CATALOGUE NUMBERS. Pressure Reducing Valve (PRV)** Mains Supply. Cold Water Outlets

Similar documents
FM Mattsson. Pressure Balancing Thermostatic Mixing Valves FEATURES. - Different on the inside

The New Caroma TMV20

Pressure Balanced Thermostatic Mixers

In-line thermostatic mixing valves

ANTI-SCALD THERMOSTATIC MIXING VALVES PUTTING YOU IN CONTROL

FM Mattsson. Pressure Balancing Thermostatic Mixing Valves FEATURES. - Different on the inside

Brawa-Mix Thermostatic mixing valves

Owner s Guide and Installation Instructions Commercial Storage Tank

Thermostatic mixing valves with replaceable cartridge for centralized systems

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

Varsity Concealed Shower System

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide

Operation / Installation Manual

Owner s Guide and Installation Instructions Commercial Stainless Steel Storage Tank

Thermostatic mixing valves. Pegler Yorkshire

HERZ Regulating valve 4002

HERZ Differential Pressure Control Valve 4002

Owner s Guide and Installation Instructions Electric Domestic Water Heater

PULL-ON PEX PLUMBING SYSTEM

Installation Manual. HOTFLO (EHFA/EHFD) Series. Mains Pressure Vitreous Enamel Electric Storage Water Heater

Thermostatic mixing valves with interchangeable cartridges

AQUABLEND 1500 SOLAR THERMOSTATIC MIXING VALVE

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

aquablend thermostatic mixing valves

Automatic Temperature Controller (ATC)

HORNE 15 and 20 thermostatic mixing valve specification manual 2009

Thermostatic Bar Valves

INSTALLATION MANUAL Roof Mount Solar Hot Water System

Concealed Twin & Triple Thermostatic Shower Valve with Diverter. Installation & Operating Guide

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

Operation & Installation Manual

Series 20 Dual Check Backflow Preventers

Installation Instructions

Operation / Installation Manual

INTADUO THERMOSTATIC BATH/SHOWER MIXER

Owner s Guide and Installation Instructions

Dual Control Concealed & Exposed Thermostatic Shower Valve

Operation & Installation Manual

2016 CASH ACME CATALOG

Owner s Guide and Installation Instructions Electric Domestic Water Heater

Owner s Guide and Installation Instructions Electric Domestic Water Heater

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Installation Instructions Solar Controller Kit (Part Number AQ )

Owners Guide and Installation Instructions Commercial Air Sourced Heat Pump Water Heater

INSTALLATION MANUAL Ground Mount Solar Hot Water System

FM Mattsson. Pressure Balancing Thermostatic Mixing Valves FEATURES. - Different on the inside

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

Horne Engineering Ltd INSTALLATION, COMMISSIONING, OPERATING AND MAINTENANCE INSTRUCTIONS

Puro Mini Dual Control Shower Mixer PU90010CP

FIXATE mini exposed sequential thermostatic mixer shower

Installation, Operating and Maintenance Guide

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

RAISING THE BAR PROUDLY AUSTRALIAN MADE CUTTING EDGE INNOVATION DESIGNED WITH EXCELLENT SCALD PROTECTION BUILT IN SAFETY FEATURES.

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

Unvented Electric Water Heater 10/15 litre Undersink

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

All Valve Industries. General Product Overview. Distributed by All Valve Industries. Ph: Fax:

Kinetic. Logic. Astin. THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions. Please retain for future reference

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

Multipoint Technical Data

VITINO concentric thermostatic mini mixer shower

OWNER S GUIDE SEQUENTIAL THERMOSTATIC SHOWER VALVE. 150mm Inlet Pipe Centres. Shower Control. Handles and. may differ depending.

Dove Eco thermostatic bar mixer shower

Delphi dual control thermostatic mixer shower Installation and operating instructions

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

FOR INSTALLING AND USING

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

Operation / Installation Manual

Mimosa dual control mixer shower Installation and operating instructions

Operation / Installation Manual

Self-help Temperature Adjustment

Installation Instructions & Maintenance Guide 6 Refit Nuts (19) and tighten.

Own. Thermostatic Mixing Valve. Owner s Manual Containing. Installation, Commissioning and Maintenance guides. Lic. WMKA1895 AS SAI-Global.

