PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

Similar documents
PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

PelletVent Pro horizontal Kit. PelletVent Pro. PelletVent Pro Vertical Kit - Cathedral. PelletVent Pro Pellet Chimney

PelletVent Multi-fuel venting system. UL 641.

Venting System For Pellet and Corn Stoves. PelletVent Pro. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

CVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636.

Bring In the Fresh Air

DuraPlus HTC. All-fuel, double-wall chimney system. ULC S629.

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

Easy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation

BDM Direct Vent systems are for use with direct vent gas fired appliances.

PelletVent Pro. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

Pellet Stove. Flex Pipe. Appliance Connector

Installation Instructions. Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES

5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION

Installation Instructions. Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro

DirectVent Pro CVS. Unitized, co-axial venting system for direct vent gas or propane stoves, and fireplaces.

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

All-fuel, double-wall chimney system. UL 103 HT, UL 103, and ULC S604.

SUBJECT: SELKIRK MODEL DT DIRECT VENT SYSTEM FOR PELLET & CORN FIRED APPLIANCES / TERMINATION CLEARANCES TO OPENINGS IN BUILDINGS

VP Pellet Pipe. For pellet burning stoves. FEATURES

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

Venting. Vent Material. Approved Venting Accessories Simpson Dura-Vent DV unless otherwise specified. Wall Thickness

Secure Pellet. Venting for Biofuel Appliances (US) (Canada)

Installation & Maintenance Instructions

Ventis Direct Vent. Installation Instructions

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

PelletVent. Factory-Built Chimney Relining. Installation Instructions. PelletVent Pro (PVP)

VENT SYSTEM COMPONENTS

DuraTech. Installation Instructions. Combustion Air System

CHIMNEYS AND VENTS CHAPTER 8

ORTAL Power Vent System Manual Table of Contents

Gas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10

Ultimate Pellet Pipe

CHAPTER 8 CHIMNEYS AND VENTS

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

Installation Instructions

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

Type B Gas Vent. Installation Instructions

CHAPTER 8 CHIMNEYS AND VENTS

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual

Mitchell Metal Products, Inc.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual.

DURAVENT POLYPRO VENTING PRODUCTS

Direct Vent System. for PELLET STOVES FEATURES. Includes all Selkirk Model VP Pellet Pipe and Direct-Temp components needed to complete a system

PolyPro: For Venting Condensing Appliances Environmentally Safe Alternative Lower Over-All Cost Than PVC Engineered Terminations Fast, Easy To Install

Pellet Vent INSTALLATION INSTRUCTIONS

SL-VENT (oil and gas vent) For use with oil or gas fired appliances. Listed to ULC-609 and UL-641. Available in 5, 6, 7 and 8 I. D.

Shasta Vent Inc All-Fuel HT Chimney Installation Instructions

Installation and Maintenance Instructions

Saf-T Vent SC Plus/SC 316

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

Technical and Dimensional Data. Saf-T Vent SC Plus

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

DT-M Direct-Temp for Multi Fuel L-Vent / Vent System for Pellet, Corn and other Bio-Fuel Burning Appliances

INSTALLATION INSTRUCTIONS

Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR SV4.5RR4 PIPE REDUCER AND ALL ASSOCIATED SV4

P P Gas Fireplace. P See Thru

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

2012 INTERNATIONAL FUEL GAS CODE VENTS

ULC S636 System. PolyPro. PolyPro Flex. Terminations

EXCELPellet FACTORY BUILT PELLET CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS

VERTICAL POWER VENT KIT

FasNSeal. Installation Instructions

ZC Kit AGP Pellet Insert

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

Vertical Termination Part No: 3CGRVT 16 7/8" 18 Vent Pipe Extension Part No: 3CG18 9 7/8" Wall Hanger Part No: 3CGWH 7 7/8" 7 3/8"

St. Croix Greenfield Installation Manual

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

MODEL CF CEILING SUPPORTED CHIMNEY

Twin Wall Installation Instructions And Maintenance Guide

EXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE

ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution.

Pellet Vent INSTALLATION INSTRUCTIONS

flexible venting simply perfect cost efficient convenient durable Est FREEDOM VENTING FLEX

Advanced Venting Systems

INSTALLATION INSTRUCTIONS

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

INSTALLATION AND MAINTENANCE INSTRUCTIONS. 1700ºF Air-Cooled and Insulated ECO-STEEL Chimney Size 13

ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

INSTALLATION INSTRUCTIONS

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4

Before selecting your stove, it is very important that you clearly identify what your needs are:

The intelligent alternative for flue gas venting systems

SWB400I DELUXE RADIANT WOOD BURNING FIREPLACE INSTALLATION, OPERATION AND MAINTENANCE MANUAL

EUTECTIC EC-10DV Series

Vent and air piped through a side wall (concentric termination)

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.

