Weninger GmbH & Co KG Hag 7 A-6410 Telfs

Similar documents
EN INSTRUCTIONS

Watering systems for your plants

sensor into the soil about 6 to 7 inches deep (15-18 cm).

Thanks for shopping with Improvements! Solar Rainmaker Automatic Plant Watering System Item #

Clever Irrigation. Micro-Drip-System

GARDENA Watering Systems 2012

Moisture inside the drum is due to final testing.

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

GARDENA Watering Systems 2011

OWNER S MANUAL. Solar Collector DELUXE

Installation Guide. Maximum Area 20m 2

Operation Manual. Mobile Dustfree Pressure Air Blasting System HSP-20

More enjoyment when watering. Irrigation

CONDITIONS OF SALE AND WARRANTY

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

ULTIMATE REVERSE OSMOSIS SYSTEM

HAND-OPERATED GREASE PUMPS 181

Moisture inside the drum is due to final testing.

Pixel Pot Vertical Planting Kit

Do not touch hot parts (chimney pipe, firebox and hatch). Carefully read through the manual for the heater.

OTO BONDER OWNER S MANUAL WITH CIRCULATING SYSTEM MACHINERY DIVISION - - L to R Unit Shown

Product overview Suction Guns, suction machines, Vac-Blast Cleaners

Operating Manual. Reverse Osmosis Water Purifier. MELAdem 55

OWNERS GUIDE TO INSTALLATION AND OPERATION

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

MULTI FLOW HYDROPONIC SYSTEM

Electric Decoral (Thermalist) Radiators

GETZ MANUFACTURING PART NO.: MODEL: SV1 100 PR VACUFILL SYSTEM (Revised 6/7/05)

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

Simply perfect garden watering. With these step-by-step instructions, you can quickly and easily plan your customised Kärcher Rain System.

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

MODULAR AUTOMATIC GRANULAR ICE FLAKER

Instructions for Installation, Operation, Care and Maintenance

Fig. 1. Bottle Height---Top of bottle MUST be at this height or slightly higher.

Parasitic Cysts - Cryptosporidium and Giardia, Chemicals, Heavy Metals, Dissolved Salts, Offensive Tastes and Odours, Sediment, Dirt,

AUTOMATIC MODULAR ICE FLAKER

Oblo Basin and Bidet Monobloc Installation and User Guide

OPERATOR'S MANUAL CD 400 / CD 500

20-GALLON PARTS WASHER OWNER S MANUAL

Drying Cabinet Installation and Operating Manual

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

Mechanical seals external, single or double, to DIN EN 12756

Venco 75mm (3 ) Standard and De-airing Pugmill

RTP9 ROTARY TABLET PRESS USER MANUAL

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

GETZ EQUIPMENT INNOVATORS PART NO.: 9G58619 MODEL: SV1 150 PR VACUFILL SYSTEM (Revised 2/25/14)

User Manual for MullToa 10 and 25

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

General System Layout Sketch

100 Series Maxi Internal Filters

Sustainable Village, LLC 1080 Oakdale Place, Boulder, CO 80304

MJC Cartridge Filter Unit Operation & Maintenance

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

INTRODUCTION SPECIFICATIONS. Pump Flow Curve

Geothermal Energy Nutrient Reservoir & Trench cooling System

2001 Smith Eastern Corporation

GREEN LOO DRY COMPOSTING TOILET Owners Installation Operation Manual. for the. GT 120 Family and GT 330

BioMaster 250/350/600 BioMaster Thermo 250/350/600

CONDITIONS OF SALE AND WARRANTY

Simply drop into your water butt and use a hose and spray gun as easily as using the tap. Much easier than using a watering can!

