Octalarm-T: the latest in future-proof industrial alarm diallers

Similar documents
USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

User manual Octalarm-IP

SMS GSM Alarm Messenger

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

System. For a better understanding of this product, please read this user manual thoroughly before using it.

MOBILE CALL GSM Alarm System User s Manual

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Cold chain monitoring technologies. Facility monitoring

Memcom Emergency Telephone

Ontech GSM 9040/50. Reference Manual English -1 -

PiSector GSM Cellular Wireless Alarm System

EXICALL EN70 EXICALL EN70MR EXICALL EN70-ATEX

with internal sensor (channel 1) with an external sensor (channel 2) A-Editor software, Professional AK20 version (not for version AK4)

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL

SC-F3G User Manual 1.0

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Sentient. Downloader Manual D4854

Security GSM Alarm System

JA-63 Profi User manual

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Monitoring Solutions

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

600 Range Dialer Installation Manual. Version 1.0

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Mobeye CM2410 GSM fire alarm communicator

IRIS Touch Firmware Enhancements and Additions from Version to Version

ALARM SYSTEM USER S MANUAL Rev

DiaLog Elite. Quick Reference Guide. Remote Monitoring, Control and. Alarm Notification System. # Enter. 1 Prog. 2 Run. 5 SpkrPh. Ack. Arm.

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

EVOSAFE-SERIES TM ULTRA-LOW TEMPERATURE FREEZERS

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

IRIS Touch Quick Installation & Maintenance Guide. Version 1.6

ADVISOR CD User Manual. Software from version: V

InvisiFence User Manual

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.

Solution 880 Operators Manual. Issue 1.00

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

CG500SKE SKYEYE GATEWAY USER MANUAL VERSION OCTOBER Disclaimers and Copyright

Security Alarm Systems

SI120 Guarto Easy I. Alarm system. Fire & Security Products

BURGLAR ALARM PANEL BS-468

3 User s settings. 3.3 Internal clock setting

Laboratory Refrigerator/Deep Freezer TC 802

CE818. User Manual. Made in Italy M1.5.1-H2.0-F1.41-S1.41-ENG

IC60 Sintony 60 Intrusion Control Panel

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

DS7400Xi Addressable Control/ Communicator

EasyAlarm ELEVATOR LEITRONIC AG

Chromatographic Air circulated Refrigerator, two-door TC 603

Operation Manual For model CM706E

DSE ELECTRONIC SIRENS Advantages & Functions

STRIKE GUARD DELIVERS:

wireless. web-based. worthy of the name RACO.

Silencing an Alarm All/Perimeter and Home/Away Systems. Area Systems. What to do when a trouble tone is sounding

Solution 4+4 Operators Manual ISSUE 1.25

VISTA 48DLCT HONEYWELL SECURITY

Intelligent Wireless GSM Alarm System

Mobeye is a Dutch manufacturer of GSM alarm and security products. Mobeye is

INC. DESIGN AND INTEGRATION OF ADVANCED SYSTEMS. Multipli Cité REMOTE WATER TREATMENT MANAGEMENT SYSTEM

Solution F2. Fire Alarm Control Panels one step ahead.

Software Solutions FOR THE TELECOMMUNICATIONS INDUSTRY CTS ALARM SOLUTION

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

USER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

IRIS Touch 200 Range Dialler Installation Manual. Version 1.4

With Magictrl, you can control MatiGard anytime & anywhere via your smartphone, even without data network.

Lone Worker Duress Security Hazard Zone Remote Area Health Care DURESS & SAFETY TECHNOLOGIES I N T E R N A T I O N A L

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

Chromatographic Air circulated Refrigerator, two-door TC 603

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

arm wire free solutions nurse call personal security fire alarms

SafeLine SL6 THE NEXT GENERATION OF

GSM RFID VOICE Alarm System

PREVENTIVE PROTECTION PROTECCIÓN PREVENTIVA

NESS 5000 SERIES DIALLER

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

Instructions manual. By-alarm. By-alarm Manager software

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

LIGHTNING PROTECTION SYSTEM

1. Introduction. 2. Product overview

Communicator. User & Installation Manual

GLOBAL. InstallatIon & operation manual

SMART HOME SECURITY. Dual Network Communicating Alarm System with RFID INVINCIBLE. Instruction Manual. Customer Helpline

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

RACO's Verbatim Gateway keeps you in touch, and in control, no matter where you are.

