D165-D160 SERIES HYDRAULIC HOSE CRIMPER OPERATORS MANUAL

Similar documents
UNIQUE USER FRIENDLY MICROMETER STYLE ADJUSTMENT

D165 SERIES Service Hose Crimpers

KH-80 HYDRAULIC CRIMPER OPERATORS MANUAL

D100S-T420 Portable Service Hose Crimpers

UNIQUE USER FRIENDLY MICROMETER STYLE ADJUSTMENT

D105M COMPONENT IDENTIFICATION

D100 SERIES HYDRAULIC HOSE CRIMPER OPERATORS MANUAL

CC150 General Production Hose Crimper

CC25 HYDRAULIC CRIMPER OPERATORS MANUAL

CC1000 Production / Industrial Hose Crimper

CC38 General Production Hose Crimper

CC650 Production / Industrial Hose Crimper

MC2000 OPERATING AND CALIBRATION INSTRUCTIONS

HH80C HYDRAULIC CRIMP TOOL

MC1000 / MC1001 MANUAL. Operating and Calibration Instructions

Hydraulic Crimping Head, PN

Hydraulic Crimping Head, PN 69069

12 Ton Hydraulic Crimping Head, PN

JUL 17 Rev C

Safety & Operating Manual

Hydraulic Crimping Heads and

DYNA-CRIMP* Hydraulic Crimping Head, PN 69099

OmniCrimp 21. Safety & Operating Manual

Hydraulic Crimping Head, PN

CT-930CH, CT-930LPCH and CT-940CH TABLE OF CONTENTS

MAR 10 Rev C

MC2501 OPERATING AND CALIBRATION INSTRUCTIONS

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

Hydraulic Crimping Systems

IDT-12-N Hydraulic Crimping Tool

ENVIRO-PAK. Operation and Maintenance Manual. Manufacturer of

Manual Pressure Pump Generators Standard Laboratory Models Operation and Seal Packing Instructions

20 TON AIR/MANUAL SHOP PRESS

MK-100 JCS Tile Saw TILE SAW OWNER S MANUAL & OPERATING INSTRUCTIONS SERIAL NUMBER:

TC 222 TIRE CHANGER SPARE PART LIST 01

CUTMASTER Strip Cutting Machine

ModulAir Air Dryer with External Purge Tank - Changeover from Bendix AD-IS for Peterbilt Installation. Air Dryer Mounting Bracket (Item 1)

C12-HHT / 12-HHT HAND HYDRAULIC CRIMPING TOOL INTRODUCTION

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

Dyna-Star HP, HF, 10:1 Pumps: 120# and 400# Drum Cover and Follower Plate

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

CONTENTS 1 INTRODUCTION 3 2 PRODUCT DESCRIPTION 4 3 GENERAL INFORMATION 5 4 INSTALLATION 6 5 USE 10 6 MAINTENANCE 12 REV.

OPERATOR'S MANUAL CD 400 / CD 500

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

4 TON HYDRAULIC FLOOR PRESS INSTRUCTION MANUEL

XC-18. NOTE: *Machine shown without Lift-Up Safety Guard. This guard is included with machine. Machine should not be operated without this guard.

WCPT-3 and WCPT-4. Effective Date: 2017 IMPORTANT INFORMATION READ BEFORE USE. Drop-in Display Cases

USER S OPERATING AND INSTRUCTION MANUAL

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

B.I.C.A Built-In Coffee Appliance

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

SEARAY LOW MOISTURE POLISHER/SCRUBBER OPERATING & MAINTENANCE

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

RK12ID Remote Dieless Crimping Tool

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2

FM-17DS & FM-20DS FLOOR MACHINES

The Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. "all the comforts of home" FEATURES SPECIFICATIONS INSTALLATION

100T Electric Shop Press

55-Gallon Dispenser Package

POLISHERS. MODELS SeaRay 133 OPERATING & MAINTENANCE

RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual

OPERATIONAL & MAINTENANCE MANUAL For SEM Model 0101 HD Crusher Serial Numbers: 1010 thru 1057