Malm Fireplaces, Inc. 368 Yolanda Avenue, Santa Rosa, CA (707) Fax: (707)

Installation and Maintenance Instructions. Double Wall AL 29-4C Stainless Steel Special Gas Vent and Type L Vent

INSTALLATION INSTRUCTIONS FOR THROUGH-THE-WALL VENTING COMPONENTS

The Monterey (PENNINSULA) MODEL PN36 3-SIDED, WOOD-BURNING FIREPLACE

Transcription:

PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

Specifications Applications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel. It is also built to vent biofuel products such as corn, switch grass, cherry pits, soybeans, coffee husks, sunflower hulls, walnut shells and wheat, to name a few. (Rated for continuous use flue temperatures up to 570 F.) Materials and Construction Laser-welded, double-wall pipe with a.012 inner wall of 444 stainless steel and a.018 laser-welded galvalume outer wall. Painted black exterior available. Primary metal-to-metal connection seals joint. Encapsulated o-ring provides a secondary seal. Clearances 1 clearance to combustibles in the USA and Canada for appliances using corn and other biofuels, wood pellets or oil. UL 641, ULC S609, and ULC/ORD C441 System PelletVent Pro for biofuels All PelletVent Pro components that come into contact with flue gases are built with an inner wall of corrosion resistant superferritic metal. PelletVent Pro is engineered with features for a durable, safe and aesthetically pleasing venting system. PelletVent Pro is a patent-pending venting system for stoves and inserts that use wood pellets, corn and other biofuels, or oil, as fuel. As a result of DuraVent s cutting-edge manufacturing process and commitment to innovation, PelletVent Pro is uncompromised in attention to detail and performance. This perfect fit and finish is made possible with a laser-welded inner and outer wall. Select components are available in black. PelletVent Pro is UL listed for 1 clearance to combustibles in the USA and in Canada. It s double-wall, air-insulated design offers superior performance. Seams are factory-sealed on all elbows, tees, and fittings. Since the introduction of pellet stoves in the 1980 s, DuraVent is recognized as the industry leader in venting systems for pellet stoves. For over 20 years, DuraVent's Pellet Vent has been the number 1 choice for installers. Diameters 3 & 4 Listings c-ul-us Listed to UL 641 (MH8381 and MH14420). ULC Listed to ULC S609, ULC/ORD C441 (CMH1439 and CMH1440). 131 M&G DuraVent www.duravent.com

Combustion Air System PelletVent Pro The Combustion Air System (CAS) is a system designed to bring in outside combustion air directly to your pellet stoves. This eliminates the use of conditioned inside air for combustion, improving the efficiency of central heating systems. Combustion Air System is a patent-pending design that pre-heats combustion air. Inbound air is circulated through baffles around the heated areas of the support box or wall thimble. For PelletVent Pro, the pre-heated air is delivered down a wall channel to assure that the pellet vent is not cooled. CAS enables outside air to be used as combustion air below grade. The wall thimble and wall channel provide combustion air to the pellet stove when used in a below grade (basement installation. Pellet stoves utilize the adjustable air channel. CAS also minimizes down-drafts in below grade installations. It does not consume warm indoor air for combustion and not subject to oxygen starvation, poor draft and other problems associated with tight energy efficient homes. Specifications Combustion Air Systems for PelletVent Pro Applications Multi-fuel system designed to provide air to the appliance for combustion. Provides a 3 air intake for the appliance. Materials and Construction Laser-welded, double-wall pipe with a.012 inner wall of 444 stainless steel and a.018 laser-welded galvalume outer wall. Primary metal-to-metal connection seals joint. Encapsulated o-ring provides a secondary seal. Clearances 1 clearance to any combustibles. Diameters 3 and 4 Listing c-ul-us (MH8381) This system simplifies installation with only one wall or ceiling penetration, eliminating the need for a second penetration in the building envelope to introduce combustion air. The design is simple and elegant with decorative black finish. All products are factory finished in matte black. LOOKING FOR DIRECT VENT PELLET INSTALLATIONS? See the NEW CVS section of the catalog on page 214. 800-835-4429 M&G DuraVent 132

