Product Specification

Similar documents
Product Specification

Product Specification

OPTICAL AMPLIFIERS SELECTION GUIDE

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

LaserPlus Model LP-OA EDFA OPERATING MANUAL

Features

USER MANUAL. WDM-D15xx.xx. Single Wavelength Add/Drop Module for DWDM

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011

PureGain TM 2600 Variable Gain EDFA for Metropolitan Networks

Optical Fiber Monitor (OFM) Whitebox WB-OFM-1262-DC

OPTICAL FIBER SOLUTIONS

CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L

Wideband Optical Couplers

MINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Noyes OFL 250B Specs Provided by

VIEW500 USER-FRIENDLY STANDARD OTDR

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

GAMMA OTDR application consists of main window and menu. Using menu user can operate in different modes of application.

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

Clearlite Photonic Fibers

Fiber Optical Multiplexer

VIEW500 FASTEST STANDARD OTDR

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

AV6416 OTDR. Product Overview: Main Features:

IFS SFP Tranceivers User Manual

4120 Fire Alarm Network Reference

FTB/FTBx-740C-CWDM Tunable OTDR 18-WAVELENGTH CWDM OTDR FOR METRO ETHERNET AND C-RAN LINK CHARACTERIZATION

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)

PONA Rack Mounted Erbium Doped Fiber Amplifier. User s Manual r001 August 30, W. Chestnut St Alhambra, CA 91803

ETH1000-MKII. User manual

ENCIRCLED FLUX (EF) TEST SOLUTIONS SPSB-EF LAUNCH MODE CONDITIONER AND FLS-600-NS1548 LIGHT SOURCE DESIGNED FOR CONTROLLED MULTIMODE LOSS TESTING

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

Dual SDI Optical to Electrical Converter

EOTec 2C32 Installation Guide

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

MINI2 MOST ACCURATE COMPACT OTDR

MicrOTDR. Optical Fault Locator. User Manual

INTERNATIONAL STANDARD

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1150

CWDM-18. User manual. 18 channel CWDM mux/demux. Rev. B. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion.

FLX380-30x FlexTester OTDR

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS

Remote fiber testing to improve SLA s

FTBx-740C-DWC TUNABLE OTDR C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION

FG-750 Access (P2P)/Metro/Core OTDR-BASED REMOTE FIBER TEST SYSTEM

ETH1000-D. User manual

FTB-730 PON FTTx/MDU OTDR OPTIMIZED FOR ACCESS FIBER DEPLOYMENTS AND TROUBLESHOOTING

MT-RJ Optical Fiber System Field Testing

FTS500 Series. Handheld OTDR Test Set.


Correlation-based OTDR for in-service monitoring of 64-split TDM PON

G4 Pulsed Fiber Laser

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

DDT-4691 & DDR ASI / SD-SDI 8 Channel Mux Fibre Optic Link. User Manual. IRT Electronics Pty Ltd

Four channel video link For low cost video transmission

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1100X

LCP-10G3B4QDRx-G. 10GBASE-LR SFP+ Optical Transceiver FEATURES. Description. Applications. Performance. RoHS compliant

LORAIN CIP 4890/48120 DC Power System

Your benefits using DTS 4148.grandmaster: Features two completely separated LAN ports: provides NTP in two different networks

OTP6123 Series. Handheld OTDR Test Set.

Fibre Specification Standards

FX150 OTDR. Platform Highlights. Key Features

enabling your ideas. Optical, Power and Thermal Management Technologies «Optical racks» for sensing applications

FTS510 Series. Handheld OTDR Test Set.

Important Safety Notice

Agilent E6000A E6003A Specs Provided by E6000C Mini-OTDR. Technical Data Sheet

Set-Up Procedures. Before You Start

LCP-10G3B4HDR(T)-G. 10GBASE-LR Lite SFP+ Optical Transceiver. Description. Applications. Performance FEATURES. RoHS compliance

*For inquiries and questions about lasers, see the Yellow-Page.

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

Combined CAN Sensor Unit Temperature, Humidity and Smoke

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

FiberSystem. Fiber Optic Linear Heat Detection for Special Hazard Applications

iotdr Series Portable OTDR Test Set iotdr Series OTDR Tester is entirely new portable product released by OPWILL.

