1 of 36 9/22/2014 9:37 AM Second Revision No. 14-NFPA 13D-2014 [ Global Comment ] Revise the metric values throughout the standard to follow the soft conversions provided by the metric task group Supplemental Information File Name 13_Metrification_-_AUT-RSS.xlsx Description metric conversions Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Jun 20 12:12:59 EDT 2014 Committee Statement Committee Statement: Response Message: The conversions proposed for the 2016 edition will be based on a soft conversion scheme as opposed to the traditional hard conversion. The attached spreadsheet provides the proposed conversion.

2 Piping Equivalents Conversion Factors (T ) English (in.) Metric (mm) SI Unit Eng. Unit Factor 1/4 6 L gal 1 gal = L 3/8 10 mm/min gpm/ft2 1 gpm/ft2 = mm/min 1/2 15 dm3 gal 1 gal = dm3 3/4 20 Pa psi 1 psi = Pa 1 25 bar psi 1 psi = bar 1 1/4 32 Pa --> bar - 1 bar = 1E5 Pa 1 1/ /4 45 Length 2 50 SI Unit Eng. Unit Factor 2 1/2 65 m ft 1 ft = m 3 80 m in 1 in = m 3 1/2 mm in 1 in = 25.4 mm Area, Volume SI Unit Eng. Unit Factor m2 ft2 1 ft2 = m m2 in2 1 in2 = m mm2 in2 1 in2 = mm m3 ft3 1 ft3 = m mm3 in3 1 in3 = mm Other SI Unit Eng. Unit Factor kj/kg Btu/lb 1 Btu/lb = kj/kg g oz. 1 oz = g kj/m2 Btu/ft2 1 Btu/ft2 = kj/m2

3 of 36 9/22/2014 9:37 AM Second Revision No. 1-NFPA 13D-2014 [ Section No ] ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA ASTM A 53 ASTM A53/A53M, Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless, ASTM A 135 ASTM A135/A135M, Standard Specification for Electric-Resistance-Welded Steel Pipe, 2009 (2004). ASTM A 234 ASTM A234/A234M, Standard Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel for Moderate and High Temperature Service, e1. ASTM A 795 ASTM A795/A795M, Standard Specification for Black and Hot-Dipped Zinc-Coated (Galvanized) Welded and Seamless Steel Pipe for Fire Protection Use, ASTM B 32 ASTM B32, Standard Specification for Solder Metal, ASTM B 43 ASTM B43, Standard Specification for Seamless Red Brass Pipe, ASTM B 75 ASTM B75 /B75M, Standard Specification for Seamless Copper Tube, ASTM B 88 ASTM B88, Standard Specification for Seamless Copper Water Tube, ASTM B 251 ASTM B251, Standard Specification for General Requirements for Wrought Seamless Copper and Copper-Alloy Tube, ASTM B 813 ASTM B813, Standard Specification for Liquid and Paste Fluxes for Soldering Applications of Copper and Copper-Alloy Tube, 2010 (2010). ASTM B 828 ASTM B828, Standard Practice for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings, ASTM F 437 ASTM F437, Standard Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80, ASTM F 438 ASTM F438, Standard Specification for Socket-Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40, ASTM F 439 ASTM F439, Standard Specification for Socket-Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80, ASTM F 442 ASTM F442/F442M, Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR), e1. ASTM F 876 ASTM F876, Standard Specification for linked Polyethylene (PEX) Tubing, e1. Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 13:34:11 EDT 2014 Committee Statement Committee Statement: standards date updates

4 of 36 9/22/2014 9:37 AM Response Message: Public Comment No. 16-NFPA 13D-2014 [Section No ] Public Comment No. 29-NFPA 13D-2014 [Section No ]

5 of 36 9/22/2014 9:37 AM Second Revision No. 13-NFPA 13D-2014 [ Section No. 4.5 ] 4.5* Documentation. Documentation shall be available provided upon request to ensure adequate demonstrate that the water supply, listed devices, and adequate sprinkler coverage have been addressed comply with the requirements of this standard. Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 16:54:30 EDT 2014 Committee Statement Committee Statement: Response Message: The word adequate is difficult to enforce. The revised language makes the section more enforceable.

6 Second Revision No. 2-NFPA 13D-2014 [ Section No ] * Where a sprinkler is removed from a fitting or welded outlet, it shall not be reinstalled except as permitted by Dry sprinklers shall be permitted to be reinstalled, where they are not removed by applying torque at the point where the sprinkler is attached to the barrel when removed in accordance with the manufacturer s installation and maintenance instructions. Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 14:06:11 EDT 2014 Committee Statement Committee Statement: The first draft language eliminates the possibility of removing dry sprinklers with a head wrench even if the manufacturer recommends it. At least one manufacturer recommends installing and removing their dry sprinklers with a head wrench. The wording has been modified to allow the use of a head wrench if the manufacturer recommends it. Response Message: Public Comment No. 26-NFPA 13D-2014 [Section No ] Public Comment No. 27-NFPA 13D-2014 [Section No. A ] of 36 9/22/2014 9:37 AM

7 of 36 9/22/2014 9:37 AM Second Revision No. 4-NFPA 13D-2014 [ Section No ] Tanks, expansion tanks, gauges, pumps, hangers, waterflow detection devices, and valves shall not be required to be listed. Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 14:24:08 EDT 2014 Committee Statement Committee Statement: Response Message: Gauges are not always required but when they are utilized, should not be required to be listed. Public Comment No. 10-NFPA 13D-2014 [Section No ]

8 of 36 9/22/2014 9:37 AM Second Revision No. 6-NFPA 13D-2014 [ New Section after ] Small areas created by architectural features, such as planter box windows, bay windows, and similar features, shall be evaluated as follows: (1) Where no additional floor area is created by the architectural feature, no additional sprinkler protection is required. (2) Where additional floor area is created by an architectural feature, no additional sprinkler protection is required, provided all of the following conditions are met: (a) (b) (c) (d) The floor area shall not exceed 18 ft 2 (1.7 m 2 ). The floor area shall not be greater than 2 ft (0.61 m) in depth at the deepest point of the architectural feature to the plane of the primary wall where measured along the finished floor. The floor shall not be greater than 9 ft (2.7 m) in length where measured along the plane of the primary wall. Measurement from the deepest point of the architectural feature to the sprinkler shall not exceed the maximum listed spacing of the sprinkler. (3) The hydraulic design shall not be required to consider the area created by the architectural feature. Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 15:13:12 EDT 2014 Committee Statement Committee Statement: This language has long been in the annex of NFPA 13D and it is clear that additional floor area created by certain architectural features are not required to have additional sprinkler coverage. As this language is in the annex and not in the enforceable body of the standard, this intent is not consistently applied to such architectural features. Moving this language to the body of the standard will make it clear that additional sprinkler protection is not required in these small areas. As these areas are not required to be included in the hydraulic design area of the systems, these areas are distinct from shadow areas Response Message: Public Comment No. 32-NFPA 13D-2014 [New Section after ]

