Mounting plates for data connection caps

Similar documents
HTF28 - HTF48 - HTF63. Crimping tool for spade plugs and spade sleeves. with open or pre-rolled crimping claw

Around the cable. Pressing and crimping.... convincing solutions

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

Precision Crimp Wrenches

CRIMPING PLIERS. 00 Crimp Grip Pliers A. EAN mm Pliers Applications. Capacity. Article No.

Tools & Test Equipment

SECTION COMMUNICATIONS HORIZONTAL CABLING

More Precision. eddyncdt // Eddy current sensors for displacement and position

Fiber Optic Products Catalog

MT-RJ Optical Fiber System Field Testing

Product Specification CAT 6 UNSHIELDED PATCH CORDS

CRIMPERS CRIMPERS. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

LCS 2 THE CATEGORY 6A GUARANTEE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

About Us. Who We Are Our Mission Our Products USA DAVIS LEGEND. Chicago

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

CRIMPING PLIERS. 00 Crimp Grip Pliers A. Capacity Article No mm Pliers Applications

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

Tools for other contacts Tools for FOC contacts Crimping machine TK-M Crimping machine TC-C

Category 5e Products

AMPTRAC Intelligent Infrastructure Management System (IIMS)

Arteor TM LCS2 Cat. 6A UTP RJ 45 socket

Universal Connectivity Platform

Compact Module. Category 6A FTP Cabling System 1.1

Amphenol LTW Technology Co., Ltd. Amphenol LED Market. Innovation in Waterproof Solution

4120 Fire Alarm Network Reference

Arteor TM LCS2 Cat. 6A STP RJ 45 socket

Infrastructure components for PROFIBUS DP

RoboFeed 3004w, Aristo RoboFeed Spare parts list. The wire feed unit is renamed: Edition

INTERLINKS - TLC CREATIVE SOLUTIONS

Amphenol Renewable Energy Market

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket

PROFESSIONAL PRICELIST

A. Capacity mm² AWG g A burnished insulated terminals and plug connectors with multi component grips

Industrial Connectivity Products. Cabling and Connectivity for Hash Environments

Luminaire for traffic coordination Traffic Light Counter 1S2-TL-N Trafic Lider

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

FIBER OPTIC CONNECTOR CLEANERS

Amphenol Renewable Energy Market

Universal Connectivity Platform A Modular Approach to Infrastructure Design

commercial-type cabling and connectivity products into the industrial landscape.

PROJECT DATE FLANGE FINISH

Undercarpet Cabling Products Undercarpet Power, Voice and Data Distribution

Tools. Contents Tools for contacts Han D Tools for contacts Han E Tools for contacts Han C

Fiber Optic Connector Cleaning Solutions

800 MHz US 2 NMR system

Heidelberger Straße Berlin Germany. phone +49(0) fax +49(0)

SBI INFRA MANAGEMENT SOLUTIONS PVT. LTD.

ILLUMINATORS SIL SERIES INDUSTRIAL ILLUMINATORS

AMP NETCONNECT 2010 Product Catalog Index

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Taxonomies, Classifications, and Categories NEMA RATED TURNLOK PLUGS, CONNECTORS, & RECEPTICLES Combo Telephone Tool

Ledinaire Batten Simply great LED

Tools. Contents Tools for contacts Han D Tools for contacts Han E Tools for contacts Han C

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards.

Line Array Systems. Vertus

SECTION COMMUNICATIONS PATCH CORDS, STATION CORDS AND CROSS CONNECT WIRE

Phone: Fax: Web:

PRODUCT REPRINT JANUARY Product Code 70060

MBCE-110/230FR Flame Sensor Module

Industrial Ethernet Products. RoHS. Ready

SIMATRIX NEO Modular Video Matrix

Battery Interconnects

Telephone and Data Structured Wiring

TOKISTAR LIGHTING INSTRUCTION MANUAL. Advantage Series. Xenon Lamp. Socket. Side View. 2.4 O.C. (60 mm) 3 O.C. (75 mm) 4 O.C. (100 mm) 6 O.C.