PelletVent Pro iofuel Chimney Typical Installations 1 16 8 4 8 2 3 Installation Key 1 Vertical Cap 10 Horizontal Cap with Rigid Pipe 2 Storm Collar 11 Wall Thimble 3 Flashing 12 Ceiling Support Firestop Spacer 4 Cathedral Ceiling Support ox 13 Tee w/ Clean-Out Tee Cap 5 Straight Length Pipe 14 Wall Strap 6 45 Elbow 15 Attic Insulation Shield 7 Appliance Adapter 16 Prairie Termination Cap 8 Flex Length 17 CAS Adjustable Wall Channel 9 90 Elbow 16 Co-Linear SS Flex Installation for Pellet Inserts 1 2 1 3 7 Cathedral Ceiling Stove Installation 5 13 2 Refer to our Typical Venting Installation drawings to select the appropriate component parts for your installation. The inner pipe diameter should match the outlet size of the appliance. For installations that require 4 vent and the appliance has a 3 outlet, use an Increaser Adapter 3-4. Check the appliance manufacturer's installation instructions to confirm which types of vent configurations are permitted (i.e. horizontal, vertical, chimney reline, etc.). Also, check for any venting restrictions such as maximum horizontal run, minimum and maximum vertical rise, maximum offset, etc. e fire safe! Maintain the minimum clearances (air-space) between the vent pipe and nearby combustibles, as specified in the appliance manufacturer's installation instructions. Use proper support and bracing. Follow local building codes and have your venting system inspected. 3 6 5 5 14 9 13 13 7 12 13 Round Horizontal Cap 90 Elbow Wall Strap 7 Straight Length Pipe Masonry Chimney Relining with Rigid Pipe Attic Offset Tee with Clean-Out Tee Cap 9 Wall Thimble 5 7 10 17 5 Appliance Adapter 13 Through-The-Wall using CAS Vertical Rise Through-The-Wall 10 11 7 133 M&G DuraVent www.duravent.com

ring In the Fresh Air Combustion Air System For PelletVent Pro CAS system for PelletVent Pro can be used for horizontal (through-the-wall) installations. The CAS System cannot be used with vertical (through-the-ceiling) installations. The PelletVent Pro CAS stove system is available in 3 and 4 pellet chimney sizes. The system s pellet stove wall thimble is designed with an air channel to direct combustion air into the appliance or as a direct vent system allowing for closer placement to windows. PelletVent Pro CAS is considered Table a direct vent for pellet appliances, which øa C allows for clearances down to 12 inches to building openings, as defined by NFPA 211. 3 3/4 9 14 3/4 4 3/4 9 14 3/4 iofuel Chimney PelletVent Pro Combustion Air Wall Thimble Kit 0A Includes Wall Thimble, Channel Adapter, Flex and 2 to a direct vent for bringing outside air for combustion through an adjustable air channel in wall thimble to appliance without cutting a second hole into the wall. Minimizes down drafts in below-grade installations. Patent-pending. 07 C 4-6½ SIZE 3 4 A 3 3 4 4 3 4 9 9 C 14 3 4 14 3 4 ORDER # 3CAS-WTPK 4CAS-WTPK STOCK # 810000894 810000895 03 Combustion Air Adjustable Wall Channel Telescoping Wall Channel 36"-70". Shown here attached to Combustion Air Wall Thimble Kit (not included). SIZE 3 & 4 ORDER # CAS-C70A STOCK # 810006860 36" - 70" Adjustable 800-835-4429 M&G DuraVent 134

PelletVent Pro iofuel Chimney Planning Your Installation 1 2 3 4 5 6 7 Refer to the Typical PelletVent Pro Installations diagram, on the opposite page, to be familiar with some of the standard PelletVent Pro installations and the required component parts. For a horizontal termination, you will need a Wall Thimble and a Horizontal Cap. The cap must be installed with a 6" clearance to the outside wall (refer to appliance manufacturer s installation instructions for other clearances). For a vertical termination, you will need a Cathedral Ceiling Support ox or Flat Ceiling Support, Attic Insulation Shield (if passing through an attic), Flashing, Storm Collar, and Vertical Cap. Determine the length of PelletVent Pro pipe required. For a vertical termination, measure the pitch of the roof and select the proper flashing. The required minimum height above the roof is 12". Pellet stove inserts in masonry fireplaces will require a flex pipe to snake the vent past the smoke shelf. For transition from PelletVent Pro to an existing DuraPlus, DuraPlus HTC, or DuraTech Chimney, a Chimney Adapter is available. For vertical rise of PelletVent Pro on the outside of the house, Wall Straps should be used at 4' intervals to provide proper support. Important! Check to be sure that the appliance and the venting system are in compliance with all minimum clearance to combustible requirements. Design Recommendations 1 Minimum above roof penetration The following design recommendations are a general guideline to assist in the design and selection of venting components for your installation. Always follow DuraVent Installation instructions before installing your chimney system (found with the cap or support box). Installation instructions can be viewed online at www.duravent.com, under Catalogs and Instructions. Size the vent to meet the appliance manufacturer s specifications. Avoid long runs and excessive use of elbows. Refer to the appliance manufacturer for minimum rise and maximum run configurations for the venting system. Use an Appliance Adapter to ensure a proper connection to appliance. Seal adapter to appliance with high temperature sealant. Use a Single Tee with Clean-Out Tee Cap to facilitate easy cleaning. It is recommended to use a tee off the back of an appliance. In the United States and Canada, maintain the minimum 1" clearance (air space) from vent pipe to combustibles. Use proper support and bracing. Follow local building codes and have your venting system inspected. e fire safe! 135 M&G DuraVent www.duravent.com

