McQuay. Seasonmaker ThinLine Horizontal Fan Coil. TSH, TSC Vintage F. FTSH, FTSC Designs A(1), B(2) Last Manufactured: 2008
|
|
- Marian Simmons
- 6 years ago
- Views:
Transcription
1 Replacement Parts List No Revision R 12/2017 McQuay Seasonmaker ThinLine Horizontal Fan Coil TSH, TSC Vintage F FTSH, FTSC Designs A(1), B(2) Last Manufactured: 2008 To find your Daikin Applied parts distributor, call or visit
2 Contents About the Model Number Changes... 2 Parts List Revision History... 3, 4 Nomenclature Serial Number... 5 Model Number- TSC, TSH Model Number- FTSC, FTSH until 3/ Model Number- FTSC, FTSH 3/11 & later Unit Assembly Diagram Components Coils Fan Deck Assembly Diagram Components Fan Motor, Capacitor, Motor Mount Cabinet Assembly- TSC/FTSC Diagram Components Electric Heaters- TSC/TSH F Vintage Electric Heater Control Components- TSC/TSH "F" Valves and Air Vent Kits-TSC/TSH "F" Field Installed Accessories- TSC/TSH "F" Units Field Installed Accessories- FTSC/FTSH Units Critical Parts List TSH, TSC... CPL1 FTSH, FTSC... CPL2 About the Model Number Changes In 1999 the model numbering nomenclature for the Horizontal Thinline Fan Coil changed: The TSC "F" Vintage unit is now the FTSC Design "B" unit. The TSH "F" Vintage unit is now the FTSH Design "B" unit. The unit's components did not change when the nomenclature did (a few engineering changes have taken place since this RPL was last issued, and the part number changes are noted). The complete model number nomenclature currently used has been added to this revision. Unless otherwise noted, all components listed in this revision apply to both the current and the original model numbered units. Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 2
3 Parts List Revision History Revision Date Description A 6/98 Updated to On-Line format. Added Revision History page. Page 22- Corrected Circuit Breaker p/n. B 10/99 Page 11 -Updated information for all Motors and Motor Mounts. C 2/00 Page 22 -Automatic Changeover Clip-# & Assembly-# were added. D 7/01 Page 7 - Added Secondary Drain Pan, RH # & LH # , both N/S. E 10/02 Page 11 - Shifted some type that was misaligned / no change to content. F 10/02 Added new model nomenclature for FTSC and FTSH units. All part numbers converted to current McQuay Mitrol format. Page 5 - Added Serial Number Nomenclature for units built after 2/99. Page 6 - Added new. Page 8 - Added foot notes for fan panel (Ref# 20), coils (Ref# 30) and raceway (Ref# 84). Ref# 85 P/N for size 04 changed to Page 9 - Ref# 93 added P/N for units built 9/02 and later. Ref# 98 all P/N changed to "K" version. Page 10 - Reformatted entire page and added Design "B" coils for FTSC and FTSH units. Corrected p/n for TSC & TSH water coils. Added TSC & TSH size 121F steam coil. Pages 11, 12 - Added new. Page 13 - Rearranged diagram and added reference numbers for fan panel and housings for each size grouping. Page 14 - Added notes explaining composition of Fan Deck Assy, application of Standard/ Hi-Static motors and the 230/50/1 motor. Merged complete assemblies and the individual components into one chart. Removed motors from component chart and put them in a separate chart on the following pages, and added note. Page 15 - Removed motor mounts and capacitors for the component chart and put them in a separate chart. Added motor/capacitor/motor mount charts. Pages 16, 17, 18 - Added new. Page 22 - Added notes regarding application of insulated cabinet parts, stamped grille and FTSC return air codes. Ref# 203 P/N for sizes 03/04 & 06/08 changed to & respectively. Ref# 211 P/N for sizes 03/04 duct opening changed to P/N for sizes 06/08 & 10/12 stamped grille panel changed to & Ref# 212 P/N for all variations changed. Page 23 - Ref# 214 P/N for the insulated panel changed to Ref# 215 P/N for insulated panel sizes 03/04, 06/08 & 10/12 changed to , & respectively. P/N for standard panel sizes 03/04 & 10/12 changed to & respectively. Ref# 216 P/N for all variations changed. Page 24 - Note added in heading referencing application of referenced electric heaters. Combined size 101F and 121F heaters from subsequent page. Page 25 - Size 101F and 121F heaters moved to previous page. Added 'Valves and Air vent Kits' from subsequent page (which was removed). P/N for 120V 2-way valve changed to P/N for 120V 3-way valve changed to P/N for 277V 2-way valve changed to P/N for 277V 3-way valve changed to Page 26 - TSC/TSH "F" Field Accessories combined onto one page (removed 1 page) P/N for Types 1,2,3 and 7 3-Speed Switch changed to P/N for Type 2 subbase changed to P/N for Type 5 T-Stat changed to P/N for Trim Flange Kits for sizes 031/041, 061/081 & 101/121 changed to , & respectively. P/N for ACO switch changed to Pages 27 thru 31 Added new. Continued on next page. Daikin Applied, Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN (763) Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 3
4 Parts List Revision History Revision Date Description G 04/05 Page 26 - Added Note ***Thermostat can be used for only one mode at a time. Not a combination (either heating only OR cooling only). H 12/05 Page 9-Added zeros infront of p/n's. Page 14-Bub. #1 Fan Deck Panel 061/081 p/n changed from to Page 25-Valve/Balancing, Valve/Ball T-handle, Valve/Water- Manual; added 2/04 &Later Page 27 - Added Hard Ball Valve for 5/8" Sweat '2/04 and Later to Manual Valve table Page 28 - Footnote #10 re-worded. J 11/08 Page 23 - Note change from SMG Parts Tech to McQuay Parts. Page 24 - Change pn from to for unit size 121F 208V/4 KW. K 9/09 Page 9- Ref#95 Change Qty for p/n size 101F to 0 and for size 121F to 1. Change Qty for p/n size 101F to 0 and for size 121F to 1. L 7/10 Reformat document from PageMaker to CS4. Page 10- Size S03 p/n change from 3 Row to 2 Row. Size S04 p/n change from 3 Row to 2 Row. Page 11- Size S06 p/n change from 3 Row to 4 Row. Size S08 p/n change from 3 Row to 4 Row. Page 12- Size S10 p/n change from 3 Row to 4 Row. Size S12 p/n change from 3 Row to 4 Row. M 4/12 Page 9- Add Secondary Drain Pan LH p/n & RH p/n Page 29- Add Secondary Drain Pans Stainless Steel, LH p/n & RH p/n CPL1- Add Critical Parts List. N 9/13 Numerous changes done. Sheet metal deleted and note added. Delete Plenum diagram and components pgs Pages 6-10 Add new code string- Model Number 6/11 & later. Pages Change capacitor p/ns to , to , to , and to Change motor p/n description from high static to standard on S04 & S10 units. Change mount p/n to on unit 061F/S06 for motor p/n Page 24- Ref# 212 Change standard panel assy p/n to S06/S08. CPL1- Split CPL into two pages. This CPL page is for TSC, TSH units. CPL2- Split CPL into two pages. This CPL page is for FTSC, FTSH units. Change motor p/n description from high static to standard on S04 & S10. O 2/15 Pages 19,20,21 Change capacitor for motor p/n from p/n to CPL1-2 Change CPL Master. P 03/16 Rebrand Daikin. Numerous changes. Page 11- Change switch Bubs 95 & 96. Page 12- Change Ref# 95 Description to Drain Pan Assy aand use DP Assy p/ns. Change Ref# 96 Description to Drain Pan, Outer. Page 14- Change Coil size 06 & 08 p/n to Page 17- Update the chart format. CPL1, CPL2- Rebrand Daikin. Q 08/16 Page 26- Change footnote #15 From "Duct Opening" to "Stamped grille". Change footnote #16 From "Blank (stamped grille) to "Blank panel". CPL1-CPL2 Update revision. R 12/17 Title Page- Add Last Manufactured : Page 19- Change Hub Clamp p/n to CPL1-CPL2 Update revision. Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 4
