HM-4201-RTCM High-Temp Real Time Clock Module

Similar documents
HM-4201-RTCM High-Temp Real Time Clock Module

M41T50 Serial Access Digital Input Real-Time Clock with Alarms

M41T81. Serial Access Real-Time Clock with Alarms

M41T81S. Serial Access Real-Time Clock with Alarms

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

Datasheet: K-22 LO Sensor

ECE 4510/5530 Microcontroller Applications Week 10

DS1486/DS1486P RAMified Watchdog Timekeeper

DS1486/DS1486P RAMified Watchdog Timekeepers

Cadence Design of clock/calendar using 240*8 bit RAM using Verilog HDL

RS485 MODBUS Module 8AI

HUM-M2 Humidity Sensor Module Description

DS1286 Watchdog Timekeeper

Series Digital Controller Instruction Sheet

1Hz,16Hz, S2 S3 S4 S5 S6 S7 S8 ALARM REGISTER COMPARATOR WEEK SECONDS MINUTES HOURS DAYS MONTHS YEARS /12 1 /24 1 /7 /28-1 /31

MSP100 Pressure Transducer

DS1386/DS1386P RAMified Watchdog Timekeeper

GPS Evaluation Kit EVA1037/1080

MSP100 Pressure Transducer

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

RF-KNX / TP-KNX MEDIA COUPLER CO KNX 002

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat

FlameGard 5 MSIR HART

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

LCP-6144A4EDRx. 10GBASE-SR SFP+ Optical Transceiver FEATURES. Description. Applications. RoHS compliant. Compliant to SFP+ Electrical MSA SFF-8431

ECO N DATE DESCRIPTION OF CHANGE CHG

Q-SMART MODBUS KIT. Modbus Protocol & Parameters. Cod EN rev.a ed.08/2018. Q-SMART Software Version AE17

Lennox Climatic 50 and BMS Modbus, Trend or BACnet.

DP86 Constant Voltage with Fitting

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

TSEV01S01C10 SPECIFICATIONS

FPS CL Burst Mode SFF BIDI EPON ONU TRANSCEIVER(20Km)

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

EXD-HP1/2 Stand-alone Superheat/Economizer Controller

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

RTD TEMPERATURE SENSING SYSTEM

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6130/6131 Series with SPI Communication

FCX-11AB5-3XX-XX 155Mbps BIDI SFP TRANSCEIVER(100Km)

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

FlameGard 5 UV/IR HART

Modbus RTU RS485 Manual

86BSD Digital Output

FIS30XXseries Gas sensor module SPECIFICATIONS

Sensor MSS100 Multi-Sonic

Stratos Optical HD/SD BNC to "ST" Video Media Converter (Transmitter)

Smart GPS Antenna A1035-D

OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement

For Raychem ACS-30 Controls Systems

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6120/6121 Series

MODEL 834M1 ACCELEROMETER

86BSD Digital Output

Series Temperature Controller Instruction Sheet

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

MPL3115A2 Sensor Toolbox User s Guide

LCP-10G3B4QDRx-G. 10GBASE-LR SFP+ Optical Transceiver FEATURES. Description. Applications. Performance. RoHS compliant

SMART dust sensor for air purifier Description SM-ND-02A SM-ND-02A is a dust sensor that detects the dust particle concentration in air by using optic

Automation System TROVIS 5400 Ventilation Controller TROVIS Mounting and Operating Instructions EB 5477 EN. Electronics from SAMSON

Dimmer Switch MH-DT411

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

1.5. System description of Bridge Navigation Watch Alarm System (BNWAS 3000)

Smartphone Application Development Guide for BatteryMole Bluetooth Battery Monitoring System for Automobiles (BMBT)

ENGINEERING SAMPLES PYRO-ELECTRIC IR-DETECTOR

Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH6100 Series ±4.0 %RH Accuracy. Datasheet