Intelligent Security & Fire Ltd

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

Transcription:

Octalarm-T: the latest in future-proof industrial alarm diallers Companies are becoming increasingly reliant on computers and technical equipment. Meaning you have to take steps to guarantee continuous operation and prevent production stoppages. The Octalarm-T from Adesys is specially designed and produced for just this. The Octalarm-T alarm dialler is ideal for today's automated environments, insuring the uninterrupted flow of your operations and the reliability of your equipment. This latest generation of alarm diallers has been developed in close consultation with users and insurance companies. The Octalarm-T oversees your entire company Who'll look after your business when you're away? Who'll be monitoring your computers and technical equipment while you're asleep? The Octalarm-T handles it all. With up to 16 alarm inputs, no area in your company escapes the Octalarm-T's watchful eye. And should there be an emergency, a bell or buzzer instantly sounds the alarm. The alarm signal can also be routed to your phone or pager if you like. The Octalarm-T interfaces with most types of pagers. The alarm signal can even be transmitted via SMS (Short Message Service) to GSM phones, giving you peace of mind. Octalarm is manufactured in the Netherlands by Adesys pioneers and leaders in the field of remote communications.

The Octalarm-T reaches you anytime, anywhere You can enter up to ten phone or pager numbers to receive alarm signals. If the Octalarm-T gets no reply or a 'busy' signal, it calls the next number in the order of priority that you specify. The system continues making alarm calls until the signal is accepted or deliberately reset. You can choose a number of reset procedures. Alarm status can checked by phone at any time If you've been unavailable for a while and you want to know if there's been an alert during that time, all you have to do is dial the Octalarm-T number. Within seconds you'll receive the current alarm status of all connected equipment. Depending on the version, this is done by a coded tone or a voice message recorded by you. Local alarm calls The Octalarm-T has a built-in buzzer and a two-line display for indicating alarm signals at your company. This gives all the information you need to take prompt and appropriate action. A siren and flashing light are optional extras. After resetting the buzzer, the flashing light remains active. It is only turned off when all alarms have been dealt with. The Octalarm-T is loud and clear - even from a distance Depending on the version you have, two options for alarm calls by phone are available: an easily recognized tone or your own previously recorded voice. For signals via pager, the Octalarm-T has pre-programmed report codes for each alarm channel. You can set these the way you want. Depending on your pager, you can select coded tones, numerical codes or text messages. Virtually all types of pager, message service or GSM phone can be reached. If you like, the Octalarm-T can call an alert station controlled by you. Even your power supply is monitored The Octalarm-T has a range of features. One is the monitoring of your valuable equipment. Another one that's just as important, is the monitoring of the power supply. If this cuts out, the Octalarm-T immediately switches over to an emergency battery. And follows it with a full alarm procedure. If the battery's almost up, the Octalarm-T will even report that. And how about self-monitoring functions like periodic battery tests and 'telephone line signalling'? A broken telephone line immediately results in a local alarm.

User-friendly operation The Octalarm-T is particularly easy to adjust. All information is shown clearly in a step-by-step fashion. You can sit back and relax. The user-friendly set-up is already pre-programmed. Any adjustments can be made using the central control panel. Remote switching via handy relay connection An additional port is available for connecting a relay switch. This can be used to restart an alarm installation, switch a ventilation unit or burglar alarm system on or off or to release an access door. All by phone. This relay switch is a standard feature of the Octalarm-T2, T4, T8 and T16. Monitor and control your system- anytime, anywhere Via standard, ISDN or GSM networks With the Octalarm-T you don't have to rely on a particular type of connection. It's suitable for both analogue and ISDN networks*. The choice is yours. You have no phone line at all? No problem. The GSM type gives you an extremely reliable connection via the mobile network. Connecting is simple: slot in your SIM card, input your number and you're ready. The ideal solution for monitoring mobile equipment or sites that don't have the necessary infrastructure. *The Octalarm-T1 is only available for analogue networks.