Singulier Spout Tube Basin Mixer Installation and User Guide

TABLE OF CONTENTS FOR YOUR SAFETY

INSTALLATION GUIDE. soft duomatik evoline

Operating and Maintenance Instructions

PolyMax H2-24 Dutch Bucket System

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

AUTOMATIC GRANULAR ICE FLAKER

BACK WASH INSIDE THE SPA

DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

EFX 600. aquamanta. Instruction Manual. 4year guarantee. the experts in aquatic technology. >600 Litres

TANKLESS REVERSE OSMOSIS SYSTEMS USER S MANUAL

Installation and Operating Instructions

Drip Irrigation Kit Installation Manual

Owner s manual for. Venco 87mm & 100mm. (3 1/ 2 & 4 ) De-airing Pugmill

DESIGN & SIZING GUIDE

SERVICE MANUAL DISHWASHERS DIVA ACCESSIBILITY DISHWASHERS

AUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM

SFD. Suburban Filter Dryer. User Manual Installation Instructions

Instructions for use. 301 plus

Installer manual GreenMaster-HP

NEPTUN I Sole cleaning unit Art.-No.:

READ CAREFULLY AND KEEP FOR FUTURE REFERENCE

Bottle Height Adjustment Bottle Diameter Adjustment Cork Length Adjustment Cork Depth Adjustment

Installation instructions Air drying unit for Bubble Sensor OTT CBS. English

SELF-PRIMING JET PUMPS

ElEctronIc 2 DIal tap timer co1701 InstructIon Manual

English Manual for Jewelry Casting and Investing The professional choice

M07. Wunda Premium Manifold. Before you start: Check the contents THE BRAND YOU CAN TRUST

Oil burners fuel unit with solenoid valve

5900S Softener Installation & Start-Up Guide

General System Layout Sketch

SOLARMATIC TM. Solar Pool Heating Controller OWNERS MANUAL. Manufactured in Australia By

Oil burners fuel unit with solenoid valve

AUTOMATIC ICE-CUBE MAKER

INSTALLATION INSTRUCTION Ver

DELUXE OPERATIONAL MANUAL

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

Transcription:

A further innovation from our assortment Fully-automatic watering system for INDOOR PLANTS.» The extremely simple Blumat system is the best method for indoor plants that require little water.» The water is delivered directly through the ceramic cone. The water is drawn from any optional container via the thin hose.» Blumat is ready to use at any time.» The plants remain in their normal location.» No re-potting required.» Blumat is the ideal watering system when on vacation.» Can also be used the whole year round. by werbeagentur innsbruck-telfs 0664/308 44 35 Weninger GmbH & Co KG Hag 7 A-6410 Telfs within Austria outside Austria BLUMAT-CONSULTATION-SERVICE: I F YOU HAVE ANY QUERIES OR REQUESTS WITH REGARD TO SPECIAL APPLICATIONS, CALL... Tel. 0 52 62 / 62 4 35 Fax 0 52 62 / 62 4 35-7 Tel. 00 43 / 52 62 / 62 4 35 Fax 00 43 / 52 62 / 62 4 35-7 e-mail: info@blumat.at internet: www.blumat.info

Content» Easy and trouble-free to install 3 6» Water tap or elevated tank as source 6» Tropf-Blumat function 7» How many Tropf-Blumats do your plants require 8» What if...? 9» Blumat-Sets and supplementary packages 10» Using Tropf-Blumat accessories 11 Congratulations on purchasing Tropf-Blumat Flowers on balconies and terraces are on the one hand the adornment of every house, but on the other hand also demand constant care and attention. Even vegetable plants in greenhouses are only so-to-speak crispy fresh with regular watering. With Tropf-Blumat you have decided on a watering-system, that assists you in two ways. Since now you will not only be spared the watering, but also, above all, unnecessary water consumption. The plants draw namely only the quantity that they really need. Since neither a power connection nor control is required for this system, it is also childsplay to install. The only tool you require is a pair of scissors. For the precise method of assembly, please refer to our clear and well illustrated assembly guide. With Tropf-Blumat, you and your plants are guaranteed to have absolute joy. Roland Weninger WENINGER GMBH & CO KG Easy and trouble-free to install» STEP 1 Unscrew green watering head- and ceramic sensor. Fill to the brim with water. TIP: Fill under water and screw together at the same time.» STEP 2 Then screw together tightly again up to the stop ring. Sensor must be sealed air-tight. 3 Stop ring» STEP 3 Immerse the Tropf-Blumat, filled with water and tightly screwed, in water for at least 1 hour, so that the ceramic ball can completely absorb the water. 1 2 3

