Smoke Master SMPA Compact pressurisation system

Similar documents
Smoke Master SMPA Installation, operation and maintenance

Smoke Master SMIA Compact pressurisation and smoke exhaust system

Smoke extract fan SMHA HATCH

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

Unit heater with accessories

PFS Single stage axial fan The axial fan for modern boiler plants

ClimaFläkt. Chillers and condensing units

EU Air Handling Units with SEMCO EXCLU-SIEVE

Climatix LON communication with POL SNVTs for eq zone application v1.x

Climatix LON communication with POL SNVTs for Twin Wheel application v1.x

GLEC exhaust FAN. Air Comfort. Air movement. Duct & Box Fans

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans

DIF-OT Ceiling Filter. The optimized laminar airflow

Climatix Basic reference addresses for eq Fläkt application v1.x

TopMaster Air Handling unit. Technical data

MARINE APPLICATIONS MARINE» PRODUCTS AND SOLUTIONS FOR MARINE APPLICATIONS

CENTRIFLOW 3D. >> Installation and Maintenance. air comfort. CentriFlow 3D

TopMaster Air Handling unit. Installation instructions

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

SMOKE CONTROL - NEW DIRECTIONS

iq Star by Fläkt Woods Multi-service Chilled Beam Guide Star by Fläkt Woods

more than just a fan supplier more than just a fan supplier Axair Fans UK Limited

iq Star LYRA II chilled beam cassette

GLEB Kitchen exhaust fan

Cleaning doors. Good indoor air also means cleanability of ductwork

ECO ROOF FAN. A modern, energy-saving roof fan with a DC motor. INSTALLER Register the roof fan for an extended 5 year guarantee!

Mechanical Smoke Extract Shaft Systems

nzeb office building

recooler HP EQKR HEAT PUMP

Technical Information

REVIEW OF TECHNICAL STANDARDS AND CALCULATION METHODS FOR DIMENSIONING OF SMOKE AND HEAT CONTROL SYSTEMS IN CASE OF FIRE IN UNDERGROUND CAR PARKS

MECHANICAL SERVICES 101. Ian White

Instructions for the BASIC BCRW Fan, Sizes General

ROLL-DOWN FIRE DOORS AND SMOKE CURTAINS

IPSUM OPTIMIZATION SYSTEM» DEMAND CONTROLLED VENTILATION OVERVIEW

Fire damper ETPR Instructions for Installation, Operation and Maintenance 10/2016

TopMaster Air Handling Unit

technical specification smoke venting systems

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

iq Star LYRA II chilled beam cassette

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

Tunnel Systems. Design & Supply Metro Axial Fans. Tunnel Axial Fans. Jet Fans.Fans for Escape Tunnel System Components. Engineering Support

incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications

Air Management for Food Applications

Systemair product news - Fans NEWS

The Corona air inlet TECHNICAL SPECIFICATIONS

Snifter ATEX22 VERSION. User Manual. Distributor

Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS)

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

Product Information October (8) Orivent 51 in Itella, Pennala. Orivent 01 in Oriville factory, Orimattila

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

CARE GUIDANCE. Local Exhaust Ventilation (LEV) Systems for High Temperature Insulation Wool (HTIW) LEVEL 2 RECOMMENDATIONS ON BEST PRACTICE

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION)

Roof Fan DVG EC. Smoke extraction and daily ventilation in one!

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

Ceiling swirl diffusers

GOLD RX, GOLD RX 12 GOLD RX,

0.4 m 3 /s. Plastic and Steel cased fan Units. Round Fans. Latest EC Fan Technology. Compact and Powerful. Easy to install

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

Heating Systems. An ideal temperature in every pig house

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

LYRA » ENERGY EFFICIENT CASSETTE CHILLED BEAM AIR DIFFUSION LYRA

Lonworks Damper Interface Catalogue

KLIMA Active Chilled Beams

VERSO Air Handling Units

Halton Rex for Vario R6O - Variable air volume chilled beam

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

Safety - a full time job

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

TUNNEL FANS STANDARD AND HOT SMOKE

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

FIRE DEPARTMENT - RULES FOR FIRE PROTECTION IN AUSTRIA

Type VDW WITH LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH INDIVIDUALLY MANUALLY ADJUSTABLE AIR CONTROL BLADES

Demand-controlled Ventilation Leading edge products for demand-controlled ventilation

