COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2012 Supersedes

Similar documents
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Safety, Installation, and Operation Manual

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING


ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

INSTALLATION INSTRUCTIONS

PACKAGED UNITS KITS AND ACCESSORIES 10/2009 INSTALLATION INSTRUCTIONS FOR SMOKE DETECTOR KITS USED WITH KC/KG/KH & LCH/LGH UNITS

INSTALLATION INSTRUCTIONS

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

CP CP

PACKAGED UNITS KITS AND ACCESSORIES. 7/2011 Supersedes 5/2011

Marvel S MICROPROCESSOR CONTROLLER. Installation, Operation and Maintenance Manual Effective October 2018 DISCONTINUED. For Reference Only

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

AIR HANDLING SYSTEM RETRO-COMMISSIONING TRENDING ANALYSIS

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

Technical Reference Manual Design and Application Guide for Honeywell Economizer Controls

Reference Guide for Microprocessor Controller

CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS)

FOR SERVICE TECHNICIAN S USE ONLY

Digital Precise Air Control - DPAC

Reference Guide for Microprocessor Controller

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

I-TEC ERV Economizer Ventilator System (Vent Code "E")

Installation and Setup Guide

SEQUENCE OF OPERATIONS

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

1.0 Digital Controller

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

Installation Guide.

CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

Installation Instructions

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

INSTALLATION INSTRUCTIONS

Installation Instructions

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

Safety and Installation Instructions Model 1700

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

CAUTION. No-Load Performance, Controls in Normal Position

FOR SERVICE TECHNICIAN S USE ONLY

L SERIES UNITS 505,191M. 4/2006 Supersedes 504,908M

B24 SERVICE UNIT INFORMATION B24 SERIES ADD-ON BLOWER ECB24 SERIES ELECTRIC HEAT

LZP-2 ZONE CONTROL PANEL

L SERIES UNITS 504,908M. 10/2004 Supersedes 9/2004

CAUTION. All safety information must be followed as provided in Service Manual RS ! WARNING

AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION

SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES

CommStat 4 Controller

Reference Guide for Microprocessor Controller

Installation Instructions

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

THIS IS A DESIGN GUIDE NOT A SPECIFICATION. Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL

50TM TFF COMBINATION HEATING/COOLING UNITS

L SERIES UNITS 504,520M. 10/2001 Supersedes 504,413M

EnviroZone-4 & EnviroZone-2 Quick-Start Guide

50TM COMBINATION HEATING/COOLING UNITS

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide.

Advance Release September 2009

DIGI-VAV APPLICATIONS

Installation Instructions

Wiring Instructions. High-Capacity Steam Humidifiers

DIGI3U. Zoning Systems. Installation Guide. That s all we do. Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

Wiring Diagrams DIAGRAM INDEX

SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS

REPLACEMENT PARTS LIST

Comparative Enthalpy Kit

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

FOR SERVICE TECHNICIAN S USE ONLY

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

INSTALLATION INSTRUCTIONS

T-32-TS Touchscreen Thermostat. Installation Manual

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP RECIRCULATION AIR WITH ECONOMIZER

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

AirTrak. Digital Control System. User Manual. Touchscreen Systems

Performance and Reliability. CB*, C* and TA* Models

FAN POWERED VAV TERMINALS

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL

York 25-Ton VAV Rooftop Unit

Model 8120 and 8126 Safety & Installation Instructions

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

FAN POWERED VAV TERMINALS

JADE Economizer Module (MODEL W7220)

SA Series Start up Report

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Bottom Mount Refrigerator---Technical Information

Transcription:

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES 506956 01 2/2012 Supersedes 506167 01 Litho U.S.A. TAA ECONOMIZERS INSTALLATION INSTRUCTIONS FOR ECONOMIZERS (44W94, 44W95 AND 44W96) USED WITH TAA SERIES UNITS FRESH DAMPER RETURN DAMPER CONTROL ACCESS PANEL RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING Improper installation, adjustment, alteration, service or maintenance can cause personal injury, loss of life, or damage to property. Installation and service must be performed by a licensed professional installer (or equivalent) or a service agency. CAUTION Physical contact with metal edges and corners while applying excessive force or rapid motion can result in personal injury. Be aware of, and use caution when working near these areas during installation or while servicing this equipment. WARNING Electric Shock Hazard. Can cause injury or death. Line voltage is present at all components on units with single-pole contactors, even when unit is not in operation! Unit may have multiple power supplies. Disconnect all remote electric power supplies before opening access panel. Unit must be grounded in accordance with national and local codes. Shipping and Packing List Check parts for shipping damage; if any damage is found, immediately contact the last shipping carrier. Package 1 of 1 contains the following: (1) Mixing box assembly, control wiring assembly, mixed air sensor (R1) and enthalpy sensor (A7) (18) #10 16 x 1/2 SDST screws (3) Wire ties Application Mixing boxes are used for automatic sensor controlled introduction of outdoor air into the system through an electro mechanically controlled damper. TAA units in upflow and horizontal air discharge applications. For units equipped with an inverter (VFD) driven indoor blower motor, refer to the VFD kit installation instructions for additional setup requirements. Economizer dampers will modulate to maintain 55ºF (13ºC) supply air when outdoor air is suitable. The mixed air temperature sensor (R1) measures the supply air sensible temperature. An enthalpy sensor (A7) is used to determine whether outdoor air is suitable for free cooling. The enthalpy sensor is factory installed in all economizers. Other outdoor and return air (OA and RA) sensor options are available to determine whether outdoor air is suitable for free cooling. See table 1 and the instructions provided with optional sensors. The mixed air sensor is provided with the economizer and installed according to these instructions. Sensors Single Outside Air (OA) Sensible Differential Sensible 1 in OA and 1 in RA Differential Enthalpy 1 in OA and 1 in RA* Table 1. Sensors Dampers modulate to maintain 55 F mixed air (R1) when: OA temperature (RT26) is lower than free cooling setpoint. OA temperature (RT26) is lower than return air (RA) temperature (RT27). OA temperature and humidity (A7) is lower than RA temperature and humidity (A62). * indicates default factory configuration. 2/2012 506956 01 Page 1

ECONOMIZER DIMENSIONS C 20 1/2 (521) B C NOTE ECONOMIZER SECTION MAY. BE ROTATED 180 FOR BOTTOM RETURN CONNECTION. 27 (686) RETURN 3/4 (19) 3 (76) TOP VIEW A 3/4 (19) 3/4 (19) SUPPLY OUTDOOR 24 1/2 (622) C 20 1/2 (521) B C SIDE VIEW 3/4 (19) 7/8 (22) END VIEW Model No. A B C (Air Handler Usage) in. mm in. mm in. mm T2ECON31L 1 (072 090) 32 813 30 762 1 25 T2ECON31M 1 (120 150) 51 1/2 1308 45 1143 3 1/4 83 T2ECON31N 1 (180 240) 72 1829 60 1524 6 152 Page 2

ECONOMIZER APPLICATIONS SUPPLY UPFLOW 1 HANDLER SECTION RETURN MOUNT MIXING SENSOR (R1) IN THIS GENERAL LOCATION TO MEASURE SUPPLY SENSIBLE TEMPERATURE. OUTDOOR 1 ECONOMIZER 1 NOTE ECONOMIZER AND HANDLER MUST BE PROPERLY SUPPORTED. RETURN 1 ECONOMIZER 1 ALTERNATE ECONOMIZER LOCATION OUTDOOR MOUNT MIXING SENSOR (R1) IN THIS GENERAL LOCATION TO MEASURE SUPPLY SENSIBLE TEMPERATURE. HORIZONTAL 1 HANDLER 1 ECONOMIZER OUTDOOR 1 NOTE ECONOMIZER AND HANDLER MUST BE PROPERLY SUPPORTED. RETURN 1 ECONOMIZER RETURN MOUNT MIXING SENSOR HERE 1 ALTERNATE ECONOMIZER LOCATION OUTDOOR Figure 1. Upflow and Horizontal Applications Page 3

