BOBINE ANTIDEFLAGANTI (ATEX) ISTRUZIONI EXPLOSION PROOF COILS (ATEX) - INSTRUCTIONS

Similar documents
Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

INSTRUCTION MANUAL (ATEX / IECEx)

Certificate of Compliance

Beamex Calibration White Paper. Calibration in hazardous areas

Dual certification! Air handling units for potentially explosive atmospheres

Inductive slot sensor

Beamex. Calibration White Paper. Calibration in hazardous areas

Guide for hazardous areas

Certificate of Compliance

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

UL HAZARDOUS LOCATIONS SERVICES

manual addendum DELPHI Ex

Technical Data. Dimensions

Manual Power relay SR853

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. Dimensions

EU DECLARATION OF CONFORMITY

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

OPTIBAR DP 7060 Supplementary Instructions

Approved by: Document no.: EGT

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

IECEx Certificate of Conformity

Flameproof Manual Call Points Series MCP

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

EXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN ZONES 1,21 & 2,22 KDB 15ATEX0049X NEW

Electrical Installations Design, Selection, Erection and Inspection

PEPPERL+FUCHS GmbH

Switches compliant with ATEX directive

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

Intrinsically Safe Solutions

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

INSTRUCTION & SERVICE MANUAL

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Overview of Hazardous Locations as They Relate to Solenoid Valves

OPTIWAVE X500 Supplementary Instructions

Operating Instructions

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

ARGENTA ATEX For potentially explosive atmospheres. ARGENTA ATEX Technical Specifications Wall-mounting cabinets. ARGENTA ATEX Certifications

standards: standards:

ATEX, NOMENCLATURE AND CODING

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

ExPolar Heating System

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Smart encoders & actuators

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

Flameproof Manual Call Points

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

OPTIBAR P 1010/2010 C Supplementary instructions

Technical Data. Dimensions

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

Certificate of Compliance

ATEX, NOMENCLATURE AND CODING

Explosion Proof Manual Call Points Series MCP

Fixed Gas Detection System/Meridian CERTIFICATION

S T R I T T & P R I E B E I N C.

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Safety instructions VEGABAR 81, 82, 83, 86, 87

USER GUIDE EXPLOSION-PROOF TELEPHONES ATEX GASES AND DUSTS TYPE 227A1 IM2 FOR GROUP I MINING II 2GD FOR GROUP IIC AND IIIC GASES AND DUSTS

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Illumination unit For sight glass level indicator Model LGI

Certification Supplement Manual

INSTRUCTION MANUAL (ATEX / IECEx)

IECEx Certificate of Conformity

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

TYPE APPROVAL CERTIFICATE

ATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas

Dräger Flame 2100 Flame Detection

Immersion heating type IN 16.. PTB 99 ATEX 1009 U. May thuba Ltd. CH-4015 Basle Telefon Telefax

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

IECEx Certificate of Conformity

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

ATM Lighting sp. z o.o

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

ATM Lighting sp. z o.o

ELECTRICAL EX EQUIPMENT

Dräger Flame 2500 (IR3) Flame Detection

Certificate of Compliance

Explosion-proof Immersion Heater Type D-8660

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

Ex LED light fittings

Transcription:

BOBINE ANTIDEFLAGANTI (ATEX) ISTRUZIONI EXPLOSION PROOF COILS (ATEX) - INSTRUCTIONS Bobine delle serie EEXM Questi prodotti vengono realizzati dalla AMISCO S.p.A. Le pagine seguenti sono le istruzioni realizzate dalla AMISCO stessa. Questa è l equivalenza tra i codici della Metal Work ed i codici AMISCO, stampigliati sulle bobine: Codice Metal Work Codice AMISCO 02276069 3009MD024W3 022760801 _ 3009MA024W2 022760802 _ 3009MA110W2 022760803 _ 3009MA230W2 Coils series EEXM Products are made by AMISCO S.p.A. Following pages are the instruction made by Amisco itself This is the equivalence between Metal Work codes and AMISCO codes, printed on the coils. Metal Work Code AMISCO code 02276069 3009MD024W3 022760801 _ 3009MA024W2 022760802 _ 3009MA110W2 022760803 _ 3009MA230W2 Documento AT90 04/2016