RAK THE OPTIMUM RANGE FROM REFCOOL THE ENERGY REVOLUTION. Industrial chillers - 0 to 200 kw

UNITES TERMINALES ET MINI CTA FIDJI

Aspirating Smoke Detection for Duct Monitoring

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Primo Hotel. General. Indoor climate units for hotel rooms

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Innovative solutions for air and climate technology. Air handling Climate ceilings Air distribution technology Fire safety products Chilled beams

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

½ CAUTION ½ DANGER. Getting to know the smoke detector. ARGUS Smoke Detector Single. Accessories. Operating instructions. For your safety A B C D E

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

Building Consent Application Compliance Schedule Information

Powrmatic PZN / PZN X Hot Water Heater

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

CE-marked ESAD - Smoke Control Duct System Installation instructions 08/2013

Top tip No. 21 Fireman s override

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

30 top tips to tackle HVAC challenges No.21 - Fireman s override

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Transcription:

Smoke Master SMPA Compact pressurisation system

Fläkt Woods FILO E 2009.07 2 All rights reserved.

Contents System overview...4 Design and operation...5 Technical specification...6 Electric and control equipment...7 Apartment air release path...9 Installation...10 Product code... 11 Fläkt Woods FILO E 2009.07 All rights reserved.

PRESSURIS. Fan unit SMPA System overview 1c 1a,1b or 1c 1b 2b/2c 4 SMPA-1 2a 1a Fan unit 2a, 2b or 2c SMPZ-2 SMOKE MASTER SMPA is an all-inclusive total solution for exit route pressurisation. The system has been designed and the components constructed to meet the E 12101-6 requirements. The system has been subjected to a variety of tests at Fläkt Woods own laboratories. SMPA has been designed for pressurisation of exit routes of different types, such as the stairwells of residential buildings, underground exit routes, and the exit routes from car parks. The SMPA-1 fan unit is available with three sizes which makes it suitable for use over a wide range of air volumes. Control unit PRESSURISATIO STADBY SERVICE MA FA O Due to its compact structure, the SMPA fan unit (SMPA-1) has small overall dimensions and, therefore, it is also suitable for a variety of renovation projects. In blocks of flats, the fan unit can be installed in the upper or lower part of the stairwell. An SMPA total solution comprises a smoke hatch integrated into the encapsulated fan unit, a control panel, and a control unit. The apartment air release solutions with spindle motors, smoke detectors, and control units are supplied by our partners. SMPZ- Control panel 4 SMIZ-4 Differential pressure transmitter Fläkt Woods FILO E 2009.07 4 All rights reserved.

Design and operation General The product development of the SMPA pressurisation system has accounted for the E-12101-6, (RIL 22-2007) requirements and different pressurisation classes. In practice, projects need to pay special attention to choosing the correct pressurisation class, because different pressurisation classes will result in very different pressurisation air flows. There are many things that affect the choice of pressurisation class, such as the size of the building and the instructions for exit. The pressurisation class should always be chosen in cooperation with the experts of the local fire department. The aim of pressurisation design is to create without delay a 50 Pa overpressure in the stairwell (exit route) in the event of a fire in an apartment. The pressurisation fan is automatically activated by a smoke detector in the apartment on fire. The smoke detector shall also automatically open the air release path (smoke extract window) in the apartment. The air release path shall have a minimum opening (free area) of 0.5 m2, if the air flow velocity through an open door is desired to reach 0.75 m/s. Dimensioning and quick guide Design and choose in cooperation with rescue authorities the suitable pressurisation class for the site. Select on the basis of the pressurisation class and the number of storeys the most suitable size from the SMPA product family. Please contact Fläkt Woods for expert consultation on the suitability of SMPA for the project. Pressurisation class A number of storeys SMPA Pressurisation class C number of storeys SMPA -8 040 8-12 050, 06 8-12 040, 050 12-06 12-050, 06 - - If the door of the apartment on fire opens, the system automatically increases the air flow so that it will reach a velocity of at least 0,75 m/s in the direction of the space on fire. Air flow criterion Air flow criterion Differential pressure criterion (doors closed) 2 2 2 1 0,75 m/s 10 Pa 50 Pa 1 Design conditions for pressurisation class C. 1. Door open, 2. Door closed,. Air release path. Fläkt Woods FILO E 2009.07 5 All rights reserved.