Practical information All external wiring linked via connector sockets Alarm contacts connected directly to the Octalarm-T or via Sensornet. One two-core low-voltage cable runs along all connected cables (max. length 1000 meters). System recognizes active input ports through coded connecting blocks at each contact Built-in power supply Emergency battery is maintenance-free and automatically checked and charged Programming is done through the easy-to-use control panel Models T2, T4, T8 and T16 can be programmed on or off site using a PC or laptop with a modem connection Extensive testing options System speaker allows you to listen in during test alarms (T2, T4, T8 and T16 models only) Data-logging of the last 50 alarm signals and program modifications for later analysis Extensive protection against lightning Quality checks on toughness and durability during the production process Self-testing functions insure extreme reliability Future-proof design includes space for program-updates and advances in communication technology Adesys BV: functional electronics Adesys has specialized in electronics for a range of advanced applications since 1983. Our product range is just one of our strengths. For years we've been marketing a broad selection of telephone alarm systems for use in greenhouse produce, agriculture and industry. Our Octalarm-Tand Modalarm-T series are brand leaders in the Netherlands. Thanks to their advanced technology, these alarm systems guarantee flexibility and security for your business. We pride ourselves on our special products. We have extensive expertise in a broad cross-section of market sectors. Because of this we know and recognize specific problems. And this translates into sound electronic designs. This doesn't just mean complete products. They may also be part of other products. Our special products are completely exclusive of course. In-house Production All Adesys' products are manufactured in-house. Both standard and tailor-made equipment. Our hardware and software departments are always ready to make fast and expert adjustments to standard products to fit your specific needs. Direct contact and clear agreements, both internally and with our clients, play an important part in this. Before delivery, each product undergoes an extensive testing procedure. First a production trial followed by a wear and tear check, a durability test and then a final test. Everything has to meet Adesys' high-quality standards. A complete in-house program that's the foundation for fast results and functional electronics. adesys bv Molenweer 4, 2291 NR Wateringen Postbus 60, 2290 AB Wateringen Telefoon +31 (0)174 296 389 Telefax +31 (0)174 293 807 E-mail: info@adesys.nl Internet: www.adesys.nl

Summary of technical options TYPE T1 T2 T4 T8 T16 ALARM INPUTS number of alarm inputs 1 2 4 8 16 may also be connected via Sensornet (4 / 8 alarm inputs using one 2-core cable) # alarm delay adjustable per input (1 sec - 99 min) TELEPHONE ALARM number of call numbers 10 10 10 10 10 selection order of call numbers adjustable per input ## adjustable report delay for phone signal (1-99 min.) signal to coded tone, numerical and alphanumerical pager signal to telephone with coded tone / self-recorded message / signal to mobile GSM phone / via Short-Message-Service (SMS) / / / / / signal to alert station signal codes and report texts adjustable per alarm input reset procedure adjustable per call number (reset during signal or by return phone call) waiting period (1-99 min.) / reset code (max. 4 digits) adjustable per call number / / / / / fully automated restart of report procedure after adjustable time period (1 min. - 20 hours) requesting alarm status via telephone line, signal via coded tone / self-recorded message / telephone line monitoring, with local signalling LOCAL ALARM incorporated alarm buzzer with adjustable volume outputs (12VDC) for external buzzer (energizing and de-energizing) / flashing light / / / / / adjustable start- and stop condition for built in buzzer and external signals indication of cause of alarm in display, text adjustable NIGHT MODE for switching local and telephone signal procedures, can be externally activated EMERGENCY SUPPLY supply voltage monitoring, with local and phone signal as default built-in maintenance-free emergency battery (operating 4-15 hours) phone signalling of empty battery / protection against battery over-discharge / / / / / automatic monitoring of battery condition / local- and phone signal on battery failure / / / / / permanent memory for all adjustments, (incl. recorded messages) ADJUSTMENT AND OPERATION adjustment via control panel with menu-controlled display keyboard blocking with access code test functions / listening-in via phone line during testing / / / / / RS-232 connection for adjustment and programming via PC remote programming via modem (with access code) CONNECTIONS input for external reset key / activation of night mode / / / / / output for relay (12VDC) to be switched on remotely) permissible load of external buzzers, flashing light and relay to be switched on remotely 150mA in total telephone connector with preference circuit for current conversations override built in protection against excess voltage (damage by lightning) MISCELLANEOUS incorporated Hayes-compatible modem reliable alarm across ISDN lines / GSM network / / / / / data-logger for last 50 alarm reports and program modifications second RS-232 connection, function later to be defined adjustment to client specifications supply voltageg 205-245 VAC, 50-60 Hz power distribution 4-9 Watt dimensions 255 x 171 x 58 mm = standard # = inputs 1-8: always via direct connection = optional inputs 9-16: always via Sensornet = not available ## = selection order adjustable per 2 inputs The policy of Adesys is aimed at continues improvement of products. Therefore Adesys remains the right to change specifications without notice.