5 Nomenclature Serial Number (until 2/1999) 7 6A Factory Engineering Revision 7= Auburn, NY 5= Staunton, VA Serial Number Year and Month of Manufacture: Year Month Q= = 1995 A= Jan. G= Jul. R= = 1996 B= Feb. H= Aug. S= = 1997 C= Mar. J= Sep. T= = 1998 D= Apr. K= Oct. U= = 1999 E= May L= Nov. V= 1990 F= Jun. M= Dec. W= 1991 X= 1992 Y= 1993 Z= 1994 Serial Number (2/1999 to present) AUB U Plant Identification Abbreviation AUB = Auburn Serial Number (build sequence) U= Unit Week of Manufacture Year of Manufacture 08= = 2009 etc. Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 5
6 Nomenclature Model Number- TSC, TSH TSC 121F R A A 1 A B 1 A Y A100 YY 01EV 21EV 1 Code Code 01: Unit Type TSC= Seasonmaker, Ceiling Unit TSH= Seasonmaker, Ceiling Hideaway Code 02: Unit Size (in 100's cfm) 031F= 300 cfm 041F= 400 cfm 061F= 600 cfm 081F= 800 cfm 101F= 1000 cfm 121F= 1200 cfm Code 03: Unit Hand R= Right Hand L= Left Hand Code 04: Coil Type A= Standard Coil C= High Capacity Coil Separate 1-Row Htg D= Std. Coil, Opp Hand Conn. F= Hi Cap Coil, Opp Hand Conn. H= Std. Coil, Same Hand Conn. Separate 1-Row Water Htg K= Hi Cap Coil, Same Hand Conn. M= Std. Coil, Opp Hand Conn. Separate 1-Row Steam Htg P= Hi Cap Coil, Opp Hand Conn. Q= Std. Coil, Same Hand Conn. S= Hi Cap Coil, Same Hand Conn. Code 05: Voltage A= 115/60/1 P= 265/60/1 J= 230/50/1 Code 06: Motor Type 1= Standard 2= High Static Code 07: Cabinet Plenum Options A= Standard Cabinet B= Insulated Cabinet C= Factory Installed Plenum w/duct Collar & TA Filter Y= No Plenum or Filter Code 08: Discharge Air Arrangements B= Stamped Grille C= Duct Opening w/o Collar Y= Duct Collar Code 09: Air Return 1= Bottom Stamped Opening 4= Back Duct Opening 5= Both 1 & 4 Code 10: Filter A= Throwaway B= Cleanable Code 11: Always Y Code 12: Electric Heat E 200 YYY Unit Size 031F 041F 061F 081F 101F 121F Voltage Wattage 120V 208V 240V 265V KW Code KW Code KW Code KW Code 1.0 A E K P A E K P E K P A E K P A E K P E K P A E K P E K P E K P A E K P E K P E K P E K P E K P P E K P E K P P800 Continued on next page. Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 6
7 Nomenclature Model Number- TSC, TSH- Continued Code 13: Control System 05= 2 Pipe, Valve Cycle, MCO, TStat & 3-Spd Switch 06= 2 Pipe, Valve Cycle, ACO, TStat & 3-Spd Switch 07= 2 Pipe, Valve Cycle, Htg only, TStat & 3-Spd Switch 08= 2 Pipe, Valve Cycle, Clg only, TStat & 3-Spd Switch 09= 2 Pipe, Valve Cycle, MCO, Comb- TStat & 3-Spd Sw 10= 2 Pipe, Valve Cycle, ACO, Comb- TStat & 3-Spd Sw 11= 2 Pipe, Valve Cycle, Htg only, Comb- TStat & 3-Spd Sw 12= 2 Pipe, Valve Cycle, Clg only, Comb- TStat & 3-Spd Sw 17= 2 Pipe, Fan Cycle, MCO, TStat & 3-Spd Switch 18= 2 Pipe, Fan Cycle, ACO, TStat & 3-Spd Switch 19= 2 Pipe, Fan Cycle, Htg only, TStat & 3-Spd Switch 20= 2 Pipe, Fan Cycle, Clg only, TStat & 3-Spd Switch 21= 2 Pipe, Fan Cycle, MCO, Comb- TStat & 3-Spd Sw 22= 2 Pipe, Fan Cycle, ACO, Comb- TStat & 3-Spd Sw 23= 2 Pipe, Fan Cycle, Htg only, Comb- TStat & 3-Spd Sw 24= 2 Pipe, Fan Cycle, Clg only, Comb- TStat & 3-Spd Sw 27= 2 Pipe, Elect Ht & 2 Pipe Clg, TStat & 3-Spd Sw 30= 2 Pipe, Elect Ht & 2 Pipe Clg, Comb- TStat & 3-Spd Sw 32= 2 Pipe, Elect Ht, Comb- TStat & 3-Spd Sw 35= 4 Pipe, Valve Cycle, DPDT TStat & 3-Spd Sw 37= 4 Pipe, Valve Cycle, Comb- DPDT TStat & 3-Spd Sw 61= 2 Pipe, Int Elec Ht, 2 ACO, DPDT TStat & 3-Spd Sw 62= 2 Pipe, Int Elec Ht, 2 ACO, Comb- DPDT TStat & 3-Spd Sw 71= 2 Pipe, Fan & Valve Cycle, MCO, TStat & 3-Spd Sw 72= 2 Pipe, Fan & Valve Cycle, ACO, TStat & 3-Spd Sw 73= 2 Pipe, Fan & Valve Cycle, Htg only, TStat & 3-Spd Sw 74= 2 Pipe, Fan & Valve Cycle, Clg only, TStat & 3-Spd Sw 75= 2 Pipe, Fan & Valve Cycle, MCO, Comb- TStat & 3-Spd Sw 76= 2 Pipe, Fan & Valve Cycle, ACO, Comb- TStat & 3-Spd Sw 77= 2 Pipe, Fan & Vlv Cycle, Htg only, Comb- TStat & 3-Spd Sw 78= 2 Pipe, Fan & Vlv Cycle, Clg only, Comb- TStat & 3-Spd Sw Y Code 14: Water Cooling Coil Valve Package YYY 01EV= 2-Way Electric Valve, LH 02EV= 3-Way Electric Valve w/o Bypass Bal Valve, LH 03EV= 3-Way Electric Valve w/bypass Bal Valve, LH 11EV= 2-Way Electric Valve, RH 12EV= 3-Way Electric Valve w/o Bypass Bal Valve, RH 12PN= 3-Way Pnuematic, RH 13EV= 3-Way Electric Valve w/bypass Bal Valve, RH Code 15: Water Heating Coil Valve Package YYY 21EV= 2-Way Electric Valve, LH 22EV= 3-Way Electric Valve w/o Bypass Bal Valve, LH 23EV= 3-Way Electric Valve w/bypass Bal Valve, LH 31EV= 2-Way Electric Valve, RH 32EV= 3-Way Electric Valve w/o Bypass Bal Valve, RH 33EV= 3-Way Electric Valve w/bypass Bal Valve, RH Code 16: Disconnect 1= Unit Mntd Disc Switch 2= Circuit Breaker Disc Switch Code 17: Packaging Code 18: Agency Code 19: Miscellaneous Code 20: Always Y Code 21: Warranties Code 22: Always A Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 7
8 Nomenclature Model Number- FTSC, FTSH until 3/11 F TSC 1 S03 A A 70 E 00 AY 18 G I Code Code 01: Unit Type F= Fan Coil Code 02: Product Identifier TSC= Thinline Horizontal Fan Coil TSH= Thinline Horizontal Fan Coil, Hideaway Code 03: Design Series 1= A Design 2= B Design Code 04: Unit Size (in 100's cfm) S02= 200 cfm H02= 200 cfm S03= 300 cfm H03= 300 cfm S04= 400 cfm H04= 400 cfm S06= 600 cfm H06= 600 cfm S08= 800 cfm H08= 800 cfm S10= 1000 cfm H10= 1000 cfm S12= 1200 cfm H12= 1200 cfm Code 05: Voltage A= 115/60/1 J= 265/60/1 Code 06: Coil Otions A= Standard Coil (Not With Steam Heat) H= High Capacity Code 07: Heating Options 00= None 70= 1-Row Heating Coil (HW) 72= 2-Row Heating Coil (Steam) Code 08: Hand Orientation A= Same Hand Left* B= Same Hand Right* E= Left Hand Heat/Right Hand Cooling F= Right Hand Heat/Left Hand Cooling *(valve kits will not fit on these units) Code 09: Controls 00= None Code 10: Discharge AY= Front (FTSC) AX= Top (FTSH) Code 11: Return Air/Outside Air 17= Rear Ducted w/ Filter (FTSH) 18= Bottom Return, Stamped Grille (FTSC) 20= Rear Return Code 12: Power Connection G= Box w/ Switch Z= None Code 13: Color I= Antique Ivory (FTSC) Z= None (FTSH) Code 14: SKU Type Code 15: Style Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 8
