Vertical V*B Series Fan Coil Technical Catalog Vertical Hideaway (VCB) 200 CFM to 1200 CFM The Vertical Hideaway (VCB) fan coil unit is designed for concealed applications. The coil section is lined with glass fiber insulation to provide positive protection against sweating and maximum dampening of air noise. Standard VCB units are provided with a galvanized finish. Vertical Cabinet (VFB) 200 CFM to 1200 CFM The Vertical Cabinet (VFB) fan coil unit is designed for exposed applications against a wall. The cabinet is fabricated of heavy gauge steel, painted with an attractive powdercoat (arctic white) paint finish. The top panel provides structural rigidity and ruggedness, essential for an exposed unit. VFB units have a removable, one-piece front panel for easy access to all internal components. Vertical V*B Series Fan Coil Units 200-1200 CFM pediair (PA) offers a variety of Vertical Models to meet your Fan Coil Application needs for installations in motels, condos, hospitals, offices and other multi-room buildings. Select from three models: furred-in, flat or sloped top cabinets. Standard and high capacity Hydronic coils are available to match the space heating and cooling loads. Controls are available for numerous system types: 2-pipe heating and cooling, 2-pipe with auxiliary or total electric heat, and -pipe heating/ cooling applications. Design flexibility can be met with numerous options: custom cabinetry for renovation jobs where special sizes are required, solid back panel when units are visible from outside, various insulation materials and filter types, a wide variety of factory preassembled valve packages and unit or remote mounted thermostats to meet desired control specifications. This catalog provides limited unit selection information. For more detailed selections capability, contact your local PA distributor. Vertical Sloped Top Cabinet (VSB) 200 CFM to 1200 CFM The Vertical Sloped Top Cabinet (VSB) fan coil unit is designed for applications where it is necessary to prevent books and other items from being placed on the top of the unit. The cabinet is fabricated of heavy gauge steel, painted with an attractive powder-coat (arctic white) paint finish. The top panel provides structural rigidity and ruggedness, essential for an exposed unit. VFB units have a removable, onepiece front panel for easy access to all internal components.
Table of Contents Cover Basic Unit Descriptions 2 Table of Contents 3 Unit Options and Features - Ratings and Listings 6 Electric Resistance Heating 7 Motor Data 8- Physical Data: VCB Vertical Hideaway 10-11 Physical Data: VFB Vertical Cabinet 12-13 Physical Data: VSB Vertical Sloped Top Cabinet 1 Physical Data: Coil Connection Locations 1-16 Options and Accessories 17-18 Control Packages 1 Piping Packages (Typical) PA works continually to improve its products. As a result, the design and specifications of each product may be changed without notice and may not be as described herein. Please contact PA for information regarding current design and product specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties but are merely PA s opinion or commendation of its products. Manufacturer s standard limited warranty applies. 2 www.xpediair.com xpediair Vertical Series Fan Coils VCB, VFB, VSB
Unit Options and Features Nominal Sizes Vertical Series 02-200 CFM 03-300 CFM 0-00 CFM 06-600 CFM 08-800 CFM 10-1000 CFM 12-1200 CFM Coil Options Two-pipe Applications: Cool Only, Heat Only, Cooling and Heating: 3 Row or Row Four-pipe Cooling and Heating: 3/1 Rows, 3/2 Rows, /1 Rows Coil Connections: Left or Right Hand 1 Same end (-pipe) Opposite end (-pipe) Electric Heat Voltage: 120 V 208 V 20 V 277 V 220 V 2 Sizes (kw): 3 1.00 1.0 2.00 3.00.00.00 6.00 Stages: Single-Stage Only Motors Voltage: 11-1-60 208-1-60 230-1-60 277-1-60 220-1-0 2 20-1-0 2 Type: Permanent Split Capacitor (PSC) ECM (A, B, C) 3-Speed w/off Air Flow Arrangement Front Return Top Supply Front Return Front Supply Controls Voltage: 120 V 208 V 20 V 277 V 2 V System/Application: Manual Fan Operation: Unit-Mounted (Switch Only) VFB, VSB (Standard) VCB (Optional) Wall-Mounted (Switch Only) VCB (Standard), VFB, VSB (Optional) Valve Cycle Control: 2-Pipe Heat Only 2-Pipe Cool Only 2-Pipe Heat and Cool, MCO 2-Pipe Heat and Cool, ACO 2-Pipe Heat and Cool w/auxiliary Electric Heat, MCO 2-Pipe Heat and Cool w/auxiliary Electric Heat, ACO 2-Pipe Cool w/total Electric Heat, MCO 2-Pipe Cool w/total Electric Heat, ACO -Pipe Heat and Cool, MCO -Pipe Heat and Cool, ACO Controls Cont d. Thermostat: Unit-Mounted 16 Series 6 Wall-Mounted Series 1 2 V Programmable 2 V Non-Programmable Service Switch: 11V, 277V, 208V, 230V Single Pole. NOTES: 1. Standing in front of the unit, hand is determined by looking into the air supply and assigning the hand to match the location of the cooling coil connections. 2. Consult factory for 0 Hz applications. 3. KW s are unit size and voltage dependent.. For Front Supply option with unit mounted controls, front-facing controls will be provided.. Furnish only. 6. MCO controls not available with standard unit mount thermostats xpediair Vertical Series Fan Coils VCB, VFB, VSB www.xpediair.com 3
Ratings and Listings C-ETL-US Listing PA s Vertical Series units are listed by ETL. The ETL listing signifies that the factory s fan coil units have been examined by ITS and are in compliance with both the U.S. and Canadian applicable standards. Nominal Cooling Capacity 3061627 HEATING AND COOLING EQUIPMENT Unit Type VCB VFB VSB 02 Unit Size/Coil CFM Cooling Capacity Total MBH Sensible MBH Power input Watts PSC 200 6..7 80 03 300 8.1. 110 0 00 11.6 8.8 13 06 3-Row 600 18.7 13. 10 08 800 20.8 1. 200 10 1000 31.7 21.1 27 12 1200 3.1 23. 3 03 300.2 6. 110 0 00 12.7.1 13 06 600 20.6 1.2 10 -Row 08 800 21.7 1.3 200 10 1000 30.7 1. 27 12 1200 38. 2.6 30 Notes: 1. Ratings are based on 80 F DB and 67 F WB EAT, F EWT, 10 F water temperature rise, high fan speed, motor voltage 11-1-60, and air flow under dry coil conditions. 2. For additional application ratings, use PA s computer selection program or contact your local PA distributor. www.xpediair.com xpediair Vertical Series Fan Coils VCB, VFB, VSB
Ratings and Listings Cont d. Air Performance (60Hz) Model Coil Unit Size VCB VFB VSB 3-Row -Row CFM @ 0.0 ESP For Fan Speed High Speed CFM @ ESP Indicated Low Med High 0.0 0.10 0.1 0.20 02 17 208 2 222 201 180 1 03 22 262 317 300 283 266 28 0 27 30 87 61 3 07 37 06 383 3 62 8 68 3 11 08 377 603 68 6 600 10 10 0 723 71 23 87 823 772 12 738 102 1166 111 1070 1020 68 03 213 26 310 22 27 2 236 0 266 3 63 3 1 38 363 06 373 36 611 82 27 01 08 36 7 66 620 7 30 8 10 7 60 86 88 811 762 711 12 718 7 10 102 100 63 1 NOTES: 1. Tabled values are standard CFM at sea level, 70 F with dry coil. 2. Ratings include factory-installed filter and/or grille, where applicable. 3. Consult factory for 0 Hz applications xpediair Vertical Series Fan Coils VCB, VFB, VSB www.xpediair.com
Electric Resistance Heating Electric heaters are available on PA Vertical Series fan coil units for the following applications. Total Electric Heat Total electric heat eliminates the requirement for a boiler. Heating and/or cooling may be available on an individual basis throughout the year. Two-pipe chilled water is used for cooling, and the electric heater is used for heating. Individual room controls can be supplied for either manual or automatic changeover. Auxiliary Electric Heat Auxiliary electric heat is ideal for tempering room air between seasons and during the cooling season when chilled water is being circulated. Individual room controls are supplied to provide electric heat only when chilled water is being circulated. During the regular heating season, heating is provided by hot water being circulated in the system. Construction Electric Heater Selection Voltage 120V 208V 20V 220/20V 0Hz 277V kw Unit Size 02 03 0 06 08 10 12 1.0 - - - 1. - - - - 2.0 - - - - 3.0 - - - 1.0 - - - 1. - - - - 2.0 - - - - 3.0 - - -.0 - - - - 1.0 - - - 1. - - - - 2.0 - - - - 3.0 - - -.0 - - - -.0 - - - - - 6.0 - - - - - - Notes: 1. All heaters are single stage and single phase. 