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

Owner s Guide and Installation Instructions

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

SYSTEM MANUAL Description

Operation Installation Manual Rinnai Split Solar Hot Water Systems

Model T-45NL: Certified in compliance with ASSE 1017, 1069, 1070, and ANSI/NSF 61 PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING AND OPERATING!

DUOPEX WATER MANUAL mm WM WMKA021044

Rada Thermostatic Mixing Valves

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

Owner s Manual. Installation Details Owner s Information Warranty. Electric Storage Water Heaters

MERSEY sequential built-in thermostatic mixer shower Installation and operating instructions

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA

Operation / Installation Manual

MADDISON Dual control Thermostatic built-in mixer shower Installation and operating instructions

Version 1.0. Plumbers Handbook. Scan code for details & installation instructions

Owner s Guide and Installation Instructions

U.1347LS. Perrin & Rowe Kitchen Filtered Hot Water Dispensers 2 3/8" 5 1/2" 10" 6 1/2" 3 7/8" Ø1 7/8" 1 3/4" MAX Ø1 1/4" HOLE

THAMES concentric built-in thermostatic mini mixer shower

Telo Shower Mixing Valve TL10016CP

EDEN sequential exposed/built-in thermostatic mixer shower

INSTALLATION INSTRUCTIONS FOR MODELS 16NG50-6/16LP50-6, 16NG60-6/16LP60-6, 20NG50-6/20LP50-6, 20NG60-6/20LP60-6, 26NG50-6/26LP50-6, 26NG60-6/26LP60-6

Dart Eco concentric thermostatic mixer shower

Powerflow Unvented water heater

Owner s Guide and Installation Instructions

Owner s Guide and Installation Instructions

Transcription:

TRIO VALVE DESCRIPTION HYDROBOSS Trio Valves combine the mandatory functions of isolating valve and non-return valve for the installation of pressurized water heaters, with the additional protection of an integral strainer. No intermediary joins or fittings HYDROBOSS Trio Valves prevent the backflow of water from a water heater to the mains line. This serves the dual purpose of protecting the Less opportunity for leaks and mains supply from contamination and the loss of water that has already faults been heated. The isolating valve component, in the form of a ball valve, is useful as a means of controlling inlet water supply to unvented storage water heaters. The integrated strainer provides additional protection to the valve components and other valves and devices in the system. HYDROBOSS Trio Valves are available in 15 mm and 20mm configurations. CATALOGUE NUMBERS Model Trio Valve 15 mm Female BSP Trio Valve 20 mm Female BSP APPLICATION HYDROBOSS Trio Valves offer non-return and isolating functions with integrated strainer protection in a single valve. HYDROBOSS Trio Valves are suitable for use on water heater systems or wherever these three combined function are required. HYDROBOSS Trio Valve Installation (As part of an Inlet Control Group) Expansion Pressure Hydroboss Control Valve Limiting Valve Trio Valve (ECV)* (PLV) Inlet Controls to Hot Water System Cold Water Outlets Pressure Reducing Valve (PRV)** Mains Supply Catalogue Number BVNRIS501 BVNRIS701 FEATURES Integral construction of nonreturn valve, isolating valve and strainer One piece unit for tidy, simple and economical installation Tamper-proof non-return valve offers non-return protection for the life of the valve Separate service access for the strainer Quick cleaning and servicing of the strainer Ball valve construction of the isolating function Smooth and secure action when isolating water supply Dezincification resistant Meets Australian Standard for potable water supply Suitable for horizontal or vertical installation Valve designed to work effectively in either orientation Two year warranty Non Return Isolating Ball Valves * Drain line must comply with AS3500 ** Some states mandate pressure reduction at the mains supply to a domestic installation. Check with your local water authority to ensure compliance. AS 1357.1/2 Lic WMKA 21984 SAI Global Hydroboss is a Trademark owned by

TRIO VALVE MATERIALS Non Return Isolating Ball Valves Body: Ball Seat: Ball and Stem: O-ring: Check Valve: Strainer: Handle: PRODUCT SPECIFICATIONS Maximum Supply Pressure: Maximum Supply Temperature: (Peak Temperature) Continuous Service Temperature: Fluid Medium: Forged Brass PTFE Brass Nitrile Acetal Stainless Steel UV Stabilised Glassfiber Reinforced Nylon 1400kPa 93 C 65 C Water only L Model Length (L) Height (H) Connection (C) Trio Valve 15 mm Female BSP 105 72 Rp 1/2 Trio Valve 20 mm Female BSP 126 87 Rp 3/4 Hydroboss is a Trademark owned by