iofuel Chimney PelletVent Pro PelletVent Pro Horizontal Kit Kit includes: Horizontal Cap, Wall Thimble, and Appliance Adapter. Pipe lengths not included. 4 Kit includes a 3-4 Appliance Adapter/Increaser, painted black. 3 3PVP-KHA 810001029 4 4PVP-KHA 810001035 PelletVent Pro Vertical Kit - Flat Ceiling Kit includes: Vertical Cap, Storm Collar, Ceiling Support Firestop Spacer, Adjustable Flashing, and Appliance Adapter. Pipe lengths not included. 4 Kit includes a 3-4 Appliance Adapter/Increaser, painted black. Support Clamp included. 3 3PVP-KVA 810001031 4 4PVP-KVA 810001036 PelletVent Pro Vertical Kit - Cathedral Kit includes: Vertical Cap, Storm Collar, Cathedral Ceiling Support ox with trim and clamp, Adjustable Flashing, and Appliance Adapter. Pipe lengths not included. 4 Kit includes a 3-4 Appliance Adapter/Increaser, painted black. 3 3PVP-KV 810001033 4 4PVP-KV 810001037 800-835-4429 M&G DuraVent 136

PelletVent Pro iofuel Chimney Fresh Air Intake Kit Kit includes: faceplate with screen, moisture barrier, aluminum flex, and two clamps. 5 5 Allows fresh air into an existing pellet stove installation that had been using inside air. Allows an installer to decide the best possible location for the air intake vent, not the same location as the wall thimble. The 2 diameter flex hose expands to approximately 10. ¾ 3 3PVP-AIK 810001034 Straight Length Pipe Features fully unitized, twist-lock construction in 3 and 4 diameters. Listed at 1 clearance to combustibles in the USA and Canada. It can be used in both vertical and horizontal installations. Stainless steel welded seam inner wall, combined with a galvalume welded seam outer wall. Pipe OD is diameter plus 5 8. Galvalume or painted black outer finish. 12 length available with stainless steel outer (SS). To calculate installed length, subtract 1 1 2 from each length of pipe. SIZE 3 4 ORDER # STOCK # ORDER # STOCK # 6 3PVP-06 810001038 4PVP-06 810001104 6 LACK 3PVP-06 810001039 4PVP-06 810001105 12 3PVP-12 810001040 4PVP-12 810001106 12 LACK 3PVP-12 810001041 4PVP-12 810001107 12 STAINLESS STEEL 3PVP-12SS 810001042 4PVP-12SS 810001108 24 3PVP-24 810001043 4PVP-24 810001109 24 LACK 3PVP-24 810001044 4PVP-24 810001110 24 STAINLESS STEEL 3PVP-24SS 810001045 4PVP-24SS 810001111 36 3PVP-36 810001046 4PVP-36 810001112 36 LACK 3PVP-36 810001047 4PVP-36 810001113 60 3PVP-60 810001048 4PVP-60 810001114 60 LACK 3PVP-60 810001049 4PVP-60 810001115 137 M&G DuraVent www.duravent.com