2. Electric heater available with top or front discharge. 3. Electric Heating Capacities (BTUH) = Heater kw x 313.. Electric Heater Amperage = (Heater kw x 1000)/Applied Voltage. The heater coils of high-grade resistance wire are supported by ceramic insulators on plated steel brackets. These heat elements are suspended directly in front of the fan outlet between the blower and the coil. High limit thermal cutouts protect the heater in the event of air failure. There are many special applications and control sequences for electric heat. For special applications, please consult the factory. 6 www.xpediair.com xpediair Vertical Series Fan Coils VCB, VFB, VSB
Motor Data Thermal Overload Protection All split-capacitor motors furnished by PA contain internal thermal-overload protection. The overload automatically resets when the temperature returns to a safe limit. Electronics Testing Laboratories approves the motor and thermal overload combination at locked rotor conditions only. Motor Performance Data VCB, VFB, VSB Voltage 11 V 60 Hz 1-Phase 208 V 60 Hz 1-Phase 230 V 60 Hz 1-Phase 277 V 60 Hz 1-Phase Fan Speed High Medium Low High Medium Low High Medium Low High Medium Low NOTES: 1. Total unit motor Amps and Watts are shown. 2. Consult factory for 0 Hz applications. Unit Size 02 03 0 06 08 10 12 Nominal HP 1/0 1/30 1/12 1/6 1/6 (2)-1/12 (2)-1/6 Amps 0.3 0.6 1.20 1. 1.2 2. 3.7 Watts 60 80 12 180 1 260 33 Amps 0.3 0.1 0.73 1.30 1.3 1. 2.3 Watts 0 60 8 10 10 17 2 Amps 0.28 0.2 0.6 0.76 0.72 1.18 1.7 Watts 0 60 8 80 13 160 Amps 0.26 0. 0. 0.7 0.7 1.06 1.36 Watts 70 11 1 1 22 270 Amps 0.2 0.3 0.1 0.1 0.2 0.81 0.7 Watts 6 70 8 100 100 17 10 Amps 0.22 0.2 0.26 0.31 0.30 0.1 0.62 Watts 60 0 60 110 120 Amps 0.28 0.7 0.6 0.72 0.80 1.10 1.37 Watts 7 110 130 160 170 260 2 Amps 0.26 0.36 0.3 0.1 0. 0.8 0.7 Watts 70 8 100 11 11 200 210 Amps 0.2 0.2 0.28 0.33 0.33 0. 0.66 Watts 6 60 60 70 6 130 10 Amps 0.16 0.2 0.7 0.68 0.7 1.1 1.37 Watts 70 10 130 18 1 27 2 Amps 0.13 0.37 0.1 0. 0.3 0.80 0.1 Watts 60 8 10 13 13 21 20 Amps 0.10 0.21 0.2 0.1 0.3 0.7 0.7 Watts 6 110 110 10 21 xpediair Vertical Series Fan Coils VCB, VFB, VSB www.xpediair.com 7
Physical Data VCB Vertical Hideaway -1/2 (10) STD. 3-3/ () * D 3-3/ () * 6-1/2 (16) SUPPLY OPENING OPTIONAL CONTROL BO SHOWN (STD IS 2 J-BO) TOP VIEW PLASTIC AUILIARY 77 DRAIN PAN WITH 3/" (1) MPT CONNECTION 2 (63) 1/2" (13) MOUNTING HOLES (TYP OF ) -1/ (23) REMOVABLE FRONT ACCESS PANEL A 1" (2) SUPPLY DUCT COLLAR 2 (1) (DIMENSION FROM MOUNTING HOLE) SUPPLY & WATER RETURN CONNECTIONS 2-1/ (7) VENT (127) SUPPLY 2 (1) SEE TECHNICAL CATALOG FOR DIMENSIONAL DETAILS 11-3/ (28) 1/2(2) (13) RETURN OPENING B C DRAIN TROUGH 2-1/2 (6) (DIMENSION FROM INSIDE CASE LEG) 1" (2) FILTER 2-7/8 (73) RETURN 1 (2) 8-1/ (210) 1/ (23) 16-1/8 (10) 1-1/2 (368) -1/2 (11) MOUNTING HOLES RIGHT SIDE VIEW Unit Model Dimensions Inches (Millimeters) Quantity/Unit Unit A B C D Blower Motor Weight* VCB02 2-3/16 (61) 22 () 23 (8) 16 (06) 1 1 2 VCB03 2-3/16 (61) 22 () 23 (8) 18 (7) 1 1 7 VCB0 3-3/16 (868) 32 (813) 33 (838) 26 (660) 2 1 7 VCB06-3/16 (1122) 2 (1067) 3 36 (1) 2 1 77 VCB08 6-3/16 (1173) (1118) (113) 38 (6) 2 1 7 VCB10 60-3/16 (12) 8 (173) (1) 2 (1321) 2 108 VCB12 68-3/16 (1732) 66 (1676) 67 (1702) 60 (12) 2 127 NOTES: * Unit weights (shown in pounds) are based on dry coils, minimum rows and exclude packaging, valves or other components. 1. Any modifications to product specifications by any person are subject to acceptance of the PA Home Office. Product specifications are subject to change without notice. 2. All dimensions are +/-1/ (6). 3. RH shown, LH opposite. Drawing is provided for reference only. Dimensions may vary with options ordered. Consult PA for submittal drawings. 8 www.xpediair.com xpediair Vertical Series Fan Coils VCB, VFB, VSB