9 Second Revision No. 5-NFPA 13D-2014 [ Section No ] Closets. In all closets and compartments, including those housing mechanical equipment, that are smaller than 400 ft 3 (11.3 m 3 ), a single sprinkler at the highest ceiling space shall be sufficient without regard to obstructions or minimum distances to wall. pendent, upright, and sidewall residential sprinklers shall be permitted to be installed in either of the following situations: (1) Within 18 in. (460 mm) of the ceiling to avoid obstructions near the ceiling (2) at At the highest ceiling space shall be sufficient level without regard to obstructions or minimum distances to wall Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 15:03:32 EDT 2014 Committee Statement Committee Statement: Small closets, especially those housing mechanical equipment, frequently contain obstructions that make it difficult to place sprinklers within 12 inches of the ceiling. Allowing residential sprinklers to be located further down would allow adequate sprinkler protection of these small closets while avoiding ceiling level obstructions such as ducts and pipes. Based upon CFAST Computer Fire Model, an analysis was performed comparing the performance of sprinklers located 6 inches down from a ceiling in a small room to the performance of sprinklers 18 inches down from the ceiling in an even smaller closet. Based upon this analysis it appears that residential sprinklers 18 inches down from the ceiling in a closet up to 400 ft3 react to a fire at least as quickly as residential sprinklers 6 inches down from a ceiling in a small room. Using equivalency concepts, residential sprinklers could be allowed to be installed within 18 inches of the ceiling in small closets. Response Message: Public Comment No. 11-NFPA 13D-2014 [Section No ] Public Comment No. 25-NFPA 13D-2014 [New Section after 8.2.7] of 36 9/22/2014 9:37 AM

10 of 36 9/22/2014 9:37 AM Second Revision No. 8-NFPA 13D-2014 [ Section No ] Sprinklers shall not be required in clothes closets, linen closets, and pantries that meet all of the following conditions: (1) The area of the space does not exceed 24 ft 2 ( m 2 ). (2) The walls and ceilings are surfaced with noncombustible or limited-combustible materials as defined in NFPA 220. Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 16:10:13 EDT 2014 Committee Statement Committee Statement: Editorial. Delete the (3) Response Message: Public Comment No. 12-NFPA 13D-2014 [Section No ]

11 0 of 36 9/22/2014 9:37 AM Second Revision No. 9-NFPA 13D-2014 [ Section No ]

12 1 of 36 9/22/2014 9:37 AM

13 2 of 36 9/22/2014 9:37 AM Unless the pipe size is in accordance with the prescriptive pipe sizing method of , pipe shall be sized by hydraulic calculations in accordance with the methods described in NFPA 13, with the manufacturer's listed installation instructions, with , or with the following general method for straight-run systems connected to a city water main of at least 4 in. (102 mm) in diameter: The pipes shall be sized using one of the following techniques: (1) The simplified calculation method of , which can only be used for connections to a city water main of at least 4 in. (100 mm) in diameter (2) The prescritive pipe sizing method of (3) The hydraulic calculation procedure for NFPA 13 (4) The manufacturer s listed installation instructions The system flow rate shall be established in accordance with Sections 10.1 and 10.2, and it shall be determined that the flow allowed by the water meter meets or exceeds the system demand and that the total demand flow does not exceed the maximum flow allowed by the piping system components. The water pressure in the street shall be determined. Pipe sizes shall be selected. * Pressure loss for a water meter, if any, shall be determined and deducted using one of the following: Table (a) shall be permitted to be used, even where the sprinkler demand flow exceeds the meter's rated continuous flow. Higher pressure losses specified by the manufacturer shall be used in place of those specified in Table (a). Lower pressure losses shall be permitted to be used where supporting data are provided by the meter manufacturer. Pressure loss for elevation shall be deducted as follows: Building height above street (ft) = pressure loss (psi) Building height above street (m) = pressure loss (bar) * Pressure losses from the city main to the inside control valve shall be deducted by multiplying the pressure loss associated with the pipe material by the total length(s) of pipe in feet (meters). Pressure loss for piping within the building shall be deducted by multiplying the pressure loss associated with the pipe material by the total length(s) of pipe in feet (meters). Pressure loss for valves and fittings shall be deducted as follows: The valves and fittings from the control valve to the farthest sprinkler shall be counted. The equivalent length for each valve and fitting as shown in Table (b), Table (c), or Table (d) or Table (e) shall be determined and the values added to obtain the total equivalent length for each pipe size. The equivalent length for each size shall be multiplied by the pressure loss associated with the pipe material and the values totaled. In multilevel buildings, the steps in (1) through (8) shall be repeated to size piping for each floor. If the remaining pressure is less than the operating pressure established by the testing laboratory for the sprinkler being used, the sprinkler system shall be redesigned. If the remaining pressure is higher than required, smaller piping shall be permitted to be used where justified by calculations.

14 3 of 36 9/22/2014 9:37 AM The remaining piping shall be sized the same as the piping up to and including the farthest sprinkler unless smaller pipe sizes are justified by calculations. Table (a) Pressure Losses in psi in Water Meters Meter Size (in.) Flow (gpm) 18 or less * * For SI units, 1 gpm = L/min; 1 in. = 25.4 mm; 1 psi = bar. *Above maximum rated flow of commonly available meters. Table (b) Equivalent Length in Feet of Fittings and s for Schedule 40 Steel Pipe Diameter (in.) 45 Long- Radius turned degrees) straight through) Gate Angle Y Pattern Cock For SI units, 1 in. = 25.4 mm; 1 ft = m. Table (c) Equivalent Length in Feet of Fittings and s for Type K Copper Tube Diameter (in.) 45 Radius turned degrees) straight through) Gate Angle Y Pattern Cock For SI units, 1 in. = 25.4 mm; 1 ft = m. Table (d) Equivalent Length in Feet of Fittings and s for Type L Copper Tube Diameter (in.) 45 Long- Long- Radius turned degrees) straight through) Gate Angle Y Pattern Cock Check Check Check

15 4 of 36 9/22/2014 9:37 AM Diameter (in.) 45 Long- Radius turned degrees) straight through) Gate Angle Y Pattern Cock For SI units, 1 in. = 25.4 mm; 1 ft = m. Table (e) Equivalent Length in Feet of Fittings and s for Type M Copper Tube Diameter (in.) 45 Long- Radius turned degrees) straight through) Gate Angle Y Pattern Cock For SI units, 1 in. = 25.4 mm; 1 ft = m. Check Check Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 16:11:08 EDT 2014 Committee Statement Committee Statement: Section , as written is confusing and not "user friendly". This revision seeks to simplify and clarify the acceptable methods for sizing sprinkler pipes for NFPA 13D systems. This comment's does not change the existing requirements of this section, but instead changes the requirements from paragraph form to a list form for ease of interpretation. The 12 step general method originally included in section has been retained but renumbered as section Response Message: Public Comment No. 23-NFPA 13D-2014 [Section No ]

16 5 of 36 9/22/2014 9:37 AM Second Revision No. 15-NFPA 13D-2014 [ Section No ]

17 6 of 36 9/22/2014 9:37 AM * General Pipe Sizing Method.

18 7 of 36 9/22/2014 9:37 AM Smaller pipe sizes than those determined by shall be permitted where justified by calculations for systems connected to city water mains of at least 4 in. (102 mm) in diameter. The following is the general pipe sizing method for straight-run systems connected to a city water main of at least 4 in. (100 mm) in diameter in accordance with (1) : (1) The system flow rate shall be established in accordance with Sections 10.1 and 10.2, and it shall be determined that the flow allowed by the water meter meets or exceeds the system demand and that the total demand flow does not exceed the maximum flow allowed by the piping system components. (2) The water pressure in the street shall be determined. (3) Pipe sizes shall be selected. (4) * Pressure loss for a water meter, if any, shall be determined and deducted using one of the following: (a) (b) (c) Table (a) Table (a)Table (a) shall be permitted to be used, even where the sprinkler demand flow exceeds the meter's rated continuous flow. Higher pressure losses specified by the manufacturer shall be used in place of those specified in Table (a) Table (a)Table (a). Lower pressure losses shall be permitted to be used where supporting data are provided by the meter manufacturer. (5) Pressure loss for elevation shall be deducted as follows: (a) (b) Building height above street (ft) = pressure loss (psi) Building height above street (m) = pressure loss (bar) (6) * Pressure losses from the city main to the inside control valve shall be deducted by multiplying the pressure loss associated with the pipe material by the total length(s) of pipe in feet (meters). (7) Pressure loss for piping within the building shall be deducted by multiplying the pressure loss associated with the pipe material by the total length(s) of pipe in feet (meters). (8) Pressure loss for valves and fittings shall be deducted as follows: (a) (b) (c) The valves and fittings from the control valve to the farthest sprinkler shall be counted. The equivalent length for each valve and fitting as shown in Table (b) Table (b)Table (b), Table (c) Table (c)Table (c), or Table (d) Table (d)Table (d) or Table (e) Table (e)Table (e) shall be determined and the values added to obtain the total equivalent length for each pipe size. The equivalent length for each size shall be multiplied by the pressure loss associated with the pipe material and the values totaled. (9) In multilevel buildings, the steps in (1) (1) through (8) (8) shall be repeated to size piping for each floor. (10) If the remaining pressure is less than the operating pressure established by the testing laboratory for the sprinkler being used, the sprinkler system shall be redesigned. (11) If the remaining pressure is higher than required, smaller piping shall be permitted to be used where justified by calculations. (12) The remaining piping shall be sized the same as the piping up to and including the farthest sprinkler unless smaller pipe sizes are justified by calculations. Table (a) Pressure Losses in psi in Water Meters Meter Size Flow (gpm) (in.) 18 or less * *