iofuel Chimney PelletVent Pro Pipe Extension Use to add length to PelletVent Pro pipe. 12 pipe adds 3-10 of length, 18 pipe adds 3-16 of length, when used with rigid sections of pipe. Galvalume or painted black outer finish. 8½ A A 3 3PVP-12A 810001050 3-10 3 LACK 3PVP-12A 810001051 3-10 3 3PVP-18A 810001052 3-16 3 LACK 3PVP-18A 810001053 3-16 3 3PVP-48A 810001054 4-46 3 LACK 3PVP-48A 810001055 4-46 4 4PVP-12A 810001116 3-10 4 LACK 4PVP-12A 810001117 3-10 4 4PVP-18A 810001118 3-16 4 LACK 4PVP-18A 810001119 3-16 4 4PVP-48A 810001120 4-46 4 LACK 4PVP-48A 810001121 4-46 Increaser 23 8 4¾ Use to transition from 3 pipe to a 4 pipe. Not a decreaser or stove adapter. 3-4 3PVP-X4 810001100 Flex Pipe Use for offsetting rigid pipe around smoke shelf in masonry chimney only. Allows for offsets with biofuel appliances. Female and male ends twist-lock. Female end swivels for easy alignment. 10 flex section. Not for use in attic or wall spaces. 3 3PVP-60F 810001056 4 4PVP-60F 810001122 800-835-4429 M&G DuraVent 138

PelletVent Pro iofuel Chimney Flex Trim Collar 3¾ Use to connect PelletVent Pro rigid pipe to a masonry chimney with stainless steel flexible relining. Female end swivels to allow ease of connection. A A 3 3PVP-FTC 810001092 3 ³ 8 8 ½ 4 4PVP-FTC 810001156 4 5 8 8 ½ Female Flex Adapter Use to connect PelletVent Pro to ioflex when relining a masonry chimney. Only approved for use with ioflex. 4 3 3PVP-ADFF 810001062 4 4PVP-ADFF 810001125 Male Flex Adapter Use to connect ioflex to PelletVent Pro when relining a masonry chimney. Only approved for use with ioflex. 3¾ 3 3PVP-ADFM 810001063 4 4PVP-ADFM 810001126 Appliance Adapter Use to attach to appliance outlet allowing for easy pipe connection. Seal adapter to appliance with high temperature sealant. A SIZE STOCK # 3 3PVP-AD 810001057 4 4PVP-AD 810001123 3 LACK 3PVP-AD 810001058 4 LACK 4PVP-AD 810001124 139 M&G DuraVent www.duravent.com

iofuel Chimney PelletVent Pro Quick Release Adapter A Use to attach to appliance outlet allowing for easy pipe connection. Features an adjustable hose clamp and gasket to form a tight seal. The hose clamp can be loosened and tightened as needed to disconnect and connect the vent to the appliance. A 4-6 3PVP-ADS 810006994 3 3 ½ 4-8 4PVP-ADS 810006995 4 3 ½ Ravelli, 80mm Adapter A Use to provide a secure, tight fit to the exhaust outlet on any Ravelli Pellet Stove. Seal with high temperature silicone sealant to insure a tight connection. A 3 3PVP-ADR 810013232 3 1/4 4 1/4 Harman Adapter Use to provide a secure, tight fit to the exhaust outlet on any Harman Pellet Stove. Seal with high temperature silicone sealant to insure a tight connection. 3 3PVP-ADH 810001059 Harman Adapter Increaser Use to increase vent diameters. Specifically designed for Harman Pellet Stoves. 3 3PVP-X4ADH 810005891 800-835-4429 M&G DuraVent 140

PelletVent Pro iofuel Chimney Appliance Adapter/Increaser 3½ 4 Use to attach to appliance outlet allowing for easy pipe connection. Allows connection of 4 vent to 3 appliance outlet. Seal adapter to appliance with high temperature sealant. 3 3PVP-X4AD 810001060 3 LACK 3PVP-X4AD 810001061 45 Elbow Offsets obstructions as needed. Elbows swivel 360 at base. Angle not adjustable. A A 3 3PVP-E45 810001064 3 7 8 4 3 LACK 3PVP-E45 810001065 3 7 8 4 4 4PVP-E45 810001127 3 7 8 4 4 LACK 4PVP-E45 810001128 3 7 8 4 90 Elbow Offsets obstructions as needed. Elbows swivel 360 at base. Angle not adjustable. A A 3 3PVP-E90 810001066 5 ½ 5 ½ 3 LACK 3PVP-E90 810001067 5 ½ 5 ½ 4 4PVP-E90 810001129 5 ½ 5 ½ 4 LACK 4PVP-E90 810001130 5 ½ 5 ½ 141 M&G DuraVent www.duravent.com

