Zurn Pex, Inc. Residential Fire Protection Presentation. PEX Plumbing, Radiant Heating and Residential Fire Protection Systems

Similar documents
Review of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings

2009 International Residential Code Draft of New Fire Sprinkler Related Requirements

What You Need to Know about Residential Sprinkler Design

What Builders Need to Know about Residential Sprinkler Design

RESIDENTIAL SPRINKLER INSTALLATION GUIDE

RESIDENTIAL SPRINKLER INSTALLATION GUIDE

RESIDENTIAL MULTI-USE FIRE SPRINKLER SYSTEMS PERMIT SUBMITTAL REQUIREMENTS

MONTECITO FIRE PROTECTION DISTRICT

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

freedom residential flush pendent sprinkler vk476 (K4.9)

Water Purveyor s Guide to 2006 Fire Sprinklers in Single Family Dwellings

Additional Bulletins applicable to all F1RES LL Sprinklers Wall Wetting - Bulletin 007 Design and Installation - Bulletin 140

RESIDENTIAL FIRE SPRINKLER SYSTEMS POLICY

Fire Protection Coffee Break Training August 2016

standard/quick response extended coverage light and ordinary hazard elo sprinklers

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

State Board of Examiners of Plumbing, Heating & Fire Sprinkler Contractors. Residential Fire Sprinkler Inspections

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description

Model F1 Residential Sprinklers for Design Density of.10 gpm/ft 2

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

NZS 4517:2010. New Zealand Standard. Fire sprinkler systems for houses. Superseding NZS 4517:2002 NZS 4517:2010

New Construction Fire Inspection Process

Data Sheet 4.24 Issue F

Residential Lead Free Flat Concealed Sprinkler, Pendent, Model: RC-RES, K-Factor: 4.9, SIN: SS8461

Residential Sprinkler For Sloped Ceilings

Residential Fire Protection PWD Experience

2007/2008 INTERNATIONAL RESIDENTIAL PLUMBING/MECHANICAL CODE COMMITTEE

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

SENJU SPRINKLER CO., LTD.

SENJU SPRINKLER CO., LTD.

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

40.49 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2744 QUICK RESPONSE

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

mirage standard response concealed pendent sprinkler vk492 (K5.6)

ESCUTCHEON PLATE SEATING 3/4" NPT SURFACE. 1-1/2" (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

Page 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts.

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

microfast sr/qr extended coverage pendent sprinkler

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK457 (K4.9) TECHNICAL DATA

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor General Description

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

Exaggerated for Clarity. Residential Pendent, Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

ATTIC UPRIGHT SPECIFIC APPLICATION SPRINKLER VK696 TECHNICAL DATA

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

Commercial Flat Concealed Sprinkler, Pendent, Quick Response, Extended Coverage (Light Hazard) Model: RC-QR-EC, K-Factor: 5.

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

TECHNICAL DATA OBSOLETE

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

TECHNICAL DATA OBSOLETE

culus Listed: Category VNIV Refer to the Approval Chart on page 3. VK697 Attic Upright Sprinkler Specifications:

FIRE SUPPRESSION SPRINKLER SYSTEM

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

1 Exam Prep NFPA 14 Stand Pipe Systems Questions and Answers (Plumbing Contractors)

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

Residential Flat Concealed Sprinkler, Pendent, Model: CN-RES, K-Factor: 4.9, SIN: SS8421

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

Fire Sprinklers The Ultimate Fire Fighters Eric Skare

Fire District Dwelling Construction Requirements

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

Report: Summary of Building Codes Division Process, Residential Fire Sprinklers December 2008

Commercial Flat Concealed Sprinkler, Pendent, Quick Response, Standard Coverage, Model: RC-QR, K-Factor: 5.6, SIN: SS9561

TECHNICAL DATA. Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Chart.

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

DESIGN & CONSTRUCTION GUIDELINES

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK534 (K11.2)

RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description

FIGURE 1. Model RD107

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

Sprinkler Identification Number (SIN) TY4234. Page 1 of 8 APRIL 2012 TFP Technical Services

FREEDOM RESIDENTIAL CONCEALED PENDENT LEAD FREE SPRINKLER VK4570 (K4.9) TECHNICAL DATA

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

Revise the metric values throughout the standard to follow the soft conversions provided by the metric task group

freedom residential horizontal sidewall sprinkler Vk450 (k4.2)

standard response elo upright and pendent sprinklers (storage-density/area)

STANDARD/quick. Sprinkler 42o. August 8, 2011

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

E x t E N d e d Co v e r ag e S p r i n k l e r s. Office Buildings Hotels Hospitals Libraries. High-Piled Storage Big-Box Retailing

Series LFII Residential Flush Pendent Sprinklers 4.2 K-factor General Description

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

NFPA Edition Update

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

DISCONTINUED PRODUCT

Data Sheet 4.16 Issue D

Transcription:

Residential Fire Protection Presentation Zurn Pex, Inc PEX Plumbing, Radiant Heating and Residential Fire Protection Systems Matt Lawrence BDM-North Central Region 1

Presentation Outline I. IRC Mandate II. III. a. Problem b. Purpose Cost IRC P2904 I. Differences Between P2904 and NFPA 13D IV. NFPA 13D IV. Chapter 1 V. Chapter 2 VI. Chapter 3 VII. Chapter 4 VIII. Chapter 5 IX. Chapter 6 X. Chapter 7 XI. Chapter 8 V. Prescriptive Design Method VI. Questions and Answers 2

Residential Sprinkler Problem U.L. Burn Test to Flashover: Legacy Rooms =>29.25 Modern Rooms =>3:40 Larger Homes Open Floor Plans Increased Fuel Loads Void Spaces New Construction Materials Large Homes + Open Spaces + Inc. Fuel Loads + Void Places + Construction Materials 3 There is a fire problem with new residential construction, and this problem is driving the mandate.

IRC Model Code-Sprinkler Mandate 2009 IRC Ch 3 Building Planning R313.2 One and two family dwellings automatic fire systems: Effective January 1, 2011, an automatic residential fire sprinkler system shall be installed in one and two family dwellings. -Research into code adoption has shown that by the time a code is 4 years old, only 33% of jurisdictions actually adopt it. Within 7 years, about 75% adopt it. Within 10 years, almost all jurisdictions do. -California -www.nfsa.org 4 IRC sprinkler code adoption will not be immediate.

Residential Sprinkler Cost NFPA Cost Report published by Newport Partners (3 rd Party) www.nfsa.org Range => $0.38 to $3.36 ($/ft 2 ) Average=> $1.61 ($/ft 2 ) MultiPurpose Average => $1.04 ($/ft 2 ) 5

Residential Sprinkler Cost NAHB Cost In a public statement, the NAHB claims that the range of cost can be from $3.30 30 to $8.00 ($/ft 2 ) Possible Additional Cost $6,000 potential water meter up charge to 1 from 5/8 Will be fought, Water Purveyor should not be able to do that. Miscellaneous charges for larger service pipe, alarm circuit, etc. Increased water line may be required to accommodate the potential increase in water flow. 6 The average cost of a residential MP sprinkler system is 1.04 ($/ft2), but water meter up charges could add cost pending the local water purveyor.

Residential Sprinkler NFPA 13D / P2904 2009 IRC Ch 3 Building Planning R313.2.1 1 Design and installation. Automatic residential fire sprinkler system shall be designed and installed in accordance with Section P2904 or NFPA13D. 7

Residential Sprinkler - P2904 IRC Section P2904 In comparison to NFPA13D, Section P2904 is a simple document (14 Pages vs. 35 in NFPA13D) Introduced Prescriptive Sizing, which allows residential sprinkler systems to be sized without the need for calculations. Keeps ¾ nominal minimum tubing size to sprinkler from water source. Network Systems cannot be used Cannot use shutoff valves that would isolate one or more sprinklers. www.ircfiresprinkler.org P2904 is a simple document when compared to NFPA 13D, but the IRC states that a system must be designed and installed to either P2904 or NFPA 13D. 8

NFPA13D 2010 Chapter 1: Scope & Purpose NFPA 13D Purpose The purpose p of this standard shall be to provide a sprinkler system that aids in the detection and control of residential fires and thus provides improved protection against injury, life loss, and property damage Prevent Flash Over Provide a safe means of escape for occupants. It is only a benefit that a majority of the time the fire is extinguished by the sprinklers. Minimizes damage to structure. Firefighters 9 The purpose of a system designed to NFPA 13D is to extend the time the occupants have to escape safely.

NFPA13D 2010 Chapter 3: Definitions Multipurpose Piping System => A piping system intended to serve both domestic and fire protection needs. PEX IPS CPVC Copper or iron pipe Network System => A type of multipurpose system utilizing a common piping i system supplying domestic fixtures and fire sprinklers where each sprinkler is supplied by a minimum of three separate paths. Other Definitions Include: Supply Pressure, System Pressure, Dwelling, Townhouse, Control Valve, Water Flow Alarm, Automatic Sprinkler, Residential Sprinkler Know the terminology of the industry. 10

NFPA13D 2010 Chapter 4: General Requirements Compartment The design demand area. Lintel Hydrostatic Test Where a fire department connection is not provided, the system shall be hydrostatically tested for leakage at normal operating pressures. Fire Department t Connections are rare in residential sprinkler systems. 11 Know the requirements that a residential sprinkler system must have.

NFPA13D 2010 Chapter 5:System Components Only new sprinklers shall be installed in sprinkler systems. Nonmetallic pipe used in multipurpose piping systems not equipped with a fire department connection shall be designed to withstand a working pressure of not less than 130 PSI at 120 F. UL 1821 Thermoplastic Sprinkler Pipe and Fittings for Fire Sprinkler Service CPVC and PEX Fittings also must be listed to UL 1821 12 Zurn PEX tubing (White Only) and applicable fittings are listed to UL 1821 for sprinkler supply.