19 8 of 36 9/22/2014 9:37 AM Meter Size (in.) Flow (gpm) 18 or less For SI units, 1 gpm = L/min; 1 in. = mm; 1 psi = bar. *Above maximum rated flow of commonly available meters. Table (b) Equivalent Length in Feet of Fittings and s for Schedule 40 Steel Pipe Diameter (in.) 45 Long- Radius turned degrees) straight through) Gate Angle Y Pattern Cock For SI units, 1 in. = mm; 1 ft = m. Table (c) Equivalent Length in Feet of Fittings and s for Type K Copper Tube Diameter (in.) 45 turned degrees) straight through) Gate Angle Y Pattern Cock For SI units, 1 in. = mm; 1 ft = m. Table (d) Equivalent Length in Feet of Fittings and s for Type L Copper Tube Diameter (in.) 45 Long- Radius Long- Radius turned degrees) straight through) Gate Angle Y Pattern Cock For SI units, 1 in. = mm; 1 ft = m. Table (e) Equivalent Length in Feet of Fittings and s for Type M Copper Tube Check Check Check Diameter (in.) 45 Long- Radius Gate Angle Y Pattern Cock Check

20 9 of 36 9/22/2014 9:37 AM turned degrees) straight through) For SI units, 1 in. = mm; 1 ft = m. Supplemental Information File Name SR-15_Tables.docx Description Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Jun 20 12:17:20 EDT 2014 Committee Statement Committee Statement: Response Message: The general method of pipe sizing has been moved from section to to correlate with SR-9. The wording and method itself remains unchanged. Public Comment No. 19-NFPA 13D-2014 [Section No ]

21 Table (a) Pressure Losses in psi in Water Meters Meter Size Flow (gpm) (in.) 18 or less ⅝ * ¾ * ½ For SI units, 1 gpm = L/min; 1 in. = 25.4 mm; 1 psi = bar. *Above maximum rated flow of commonly available meters. Table (b) Equivalent Length in Feet of Fittings and s for Schedule 40 Steel Pipe Diameter (in.) 45 Long- Radius turned degrees) straight through) Gate Angle Y Cock Check Pattern ¼ ½ For SI units, 1 in. = 25.4 mm; 1 ft = m.

22 Table (c) Equivalent Length in Feet of Fittings and s for Type K Copper Tube Diameter (in.) 45 Long- Radius turned degrees) straight through) Gate Angle Y Cock Check Pattern ¾ ¼ ½ For SI units, 1 in. = 25.4 mm; 1 ft = m. Table (d) Equivalent Length in Feet of Fittings and s for Type L Copper Tube Diameter (in.) 45 Long- Radius turned degrees) straight through) Gate Angle Y Cock Check Pattern ¾ ¼ ½ For SI units, 1 in. = 25.4 mm; 1 ft = m.

23 Table (e) Equivalent Length in Feet of Fittings and s for Type M Copper Tube Diameter (in.) 45 Long- Radius turned degrees) straight through) Gate Angle Y Cock Check Pattern ¾ ¼ ½ For SI units, 1 in. = 25.4 mm; 1 ft = m.

24 Second Revision No. 10-NFPA 13D-2014 [ Section No ] Any sprinkler that is operated, damaged, corroded, covered with foreign materials, or showing signs of leakage shall be replaced with a new listed sprinkler having the same performance characteristics as the original equipment * Where replacing residential sprinklers manufactured prior to 2003 and that are no longer available from the manufacturer and are installed using a design density less than 0.05 gpm/ft 2 (204 mm/min), a residential sprinkler with an equivalent K-factor (± 5%) shall be permitted to be used provided the currently listed coverage area for the replacement sprinkler is not exceeded. Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 16:20:10 EDT 2014 Committee Statement Committee Statement: It is preferred to replace existing sprinklers with the same model when it is available so that the systems continue to operate as it was designed. Response Message: Public Comment No. 13-NFPA 13D-2014 [Section No ] Public Comment No. 17-NFPA 13D-2014 [Section No ] Public Comment No. 24-NFPA 13D-2014 [Section No ] Public Comment No. 30-NFPA 13D-2014 [Section No ] 0 of 36 9/22/2014 9:37 AM

25 1 of 36 9/22/2014 9:37 AM Second Revision No. 3-NFPA 13D-2014 [ Section No. A ] A Provided dry sprinklers are removed by utilizing a pipe wrench on the barrel, where permitted by the manufacturer, they can be reinstalled. If a dry sprinkler is removed by utilizing the sprinkler wrench on the boss of the sprinkler, the dry sprinkler should not be reinstalled. Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 14:16:13 EDT 2014 Committee Statement Committee Statement: Response Message: This annex section is no longer warranted due to the change to which addresses the allowance to reinstall dry sprinklers that were removed in accordance with the manufacturers maintenance and installation requirements.

26 2 of 36 9/22/2014 9:37 AM Second Revision No. 12-NFPA 13D-2014 [ Section No. A.6.2 ]

27 3 of 36 9/22/2014 9:37 AM A.6.2

28 4 of 36 9/22/2014 9:37 AM The connection to city mains for fire protection is often subject to local regulation of metering and backflow prevention requirements. Preferred and acceptable water supply arrangements are shown in Figure A.6.2(a)through Figure A.6.2(d). Where it is necessary to use a meter between the city water main and the sprinkler system supply, an acceptable arrangement as shown in Figure A.6.2(c)and Figure A.6.2(d)can be used. Under these circumstances, the flow characteristics of the meter are to be included in the hydraulic calculation of the system [see Table (a)]. Where a tank is used for both domestic and fire protection purposes, a low water alarm that actuates when the water level falls below 110 percent of the minimum quantity specified in should be provided. The effect of pressure-reducing valves on the system should be considered in the hydraulic calculation procedures. Figure A.6.2(a), Figure A.6.2(c), or Figure A.6.2(d)are acceptable methods for getting the water supply into the unit for a stand-alone sprinkler system (one that does not also provide direct connections to the cold water fixtures) because the common supply pipe for the domestic system and the sprinkler system between the water supply and the dwelling unit has a single control valve that shuts the sprinkler system, which helps to ensure that people who have running water to their domestic fixtures also have fire protection. This serves as a form of supervision for the control valve and can be used to make sure that the valve stays open in place of other, more expensive options such as tamper switches with a monitoring service. Some water utilities insist on separate taps and supply pipes from the water supply to the dwelling unit for fire sprinkler systems as shown in Figure A.6.2(d), due to concerns about shutting off the water supply for nonpayment of bills and the desire not to shut off fire protection if this ever occurs. While these types of arrangements are acceptable, they might not be cost efficient and should be discouraged due to the extra cost burden this places on the building owner. The concern over shutting off the water for nonpayment of bills is a nonissue for a number of reasons. First, the water utilities rarely actually shut off water for nonpayment. Second, if they do shut off water for nonpayment, they are creating violations of all sorts of health and safety codes, allowing people to live in a home without running water. Concern over the fire protection for those individuals when they are violating all kinds of other health codes is disingenuous. More likely, the water utility will not shut off the water and will follow other legal avenues to collect on unpaid bills, such as liens on property. Millions of people should not have to pay hundreds of millions of dollars to install separate water taps and lines for the few services that might get shut off. Figure A.6.2(a) Minimum Requirements for a Stand-Alone System. Figure A.6.2(b) Acceptable Arrangement for Stand-Alone Piping Systems Option 1.