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

RK1240 and RK1240C 12-ton, Single-acting, Die-type Crimping Tools

FEB 15 Rev C

I NS T RUC T ION MODEL 4346 MIXER-GRINDER MODEL

Wheelbarrow Mixer Operations Manual

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

RK ton, Single-acting, Die-type Crimping Tool

C14-HHT / 14-HHT HAND HYDRAULIC CRIMPING TOOL INTRODUCTION

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

M O D E L G W T OPERATIONS MANUAL TABLE OF CONTENTS

SPECIFICATIONS FEATURES

Models A710 and A710S Grills. TOASTMASTER Models A710 and A710S Grills

OPERATOR'S MANUAL HD-400

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

FM-17HD & FM-20HD FLOOR MACHINES

Type 200HT Series Electrode Stabilization Ovens

KuriKrimp Crimpers & Accessories

Flood Pumper Plus. Water Transfer Machine. Operator and Parts Manual. Model No.: Rev. 00 (11-99)

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550

Owner s Manual READ AND SAVE THESE INSTRUCTIONS

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1

Burn Easy Installation Instructions LP or Natural Gas Fired Units. Cremator Setup:

REIMERS ELECTRA STEAM, INC. INSTRUCTION MANUAL JG & JJ MODELS

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

INSTALLATION INSTRUCTIONS

Decorative Low Profile Integrated Kit

690 and Power Fishing Systems

Multiple Washer Laundry Control System Pneumatic - Wall Mount - 1 Channel - Installation Guide

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

LARGE AREA VACUUM LAV-30

Parts and Service Manual

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE

INTELLI-VAC 14 INTELLI-VAC 18

Bag-In-A-Box Oil Pump System

IMAGE V. Parts and Service Manual

Transcription:

Page D65-D60 SERIES HYDRAULIC HOSE CRIMPER OPERATORS MANUAL

SAFETY PRECAUTIONS Page MODELS COVERED This manual is applicable to different variations of the D60 Series and D65 Series Crimpers. A Standard, Metric and DC micrometer is available on different models. Crimping, calibration and repair procedures are similar for all models. See specifi c instructions and parts breakdown for the model in question. SAFETY PRECAUTIONS READ INSTRUCTIONS AND IDENTIFY ALL COMPONENT PARTS BEFORE US- ING CRIMPER CRIMPER CAN PRODUCE 60 TONS OF FORCE. KEEP BOTH HANDS AWAY FROM PINCH POINTS CONSULT HOSE AND FITTING MANUFACTURER FOR CORRECT MACHINE SETTINGS AND CRIMP MEASUREMENTS ALWAYS WEAR EYE PROTECTION For Parts and Service, Contact: Custom Machining Services, Inc. Valparaiso, In 6383 (9) 6-68 Rev 06--009

D60 SERIES / D65 SPECIFICATIONS Page 3 Die Series-----------------------------------------------------------------------------------------------D00 Series Maximum Cylinder Force-----------------------------------------------------------------------------------60 Ton Maximum Hose Diameter ( Wire)------------------------------------------------------------------- / Inch Maximum Hose Diameter ( Wire)------------------------------------------------------------------- / Inch Maximum Hose Diameter (6 Wire)------------------------------------------------------------------------ Inch Crimper Depth - D65----------------------------------------------------------------------------------- Inches - D60 Series-------------------------------------------------------------------------- Inches Crimper Width - D65---------------------------------------------------------------------------------.5 Inches - D60 Series ------------------------------------------------------------------------- Inches Crimper Height - D65------------------------------------------------------------------------------.5 Inches - D60 Series----------------------------------------------------------------------3.5 Inches Weight - D65------------------------------------------------------------------------------------------------0 Lb - D60 Series----------------------------------------------------------------------------------------50 Lb Pump - D65--------------------------------------------------------------------------------------------------Electric - D60 Series------------------Pump Not included - Manual, Pneumatic or Electric Available) Pump HP- D65---------------------------------------------------------------------------------------- HP(0V) Reservoir Capacity - D65----------------------------------------------------------------------------------- Gal Oil Type-----------------------------------------------------------------------------------ISO Viscosity Grade 6 Electric Power Requirement - D65------------------------------------------------------------------------0V D65 Series Crimper D60 Series Crimper