REPEATER FS5200R INSTRUCTION MANUAL

89BSD Digital Output

SPECIFICATION FOR DIGITAL WATCH MODULE- UNIVERSAL RECEPTION

EXD-SH1/2 Controller for EX/FX/CX with ModBus Communication Capability

EXD-SH1/2 Controller for EX/FX/CX with ModBus Communication Capability

AKSolutions Data Sheet April 2007 AK882X RF POWER MONITOR. Description: Features:

200 SERIES ADVANCED PHOTO/THERMAL/IR DETECTOR PRODUCT SPECIFICATION

AO Annunciator Module

Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH9000 Series ±1.7 %RH Accuracy. Datasheet

15203B 25203B 35203B Uniaxial Biaxia Triaxial

Addendum HART Communication with the X2200 UV Flame Detector 1.1 4/

VTI MODEL itc5000 HEAT TRACING CONTROL SYSTEM OPERATIONS MANUAL

Manual Supplement. Model Number: 8680-N2. Communications Protocol. Contents of this manual supplement include:

LCP-10G3B4HDR(T)-G. 10GBASE-LR Lite SFP+ Optical Transceiver. Description. Applications. Performance FEATURES. RoHS compliance

M7100 Pressure Transducer

SERVICE & SETUP MANUAL WATER HEATER ELECTRONIC CONTROLLER

Modbus TCP/IP Option Instruction Manual

User s Guide. CN606 / 612 AC Series & CN606 / 612 DC Series CONTRONAUTICS INCORPORATED. Table of Contents.

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

Z-Wave Network Inclusion/Exclusion/Reset

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

RSMFM-2R MULTIFUNCTIONAL

86BSD Digital Output

FieldServer Driver - Serial FS McQuay Microtech Open Protocol

User manual. ABB i-bus EIB. Zone Terminal MT/S Intelligent Installation System ABB STOTZ-KONTAKT

S3F8S28. Smoke Detector. Revision 0.00 February Samsung Electronics Co., Ltd. All rights reserved.

OWNER S MANUAL. Part Number P RF

Apex MediTech ALC109 ALARM SYSTEM

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

Standard SPECIFICATIONS FEATURES APPLICATIONS

M5800 Pressure Transducer with Rotatable Display

AN FXPS7xxx series pressure sensor self-test features. Document information

+ A B V B NO NC V COM PV PV

Transcription:

HM-4201-RTCM High-Temp Real Time Clock Module HM-4201-RTCM Product Description & Applications High Temp Real Time Clock/Calendar Module with Build-In 32.768KHz Crystal Oscillator. Timing, Calendar and Alarm functions can be set via I2C BUS. The entire HT RTC Module is fully operational from 2.7V to 3.6V. The Timing/Calendar function is operational down to 1.8V range. Features Applications Driven by Build-in High-Temp Crystal Oscillator at 32.768KHz Timing, Calendar and Alarm functions set via 12C BUS Timing: Hours, Min, Sec and Sub-sec Calendar: Day of the Wk, Day, Month and Year Software Alarm: Sec, Min, Hr, Day of the Wk, Day, Month Wide Operating Temp: -40 C to +200 C 2.7 Vdc to 3.6 Vdc operation Low Current Consumption: 100uA 512Hz Frequency Output for Calibration RoHs Compliant 8-Pin 1/2 DIP Hermetically Seal Package 4-Point crystal mount for Harsh Environment Applications Design to meet 3000kg shock & 36grm vibration ECCN: EAR99 COO: USA Performance Specifications Block Diagram Oil / Gas downhole tool Geophysical services High temperature industrial process control Extended temperature Military/Aerospace Avionics Engine control 1 of 7

