 2.0 mm, p.

Use of Automation to Achieve High Performance SPE

AMSCO Washer-Disinfectors. Central Sterile Services DISCOVER POWERFUL WASHING WITH INCREASED EFFICIENCIES. One Integrated Approach to Healthcare

Anhydro Small Scale Plants

FREESTYLE QUATTRO ACCECLEAN ELUVAC GPC COLUMNS IMMUNOAFFINITY COLUMNS SAMPLE SAMPLE PREPARATION PRODUCTS PREP

Agilent 1290 Infinity II Vialsampler Data Sheet

Agilent Vac Elut SPS 24 Manifold User Guide

GEA Niro drying systems. We know what makes outstanding polymers. engineering for a better world. GEA Process Engineering

John Morris Scientific Service plus Solutions

FORENSICS GLASS BLOCK MANIFOLD INNOVATION THROUGH CHEMISTRY

MICROPLATE EVAPORATORS

Transcription:

Supra-Clean and Supra-Poly SPE Solutions Solid Phase Extraction Columns

Imagine how much faster, easier and more efficient your sample preparation would be if your Solid Phase Extraction (SPE) solutions were precisely manufactured for guaranteed reproducibility. Not just column to column. Not just batch to batch. But lot to lot no matter how many days, weeks or years between production times. That s exactly the kind of confidence and convenience you can expect with the innovative line of Supra-Clean silica-based and Supra-Poly polymer-based SPE cartridges and columns from PerkinElmer. Our Precise-Bed Technology provides precision and manufacturing tolerances of + 1%, ensuring guaranteed repeatability and optimized recovery reproducibility. The distribution and size of particles is controlled through stringent manufacturing processes, and each finished product is delivered with an individual quality certificate. Experience the difference for yourself. Or to be more exact experience the uniformity. SPE Column Competitor SPE Column Spherical silica and consistent particle distribution enable smaller elution volumes and better, more reproducible purification, concentration and recovery. Performance Comparison of PerkinElmer Spherical SPE Media vs. Leading Irregular SPE Silica. 24 18 12 6 0 250 x 4.6 mm column Hexane - IsoPropanol (97/3) Flow rate: 1.0 ml/min PSI: 1 bars UV: 254 nm A- Tri-Terbutylbenzene B- Diethyl Phthalate IR60-40/63SI SPE Supra-Clean 60-50SI V 1 < V 2 2 4 6 PerkinElmer s smaller, more homogeneous, spherical media deliver sharper, narrower peaks for faster, more accurate sample insight. V 1 V 2 Consistently. Excellent. Performance. The unsurpassed reproducibility of SPE solutions is the result of a unique bed-packing technique and spherical media. Columns are evenly and consistently filled with particles sized for optimum distribution, delivering a level of performance unattainable with the irregularly shaped silica used in competitive solutions. PerkinElmer s homogeneous filling and mono-dispersed spherical media not only provide unparalleled reproducibility, they also deliver superior performance. Sample diffusion through the media is better than in other systems, improving flow efficiency and avoiding channeling and clogging due to fines. This enables smaller sample sizes to be used without compromising recovery levels, dramatically reducing solvent volumes, analytical costs and processing times. With PerkinElmer SPE solutions, you can work faster and more costeffectively, all while experiencing the complete recovery, reproducibility and reliability you need for consistently excellent results. Answering Your Needs. Empowering Your Lab. Ideal for a broad array of analytes and matrices, SPE solutions are available in a variety of formats including Large Reservoir Capacity (LRC) columns, Polypropylene (PP) columns and cartridges, and glass columns. Each technology is offered with a wide selection of polymer and silica sorbents, and large and small sample volumes (50µL-1L) allow you to perform scalable analyses depending upon your required detection limits. 2

