Ultra-Safe EXP Unit Heater

Similar documents
ULTRA-SAFE EXP. Applications E X P L O S I O N - P R O O F H E A T E R S

ULTRA-SAFE Explosion-proof Duct Heaters

FX5 Series Explosion-Proof Electric Air Heaters

ULTRA-SAFE Explosion-proof Duct Heaters

Explosion-Proof and Fan-Forced Unit Heaters. Our products do more in a wide range of applications. Expect More.

FE1 Explosion-Proof Electric Air Heaters

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

Comfort. Description. Applications

Explosion-Proof Forced Air Unit Heater - XGB

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

Explosion-Proof Forced Air Unit Heater - XGB

Brasch Hazardous Location Unit Heaters

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

Description. Applications

Description. Construction

XEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

CR1 Series Triton Corrosion Resistant Washdown Heaters

KUH. Horizontal Unit Heater. Applications. Description

Thermal Devices, Inc. Mount Airy, Maryland USA

Description. Applications

Industrial Air Heaters

HLA Series Hazardous Location Fan Forced Unit Heater

HLA Series Hazardous Location Fan Forced Unit Heater

TABLE OF CONTENTS. FCV Nomenclature 3. FCV Features & Construction 4. FCV Engineering Specifications 5. FCV Fan/Coil Data 6

HUH2. Hydronic Unit Heater CRN: 0H C 400 psig (2758 KPa) Industrial Grade Heat-Exchanger Unit Heaters

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

MAC N-407 Air-Cooled Chiller

Tubular Industrial Process

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

CX1 ProVector Explosion-Proof Heaters

Explosion Resistant Unit Heater Owner s Manual This manual covers installation, maintenance, repair, and replacement parts.

MAC-120HE-03 Air-Cooled Chiller

CF1 ProVector Explosion-Proof Heaters

MACH N-407 Heat Pump Air-Cooled Chiller

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

LUH HORIZONTAL FAN-FORCED UNIT HEATER

CXH-A Forced-Air Heater

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

Type UB-2502A and UB-3002A Forced-Air Heater

Electric Unit Heaters for Standard and Hazardous (Classified) Locations

HLA Series Hazardous Location Fan Forced Unit Heater Data Sheet

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Product Specifications. Vertical Floor Consoles By First Co.

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

FX5 SD Series Electric Forced Air Heaters for Hazardous Locations

Tubular Industrial Process

Electric Unit Heaters

EXH Series Explosionproof Electric Air Heaters

SECTION (15767) - UNIT HEATERS

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Custom Duct Heaters. Special Applications

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Call us today! (800)

SECTION AIR COILS

Owner s Manual. FX4 Series. Electric Forced Air Heaters for Hazardous Locations

30GT FLOTRONIC AIR-COOLED CHILLERS

Circulation Heaters Selection Guidelines

1.1 This section applies to air handling units for HVAC Systems.

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).


Direct Gas-Fired Make-Up Air

Call us today! (800)

Call us today! (800)

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Immersion Heaters. Screw Plug Immersion Heater

PACKAGE AIR CONDITIONER

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

SECTION AIR DOORS

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

30GN FLOTRONIC II AIR-COOLED CHILLERS

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

TECHNICAL SPECIFICATIONS

SECTION ROTARY-SCREW WATER CHILLERS

X Series (Model B) Explosion Proof Heater

Explosion-proof Duct Heaters

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

Commercial Heating Products. Our products do more in a wide range of applications. Expect More.

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

HVAC. Air Blowers Fans Forced Air Heaters Heating Cables & Insulation Infrared & Radiant Heaters

Capacity: 1.5 to 6.0 Ton

Custom Duct Heaters. Special Applications

Why settle for anything less?

Construction Standards Page

PAJ3. Product Specifications

RGE 13 A T - 1 A

Product Chillers A P P L I C AT I O N S

PART NO. COMBUSTION AIR CAP

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

Transcription:

INDEEO s ULTRA-SAFE EXP explosion-proof unit heater is designed with both safety and versatility in mind. Unique ULTRA-SAFE EXP features include: Industry s Lowest Ignition Temperature ode Rating: T3, 320 F (160 ) Dual Overtemperature Protection: With both automatic and manual reset overtemperature cutouts for additional safety. Nontoxic Propylene Glycol Heat Transfer Fluid Applications Aircraft Hangars/Service Areas hemical Storage/Handling Areas oal Preparation Plants ompressor Stations Grain Elevators Oil Refineries and Rigs Paint Storage Areas Petrochemical Plants Sewage Pump Stations/ Treatment Plants Spray Booths lass I, Divisions 1 and 2, Groups and D lass II, Divisions 1 and 2, Groups E, F and G lass I, Zones 1 and 2, Group IIB Temperature ode T3, 320 F (160 ) Low 70 PSIG Relief Valve Setting: This assures that in an emergency, the initial escaping vapor temperature remains below the 320 F (160 ) ignition temperature. orrosion Resistant Options: INDEEO offers three constructions suitable for most applications. Standard construction for use in dry non-corrosive areas includes: welded steel heat exchanger; powder-coated cabinet. A 316 stainless steel construction suitable for Waste Water Treatment Plants includes: 316 stainless steel heat exchanger, headers and tubes with aluminum fins; stainless steel cabinet; corrosion resistant hardware. Third construction is suitable for use in hemical Plants where chlorides are present and includes: Heresite coated heat exchanger, cabinet, fan blade; corrosion resistant hardware. Standard onstruction Features Heat Exchanger Efficient liquid-to-air design utilizes an all welded steel headers and finned tube construction with spiral wound aluminum fins. Industrial grade INDEEO heating elements are immersed in a nontoxic, inhibited, propylene glycol heat transfer fluid that provides freeze protection down to -49 F (-45 ). The heat exchanger is hydrostatically tested at 350 psig. A pressure relief valve provides excess pressure protection and is set at 70 psig. Fan Motor Assembly onsists of an explosion-proof motor fitted with an aluminum fan blade. The motor has doubleshielded, permanently lubricated ball bearings and automatic reset line breaking thermal overload protection. Motors furnished on standard units operate at line voltage and are prewired to the control enclosure so separate field wiring to the motor is not required. The standard motor is rated for lass I, Groups and D, lass II, Groups F and G. The minimum operating temperature is -14 F (-25 ) and the minimum storage temperature is -49 F (-45 ). Optional motor ratings are described on page 9. abinet/louvers Industrial grade, corrosion resistant construction fabricated from beige powder coated 14-gauge galvanized steel. The adjustable louvers have minimum opening safety stops. ontrols Factory mounted on the unit heater. Standard builtin controls include automatic and manual reset overtemperature cutouts, controlling magnetic contactor, and 24-volt control circuit transformer housed in a NEMA 7, 9 cast aluminum enclosure. 8

Factory Built-in Options ode Option Description ode (2) 1 316 Stainless Steel orrosion-resistant onstruction (Waste Water Treatment Plants) 316 Stainless steel heat exchanger with aluminum fins, 316 stainless steel cabinet; aluminum fan blade; cast aluminum NEMA 7, 9 control enclosure; corrosion-resistant hardware; corrosion-resistant protective coated motor, which has passed the TM B117 salt-spray test. 2 Dirty Duty orrosion-resistant onstruction (hemical Plants) Heresite coated heat exchanger, cabinet and fan blade; cast aluminum NEMA 7, 9 control enclosure; corrosion-resistant hardware; corrosion-resistant protective coated motor which has passed the TM B117 salt-spray test. D Disconnect Switch Factory installed on the unit heater above the control enclosure. This is an inexpensive and positive way to meet NE/E requirements for a disconnecting means within sight of the heater. E Group E (Metal Dust) onstruction lass II, Group E (Metal Dust) onstruction Temperature ode T3, 320 F (160 ) K Warning Pilot Light Indicates when the thermal cutouts have tripped and the unit heater needs servicing. L Heater On Pilot Light Indicates when the electric heating elements are energized. M Manual Reset Thermal utout with Backup ontactor A pilot duty manual reset thermal cutout with a backup contactor is provided for independent secondary overtemperature protection. This option cannot be provided if option ode S or V are also specified. S Auto/Fan Selector Switch A two-position switch wired to the control circuit for auto (automatic heat) and fan only control. This selector switch cannot be provided if option ode M or V are also specified. T Adjustable Thermostat Factory installed and prewired to the control enclosure. Thermostat is adjustable from 50 to 90 F (10 to 32 ) range. V 120 Volt ontrol ircuit an be provided when required for special external thermostat circuit. This option cannot be provided if option ode S or M are also specified. Nor can both K and L be specified. (2) = Assembly Stock, = ustom. Assembly Stock heaters ordered with custom options are subject to longer delivery. 9