29 5 of 36 9/22/2014 9:37 AM Figure A.6.2(c) Acceptable Arrangement for Stand-Alone Piping System Option 2.

30 6 of 36 9/22/2014 9:37 AM Figure A.6.2(d) Acceptable Arrangement for Stand-alone Piping Systems Option 3. Supplemental Information File Name NFPA_13D_F.A.6.2_b_.pdf NFPA_13D_F.A.6.2_c_and_d_.pdf G13D-6r2.jpg G13D-7r2.jpg G13D-55r1.jpg Description Fig A.6.2(b) Fig A.6.2(c) and (d) Fig A.6.2(b)-rev Fig A.6.2(c)-rev Fig A.6.2(d)-rev

31 7 of 36 9/22/2014 9:37 AM Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 16:46:22 EDT 2014 Committee Statement Committee Statement: Response Message: Figures A.6.2(b), (c), and (d) have been revised to more accurately reflect the recommended location for the system gauges.

32

33

34

35

36

37 8 of 36 9/22/2014 9:37 AM Second Revision No. 7-NFPA 13D-2014 [ Section No. A ] Global SR-14

38 9 of 36 9/22/2014 9:37 AM A.8.2.5

39 0 of 36 9/22/2014 9:37 AM The objective is to position sprinklers so that the response time and discharge are not unduly affected by obstructions such as ceiling slope, beams, light fixtures, or ceiling fans. The rules in this section, while different from the obstruction rules of NFPA 13, provide a reasonable level of life safety while maintaining the philosophy of keeping NFPA 13D relatively simple to apply and enforce. Fire testing has indicated the need to wet walls in the area protected by residential sprinklers at a level closer to the ceiling than that accomplished by standard sprinkler distribution. Where beams, light fixtures, sloped ceilings, and other obstructions occur, additional residential sprinklers are necessary to achieve proper response and distribution. In addition, for sloped ceilings, higher flow rates could be needed. Guidance should be obtained from the manufacturer. A series of 33 full-scale tests were conducted in a test room with a floor area of 12 ft 24 ft ( m 7.2 m) to determine the effect of cathedral (sloped) and beamed ceiling construction, and combinations of both, on fast-response residential sprinkler performance. The testing was performed using one pendent-type residential sprinkler model, two ceiling slopes (0 degrees and 14 degrees), and two beam configurations on a single enclosure size. In order to judge the effectiveness of sprinklers in controlling fires, two baseline tests, in which the ceiling was smooth and horizontal, were conducted with the pendent sprinklers installed and with a total water supply of 26 gpm ( L/min) as required by this standard. The results of the baseline tests were compared with tests in which the ceiling was beamed or sloped, or both, and two pendent sprinklers were installed with the same water supply. Under the limited conditions used for testing, the comparison indicates that sloped or beamed ceilings, or a combination of both, represent a serious challenge to the fire protection afforded by fast-response residential sprinklers. However, further tests with beamed ceilings indicated that fire control equivalent to that obtained in the baseline tests can be obtained where one sprinkler is centered in each bay formed by the beams and a total water supply of 36 gpm ( L/min) is available. Fire control equivalent to that obtained in the baseline tests was obtained for the smooth, sloped ceiling tests where three sprinklers were installed with a total water supply of 54 gpm ( L/min). In a single smoldering-started fire test, the fire was suppressed. Small areas created by architectural features such as planter box windows, bay windows, and similar features can be evaluated as follows: Where no additional floor area is created by the architectural feature, no additional sprinkler protection is required. Where additional floor area is created by an architectural feature, no additional sprinkler protection is required, provided all of the following conditions are met: The floor area does not exceed 18 ft 2 (1.7 m 2 ). The floor area is not greater than 2 ft (0.65 m) in depth at the deepest point of the architectural feature to the plane of the primary wall where measured along the finished floor. The floor area is not greater than 9 ft (2.9 m) in length where measured along the plane of the primary wall. Measurement from the deepest point of the architectural feature to the sprinkler should not exceed the maximum listed spacing of the sprinkler. The hydraulic design is not required to consider the area created by the architectural feature. Where the obstruction criteria established by this standard are followed, sprinkler spray patterns will not necessarily get water to every square foot of space within a room. As such, a sprinkler in a room with acceptable obstructions as outlined in this standard might not be capable of passing the fire test (specified by ANSI/UL 1626, Residential Sprinklers for Fire-Protection Service, and other similar laboratory standards) if the fire is started in one of these dry areas. This occurrence is not to be interpreted as a failure of the sprinkler. The laboratory fire tests are sufficiently challenging to the sprinkler without additional obstructions as a safety factor to account for the variables that actually occur in dwellings, including acceptable obstructions to spray patterns. The rules on and were developed from a testing series conducted by the National Fire Sprinkler Association and The Viking Corporation that included fire modeling, sprinkler response tests, sprinkler distribution tests, and full-scale fire tests (Valentine and Isman, Interaction of Residential Sprinklers, Ceiling Fans and Similar Obstructions, National Fire Sprinkler Association, November 2005 ). This test series, along with additional industry experience, shows that a difference exists between obstructions that are tight to the ceiling and obstructions that hang down from the ceiling, allowing spray over the top. Residential sprinklers require high wall wetting, which means that they tend to spray over

40 1 of 36 9/22/2014 9:37 AM obstructions that hang down from the ceiling. The test series showed that the fan blades were not significant obstructions and that as long as the sprinkler was far enough from the fan motor housing (measured from the center of the housing), the sprinkler could control a fire on the other side of the fan in a small room. In larger rooms, the sprinkler will need to be augmented by additional sprinklers on the other side of the fan. The test series showed that the fan on low or medium speed did not make a significant difference in sprinkler performance. On high speed (pushing air down), the fan did impact sprinkler performance, but fire control was still achieved in small rooms. In larger rooms, it is expected that additional sprinklers would be installed. The test series also showed that the fan blowing down was more significant than the fan pulling air up. The rules in were developed from years of experience with obstruction rules and an additional test series conducted by the National Fire Sprinkler Association with the help of Tyco International (Valentine and Isman, Kitchen Cabinets and Residential Sprinklers, National Fire Sprinkler Association, November 2005 ), which included fire modeling, distribution tests, and full-scale fire tests. The test series showed that pendent sprinklers definitely provide protection for kitchens, even for fires that start under the cabinets. The information in the series was less than definitive for sidewall sprinklers, but distribution data show that sprinklers in the positions in this standard provide adequate water distribution in front of the cabinets and that sidewall sprinklers should be able to control a fire that starts under the cabinets. When protecting kitchens or similar rooms with cabinets, the pendent sprinkler should be the first option. If pendent sprinklers cannot be installed, the next best option is a sidewall sprinkler on the opposite wall from the cabinets, spraying in the direction of the cabinets. The third best option is the sidewall sprinkler on the same wall as the cabinets on a soffit flush with the face of the cabinet. The last option should be putting sprinklers on the wall back behind the face of the cabinet because this location is subject to being blocked by items placed on top of the cabinets. It is not the intent of the committee to require sprinklers to be installed under kitchen cabinets. Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 15:15:43 EDT 2014 Committee Statement Committee Statement: Response Message: The annex language being deleted from this section is being moved to a new section in Public Comment No. 4-NFPA 13D-2014 [Section No. A.8.2.5] Public Comment No. 31-NFPA 13D-2014 [Section No. A.8.2.5]