9 Nomenclature Model Number- FTSC, FTSH 03/11 & later FT SC 2 S10 A A G M Y YY W412LYS YY00YYY YY W112LYS Y 000 Code YY G PSC S 3 Y YY YY YYY D Y Y Y Y Y YY YYY Y YYYY Code YYYY YYYY Y Y C YYYY YYY S 18 B I 00 S 0000 YYY FS BS Y Code YYY Y 2 Code Code 01 & 02= Unit Type FTSC= Thinline Horizontal Fan Coil FTSH= Thinline Horizontal Fan Coil, Hideaway Code 03= Design Series 1= A Design 2= B Design Code 04= Unit Size (in 100's cfm) S03= 300 cfm H03= 300 cfm S04= 400 cfm H04= 400 cfm S06= 600 cfm H06= 600 cfm S08= 800 cfm H08= 800 cfm S10= 1000 cfm H10= 1000 cfm S12= 1200 cfm H12= 1200 cfm Code 10= Always YY Code 05= Voltage A= 115/60/1 J= 265/277/60/1 Coil Options Code 06= Coils- Fin Type A= Aluminum Code 07= Coils- Casing Material G= Galvanized Code 09= Coils- Coating Code 10= Always YY Primary Coil Code 11 to 16= Primary Coil C 3 12 R Y S Connection Type S= Sweat T= Threaded Piping Package F= Factory Installed Connection Location L= Left Hand R= Right Hand Fins-per-inch 12= 12 FPI Rows 1= 1-Row (Horizontal heaters only) 2= 2-Row 3= 3-Row 4= 4-Row Coil Type C= Chilled Water Only H= Hot Water Only W= CW/HW 2- Pipe S= Steam Code 08= Coils- Air Vent A= Auto M= Manual Continued on the next page. Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 9
10 Nomenclature Model Number- FTSC, FTSH 3/11 & later Continued Preheat Coil Code 17 to 21= Preheat Coil YY 00 Y Y Y Connection Type S= Sweat T= Threaded Code 22= Always YY Piping Package F= Factory Installed Connection Location L= Left Hand R= Right Hand Fins-per-inch 12= FPI 00= None Coil Type E1= Electric Single Stage M1= Intermediate Electric Heat Single Stage W1= 1-Row Water W2= 2-Row Water S1= 1-Row Steam S2= 2-Row Steam Y Reheat Coil Code 23 to 27= Secondary Reheat Coil W Y S Connection Type S= Sweat T= Threaded Piping Package F= Factory Installed L= Ship Loose Connection Location L= Left Hand R= Right Hand Fins-per-inch 12= 12 FPI 00= None Coil Type W1= 1-Row Water (CW) W2= 2-Row Water (CW) S1= 1-Row Steam (CW) Y (CW/HW) Code 28= Electric Heat Power Supply A= 115/60/1 G= 230/60/1 C= 208/60/1 J= 265/60/1 E= 208/230/60/1 L= 230/50/1 Code 29= Electric Heat Wattage 005= 0.5 kw 040= 4.0 kw 010= 1.0 kw 050= 5.0 kw 015= 1.5 kw 060= 6.0 kw 020= 2.0 kw 070= 7.0 kw 025= 2.5 kw 080= 8.0 kw 030= 3.0 kw 100= 10.0 kw 000= None Code 30= Always YY Code 31= Drain Pan Material G= Galvanized P= Plastic S= Stainless Steel Code 32= Blower Motor Type PSC= PSC Motor ECM= DC Motor Type Code 33= Discharge Conditions S= Standard Static H= High Static Code 34= Motor Speed 3= 3 Speed Code 35= Motor Connections Q= Quick Connect Code 36= Always YY Code 37= Fresh Air Damper 1st Digit- Fresh Air Opening Location R= Rear T= Top 2nd Digit- Damper Type M= Manual 2= Auto, 2-Position (Field Install Only) E= Auto, Economizer Code 38= Cabinet Size YYY= Standard Cabinet AYY= Small Cabinet Code 39= Unit Disconnect Switch D= Disconnect Switch- Toggle Continued on the next page. Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 10
11 Nomenclature Model Number- FTSC, FTSH 3/11 & later- Continued Code 40= Site Control Voltage L= 24V (low) Voltage H= Line Voltage Code 41= Control Type D= Digital L= Low Voltage interface Board & 3 Speed Switch P= Analog TStat R= Low Voltage Interface Board S= 3 Speed Switch Code 42= Network Communication Card Code 43= Changeover Type A= Auto Sensor M= Manual S= Auto Switch U= User Selectable Code 44= Programmability C= 7 Days Code 45= Setpoint Adjustment 1st Digit- Location I= Remote Mounted IR R= Remote Mounted Hardwired 2nd Digit- Type F= Full Range L= +/- 5 Degrees Code 46= Fan Speed Control Digit 1: Speed Adjustment Type A= Auto (Staged) M= Manual Digit 2: Available Fan Speeds B= Off/ Low/Med/High D= Off/ Low/High Digit 3: Mounting Location R= Remote (Wall mounted w/mt3) U= Unit Mounted Code 47= Timed Override R= Remote U= Unit Mounted Code 48= Primary Coil Valve Y Y Y Y Actuator Input F= 3 Wire Floating Point L= Low Voltage (24V)- EOC P= 0-10V Proportional- Mod U= Unit Voltage- EOC/Mod Control Type E= EOC M= Modulating Unpowered Position C= Closed O= Open Primary Coil Valve Type 2= Two Way 3= Three Way Code 49= Preheat Coil Valve Y Y Y Y Actuator Input F= 3 Wire Floating Point L= Low Voltage (24V)- EOC P= 0-10V Proportional- Mod U= Unit Voltage- EOC/Mod Control Type E= EOC M= Modulating Unpowered Position C= Closed O= Open Preheat Coil Valve Type 2= Two Way 3= Three Way Code 50= Reheat Coil Valve Y Y Y Y Actuator Input F= 3 Wire Floating Point L= Low Voltage (24V)- EOC P= 0-10V Proportional- Mod U= Unit Voltage- EOC/Mod Control Type E= EOC M= Modulating Unpowered Position C= Closed O= Open Reheat Coil Valve Type 2= Two Way 3= Three Way Continued on the next page. Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 11
12 Nomenclature Model Number- FTSC, FTSH 3/11 & later Continued Code 51= Return Air Thermostat Code 52= Low Temperature Protection A= Auto Code 53= Condensate Overflow Protection C= Condensate Overflow Protection Code 54= Discharge Air Thermistor Code 55= Smoke Input S= Smoke Input Code 56= Occ/Vacant Control Input V= Vacant/Occupied Control Code 57= Filter Status Code 58= Fan Status A=Continuous Fan Operation C= Operation Cycles w/demand Code 59= Entering Water Thermistor E= Entering Water Thermistor Code 60= Always Y Code 61= Cabinet Style S= Standard T= Tamperproof Code 62= Cabinet Guage 16= 16 Guage 18= 18 Guage Y Code 63= Cabinet Coating Type B= Powder Coat Code 64= Cabinet Color B=Putty Beige C= Cupola White G= Soft Gray I= Antique Ivory W= Off White N= None Code 65= Cabinet Depth Extension 04= 4 Inch Extended Depth (Field Installed) 08= 8 Inch Extended Depth (Field Installed) 00= None Code 66= Unit Lineup Position S= Standalone Code 67= Left Hand End Pocket Extension 00= None Code 68= Right Hand End Pocket Extension 00= None Code 69= Subbase Digit 1:Height 35= Standard Subbase (Approx, 3.3") Y Digit 2: Leveling Feet F= Leveling Feet Code 70: Discharge Air- Outlet Digit 1: D/A Location F= Front T= Top Digit 2: Type A= Double Deflection Adjustable Grille D= Duct Collar S= Stamped Louver P= Open Code 71: Return Air Inlet Digit 1: R/A Location B= Bottom F= Front T= Top Digit 2: Type R= Open Return S= Stamped Louver T= Toe Space Code 72: Filter 1= 1" Throwaway MERV 3 2= 1" Throwaway Pleated MERV 8 3= 1" Throwaway + (1) Extra 5= Washable Filter 7= 1" MERV 13 HIgh Efficiency Code 73= Alway YYY Code 74= Cabinet/Plenum Insulation F= Fiberglass 1/2" C= Closed Cell 1/4" Code 75: Agency Listing Code 76: Packaging Code 77: Warranty Code 78: Product Style/Quick Ship Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 12