iofuel Chimney PelletVent Pro Single Tee w/ Clean-Out Tee Cap Use for a 90 offset. ranch swivels for alignment. One piece unit incorporates removable twist-lock Clean-Out Tee Cap. A 3 3PVP-T 810001068 3 LACK 3PVP-T 810001069 4 4PVP-T 810001131 4 LACK 4PVP-T 810001132 C Increaser Tee w/ Clean-Out Tee Cap Attaches 3 pipe to branch and 4 pipe to body. Use for a 90 offset. ranch swivels for alignment. One piece unit incorporates removable twist-lock Clean-Out Tee Cap. 10 1/8 4 4PVP-T3 810001133 4 LACK 4PVP-T3 810001134 5 1/16 5 1/16 Adapter Tee w/ Clean-Out Tee Cap Use for a 90 offset. Attaches directly to appliance as an adapter. One piece unit incorporates removable twist-lock Clean-Out Tee Cap. A C Ø 3 4" ØA 3 3PVP-TAD 810001070 3 3 5 8 3 LACK 3PVP-TAD 810001071 3 3 5 8 4 4PVP-TAD 810001135 4 4 5 8 4 LACK 4PVP-TAD 810001136 4 4 5 8 D E 800-835-4429 M&G DuraVent 142

PelletVent Pro iofuel Chimney Increaser Adapter Tee w/ Clean-Out Tee Cap Use for a 90 offset. Attaches directly to appliance as an adapter. Converts a 3 appliance to a 4 PelletVent Pro system. One piece unit incorporates removable twist-lock Clean-Out Tee Cap. 10 5 1 2 4 5/8 6 ¼ 7/8" Ø 35/8 3 3PVP-TADX4 810001072 3 LACK 3PVP-TADX4 810001073 LOOKING FOR DIRECT VENT PELLET OPTION? See the NEW CVS section of the catalog. Double Tee w/ Clean-Out Tee Cap Allows clean-out access for horizontal and vertical installations. Use for a 90 offset. ranch swivels for alignment. One piece unit incorporates removable twist-lock Clean-Out Tee Cap. D Ø E ØA Ø A C D 3 3PVP-DT 810001074 3 3 5 8 4 5 8 4 1 2 3 LACK 3PVP-DT 810001075 3 3 5 8 4 5 8 4 1 2 4 4PVP-DT 810001137 4 4 5 8 5 1 8 5 4 LACK 4PVP-DT 810001139 4 4 5 8 5 1 8 5 C Ø C Clean-Out Tee Cap 2 ½ Use as a replacement Clean-Out Tee Cap. The new PelletVent Pro Tee Cap is a tight fit by design. We recommend using rubber gloves or a strap wrench to easily remove. 3 3PVP-CO 810001076 3 LACK 3PVP-CO 810001077 4 4PVP-CO 810001138 4 LACK 4PVP-CO 810001140 Wall Thimble 3 7/8 to 8 ØA 9 1 Clearance 7 Use for through-the-wall installations. Fits between standard wall studs. Comes with an insulation ring to reduce air infiltration where the pipe slips through the thimble. A 3 3PVP-WT 810001081 3 3 4 4 4PVP-WT 810001145 4 3 4 143 M&G DuraVent www.duravent.com

iofuel Chimney PelletVent Pro Combustion Air Wall Thimble Kit 0A A direct vent for bringing outside air for combustion through an adjustable air channel in wall thimble to appliance without cutting a second hole into the wall. Minimizes down drafts in below-grade installations. Patent-pending. A C C 3 3CAS-WTPK 810000894 3 3 4 9 14 3 4 4 4CAS-WTPK 810000895 3 3 4 9 14 3 4 4-6½ 07 03 Wall Thimble Air Intake Kit 7 4-8 13 ØD 13 ½ Allows outside fresh air for combustion through the wall thimble without having to cut a second hole into the wall. Comes with an insulation ring to reduce air infiltration where the pipe slips through the thimble. The 2 diameter flex hose is 10 in length. Clamps included. Can be used in US and Canada. Patented. SIZE FLEX 0 ORDER # STOCK # 3 2 3PVP-WTI 810001083 4 2 4PVP-WTI 810001147 4 3 4PVP-WTI3 810001148 Ceiling Support Firestop Spacer ØA 9 Required where vent passes through ceiling. Centers pipe to provide proper 1 clearance. Support Clamp included. Painted black. A 3 3PVP-FS 810001084 3 3 4 4 4PVP-FS 810001149 4 3 4 1 Clearance 800-835-4429 M&G DuraVent 144