Physical Data Cont d. VCB Vertical Hideaway with Electric Heat -1/2 (10) STD. 3-3/ () * D 3-3/ () * 6-1/2 (16) SUPPLY OPENING OPTIONAL CONTROL BO SHOWN (STD IS 2 J-BO) TOP VIEW PLASTIC AUILIARY 77 DRAIN PAN WITH 3/" (1) MPT CONNECTION 2 (63) STRIP HEATER HIGH LIMIT 1/2" (13) MOUNTING HOLES (TYP OF ) -1/ (23) REMOVABLE FRONT ACCESS PANEL A 1" (2) SUPPLY DUCT COLLAR 2 (1) (DIMENSION FROM MOUNTING HOLE) SUPPLY & RETURN WATER CONNECTIONS 2-1/ (7) VENT (127) SUPPLY 2 (1) SEE TECHNICAL CATALOG FOR DIMENSIONAL DETAILS ELECTRIC STRIP HEATER ELEMENT 11-3/ (28) 1/2(2) (13) RETURN OPENING B C MOUNTING HOLES FRONT VIEW DRAIN TROUGH 2-1/2 (6) (DIMENSION FROM INSIDE CASE LEG) 1" (2) FILTER 2-7/8 (73) RETURN 1 (2) 8-1/ (210) 1/ (23) RIGHT SIDE VIEW 16-1/8 (10) 1-1/2 (368) -1/2 (11) Unit Model Dimensions Inches (Millimeters) Quantity/Unit Unit A B C D Blower Motor Weight* VCB02 2-3/16 (61) 22 () 23 (8) 16 (06) 1 1 2 VCB03 2-3/16 (61) 22 () 23 (8) 18 (7) 1 1 7 VCB0 3-3/16 (868) 32 (813) 33 (838) 26 (660) 2 1 7 VCB06-3/16 (1122) 2 (1067) 3 36 (1) 2 1 77 VCB08 6-3/16 (1173) (1118) (113) 38 (6) 2 1 7 VCB10 60-3/16 (12) 8 (173) (1) 2 (1321) 2 108 VCB12 68-3/16 (1732) 66 (1676) 67 (1702) 60 (12) 2 127 NOTES: * Unit weights (shown in pounds) are based on dry coils, minimum rows and exclude packaging, valves or other components. 1. Any modifications to product specifications by any person are subject to acceptance of the PA Home Office. Product specifications are subject to change without notice. 2. All dimensions are +/-1/ (6). 3. RH shown, LH opposite. Drawing is provided for reference only. Dimensions may vary with options ordered. Consult PA for submittal drawings. xpediair Vertical Series Fan Coils VCB, VFB, VSB www.xpediair.com
Physical Data Cont d. VFB Vertical Cabinet STANDARD STAMPED SUPPLY GRILLE 3-3/ () (127) E D E (127) 3-3/ () CONTROL ACCESS DOOR STD. (2) (OPTIONS AVAILABLE) TOP VIEW -1/ (23) OPTIONAL CONTROL BO SHOWN (STD BO IS 2) REMOVABLE FRONT ACCESS PANEL 2 (1) (DIMENSION FROM MOUNTING HOLE) 1/ TURN PANEL FASTENER TYP. SUPPLY & RETURN WATER CONNECTIONS 1-1/2 (38) VENT -3/ (16) SUPPLY 1-3/ () SEE TECHNICAL CATALOG FOR DIMENSIONAL DETAILS 2 (63) 11-3/ (28) 1/2" (13) MTG. HOLES (TYP. OF ) (22) -1/2 (21) RETURN OPENING C MOUNTING HOLES B A 2-1/2 (6) (22) -1/2 (21) DRAIN TROUGH PLASTIC AUILIARY 77 DRAIN PAN WITH 3/" (1) MPT CONNECTION (DIMENSION FROM INSIDE CASE LEG) 1" (2) FILTER 2-7/8 (73) RETURN 3/ (1) 8-1/ (210) (22) 16-1/8 (10) 1-1/2 (368) -1/2 (11) FRONT VIEW RIGHT SIDE VIEW Unit Model Dimensions Inches (Millimeters) Quantity/Unit Unit A B C D E Blower Motor Weight* VFB02 1 (101) 22 () 23 (8) 17-1/ (38) 3-1/8 (7) 1 1 63 VFB03 1 (101) 22 () 23 (8) 17-1/ (38) 3-1/8 (7) 1 1 68 VFB0 1 (12) 32 (813) 33 (838) 26 (660) 3-3/ () 2 1 82 VFB06 61 (1) 2 (1067) 3 3 (1) 2-1/ (7) 2 1 VFB08 63 (1600) (1118) (113) 3 (1) 3-1/ (83) 2 1 101 VFB10 77 (16) 8 (173) (1) 2-1/8 (132) 3-/8 (2) 2 133 VFB12 8 (21) 66 (1676) 67 (1702) 61 (1) 3-1/ (83) 2 1 NOTES: * Unit weights (shown in pounds) are based on dry coils, minimum rows and exclude packaging, valves or other components. 1. Any modifications to product specifications by any person are subject to acceptance of the PA Home Office. Product specifications are subject to change without notice. 2. All dimensions are +/-1/ (6). 3. RH shown, LH opposite. Drawing is provided for reference only. Dimensions may vary with options ordered. Consult PA for submittal drawings. 10 www.xpediair.com xpediair Vertical Series Fan Coils VCB, VFB, VSB
Physical Data Cont d. VFB Vertical Cabinet with Electric Heat STANDARD STAMPED SUPPLY GRILLE CONTROL ACCESS DOOR STD. (2) (OPTIONS AVAILABLE) OPTIONAL CONTROL BO SHOWN (STD BO IS 2) 2 (63) 3-3/ () -1/ (23) 11-3/ (28) 1/2" (13) MTG. HOLES (TYP. OF ) (127) STRIP HEATER HIGH LIMIT (22) -1/2 (21) E D TOP VIEW RETURN OPENING C MOUNTING HOLES B A REMOVABLE FRONT ACCESS PANEL E 2 (1) (127) (DIMENSION FROM MOUNTING HOLE) 2-1/2 (6) (22) -1/2 (21) 3-3/ () 1/ TURN PANEL FASTENER TYP. SUPPLY & RETURN WATER CONNECTIONS DRAIN TROUGH PLASTIC AUILIARY 77 DRAIN PAN WITH 3/" (1) MPT CONNECTION (DIMENSION FROM INSIDE CASE LEG) 1-1/2 (38) VENT 2-7/8 (73) RETURN 3/ (1) -3/ (16) SUPPLY 8-1/ (210) (22) 1-3/ () SEE TECHNICAL CATALOG FOR DIMENSIONAL DETAILS ELECTRIC STRIP HEATER ELEMENT 16-1/8 1" (2) (10) FILTER 1-1/2 (368) -1/2 (11) FRONT VIEW RIGHT SIDE VIEW Unit Model Dimensions Inches (Millimeters) Quantity/Unit Unit A B C D E Blower Motor Weight* VFB02 1 (101) 22 () 23 (8) 17-1/ (38) 3-1/8 (7) 1 1 63 VFB03 1 (101) 22 () 23 (8) 17-1/ (38) 3-1/8 (7) 1 1 68 VFB0 1 (12) 32 (813) 33 (838) 26 (660) 3-3/ () 2 1 82 VFB06 61 (1) 2 (1067) 3 3 (1) 2-1/ (7) 2 1 VFB08 63 (1600) (1118) (113) 3 (1) 3-1/ (83) 2 1 101 VFB10 77 (16) 8 (173) (1) 2-1/8 (132) 3-/8 (2) 2 133 VFB12 8 (21) 66 (1676) 67 (1702) 61 (1) 3-1/ (83) 2 1 NOTES: * Unit weights (shown in pounds) are based on dry coils, minimum rows and exclude packaging, valves or other components. 1. Any modifications to product specifications by any person are subject to acceptance of the PA Home Office. Product specifications are subject to change without notice. 2. All dimensions are +/-1/ (6). 3. RH shown, LH opposite. Drawing is provided for reference only. Dimensions may vary with options ordered. Consult PA for submittal drawings. xpediair Vertical Series Fan Coils VCB, VFB, VSB www.xpediair.com 11
Physical Data Cont d. VSB Vertical Sloped Top Cabinet STANDARD STAMPED SUPPLY GRILLE CONTROL ACCESS DOOR STD. (2) (OPTIONS AVAILABLE) 3-3/ () (127) E D E (127) 3-3/ () TOP VIEW OPTIONAL CONTROL BO SHOWN (STD BO IS 2) A REMOVABLE FRONT ACCESS PANEL 2 (1) (DIMENSION FROM MOUNTING HOLE) 1/ TURN PANEL FASTENER TYP. 1-1/2 (38) -3/ (16) SUPPLY 1-3/ () 13 (330) 28-3/ (730) 11-3/ (28) 1/2" (13) MTG. HOLES (TYP. OF ) (22) -1/2 (21) RETURN OPENING C MOUNTING HOLES B 2-1/2 (6) (22) -1/2 (21) SUPPLY & RETURN WATER CONNECTIONS DRAIN TROUGH (DIMENSION FROM INSIDE CASE LEG) PLASTIC AUILIARY 77 DRAIN PAN WITH 3/" (1) MPT CONNECTION VENT RETURN 1" (2) FILTER 2-7/8 (73) 3/ (1) 8-1/ (210) (22) SEE TECHNICAL CATALOG FOR DIMENSIONAL DETAILS 16-1/8 (10) 1-1/2 (368) -1/2 (11) FRONT VIEW RIGHT SIDE VIEW Unit Model Dimensions Inches (Millimeters) Quantity/Unit Unit A B C D E Blower Motor Weight* VSB02 1 (101) 22 () 23 (8) 17-1/ (38) 3-1/8 (7) 1 1 6 VSB03 1 (101) 22 () 23 (8) 17-1/ (38) 3-1/8 (7) 1 1 6 VSB0 1 (12) 32 (813) 33 (838) 26 (660) 3-3/ () 2 1 83 VSB06 61 (1) 2 (1067) 3 3 (1) 2-1/ (7) 2 1 100 VSB08 63 (1600) (1118) (113) 3 (1) 3-1/ (83) 2 1 102 VSB10 77 (16) 8 (173) (1) 2-1/8 (132) 3-/8 (2) 2 13 VSB12 8 (21) 66 (1676) 67 (1702) 61 (1) 3-1/ (83) 2 16 NOTES: * Unit weights (shown in pounds) are based on dry coils, minimum rows and exclude packaging, valves or other components. 1. Any modifications to product specifications by any person are subject to acceptance of the PA Home Office. Product specifications are subject to change without notice. 2. All dimensions are +/-1/ (6). 3. RH shown, LH opposite Drawing is provided for reference only. Dimensions may vary with options ordered. Consult PA for submittal drawings. 12 www.xpediair.com xpediair Vertical Series Fan Coils VCB, VFB, VSB
Physical Data Cont d. VSB Vertical Sloped Top Cabinet with Electric Heat STANDARD STAMPED SUPPLY GRILLE CONTROL ACCESS DOOR STD. (2) (OPTIONS AVAILABLE) 3-3/ () OPTIONAL CONTROL BO SHOWN (STD BO IS 2) 13 (330) 28-3/ (730) 11-3/ (28) 1/2" (13) MTG. HOLES (TYP. OF ) STRIP HEATER HIGH LIMIT (127) E D E (22) -1/2 (21) A TOP VIEW RETURN OPENING C MOUNTING HOLES B FRONT VIEW REMOVABLE FRONT ACCESS PANEL (127) (22) -1/2 (21) 3-3/ () 2 (1) (DIMENSION FROM MOUNTING HOLE) 1/ TURN PANEL FASTENER TYP. 2-1/2 (6) SUPPLY & RETURN WATER CONNECTIONS DRAIN TROUGH (DIMENSION FROM INSIDE CASE LEG) PLASTIC AUILIARY 77 DRAIN PAN WITH 3/" (1) MPT CONNECTION 1-1/2 (38) VENT 1" (2) FILTER 2-7/8 (73) RETURN 3/ (1) -3/ (16) SUPPLY 8-1/ (210) (22) 1-3/ () RIGHT SIDE VIEW SEE TECHNICAL CATALOG FOR DIMENSIONAL DETAILS ELECTRIC STRIP HEATER ELEMENT 16-1/8 (10) 1-1/2 (368) -1/2 (11) Unit Model Dimensions Inches (Millimeters) Quantity/Unit Unit A B C D E Blower Motor Weight* VSB02 1 (101) 22 () 23 (8) 17-1/ (38) 3-1/8 (7) 1 1 6 VSB03 1 (101) 22 () 23 (8) 17-1/ (38) 3-1/8 (7) 1 1 6 VSB0 1 (12) 32 (813) 33 (838) 26 (660) 3-3/ () 2 1 83 VSB06 61 (1) 2 (1067) 3 3 (1) 2-1/ (7) 2 1 100 VSB08 63 (1600) (1118) (113) 3 (1) 3-1/ (83) 2 1 102 VSB10 77 (16) 8 (173) (1) 2-1/8 (132) 3-/8 (2) 2 13 VSB12 8 (21) 66 (1676) 67 (1702) 61 (1) 3-1/ (83) 2 16 NOTES: * Unit weights (shown in pounds) are based on dry coils, minimum rows and exclude packaging, valves or other components. 