COMPONENT IDENTIFICATION Page 0 VOLT VALPOWER HYDRAULIC PUMP ww 60 TON HYDRAULIC CYLINDER OPTIONAL WORK LIGHT POWER SWITCH REMOVABLE PUSHER RETRACTION STOP MICRO-CRIMP ADJUSTER AUTOMATIC STOP SWITCH D65 SERIES CRIMPER PNEUMATIC START/ STOP SWITCH CALIBRATION AD- JUSTMENT SCREW DIE STORAGE SHELF (OPTIONAL WITH SOME CRIMPERS DIES NOT INCLUDED) STANDARD COMPRESSION RING STANDARD DIE SET STANDARD PRESSURE PLATE D60 SERIES CRIMPER MANUAL, PNEUMATIC AND ELECTRIC POWER SOURCES ARE AVAILABLE FOR THE D60 SERIES

CRIMPER QUICK START GUIDE Page 5 FOLLOW THESE STEPS BEFORE USING THE CRIMPER FOR THE FIRST TIME Plug the D65 crimper directly into a 0 volt wall outlet. CAUTION: DO NOT RUN THE CRIMPER ON AN EXTENSION CORD AS LOW VOLTAGE CAN DAMAGE THE MOTOR. Oil level in the D65 pump should be -/ to inches below the fi ll plug. Check to be certain that the shipping plug in the pump reservoir has been replaced with the Oil Fill and Vent Plug shipped with the crimper. CALIBRATION CHECK PROCEDURE Place the Pressure Plate, any Die Set and the Compression Ring in the crimper bottom fl ange in the order shown. (A hose and fi tting are not required for a calibration check) Lubricate the Die Set as shown in Crimping Instructions on P 6. NOTE: FAILURE TO LUBRICATE THE DIE SET AND COMPRESSION CONE COULD RESULT IN THE DIE SET SEIZING IN THE COMPRESSION CONE. Slide the Pusher onto the stud on the hydraulic cylinder. Set the Micrometer at: 00 for the Standard Micrometer 0 for the Metric Micrometer 95 for the DC Micrometer Depress and hold the Start/Stop switch on the D65 Series or continue to apply pressure to the D60 Series until the Die Set is completely closed oil pressure has built up in the hydraulic cylinder. For the D65 Series: If the ram extends and shuts off the motor approximately second after the die fi ngers are completely closed and the pump builds pressure (The sound of the pump will change) the crimper is correctly calibrated. METRIC DC STANDARD For the D60 Series: If the white line is just visible as shown in the illustration after the dies are completely closed and pressure has built up in the hydraulic cylinder the crimper is correctly calibrated. If the above conditions are not met, the crimper must be recalibrated. See calibration instructions on P 7. D60 SERIES MICRO CRIMP SIGHT BUTTON

CRIMPING IINSRUCTIONS Page 6 Make certain that the cone base is clean prior to inserting the pressure plate. Seat the Pressure plate fi rmly in the cone base and lubricate the fl at surface. Lubricate the die fi ngers with the moly disulfi de grease furnished with the crimper at the points shown. Place the lubricated die set squarely on the pressure plate as shown. Align the fi tting in the die set according to the hose and fi tting manufacturer s recommendation. Place the Compression Cone over the die set and compress the die set by hand to hold the hose and fi tting in place. See micrometer setting example. Caution: If the notches on the die set are visible prior to starting a crimp, you must go to a larger die set. Failure to do so could result in damage or personal injury. Slide the Pusher onto the stud on the ram and press the start stop switch or apply pressure to the D60 Series. The crimper will shut off when the crimp cycle is complete. (The white indicator line will be visible on the D60 series) Check the fi nal crimp diameter to confi rm that it is within manufacturer s specifi cations. Micrometer Setting Example: With a 30mm die and the micrometer set at 3.0mm, the fi nal crimp diameter will be 33mm (30mm + 3mm)