13 Unit Assembly Diagram Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 13
14 Unit Assembly Components Unit Size Ref Description Part No. Number 80 Plate- Base Plate- Left Hand Plate- Right Hand Plate- Top Raceway- Electrical Wire Access Panel- Bottom Seal Strip- Adh. Back Seal Strip- Adh. Back Seal Strip- Adh. Back Seal Strip- Adh. Back Seal Strip- Adh. Back Drip Pan- Motor until 8/ Drip Pan- Motor 9/02 & later Drain Pan Assy LH Drain Pan Assy RH Drain Pan Assy LH Drain Pan Assy RH Drain Pan Assy LH Drain Pan Assy RH Drain Pan Assy LH Drain Pan Assy RH Drain Pan Assy LH Drain Pan Assy RH Assy, Drain Pan, Outer LH Assy, Drain Pan, Outer RH Assy, Drain Pan, Outer LH Assy, Drain Pan, Outer RH Assy, Drain Pan, Outer LH Assy, Drain Pan, Outer RH Assy, Drain Pan, Outer LH Assy, Drain Pan, Outer RH Assy, Drain Pan, Outer LH Assy, Drain Pan, Outer RH Insulation- Fiberglass Gasket- Adhesive Backed K 1 Gasket- Adhesive Backed K 1 Gasket- Adhesive Backed K 1 1 Gasket- Adhesive Backed K 1 Gasket- Adhesive Backed K 1 N/S Secondary Drain Pan, Galv. RH N/S Secondary Drain Pan, Galv. LH N/S Secondary Drain Pan, SS RH N/S Secondary Drain Pan, SS LH N/S = Not Shown on diagram. 1 Please contact Daikin with unit model and serial number for part numbers on Cabinet components. 031F/S03 041F/S04 061F/S06 081F/S08 101F/S10 121F/S12 Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 14
15 Coils TSC/TSH 031F Coil Part Description Number Cooling Coil, Standard- 2 Row, 12 FPI- 8¾" x 19" Cooling Coil, High Capacity- 3 Row, 12 FPI- 8¾" x 19" Reheat Coil- 1 Row Water- 7" x 15¾" Reheat Coil- 1 Row Steam- 7½" x 15" FTSC/FTSH S03 Designs A & B Coil FTSC/FTSH FTSC/FTSH FTSC/FTSH Part Description 3 C03= C06= C07= Number Cooling Coil, Standard- 2 Row 8¾" x 19" 1 (Des. A) A 00,70, Cooling Coil, Standard- 2 Row 8¾" x 19" 2 (Des. B) A 00,70, Cooling Coil, High Cap.- 3 Row 8¾" x 19" 1 (Des. A) C 00,70, Cooling Coil, High Cap.- 3 Row 8¾" x 19" 2 (Des. B) C 00,70, Heating Coil- 1 Row Water- 7" x 15¾" 1, 2 A or C Heating Coil- 1 Row Steam- 7½" x 15" 1, 2 C The approximate date for the design (vintage) change was Oct., Consult Nameplate or G.O. to determine design (see nomenclature page for full unit definition). TSC/TSH 041F Coil Part Description Number Cooling Coil, Standard- 2 Row, 12 FPI- 8¾" x 25" Cooling Coil, High Capacity- 3 Row, 12 FPI- 8¾" x 25" Reheat Coil- 1 Row Water- 7" x 21¾" Reheat Coil- 1 Row Steam- 7½" x 21" FTSC/FTSH S04 Designs A & B Coil FTSC/FTSH FTSC/FTSH FTSC/FTSH Part Description 3 C03= C06= C07= Number Cooling Coil, Standard- 2 Row 8¾" x 25" 1 (Des. A) A 00,70, Cooling Coil, Standard- 2 Row 8¾" x 25" 2 (Des. B) A 00,70, Cooling Coil, High Cap.- 3 Row 8¾" x 25" 1 (Des. A) C 00,70, Cooling Coil, High Cap.- 3 Row 8¾" x 25" 2 (Des. B) C 00,70, Heating Coil- 1 Row Water- 7" x 21¾" 1, 2 A or C Heating Coil- 1 Row Steam- 7½" x 21" 1, 2 C The approximate date for the design (vintage) change was Oct., Consult Nameplate or G.O. to determine design (see nomenclature page for full unit definition). Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 15
16 Coils TSC/TSH 061F Coil Part Description Number Cooling Coil, Standard- 2 Row, 12 FPI- 8¾" x 34" Cooling Coil, High Capacity- 3 Row, 12 FPI- 8¾" x 34" Reheat Coil- 1 Row Water- 7" x 30¾" Reheat Coil- 1 Row Steam- 7½" x 30" FTSC/FTSH S06 Designs A & B Coil FTSC/FTSH FTSC/FTSH FTSC/FTSH Part Description 3 C03= C06= C07= Number Cooling Coil, Standard- 2 Row 8¾" x 34" 1 (Des. A) A 00,70, Cooling Coil, Standard- 3 Row 8¾" x 34" 2 (Des. B) A 00,70, Cooling Coil, High Cap.- 3 Row 8¾" x 34" 1 (Des. A) C 00,70, Cooling Coil, High Cap.- 4 Row 8¾" x 34" 2 (Des. B) C 00,70, Heating Coil- 1 Row Water- 7" x 30¾" 1, 2 A or C Heating Coil- 1 Row Steam- 7½" x 30" 1, 2 C The approximate date for the design (vintage) change was Oct., Consult Nameplate or G.O. to determine design (see nomenclature page for full unit definition). TSC/TSH 081F Coil Part Description Number Cooling Coil, Standard- 3 Row, 9 FPI- 8¾" x 34" Cooling Coil, High Capacity- 3 Row, 12 FPI- 8¾" x 34" Reheat Coil- 1 Row Water- 7" x 30¾" Reheat Coil- 1 Row Steam- 7½" x 30" FTSC/FTSH S08 Designs A & B Coil FTSC/FTSH FTSC/FTSH FTSC/FTSH Part Description 3 C03= C06= C07= Number Cooling Coil, Standard- 3 Row 8¾" x 34" 1 (Des. A) A 00,70, Cooling Coil, Standard- 3 Row 8¾" x 34" 2 (Des. B) A 00,70, Cooling Coil, High Cap.- 3 Row 8¾" x 34" 1 (Des. A) C 00,70, Cooling Coil, High Cap.- 4 Row 8¾" x 34" 2 (Des. B) C 00,70, Heating Coil- 1 Row Water- 7" x 30¾" 1, 2 A or C Heating Coil- 1 Row Steam- 7½" x 30" 1, 2 C The approximate date for the design (vintage) change was Oct., Consult Nameplate or G.O. to determine design (see nomenclature page for full unit definition). Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 16
17 TSC/TSH 101F Coils Coil Part Description Number Cooling Coil, Standard- 3 Row, 9 FPI- 8¾" x 42" Cooling Coil, High Capacity- 3 Row, 12 FPI- 8¾" x 42" Reheat Coil- 1 Row Water- 7" x 38¾" Reheat Coil- 1 Row Steam- 7½" x 38" FTSC/FTSH S10 Designs A & B Coil FTSC/FTSH FTSC/FTSH FTSC/FTSH Part Description 3 C03= C06= C07= Number Cooling Coil, Standard- 3 Row 8¾" x 42" 1 (Des. A) A 00,70, Cooling Coil, Standard- 3 Row 8¾" x 42" 2 (Des. B) A 00,70, Cooling Coil, High Cap.- 3 Row 8¾" x 42" 1 (Des. A) C 00,70, Cooling Coil, High Cap.- 4 Row 8¾" x 42" 2 (Des. B) C 00,70, Heating Coil- 1 Row Water- 7" x 38¾" 1, 2 A or C Heating Coil- 1 Row Steam- 7½" x 38" 1, 2 C The approximate date for the design (vintage) change was Oct., Consult Nameplate or G.O. to determine design (see nomenclature page for full unit definition). TSC/TSH 121F Coil Part Description Number Cooling Coil, Standard- 3 Row, 9 FPI- 8¾" x 58" Cooling Coil, High Capacity- 3 Row, 12 FPI- 8¾" x 58" Reheat Coil- 1 Row Water- 7" x 54¾" Reheat Coil- 1 Row Steam- 7½" x 54" FTSC/FTSH S12 Designs A & B Coil FTSC/FTSH FTSC/FTSH FTSC/FTSH Part Description 3 C03= C06= C07= Number Cooling Coil, Standard- 3 Row 8¾" x 58" 1 (Des. A) A 00,70, Cooling Coil, Standard- 3 Row 8¾" x 58" 2 (Des. B) A 00,70, Cooling Coil, High Cap.- 3 Row 8¾" x 58" 1 (Des. A) C 00,70, Cooling Coil, High Cap.- 4 Row 8¾" x 58" 2 (Des. B) C 00,70, Heating Coil- 1 Row Water- 7" x 54¾" 1, 2 A or C Heating Coil- 1 Row Steam- 7½" x 54" 1, 2 C The approximate date for the design (vintage) change was Oct., Consult Nameplate or G.O. to determine design (see nomenclature page for full unit definition). Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 17
