HOLOPHANE. Vector Luminaire. Optimum visibility. Improved highway safety. Outstanding visibility in critical security applications HL /98

Similar documents
HOLOPHANE. Vector Luminaire. Optimum visibility. Improved highway safety. Outstanding visibility in critical security applications HL /98

REFRACTOPACK. Corrosion resistant construction allows this luminaire to be installed in corrosive and marine outdoor applications.

High Mast Series HMAO HMSC

POLESTAR II SERIES HL /01

SIGN AND BILLBOARD LIGHTING

Arlington. Full Cutoff. Utility Series

Full Cutoff. Utility Series

Choice of factory set distributions. Thermally set white polyester powder paint. Optional wet location listing

HL-2449_flg:8 pager 6/17/10 11:19 AM Page 1 Tear Drop LED Series

Predator LED. Floodlight Luminaires.

LED Evolution of a Classic

AERS. Automatic Energy Reduction System HID lamp control systems for maximum energy savings

HMAO LED. High Mast Series

Washington Series LED Innovative Tradition Continues

Prismatite 7300 HOLOPHANE. The Prismatite 7300 s rugged and compact

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09

Lantern Post Top. LED Series

Post Top Full Cutoff HID

LMV Series W Low Profile - Medium Base

PoleStar II HOLOPHANE

Lantern Post Top. LED Series

Petrolux III. PW Series Wet Locations

SECTION EXTERIOR LIGHTING

OUTDOOR LIGHTING. Features and Benefits O Distinctive, European style with a sleek design

Correctional Facility led Lighting

GranVille II LED. Evolution of a Classic Continues

Applications. Standard Materials

E THANOL AND B IODIESEL P LANT L IGHTING S OLUTIONS

Best Practices for Quality Lighting Renovation Projects

Intentional Uplighting for Unprecedented Uniformity. Phuzion PHS LED High Bay 1

HOLOPHANE. Enduratron

RE Luminaire HOLOPHANE

KING LUMINAIRE The K902 Centurion Series Decorative Area Luminaire

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS

Fluorescent High Bays THERMAL. Management. Performance Never Looked So Good HL /06

TunnelPass LED Tunnel and Underpass Luminaire

DMV Series W For Combustible Dusts

LED IMPORTANT SAFETY INSTRUCTIONS

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

N2MVF Series Compact Fluorescent

HOLOPHORMS. PrismGlo

ACP LED Series. FLoodlight Luminaires. ACP LED Floodlight Luminaires

SITE /ROADWAY ET/SET SERIES. Entablature Watt

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial

elevated ambient capability. in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems.

Champ-Pak TM Wall Pack & Floodlight Luminaires Hazardous and Non-Hazardous

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

120V 12V LED LAMPS. Proven LED performance, superior savings and a broad range of options for landscape lighting systems

Evolve LED Garage Light

HOLOPHANE Outdoor Lighting

LuxeScape Collection LED architectural post top and area/site luminaire. Invue

LIGHTING LIGHTING. Overhead Electric Distribution Standards INTRODUCTION

LHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy.

GE Evolve LED Flood & Spot Lighting EFM1

LED IMPORTANT SAFETY INSTRUCTIONS

Wallpackette III. Wallpackette III

EVLED201 36W Led Luminaire. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 14.85

SECTION INTERIOR AND EXTERIOR LIGHTING FIXTURES

GOVERNMENT AND HOMELAND SECURITY LIGHTING CAPABILITIES GUIDE

STYLISH SOLUTIONS FOR OUTDOOR AND INDOOR SPACES

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

What Powered by Design Pro LED Technology means to you!

VAPORGARD Incandescent Luminaires

Hazardous Area LED Light -Class 1 Div 2 Groups A, B, C, D and Class 2 Div 2 F,G - 4' 4 lamp

- Heat sink has been thermal tested and was developed to deliver the best heat dissipation ratio on the market.

ROAM DCM Control Specification Guideline Division 16520

BALLAST SOURCE EB- Electronic ballast BALLAST QUANTITY. 1-(1) 4-light ballast LAMP SPECIFICATIONS SPECIFICATIONS

Metroline LED architectural luminaire

A Guide to the Commercial Building Tax Deduction. Effective: January 1, 2006 to December 31, 2008 HL /07

TH1000MTBHSG MH Hi-Bay HSG

EVLPF Series Compact Fluorescent

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

EarthTronics products. About us. Where efficiency meets innovation. T5 & T8 Linear. Founded in 2007, EarthTronics, Inc. is a Michigan based

Champ-Pak Wall Pack Luminares

Lighting Solutions A DIFFERENT WAY OF LIGHT. A Different Way of Light 2018 Venture Lighting International

Beauty Introduction. Dura. Value LOW VOLTAGE LANDSCAPE LIGHTING

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Enclosure 4X

Highbay Linear LED Series Flat Profile Design

Navion LED Area, Site and Roadway Luminaire

Lighting Solutions. from a Leader in Light Source Technology

SECTION LIGHTING

LIGHTING DESIGN STANDARDS SECTION City of Maryland Heights ZONING CODE

Lighting Solutions from a Leader in Light Source Technology

American National Standard for Roadway and Area Lighting Equipment Elliptically Shaped, Enclosed Side-Mounted Luminaires