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

LCP-6144A4EDRx. 10GBASE-SR SFP+ Optical Transceiver FEATURES. Description. Applications. RoHS compliant. Compliant to SFP+ Electrical MSA SFF-8431

OTDR. Optical Time Domain Reflectometer. User Guide

palmotdr Series Handheld OTDR

Fiber Optics and Liquid Level Sensors Line Guide

64 Max IR Thermometer

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

FIRERAY 5000 range USER GUIDE

M210 Multifunction Micro OTDR

Certified Fibre Optic Specialist - Testing

T3/E3 Fiber Optic Line Drivers

FTB-720 LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING

M210 Multifunction Micro OTDR

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Call stations and extensions

M700-Series Multifunction OTDR

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

Agilent E6012A Specs Provided by E6000C Mini-OTDR. Technical Data Sheet

ACTIVE INFRARED BARRIER

FTBx-750C Metro/Long-Haul OTDR LONG-DISTANCE FIBER CHARACTERIZATION AND FIBER UPGRADES

Transcription:

Product Specification R9400SA UltraSpan ROPA Pump Unit 1600 mw Output Power, 3U PN: FOA-R9400SA-RPA6C-AA017 Document No.: 1215607 Revision: A00 Date: 16-Jun-14 Customer: General Product Features Fully controlled ROPA pump unit Hot-swappable pump modules Remote software maintenance and upgrade SNMP v2 or v3 and Web-based GUI Class 1M* laser safety classification 3U rack-mountable packaging Applications Island hopping, desert ranges and oil rigs. Storage area networks (SANs), remote locations, disaster recovery. Finisar s UltraSpan ROPA 3U amplification terminal is an FPGA and micro processor-controlled unit for providing pump power to a remote EDF placed 80-120km away. The unit features six pump laser drawers providing up to 1.6W of pump power in the 1420-1490nm band to a fiber line. The amplifier also features automatic power reduction (APR) based on multiple independent laser safety mechanisms. This allows both the amplifier to be classified as class 1M laser products (according to IEC 60825-1, and CDRH 21 CFR 1040.10) with respect to eye and skin laser safely of the operating personnel, and also protects optical and electronic gear deployed along the lines. The same mechanisms are also used for alerting system management upon line deterioration and reduction in pump power reaching the remote passive EDF unit. The amplifier includes two redundant and hot-swappable 48VDC power supplies, as well as a hotswappable cooling fan unit. The unit may be controlled via the simple network management protocol (SNMP) through a standard Ethernet RJ45 connector, or using an IP based GUI. Finisar Corporation 2014 Page 1

Optical Specification Specification Unit Min. Typ. Max. Notes Signal Wavelength range nm 1532 1566.5 Optimal ROPA performance (determined by the remote EDF unit) is typically 1545-1562nm Pump Wavelengths nm 1425, 1435, 1475, 1485 Composite Pump Power at max power mode mw 1600 2000 Power in the 1470-1490nm wavelength range after 22dB fiber loss for 0.2dB/Km fiber dbm 6 Raman gain db 22 Signal insertion loss db 1.5 2 Signal Input Power Range dbm -45 +5 Accuracy for all detectors db -0.5 0.5 Raman PDG db 0.3 PDL db 0.2 PMD ps 0.2 Laser Safety 3U unit Optical Connections Class 1M based on: ASE in the 1500-1520 band ASE @ 1529nm Back reflection in pump band Micro switch protection Time from eye safety occurrence to shut down < 50msec The ROPA is equipped with three Optical ports, as described in the table below (Optical connectors: E2000 for Line port and LC for other ports): Port Line Output Monitor Description This port has an E2000 high power connector. Pump power is launched through this connector into the optical transmission line. The signal enters the ROPA amplifier from the transmission line through this port. The signal exits the ROPA through this port. Used to monitor the signal exiting from the output port (1% tap) Finisar Corporation 2014 Page 2

Electrical Specification Parameter Unit Min. Typ. Max. Supply Voltage V -76-48 -36 Power Consumption W 100 155 Supply Current @48V Supply A 4 Block Diagram Finisar Corporation 2014 Page 3

Example GUI A typical ROPA GUI snapshot can be seen in the figure below. The easy to use GUI is web-based and can be accessed using internet explorer by simply entering the IP address of the ROPA unit. Finisar Corporation 2014 Page 4

Mechanical Specifications The following drawing shows the Raman s width, height and length dimensions. Environmental and Qualification Parameter Operating Temperature -5 C to +55 C Operating Humidity 5 to 85% Storage Temperature -40 C to +85 C Storage Humidity 5 to 95% Value/Range Qualification ETSI, NEBS Level 3 Laser Safety Class 1M* * Class 1M products are not hazardous under normal circumstances, but may pose an eye hazard when the laser output is viewed with certain optical instruments (for example eye loupes, magnifiers and microscopes) within a distance of 100 mm Finisar Corporation 2014 Page 5