18 Fan Deck Assembly Diagrams Unit Sizes 061F & 081F/ S06 & S Unit Sizes 031F & 041F/ S03 & S Fan Detail (sizes 06/08 shown) Unit Size 101F/ S10 Unit Size 121F/ S12 Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 18
19 Fan Deck Assembly Components Unit Size/ Quantity Ref. No. Part Description Part Number 031F/S03 041F/S04 061F/S06 081F/S08 101F/S10 121F/S12 1 Fan Deck Fan Deck Fan Deck Fan Deck Fan Deck Fan Housing, Discharge Half Fan Housing, Access Half Motor See chart on next pages. 6 Cap, Capacitor Motor Mount See chart on next pages. 8 Clamp, Motor Mount Clamp, Wheel Hub Mounting Wheel, Blower Capacitor See chart on next pages. N/S Cabinet/Chassis Components Please contact Daikin with unit model and serial number for part numbers on Cabinet components. Complete Fan Deck Assy 4 Part Description Fan Deck Assembly, Standard Motor 5 4 Assembly contains all components illustrated in the diagrams on the previous page. 5 The fan motors were offered as "Standard" or "Hi-Static" on the older models. The FTSC/FTSH units are all "standard motors" /50/1 is not offered on the FTSC/FTSH units. N/A= Not Applicable. Unit Sizes 031F/S03 041F/S04 061F/S06 081F/S08 101F/S10 121F/S12 115/60/1V /50/1V /60/1V Fan Deck Assembly, High Static Motor 5 115/60/1V N/A /60/1V N/A Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 19
20 TSC/TSH 031F Fan Motor, Capacitor, Motor Mount Motor Description Voltage Motor Capacitor Mount Single Shaft- Standard 115/60/ Single Shaft- Standard 277/60/ The original motor used capacitor If ordering a new motor the capacitor should also be ordered. 9 The motors listed here are replacements for the now obsolete original motors. When ordering a new motor, a new mount should also be ordered. FTSC/FTSH S03 Motor Description Voltage Motor Capacitor Mount Single Shaft- Standard 115/60/ Single Shaft- Standard 277/60/ TSC/TSH 041F Motor Description Voltage Motor Capacitor Mount Single Shaft- Standard 115/60/ Single Shaft- Standard 277/60/ Single Shaft- Standard 230/50/ Single Shaft- High Static 115/60/ Single Shaft- High Static 277/60/ The motors listed here are replacements for the now obsolete original motors. When ordering a new motor, a new mount should also be ordered. FTSC/FTSH S04 Motor Description Voltage Motor Capacitor Mount Single Shaft- Standard 115/60/ Single Shaft- Standard 277/60/ Single Shaft- High Static /60/ Single Shaft- High Static /60/ High Static is not a standard option. These units are specials and noted as such in the nomenclature (a standard unit would be FTSC2S04..., a Hi-Stat special is FTSC2H04...) Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 20
21 TSC/TSH 061F Fan Motor, Capacitor, Motor Mount Continued Motor Description Voltage Motor Capacitor Mount Double Shaft- Standard 115/60/ Double Shaft- Standard 277/60/ Double Shaft- Standard 230/50/ Double Shaft- High Static 115/60/ Double Shaft- High Static 277/60/ The original motor used capacitor (115V) or (277V). If ordering a new motor the capacitor should also be ordered. 9 The motors listed here are replacements for the now obsolete original motors. When ordering a new motor, a new mount should also be ordered. FTSC/FTSH S06 Motor Description Voltage Motor Capacitor Mount Double Shaft- Standard 115/60/ Double Shaft- Standard 277/60/ Double Shaft- High Static /60/ Double Shaft- High Static /60/ High Static is not a standard option. These units are specials and noted as such in the nomenclature (a standard unit would be FTSC2S06..., a Hi-Stat special is FTSC2H06...) TSC/TSH 081F Motor Description Voltage Motor Capacitor Mount Double Shaft- Standard 115/60/ Double Shaft- Standard 277/60/ Double Shaft- Standard 230/50/ Double Shaft- High Static 115/60/ Double Shaft- High Static 277/60/ The original motor used capacitor If ordering a new motor the capacitor should also be ordered. 9 The motors listed here are replacements for the now obsolete original motors. When ordering a new motor, a new mount should also be ordered. FTSC/FTSH S08 Motor Description Voltage Motor Capacitor Mount Double Shaft- Standard 115/60/ Double Shaft- Standard 277/60/ Double Shaft- High Static /60/ Double Shaft- High Static /60/ High Static is not a standard option. These units are specials and noted as such in the nomenclature (a standard unit would be FTSC2S08..., a Hi-Stat special is FTSC2H08...) Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 21
22 Fan Motor, Capacitor, Motor Mount Continued TSC/TSH 101F Motor Description Voltage Motor Capacitor Mount Single Shaft- Standard /60/ Single Shaft- Standard /60/ Single Shaft- Standard /50/ Single Shaft- Standard /60/ Single Shaft- Standard /60/ Single Shaft- Standard /50/ Single Shaft- Standard /60/ A Single Shaft- High Static 277/60/ A Double Shaft- Standard 115/60/ Double Shaft- Standard 277/60/ Double Shaft- Standard 230/50/ Double Shaft- High Static 115/60/ Double Shaft- High Static 277/60/ The original motor used capacitor If ordering a new motor the capacitor should also be ordered. 8A The original motor used capacitor (115V) or (277V). If ordering a new motor the capacitor should also be ordered. 9 The motors listed here are replacements for the now obsolete original motors. When ordering a new motor, a new mount should also be ordered. 11 These motors used on units built before Revision Level These motors used on units built Revision Level 02 and later. FTSC/FTSH S10 Motor Description Voltage Motor Capacitor Mount Single Shaft- Standard 115/60/ Single Shaft- Standard 277/60/ Single Shaft- High Static /60/ Single Shaft- High Static /60/ Double Shaft- Standard 115/60/ Double Shaft- Standard 277/60/ Double Shaft- High Static /60/ Double Shaft- High Static /60/ High Static is not a standard option. These units are specials and noted as such in the nomenclature (a standard unit would be FTSC2S10..., a Hi-Stat special is FTSC2H10...) Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 22
23 TSC/TSH 121F (Qty.= 2 of each component) Motor Description Voltage Motor Capacitor Mount Double Shaft- Standard 115/60/ Double Shaft- Standard 277/60/ Double Shaft- Standard 230/50/ Double Shaft- High Static 115/60/ Double Shaft- High Static 277/60/ The original motor used capacitor If ordering a new motor the capacitor should also be ordered. 9 The motors listed here are replacements for the now obsolete original motors. When ordering a new motor, a new mount should also be ordered. Fan Motor, Capacitor, Motor Mount Continued FTSC/FTSH S12 (Qty.= 2 of each component) Motor Description Voltage Motor Capacitor Mount Double Shaft 115/60/ Double Shaft 277/60/ Double Shaft- High Static /60/ Double Shaft- High Static /60/ High Static is not a standard option. These units are specials and noted as such in the nomenclature (a standard unit would be FTSC2S12..., a Hi-Stat special is FTSC2H12...) Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 23
