Fujitsu Condenser Model Number: AOU18RLXFZ, AOU18RLXFZH, AOU24RLXFZ, AOU24RLXFZH, AOU36RLXFZ, AOU36RLXFZ1, AOU48RLXFZ1.

Similar documents
Auto Louver : Up/Fown Auto Mode Minimum Heat Mode Economy Mode

EMI ENGINEERING SUBMITTAL

EMI ENGINEERING SUBMITTAL

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

SPECIFICATIONS FOR TENDER # SUPPLY OF DUCTLESS MINI-SPLIT AIR CONDITIONING SYSTEMS FOR WESTERN HEALTH


Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems

MINI-SPLIT HEATING AND COOLING SYSTEMS FOR RESIDENTIAL AND LIGHT COMMERCIAL APPLICATIONS

Mini-Split Air Conditioners and Heat Pumps

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

DESIGN & TECHNICAL MANUAL

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Mini-Split Air Conditioners and Heat Pumps for Residential and Light Commercial Applications

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

Samsung 360 Cassette, Single Zone, Split System

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

Submittal Data Sheet

DESIGN & TECHNICAL MANUAL

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Lennox Mini-Split Systems Year-Round Comfort and Performance

ductless mini-splits light commercial and multi-zone systems product catalog ALEGRIA ALEGRIA

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

SECTION VARIABLE REFRIGERANT VOLUME (VRV) HVAC SYSTEM

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Mini-Split Air Conditioners and Heat Pumps for Residential and Light Commercial Applications

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

SECTION VARIABLE REFRIGERANT FLOW SYSTEM

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

A single answer for multiple zones.

MINI-SPLIT STANDARD CONDITIONERS SINGLE ZONE. Available styles

Technical Product Guide

A single answer for multiple zones.

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

Geniuses at work. Residential Mini Splits

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Residential and Light Commercial Ductless Systems Catalog

Incremental Comfort Conditioners

RSG16**S1M. Split System Air Conditioner 16 SEER

TECHNICAL SPECIFICATIONS

MAC N-407 Air-Cooled Chiller

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

DUCTLESS MINI-SPLITS LIGHT COMMERCIAL AND MULTI-ZONE SYSTEMS PRODUCT CATALOG ALEGRIA ALEGRIA SERIES ALEGRIA

MACH N-407 Heat Pump Air-Cooled Chiller

TECHNICAL SPECIFICATIONS

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

NFZP Variable Refrigerant Flow Guide Specification

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

ART COOL MINI-SPLIT SINGLE ZONE. Neo Plasma. Outstanding air purification ART COOL. Customized good looks. Available styles and finishes

TECHNICAL SPECIFICATIONS

DESIGN & TECHNICAL MANUAL

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Model: Ceiling Cassette V 9k-24k

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Precise Temperature Control; Compact Footprint

Single - Zone Systems

Multi - Zone Systems. Specification and Performance. 208V-230V 18k-36k. Presents

2 shp 13 lc 1 36 t - 1 a

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

Specifications, Performance & Submittal

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

AIR COOLED PACKAGED CHILLER

duct-free air conditioning systems Art cool inverter flex multi-split

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

C. Samples for Initial Selection: For units with factory-applied color finishes.

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

InverterFlex SERIES InverterFlex Systems condition up to five rooms

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Condensing Units & Air Handlers

MAC-120HE-03 Air-Cooled Chiller

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

DESIGN & TECHNICAL MANUAL

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

Transcription:

HVAC Guide Specifications Mini-Split Multi-Zone Section 15700 Mechanical HVAC Evaporator Size Range: 7K 24K BTU Fujitsu Evaporator Model Number: ASU7RLF1, ASU9RLF1, ASU9RLS2, ASU12RLF1, ASU12RLS2, ASU15RLS2, ASU18RLF, ASU24RLF, ARU7RLF, ARU9RLF, ARU12RLF, ARU18RLF, ARU24RLF, AUU7RLF, AUU9RLF, AUU12RLF, AUU18RLF, AGU9RLF, AGU12RLF, AGU15RLF. Fujitsu Condenser Model Number: AOU18RLXFZ, AOU18RLXFZH, AOU24RLXFZ, AOU24RLXFZH, AOU36RLXFZ, AOU36RLXFZ1, AOU48RLXFZ1. Part 1 General 1-1 System Description: The air-conditioning evaporator system shall be a Fujitsu General RLF or RLF1 series mini-split system. The cassette shall consist of a ceiling mounted indoor cassette section. (AUU series) The wall mounted shall consist of a wall mounted indoor evaporator. (ASU series) The slim duct shall consist of a ducted installation type and installed horizontal or vertically. (ARU series) The floor mounted shall consist of a floor mountable evaporator. (AGU series) The evaporator will come with either wireless or wired remote controller depending on evaporator type. The evaporator shall connect with matching AOU inverter series condensing unit model of AOU18RLXFZ, AOU18RLXFZH, AOU24RLXFZ, AOU24RLXFZH, AOU36RLXFZ, AOU36RLXFZ1, or AOU48RLXFZ1 208-230/1/60 condensing unit. 1-2 Quality Assurance: 1) These units shall be listed by ETL and bear the ETL label. 2) Units shall be rated in accordance to ARI standard 210 and bear the ARI label. 3) Units shall be manufactured in a facility that has met ISO 9002 and ISO 14001 international standards. 4) A full charge of R-410A for a 66, 98, or 164 line set shall be provided in the condenser section. (Reference condenser installation manual for proper charging information.) 5) A dry air holding charge will be provided in the evaporator section. 6) System SEER will be between 14.7 21.5 depending on evaporator combination set up. Page 1 of 10

System Model Number Pre-Charge Amount Pre-Charge Length Max Length Additional Charge 18RLXFZ 4 lbs. 13.5 oz. 98 ft. 164 ft..21 oz. /ft. 18RLXFZH 4 lbs. 3 oz. 98 ft. 164 ft..21 oz. /ft. 24RLXFZ 4 lbs. 13.5 oz. 98 ft. 164 ft..21 oz./ft. 24RLXFZH 4 lbs. 14 oz. 98 ft. 230 ft..21 oz. /ft. 36RLXFZ 7 lbs. 4.5 oz. 164 ft. 230 ft..27 oz. /ft. 36RLXFZ (18+18) 7 lbs. 4.5 oz. 66 ft. 131 ft..27 oz. /ft. 48RLXFZ1 7 lbs. 10 oz. N/A* 377 ft. N/A* *See Installation Manual for proper charging procedure. Handling and Storage: 1) The wired remote or wireless remote shall be packaged inside the carton with the evaporator section. 2) Wireless remote if required, shall be shipped as a separate accessory item for ARU and/or AUU models. ASU & AGU models shall include a standard wireless remote controller. 3) Unit shall be handled and stored according to manufacturing specifications. Part 2 Warranty: 2-1 The units shall have a manufacturer s warranty on all parts for a period of five (5) years from date of installation. The compressor shall have a warranty of seven (7) years from the date of installation. If any should not function properly during this period, it shall be repaired or replaced at the discretion of the manufacturer. This warranty does not include labor. 2-2 Manufacturer shall have more than nine (9) years performance experience in the US market. Part 3 Performance: 3-1 Each system shall perform in accordance to the ratings shown on the chart below. Performance shall be based on the following ARI standards: Cooling Indoor 80 FDB, 67 FWB; Outdoor 95 FDB, 75 FWB Page 2 of 10

System Model Number Type Combination Seer Power Supply Outdoor Noise Level (db) (max) 18RLXFZ 18RLXFZH 24RLXFZ 24RLXFZH 36RLXFZ 36RLXFZ1 48RLXFZ1 Non-Ducted 9+9 18 Ducted 9+9 16 Mix 9+9 17 Non-Ducted 9+9 21.5 Ducted 9+9 19 Mix 9+9 20.3 Non-Ducted 9+7+7 18 Ducted 9+7+7 15.5 Mix 9+7+7 16.8 Non-Ducted 9+7+7 20 Ducted 9+7+7 18 Mix 9+7+7 19 Non-Ducted N/A 16 Ducted N/A 14.5 Mix N/A 15.3 Non-Ducted 9+9+9+9 18 Ducted 9+9+9+9 16 Mix 9+9+9+9 17 Non-Ducted N/A 14.7 Ducted N/A 17 Mix N/A 15.8 208/230/60/1 49 208/230/60/1 50 208/230/60/1 52 208/230/60/1 52 208/230/60/1 55 208/230/60/1 55 208/231/60/1 58 Page 3 of 10