Choosing a Solution to Suit Your Method To find the ideal SPE column for your particular application, simply follow the flow diagram below, selecting your path based on the options at each junction. Your Sample Type of Matrix Aqueous Organic Analyte Solubility Water Follow same path as Organic Water Organic Solvents Analyte Neutral Ionic (Follow same path as Ionic analyte) Ionic Neutral Neutral Analyte Polarity Non-Polar Moderately Polar Polar Cationic Bases Anionic Acids Non-Polar Non-Polar Polar Recommended Reverse Phase Ion Exchange Reverse Phase Normal Phase Recommended SPE Products Supra-Clean C18 Supra-Clean 300Å C4 Supra-Clean Phenyl (PH-S) Supra-Clean LCC Supra-Clean REC18 Supra-Clean REC18 SPE Strong Cation Exchange (SCX) SPE Weak Cation Exchange (WCX) Supra-Clean Mixed-Mode (MM3) Supra-Clean Strong Anion Exchange (SAX) Supra-Clean Amino (NH2-S) Supra-Clean Mixed-Mode (MM1) Supra-Clean Mixed-Mode (MM2) Supra-Clean C18 Supra-Clean 300Å C4 Supra-Clean Phenyl (PH-S) Supra-Clean Cyano (CN-S) Supra-Poly Extreme Capacity 1500 m 2 /g (XC) Supra-Clean Amino (NH2-S) Supra-Poly 1200 m 2 /g (XWP)* Supra-Poly (ATH, ATL, AEV)** Supra-Clean Florisil (FL-S) Supra-Clean Silica (SI-S) Supra-Clean Amino (NH2-S) Supra-Clean Polyamine (P6) * (XWP) = Extra Wide Particle **(ATL) = Lipophilic (AEV) = Advanced Environmental (ATH) = Hydrophobic/Hydrophilic www.perkinelmer.com/spe 3

A Wide Array of Columns for a Broad Range of Applications. Chemistry Phase Benefit ph Range Description Load Capacity Supra-Clean (Spherical Silica) CN-S Hydrophilic 1-8 Extraction of Apolar and Mid-Polar Compounds. FL-S Hydrophilic 1-8 Extraction of Organochlorine and Polychlorinated Biphenyls. NH2-S Hydrophilic 1-8 Extraction of Apolar and Mid-Polar Compounds. P6 * Hydrophilic 1-8 Extraction of Flavones, Chalkones, Anthraquinones. SI-S Hydrophilic 1-8 Extraction of Polar Compounds. 300Å C4 Hydrophobic 1-8 Extraction of Apolar and Mid-Polar Compounds. C18 Hydrophobic 1-8 Extraction of Apolar and Mid-Polar Compounds. LCC Hydrophobic 1-8 Extraction of Apolar and Mid-Polar Compounds. PH-S Hydrophobic 1-8 Extraction of Apolar and Mid-Polar Aromatic Compounds. REC18 Hydrophobic 1-8 Extraction & Purification of Mid-Polar & Apolar compounds including 100% Water Solvents. SAX Ion Exchange 1-8 Extraction & Selective purification of acid compounds. SCX Ion Exchange 1-8 Extraction & Selective purification of basic compounds. WCX Ion Exchange 1-8 Extraction & Selective purification of strong base compounds. MM1 Mixed Mode 1-8 Extraction & Very Selective purification of basic compounds. MM2 Mixed Mode 1-8 Extraction & Very Selective purification of very basic compounds. MM3 Mixed Mode 1-8 Extraction & Very Selective purification of acidic compounds. Supra-Poly (Spherical Polymers) 0.3meq/g exchange capacity, 3mg/100mg 0.7meq/g exchange capacity, 7mg/100mg 0.22meq/g exchange capacity, 2.2mg/100mg 0.09meq/g exchange capacity, 0.9mg/100mg 0.10meq/g exchange capacity, 1.0mg/100mg 0.14meq/g exchange capacity, 1.4mg/100mg XC Extreme Capacity 0-14 Polar & non-polar compounds (XC < 3000D) Aqueous or organic solvent. High capacity due to high surface area. XWP Extreme Capacity, Wide Pore 0-14 Protein/peptide cleanup in bio-fluids. Polar and non-polar compounds. High capacity due to high surface area. ATH Hydrophilic 1-13 Mixed hydrophilic/hydrophobic interations. Mid-polar and apolar compounds in apolar and polar solvents. ATL ** Lipophilic 0-14 Excellent alternative to high flow silica for crude samples. Mid-polar & non-polar compounds (<3000D). AEV *** n.a. 1-12 High extraction flow of non-polar and mid-polar compounds in water. * Nylon 6 ** polystyrene-divinylbenzene *** polystyrene-co-2-hydroxyethyl methacrylate Benefits of Supra-Poly SPE. Even without a specifically designed application kit, developing methods for virtually any sample matrix or family of compounds is easy with the large number of chemistries (20+), wide ph range (1-14) and broad array of bed capacities available in PerkinElmer s Supra-Poly product line. Each column contains macro-porous polymers with ultra-pure, pharmaceutical-grade spherical particles that optimize every stage of SPE extraction. Compared with traditional silica, Supra-Poly columns offer shorter analysis times, greater load capacity, and reduced solvent usage (minimizing both procurement and disposal costs). In fact, no SPE solution is more effective at getting your samples to your instruments faster or with a greater degree of reproducibility. 4