41 2 of 36 9/22/2014 9:37 AM Second Revision No. 11-NFPA 13D-2014 [ Section No. A ]

42 3 of 36 9/22/2014 9:37 AM A

43 4 of 36 9/22/2014 9:37 AM The determination of public water supply pressure should take into account the probable minimum pressure conditions prevailing during such periods as during the night or during the summer months when heavy usage can occur. The possibility of interruption by floods or ice conditions in winter also should be considered. [See Figure A (a), Figure A (b), Table A (a), Table A (b), Table A (c), and Table A (d).] Figure A (a) Calculation Sheet. Figure A (b) Calculation Sheet Elevated Tank, Booster Pump, Pump Tank Supply. Table A (a) Pressure Losses in psi/ft for Schedule 40 Steel Pipe (C = 120) Pipe Size (in.) Flow Rate (gpm)

44 5 of 36 9/22/2014 9:37 AM For SI units, 1 gal = L; 1 psi = bar; 1 in. = 25.4 mm; 1 ft = m. Table A (b) Pressure Losses in psi/ft for Copper Tubing Types K, L, and M (C = 150) Flow Rate (gpm) Tubing Size (in.) Type M L K M L K M L K M L K M L K For SI units, 1 gal = L; 1 psi = bar; 1 in. = 25.4 mm; 1 ft = m. Table A (c) Pressure Losses in psi/ft for CPVC Pipe (C = 150) Nominal Pipe Size (in.) Actual Pipe Size (in.) Flow Rate (gpm) Table A (d) Pressure Losses in psi/ft for PEX Pipe (C = 150) Nominal Pipe Size (in.) Actual Pipe Size (in.) Flow Rate (gpm) Submitter Information Verification

45 6 of 36 9/22/2014 9:37 AM Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 16:30:28 EDT 2014 Committee Statement Committee Statement: These Annex notes have been renumbered to correlate with public comment 19 and 20. Response Message: Public Comment No. 21-NFPA 13D-2014 [Section No. A ]

Public Comment No. 16-NFPA 13D-2014 [ Section No ]

Public Comment No. 16-NFPA 13D-2014 [ Section No ] of 52 9/22/2014 9:20 AM Public Comment No. 16-NFPA 13D-2014 [ Section No. 2.3.3 ] 2.3.3 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM

More information

Review of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings

Review of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings Review of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings Reprinted with permission from NFPA 13D Installation of Sprinkler Systems in One- and two-family Dwellings and Manufactured

More information

Committee Input No. 28-NFPA 13R-2013 [ Global Input ]

Committee Input No. 28-NFPA 13R-2013 [ Global Input ] Page 1 of 6 Committee Input No. 28-NFPA 13R-2013 [ Global Input ] 6.2.2 Outside Dwelling Units. 6.2.2.1 All sprinklers used outside of the dwelling units shall be in accordance with 6.2.2 7.2 and 7.3.

More information

2009 International Residential Code Draft of New Fire Sprinkler Related Requirements

2009 International Residential Code Draft of New Fire Sprinkler Related Requirements 1. IRC Sections R313 and R314, insert two new sections as follows: R313 FIRE SPRINKLER SYSTEM FOR TOWNHOUSES R313.1 Required Installation. An automatic residential fire sprinkler system shall be installed

More information

Second Revision No. 2-NFPA [ Section No ]

Second Revision No. 2-NFPA [ Section No ] Page 1 of 8 Second Revision No. 2-NFPA 410-2014 [ Section No. 10.2 ] 10.2* Fire Extinguishers. In addition to extinguishers required by NFPA 409, extinguishers shall be provided for aircraft maintenance

More information

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur.

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur. First Revision No. 1-NFPA 501-2015 [ Section No. 5.3.1.3 ] 5.3.1.3 The following conditions shall be met when an interior finish material is tested using the test protocol of NFPA 286, Standard Methods

More information

freedom residential flush pendent sprinkler vk476 (K4.9)

freedom residential flush pendent sprinkler vk476 (K4.9) January 6, 2010 Sprinkler 145h 1. DESCRIPTION Viking Freedom Residential Flush Pendent Sprinkler VK476 is a small high-sensitivity fusible element residential sprinkler designed for installation on concealed

More information

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK457 (K4.9) TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK457 (K4.9) TECHNICAL DATA September 5, 2008 Sprinkler 147u 1. DESCRIPTION Viking Freedom Residential Concealed Pendent Sprinkler VK457 is a small highsensitivity solder link and lever residential sprinkler designed for installation

More information

1 of /3/ :03 PM. Public Input No. 1-NFPA 13D-2015 [ Chapter 2 ]

1 of /3/ :03 PM. Public Input No. 1-NFPA 13D-2015 [ Chapter 2 ] 1 of 129 11/3/2016 12:03 PM Public Input No. 1-NFPA 13D-2015 [ Chapter 2 ] 2 of 129 11/3/2016 12:03 PM American Society of Mechanical Engineers Chapter 2 Referenced Publications 2.1 General. The documents

More information

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA Page of 5. DESCRIPTION Viking EC/QREC Ordinary Hazard ELO Fusible Element Sprinkler VK535 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings to meet varying

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: Technical Committee on Residential Sprinkler

More information

Zurn Pex, Inc. Residential Fire Protection Presentation. PEX Plumbing, Radiant Heating and Residential Fire Protection Systems

Zurn Pex, Inc. Residential Fire Protection Presentation. PEX Plumbing, Radiant Heating and Residential Fire Protection Systems Residential Fire Protection Presentation Zurn Pex, Inc PEX Plumbing, Radiant Heating and Residential Fire Protection Systems Matt Lawrence BDM-North Central Region 1 Presentation Outline I. IRC Mandate

More information

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA Page 1 of 6 1. DESCRIPTION Viking Standard/Quick Response Extended Coverage Ordinary Hazard (ECOH) Pendent Sprinkler VK572 is a thermosensitive glass bulb spray sprinkler with a 14.0 (202 metric*) nominal

More information

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA Page 1 of 5 1. DESCRIPTION Viking EC/QREC Ordinary Hazard ELO Fusible Element Pendent Sprinkler VK537 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings

More information

WORKING DRAFT OF COMMITTEE MEETING OUTPUT

WORKING DRAFT OF COMMITTEE MEETING OUTPUT WORKING DRAFT OF COMMITTEE MEETING OUTPUT CONTENT NOT FINAL SUBJECT TO REVISION PRIOR TO LETTER BALLOT AND PUBLICATION OF SECOND DRAFT REPORT Document: NFPA 221 Revision Cycle: A2014 Meeting Date: 5/20/2013

More information

Second Revision No. 20-NFPA [ Section No. 1.4 ] Supplemental Information. Submitter Information Verification. Committee Statement

Second Revision No. 20-NFPA [ Section No. 1.4 ] Supplemental Information. Submitter Information Verification. Committee Statement Second Revision No. 20-NFPA 14-2015 [ Section No. 1.4 ] 1.4* Equivalency. Nothing in this standard is intended to prevent the use of systems, methods, or devices of equivalent or superior quality, strength,

More information

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] 1.3 Application. 1.3.1 This standard shall apply to all systems for the movement of environmental air in structures that serve the following, except

More information

Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification Public Input No. 4-NFPA 496-2014 [ Section No. 5.2.2 ] 5.2.2 Where When the enclosure has been opened or if the protective gas supply has failed to maintain the required positive pressure, the enclosure