Accessory Items ULTRA-SAFE EXP Heater Mounting Kits These are available for ceiling, wall and pole mounting configurations as described below. Specify type required and catalog number at time of order entry. 5" (127 mm) ULTRA-SAFEXP Explosion -proofunitheater 6-1/8" (159.76 mm) MW MH 2.5 (63.5) 5" (127 mm) ULTRA-SAFE EXP Explosion-proof Unit Heater ULTRA-SAFEXP Explosion -proofunitheater eiling Mounting Kit Wall Mounting Kit MW Pole Mounting Kit Size MH In. (mm) MW In. (mm) 1 11.063 (281) 9 (228.6) 2 15.063 (382.6) 7 (177.8) 3 19.063 (484.2) 5 (127) Unit Heater Mounting Kits (One kit required per heater) Standard Mounting Kits for use in most applications Description 1022451 eiling Mounting Kit, for Frame Size 1, 2, 3 1022454 Wall Mounting Kit, for Frame Size 1, 2, 3 1022457 Pole Mounting Kit, for Frame Size 1, 2, 3 ode (2) 10 Optional Mounting Kits for Option 1 or 2 heaters Description 1022451-S orrosion Resistant eiling Mounting Kit, for Frame Size 1, 2, 3 1022454-S orrosion Resistant Wall Mounting Kit, for Frame Size 1, 2, 3 1022457-S orrosion Resistant Pole Mounting Kit, for Frame Size 1, 2, 3 (2) = Assembly Stock, = ustom. Assembly Stock heaters ordered with custom options are subject to longer delivery. Accessory Remote Thermostat 1007002 Bimetal 1024754 1025396 Switch Type Description Type Ratings Bulb and apillary with Internal Set Point Adjustment Bulb and apillary with Internal Set Point Adjustment lass 1, Div. 1, Groups & D lass II, Div. 1, Groups E, F, & G lass 1, Div. 1, Groups B, & D lass II, Div. 1, Groups E, F, & G orrosion-resistant lass 1, Div. 1, Groups B,, & D lass II, Div. 1, Groups E, F & G SPDT SPDT SPST 125-277V, 22A 120-240V, 25A 277V, 22A 120-240V, 25A 277V, 22A ode (2) Temp. Range 0F (0) 500-900 (100-320) 400-1200 400-1200 ode

Dimensions, Airflows and Weights Overall Heater Dimensions Weight 60 Hertz Heaters Airflow haracteristics Motor/Fan 50 Hertz Heaters Airflow haracteristics Motor/Fan Frame Size Size 1 Size 2 Size 3 X In. (mm) 21.75 (552.45) 21.75 (552.45) 20.875 (530.23) Y In. (mm) 19.375 (492.125) 23.375 (593.725) 27.375 (695.325) Z In. (mm) 16.063 (408) 20.188 (512.775) 24.188 (614.375) Net Lbs. (kgs) 110 (49.89) 150 (68.03) 190 (86.18) Shipping Lbs (kgs) 130 (58.96) 169 (76.65) 216 (97.97) KW Range 3-5 7.5-10 15 20 25 30 Air Volume FM (cubic meter/hr.) 650 (1104) 850 (1444) 1800 (3058) 3110 (5283) 3850 (6541) Air Throw Feet (m) 15 (4.5) 25 (7.6) 45 (13.7) 65 (19.8) 75 (22.8) RPM 1725 HP 1/4 1/2 Fan Blade Dia. In. (mm) 12 (304.8) 16 (406.4) 20 (508) KW Range 2.5-4.2 6.3-8.4 12.5 16.7 21-25 Air Volume FM (cubic meter/hr.) 550 (934) 700 (1189) 1500 (2549) 2600 (4417) Air Throw Feet (m) 13 (4) 22 (7) 39 (12) 57 (17) RPM 1438 HP 1/4 1/2 Fan Blade Dia. In. (mm) 12 (304.8) 16 (406.4) 20 (508) Y X Side View 6-3/4 Z Front View 11