CALIBRATION AND SPECIAL FEATURES Page 7 CALIBRATION INSTRUCTIONS Insert the Pressure Plate, any standard D00 Series die set and the Compression Cone in the crimper base in the order shown. Note: There should not be a fi tting in the die set when checking calibration. Set the Micro Crimp Adjuster as follows: 00 for Standard Micrometer 0 for Metric Micrometer 95 for DC Micrometer Slide the Pusher onto the stud of the hydraulic ram. Press and hold the start/stop switch until the crimper shuts off for the D65 or apply pressure to the D60 Sereis until the die set is completely closed and the white indicator on the Micro Sight button is just visible.. If the D65 motor shuts off in approximately second after the die set is fully closed or the white line on the Micro Sight button is just visible, the crimper is correctly calibrated. If the crimper requires recalibration, hold the micrometer barrel with a 5/6 inch open end wrench and rotate the stem either in or out with a 5/3 inch hex key wrench. Rotating the stem out of the barrel decrease the time required for the pump to shut off. Recheck calibration. SPECIAL FEATURES An easily removable Coupling Stop makes repetitive crimps faster by not having to visually align the fi tting before each crimp. The adjustable Retraction Stop limits ram retraction to only the amount required to remove the hose and coupling saving time on multiple crimps.

TROUBLESHOOTING Page 8 PROBLEM: CRIMPER WILL NOT RUN AT ALL The white rocker switch is also a circuit breaker. Check to see that the circuit breaker has not been tripped. Check the wall outlet. The crimper comes from the factory wired for a 5 volt single phase circuit. Use of extension cords or outlets with inadequate power can damage the motor. Do not run the crimper from a portable power source. Check the stop switch mounted to the switch bracket under the Micro-Crimp Adjuster. This is a normally closed switch and if it does not close the crimper will not operate. CAUTION: Do not operate the crimper with this switch jumpered as the pump will not shut off and the brackets can be damaged. Check the pneumatically actuated switch in the electrical box mounted on the motor. This switch controls power to the motor and is actuated with air pressure from the pendant switch bulb. PROBLEM: CRIMP DIAMETER TOO LARGE Incorrect setting of the Micro-Crimp Adjuster. Check crimp specifi cations. (NOTE: All published machine settings are approximate. To correct for slight variances, the gauge settings may need to be adjusted for the specifi c hose, fi tting and size combination). Incorrect die being used. Each die has a useable range of approximately 3mm (.0 in) above the closed diameter of the die. The closed diameter is the die size stamped on the die ring. Check crimper calibration and re-calibrate if required. Inadequate pump pressure. Check oil level in the pump. It should be -/ to inches below the fi ll plug. Replenish with ISO Viscosity Grade 6 hydraulic oil. Inadequate lubrication of the dies and compression ring causing the pump to work harder than normal to reach the required diameter. Use only the grease shipped with the machine or equivalent. Inadequate pressure being generated by the pump. This is most likely if the crimper can crimp the smaller size hoses and not the larger hoses. When correctly adjusted, the pump should generate approximately 0,000 psi. Do Not adjust pump to produce in excess of 0,000 psi as damage to components or personal injury may result. No pressure being generated by the pump. There should be a defi nite change in pitch of the pump as it cycles into high pressure mode and begins to work harder. PROBLEM: CRIMP DIAMETER TOO SMALL Incorrect setting of the Micro-Crimp Adjuster. Check crimp specifi cations. ( NOTE: All published machine settings are approximate. To correct for slight variances, the gauge settings may be adjusted for the specifi c hose, fi tting and size combination). Incorrect die being used (See die range under Crimp Diameter Too Large). Check crimp diameter and re-calibrate if necessary. PROBLEM: DIES STICKING IN COMPRESSION CONE Inadequate lubrication of the compression cone and die surfaces. Use only the grease shipped with the machine or equivalent.

COMPONENT IDENTIFICATION Page 9 3 7 9 6 0 5 8 7 8 6 3 0 5 3 9 Item 3 5 6 7 8 9 0 3 3 5 6 7 8 9 0 3 D65 Crimper Head Assembly (06) Part Number Description 09 60 Ton Cylinder / Top Flange 0 Strain Rod 059 Bottom Flange 038 7/8 Narrow Rim Washer 9099A85 7/8 - Hex Nut 0 Retraction Stop Rod KHA-6 Stop Rod Locking Handle 00 Micrometer Mount Assembly AI-008 Pusher Retaining Disc 953A6 3/8-6 x HSFHCS 0068 Standard Micrometer Assembly 089 DC Micrometer Assembly 0587 Metric Micrometer Assembly 0077 Micrometer Nut 0085 Pusher Less Magnets 0085-0 Pusher With Magnets 0 Pressure Plate 03 Compression Cone 009 Limit Switch Bracket 903 Switch Limit Switch 955A537 /-0 x / BHCS 0069 Limit Switch Guard 955A90 8-3 x / BHCS 95630A37 #6 Teflon Washer 08 Die Retaining Clip 95A6 6-3 x 3/8 SHCS Qty