Part 4 Products: 4-1 Indoor Unit: General: The indoor unit shall be factory assembled, wired and run tested. Contained within the unit shall be factory wiring, piping, control circuitry and fan motor. The unit shall have self diagnostic function, 3 minute time delay, an auto restart function and an emergency operation manual run switch. Indoor unit refrigeration piping shall be charged with a dry air holding charge instead of R-410a. Wall-Mount Cabinet: Depending on the evaporator type, the cabinet shall have a white finish smooth easy to clean surface with and indicator lights to verify functioning and troubleshooting. Return air shall enter through the top of the cabinet. There will be a factory supplied separate back plate (if applicable) for securely mounting the evaporator on the wall. a) Fan: Evaporator fan shall be direct drive DC motor. Fan shall be dynamically balanced and run with permanently lubricated bearings. A motorized 4-way air louver shall provide automatic changes in air direction to provide a more uniform pattern of air distribution for wall mounted evaporators. Indoor fan shall provide 4 speeds, High, Medium, Low, and Quiet. b) Filter: Unit shall include a factory supplied washable filter for return air. c) Coil: Evaporator shall be nonferrous construction with aluminum plate fins on copper tubing. All tubing shall be factory brazed and leak checked prior to packaging at the factory. Page 4 of 10

Electrical: Power requirement shall be 208-230/60/1 Indoor unit will not have any supplemental electric strip type heat. Control: This unit shall have a wired or wireless control to perform input function necessary for operation of unit. Unit will have a dry mode setting to help remove humidity. Wireless handheld control shall have controls for temperature and time set, master control, auto swing louver, start/stop, fan and timer. Temperature change shall be from 60 F-80 F in two (2) degree increments. Microprocessor located in the indoor unit shall have the capability to sense return air temperature, coil temperature and process the commands from the remote to operate the outdoor unit as required. Unit shall be capable of automatic restart when power is returned after a power outage. Control signal shall be sent between the indoor unit and outdoor unit on the same wiring delivering voltage to the indoor unit. Cassette Cabinet: Depending on the evaporator type, the cabinet shall have a white finish smooth easy to clean surface with and indicator lights to verify functioning and troubleshooting. Return air shall enter through the top of the cabinet. d) Fan: Evaporator fan shall be direct drive DC motor. Fan shall be dynamically balanced and run with permanently lubricated bearings. A motorized 4-way air louver shall provide automatic changes in air direction to provide a more uniform pattern of air distribution for wall mounted evaporators. Indoor fan shall provide 4 speeds, High, Medium, Low, and Quiet. e) Filter: Unit shall include a factory supplied washable filter for return air. Page 5 of 10

f) Coil: Evaporator shall be nonferrous construction with aluminum plate fins on copper tubing. All tubing shall be factory brazed and leak checked prior to packaging at the factory. Electrical: Power requirement shall be 208-230/60/1 Indoor unit will not have any supplemental electric strip type heat. Control: This unit shall have a wired or wireless control to perform input function necessary for operation of unit. Unit will have a dry mode setting to help remove humidity. Wireless handheld control shall have controls for temperature and time set, master control, auto swing louver, start/stop, fan and timer. Temperature change shall be from 60 F-80 F in two (2) degree increments. Microprocessor located in the indoor unit shall have the capability to sense return air temperature, coil temperature and process the commands from the remote to operate the outdoor unit as required. Unit shall be capable of automatic restart when power is returned after a power outage. Control signal shall be sent between the indoor unit and outdoor unit on the same wiring delivering voltage to the indoor unit. Slim Duct Cabinet: Depending on the evaporator type, the cabinet shall have a white finish smooth easy to clean surface with and indicator lights to verify functioning and troubleshooting. Return air shall enter through the top of the cabinet. g) Fan: Evaporator fan shall be direct drive DC motor. Page 6 of 10