NFPA13D 2010 Chapter 6: Water Supply Chapter 6 discusses acceptable water supply methods MultiPurpose System A piping system serving both sprinkler and domestic needs shall be considered to be acceptable by this standard where the following conditions are met. All piping pp in the system supplying ppy sprinklers is listed and conforms to NFPA 13D. Piping that is supplying only a plumbing fixture does not have to be listed for the sprinkler system. If water treatment devices are installed, certain criteria must be met. 13 Piping must be listed to UL 1821 if supplying a sprinkler, piping i supplying a plumbing fixture only does not have to meet 1821 but still must be meet all local plumbing requirements.

NFPA13D 2010 Chapter 6: Water Supply MultiPurpose System Supply 14

NFPA13D 2010 Chapter 7:Installation Valves A separate shutoff valve shall be installed for the domestic water supply in installations other than those complying with Section 6.3. Section 6.3 discusses Multipurpose Systems If a sprinkler system fails to operate during a fire, the primary reason for the failure is that t the sprinkler system is turned off. Drain and Test Connections Multipurpose systems are tested daily with use of plumbing fixtures. Other Advantages of a MP System Include Lower cost (product & labor) than stand-alone systems Confirmation of working system when cold water is used No stagnant water no backflow preventer Plumbing and fire protection installed by same contractor 15 There are many advantages of a MP system versus a stand alone system.

NFPA13D 2010 Chapter 7:Installation Piping Support Sprinkler Piping shall be supported in a manner that prevents the movement of the piping upon sprinkler activation. PEX utilizes nailing flanges on the fitting to prevent upward thrust, where CPVC utilizes more hangers. Zurn PEX Sprinkler Fitting 16 PEX in sprinkler systems is supported differently than CPVC.

NFPA13D 2010 Chapter 7:Installation Sprinklers Listed Residential Sprinklers shall be used unless other type is permitted. Provide sufficient distance from heat sources Shall not be painted unless supplied by the manufacture Types of Sprinklers Flush Concealed Recessed Pendent Concealed Pendent Horizontal Sidewall 17 Know sprinkler terminology and installation practices.

NFPA13D 2010 Chapter 8:Design Sprinkler Coverage, Position and Obstructions Sprinklers shall be installed in accordance with their listing where the type of ceiling configuration is referenced in the listing. Horizontal or Sloped Ceiling Pendent sprinkler deflectors shall be located 1-4 away from the ceiling. Pendent and upright sprinklers that have been listed with specific positioning criteria shall be positioned in accordance with their listening unless otherwise permitted. Pendent Sprinklers shall be a minimum of 3 away from obstructions. Typical sprinkler spacing: 12 x 12, 14 x 14, 16 x 16, 18 x 18, 20 x 20 18 Always refer to data sheets to confirm sprinkler is within manufactures listing.

NFPA13D 2010 Chapter 8:Design Sprinkler Design The system shall provide at least the flow required to produce a minimum discharge density of 0.05 GPM/ft2. Under flat, smooth, horizontal ceilings: include all sprinklers within a compartment, up to a maximum of two sprinklers, that require the greatest hydraulic demand. The minimum operating pressure of any sprinkler shall be the higher of the minimum operating pressure specified by the listing or 7 PSI. Pipe Sizing The minimum i size of pipe other than steel pipe shall be ¾ unless smaller sizes are permitted by 8.4.3.3 (Network Systems) NFPA13D does not require most of the items that are required for Network Systems (Hydraulic calculations shown for each sprinkler, no dead ends, plans, etc.) 19 Become familiar with sprinkler system design criteria: The two most hydraulically demanding sprinklers must discharge a minimum of 0.05 GPM/ft2 at a minimum pressure of 7 PSI.

20 NFPA13D 2010 Chapter 8:Design

21 NFPA13D 2010 Chapter 8:Design

NFPA13D 2010 Chapter 8:Design System Configurations NFPA13D permits multipurpose system configurations to be one of the following: Looped Gridded (Zurn PEX Preferred) Straight Run A combination of the first three Network A gridded system is preferred due to its simplistic design and favorable hydraulic characteristics. 22

Residential Sprinkler NFPA13D 2010 23 Gridded System

Residential Sprinkler NFPA13D 2010 24 Looped System

Residential Sprinkler NFPA13D 2010 25 Network System

Prescriptive Design Method P t = P sup PL svs PL m PL d PL e -P sup Safety Factors are Built into the Prescriptive Method. Typically will increase nominal tubing diameter. Already includes valves and fittings. Friction loss due to pipe pp is obtained from charts in P2904. Measured in available length of pipe at the specific flow rates and pressure losses. Prescriptive Design method is a simplified way to calculate out a sprinkler system. 26

Questions Questions? 27