4 5 Easy and trouble-free to install Easy and trouble-free to install» STEP 4» STEP 5» STEP 6» STEP 7 In the meantime, establish the hose connection to the pressure reducer or elevated tank. If you immerse the feeder hose in hot water for 5 min. or leave in the sun, it will be easier to lay. drill hole ø 12 mm Elevated tank connection IMPORTANT: Please water the ground generously several times before using the Tropf-Blumat. Insert the Tropf-Blumat in the ground near the roots to the depth marked at intervals of Insert depth 4 5 approx. 20 to 25 cm. Ensure good contact with the ground (PIC 5). At the end of the system, fit the Tropf-Blumat with the end piece. (if necessary remove T-piece and replace with end piece [PIC 6A]) 6 6A End piece Lay the feeder hose Cut off appropriately long hose-lengths from the feeder hose and connect the individual Tropf-Blumat units with them. Push the hose-lengths onto the Tropf-Blumat T-connection pieces properly and firmly. Ensure correct hose seating. This is made simple and easy by moistening the T-piece. Do not use any lubricant (grease, soap, etc.) when fitting! Turn on the tap. IMPORTANT: Before setting, all Tropf-Blumat units must be closed. Simply turn the brown setting screw in a clockwise direction. No dripping may occur anywhere. 7 7A Open by turning the setting screw in an anticklockwise direction. Now water drips from the dripper hose, which must protrude approx. 8 cm from the Tropf-Blumat (SEE PIC 7). Then slowly turn the setting screw in a clockwise direction again, so that just a drop of water clings to the dripper hose. Then close the setting screw further by 2 marking arrows in a clockwise direction (PIC 7A). The Tropf-Blumat should not discharge any water when the ground is wet.

Easy and trouble-free to install» STEP 8 Altering the ground moisture After the installation you should check the water delivery for about 1 2 weeks at 2-day intervals and adjust if necessary by opening (= more water) or closing (= less water). In most cases a rotation of 1 /2 marking arrow is sufficient. (SEE YELLOW CROSS-HATCHED AREA) An optimally set water delivery does not need to be altered. Water tap or elevated tank as source 1 2 6 7 TIP: Fit a 2-way distributor on the water tap and you have a second outlet. 1 We recommend that the connection on the water tap is fitted with a pressure reducer. If the water tap is located in the garden, then balconyand hanging flowers at a height of max. 4 m can also be supplied. Consequently, refilling the elevated tank is then unnecessary. 2 If only one elevated tank is in question, this must stand at least 0.5 m higher than the Tropf-Blumat system for each 5 m hose length. For 10 m hose therefore, at least 1 m. Tropf-Blumat function» The fully-automatic plant-watering system Tropf-Blumat operates fully automatic. If the ground is dry, then its suction pressure triggers the watering operation. The integrated membrane in the Tropf-Blumat opens and releases the flow of water. When the ground has been Ground dry sufficiently moistened, the water delivery ceases independently. Each Tropf-Blumat sensor reacts completely independently. It takes into account the solar radiation, air temperature, humidity and plant growth. Ground wet Maintenance and winter storage When dismantling the system, clean the ceramic sensor inside and out with water and store protected from frost. Incrustations on the ceramic cone can be removed with sand paper. All hoses can remain in the open air. Fertilisation We recommendlong-term fertilisers, that are best added to the ground during planting. Naturally, you can however also give the plants the nutrients with a watering can. Guarantee We provide a 24 month guarantee for all Blumat products from the date of purchase. Should you have cause for complaint, send us the defective component together with the purchase receipt.