Manifolds, Selection Kits and Application Packs to Streamline Your Sample Preparation. For greater method development simplicity and sample throughput, PerkinElmer offers a variety of pre-prepared kits and column manifolds. SPE Manifolds Allow you to process up to 24 samples simultaneously. Seamlessly integrate with columns to extend the system s performance and reproducibility. Feature polypropylene or stainless steel needle valves and tips with minimum dead volume. Rugged stopcocks are reusable and provide independent flow control. SPE Manifolds and Accessories Qty/pack Part Numbers Cover, Gasket, 12 Stopcocks 12 N9306621 Cover, Gasket, 24 Stopcocks 24 N9306628 Drying Attachment 12 Positions 12 N9306625 Drying Attachment 24 Positions 24 N9306632 Glass Chamber 12 Positions 12 N9306620 Glass Chamber 24 Positions 24 N9306627 Needles Polypropylene 12 Positions 12 N9306622 Needles Polypropylene 24 Positions 24 N9306629 Needles, Stainless Steel 12 Positions 12 N9306623 Needles, Stainless Steel 24 Positions 24 N9306630 Stopcocks 12 Positions 12 N9306624 Stopcocks 24 Positions 24 N9306631 Vacuum Manifold Complete Set 12 Positions 12 N9306619 Vacuum Manifold Complete Set 24 Positions 24 N9306626 SPE Selection Kits Selection kits enable quick column selection for development of reproducible and repeatable SPE methods. SPE Supra-Clean Column Selection Kits Weight/Volume Qty/pack Part Numbers Extraction of Acidic, Basic and Neutral Compounds from Aqueous or Organic Matrix 100mg/3mL 50 N9306602 Pre-Concentration of Hydrophobic Compounds from Aqueous Matrix 200mg/3mL 50 N9306595 Pre-Concentration of Hydrophobic Compounds from Aqueous Matrix 200mg/6mL 50 N9306594 Extraction of Hydrophobic Compounds from Aqueous Matrix 500mg/3mL 50 N9306597 Pre-Concentration of Hydrophilic Compounds 500mg/3mL 30 N9306599 Removal of Polar Compounds from Aqueous and Organic Matrix 500mg/3mL 30 N9306601 Extraction of Carboxylic Acids and Strong Bases from Aqueous Matrix 500mg/6mL 40 N9306603 Extraction of Hydrophobic Compounds from Aqueous Matrix 500mg/6mL 50 N9306596 Extraction of Weak Bases from Aqueous Matrix 500mg/6mL 30 N9306604 Pre-Concentration of Hydrophilic Compounds 500mg/6mL 30 N9306598 Removal of Polar Compounds from Aqueous and Organic Matrix 500mg/6mL 30 N9306600 SPE Application Packs Ideal for extraction of known entities from a variety of matrices, our packs are expertly tailored to meet your application needs and are designed to support major EPA methods and applications. SPE Supra-Clean Application Packs Weight/Volume Qty/pack Part Numbers Extraction of PAH from Soil and Oil 1.5g/6mL 30 N9306609 Extraction of PAH from Soil and Oil (Glass Straight Column) 1.5g/6mL 30 N9306610 Extraction of PAH from Water Containing Humic Acids 1.5g/6mL 30 N9306608 Extraction of PCB from Oil 1g/3mL 50 N9306616 Extraction of Bisphenol A from Aqueous Matrix 1g/6mL 30 N9306613 Extraction of Oil and Grease from Aqueous Matrix-EPA 1664 1g/6mL 30 N9306611 Extraction of PCB from Oil 1g/6mL 30 N9306617 Extraction of SVOC from Water-EPA 525 1g/6mL 30 N9306618 Extraction of Basic Drugs from Biological Fluids 200mg/3mL 50 N9306605 Extraction of PAH from Water or Soil 4g/6mL 30 N9306606 Extraction of PAH from Water or Soil (Glass Straight Column) 4g/6mL 30 N9306607 Extraction of Oil and Grease from Aqueous Matrix-EPA 1664 500mg/3mL 50 N9306612 Extraction of Pesticides and Herbicides from Aqueous Matrix 500mg/6mL 50 N9306614 Extraction of Steroids from Biological Fluids 500mg/6mL 50 N9306615 www.perkinelmer.com/spe 5