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

BIRMINGHAM TOWNSHIP CHESTER COUNTY, PENNSYLVANIA Subdivision and Land Development Ordinance No Dated 02/18/03

SECTION STREET LIGHTING AND TRAFFIC SIGNALS Replace this section with the following:

AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER IMPORTANT SAFETY INSTRUCTIONS

Industrial 100 Watt Ultraviolet LED Light Fixture - Paint Spray Booth Approved Nanometer

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

POINT HELIDECK LIGHTS PRL-LSM LED LOW SURFACE MOUNT LIGHT

Rating. Class I Div II

48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2

Performance & Versatility

Transcription:

Vector Luminaire Optimum visibility Improved highway safety Outstanding visibility in critical security applications HL-9 /98

Vector Meets AASHTO requirements High vertical illumination Up to : spacing ratios % fewer fixtures required compared to Cobra-heads Ul listed and CSA certified Offset lighting improves safety Unlike conventional cobra-head street lighting, the Vector lighting system poles can be located outside the AASHTO defined Clear Zone, eliminating the need for expensive break-away foundations and guard rails. Fewer poles with locations further from the roadway means fewer obstacles for a motorist to avoid. Improved visibility Visibility is improved when contrast between an object and its background is increased. The unique photometric distribution produced by Vector helps increase the contrast. Direct glare from the luminaire is reduced since the unit is out of the driver s line-ofsight. Economical Vector lighting systems are more economical than conventional lighting systems for a number of reasons: wider spacing between poles means fewer luminaires, poles, lamps and foundations are needed; pole top mounting eliminates expensive arms and reduces the pole cost; set back from the roadway eliminates the need for expensive break-away bases or guard rails; energy cost, relamping cost and maintenance cost are also reduced.

Highway/ raodway Prisons Storage areas Power plants Industrial Security areas Parking lots Rail yards Vector knuckle mount Vector yoke mount Holophane Mission Statement: Application versatility Due to its unique design, Vector produces great visibility to be sure intruders stay out and prisoners stay in. The vertical luminance provided by Vector is ideal for areas to be scrutinized with closed circuit TV. Industrial, storage areas and parking areas also benefit from Vector s good balance of horizontal and vertical illuminance. Easy maintenance The Vector luminaire is designed for quick and easy maintenance throughout the life of the lighting system. With stainless steel door latches, a plug-in starter, and a unitized electrical system, all maintenance from lamp change to ballast replacement is accomplished without any tools. This feature results in significant long-term savings. HOLOPHANE Meets AASHTO requirements The outstanding performance of the Vector system means the illuminanace level AND the uniformity requirements as defined by AASHTO and IES can be easily met. Provide lighting products and solutions, giving our customers the greatest value through superior: visibility energy efficiency reliability quality service

Vector vs. Cobra-head Typical roadway lighting comparison Vector Cobra-head Lamp W HPS W HPS Lumens,, Mounting height.9m (').9m (') Pole spacing 9.9m (') 9.9m (') Fixture setback.m (') Pole setback.m (').m (') Lighting results Average footcandles maintained.98 (. lux). (. lux) Maximum footcandles maintained. (. lux). (8.9 lux) Minimum footcandles maintained. (.9 lux). (. lux) Max. to min. uniformity 8.8: : Ave. to min. uniformity.:.9:

Photometric Data Isofootcandles Vector The Vector luminaire is equipped with an adjustable socket in order to optimize performance for various application parameters. The narrow, medium, and wide distributions help the lighting designer meet the lighting criteria with the fewest number of luminaires and poles... increasing motorist and maintenance safety, decreasing maintenance, energy, and installation cost. The following curves are based on a mounting height of.9m ('). Contact your Holophane representative or refer to CALA for photometric tests of Vector with other lamps. To convert isofootcandle curve values for mounting heights other than.9m (') use the following multiplying factors: Mounting height (meter/feet) Factor 9.m (').m (').8..9m (')..m (').9.m (')..m ('). 8.9m (')......................................................................... HOLOPHANE