More information

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040 Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040 SPRINKLER SHOP DRAWINGS 2007 NFPA 13 and 2007 NFPA 24 Project: Listed items require sprinkler

More information

ATTIC UPRIGHT SPECIFIC APPLICATION SPRINKLER VK696 TECHNICAL DATA

ATTIC UPRIGHT SPECIFIC APPLICATION SPRINKLER VK696 TECHNICAL DATA Page 1 of 7 1. DESCRIPTION The Viking Attic Upright VK696 is a specific application concealed space sprinkler that provides superior fire protection in combustible and non-combustible sloped attic spaces

More information

standard/quick response extended coverage light and ordinary hazard elo sprinklers

standard/quick response extended coverage light and ordinary hazard elo sprinklers January 27, 2012 Sprinkler 83a 1. DESCRIPTION Viking EC/QREC Light and Ordinary Hazard Extra-Large Orifice Sprinklers VK532 and VK534 are thermosensitive spray sprinklers available in several different

More information

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design) Page:1 of 5 Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design) General Description The Model HF-RES Residential Flush Horizontal Side-Wall

More information

Public Comment No. 20-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

Public Comment No. 20-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item of 27 9/2/2014 9:27 AM Public Comment No. 20-NFPA 24-2014 [ Section No. 2.3.2 ] 2.3.2 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM

More information

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0) Sprinkler 83h 1. DESCRIPTION Viking Standard/Quick Response Extended Coverage Ordinary Hazard (ECOH) Upright Sprinkler VK570 and Pendent Sprinkler VK572 are thermosensitive glass bulb spray sprinklers

More information

Public Comment No. 2-NFPA [ Section No ]

Public Comment No. 2-NFPA [ Section No ] Public Comment No. 2-NFPA 16-2013 [ Section No. 3.3.6 ] 3.3.6* Foam-Water Sprinkler System. A piping network connected to a source of foam concentrate and to a water supply. The piping network is equipped

More information

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA October 4, 2007 Sprinkler 149m Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Freedom Residential Pendent Sprinkler VK468

More information

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM 1 of 14 6/22/2016 3:15 PM Second Revision No. 1-NFPA 17A-2016 [ Section No. 4.3.3 ] 4.3.3 All discharge nozzles shall be provided with caps or other suitable devices to prevent the entrance of grease vapors,

More information

EC/QREC ORDINARY HAZARD UPRIGHT SPRINKLER VK570 (K14.0) TECHNICAL DATA

EC/QREC ORDINARY HAZARD UPRIGHT SPRINKLER VK570 (K14.0) TECHNICAL DATA Page 1 of 5 1. DESCRIPTION Viking Standard/Quick Response Extended Coverage Ordinary Hazard (ECOH) Upright Sprinkler VK570 is a thermosensitive glass bulb spray sprinkler with a 14.0 (202 metric*) nominal

More information

First Revision No. 6-NFPA [ Section No. 2.2 ]

First Revision No. 6-NFPA [ Section No. 2.2 ] Page 1 of 18 First Revision No. 6-NFPA 555-2014 [ Section No. 2.2 ] 2.2 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471. NFPA 12, Standard on Carbon

More information

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description Sprinklers (TY2284) are decorative, fast response, fusible solder sprinklers

More information

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM 1 of 11 1/18/2016 5:43 PM First Revision No. 2-NFPA 51-2015 [ Global Input ] Throughout standard remove references to the following and replace with the following: (1) CGA C-7 Guide to Precautionary Labelling

More information

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description Page:1 of 5 SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description The Model ZN-RES Residential Flush Pendent

More information

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description Worldwide Contacts www.tyco-fire.com Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K and Pendent Extended Coverage Light and Ordinary Hazard General Description TYCO Series EC-11 and EC-14 Extended

More information

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems General Description LFII Residential Flush Horizontal Sidewall

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE May 4, 2007 Sprinkler 149a 1. PRODUCT DESCRIPTION Viking Freedom Residential Pendent Sprinkler VK438 is a small, thermosensitive, glass-bulb residential sprinkler available in several different finishes

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE May 4, 2007 Sprinkler 140j 1. PRODUCT DESCRIPTION Viking Freedom Residential Pendent Sprinkler VK436 is a small, thermosensitive, glass-bulb residential sprinkler available in several different finishes

More information

RESIDENTIAL SPRINKLER INSTALLATION GUIDE

RESIDENTIAL SPRINKLER INSTALLATION GUIDE RESIDENTIAL SPRINKLER INSTALLATION GUIDE 4077 AIR PARK DRIVE STANDISH, MICHIGAN 48658 PHONE 989-846-4583 800-248-0278 FAX 989-846-9231 www.globesprinkler.com A-15 GLOBE RESIDENTIAL SPRINKLER GUIDE DESCR.,

More information

Page 1 of 15 Second Revision No. 8-NFPA 82-2013 [ Section No. 2.2 ] 2.2 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471. NFPA 13, Standard for the Installation

More information

NFPA 30 FLC-SWC First Revisions Page 1 of 10 11/6/2015 9:21 AM. First Revision No. 208-NFPA [ Section No ]

NFPA 30 FLC-SWC First Revisions Page 1 of 10 11/6/2015 9:21 AM. First Revision No. 208-NFPA [ Section No ] of 46 11/6/2015 9:21 AM First Revision No. 208-NFPA 30-2015 [ Section No. 9.3.3.1 ] 9.3.3.1 Storage of liquids shall not physically obstruct a means of egress. Submittal Date: Wed Sep 09 18:24:20 EDT 2015

More information

Public Comment No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment. Submitter Information Verification

Public Comment No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment. Submitter Information Verification Public Comment No. 2-NFPA 73-2014 [ Section No. 4.1.3 ] 4.1.3 Unused Openings. 4.1.3.1 Unused openings, other than those intended for the operation of equipment, those intended for mounting purposes, or

More information

9/23/ :20 AM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

9/23/ :20 AM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification of 4 9/23/2016 10:20 AM Second Revision No. 6501-NFPA 5000-2016 [ Section No. 17.2.2.2.4 ] 17.2.2.2.4* Classroom Door Locking to Prevent Unwanted Entry. Classroom doors shall be permitted to be locked

More information

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description Page:1 of 7 SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description The Model ZN-RES Residential Flush Pendent

More information

SENJU SPRINKLER CO., LTD.

SENJU SPRINKLER CO., LTD. Page:1 of 8 SENJU SPRINKLER CO., LTD. Residential, Pendent Sprinkler Model FR-RES K-Factor: 4.9 SIN: SS4451 GENERAL DESCRIPTION The Model FR-RES Residential Pendent and Recessed Pendent Sprinklers are

More information

culus Listed: Category VNIV Refer to the Approval Chart on page 3. VK697 Attic Upright Sprinkler Specifications:

culus Listed: Category VNIV Refer to the Approval Chart on page 3. VK697 Attic Upright Sprinkler Specifications: Page 1 of 8 1. DESCRIPTION The Viking Attic Upright VK697 is a specific application attic sprinkler that provides superior fire protection in combustible and non-combustible sloped attic spaces when used

More information

Second Revision No. 3-NFPA [ Section No. 2.3 ]

Second Revision No. 3-NFPA [ Section No. 2.3 ] Second Revision No. 3-NFPA 804-2014 [ Section No. 2.3 ] 2.3 Other Publications. 2.3.1 ASME Publications. American Society of Mechanical Engineers, Three Park Avenue, New York, NY 10016-5990. ASME Boiler

More information

26 of 128 9/23/2014 9:25 AM

26 of 128 9/23/2014 9:25 AM 26 of 128 9/23/2014 9:25 AM Second Revision No. 105-NFPA 72-2014 [ Global Comment ] Revise the Annex F figures that include a smoke detector symbol (hexagon with a whisp of smoke) so that the new smoke

