F220-B6PS/M. Installation Guide. Addressable Detector Bases

Similar documents
D250A/D253/D261AW/D280A/D290 Series

D7044. Installation Instructions Multiplex Single Input Module

D7053. Installation Instructions Multiplex Input/Output Module

D7052. Installation Instructions Multiplex Dual Input Module

DS7465i. Installation Instructions. Input/Output Module

Multiplex Eight Input Remote Modules

Notification Appliance Circuit Module

Addressable NAC Output Module D327A

Annunciators, 8 LED. D7030X, D7030X-S2, and D7030X-S8. Installation Manual

D326A/D334A/D339A. Installation Instructions. Point Contact Modules

FMR Installation Instructions. Addressable Fire System Controller

Duct smoke housings, 4-wire D341/D341P and D342/D342P

Duct smoke housing, 2-wire D340/D340P

D7050DH. Installation Instructions. Multiplex Photoelectric Duct Smoke Detector

Battery charger modules

SPEC SHEET. Simple Expansion Solutions ZONE EXPANSION MODULES: SINGLE AND MULTIPLE POINT

Remote NAC Power Supply D7038

RF280THS. Installation Instructions Wireless (RF) Photoelectric Smoke Detectors

Conventional Smoke Detectors KFAPO

These instructions detail procedures to follow in order to avoid damage to equipment.

Operation and Installation Guide. Zone Expansion Module D8125

Installation Instructions Model HZM

D9412GV2/D7412GV2. Approved Applications Compliance Guide. Control Panels

IDP-Zone-6 Six Zone Interface Module

D8125MUX. Operation and Installation Guide. Multiplex Bus Interface

Control Panels D9412GV4/D7412GV4/D7212GV4. Approved Applications Compliance Guide

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

Booster Power Supply Manual

MMF Six Zone Interface Module

MANUAL RESET ALARM RELEASE

D285DH. Installation Instructions Photoelectric Duct Smoke Detector

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

MANUAL RESET ALARM RELEASE BOX

Photo Beam 5000/3000 Series Heater. en Installation Guide

D296/D297. Installation Instructions Long-Range Beam Smoke Detectors

Control Panel. D9412GV4/D7412GV4 v2.00. en UL Installation Instructions

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

D343. Installation Instructions. Air Duct Smoke Housing

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

Multiple Input and Output Modules

D7024 Fire Alarm Control Panel

FireNET Plus Wiring Instructions

MO144. Operators Guide. Universal Timer Module

Conventional Releasing Control Panel

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

D9412GV2/D7412GV2. Approved Applications Compliance Guide. Control Panels

FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE. Field Charger/Power Supply

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

Fire Control/Communicator

Model 17A00 Expansion Enclosure

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

Concerns: Affects: Dated: June 12, SECTION 1: GENERAL Scope Work Included... 3

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

Commercial Series TriTech Motion Detector. Reference Guide

DS7400Xi Addressable Control/ Communicator

1400 Direct Wire Ionization Smoke Detector

SC-6 Six Supervised Control Module

UEI-1 UNIVERSAL END-OF-LINE / ISOLATOR TESTER

MANUAL RESET ALARM RELEASE

TrueAlarm Smoke Detectors

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

D1255RB/D1256RB/D1257RB

D2071A. Operation & Installation Guide Fire Alarm Control Panel

TrueAlarm Analog Sensing

Conventional Fire Alarm System 2014 V1.2

Protecting Lives and Assets FPD-7024 Fire Alarm Control Panel

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

DS160/161 Request To Exit PIR sensors Installation Instructions

SIGA-CC1 Single Input Signal Module Installation Sheet

Print Specification. Publication. Instructions. Specific requirements. General requirements

Bosch EVAX System - High-rise Applications

RELEASE DEVICE CONTROLS

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for models:

Installation Manual. Detector Bases: PAD100-IB, PAD100-RB & PAD100-SB

Installation Guide for models:

Control Panels B5512/B4512/B3512. en UL Installation Instructions

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

PAD100-6DB & PAD100-4DB PAD100-PD

Multi-Application Peripherals and Accessories

Installation Manual: PAD100-DUCTR Analog Addressable Duct Detector

RM-1 Series. Remote Microphones. (RM-1, RM-1SA) Document Revision B RM-1 RM-1SA. RM-1 on ADP-4 dress panel. RM-1SA in a CAB-RM or CAB-RMR

SECTION FIRE ALARM SYSTEMS

MR-2602 Two Zone Fire Alarm Control Panel

PN: 51883:D ECN Field Charger/Power Supply FCPS-24FS6 FCPS-24FS8. Document # /14/05 Revision: D

Independent Zone Control (I.Z.C.)