Performance Specifications Vector The luminaire shall be Holophane catalog number HLA- for use with a watt lamp. It shall operate in outdoor environments when mounted on poles, parapets, walls and brackets. It shall consist of a die cast aluminum housing, a unitized electrical assembly, and pressed borosilicate prismatic glass refractor enclosed in a cast aluminum door frame. The luminaire shall be UL listed as Suitable for use in Wet Locations and Suitable for use in Ambients of C and CSA certified. A vertical and horizontal adjustable knuckle fitter for mm ("), mm (") or mm (") tenon mount (or a galvanized steel yoke) shall support the housing assembly in such a manner that the luminaire can be easily aimed at any appropriate angle. Two stainless steel door latches shall allow quick, easy, toolfree access to all internal components. The door shall hinge at the top and shall be removable from the housing without the use of tools. The luminaire shall be vibration tested and pass an accelerated fatigue test simulating -g peak acceleration for million cycles. All exposed hardware shall be stainless steel. Copper-free aluminum castings shall be protected against corrosion by alkaline cleaning, zinc phosphate pretreatment, and TGIC polyester powder paint with a minimum dry film thickness of. mils. Electrical assembly: All electrical control components shall be mounted on a unitized assembly which shall be completely removable without tools. Disconnect plugs shall be included with the unitized assembly so no wiring or rewiring will be required for maintenance. A terminal block shall be provided for wiring to the power line. The copper wound ballast shall be manufactured by the luminaire manufacturer and shall operate the watt lamp at line volts with the following operating characteristics: starting current less than operating current; primary lamp extinguishing voltage, volts; operating line current, amps; input wattage, watts; and have its power factor over 9%. It shall operate at a minimum ambient starting temperature of F and shall provide lamp wattage regulation of + % for line voltage of + %. The HPS starter shall be totally encapsulated with a material which electrically and thermally insulates all electronic components from lamp and ballast heat. The encapsulating material shall also provide mechanical protection for all electronic components to prevent damage to the components during installation, maintenance, replacement and general handling. The starter shall be replaceable without tools and shall include an electrical disconnect plug which mates to the appropriate ballast and socket leads. Optical assembly: The optical train shall consist of a prismatic pressed borosilicate glass refractor with smooth outer surface and a formed anodized aluminum reflector. It shall produce an IES Type, (II, III or IV),, (short, medium or long), non-cutoff distribution based on a / mounting height offset reference line. The nickel plated, lamp grip, porcelain enclosed, pulse rated socket shall prevent undue lamp vibration and backout. The socket shall be field adjustable to produce a narrow, medium, and wide lighting pattern (across roadway). ANSI lamp label: A self adhesive label shall be provided which identifies the lamp type and size. The label characteristics shall meet ANSI C standard. UL listed: The luminaire shall be UL listed Suitable for Wet Locations at C. Warranty: The electrical assembly shall be fully warranted for a period of five () years and the remainder of the luminaire shall be warranted for a period of two () years. Electrical characteristics: For complete electrical data, see tables of electrical characteristics in Holophane Ballast Handbook, publication HL-. The physical properties of the Holophane Vector luminaires represent typical average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations. They are supplied as a technical service and are subject to change without notice. Check your local Holophane sales representative to assure current information.

Ordering Data Vector How to construct a catalog number for Vector Luminaire Fixture type Example: HLA AHP B PS Fill in cat. no.: Step Catalog no. Description. Luminaire HLA Vector UL listed ºC wet location mm (") CSA certified Source and HP W HPS wattage HP W HPS AHP W, V HPS HP W HPS HP W HPS RHP W HPS, Mag. reg. ballast HP W HPS RHP W HPS, Mag. reg. ballast MH W MH and MV MH W MH and MV MH W MH and MV. Voltage volt 8 volt volt volt volt (Canada) 8 MT 8 volt Multi-tap for V through V (USA),, V (Canada) (N.A. with RHP and RHP). Finish B Dark bronze G Grey. Mounting Knuckle mount for mm (") tenon thru mm (") dia. Knuckle mount for mm (") tenon thru mm (") dia. Yoke mount. Options PS Protected starter R Twist lock photocontrol receptacle Accessories (Ships separately) F Single fuse kit F Double fuse kit Lamp Appropriate HID lamp supplied How to construct a catalog number for Vector poles Poles meeting AASHTO design specifications Pole material Pole base Number of and shape type luminaires S RT: Steel, round tapered Anchor bolts, for knuckle mount A RT: Aluminum, round tapered Y for yoke mount Knuckle mount at mm (") mm (") SPRT J / mm (") Pole finish Pole height ft. Luminaire P-Prime painted steel Aluminum:.m ('),.m ('), 9.m ('), catalog no. G-Galvanized steel.m ('),.89m (9') From above L-Satin aluminum Steel:.m ('),.m ('), 9.m ('),.m ('),.89m (9'),.m (').m (') Optional Mounting Brackets: See Mounting Accessories Brochure #HL-9 Order number: Job name: Yoke mount at Weight:.8 kg ( lbs) 8. kg ( lbs) EPA:.m (. sq. ft.) HOLOPHANE

Holophane Corporation, Oakwood Ave., Newark, OH / Holophane Canada, Inc. 9 Walker Drive, Unit #, Brampton, ON Canada LT Z / Holophane Europe Limited, Bond Ave., Milton Keynes MK JG, England / Unique Lighting Solutions, / Heathcote Road, Moorebank, NSW Australia/ Holophane, S.A. de C.V., Apartado Postal No. 98, Naucalpan de Juarez, Edo. de Mexico HL-9 /98 Copyright Holophane Corporation 998 Contact your local Holophane sales representative for application assistance, and computer-aided design and cost studies. For information on other Holophane products and systems, call the Customer Service Center at --9. In Canada call 9-9- or fax 9-9-99. Limited Warranty and Limitation of Liability Refer to the Holophane limited material warranty and limitation of liability on this product, which are published in the Terms and Conditions section of the current price schedule, and is available from our local Holophane sales representative. Printed in USA