Parameter Min Typ Max Units Condition Frequency Stabilities 1 Operating temperature range -20 C to +180 C (RTCM 1) -40 C to +200 C (RTCM 2) Continuous operating life 2000 hours Temperature Stability of internal Oscillator -100-150 +100 +150 ppm ppm -25 C to +180 C (RTCM 1) -40 C to +200 C (RTCM 2) Supply Voltage 2.970 3.3 3.630 VDC +/-10% Supply Current 100 ua at 25 C 512 Hz Frequency Output (FT) Digital Output (OUT) Output (FT and OUT can be set via the configuration register) 512 Hz Frequency Output(FT) feature provides an RF frequency source for calibration purpose Digital Output (OUT) feature is intended to use with alarm funtion for event triggering purpose This pin is an open drain output and requires external pull-up resistor Serial Interface Specification HM-4201-RTC1 has an I2C serial bus interface that provides access to the control and status registers and the user SRAM. The I2C serial bus interface is compatible with industrial standard I2C serial bus protocol using a bidirectional data signal (SDA) and a serial clock signal (SCL) for communication between the Master and the Slave devices. Our HM-4201-RTC1 device serves as a Slave unit. The Master unit, such as a microcontroller will initiate data transfers and provides the serial clock for both transmit and receive operations. Environmental Compliance Environmental Compliance Vibration-Sine 20g to 2kHz Sine MIL-STD-202 Method 204 Condition D Vibration-Random 20grms to 2kHz Random MIL-STD-202 Method 214 Condition I-F Shock 1000g, 0.5ms MIL-STD-202 Method 213 Condition E Seal Test Fine MIL-STD-883 Method 1014 Condition A2 Seal Test Gross MIL-STD-202 Method 112 Condition D Temperature Cycling 10 Cycles minimum MIL-STD-883 Method 1010 Condition B Acceleration 5000g Y1 axis MIL-STD-883 Method 2001 Condition A 2 of 7

Address Memory Description BIT 7 6 5 4 3 2 1 0 00h 0 10 seconds Seconds Section Name Range Seconds 0 to 59 01h 1 10 Minutes Minutes Minutes 0 to 59 02h 0 0 10 Hours Hours Hours 0 to 23 03h 0 0 0 0 0 Day RTC Day 1 to 7 04h 0 0 10 Date Date Date 1 to 31 05h 0 0 0 10 Month Month Month 1 to 12 06h 10 Year Year Year 0 to 99 07h Out 512 Hz Out 0 0 0 0 0 0 Output C N\A Control 08h 0 Alarm E 0 0 0 0 0 0 Alarm E N\A 09h Reserved - Do Not Use Reserved N\A 0Ah Reserved - Do Not Use Reserved N\A 0Bh AARS 0 0 0 0 Alarm 1 RTCM Fail Status Alarm N\A 0Ch Esec 10 Seconds Seconds Seconds 00 to 59 0Dh Emin 10 Minutes Minutes Minutes 00 to 59 0Eh Ehour 0 10 Hours Hours Hours 0 to 23 0Fh Edate 0 10 Date Date Alarm Date 1 to 31 10h Emonth 0 0 10 Month Month Month 1 to 12 11h Eday 0 0 0 0 Day Day 1 to 7 12h-18h Reserved - Do Not Use Reserved N\A 19h Initialization 0 0 0 0 0 0 0 Device Initialization 1Ah-3Eh Reserved - Do Not Use Reserved N\A 3Fh 0 0 0 0 0 0 0 Initialization Device Initialization Note 1: Unless otherwise specified, the state of the registers is not defined when power is first applied. Note 2: Unless otherwise specified, a 0 must be set to 0 Note 3: Unless otherwise specified, a 1 must be set to 1 Note 4: Writing to a reserved area could cause an undefined state of operation. Note 5: Device initialization is required after every power cycle. Table 1 Memory Map INT1 INT2 N\A N\A Information The slave address contains the 7-bit RTCM address, which is 1101000x. The x represents the direction bit read or write, for a read x=1 and for a write x=0. The contents of registers 0x00 thru 0x07 can be modified by performing a byte or page write. If performing a byte write, the address will increment to the following address after the write has been completed. When the address pointer reaches 0x07 it wraps around to location 0x00. If doing a page write the address will wrap around after reaching 0x07 to address 0x00. All registers above 0x07 can only be modified via a byte write operation. Accessing the registers for reading follows the same set of guidelines as writing to the registers. 3 of 7