Technical specification Dimensions Safety switches Width b Height h Depth s Ø d X Y SMPA-1-040 721 571 70 400 514 87 SMPA-1-050 841 689 781 500 620 6 SMPA-1-06 971 819 780 600 77 6 Materials: Fan unit: The outer and inner casings are made of galvanized steel sheet and the shroud has 100 mm mineral wool insulation. The smoke hatches are made of galvanized steel sheet and insulated with mineral wool. Weights kg SMPA-1-040 90 SMPA-1-050 120 SMPA-1-06 170 Fläkt Woods FILO E 2009.07 6 All rights reserved.

SMPA COTROL UIT K0.4 21 22 24 K0. 41 42 44 4 5 7 8 9 10 11 12 1 14 15 16 17 19 20 21 2 24 25 L 2x1,5 4x1,5 2x0,8+0,8 2x1,5 2x0,8+0,8 12x1,5 SAFE 2 01 21 2 4 6 22 1 5 SI MU RU KEVI - + dpt 01 2x0,8+0,8 1 6 1 6 SD1 SD2 15 16 17 19 20 21 2 V1 W1 U1 M x400vac M M 2x28 VA 1X20VAC 1 6 2,2 kohm 2x0,8+0,8 SD max 2 COTROL PAEL WARIG APARTMET SMOKE EXTRACT WIDOW COTROL UIT 24V 24V APARTMET SMOKE EXTRACT WIDOW COTROL UIT 24V 24V OT SUPPLIED BY FLÄKT WOODS L Fan unit SMPA Electric and control equipment General: Every SMOKE MASTER SMPA system comes with the necessary electric and control equipment. The SMPA basic package includes the following electric and control equipment: control unit SMPZ-2 control panel SMPZ- differential pressure transmitter SMIZ-4 safety switches SMPA electric connection data System Pressurisation fan Size Total current Power Current Speed of rotation SMPA-040 4,5 A 1,6 kw,8 A 2800 rpm SMPA-050 12,0 A 6,2 kw 11,6 A 2910 rpm SMPA-06 16,0 A 8, kw 15,6 A 2910 rpm Control unit SMPZ-2 junction box frequency converter automatic control system Wiring diagram and electric connections X1 FREQUECY COVERTER Supply cable max 5x6mm T-S, L + Ue 400 Vac, 50 Hz x2,5+2,5 screen MAX. LEGTH 15 m 2x1,5 Q1 2 4 6 1 5 SAFE 1 01 2 4 6 1 5 21 22 L1 L2 L L1 L2 L U V W 1 2 PRESSURISATIO FA TF01 LIEAR MOTORS STO1/02 PRESSURE RU SIGAL TRASMITTER dpt 01 STAIRWELL SMOKE DETECTORS L 1x20 Vac, 50 Hz SUPPLY SD APARTMET SMOKE DETECTOR M WIDOW OIG MOTOR MAUAL WIDOW OIG "FAULT SIGAL L 1x20 Vac, 50 Hz SUPPLY SD APARTMET SMOKE DETECTOR M WIDOW OIG MOTOR MAUAL WIDOW OIG "FAULT SIGAL CABLIG BETWEE MOTORS AD SAFETY SWITCHES ICLUDED I FLÄKT WOODS SUPPLY OTHER CABLIG TO BE ISTALLED BY A ELECTRICIA AT SITE CABLIG SHALL BE FIRE RESISTAT OR OTHERWISE PROTECTED AGAIST FIRE Fläkt Woods FILO E 2009.07 7 All rights reserved.

Electric and control equipment Control panel SMPZ- for controlling pressurisation with indicator lights PRESSURISATIO STADBY SERVICE PRESSURIS. FA O PRESSURISATIO STADBY SERVICE PRESSURIS. FA O MA MA Differential pressure transmitter SMIZ-4 for controlling the fan to be installed in the stairwell Smoke detector FDRC-2-SMIA (Optional extra) Fläkt Woods FILO E 2009.07 8 All rights reserved.