ULTRA-SAFE EXP Unit Heater Listing 60 Hz lass I, Divisions 1 and 2, Groups and D lass II, Divisions 1 and 2, Groups F and G lass I, Zones 1 and 2, Group IIB Temperature ode T3, 320 F (160 ) KW Volts Phase 3 5 7.5 10 15 20 25 30 Total Amps (1) Frame Size Approximate Air Temperature Rise F ( ) 208 1 17 1 15 (8) 233-FA-0036 240 1 15 1 15 (8) 233-FA-0036J 208 3 10 1 15 (8) 233-FA-0036D 240 3 9 1 15 (8) 233-FA-0036K 480 3 5 1 15 (8) 233-FA-0036U 600 3 4 1 15 (8) 233-FA-0036Z 208 1 26 1 25 (13) 233-FA-0056 240 1 23 1 25 (13) 233-FA-0056J 208 3 16 1 25 (13) 233-FA-0056D 240 3 14 1 25 (13) 233-FA-0056K 480 3 7 1 25 (13) 233-FA-0056U 600 3 6 1 25 (13) 233-FA-0056Z 208 1 38 1 28 (16) 233-FA-0086 240 1 34 1 28 (16) 233-FA-0086J 208 3 23 1 28 (16) 233-FA-0086D 240 3 20 1 28 (16) 233-FA-0086K 480 3 10 1 28 (16) 233-FA-0086U 600 3 9 1 28 (16) 233-FA-0086Z 240 1 44 1 38 (21) 233-FA-0106J 208 3 30 1 38 (21) 233-FA-0106D 240 3 26 1 38 (21) 233-FA-0106K 480 3 13 1 38 (21) 233-FA-0106U 600 3 11 1 38 (21) 233-FA-0106Z 208 3 44 2 27 (15) 233-FB-0156D 240 3 38 2 27 (15) 233-FB-0156K 480 3 19 2 27 (15) 233-FB-0156U 600 3 16 2 27 (15) 233-FB-0156Z 480 3 25 2 35 (19) 233-FB-0206U 600 3 21 2 35 (19) 233-FB-0206Z 480 3 31 3 26 (14) 233-F-0256U 600 3 25 3 26 (14) 233-F-0256Z 480 3 37 3 25 (13) 233-F-0306U 600 3 30 3 25 (13) 233-F-0306Z (1) Total Amps = Heating element amps and motor amps. (2) = Assembly Stock, = ustom. Assembly Stock heaters ordered with custom options are subject to longer delivery. (2) 12

ULTRA-SAFE EXP Unit Heater Listing 50 Hz lass I, Divisions 1 and 2, Groups and D lass II, Divisions 1 and 2, Groups F and G lass I, Zones 1 and 2, Group IIB Temperature ode T3, 320 F (160 ) KW Volts Phase 2.5 4.2 6.3 8.4 12.5 16.7 21 25 Total Amps (1) Frame Size Approximate Air Temperature Rise F ( ) 220 1 14 1 14 (8) 233-FA-0036E 220 3 9 1 14 (8) 233-FA-0036F 380 3 6 1 14 (8) 233-FA-0036G 400 3 6 1 14 (8) 233-FA-0036H 415 3 5 1 14 (8) 233-FA-0036I 220 1 21 1 24 (13) 233-FA-0056E 220 3 13 1 24 (13) 233-FA-0056F 380 3 9 1 24 (13) 233-FA-0056G 400 3 8 1 24 (13) 233-FA-0056H 415 3 7 1 24 (13) 233-FA-0056I 220 1 31 1 28 (16) 233-FA-0076E 220 3 19 1 28 (16) 233-FA-0076F 380 3 12 1 28 (16) 233-FA-0076G 400 3 11 1 28 (16) 233-FA-0076H 415 3 10 1 28 (16) 233-FA-0076I 220 1 40 1 38 (21) 233-FA-0096E 220 3 24 1 38 (21) 233-FA-0096F 380 3 15 1 38 (21) 233-FA-0096G 400 3 13 1 38 (21) 233-FA-0096H 415 3 13 1 38 (21) 233-FA-0096I 220 3 35 2 26 (14) 233-FB-0136F 380 3 21 2 26 (14) 233-FB-0136G 400 3 19 2 26 (14) 233-FB-0136H 415 3 18 2 26 (14) 233-FB-0136I 220 3 46 2 35 (19) 233-FB-0176F 380 3 28 2 35 (19) 233-FB-0176G 400 3 25 2 35 (19) 233-FB-0176H 415 3 24 2 35 (19) 233-FB-0176I 380 3 33 3 26 (14) 233-F-0216G 400 3 32 3 26 (14) 233-F-0216H 415 3 31 3 26 (14) 233-F-0216I 380 3 39 3 30 (17) 233-F-0256G 400 3 37 3 30 (17) 233-F-0256H 415 3 36 3 30 (17) 233-F-0256I (1) Total Amps = Heating element amps and motor amps. (2) = Assembly Stock, = ustom. Assembly Stock heaters ordered with custom options are subject to longer delivery. (2) 13