COMPONENT IDENTIFICATION Page 0 3 5 0 9 3 6 5 8 6 7 0 9 7 8 9 0 0 3 5 6 D65 Crimper Assembly (0) Item Part Number Description Qty 030 D65 Base Plate 0633 Pump Assembly 3 9865A50 /-0 x 3/ HHCS 90A09 / Lock Washer 5 906A09 / Flat Washer 6 06 D65 Crimper Head Assembly 7 09 Crimper Head Mounting Bracket 8 9865A66 3/8-6 x / HHCS 9 90A03 3/8 Lock Washer 0 906A03 3/8 Flat Washer 6 9865A63 3/8-6 x 7/8 HHCS 956A03 3/8-6 Hex Nut 3 060 Front Handle Assembly 933A56 /-0 x 3/ HHFCS 5 0 Rear Handle Assembly 6 005 Crimper Head Brace 7 955A578 5/6-8 x / BHCS 8 955A585 5/6-8 x / BHCS 9 956A030 5/6-8 Hex Nut 0 90A030 5/6 Lock Washer 906A030 5/6 Flat Washer 60TA-06X08 5 Deg Swivel Fitting 3 05 D65 High Pressure /" Hose 60TA-08X08 5 Deg Swivel Fitting 5 0095 Coupling Stop Assembly 6 039 Pneumatic Pendant Switch

COMPONENT IDENTIFICATION Page 60 Ton Cylinder / Top Flange Assembly (09) Item Part Number Description Qty 058 60 Ton Body / Top Flange 0065 60 Ton Piston 3 7-950 7 Disogrin O-Ring 006 Piston End Cap 5 95A 3/8- x SHCS 6 6 00760_ 60 Ton Spring 7 00653 Spring Plug 8 F-POM-3.75X.00X0.375 3.75 x.00 x 0.375 Wear Ring 9 3500-000-0375 POLYPAK 3.50 x.00 x 0.375 Polypak 0 937A60 3/8 Copper Flat Washer 95A633 3/8-6 x / SHCS SH90-35 375 Ram Wiper 3 069 60 Ton Retaining Ring 8 9 0 3 7 3 8 6 5 5 D65 Micrometer Mount Assembly (00) Item Part Number Description Qty 0 Micrometer Suspension Flange 07 Micrometer Brace 3 05 Micrometer Base Bracket 953A9 8-3 x / HSFHCS 5 9896A5 3/6 Dia. x / Spring Pin 3

D65-D60 SERIES WARRANTY Page CustomCrimp No-Nonsense Warranty Statement All CustomCrimp Products are warranted to be free of defects in workmanship and materials for one year from the date of installation. This warranty ends when the product becomes unusable for reasons other than defects in workmanship or material. Any CustomCrimp Product proven to be defective in workmanship or material will be repaired or replaced at no charge. To obtain benefi ts of this warranty, fi rst, contact Warranty Repair Department at Custom Machining Services at (9) 6-68 and then deliver via prepaid transportation the complete hydraulic product to: ATTN: WARRANTY REPAIR DEPT. Custom Machining Services, Inc. 36 North Co. Rd 00 East Valparaiso IN 6383 If any product or part manufactured by CustomCrimp is found to be defective by CustomCrimp, at its option, CustomCrimp will either repair or replace the defective part or product and return via ground transportation, freight prepaid. Custom Crimp will not cover any incoming or outgoing freight charges for machines sold outside The United States. This warranty does not cover any product or part which is worn out, abused, altered, used for a purpose other than for which it was intended, or used in a manner which was inconsistent with any instructions regarding its use. Electric motors are separately warranted by their manufacturer under the conditions stated in their separate warranty.