Apartment air release path General For proper operation of the pressurisation system, there must be an automatically opening air release path in the smoke detector is activated, allowing gases to escape outside. The air release path shall be located near the apartment entrance to prevent interior doors, etc. from restricting the gas flow. The air release path can be a window, a smoke extraction damper, or other appropriate solution. A key design principle to consider is that the minimum free area of the air release path shall be 0.5 m2, in order to reach an air flow of at least 0.75 m/s through an open door. Air release paths to be incorporated into the facade shall always be designed in close cooperation with the architect and fire authorities, which means that the need for smoke extract solutions in apartments is an issue that should be addressed already at the initial meeting of a new project. The SMOKE MASTER SMPA control unit needs a signal from the apartment system via a potential free, normally open contact. Complete smoke extraction window solutions (with spindle motors, control units, and smoke detectors) facilitate the design and implementation process. The following companies supply smoke extraction window solutions that are compatible with the Fläkt Woods SMOKE MASTER SMPA system: Pressurisation without apartment air release path For the pressurisation system to comply with the relevant standards, there should be a air release path in each apartment. In reality, however, it may not always be possible, for some reason or another, to use apartment smoke extraction windows. If a decision is made, in consultation with rescue authorities and building control officers, to deviate from the standards and use the SMOKE MASTER SMIA pressurisation system without air release paths in the apartments, the following should be observed: To minimise the risk of having a door open to a burning apartment, door closers or similar equipment should be used to ensure that the doors close in the event of a fire. Moreover, through guidance and fire drills the occupants can be advised to close the apartment doors in case of fire. If the smoke detectors are placed in the stairwell, there should be detectors at each landing. Fläkt Woods supplies smoke detectors (FDRC-2-SMPA) that allow direct connection to the control unit. MOVETEC Oy, ESPOO, FILAD Tel. +58 400 41254, +58 9 525920 www.movetec.fi ROCA Finland Oy, TURKU, FILAD Tel. +58 20 74897 www.roca.fi Fläkt Woods FILO E 2009.07 9 All rights reserved.

Installation These instructions are also supplied with every SMPA system. For more information, please contact your local Fläkt Woods dealer. 1. Wall mounting Threaded bar M10 Installation opening (b+50) x (h+50) Size A B b H h L 040 689 86 721 707 571 70 050 802 952 87 820 686 778 06 92 1080 965 947 81 778 Fläkt Woods FILO E 2009.07 10 All rights reserved.

Installation and Product code 2. Roof mounting Installation opening (b+50) x (h+50) Support brackets, e.g. L60x60x5 Product code Pressurisation and smoke exhaust system Size (cm) 040, 050, 06 SMPA-aaa Optional extras: Smoke detector FDRC-2-SMIA The basic package includes: Fan unit Control unit Control panel Differential pressure transmitter SMPA-1 SMPZ-2 SMPZ- SMIZ-4 Component codes (when ordering individual components): Fan unit Size (cm) 040, 050, 06 Control unit Size (cm) 040, 050, 06 Control panel Differential pressure transmitter SMPA-1-aaa SMPZ-2-aaa SMPZ- SMIZ-4 Fläkt Woods FILO E 2009.07 11 All rights reserved.

We Bring Air to Life Fläkt Woods is a global leader in air management. We specialise in the design and manufacture of a wide rande of air climate and air movement solutions. And our collective experience is unrivalled. Our constant aim is to provide systems that precisely deliver required functions and performance, as well as maximise energy efficiency. Solutions for all your air climate and air movement needs Fläkt Woods is providing solutions for ventilation and air climate for buildings as well as fan solutions for industry and infrastructure. Air Handling Units (AHUs) Modular, compact and small AHU units. Designed to ensure optimisation of indoor air quality, operational performance and service life. Air Terminal Devices and Ducts Supply and exhaust diffusers and valves for installation on walls, ceiling or floor are all included in our large range and fit all types of applications. Chilled Beams Active induction beams for ventilation, cooling and heating, and passive convection beams for cooling. For suspended or flush-mounted ceiling installation - and multi-service configuration. With unique Comfort Control and Flow Pattern Control features. Fans Advanced axial, centrifugal and boxed fans for general and specialist applications. Comprehensive range including high temperature and ATEX compliant options. Engineered for energy efficiency and minimised life cycle cost. Chillers Air-cooled and water-cooled chillers with cooling capacity up to 1800 kw. Designed to minimise annual energy consumption in all types of buildings. Controls and drives Variable speed drives and control systems, all tested to ensure total compatibility with our products. Specialist team can advise on energy saving and overall system integration. Residential ventilation A complete range of products for residential ventilation. Consists of ventilation units, exhaust air fans and cooker hoods designed to optimise indoor comfort and save energy. SMPA Technical data / E / 07.2009 / All rights reserved. Fläkt Woods Oy Kalevantie 9, FI-20520 Turku, FILAD Tel. +58 20 442 000 www.flaktwoods.com