PelletVent Pro iofuel Chimney Ceiling Support Firestop Spacer - 3" Clearance C 11 Required where vent passes through ceiling. Centers pipe to provide 3 clearance. Support Clamp included. Painted black. A C 3 3PVP-FS3 810001085 3 3 4 9 5 8 11 5 8 4 4PVP-FS3 810001150 4 3 4 10 5 8 12 5 8 ØA C 3 Clearance Wall Strap Use to support vent pipe or tee sections. Provides 1 clearance. 1 ØA 2 A 3 3PVP-WS 810001086 3 5 8 4 4PVP-WS 810001151 4 5 8 Adjustable Wall Strap Use to support vent pipe or tee sections. Adjusts to provide 1-3 clearance. 1 to 3 ØA 2 A 3 3PVP-WSA 810001087 3 5 8 4 4PVP-WSA 810001152 4 5 8 Wall Strap Extension Use with Adjustable Wall Strap to increase extension from wall. Fits both 3 and 4 Adjustable Wall Strap. 6 2 3-4 3PVP-WSA-EXT 810001088 145 M&G DuraVent www.duravent.com

iofuel Chimney PelletVent Pro Cathedral Ceiling Support ox Use to support pipe. May be used on flat ceilings. Painted black. Trim and clamp included. 14¾ A 10¾ ØA 14¾ 3 3PVP-CS 810001089 3 3 4 4 4PVP-CS 810001153 4 3 4 14 10¾ House Shield Use to protect exterior of structure from blower discharge in horizontal venting applications. 12 ØA 12 ¾ A 3 3PVP-HS 810001090 3 3 4 4 4PVP-HS 810001154 4 3 4 Attic Insulation Shield Ø3⅝ & Ø4⅝ Ø6¾ Adjusts 11-20 Required for installations that pass through an attic to prevent insulation and debris from accumulating near the vent. Provides 1 clearance to combustibles. 3 3PVP-IS 810001093 4 4PVP-IS 810001157 7 3/16 9 3/16 800-835-4429 M&G DuraVent 146

PelletVent Pro iofuel Chimney Adjustable Roof Flashing 16 Use to weather proof the penetration of vent pipe through the roof. Storm Collar required. Select roof flashing based on pitch of roof. For pitches of 0/12-6/12. For steep roof pitches, refer to the Type Gas Vent section. 4¼ ØA 17 A 3 3PVP-F6 810001094 3 3 4 4 4PVP-F6 810001158 4 3 4 Tall Cone Roof Flashing 16 ØA 17 11 Use to weather proof the penetration of vent pipe through the roof. Storm Collar required. Select roof flashing based on pitch of roof. Use on flat roofs, chase enclosures, or masonry chimney. Made of galvalume. A 3 3PVP-FF 810001095 3 3 4 4 4PVP-FF 810001159 4 3 4 DSA Roof Flashings Use with metal or tile roofs. Available in sizes 3 and 4, in 0/12-6/12 (shown) and 7/12-12/12 styles. Made of dead soft aluminum. A C A C 3 0/12-6/12 3PVP-F6DS 810001096 3 3 4 19 3 8 23 7/12-12/12 3PVP-F12DS 810001097 3 3 4 19 3 8 23 4 0/12-6/12 4PVP-F6DS 810001160 4 3 4 19 3 8 23 7/12-12/12 4PVP-F12DS 810001161 4 3 4 19 3 8 23 Storm Collar Ø ØA Use to maintain a weather tight resistant seal between the pipe and the flashing. A 3 3PVP-SC 810001091 3 5 8 7 3 8 4 4PVP-SC 810001155 4 5 8 8 1 8 147 M&G DuraVent www.duravent.com

iofuel Chimney PelletVent Pro Vertical Cap Use for vertical installations only. Required where pipe terminates above the roof line. 8 6 3 3PVP-VC 810001078 4 4PVP-VC 810001141 Horizontal Cap 5 3 4 Ø2 5 8 Use for horizontal terminations only. The Horizontal Cap can be turned at the gore to direct exhaust output. Designed to create a venturi effect to force exhaust out. Made of a laser-welded, super-ferritic stainless steel inner wall that is scientifically proven to resist corrosion from corn and other biofuels. Outer wall made of laser-welded stainless steel. 5 1 8" Ø3 5 8 3 3PVP-HC2 810009646 4 4PVP-HC2 810001143 Square Horizontal Cap 8 ¼ 8 Use for horizontal terminations only. Cap features swivel collar to adjust exhaust direction. Cap features an optional swivel base. 3 3PVP-HSC 810001080 4 4PVP-HSC 810001144 Ceiling Support/ Wall Thimble Cover 13 Decorative cover for ceiling support boxes and wall thimbles. Painted black. Use with reduction collar. 3-4 3PVP-WTC 810001098 Ø6⅞ 13 1 800-835-4429 M&G DuraVent 148