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

New features make cooking a greater pleasure than

Parts and Service Manual

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

818 Series Low-Power Detectors

LexCom 19" patch panels. Put your hands on innovation

CABLES FOR ALARM AND SAFETY SYSTEMS

Testing Accessories. Test PaddleS. Test Paddle Attachment Plugs Insulated Socket Wrench Jumper Strips Test Lead Kit

STAND ALONE DRYER BASE. Parts Manual

Cat 6 Unshielded Patch cords

SOHO X. 4" Two-way passive system

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

Housing. Mounting. Warranty. Listing

The Next Generation of Data Communicatons Solutions

Pole Mounting System Installation & Certification Manual

MULTI-STAGE, MULTI-FUNCTION AND MODULAR INTERMEDIATE VACUUM MODULES SERIES MI

. SECTION CONTROL-VOLTAGE ELECTRICAL POWER CABLES

WELCOME. Elektronische Bauelemente GmbH

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

KIT CONTENTS Ref Qty Part Description Part Number

WELCOME. Elektronische Bauelemente GmbH

SERVICE PARTS for ECO353N

NEW. lighting management - stand alone detectors, power packs. Passage detection - Infrared technology. Detectors with power packs

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

/Oct/2014 Rev E

DETAIL SPECIFICATION

Applications Engineering Notes

Problem-solvers The Radiator Solution Range

AMP NETCONNECT Category 5E SL Shielded Cabling System. 1. General Description

GRS tacho. 1.GRS tachograph service parts

For all new Fibre Optic Lots Stages 41B to 80

Instruction Manual ID-442 Infrared Detector 442-1A Temperature Controller Preamplifier

HEATING SYSTEMS FOR MICROSCOPES

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

AD-230 Parts Manual. Phase 5 24 Vac

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

Transcription:

Mounting plates for data connection caps Ref.-No. 54... 1 Ref.-no. 54 OCS... 2 Ref.-no. 54 SC... 3 Ref.-no. 54-2 SC... 3 Ref.-no. 54 XLR-D... 4 Ref.-no. 54 XLR-S... 4 Ref.-no. 54-1 ACS... 5 Ref.-no. 54-1 WE... 6 Ref.-no. 54-2 ACS... 7 Ref.-no. 54-15 WE... 8 Ref.-no. 54-25 WE... 9 Ref.-no. 54-2 BNC 12.7... 10 Ref.-no. 54-2 BNC 9.7... 10 Ref.-no. 54-2 CXLR... 11 Ref.-no. 54-2 D15... 11 Ref.-no. 54-2 D25... 12 Ref.-no. 54-2 D9... 12 Ref.-no. 54-2 LWL... 13 Ref.-no. 54-4LWL... 13 Ref.-No. 54 Obturateur pour incorporations diverses Stand: Nov-08

Ref.-no. 54 OCS for 1 socket for OCS-system (Open Cabling System) make Telegärtner single module no. J00091A0007, shielded double module no. J00093A0009, shielded 2

Ref.-no. 54 SC for 1 Duplex-coupling, LWL, SC system, Amphenol, or Avaya (Lucent Technologies) (AT+T), or Tyco Electronics AMP Ref.-no. 54-2 SC for 2 Duplex couplings (optic fibre) LWL, SC system, Amphenol LWL, SC system, Avaya (Lucent Technologies) (AT+T) LWL, SC system, Tyco Electronics AMP 3

Ref.-no. 54 XLR-D for 1 XLR-socket (female) Ref.-no. 54 XLR-S for 1 XLR-plug (male) 4

Ref.-no. 54-1 ACS for 1 socket Reichle + De Massari freenet, freenet, classic system, shielded, no. R925370, Cat. 5e freenet, classic system, unshielded, no. R925371, Cat. 5e freenet, star system, shielded, no. R302372, Cat. 6 freenet, star system, unshielded, no. R302373, Cat. 6 for 1 SC-RJ module freenet, vision system, no. R30574 5

Ref.-no. 54-1 WE for 1 modular jack socket Qmax-series, modular, RJ 45 system, shielded, 3M, Cat. 6 modular RJ 12 system, unshielded, JUNG no. 6 WE, Cat. 3 modular, RJ 45 system, unshielded, JUNG no. 8 WE, Cat. 3 Highband-series, modular, RJ 45 system, shielded, Krone, Cat. 6 Compact-HK-series, modular, RJ 45 system, shielded, Krone, Cat. 5e Snap-in Connector LANmark-6 system, modular, RJ 45, shielded, Nexans no. 420.630, Cat. 6 modular, Keystone RJ 45 system, unshielded, Panduit no. KJ88.., Cat. 3 modular, Keystone RJ 45 system, unshielded, Panduit no. KJ588.., Cat. 5 modular, RJ 12 system, unshielded, RADIALL no. R280MOD804, Cat. 4 modular RJ 45 system, unshielded, RADIALL no. R280MOD805, Cat. 4 modular RJ 45 system, unshielded, RADIALL no. R280MOD807, Cat. 5 modular RJ 45 system, shielded, RADIALL no. R280MOD809, Cat. 5 modular, Keystone RJ 45 system, shielded, SIEMON no. MX6-KS..,Cat. Cat.6 modular, RJ 12 system, unshielded, Tyco Electronics AMP no. 216000-1, Cat. 3 modular, RJ 45 system, unshielded, Tyco Electronics AMP no. 216005-1, Cat. 3 6