24 Cabinet Assembly- TSC/FTSC Diagram 202 Bottom Return Shown Base Unit Ref Use for Sizes 03, 04, 101 only Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 24
25 Cabinet Assembly- TSC/FTSC Components Ref Description Part No. Number 202 Panel Assy- Top- Insulated Transition Assy - Insulated Clip, S-type Baffle, Transition Discharge Panel Assy, Insulated Discharge Panel Assy - Standard Discharge Panel Assy, Insulated Discharge Panel Assy - Standard Discharge Panel Assy, Insulated Discharge Panel Assy - Standard Back Panel Assy - Insulated Discharge Panel Assy - Standard Back Panel Assy - Insulated Discharge Panel Assy - Standard Back Panel Assy - Insulated Discharge Panel Assy - Standard Back Panel Assy - Insulated Back Panel Assy - Standard Back Panel Assy - Insulated Back Panel Assy - Standard Back Panel Assy - Insulated Back Panel Assy - Standard Back Panel Assy - Insulated Back Panel Assy - Standard Back Panel Assy - Insulated Back Panel Assy - Standard Back Panel Assy - Insulated Back Panel Assy - Standard Spring- Filter End Panel Assy - Insulated End Panel Assy - Standard NOTE: Insulated Cabinets= Standard panels + insulation. Insulated cabinets used on TSC units only. NOTE: All part numbers listed in italics are NOT set up WDSII (not orderable). Please contact Daikin. 14 Stamped Grille is only option for the front discharge on FTSC units only (C10=AY). 15 Rear return- Duct Opening for FTSC until 3/11 Code11=20 and Code 37 for FTSC 3/11 & later. 16 Bottom return- Blank (stamped grille) for FTSC until 3/11 Code11= F/S03 041F/S04 Unit Size 061F/S06 081F/S08 101F/S10 121F/S12 Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 25
26 Cabinet Assembly- TSC/FTSC Components, Continued Ref Description Part No. Number 215 Bottom Panel Assy - Insulated Bottom Panel Assy - Standard Bottom Panel Assy - Insulated Bottom Panel Assy - Standard Bottom Panel Assy - Insulated Bottom Panel Assy - Standard Access Panel Assy- Insulated Access Panel Assy - Standard Access Panel Assy- Insulated Access Panel Assy - Standard Access Panel Assy- Insulated Access Panel Assy - Standard Access Panel Assy- Insulated Access Panel Assy - Standard Access Panel Assy- Insulated Access Panel Assy - Standard Access Panel Assy- Insulated Access Panel Assy - Standard NS Nut, Spring- J Type NS Hinge Pin NS Filter, Throwaway Filter, TA (12 pack of ) NS Filter, Throwaway Filter, TA (12 pack of ) NS Filter, Throwaway Filter, TA (12 pack of ) NS Filter, Cleanable x 9.88 x NS Filter, Cleanable X NS Filter, Cleanable X 9.88 X F/S03 041F/S04 Unit Size NOTE: Insulated panal assy= Standard panel assy + insulation. Insulated cabinets used on TSC units only. N/S= Not Shown on Diagram. 15 Rear return- Stamped grille for FTSC until 3/11 Code11=20 and Code 37 for FTSC 3/11 & later. 16 Bottom return- Blank panel for FTSC until 3/11 Code11= F/S06 081F/S08 101F/S10 121F/S12 Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 26
27 Electric Heaters- TSC/TSH F Vintage (Electric Heat is a field installed option for the FTSC/FTSH Designs A & B. See the Field Installed Accessories section for kit and individual part numbers) Volts/ Heater Part 031F/ 061F/ 101F 121F Watts Description Number 041F 081F 120V/1 KW Heater, Electric - 120V V/2 KW Heater, Electric V V/1 KW Heater, Electric - 208V V/2 KW Heater, Electric - 208V V/3 KW Heater, Electric - 208V V/1 KW Heater, Electric - 240V V/2 KW Heater, Electric - 240V V/3 KW Heater, Electric - 240V V/1 KW Heater, Electric - 277V V/2 KW Heater, Electric - 277V V/3 KW Heater, Electric - 277V V/2 KW Heater, Electric - 120V V/2 KW Heater, Electric - 208V V/4 KW Heater, Electric - 208V V/6 KW Heater, Electric - 208V V/2 KW Heater, Electric - 240V V/4 KW Heater, Electric - 240V V/6 KW Heater, Electric - 240V V/2 KW Heater, Electric - 277V V/4 KW Heater, Electric - 277V V/6 KW Heater, Electric - 277V Unit Size 208V/4 KW Heater, Electric - 208V Heater, Electric - 208V V/6 KW Heater, Electric - 208V V/4 KW Heater, Electric - 240V Heater, Electric - 240V V/6 KW Heater, Electric - 240V V/4 KW Heater, Electric - 277V Heater, Electric - 277V V/6 KW Heater, Electric - 277V V/8 KW Heater, Electric - 277V Heater, Electric - 277V V/4 KW Heater, Electric - 208V V/6 KW Heater, Electric - 208V Heater, Electric - 208V V/4 KW Heater, Electric - 240V V/6 KW Heater, Electric - 240V Heater, Electric - 240V V/4 KW Heater, Electric - 277V V/6 KW Heater, Electric - 277V Heater, Electric - 277V V/8 KW Heater, Electric - 277V Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 27
28 Electric Heater Control Components- TSC/TSH "F" (The parts used and installed vary per unit. The vendor nomenclature on the actual part and/or the unit serial or GO number are required for part identification) Description Part No. 1PST Relay, 120V Coil, 18 Amp PST Relay, 230V Coil, 18 Amp PST Relay, 277V Coil, 18 Amp Control, Limit Switch O F Control, Limit Switch O F Control, Limit Switch O F Control, Limit Switch O F Control, Limit Switch O F Control, Limit Switch O F Control, Limit Switch O F Valves and Air Vent Kits- TSC/TSH "F" Unit Part Part Qty. Voltage Description Number 120V Control ValveBody- 2 Way Actuator V Control Valve Body- 3 Way Actuator V Control Valve (includes Motor), 2-Way V Control Valve (includes Motor), 3-Way V Control ValveBody- 2 Way Actuator V Control ValveBody- 3 Way Actuator V Valve Motor Only V Valve Motor Only V Valve Motor Only Valve- Balancing Until 2/ Valve- Balancing 2/04 & later Valve, Ball- T Handle Until 2/ Valve, Ball- T Handle 2/04 & later Valve, Water- Manual Vent Kit- Air Switch Assembly Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 28