PelletVent Pro iofuel Chimney Reduction Collar Ø9 ¼ Reduces the center hole diameter in the Ceiling Support /Wall Thimble Cover to fit 3 or 4 pipe. Can be used as trim collar when penetrating a masonry chimney with PelletVent Pro. Painted black. ØA A 3 3PVP-RC 810001099 3 3 4 4 4PVP-RC 810001162 4 3 4 Chimney Adapter 3½ 7 Use to transition between PelletVent Pro to existing chimney such as DuraTech, DuraPlus or DuraPlus HTC. Requires a DVL/Duralack Chimney Adapter to fasten into support box or wall thimble, for 6, use adapter 6DVL-ADC or 6DVL-ADT, for 8, use adapter 8DVL-ADC or 8DVL-ADT. 3-6 3PVP-X6 810001101 3-7 3PVP-X7 810008056 3-8 3PVP-X8 810001102 4-6 4PVP-X6 810001163 4-7 4PVP-X7 810008057 4-8 4PVP-X8 810001164 ioflex Pipe Use when relining masonry chimney for use with biofuel appliances. Made of super-ferritic stainless steel. Must be used with PelletVent Pro Male and Female Flex Adapters. Rigid pipe must be used when terminating system. SIZE 3 4 ORDER # STOCK # ORDER # STOCK # 15 FLEX 3PVP-15F 810001165 4PVP-15F 810001171 20 FLEX 3PVP-20F 810001166 4PVP-20F 810001172 25 FLEX 3PVP-25F 810001167 4PVP-25F 810001173 30 FLEX 3PVP-30F 810001168 4PVP-30F 810001174 35 FLEX 3PVP-35F 810001169 4PVP-35F 810001175 100 FLEX 3PVP-100F 810001170 4PVP-100F 810001176 149 M&G DuraVent www.duravent.com

iofuel Chimney PelletVent Pro Prairie Termination Cap 114/5 8 1/2 18 18 Use when installing a pellet insert into a multi-fuel pellet stove. This termination cap supplies both fresh air and vents exhaust. Lid pivots open for cleaning with three Removable screws and one rivet. Flex sold separately. 304SS and 316SS flex can be used when burning most fuels. If burning corn, super-ferritic stainless steel bio-flex must be used as the exhaust vent. For fresh air, aluminum flex can be used. Stainless steel flex is not required for the fresh air supply unless specified by the appliance manufacturer. VENT EXHAUST AIR INTAKE 3 3PVP-VCT33 810006996 3 3 3 LACK 3PVP-VCT33 810005890 3 3 4 4PVP-VCT34 810006997 4 3 4 LACK 4PVP-VCT34 810006998 4 3 Fresh Air Inlet Increaser 115/16 Use to increase an insert s 2 air inlet to connect to 3 aluminum flex. 3 3PVP-INC 810001103 3¾ 3 Pellet Vent Factory-uilt Reline Kit Use to reline an existing factory-built chimney or vent. Can be used for wood, pellet, and biofuel burning appliances. SIZE 304 Length 316 Length ORDER # STOCK # ORDER # STOCK # 3 Diameter 20 Length 3PVP304-20KF 810009339 3PVP316-20KF 810009340 4 Diameter 35 Length 4PVP304-35KF 810009341 4PVP316-35KF 810009342 800-835-4429 M&G DuraVent 150

PelletVent Pro iofuel Chimney Offset Chart OFFSET OFFSET RISE RISE Elbow Angle Chimney Length Ø3 Ø3 Ø4 Ø4 from Vertical etween Elbows Offset Rise Offset Rise 45 0 3 ¾ 10 ¼ 4 ¼ 12 ¼ 45 6 7 13 ½ 7 ½ 15 ½ 45 12 11 ¼ 17 ¾ 11 ¾ 19 ¾ 45 24 19 ¾ 26 ¼ 20 ¼ 28 ¼ 45 36 28 ½ 34 ¾ 28 ¾ 36 ¾ 45 24 + 24 35 ½ 42 36 44 45 60 45 ¼ 51 ¾ 45 ¾ 53 ¾ 45 36 + 36 52 ½ 59 53 61 90 0 8 ¼ 9 ¾ 10 11 ½ 90 6 12 ¾ 9 ¾ 14 ½ 11 ½ 90 12 18 ¾ 9 ¾ 20 ½ 11 ½ 90 24 30 ¾ 9 ¾ 32 ½ 11 ½ 90 36 42 ¾ 9 ¾ 44 ½ 11 ½ 90 24 + 24 53 ¼ 9 ¾ 55 11 ½ 90 60 66 ¾ 9 ¾ 68 ½ 11 ½ 90 36 + 36 77 ¼ 9 ¾ 79 11 ½ 151 M&G DuraVent www.duravent.com