A B C D How many Tropf-Blumat units do your plants need? One Tropf-Blumat unit waters on average approx. 20 25 cm of ground. YOU NEED: e. g. for watering balcony boxes of: 100 cm length: at least 4 Tropf-Blumat units 80 cm length: at least 3 Tropf-Blumat units 60 cm length: at least 2 Tropf-Blumat units e. g. for watering plant pots: up to 25 cm ø: 1 Tropf-Blumat unit (SEE SKETCH B1) of 25 to 40 cm ø: 2 Tropf-Blumat units (SEE SKETCH B2) of 40 to 50 cm ø: 3 Tropf-Blumat units (SEE SKETCH B3) For larger containers or in beds, distribution drippers can also be used instead of additional Tropf-Blumat units. Each single Tropf-Blumat unit and 5 distribution drippers can water e.g. an area of 40 cm width and 50 cm length. With the 8 mm ø feeder hose, you can operate a flower arrangement of 60 running metres, that is 250 drippers. If your arrangement is larger, fit the enclosed hose branch in series directly after the pressure reducer. This way you can connect 2 x 60 m flower arrangements or 500 drippers. 8 9 A B EXAMPLE SKETCH D C 1x 60 Running metre 2x 60 Running metre What if» IMPORTANT NOTES: Always leave the water tap turned on or replenish the water tank in good time. Even when it is raining. With longer interruptions to the water supply, the roots can suck the water out of the sensor. Don t be fooled by a dry ground surface. The water spreads underground like an onion. Often only the ground surface under the dripper hose is visibly moist.» TIPS when going on vacation Install the system at least 10 days before. Support the plants from falling down and do not place in subsoil susceptible to damp. Eventual water leaks must also not cause any other damage (e. g. flow into cellars or the like) The sensor runs out of water? POSSIBLE SOURCES OF THE Air has entered the system, poorly screwed together, buckled dripper hose, poor ground contact, interrupted water supply. Refill the ceramic sensor with water and screw together tightly up to the marking ring. The watering diameter is too small? POSSIBLE SOURCE OF THE Dripper hose is too short. The water therefore reaches the ceramic sensor too quickly. Extend dripper hose to 8 cm. Tropf-Blumat does not turn off? POSSIBLE SOURCE OF THE Membrane has too little tension (can occur after cold nights). Close the setting screw approx. 1 /2 mark. No water comes out of the dripper hose? POSSIBLE SOURCE OF THE Hose is blocked, stuck or supply buckled. Withdraw the dripper hose a little and knead the compressed part between the fingers. The Tropf-Blumat watering system has been specially developed for outdoor plants. Therefore please do not use indoors.

10 11 Blumat-Sets and supplementary packages Using Tropf-Blumat accessories With the Blumat-Sets and supplementary packages, you can install and expand your watering system individually. Pressure reducer ready to connect for water tap Tropf-Blumat Supplementary package Feeder hose white / black 10-m-roll, Shut-off valve for feeder hose Supports for feeder hose and distribution drippers Tropf-Blumat MAXI for big plants insertion depth between 15 and 18 mm» CONNECTING THE DISTRIBUTION DRIPPER Cut off pieces of hose approx. 20 cm from the thin dripper hose. Then connect max. 5 distribution drippers together. At the end of the chain, fit the distribution dripper to just one connection neck or seal the second outlet with the black stopper. Then connect the chain to the dripper hose end of the Method of using distribution drippers: Only with similar plants in the same pot or bed row! T-piece (union) Tropf-Blumat Distribution dripper End distribution dripper Dripper hose approx. 8 cm Dripper hose 20 cm Tropf-Blumat unit. It is important that the distance from the Tropf-Blumat sensor to the nearest distribution dripper is approx. 8 cm. (SEE SKETCH A) Lay the chain with the distribution drippers according to preference, near the plant roots. (SEE SKETCH B) In general, the black screw on the distribution dripper does not need to be adjusted, unless a distribution dripper obviously delivers too little water. In this case, open the black screw by one turn. If necessary, unscrew completely and clean (threads possibly soiled). Mini-branch + dripper hose for extending and branching Hose union for connecting feeder hoses Hose branch and end-piece for branching feeder hoses Elbow for changing the direction of the feeder hoses Distribution dripper + end distributiondripper for watering longer bed rows Flexible hose security clamp for all hoses including 8 mm T coupler SKETCH A SKETCH B Distribution dripper Support