29 Field Installed Accessories- TSC/TSH "F" Units Wall Mounted Thermostats & Speed Switches Themostat Description Part No. Type 1 3-Speed Switch, Wall Mounted SPDT Wall Mounted * Manual Changeover Subbase Speed Switch, Wall Mounted SPDT Wall Mounted * * 3-Speed Switch, Wall Mounted SPDT Wall Mounted Thermostat/ 4* * * 3-Speed Switch with Manual Changeover SPDT Wall Mounted Combination Thermostat/ 5 3-Speed Switch DPDT Wall Mounted - Dead Band * * 3-Speed Switch, Wall Mounted DPDT Wall Mounted Combination Thermostat/ 8 3-Speed Switch (Dead Band) * Thermostat, Manual C/O, Subbase and Speed Switch must be ordered seprarately for control systems requiring T-stat Type 2. * * Both T-stat and 3-Speed Switch must be ordered separately for control systems requiring thermostat type 3 or 7. * * * Thermostat can be used for only one mode at a time. Not a combination (either heating only OR cooling only). Secondary Drain Pan Description Unit Hand Part Number Must be ordered separately when valves are field supplied. Left For 2- and 3-Way Valves. Right Trim Flange for TSC Units Description Unit Size Part No. Telescopically adjustable ceiling frame to provide finished look to 031F, 041F perimeter of TSC units in drop ceiling applications 061F, 081F F, 121F Automatic Air Vent Description Unit size Part No. Replaces standard manual air vent in chilled & hot water coils All Automatic Changeover Description Assy Stat Only Clip Automatic Changeover (Strap-on Aquastat Type) Switches and Circuit Breaker Description Assy Disconnect Switch- Toggle Automatic Changeover Switch Circuit Breaker- 115V only, units without Electric Heat Fan Coil; TSH,TSC F/FTSH,FTSC 03-12, Des. A/B Rev. R 12/17 RPL / Page 29
Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015
Replacement Parts List No. 700027600 Revision D 02/2015 Daikin McQuay Packaged Terminal Air Conditioner PGAN 007, 009, 012, 015 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationMcQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000
Replacement s List No. 5709900 Revision N 0/205 McQuay Incremental MQE 007, 009, 02, 05, 06 MQR 007, 009, 02, 05 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call -800-377-2787
More informationDaikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)
Replacement Parts List No. 700018800 Revision C 08/2012 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design D (4) To find your Daikin Applied parts distributor,
More informationDaikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017
Replacement Parts List No. 700028400 Revision A 07/207 Daikin McQuay Incremental PKEI, PKES, PKHS 07-09 Design 2 To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com
More informationMcQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1)
Replacement Parts List No. 110509900 Revision E 07/2016 McQuay Incremental PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1) To find your Daikin Applied
More informationMcQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994
Replacement Parts List No. 05708900 Revision C 06/205 McQuay Incremental Packaged Terminal Air Conditioner MQT 06-4 Vintage B Last Manufactured: 994 To find your Daikin Applied parts distributor, call
More informationMcQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991
Replacement Parts List No. 055203500 Revision G 05/206 McQuay Climate Control Singer Incremental ES, RS, S 06, 09,, 4 Vintage B Last Manufactured: 99 To find your Daikin Applied parts distributor, call
More informationMcQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017
Replacement s List 055208000 Revision E 08/207 McQuay Incremental MQS 007-05 Vintages A 02-05 Vintage B Last Manufactured: 993 To find your Daikin Applied parts distributor, call -800-377-2787 or visit
More informationMcQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998
Replacement Parts List No. 04765700 Revision E 04/08 McQuay Roofpak Roof Mounted Air Handler Draw- Through RDS Size: 900 Vintage: B Last Manufactured: 998 To find your Daikin Applied parts distributor,
More informationAAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016
Replacement Parts List No. 057117300 Revision D 08/2016 AAF Water Source Heat Pump Ceiling Mounted CCW 019-060 Vintage E Last Manufactured: 1999 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationDaikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 007, 009, 012 Design 1. Replacement Parts List No Revision M 11/2017
Replacement Parts List No. 700013000 Revision M 11/2017 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationDaikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision O 11/2017
Replacement Parts List No. 700013100 Revision O 11/2017 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationMcQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993
Replacement s List No. 55209100 Revision E 10/2015 McQuay Console Water Source Heat Pump WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A Last Manufactured: 1993 To find your Daikin Applied parts distributor,
More informationMcQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018
Replacement Parts List No. 70006800 Revision D 03/208 McQuay Enfinity Vertical Water Source Heat Pump WFCV, WFCW 007-02 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit
More informationDaikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision R 11/2018
Replacement Parts List No. 700013100 Revision R 11/2018 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationMcQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1)
Replacement Parts List No. 110510700 Revision G 02/2015 McQuay Concealed Ceiling Water Source Heat Pump WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1) WCAS, WCDA, WCDL, WCDS, WCMS 030 Design
More informationMcQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995
Replacement Parts List No. 055236000 Revision B 06/2015 McQuay Ceiling Concealed Horizontal Water Source Heat Pump CCH, CCG, CCW 048, 060 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts
More informationMcQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017
Replacement Parts List No. 700016700 Revision A 07/2017 McQuay Console Water Source Heat Pump WWDU 07-15 Design A Last Manufactured: 2005 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationSeasonMaker ThinLine Fan-coil Units
Catalog C: 720-12 SeasonMaker ThinLine Fan-coil Units Type TSH & TSC Horizontal Design TSS, TPF, TSF & TSB Vertical Design C L I S T E D Ratings Certified by the Air Conditioning & Refrigeration Institute
More informationDaikin. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 2. Replacement Parts List No New 11/2017
Replacement Parts List No. 700053300 New 11/2017 Daikin Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit
More informationMcQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993
Replacement Parts List No. 055237600 Revision D 08/2017 McQuay Vertical Water Source Heat Pump FCV, FCG, FCW 036, 042 Vintage A Last Manufactured: 1993 To find your Daikin Applied parts distributor, call
More informationDaikin. Self-Contained Unit Ventilator. UAEQ 036, 044, 054 Design H (8) Replacement Parts List No New 11/2017
Replacement Parts List No. 70005300 New /207 Daikin Self-Contained Unit Ventilator UAEQ 036, 044, 054 Design H (8) To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com
More informationSeasonMaker ThinLine Fan-coil Units