Complete Consistency. Complete Confidence. Weight/Volume Qty/pack Part Number SPE Supra-Clean Cyano (CN-S) Column 500mg/3mL 50 N9306645 500mg/6mL 30 N9306644 SPE Supra-Clean Florisil (FL-S) Column 1g/6mL 30 N9306413 200mg/3mL 50 N9306511 2g/15mL 20 N9306514 2g/25mL 20 N9306515 2g/6mL 20 N9306513 500mg/3mL 50 N9306512 500mg/6mL 30 N9306494 SPE Supra-Clean Florisil (FL-S) Pesticide Grade Column 1g/6mL 30 N9306436 200mg/3mL 50 N9306516 2g/15mL 20 N9306443 2g/25mL 20 N9306447 2g/6mL 20 N9306470 500mg/3mL 50 N9306400 500mg/6mL 30 N9306517 SPE Supra-Clean Amino (NH2-S) Column 100mg/1mL 100 N9306410 100mg/3mL 50 N9306529 200mg/3mL 50 N9306530 500mg/3mL 50 N9306414 500mg/6mL 30 N9306531 50mg/1mL 50 N9306528 SPE Supra-Clean Polyamine (P6) Column 500mg/3mL 50 N9306518 500mg/6mL 30 N9306434 Weight/Volume Qty/pack Part Number SPE Supra-Clean 300Å C4 Column 100mg/1mL 100 N9306591 100mg/3mL 50 N9306592 200mg/3mL 50 N9306593 50mg/1mL 50 N9306590 SPE Supra-Clean C18 Column 100mg/1mL 100 N9306478 100mg/3mL 50 N9306523 1g/6mL 30 N9306422 200mg/3mL 50 N9306462 2g/15mL 20 N9306479 2g/25mL 20 N9306475 2g/6mL 20 N9306430 500mg/3mL 50 N9306438 500mg/6mL 30 N9306448 50mg/1mL 50 N9306476 200mg/6mL 30 N9306634 500mg/6mL 30 N9306640 500mg/3mL 50 N9306642 SPE Supra-Clean LCC Column 500mg/3mL 50 N9306643 500mg/6mL 30 N9306641 SPE Supra-Clean Phenyl (PH-S) Column 100mg/1mL 100 N9306524 100mg/3mL 50 N9306525 1g/6mL 30 N9306527 200mg/3mL 50 N9306490 500mg/3mL 50 N9306421 500mg/6mL 30 N9306526 50mg/1mL 50 N9306401 SPE Supra-Clean Silica (SI-S) Column 100mg/3mL 50 N9306532 1g/6mL 30 N9306404 200mg/3mL 50 N9306444 2g/15mL 20 N9306534 2g/25mL 20 N9306535 2g/6mL 20 N9306533 500mg/3mL 50 N9306402 500mg/6mL 30 N9306466 SPE Supra-Clean REC18 Column (full accessible surface) 100mg/1mL 100 N9306520 100mg/3mL 50 N9306455 1g/6mL 30 N9306491 200mg/3mL 50 N9306521 500mg/3mL 50 N9306522 500mg/6mL 30 N9306457 50mg/1mL 50 N9306519 200mg/1mL 30 N9306633 6