Real Time Clock Address (0x00h thru 0x06h) The real time clock (RTC) registers contains the time and date information. This information is stored in a binary-coded decimal (BCD) format. The time and date information is initialized or updated by writing to the appropriate register after a power cycle. When reading the minutes register the MSB (bit 7) will always be a 1. When writing to this register, the MSB (bit 7) is a don t care, and can be written either as a 1 or 0. The day of the week (Day) register is a user defined register, which has a range from 1 to 7. This register will increment by one at midnight every day. The user can assign any day of the week to any number they choose, as long as the days of the week are in sequential order (i.e., if 1 equals Sunday, then 2 equals Monday and so on). The date, month and year registers automatically adjust for months with less than 31 days, and takes into account leap years. The only exception is the year 2100 the leap year will not be taken into effect. 0x00 Contains the BCD seconds and 10 seconds. The range is 00 to 59. 0x01 Contains the BCD minutes and 10 minutes. The range is 00 to 59. 0x02 Contains the BCD hours and 10 hours. The range is 00 to 23. 0x03 Contains the BCD day of the week. The range is 1 to 7. 0x04 Contains the BCD date and 10 date. The range is 1 to 31. 0x05 Contains the BCD month and 10 month. The range is 1 to 12. 0x06 Contains the BCD year and 10 year. The range is 0 to 99. The following example shows how to write the current time and date using either the byte write or page write method. Setting the time and date to: 10:02:36 AM Friday 03/15/13 (assuming Friday is day 6 of the week) Using the byte write method: (Write the following data to the corresponding register address) Name Data Transmit Seconds 0x00 0x36 ~00~36 Minutes 0x01 0x02 ~01~02 Hours 0x02 0x10 ~02~10 Day 0x03 0x06 ~03~06 Date 0x04 0x15 ~04~15 Month 0x05 0x03 ~05~03 Year 0x06 0x13 ~06~13 Using the page write method: (The bold leading zeros are the seconds register address) ~00~36~02~10~06~15~03~13 Control Address (0x07h thru 0x08h) The control register consists of register 0x07 and 0x08. 0x07 contains the FT/OUT (pin 7) pin output control. Enabling bit 6 of this register will enable the 512Hz frequency output, regardless of the state of bit 7. Disabling bit 6 will enable the use of the FT/OUT pin as a logic output. When using the logic output function, enabling bit 7 will cause a high logic state. Out (0x07 bit 7) 512Hz Out (0x07 bit 6) FT/OUT Pin Output x (don t care) 1 512 Hz Frequency 0 0 0 Logic 1 0 1 Logic Table 2 FT/OUT Pin Output 0x08 contains the alarm enable (AlarmE) bit. This bit must be enabled to use the alarm function of the RTCM. 4 of 7

Status Address (0x0Bh) The status register contains two status flags (RTCM fail and Alarm) and the auto alarm reset (AARS) bit. After a power cycle or when applying power for the first time, the RTCM Fail flag will be enabled. The RTCM Fail flag alerts the user that the RTCM has lost power. Writing a 0 to this bit will manually clear the RTCM Fail flag. When the RTCM alarm is triggered, the Alarm flag will enable. Writing a 0 to this bit will manually clear the Alarm flag. Both status flags can only be written to as a 0 to clear the flag. Writing a 1 to either of these bits is not a valid command. To automatically clear the RTCM Fail and the Alarm flags after a valid read of the Status register, enable the AARS bit. If a manual reset of the status flags is preferred, then disable the AARS bit. Alarm Address (0x0Ch thru 0x11h) The alarm works by comparing the RTC to the Alarm; if they match the alarm flag will be enabled. Bit 7 of the alarm registers contains the enable bit for the corresponding register. Enabling bit 7 will cause that register to be used in the comparison between the RTC and the Alarm. See table 3 for an explanation of when the alarm will trigger by using the enable bits. 0x0C Contains the BCD seconds and 10 seconds for the alarm. The range is 00 to 59. 0x0D Contains the BCD minutes and 10 minutes for the alarm. The range is 00 to 59. 0x0E Contains the BCD hours and 10 hours for the alarm. The range is 00 to 23. 0x0F Contains the BCD date and 10 date for the alarm. The range is 01 to 31. 0x10 Contains the BCD month and 10 month for the alarm. The range is 1 to 12. 0x11 Contains the BCD day of the week. The range is 1 to 7. Enable bits of the corresponding registers Esec Emin Ehour Edate Emonth Eday Alarm Triggered 1 0 0 0 0 0 When seconds match 0 1 0 0 0 0 When minutes match 0 0 1 0 0 0 When hours match 0 0 0 1 0 0 When the date matches 0 0 0 0 1 0 When the month matches 0 0 0 0 0 1 When the day of the week matches 1 1 0 0 0 0 When seconds and minutes match 1 1 1 0 0 0 When seconds, minutes and hours match 1 1 1 1 1 1 When seconds, minutes, hours, date, month and day of the week match 0 0 0 0 0 0 Alarm will not trigger Table 3 Alarm trigger table 5 of 7