DUO VALVE DESCRIPTION HYDROBOSS Duo Valves combine the mandatory functions of isolating valve and non-return valves for the installation of pressurised water heaters. HYDROBOSS Due valves prevent the backflow of water from a water heater to the mains line. This serves the dual purpose of protecting the mains supply from contamination, and the loss of water that has already been heated. The isolating valve component is useful as a means of controlling inlet water supply to unvented storage water heaters. HYDROBOSS Duo valves are available in 15 mm and 20 mm configurations. CATALOGUE NUMBERS Model Duo Valve 15mm Female BSP Duo Valve 15mm Internal Flare Duo Valve 15mm Male Compression Duo Valve 20mm Female BSP Duo Valve 20mm Male Compression APPLICATION HYDROBOSS Duo Valves offer both non-return and isolating functions in a single valve. HYDROBOSS Duo Valves are suitable for use on water heater systems or wherever both non-return and isolating functions are required. HYDROBOSS Duo Valve Installation (As part of an Inlet Control Group) Expansion Control Valve (ECV)* Pressure Limiting Valve (PLV) Hydroboss Duo Valve Inlet Controls to Hot Water System Cold Water Outlets Pressure Reducing Valve (PRV)** Mains Supply * Drain line must comply with AS3500 ** Some states mandate pressure reduction at the mains supply to a domestic installation. Check with your local water authority to ensure compliance. Catalogue Number BVNI501 BVNIA501 BVNIC501 BVNI701 BVNIC701 FEATURES Integral construction of nonreturn valve and isolating valve One piece unit for tidy, simple and economical installation No intermediate joins or fittings Less opportunity for leaks and faults Tamper-proof non-return valve Offers non-return protection for the life of the valve Optional in-line strainer Smooth and secure action when isolating water supply Ball valve construction of the isolating function Dezincification resistant Meets Australian Standard for potable water supply Suitable for horizontal or vertical installation Valve designed to work effectively in either orientation Two year warranty Non Return Isolating Ball Valves AS 1357.1/2 Lic WMKA 21984 SAI Global Hydroboss is a Trademark owned by

DUO VALVE MATERIALS Non Return Isolating Ball Valves Body: Ball Seat: Ball and Stem: O-ring: Check Valve: Handle: PRODUCT SPECIFICATIONS Maximum Supply Pressure: Maximum Supply Temperature: (Peak Temperature) Continuous Service Temperature: Fluid Medium: Forged Brass PTFE Brass Nitrile Acetal UV Stabilised Glassfiber Reinforced Nylon 1400kPa 93 C 65 C Water only L Model Length (L) Height (H) Connection (C) Duo Valve 15mm Female Pipe Thread 81 52 Rp1/2 Duo Valve 15mm Internal Flare 95 52 DN15Cn Flared Duo Valve 15mm Male Compression 102 52 DN15Cn Duo Valve 20mm Female Pipe Thread 96 60 Rp3/4 Duo Valve 20mm Male Compression 107 60 DN20Cn Hydroboss is a Trademark owned by

TEMPERING VALVE SOLAR SIZES 15MM - 20MM PRODUCT CODES TV15S DN15 HYDROBOSS Temp Valve Solar TV20S DN20 HYDROBOSS Temp Valve Solar DESCRIPTION The HYDROBOSS Solar Tempering Valve has been especially designed for installation in residential or commercial premises fitted with a solar hot water system. Outlet temperature is factory set at 50 C and is fully adjustable from 40 C to 50 C. The HYDROBOSS Solar Tempering Valve incorporates an anti-scald thermal shut off system designed to shut the outlet water flow should the cold water supply be interrupted. OPERATION The outlet water temperature may be adjusted by removing the plastic cap and, with the special tool provided, turning the adjustment screw. A loss of the cold inlet supply results in a shut down of the outlet flow to minimise the risk of scalding. Flow control valves, such as taps, must be installed downstream of the tempering valve to allow on/off operation of fixtures, ie. showers etc. SPECIFICATION STATEMENT HYDROBOSS Solar Tempering Valve shall be approved to AS4032.2, incorporate hot and cold inlet check valves, and be installed in accordance with the manufacturer s instructions. FEATURES Easily retro fitted. Adjustable outlet temperature. High outlet flow rate. Anti-scald thermal shut off system. Direct connection to plumbing system. Built-in non-return valves on hot & cold inlets. Approved to AS4032.2. Two year warranty Insulation available on request APPLICATION HYDROBOSS Solar Tempering Valves are ideal for use in applications where a reduction of hot water temperature at specific fixtures is required. HYDROBOSS Solar Tempering Valves are suitable to use with continuous flow hot water systems. AS 4032.2 Lic WMKA 1593 SAI Global HYDROBOSS is a Trademark owned by