Ref.-no. 54-2 ACS for 2 modular jack sockets Reichle & DeMassari freenet, classic system, shielded, no. R35252, Cat. 5e freenet, classic system, unshielded, no. R35251, Cat. 5e freenet, star system, shielded, no. R302377, Cat. 6 freenet, star system, unshielded, no. R302378, Cat. 6 for 1 SC-Compact 2-channel module LWL, freenet, vision system, no. R30575 7

Ref.-no. 54-15 WE for 1 modular jack socket Tyco Electronics AMP 110 Connect, RJ 45 system, shielded, JUNG no. 8 VGWE, Cat. 5e 110 Connect, RJ 45 system, shielded, Tyco Electronics AMP no. 0-1116515-1, Cat. 5e 110 Connect, RJ 45 system, shielded, Tyco Electronics AMP no. 0-1375117-1 SL 110 Connect, RJ 45 system, shielded, Tyco Electronics AMP no. 0-1375189-1, Cat. 5e SL 110 Connect, RJ 45 system, unshielded, Tyco Electronics AMP no. 0-1375190-X, Cat. 5e SL 110 Connect, RJ 45 system, shielded, Tyco Electronics AMP no. 0-1375188-1, Cat. 6 SL 110 Connect, RJ 45 system, unshielded, Tyco Electronics AMP no. 0-1375055-3, Cat. 6 Toolless Jack, RJ 45, system, unshielded, Tyco Electronics AMP no. 0-1116603-X, Cat. 3 Toolless Jack, RJ 45, system, unshielded, Tyco Electronics AMP no. 0-1116604-X, Cat. 5e Toolless Jack, RJ 45, system, shielded, Tyco Electronics AMP no. 1339015-1, Cat. 5e Toolless Jack, RJ 45, system, unshielded, Tyco Electronics AMP no. 0-1116605-X, Cat. 6 Toolless Jack, RJ 45, system, shielded, Tyco Electronics AMP no. 1339016-1, Cat. 6 LWL, MTRJ system, Tyco Electronics AMP no. 1278414-1 8

Ref.-no. 54-25 WE for 2 modular jack sockets Tyco Electronics AMP 110 Connect, RJ 45 system, shielded, JUNG no. 8 VGWE, Cat. 5e 110 Connect, RJ 45 system, shielded, Tyco Electronics AMP no. 0-1116515-1, Cat. 5e 110 Connect, RJ 45 system, shielded, Tyco Electronics AMP no. 0-1375117-1 SL 110 Connect, RJ 45 system, shielded, Tyco Electronics AMP no. 0-1375189-1, Cat. 5e SL 110 Connect, RJ 45 system, unshielded, Tyco Electronics AMP no. 0-1375190-X, Cat. 5e SL 110 Connect, RJ 45 system, shielded, Tyco Electronics AMP no. 0-1375188-1, Cat. 6 SL 110 Connect, RJ 45 system, unshielded, Tyco Electronics AMP no. 0-1375055-3, Cat. 6 Toolless Jack, RJ 45 system, unshielded, Tyco Electronics AMP no. 0-1116603-X, Cat. 3 Toolless Jack, RJ 45 system, unshielded, Tyco Electronics AMP no. 0-1116604-X, Cat. 5e Toolless Jack, RJ 45 system, shielded, Tyco Electronics AMP no. 1339015-1, Cat. 5e Toolless Jack, RJ 45 system, unshielded, Tyco Electronics AMP no. 0-1116605-X, Cat. 6 Toolless Jack, RJ 45 system, shielded, Tyco Electronics AMP no. 1339016-1, Cat. 6 LWL, MTRJ system, Tyco Electronics AMP no. 1278414-1 9

Ref.-no. 54-2 BNC 12.7 for 2 BNC-sockets with Ø 12.7 Ref.-no. 54-2 BNC 9.7 for 2 BNC-sockets with Ø 9.7 10

Ref.-no. 54-2 CXLR for 2 sockets CXLR-S/CXLR-D; PB 4/PS 4 Ref.-no. 54-2 D15 for 2 subminiature D-sockets,15-pole, D SUB 15 11

Ref.-no. 54-2 D25 for 2 subminiature D-sockets, 25-pole, D SUB 25 Ref.-no. 54-2 D9 for 2 subminiature D-sockets, 9-pole, D SUB 9 12

Ref.-no. 54-2 LWL for 2 couplings, LWL (optic fibre), ST, 2,5 mm bayonet nut connector (BNC Ref.-no. 54-4LWL for 4 couplings, LWL (optic fibre), ST, 2.5 mm bayonet nut connector (BNC) 13