Device Initialization Address (0x19h and 0x3Fh) The RTMC requires a device initialization after every power cycle to ensure proper internal triggering. It is recommended that the device initialization be the first priority after a power cycle. Follow the steps in order listed below to properly complete the device initialization. 1. Write 0x01 to address 0x3F 2. Write 0x80 to address 0x19 3. Write 0x00 to address 0x3F Application Notes This example will walk you through the following processes: 1) Device initialization 2) Setting the time a. The time will be set to 15:08:36 Friday 04/05/13 i. (assuming Friday is day 6 of the week) 3) Setting the alarm a. The alarm will be set to trigger every time minutes = 30 and seconds = 45. 4) Enabling the alarm 5) Enabling the alarm auto rest bit and in the same step resting the alarm and RTCM fail flags to 0 6) Enabling the 512Hz output 7) Read time 8) Read status register 9) Disable the 512Hz frequency output and sets the FT/OUT pin output to logic 1 The I2C slave address for accessing the RTCM is 0xD0 for a write and 0xD1 for a read. Operation # of bytes to read Address Data to send Comments Write N\A ~3F ~01 Device initialization Write N\A ~19 ~80 Device initialization Write N\A ~3F ~00 Device initialization Write N\A ~00 ~36~08~15~06~05~04~13 Sets the time and date information Write N\A ~0C ~C5 Enables and sets the alarm for seconds Write N\A ~0D ~B0 Enables and sets the alarm for minutes Write N\A ~08 ~40 Enables the alarm Write N\A ~0B ~82 Enables alarm auto rest and resets alarm and RTCM fail flags to 0 Write N\A ~07 ~C0 Enables the 512Hz frequency output on the FT/OUT pin output Read 7 ~00 N\A Reads the time and date Read 1 ~0B N\A Reads the status register Write N\A ~07 ~80 Disables the 512Hz frequency output and sets the FT/OUT pin output to logic 1 6 of 7

Package Outline Pin Function 1 Internal Crystal Oscillator Enable Hi 2 No Connection 3 No Connection 4 Ground 5 SDA 6 SCL 7 FT \ Out 8 V DD Power Supply Voltage Ordering Information HM - 420 1 - RTCM - 1 Product Family HM: Hi-Temp Module Package 13 x 13 mm Product Type RTCM: Hi-Temp Real Time Clock Module Operating Temperature 1: -20 C to +180 C 2: -40 C to +200 C Package Code 1: 8 pin configuration For Additional Information, Please Contact USA: Vectron International 267 Lowell Road, Unite 102, Hudson, NH 03051 Tel: 1.888.328.7661 Fax: 1.888.329.8328 Europe: Vectron International Landstrasse, D-74924 Neckarbischofsheim, Germany Tel: +49 (0) 3328.4784.17 Fax: +49 (0) 3328.4784.30 Asia: Vectron International 68 Yin Cheng Road (C), 22nd Floor One LuJiaZui Pudong, Shanghai 200120, China Tel: 86.21.6194.6886 Fax: 86.21.6194.6699 Disclaimer Vectron International reserves the right to make changes to the product(s) and or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Vectron International 267 Lowell Road, Unit 102,Hudson, NH 03051 Tel: 1-88-VECTRON-1 http://www.vectron.com Rev: (6/7//2016 JV) 7 of 7