1. Any modifications to product specifications by any person are subject to acceptance of the PA Home Office. Product specifications are subject to change without notice. 2. All dimensions are +/-1/ (6). 3. RH shown, LH opposite Drawing is provided for reference only. Dimensions may vary with options ordered. Consult PA for submittal drawings. xpediair Vertical Series Fan Coils VCB, VFB, VSB www.xpediair.com 13
Physical Data Cont d. All V*B Units J G H F VENT VENT J H G F 16-1/8 (10) 1-1/2 (368) 16-1/8 (10) 1-1/2 (368) LEFT SIDE VIEW RIGHT SIDE VIEW Unit Model 02 03 0 06 08 10 12 Dimensions Inches (Millimeters) Left Side Dimension 1 Row Heat w/3 Row 1 Row Heat w/ Row 2 Row Heat w/3 Row 3 Rows Rows Cool Cool Cool H F H F G J G J G J Sup Ret Sup Ret Sup Ret Sup Ret Sup Ret -1/2-1/2-1/2 6-1/ -1/2 7-1/2-3/ 6-1/ (127) 6 (12) (11) (11) (11) (1) (10) (11) (16) (1) -3/ -1/ -1/ 6-1/ -1/2 7-1/ 7-1/ 6-3/ 6 (12) 7 (178) (121) (133) (108) (1) (10) (18) (18) (171) -1/8-1/2-3/ -1/ 7-1/2 7-1/ 7-1/ 6-1/2 7-1/ -3/ (10) (10) (16) (133) (11) (18) (18) (16) (18) (16) -1/ 6-1/ 6-3/8 7-1/ 7-1/ 7-1/8 7-1/ (127) 6 (12) 7 (178) (133) (1) (12) (18) (18) (181) (18) -1/ 6-1/ 6-3/8 7-1/ 7-1/ 7-1/8 7-1/ (127) 6 (12) 7 (178) (133) (1) (12) (18) (18) (181) (18) -3/ -1/ -3/ -1/ 7-1/ 7-1/2 7-3/8 7-1/2 7-1/ 7-1/2 (16) (133) (16) (133) (18) (11) (187) (11) (18) (11) -3/ -1/2-3/ -1/ 6-1/2 6-1/2 7-1/ 7-1/2 7-1/ 7-1/2 (121) (11) (16) (133) (16) (16) (18) (11) (18) (11) Quantity/ Unit* Blwr Mtr 1 1 1 1 2 1 2 1 2 1 2 2 Unit Model 02 03 0 06 08 10 12 Dimensions Inches (Millimeters) Right Side Dimension 1 Row Heat w/3 Row 1 Row Heat w/ Row 2 Row Heat w/3 Row 3 Rows Rows Cool Cool Cool H F H F G J G J G J Sup Ret Sup Ret Sup Ret Sup Ret Sup Ret -1/ -1/ -1/2-7/8 7-3/ -3/ -1/2 6-3/ -3/ -3/ (108) (108) (11) (12) (17) (16) (10) (171) (16) (16) -1/2-1/ 6-1/ -3/ 6-1/ 7-1/2 7-1/2 6-3/ 6 (12) 7 (178) (10) (108) (1) (121) (1) (11) (11) (171) -3/ -1/2-3/ -1/ 6-1/2 6-3/ -3/ 7 (178) 6 (12) 7 (178) (121) (11) (16) (133) (16) (171) (16) -3/8-1/ -1/2-1/8 6-1/ 7-1/8 6-1/ 7-1/ 6 (12) 7 (178) (111) (108) (10) (130) (1) (181) (1) (18) -3/8-1/ -1/2-1/8 6-1/ 7-1/8 6-1/ 7-1/ 6 (12) 7 (178) (111) (108) (10) (130) (1) (181) (1) (18) -3/ -1/2-3/ -1/2 7-1/ 7-1/2 7-1/2 7-1/2 7-1/ 7-1/2 (16) (10) (16) (10) (18) (11) (11) (11) (18) (11) 6-1/ -1/ -1/2-1/ 6-1/ 6-1/2 7-1/ 7-1/ 7-1/ 7 (178) (1) (133) (10) (133) (1) (16) (18) (18) (18) Quantity/ Unit* Blwr Mtr 1 1 1 1 2 1 2 1 2 1 2 2 NOTES: 1. All dimensions are +/-1/ (6). 2. Product Specifications are subject to change without notice. 3. Same end dimensions shown. Consult factory for opposite end applications. 1 www.xpediair.com xpediair Vertical Series Fan Coils VCB, VFB, VSB
Options and Accessories Features and Options Standard Factory Field Installed Factory Special Air Flow Arrangements Front Return/Top Supply (VCB, VSB, VFB) Front Return/Front Supply (VCB, VFB, VSB) Coils 3-Rows, -Rows, 2-Pipe (VFB, VSB, VCB) 3/1, 3/2, or /1-Rows, -pipe (VFB, VSB, VCB) Manual Air Vent Automatic Air Vent Connection Right or Left (Same End Standard, Opposite End Optional) Drain Pan Painted, Galvanized Externally Coated with a 2-part Closed Cell Foam Stainless Steel Externally Coated Plastic Auxiliary Drain Pan Fin Material Aluminum w/galvanized End Sheets Copper w/stainless End Sheets & Bottom Coil Baffle Nichrome Wire Strip Electric Heater (Total and Auxiliary) Filters 1 Throwaway Non-Woven Synthetic 1 Permanent 1 MERV 8 Pleated 1 MERV 13 Pleated 2 MERV 8 Pleated 2 MERV 13 Pleated Insulation 1/2 Standard Fiberglass 1/2 Premium IAQ Fiberglass 1/2 Foil Face 1/ Closed Cell Motor Type PSC Motors w/quick Connect Plug (V*B) Constant Torque ECM Motors (V*B) Motor Voltage 11/1/60 3-Speed 208/230/277/1/60, 220/1/0 3-Speed Supply/Return Air Grilles Stamped Supply Grille (VFB, VSB) Double Deflection Integral Supply Grille, Painted (VFB, VSB) Double Deflection Aluminum Supply Grille (VFB, VSB) Double Deflection Stainless Steel Supply Grille (VFB, VSB) Stamped Return Grille (VFB, VSB) xpediair Vertical Series Fan Coils VCB, VFB, VSB www.xpediair.com 1