More information

MONTECITO FIRE PROTECTION DISTRICT

MONTECITO FIRE PROTECTION DISTRICT Section 5a MONTECITO FIRE PROTECTION DISTRICT FIRE PROTECTION PLAN Residential Automatic Fire Sprinkler System Installations I Automatic Fire Sprinkler System Standards 1. Definition and Standard: An automatic

More information

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA Page of 5. DESCRIPTION Viking Horizon Standard Response Flush Pendent Sprinkler VK400 is a small, flush, solder link and lever spray sprinkler. Designed for use with concealed piping, the unit is mounted

More information

Model F1 Residential Sprinklers for Design Density of.10 gpm/ft 2

Model F1 Residential Sprinklers for Design Density of.10 gpm/ft 2 Model F1 Res s engineered for the lowest flows to meet the minimum design density of.05 gpm/ft 2 Types: 1. F1 Res 49 Pendent 2. F1 Res 49 Recessed Pendent/F1 3. F1 Res 49 Recessed Pendent/FP 4. F1 Res

More information

Fire Prevention Coffee Break Training. May 2017

Fire Prevention Coffee Break Training. May 2017 Fire Prevention Coffee Break Training May 2017 Agenda Introduction Submittals - Phelan Changes to NFPA 13 - Phelan Questions and Answers Open Forum Please welcome our S ummer Intern Charlie Poppe Small

More information

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing. 9/20/2016 2:27 PM Second Revision No. 5006-NFPA 101-2016 [ Section No. 3.3.56 ] 3.3.56 Delayed Action Closer. Self-closing device that incorporates a delay prior to the initiation of closing. Mechanical

More information

mirage standard response concealed pendent sprinkler vk492 (K5.6)

mirage standard response concealed pendent sprinkler vk492 (K5.6) Page 1 of 6 1. DESCRIPTION Viking Mirage Standard Response Concealed Pendent Sprinkler VK492 is a thermosensitive glass-bulb spray sprinkler designed for installation on concealed pipe systems where the

More information

SAF-BCF SECOND REVISIONS WITH STATEMENTS

SAF-BCF SECOND REVISIONS WITH STATEMENTS Page 196 of 331 32.2.1.3 ] Second Revision No. 153-NFPA 101-2013 [ New Section after 32.2.1.4 Multiple-Level Buildings. For purposes of applying requirements of this chapter that utilize the term level

More information

9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification Second Revision No. 2011-NFPA 101-2016 [ Section No. 14.2.2.2.4 ] 14.2.2.2.4* Classroom Door Locking to Prevent Unwanted Entry. Classroom doors shall be permitted to be locked to prevent unwanted entry

More information

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved. Public Input No. 1-NFPA 557-2012 [ New Section after 1.5.3 ] 1.6 Approved Qualifications The design shall be prepared by a person with qualifications acceptable to the AHJ. The term designer is used in

More information

freedom residential Upright sprinkler vk467 (k4.9)

freedom residential Upright sprinkler vk467 (k4.9) Page 1 of 6 1. DESCRIPTION Viking Freedom Residential Upright Sprinkler VK467 is a small, thermosensitive, glassbulb residential sprinkler available in several different finishes and temperature ratings

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE November 2, 2007 Sprinkler 113a 1. DESCRIPTION The Viking Standard Response High Challenge Upright Large-Drop Sprinkler VK540 is a thermosensitive, glass-bulb sprinkler intended for use in protecting high

More information

Page 1 of 19 Committee Input No. 14-NFPA 33-2013 [ Global Input ] Type your content here... Supplemental Information File Name IndoorDraftforCI.docx Description This committee input would be added to new

More information

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed. Page of 5. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Pendent Sprinkler VK506 incorporates the capability to suppress specific high-challenge fires. The addition of a larger K-Factor allows

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE March 2, 2007 Sprinkler 147k 1. DESCRIPTION Viking Freedom Residential Concealed Pendent Sprinkler VK425 is small a highsensitivity solder link and lever residential sprinkler designed for installation

More information

NZS 4517:2010. New Zealand Standard. Fire sprinkler systems for houses. Superseding NZS 4517:2002 NZS 4517:2010

NZS 4517:2010. New Zealand Standard. Fire sprinkler systems for houses. Superseding NZS 4517:2002 NZS 4517:2010 New Zealand Standard Fire sprinkler systems for houses Superseding NZS 4517:2002 NZS 4517:2010 NZS 4517:2010 COMMITTEE REPRESENTATION This Standard was prepared under the supervision of the P 4517 Committee,

More information

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK534 (K11.2)

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK534 (K11.2) Page 1 of 6 1. DESCRIPTION Viking EC/QREC Pendent Sprinkler VK534 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings to meet varying design requirements.

More information

RESIDENTIAL SPRINKLER INSTALLATION GUIDE

RESIDENTIAL SPRINKLER INSTALLATION GUIDE RESIDENTIAL SPRINKLER INSTALLATION GUIDE 4077 AIR PARK DRIVE STANDISH, MICHIGAN 48658 PHONE 989-846-4583 800-248-0278 FAX 989-846-9231 www.globesprinkler.com AUGUST 2014 A-15 GLOBE RESIDENTIAL SPRINKLER

More information

MSC Guidelines for Automatic Sprinkler Systems

MSC Guidelines for Automatic Sprinkler Systems S. J. Kelly, CDR, Chief of Engineering Division References a. Title 46 CFR 56.20, 56.50 & 56.60 (Subchapter F) b. National Fire Protection Association (NFPA) 13, 1996 Edition, Installation of Sprinkler

More information

The distances in shall be reduced to 130 ft (39.7 m) when manual dry standpipes are installed in open parking garages.

The distances in shall be reduced to 130 ft (39.7 m) when manual dry standpipes are installed in open parking garages. of 123 6/10/2014 9:07 AM First Revision No. 117-NFPA 14-2014 [ Global Input ] 7.3.2.7.5 The distances in 7.3.2.2 shall be reduced to 130 ft (39.7 m) when manual dry standpipes are installed in open parking

More information

40.43 V38, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Low Flow Adjustable Concealed Pendent V3806 QUICK RESPONSE

40.43 V38, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Low Flow Adjustable Concealed Pendent V3806 QUICK RESPONSE SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The V3806 concealed, designer style sprinkler allows up to 1/4"/8 mm adjustment to accommodate concealment needs. The separate two-piece mounting cup/cover plate

More information

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description Worldwide Contacts www.tyco-fire.com Series EC-8 8.0 K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description Pendent Sprinklers are decorative glass bulb sprinklers

More information

freedom residential concealed pendent lead free sprinkler

freedom residential concealed pendent lead free sprinkler Page 1 of 6 Telephone: 269-95-9501 Technical Services: 77--56 Fax: 269-1-0 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Freedom Residential Concealed Pendent Lead Free* Sprinkler VK70 is a small

More information

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016)

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Solvent Extraction Plants

More information

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA Page 1 of 6 1. DESCRIPTION Viking QREC Fusible Element Pendent Sprinkler VK601 is a thermosensitive solder link spray sprinkler available in several different finishes and temperature ratings to meet varying

More information

FREEDOM RESIDENTIAL CONCEALED PENDENT LEAD FREE SPRINKLER VK4570 (K4.9) TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT LEAD FREE SPRINKLER VK4570 (K4.9) TECHNICAL DATA Page 1 of 5 1. DESCRIPTION Viking Freedom Residential Concealed Pendent Lead Free* Sprinkler VK450 is a small high-sensitivity solder link and lever residential sprinkler designed for installation on concealed

More information

Committee Input No. 60-NFPA [ Sections , ]

Committee Input No. 60-NFPA [ Sections , ] Page 1 of 15 Committee Input No. 60-NFPA 34-2013 [ Sections 3.3.7.1, 3.3.7.2 ] Sections 3.3.7.1, 3.3.7.2 3.3.7.1 Combustible Liquid. A Any liquid that has a closed-cup flash point at or above 100 F (37.8

More information

Series LFII Residential Flush Pendent Sprinklers 4.2 K-factor General Description

Series LFII Residential Flush Pendent Sprinklers 4.2 K-factor General Description Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series LFII Residential Flush Pendent Sprinklers 4.2 K-factor General Description The Series LFII (TY2284) Residential Flush Pendent Sprinklers

More information

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA Page 1 of 6 1. DESCRIPTION Viking EC/QREC Pendent Sprinkler VK602 is a small thermosensitive spray sprinkler available in several different finishes and temperature ratings to meet varying design requirements.