TEMPERING VALVE SOLAR SIZES 15MM - 20MM MATERIALS Body Seals Strainers Forged DR brass Viton 60 mesh, stainless steel 15mm Connections FITTINGS Union nuts Olives DR brass, BSP thread Copper TECHNICAL DATA Ratio of hot & cold supply pressures Ideal 1:1 Maximum 2:1 (either supply) 20mm Connections Inlet Pressure Variation 10% (from commissioning) Maximum hot & cold supply pressure Static 1600kPa Dynamic 500kPa Inlet temperature range Cold 5 C - 30 C Hot 60 C - 99 C Outlet temperature range Adjustable 40 C - 50 C Factory set 50 C max PERFORMANCE FLOW CHART- HYDROBOSS 15mm and 20mm VALVES Minimum temperature difference between hot inlet & tempered outlet 10 C Minimum flow rate 4 l/min DIMENSIONS A B TV15S 126 132 TV20S 151 193 * Dimensions are indicative only HYDROBOSS is a Trademark owned by

TEMPERING VALVE SIZES 15MM - 20MM PRODUCT CODES TV15 DN15 HYDROBOSS Temp Valve Standard TV20 DN20 HYDROBOSS Temp Valve Standard DESCRIPTION The HYDROBOSS Tempering Valve has been especially designed for installation in residential or commercial premises where the hot water supply to bathroom facilities must be maintained at a temperature appropriate for bathing. Outlet temperature is factory set at 50 C and is fully adjustable from 40 C to 50 C. The HYDROBOSS Tempering Valve incorporates an anti-scald thermal shut off system designed to shut the outlet water flow should the cold water supply be interrupted. OPERATION The outlet water temperature may be adjusted by removing the plastic cap and with the special tool provided, turning the adjustment screw. A loss of the cold inlet supply results in a shut down of the outlet flow to minimise the risk of scalding. Flow control valves, such as taps, must be installed downstream of the tempering valve to allow on/off operation of fixtures, ie. showers etc. SPECIFICATION STATEMENT HYDROBOSS Tempering Valve, shall be approved to AS4032.2, incorporate hot and cold inlet check valves, and be installed in accordance with the manufacturer s instructions. FEATURES Choice of inlet fittings. Easily retro fitted. Adjustable outlet temperature. High outlet flow rate. Anti-scald thermal shut off system. Direct connection to plumbing system. Built-in non-return valves on hot & cold inlets. Approved to AS4032.2. Two Year warranty Insulation available on request APPLICATION HYDROBOSS Tempering Valves are ideal for use in applications where a reduction of hot water temperature at specific fixtures is required. HYDROBOSS Tempering Valves are suitable to use with all mains pressure hot water storage units. AS 1357.1/2 Lic WMKA 21984 SAI Global HYDROBOSS is a Trademark owned by

TEMPERING VALVE SIZES 15MM - 20MM MATERIALS Body Seals Strainers Forged DR brass Viton 60 mesh, stainless steel 15mm Connections FITTINGS Union nuts Olives DR brass, BSP thread Copper TECHNICAL DATA Ratio of hot & cold supply pressures Ideal 1:1 Maximum 2:1 (either supply) 20mm Connections Inlet Pressure Variation 10% (from commissioning) Maximum hot & cold supply pressure Static 1600kPa Dynamic 500kPa Inlet temperature range Cold 5 C - 30 C Hot 60 C - 90 C Outlet temperature range Adjustable 40 C - 50 C Factory set 50 C max PERFORMANCE FLOW CHART- HYDROBOSS 15mm and 20mm VALVES Minimum temperature difference between hot inlet & tempered outlet 15 C Minimum flow rate 4/min DIMENSIONS A B TV15 120 132 TV20 151 193 * Dimensions are indicative only HYDROBOSS is a Trademark owned by