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

TECHNICAL DATA OBSOLETE

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

Transcription:

F220-B6PS/M EN Installation Guide Addressable Detector Bases

F220-B6PS/M Installation Guide 1.0 Overview 1.0 Overview These instructions cover the installation of the B6PS/M Addressable Detector Bases in an addressable system. The addressable system is controlled by a D9412G/D7412G or later 12 V control panel with a D8125 POPEX Module and 12 V or 24 V auxiliary power or a D9124 24 V Fire Alarm Control Panel (FACP). The F220-B6PS works with either 12 or 24 V where the F220-B6PM only works with 24 V (refer to Section 6.0 Specifications on page 7). The B6PS/M, with its built-in POPIT, provides individual addresses on the FACP data expansion circuit. These bases accept the F220 Series Photoelectric Smoke Detector and Heat Detector Heads. When using the B6PS/M with the F220 Series Detectors, these bases provide a Chamber Check trouble indication to the control panel through the POPIT Bus. The trouble indication appears at the control stations as a Fire Trouble. When using these bases as replacements in a system controlled by control panels other than those identified such as the D8112, D7212B, or D7212B1, follow the control panel s address (point assignment) setting instructions and set the base address switch (0) to the ON position. Chamber Check is a registered trademark of Bosch Security Systems in the United States. 2.0 Mounting Install, test, and maintain the B6PS/M according to these instructions, NFPA 72 standards, local codes, and the Authority Having Jurisdiction (AHJ) in your area. Failure to follow these instructions can result in the detector not indicating an alarm. Bosch is not responsible for improperly installed, tested, or maintained detectors. 1. Select a mounting location according to the Smoke Detector Technical Service Note (P/N: 31347). 2. Run all system wiring to the base locations first. 3. Mount the base using the two oblong mounting holes. 4. Tighten the base to the mounting surface. 5. Connect the wiring to the base. Depending on the local regulations, you can surface mount the base using anchors, mollies, or wing nuts. You can also mount the base on 4 in. (10 cm) octagonal electrical boxes or single-gang switch boxes. Ensure the volume of the electrical box you use is adequate to accommodate the number and size of conductors as specified by the National Electrical Code (NEC) or any local regulations having jurisdiction. 3.0 Wiring Table 1: Bases and Wire Gauges Number of Wire Gauge Bases in Circuit 22 AWG (0.8 mm) 20 AWG (1.0 mm) 18 AWG (1.1 mm) 16 AWG (1.3 mm) 1 to 70 1822 ft (597 m) 2898 ft (950 m) 4608 ft (1510 m) 7327 ft (2402 m) 70 to 80 1594 ft (523 m) 2536 ft (831 m) 4032 ft (1322 m) 6411 ft (2102 m) 81 to 90 1417 ft (434 m) 2254 ft (739 m) 3584 ft (1175 m) 5699 ft (1868 m) 91 to 100 1275 ft (418 m) 2028 ft (665 m) 3225 ft (1057 m) 5129 ft (1681 m) 101 to 110 1159 ft (380 m) 1844 ft (605 m) 2932 ft (961 m) 4663 ft (1529 m) 111 to 120 1063 ft (349 m) 1690 ft (554 m) 2688 ft (881 m) 4274 ft (1401 m) 3.1 Terminal Connections Do not twist the wires or loop them around the terminals. Cut, strip, and insert the in and out wires for terminal connection as individual ends. 2 Bosch Security Systems, Inc. 11/10 4998149982-04

. Figure 1: Connect the power loop to the control panel s switched auxiliary power. When using a separate supply, connect the negative side to the control panel ground. 1 Terminals B2 B1 A1/A2 + + C 2 F220-B6PS/M Installation Guide 3.0 Wiring 3.2 Wire Size The B6PS/M can accept any solid wire size from 12 AWG (2.0 mm) to 24 AWG (0.6 mm). The minimum wire size required by the bases is determined by the maximum number of bases used and the maximum distance from the FACP to the most remote base. For 12 AWG (2.0 mm) and 14 AWG (1.6 mm) wire, use the specifications for 16 AWG (1.3 mm) wire. Refer to Figure 2 and Figure 3 on page 4 for wiring multiple bases. Use a at least 18 AWG (1.0 mm) wire for Underwriters Laboratories. Inc. (UL) Listed requirements. Use the B6PM with the F220-B6 two-wire base for the F220-P/PTH/PTHC/135/135F/190F Detectors (refer to Figure 4 on page 4). 1 - B2 (+) and B1 (+) Terminals 2 - A1/A2 and C Terminals Figure 2: B6PS Base Wiring 1 1 1 (+) 2 A1/A2 C A1/A2 C A1/A2 C (-) 3 (-) (+) 1 - B6PS 2 - Switched Auxiliary Power 12 VDC or 24 VDC 3.2.1 Wiring the B6PM For the B6PM: 1. Each base can supervise up to 19 additional twowire detectors. 2. Wiring to the most distant slave detector cannot exceed 500 ft (52 m) with a wire that is 18 AWG (1.1 mm) or greater. 3 - POPIT Bus 3. Connect the 3 kω end-of-line (EOL) resistor Bosch P/N: 15-03130-007 (F.01U.008.725) across the last base, Terminals A1/A2, and B1. When not using slave two-wire detectors with the B6PM, connect the 3 kω EOL resistor across the B6PM Terminals A1/A2 and B1. 4. Wire Terminal C to use the dirty detector feature with the slave two-wire bases. Do not enable the clean-me feature on the F220s. Bosch Security Systems, Inc. 11/10 4998149982-04 3