Fan shall be dynamically balanced and run with permanently lubricated bearings. A motorized 4-way air louver shall provide automatic changes in air direction to provide a more uniform pattern of air distribution for wall mounted evaporators. Indoor fan shall provide 4 speeds, High, Medium, Low, and Quiet. h) Filter: Unit shall include a factory supplied washable filter for return air. i) Coil: Evaporator shall be nonferrous construction with aluminum plate fins on copper tubing. All tubing shall be factory brazed and leak checked prior to packaging at the factory. Electrical: Power requirement shall be 208-230/60/1 Indoor unit will not have any supplemental electric strip type heat. Control: This unit shall have a wired or wireless control to perform input function necessary for operation of unit. Unit will have a dry mode setting to help remove humidity. Wireless handheld control shall have controls for temperature and time set, master control, auto swing louver, start/stop, fan and timer. Temperature change shall be from 60 F-80 F in two (2) degree increments. Microprocessor located in the indoor unit shall have the capability to sense return air temperature, coil temperature and process the commands from the remote to operate the outdoor unit as required. Unit shall be capable of automatic restart when power is returned after a power outage. Control signal shall be sent between the indoor unit and outdoor unit on the same wiring delivering voltage to the indoor unit. Page 7 of 10

Floor Mount Cabinet: Depending on the evaporator type, the cabinet shall have a white finish smooth easy to clean surface with and indicator lights to verify functioning and troubleshooting. Return air shall enter through the top of the cabinet. j) Fan: Evaporator fan shall be direct drive DC motor. Fan shall be dynamically balanced and run with permanently lubricated bearings. A motorized 4-way air louver shall provide automatic changes in air direction to provide a more uniform pattern of air distribution for wall mounted evaporators. Indoor fan shall provide 4 speeds, High, Medium, Low, and Quiet. k) Filter: Unit shall include a factory supplied washable filter for return air. l) Coil: Evaporator shall be nonferrous construction with aluminum plate fins on copper tubing. All tubing shall be factory brazed and leak checked prior to packaging at the factory. Electrical: Power requirement shall be 208-230/60/1 Indoor unit will not have any supplemental electric strip type heat. Control: This unit shall have a wired or wireless control to perform input function necessary for operation of unit. Unit will have a dry mode setting to help remove humidity. Wireless handheld control shall have controls for temperature and time set, master control, auto swing louver, start/stop, fan and timer. Temperature change shall be from 60 F-80 F in two (2) degree increments. Page 8 of 10

Microprocessor located in the indoor unit shall have the capability to sense return air temperature, coil temperature and process the commands from the remote to operate the outdoor unit as required. Unit shall be capable of automatic restart when power is returned after a power outage. Control signal shall be sent between the indoor unit and outdoor unit on the same wiring delivering voltage to the indoor unit. 4-2 Outdoor Unit: General: The outdoor unit is designed specifically for the matching indoor unit. The unit is equipped with circuit board that interfaces with the indoor unit. Outdoor unit contains a high efficiency inverter type compressor. Unit is to be factory assembled, wired, piped and run tested prior to leaving the factory. a) Unit Cabinet: Cabinet will be constructed out of galvanized metal with a baked enamel finish. Fan guard will be louvered to prevent entrance of foreign objects. b) Fan: Unit will have a direct drive propeller type fan. Motor for fan will be DC voltage permanently lubricated and balanced prior to assembly. Unit will have a horizontal discharge air flow. c) Coil: Condenser coil shall be nonferrous construction with aluminum plate fin on copper tubing. Refrigerant flow leaving the condenser coil shall be controlled by a metering device. Compressor: Compressor shall be a rotary type or scroll type mounted in such a way to prevent noise and vibration transmission outside the cabinet. Page 9 of 10

Unit will be pre-charged with R410a refrigerant to accommodate a 66, 98, or 164 line set depending on condenser model without the addition or removal of refrigerant. Unit will be capable of a maximum 131, 164, 230, or 377 (depending on condenser model) (49 max height difference) line set without the need to trap, change line sizes or add oil to the system. Refer to Install Manual for each system s specific installation details. Electrical: The unit electrical requirements shall be 208-230/60/1. The outdoor unit shall be controlled by a microprocessor. Control voltage to and from the indoor unit shall occur on the same wiring delivering power. Page 10 of 10