Coil Type 3009M INSTRUCTIONS 1/4

MANUFACTURER NAME: AMISCO S.p.A. ADDRESS: via Piaggio, 70 Paderno D. MI ITALY TYPE: 3009M N N.B.: 0722 GROUP: II CATEGORY: 2G and 2D GAS AND COMBUSTIBLE DUST ATMOSPHERE EQUIPMENT EXPLOSION PROTECTION FOR: - GAS ATMOSPHERE Encapsulation m, level mb - COMBUSTIBLE DUST Encapsulation md, level mbd CERTIFICATE NUMBER: TÜV IT 13 ATEX 030 VOLTAGE TOLERANCE: ±10% DUTY CYCLE: 100% ED AMBIENT TEMPERATURE: 50 C +50 C ELECTRICAL DATA: DC solenoids Coil Vn f I P Temperature Type Code [ V ] [ Hz ] [ A ] [ W ] Class 3009M 3009MD006W3 6-0.510 3 T5 3009M 3009MD012W3 12-0.250 3 T5 3009M 3009MD024W3 24-0.125 3 T5 3009M 3009MD048W3 48-0.063 3 T5 3009M 3009MD006W4 6-0.640 3.8 T4 3009M 3009MD012W4 12-0.320 3.8 T4 3009M 3009MD024W4 24-0.160 3.8 T4 3009M 3009MD048W4 48-0.080 3.8 T4 AC solenoids Coil Vn f I P Temperature Type Code [ V ] [ Hz ] [ A ] [ VA ] Class 3009M 3009MA012W2 12 50/60 0.2700 3.2 T5 3009M 3009MA024W2 24 50/60 0.1330 3.2 T5 3009M 3009MA048W2 48 50/60 0.0670 3.2 T5 3009M 3009MA100W2 100 50/60 0.0320 3.2 T5 3009M 3009MA110W2 110 50/60 0.0290 3.2 T5 3009M 3009MA115W2 115 50/60 0.0280 3.2 T5 3009M 3009MA120W2 120 50/60 0.0270 3.2 T5 3009M 3009MA220W2 220 50/60 0.0146 3.2 T5 3009M 3009MA230W2 230 50/60 0.0140 3.2 T5 3009M 3009MA240W2 240 50/60 0.0134 3.2 T5 2/4

NOMINAL VOLTAGE TEMPERATURE CLASS WEEK AND YEAR OF PRODUCTION YELLOW-GREEN CABLE FOR EARTHING CONNECTION XXXV XX TX WW/YY BROWN EARTHING ADDITIONAL CONNECTION BLUE YELLOW GREEN The coil 3009M Exm is developed to fit Amisco operators. If a different operator is used, make sure that the coil powered with nominal voltage does not show a power consumption exceeding the values mentioned above. In any case, before giving its approval, Amisco has to carry out consumption and thermic tests on the operator specimen; on the contrary these tests will be conducted by the Client himself who has to inform Amisco about the results obtained. In this case the Client will also be responsible for eventual malfunctionings incurred by using non-tested operators. Week and year of production of the complete coil are printed on the upper side of the solenoid, as showed in the above drawing. The output cable of the solenoid consists of a brown colored lead, of a blue one and of a yellowgreen one. The brown and blue leads are the coil power supply while the yellow-green one, that is connected to all the conductive accessible parts of the coil, is the earth connecting. The coil has also an additional external connecting unit for the earth connection or for the equipotential bonding connection. INFORMATION FOR USE Electrostatic charges product, clean only with wet cloths or antistatic products. The coil is NOT a resetting device. When a failure occurs and the internal thermal protection break off, the coil is no longer functioning. The electrical connection between solenoid and electric installation has to be performed in compliance with EN 60079-18 for gas and EN 60079-31 for dusts respectively. The additional external connecting unit, if utilized, must be connected with a conductor with a cross-sectional area of at least 0.75mm 2. 3/4

Definitions and Symbols Our Marking Where: II 2G Ex mb IIC Tx Gb II 2D Ex tb IIIC Tx IP66 Db : Specific marking of explosion protection. II: Group II - Electrical apparatus for places with a potentially explosive atmosphere, other than mines susceptible to fire damp. 2: Category 2 - see the board below. G: Explosive gas atmospheres. D: Explosive atmosphere in the presence of combustible dust. Ex: The symbol Ex which indicates that the electrical apparatus corresponds to one of the protection type (EN 60079 0). mb: Type of protection for gas encapsulation m, level mb. tb: Type of protection for explosive dust atmospheres protection by enclosure. IIC: Electrical equipment of Group II is subdivided according to the nature of the explosive gas atmospheres IIC, a typical gas is hydrogen. IIIC: Electrical equipment of Group III is subdivided according to the nature of the explosive dust atmospheres IIIC, conductive dust. Tx: Temperature class: T4 or T5. Gb: Equipment protection level [EPL] for explosive gas atmospheres. Db: Equipment protection level [EPL] for explosive dust atmospheres. IP66: The degrees of protection provided by an enclosure against, ingress of solid foreign objects, dust (first number) and water (second number). Zone Category Description 1 and 2 2G Equipment in this category is intended for use in areas in witch explosive atmospheres caused by air/gas mixture are likely to occur. 21 and 22 2D Equipment in this category is intended for use in areas in witch explosive atmospheres caused by air/dust mistures are likely to occur. Paderno Dugnano, March 01, 2013 Ing. Elio Mantovani Persona Autorizzata 4/4