Options and Accessories Cont d. Features and Options Standard Factory Field Installed Factory Special Controls Service Switch with Lockout Tabs Single Point Power Connection Incoming Power Fusing 2 V Controls Condensate Overflow Switch Three Speed Switch Thermostats Unit Mounted 16 Series Wall Mounted 1 Series Digital Non-Programmable 7-Day Digital Programmable 2 V Proportional 7-Day 2 V Proportional BACnet Tamperproof Locks (Camlock) Access Panels (VFB, VSB) Access Doors (VFB, VSB) Filters All Vertical V*B Series units non-woven, synthetic throwaway filters furnished as standard equipment. Cleanable or MERV 8 or MERV 13 pleated filters are optional. Unit Size Nominal One-Inch Filter Size Inches (Millimeters) VCB, VFB, VSB 02 7-3/ x 21-3/ (17 x 2) 03 7-3/ x 21-3/ (17 x 2) 0 7-3/ x 31-3/ (17 x 806) 06 7-3/ x 1-3/ (17 x 1060) 08 7-3/ x 3-3/ (17 x 1111) 10 7-3/ x 7-3/ (17 x 167) 12 7-3/ x 6-3/ (17 x 1670) NOTE: Sizes shown are nominal ordering sizes. 16 www.xpediair.com xpediair Vertical Series Fan Coils VCB, VFB, VSB
Control Packages Controls: As detailed in the table below, we offer a control for most of our customer s need. Additional controls and devices are available to meet even the most demanding operating logic. Three-speed Fan Control All of our basic control schemes utilize a 3-speed switch to modulate the cooling output, to maximize the percentage of latent heat removal, and to further minimize the sound level when maximum cooling or heating performance is not required. Low Voltage Control (2 V) A low voltage control is available with all of our control schemes. Condensate Overflow Switch This switch shuts down the unit when the water level in the drain pan reaches an unsafe level. Building code changes in much of our country now require this type of device. Service Switches We offer service switches for use by maintenance and service personnel to shut off the power while working on the unit. Fusing We offer incoming power fusing for all units as well as blower motor and control sub-fusing for units that use electric heat. The blower motor and control sub-fusing (single power source wiring) is required when single source power with electric heat is specified. Unit Mounted Series 16 Vertical Wall Series 1 2 V Programmable and Non- Programmable Digital Series 2 V Proportional Unit Type Control Option System Type Code Changeover Type Unit Mounted Series Vertical Wall Series 2 V Programmable and Non- Programmable Digital Series 2 V Proportional Manual Fan Manual A None Heat Only G None Cool Only H None 2-Pipe J Manual Heat/Cool K Automatic Heat/Cool with L Manual Valve Cycle Auxiliary Electric Heat M Automatic Cool with Total N Manual Electric Heat P Automatic -Pipe Heat/Cool Q Manual R Automatic xpediair Vertical Series Fan Coils VCB, VFB, VSB www.xpediair.com 17
Control Packages Cont d. Thermostats Thermostats System Function Mode Control Type* C B F G P N 2-Pipe Heat Only None 2-Pipe Cool Only None 2-Pipe Heat/Cool ACO MCO N/A Basic Control Needs Thermostat Features All listed controls include fan switching. 