More information

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description Worldwide Contacts www.tyco-fire.com Series TY-FRL 5.6 and 8.0 K-factor Extended Horizontal Sidewall s Quick & Standard (Light Hazard) General Description The Series TY-FRL, 5.6, and 8.0 K-factor, Extended

More information

freedom residential concealed pendent Sprinkler vk458 (K7.4)

freedom residential concealed pendent Sprinkler vk458 (K7.4) Sprinkler 142u 1. DESCRIPTION Viking Freedom Residential Concealed Pendent Sprinkler VK458 is a small highsensitivity glass bulb residential sprinkler for use with a domed cover assembly. The orifice design,

More information

Page 1 of 12 Input No. 62-NFPA 409-2013 [ Section No. 3.3.9 ] 3.3.9 Hangar Building Cluster. A group of buildings with more than one area for the storage and servicing of aircraft and all attached or contiguous

More information

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608 Page 1 of 6 TECHNICAL DATA 1. DESCRIPTION The Viking Standard/Quick Response Extended Coverage Light Hazard Extra- Large Orifice (ECLH-ELO/QRECLH-ELO) Pendent Sprinkler VK608 is a thermosensitive spray

More information

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634) January 1, 2011 Sprinkler 92a 1. DESCRIPTION Viking Mirage Quick Response Extended Coverage Concealed Pendent Sprinkler VK632 and VK634 are thermosensitive glass-bulb spray sprinkler designed for installation

More information

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA Page 1 of 6 1. DESCRIPTION Viking Standard/QREC Light Hazard ELO Fusible Element Pendent Sprinkler VK617 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings

More information

Data Sheet 4.24 Issue F

Data Sheet 4.24 Issue F General Description The model RD207 residential flat concealed sprinklers are automatic sprinklers of the compressed fusible solder type. These are decorative and fast response. The cover plate assembly

More information

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

WRENCH FLATS NPT 1/2 7/16 (11,1 mm) NOMINAL MAKE-IN. 1-1/2 (38,1 mm) 2-3/16 (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN. Worldwide Contacts www.tyco-fire.com Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall s Quick and Standard Response (Light Hazard) General Description TYCO Series TY-FRB 5.6 and

More information

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA Page 1 of 5 1. DESCRIPTION Viking QREC Fusible Element Pendent High Pressure Sprinkler VK611 is a thermosensitive solder link spray sprinkler available in several different finishes and temperature ratings

More information

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Pipe and Pipe Fittings. B. Air compressor. C. Air receiver and accessories. D. Aftercooler. E. Refrigerated air dryer. F. Pressure reducing station. 1.02 RELATED

More information

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems General Description The TYCO RAPID RESPONSE Series

More information

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description LFII Residential Horizontal Sidewall

More information

Residential Flat Concealed Sprinkler, Pendent, Model: CN-RES, K-Factor: 4.9, SIN: SS8421

Residential Flat Concealed Sprinkler, Pendent, Model: CN-RES, K-Factor: 4.9, SIN: SS8421 Page:1 of 7 Residential Flat Concealed Sprinkler, Pendent, Model: CN-RES, K-Factor: 4.9, SIN: SS8421 GENERAL DESCRIPTION The Model CN-RES Residential Flat Concealed Sprinklers are automatic sprinklers

More information

microfast sr/qr extended coverage pendent sprinkler

microfast sr/qr extended coverage pendent sprinkler Page 1 of 6 1. DESCRIPTION Viking Microfast EC/QREC Pendent Sprinkler VK600 is a small thermosensitive spray sprinkler available in several different finishes and temperature ratings to meet varying design

More information

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler UL Quick Response FM Standard Response ½ (13mm) Cover plate Adjustment Features 1. Flat cover plate with threaded attachment. 2. Solid or perforated cover plate available in chrome and white as Standard

More information

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

WRENCH FLATS 1/2 NPT. 7/16 (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 4.4 K-factor Horizontal Sidewall Wet Pipe Systems General Description LFII Residential Horizontal Sidewall Sprinklers

More information

40.49 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2744 QUICK RESPONSE

40.49 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2744 QUICK RESPONSE SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The residential sprinkler is designed with optimal flow characteristics for use in residential NFPA 13 systems. The larger 5.6 K-Factor will aid in the system

More information

freedom residential concealed pendent sprinkler VK488 (K3.0)

freedom residential concealed pendent sprinkler VK488 (K3.0) Page 1 of 6 sprinkler VK (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 905 1. DESCRIPTION Viking Freedom Residential Concealed Pendent Sprinkler VK is a small highsensitivity

More information

Page 1 of 7. Replaces Form No. F_ Rev 16.3 (Added 16X22 and 18X20 coverage areas)

Page 1 of 7. Replaces Form No. F_ Rev 16.3 (Added 16X22 and 18X20 coverage areas) Page 1 of 7 1. DESCRIPTION Viking Freedom Residential Concealed Horizontal Sidewall Sprinkler VK490 is a small high-sensitivity solder link and lever residential sprinkler designed for installation on

More information

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems General Description The TYCO RAPID RESPONSE Series

More information

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar). Page 1 of 6 1. DESCRIPTION Viking Mirage Quick Response Extended Coverage Concealed Pendent Sprinkler VK632 and VK634 are thermosensitive glass-bulb spray sprinkler designed for installation on concealed

More information

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM 1 of 213 10/20/2016 11:02 AM Committee Input No. 2505-NFPA 72-2016 [ Global Input ] Change the term visible to visual where appropriate Submitter Information Verification Submitter Full Name: SIG-NAS Organization:

More information

MODEL V-BB SPECIFIC APPLICATION TECHNICAL DATA

MODEL V-BB SPECIFIC APPLICATION TECHNICAL DATA Page 1 of 15 1. DESCRIPTION The Model V-BB (Back to Back) is a Specific Application Attic Sprinkler designed to provide superior fire protection in combustible and non-combustible sloped attic spaces when

More information

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

Model/Sprinkler Identification Number JULY, 2011 WARNINGS Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series EC-11 & EC-14 11.2 and 14.0 K-factor Extended Coverage (Light and Ordinary Hazard) Upright, Pendent, and Recessed Pendent Sprinklers

More information

Location of Requirements Listed Category I appliances Type B gas vent 12.7 Listed appliances equipped with. Chimney Single wall metal pipe 12.

Location of Requirements Listed Category I appliances Type B gas vent 12.7 Listed appliances equipped with. Chimney Single wall metal pipe 12. 2/18/2016 National Fire Protection Association Report Committee Input No. 70 NFPA 54 2015 [ Section No. 12.5 ] This was a First Revision that failed ballot. 12.5 Type of Venting System to Be Used. 12.5.1

More information

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM of 25 7/30/2015 1:35 PM First Revision No. 49-NFPA 17A-2015 [ Detail ] Make the following change to 5.2.1.10.2: 5.2.1.10.2* The manual actuation device shall clearly identify the hazard protected and provide

More information