Figure 2. Typical TAA Control Wiring Page 4

Figure 3. Economizer Control Wiring Page 5

Installation 1. Disconnect all power to the unit. 2. Determine the application (upflow or horizontal). UPFLOW OR HORIZONTAL APPLICATIONS 1. Attached mixing box over return opening with screws provided (figure 4) 2. Remove control access panel on both the mixing box and TAA unit. NOTE Wiring and controls are the same regardless of unit size or application. 3. Route mixing box wiring harness and mixed air sensor wiring over indoor air blower and make necessary connections. For mounting location of mixed air sensor see figure 1. NOTE Ensure the mixed air sensor is mounted up stream of evaporator. 4. Remove and discard existing P3 plug from J3 jack on unit wiring harness (figure 2). 5. Mixing box wiring harness connector P4 plugs into air handler s mating jack J3. 6. Use provided wire ties to secure excess coiled wire to blower motor capacitor leads. WARNING Do not connect economizer plug P4 to air handler J2 when using a temperature control system. Control damage could result. See control wiring diagram for proper jack/plug connections. 7. Replace control access panel on mixing box and unit. 8. Place return and fresh air ducts to mixing box and seal weather tight. NOTE Mixing box section maybe rotated 180º for bottom return air connections (figure 1). 9. Restore power to the unit. SUPPLY OUTLET UPFLOW RETURN INLET CONTROL ACCESS PANEL HORIZONTAL RETURN INLET CONTROL ACCESS PANEL CONTROL ACCESS PANEL Figure 4. Upflow and Horizontal Applications Page 6

Operation COOLING MODE 1. On a call for cooling, with ambient temperature and humidity above enthalpy control set point damper will open to minimum vent position and cooling demand is satisfied by compressor. 2. On a call for cooling, with outside air temperature and humidity (A7) is lower than return air temperature and humidity (A62). the damper will modulate to control supply air temperature at 55ºF (13ºC). If additional cooling is required, compressor will be energized through second stage of thermostat. HEATING MODE 1. On a call for heat during day operation, the damper will open to the minimum vent position. 2. On a call for heat during night operation (requires optional field provided night thermostat with clock), the damper will remain closed. Enthalpy Control LED S A steady green Free Cool LED indicates that outdoor air is suitable for free cooling. A steady green DCV LED indicates that the IAQ reading is higher than setpoint requiring more fresh air. See figure 7. FREE COOLING SETPOINT Single Temperature or Enthalpy Sensing: The enthalpy control (A6) setpoint may be adjustable. Free cooling will be enabled when outdoor air temperature or enthalpy are lower than the free cooling setpoint. The free cooling setpoints for sensible temperature sensors is 55 F. Table 2 shows the free cooling setpoints for enthalpy sensors. Use the recommended setpoint and adjust as necessary. For example: At setting A (table 2), free cooling will be enabled when outdoor air enthalpy is lower than 73 F and 50% RH. If indoor air is too warm or humid, lower the setpoint to B. At setting B, free cooling will be enabled at 70 F and 50% RH. Table 2. Enthalpy Free Cooling Setpoints Control Setting Enthalpy Setpoint At 50% RH A* 73 F (23 C) B 70 F (21 C) C 67 F (19 C) D 63 F (17 C) *Setting A is recommended. Differential Sensing: Two sensors can be used to compare outdoor air to return air. When outdoor air is cooler than return air, outdoor air is suitable for free cooling. Adjust the free cooling setpoint to D in this application. When return air is cooler than outdoor air, the damper will modulate to the minimum position. DAMPER MINIMUM POSITION SETTING NOTE Installed a jumper between TB1 R and OC terminals to maintain occupied status (allowing minimum fresh air). See figure 5. When using an electronic thermostat or energy management system with an occupied/unoccupied feature, remove jumper. Make wire connections to R and OC as shown in literature provided with thermostat or energy management system. Either the jumper wire or optional device must be connected to A1 and A2 for the economizer to function. NOTE If below 50 degrees add jumper from T to T1 during adjustment. (if not the OAD will not open) and to jumper R to OC on TAA terminal strip. TB1 Figure 5. TB1 Terminal R and OC Jumpers 1. Set thermostat to occupied mode if the feature is available. Make sure jumper is in place between TB1 terminals R and OC if using a thermostat which does not have the feature. 2. Rotate MIN POS SET potentiometer to approximate desired fresh air percentage. NOTE On units equipped with an inverter (VFD) driven supply air blower motor, the VFD control board located in the external MSAV mounting box is controlling the minimum damper position of the economizer. Refer to the VFD kit installation instruction for further information. NOTE Damper minimum position can be set lower than traditional minimum air requirements when an IAQ sensor is specified. 3. Measure outdoor air temperature. Mark the point on the bottom line of chart 2 and label the point A" (40 F, 4 C shown). 4. Measure return air temperature. Mark that point on the top line of chart 2 and label the point B" (74 F, 23 C shown). 5. Measure mixed air (outdoor and return air) temperature. Mark that point on the top line of chart 2 and label point C" (70 F, 21 C shown). 6. Draw a straight line between points A and B. 7. Draw a vertical line through point C. 8. Draw a horizontal line where the two lines meet. Read the percent of fresh air intake on the side. Page 7