Weight/Volume Qty/pack Part Number Weight/Volume Qty/pack Part Number SPE Supra-Clean Strong Anion Exchange (SAX) Column 100mg/1mL 100 N9306471 100mg/3mL 50 N9306554 200mg/3mL 50 N9306482 500mg/3mL 50 N9306555 500mg/6mL 30 N9306556 50mg/1mL 50 N9306553 SPE Supra-Clean Strong Cation Exchange (SCX) Column 100mg/1mL 100 N9306432 100mg/3mL 50 N9306537 200mg/3mL 50 N9306538 500mg/3mL 50 N9306539 500mg/6mL 30 N9306540 50mg/1mL 50 N9306536 SPE Supra-Clean Weak Cation Exchange (WCX) Column 100mg/1mL 100 N9306545 100mg/3mL 50 N9306546 200mg/3mL 50 N9306547 500mg/3mL 50 N9306420 500mg/6mL 30 N9306407 50mg/1mL 50 N9306544 SPE Supra-Clean Mixed-Mode (MM1, MM2, MM3) Column 100mg/1mL 100 N9306542 (MM1) 100mg/3mL 50 N9306419 (MM1) 200mg/3mL 50 N9306543 (MM1) 500mg/3mL 50 N9306481 (MM1) 500mg/6mL 30 N9306416 (MM1) 50mg/1mL 50 N9306541 (MM1) 100mg/1mL 100 N9306549 (MM2) 100mg/3mL 50 N9306550 (MM2) 200mg/3mL 50 N9306551 (MM2) 500mg/3mL 50 N9306411 (MM2) 500mg/6mL 30 N9306552 (MM2) 50mg/1mL 50 N9306548 (MM2) 500mg/6mL 30 N9306649 (MM3) For more information or to experience the unparalleled consistency of PerkinElmer SPE solutions, please contact your sales representative, call 1-800-762-4000 or visit www.perkinelmer.com/spe. SPE Supra-Poly Extreme Capacity 1500 m 2 /g (XC) Column 100mg/1mL 50 N9306403 100mg/3mL 50 N9306440 1g/15mL 20 N9306503 200mg/3mL 50 N9306428 30mg/1mL 50 N9306441 500mg/6mL 30 N9306405 50mg/1mL 50 N9306500 60mg/1mL 50 N9306501 60mg/3mL 50 N9306502 200mg/6mL 30 N9306635 SPE Supra-Poly Extra Wide Particle 1200 m 2 /g (XWP) Column 100mg/1mL 50 N9306506 100mg/3mL 50 N9306508 1g/15mL 20 N9306510 200mg/3mL 50 N9306509 30mg/1mL 50 N9306504 500mg/6mL 30 N9306418 50mg/1mL 50 N9306427 60mg/1mL 50 N9306505 60mg/3mL 50 N9306507 SPE Supra-Poly ATH, ATL, AEV Polymer Column 200mg/6mL 50 N9306636 (ATH) 200mg/3mL 50 N9306638 (ATH) 100mg/3mL 50 N9306646 (ATH) 200mg/6mL 50 N9306637 (ATL) 200mg/3mL 50 N9306639 (ATL) 100mg/3mL 50 N9306647 (ATL) 100mg/3mL 50 N9306648 (AEV) SPE Clean Silica (SI-S) Cartridge (full accessible surface) 1300mg 50 N9306586 300mg 50 N9306584 700mg 50 N9306585 SPE Supra-Clean C18 Cartridge (full accessible surface) 1690mg 50 N9306589 390mg 50 N9306587 910mg 50 N9306588 www.perkinelmer.com/spe 7

At PerkinElmer, we understand that sample preparation is one of the most critical steps in the analytical process. Often accounting for 60% of your timetable, it has a fundamental impact on a wide range of operational parameters. Any errors within this process undermine the quality of your data at all subsequent stages of your analysis. Solid Phase Extraction helps avoid potential errors in sample preparation, reducing re-runs and dramatically increasing productivity. As one of the most cost-effective and flexible tools within the laboratory environment, SPE also provides efficient sample concentration and purification prior to many of today s most popular analytical techniques, including HPLC, LC/MS, GC and GC/MS. The right accessories, consumables, methods and application support are as integral to the success of your laboratory as your instrumentation. That s why we invest heavily in testing and validating our complete portfolio of solutions to ensure you receive accurate, repeatable results on time, every time. SPE columns are part of PerkinElmer s complete offering of analytical solutions an industry-leading portfolio that encompasses instruments, accessories, consumables, supplies, training and service. It s a breadth of capabilities that enables us to offer the ease and convenience of having a single supplier for all your needs at every stage of your workflow. So you can benefit from greater responsiveness, superior reliability, and dramatic cost savings. Couple SPE With Leading Instrumentation For Ultimate Laboratory Efficiency Clarus 680/580/480 GC Clarus SQ 8 GC/MS Flexar SQ 300 MS Flexar LC and UHPLC Our OneSource Laboratory Services division even takes it a step further. With more than 1,500 trained and certified field service engineers and service personnel around the world, OneSource offers the most comprehensive portfolio of professional laboratory services in the industry, including complete care programs for virtually every technology and manufacturer. So turn to PerkinElmer. For the experience. For the confidence. For the better. PerkinElmer, Inc. 940 Winter Street Waltham, MA 02451 USA P: (800) 762-4000 or (+1) 203-925-4602 www.perkinelmer.com For a complete listing of our global offices, visit www.perkinelmer.com/contactus Copyright 2011, PerkinElmer, Inc. All rights reserved. PerkinElmer is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners. 009795_01 Printed in USA