2-Pipe 2-Pipe -Pipe Heat/Cool with Auxiliary Electric Heat Cool with Total Electric Heat Heat/Cool *Control Type Legend: C Unit Mounted Series 16 B Vertical Wall Series 1 F 2 V Proportional 7-Day G 2 V Proportional BACnet P 2 V Digital Programmable N 2 V Digital Non-Programmable Supply Air Grilles (Optional) Unit Size ACO MCO N/A ACO MCO N/A ACO MCO N/A 2 Volts Programmable N/A N/A N/A N/A Non-Programmable N/A BACnet N/A N/A N/A N/A N/A Remote Wall Mounted N/A 3-Speed Fan Proportional Fan (0-10V) N/A N/A N/A N/A Continuous Fan Cycling Fan N/A N/A N/A Remote Temperature Sensor N/A Opt Opt Adjustable Operating Range Kit Kit Touch Pad/Digital Display N/A N/A N/A Local Temperature Set-Back N/A N/A N/A Water Temperature Purge Cycle N/A N/A N/A Pipe Sensor N/A N/A N/A Nominal CFM Control Options 2 V control packages Single power source wiring (motor/control fusing) Incoming power fusing Service switches Minimum room temperature thermostats (Special Quote) Low voltage remote shutdown relays (Special Quote) Recommended Grille Sizes Inches (Millimeters) VFB, VSB 02 200 16 x 6 (06 x 12) 16 x (06 x 127) 03 300 16 x 6 (06 x 12) 18 x (7 x 127) 0 00 26 x 6 (660 x 12) 26 x (660 x 127) 06 600 36 x 6 (1 x 12) 36 x (1 x 127) 08 800 38 x 6 (6 x 12) 38 x (6 x 127) 10 1000 2 x 6 (1321 x 12) 2 x (1321 x 127) 12 1200 60 x 6 (12 x 12) 60 x (12 x 127) NOTES: 1. Refer to Physical Data for actual unit supply air opening dimensions. 2. VFB and VSB models supply air grilles are factory installed. 3. Consult factory for application restrictions using double-deflection grilles with electric heat and maximum coil rows.. VCB models supply air grilles are shipped loose. VCB 18 www.xpediair.com xpediair Vertical Series Fan Coils VCB, VFB, VSB
Piping Packages (Typical) Two-way Motorized Control Valve In a two-way motorized control valve package, the motor drives the valve open, and a spring returns the valve to a normally closed position. No water flows with the unit off. The standard supply connection from the coil will accept a swaged copper fitting for field soldering. As an option, this connection may be factory furnished with a union. When a swage is necessary, it becomes part of the valve package. The isolation ball valve in the return piping is shipped loose for field installation. Air Vent Coil Swage 2- way Valve Three-way Motorized Control Valve Ball Valve (Shipped Loose) Ball Valve In a three-way motorized control valve package, a diverting valve controls water flow to the coil. When the unit is off, water bypasses the coil and flows directly to the system return. A balancing valve may be specified in the bypass line to permit equal flow balancing. Air Vent Coil Swage 3- way Valve Ball Valve Optional Balance Valve R S R Two-way Motorized Control Valve with Aquastat Bypass Line In a two-way motorized control valve package, the motor drives the valve open, and a spring returns the valve to a normally closed position. No water flows through the coil with the unit off. The aquastat bypass line allows a small amount of water to flow from the supply to the return piping when the control valve is closed. The strapon aquastat senses whether the flowing water is being chilled or heated and switches a contact closed to provide automatic summer/winter changeover (ACO) for the system. When a 2-pipe cooling/heating system with optional auxiliary electric heat is desired, additional components are required. Air Vent Coil Swage Swage 2- way Valve A Aquastat Ball Valve Aquastat Bleed Bypass Line NOTES: 1. Please note that project specifications for system pressure, pressure drop limitations and flow rate should be checked prior to selecting specific components or the valve package size. 2. The supply and return piping connections of the factoryprovided valve package are either swaged for field brazing (standard) or union fitted (optional) for field connection to the coil. 3. Consult PA s Valve Packages and Piping Components manual or your local distributor for detailed piping and valve application information. Factory-provided valve packages are assembled, brazed, wired electrically and dry-fit to the coil connections before shipping. Field brazing to the coil completes the installation. Some applications dictate shipping isolation valves loose. R S Swage A Aquastat Ball Valve S xpediair Vertical Series Fan Coils VCB, VFB, VSB www.xpediair.com 1
Part #: I100-001386 PA CA-270-031 2013 xpediair (PA) a brand name of International Environmental Corporation, a subsidiary of LSB Industries, Inc. NYSE symbol LU; www.lsb-okc.com P.O. Box 28 / OKC, OK 73101-28 / P. 0.60.000 / FA 0.60.001