9. If fresh air percentage is less than desired, adjust MIN POS SET potentiometer clockwise (further open). If fresh air percentage is more than desired, adjust MIN POS SET potentiometer counterclockwise (less open). Repeat steps 3 through 8 until calculation reads desired fresh air percentage. DCV SET AND DCV MAX SETTINGS The DCV SET potentiometer is factory set at approximately 50% of the potentiometer range. Using a standard 1 2000ppm CO 2 sensor, dampers will start to open when the IAQ sensor reads approximately 1000ppm. Adjust the DCV SET potentiometer to the approximate setting specified by the controls contractor. Refer to figure 7. The DCV MAX potentiometer is factory set at approximately 50% of the potentiometer range or 6VDC. Dampers will open approximately half way when CO 2 rises above setpoint. Adjust the DCV MAX potentiometer to the approximate setting specified by the controls contractor. Refer to figure 7. NOTE DCV MAX must be set higher than economizer minimum position setting for proper demand control ventilation. F C 0 10 20 29 10 23 MIXED AND RETURN TEMPERATURE 0 10 20 30 40 50 60 70 80 18 12 7 1 4 10 16 21 27 C B 90 32 100 38 F C 0 10 20 20 30 30 40 40 50 50 60 60 70 70 80 80 90 100 F C 20 29 10 23 0 18 10 12 20 7 30 1 A 40 4 50 10 60 16 OUTDOOR TEMPERATURE 70 21 80 27 90 32 100 38 F C 90 100 Figure 6. Calculate Minimum Fresh Air Percentage Page 8

TEMPORARY INSTALL A JUMPER BETWEEN TR AND TR1 FOR SYSTEM CHECK FACTORY INSTALLED JUMPER BETWEEN P1 AND P DAMPER MINIMUM POSITION IAQ MAXIMUM POSITION (SET HIGHER THAN MINIMUM POSITION) IAQ READING IS ABOVE SETPOINT IAQ SETPOINT OUTDOOR SUITABLE LED FACTORY INSTALLED 620 OHM RESISTOR Figure 7. A6 Enthalpy Control System Check 1. Disconnect main power to unit. 2. Install jumper to auxiliary contacts of blower contactor (B3) in air handler control box. 3. Turn thermostat control to OFF position. 4. Remove economizer control access cover (figure 4). 5. Install jumper on damper motor terminal TR and TR1 (figure 7). 6. Restore power to unit. Damper should drive to fully opened position (requires 1 1/2 minutes for full travel). Observe travel for proper damper operation. 7. Disconnect power to unit. Damper should spring return to closed position. 8. Remove jumper installed on step 5 then restore power to unit. Adjust minimum vent position on potentiometer on control module. Replace control access cover. 9. Disconnect power to unit and remove jumper on auxiliary contacts of blower contactor in main unit control box. Restore power to unit. Maintenance 1. Damper motor is prelubricated and does not require further lubrication. 2. Make visual inspection of dampers and linkage assemblies during routine maintenance. Page 9