F220-B6PS/M Installation Guide 3.0 Wiring 3.2.2 Wiring the B6PS/M For the B6PS/M, connect the power loop to the control panel s switched auxiliary power. When using a separate supply, connect the negative side to the control panel negative or POPIT Bus. Figure 3: B6PM Base Wiring 1 - B6PM 2 - Switched Auxiliary Power 24 VDC 3 - POPIT Bus 4 - EOL or connect F220-B6 Conventional Bases Figure 4: B6PM Wiring with Multiple Bases 1 - B6PM 2 - F220-B6 Base 3 - Switched Auxiliary Power 24 VDC 4 - POPIT Bus 5 - Connect C Terminals together to indicate Dirty Detector 6 - EOL on Last Base (B1 to A1/A2) 4 Bosch Security Systems, Inc. 11/10 4998149982-04

. F220-B6PS/M Installation Guide 4.0 Base POPIT Addresses 4.0 Base POPIT Addresses Figure 5: Address Switches Each detector base has a specific address point that is determined by setting the seven DIP switches on the detector s base. The base address number does not depend on the base location in the circuit. When using a D9412G/D7412G or later control panel or a D9124 FACP refer to Table 2 to set each base address. If adding the base to an FACP version B1 or earlier, set switch 0 to ON and leave all other switches off. Figure 5 shows a magnified view of the address switches. 5 4 3 2 1 6 1 - Terminal 1 (POPIT Bus +) 2 - Terminal 2 (POPIT Bus -) 3 - Terminal 3 (not used) 4 - Terminal 4 (not used) 5 - Terminal 5 (- auxiliary DC supply) 6 - DIP Switch Table 2: Addresses Switch Switch Switch Point 0 1 2 3 4 5 6 Point 0 1 2 3 4 5 6 Point 0 1 2 3 4 5 6 009 029 049 010 030 050 011 031 051 012 032 052 013 033 053 014 034 054 015 035 055 016 036 056 017 037 057 018 038 058 019 039 059 020 040 060 021 041 061 022 042 062 023 043 063 024 044 064 025 045 065 026 046 066 027 047 067 028 048 068 Bosch Security Systems, Inc. 11/10 4998149982-04 5

F220-B6PS/M Installation Guide 5.0 PAM-4 Relay Module Wiring Table 2: Addresses (Continued) Switch Switch Switch Point 0 1 2 3 4 5 6 Point 0 1 2 3 4 5 6 Point 0 1 2 3 4 5 6 069 089 109 070 090 110 071 091 111 072 092 112 073 093 113 074 094 114 075 095 115 076 096 116 077 097 117 078 098 118 079 099 119 080 100 120 081 101 121 082 102 122 083 103 123 084 104 124 085 105 125 086 106 126 087 107 127 088 108 128 Reserved = ON Note: For Points 129 through 248, add 120 to Point Numbers 009 through128. For example, adding 120 to Point 009 is Point 129 Address (switch setting). 5.0 PAM-4 Relay Module Wiring Table 3: PAM-4 Relay Module Wiring Wire Lead Color Description Contact Set Red Positive N/A Black Negative N/A White Alarm Sense N/A Blue Normally Open A Green Common A Yellow Normally Open B Purple Common B Orange Normally Closed B Only use the PAM-4 Relay Module with 24 V systems. The operating voltage of the F220-B6PS, when used with the PAM-4 Relay Module, is 18.9 VDC to 28 VDC. 6 Bosch Security Systems, Inc. 11/10 4998149982-04

F220-B6PS/M Installation Guide 6.0 Specifications. Figure 6: PAM-4 Relay Module Wiring to B6PS/M 1 - B6PS/M 2 - Black wire (to Terminal 5) 3 - Red wire 4 - PAM-4 6.0 Specifications Table 4: Specifications B6PS with Head B6PS with PAM-4 Relay Module and Head Auxiliary Power Voltage Range 9.6 VDC to 28 VDC 18.9 VDC to 28 VDC Idle Current 2.5 ma 18.5 ma Alarm Current 35 ma 51 ma B6PM with Head* B6PM with PAM-4 Relay Module and Head* Auxiliary Power Voltage Range 18.9 VDC to 28 VDC 18.9 VDC to 28 VDC Idle Current 13 ma 29 ma Alarm Current 39 ma 55 ma * Current ratings are based on a B6PM with 19 slave detectors. Bosch Security Systems, Inc. 11/10 4998149982-04 7

Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY, 14450 USA www.boschsecurity.com Bosch Security Systems, Inc., 2010