Catalog C: 720-12 SeasonMaker ThinLine Fan-coil Units Type TSH & TSC Horizontal Design TSS, TPF, TSF & TSB Vertical Design C L I S T E D Ratings Certified by the Air Conditioning & Refrigeration Institute
More informationMcQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988
Replacement Parts List No. 055204700 Revision D 01/2017 McQuay Climate Control Horizontal Water Source Heat Pump CC, CG, CW, UC, UG, UW 610-630 Vintages E, F, G Last Manufactured: 1988 To find your Daikin
More informationMcQuay. Large Vertical Water Source Heat Pump. LGP, LHP, LWP Vintage C. Last Manufactured: 1994
Replacement Parts List 0570900 Revision F 09/06 McQuay Large Vertical Water Source Heat Pump LGP, LHP, LWP 07-7 Vintage C Last Manufactured: 994 To find your Daikin Applied parts distributor, call -800-77-787
More informationMcQuay. Self-Contained Unit Ventilator. UAZQ, UAZR, UAZU Design G (7) Replacement Parts List No Revision D 08/2018
Replacement Parts List No. 700051500 Revision D 08/2018 McQuay Self-Contained Unit Ventilator UAZQ, UAZR, UAZU 024-054 Design G (7) To find your Daikin Applied parts distributor, call 1-800-377-2787 or
More informationMcQuay. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. WCDD, WCDE, WCMG Design A (1) WCDD, WCDE Design B (2)
Replacement Parts List No. 057117200 Revision G 08/2016 McQuay Water Source Heat Pump Ceiling Mounted CCW 019-060 Vintage E WCDD, WCDE, WCMG 019-060 Design A (1) WCDD, WCDE 019-060 Design B (2) To find
More informationMcQuay. Aircon Air Cooled Condenser. AMB, APB AMD, APD Vintage A. Last Manufacture: 1978
Replacement Parts List No. 055224800 Revision C 10/2017 McQuay Aircon Air Cooled Condenser AMB, APB 020-140 AMD, APD 008-030 Vintage A Last Manufacture: 1978 To find your Daikin Applied parts distributor,
More informationCatalog ThinLine Horizontal Fan Coils. Type FCHC, FCHH and FCHR. Exposed Horizontal Cabinet. Recessed Horizontal Cabinet
ThinLine Horizontal Fan Coils Type FCHC, FCHH and FCHR Catalog 724-5 Exposed Horizontal Cabinet Recessed Horizontal Cabinet Concealed Horizontal Model Table of Contents Nomenclature and Certification...
More informationCatalog ThinLine Vertical Fan Coils. Type FCVC, FCVH, FCVS Vertical Design. Model FCVC. Model FCVS
Catalog 722-6 ThinLine Vertical Fan Coils Type FCVC, FCVH, FCVS Vertical Design Model FCVC Model FCVS Table of Contents Table of Contents Nomenclature and Certification... 3 ThinLine Vertical Fan Coils...
More informationVertical V*B Series Fan Coil Technical Catalog
Vertical V*B Series Fan Coil Technical Catalog Vertical Hideaway (VCB) 200 CFM to 1200 CFM The Vertical Hideaway (VCB) fan coil unit is designed for concealed applications. The coil section is lined with
More informationCatalog ThinLine Horizontal Fan Coils. Type FCHC, FCHH and FCHR. Exposed Horizontal Cabinet. Recessed Horizontal Cabinet
ThinLine Horizontal Fan Coils Type FCHC, FCHH and FCHR Catalog 724-8 Exposed Horizontal Cabinet Recessed Horizontal Cabinet Concealed Horizontal Model Table of Contents Nomenclature and Certification...
More informationCatalog ThinLine Vertical Fan Coils. Type FCVC, FCVH, FCVS Vertical Design. Model FCVC. Model FCVS
Catalog 722-8 ThinLine Vertical Fan Coils Type FCVC, FCVH, FCVS Vertical Design Model FCVC Model FCVS Table of Contents Table of Contents Nomenclature and Certification... 3 ThinLine Vertical Fan Coils...
More informationMcQuay. Commercial Unitary Rooftop. CUR Vintage G. Last Manufactured: Replacement Parts List No Revision A 11/2016
Replacement Parts List No. 057102700 Revision A 11/2016 McQuay Commercial Unitary Rooftop CUR 075-150 Vintage G Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationMcQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012
Replacement s List No. 700024500 New 07/2012 McQuay Screw Chiller Water Cooled WHS 155-200 Vintage A Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit
More informationLarge Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models
Large Capacity Fan Coil Units Catalog 735-12 Belt-Drive and Direct-Drive Cabinet and Hideaway Models Table of Contents Agency Listing and Nomenclature... 3 Overview....................................
More informationWE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL
PREPARED FOR: DATE: JOB NAME: WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL EQUIPMENT DETAILS ITEM TAG DESCRIPTION MODEL NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 EQUIPMENT
More informationCatalog ThinLine Vertical Unit Heaters. Type FHVC, FHVH, FHVS, FHWC Vertical Design. Model FHVC. Model FHVS
ThinLine Vertical Unit Heaters Type FHVC, FHVH, FHVS, FHWC Vertical Design Catalog 723-3 Model FHVC Model FHVS Nomenclature and Certification... 3 ThinLine Vertical Unit Heaters...3 AHRI Certification...3
More informationMcQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007
Replacement Parts List No. 700002400 Revision D 11/2009 McQuay Acson Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR 20-50 Last Manufactured: 2007 To find your Daikin Applied
More informationProduct Specifications. Vertical Floor Consoles By First Co.
NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series
More informationDaikin McQuay. Applied PTAC Air Conditioner and Heat Pump. PDAA, PDAE, PDAF, PDAN, PDHA, PDHE, PDHF Design 3
Replacement Parts List No. 70002700 Revision G 02/204 Daikin McQuay Applied PTAC Air Conditioner and Heat Pump PDAA, PDAE, PDAF, PDAN, PDHA, PDHE, PDHF 007-07 Design 3 To find your Daikin Applied parts
More informationCatalog C: McQuay Horizontal Concealed Fan Coil Unit
Catalog C: 700-1 McQuay Horizontal Concealed Fan Coil Unit Model THC Sizes 200 Through 1200 CFM McQuay THC Horizontal Concealed Fan Coil Nomenclature F THC 1 H02 Fan-coil Type of Unit THC = Horizontal
More informationLarge Capacity Fan Coil Units Belt and Direct Drive Cabinet and Hideaway
Catalog C: 735-7 Large Capacity Fan Coil Units Belt and Direct Drive Cabinet and Hideaway Direct Drive CUL Listed McQuay Large Capacity Fan Coil Units Page 2 / Catalog 735 Direct drive hideaway unit The
More informationSubmittal. RBVR Vertical Concealed Floor Mount FCU RBVR
FCU RBVR 1.0 07 25 18 RBVR Vertical Concealed Floor Mount Unit Size 02 03 04 06 08 10 A 23 3/16 [589] 27 3/16 [691] 33 3/16 [843] 43 3/16 [1097] 45 3/16 [1148] 59 3/16 [1503] B 22 ¾ [578] 26 ¾ [679] 32
More informationH3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog
H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...
More informationMcQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E
Replacement Parts List No. 700008400 Revision V 04/2018 McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 030, 035, 040, 050 Vintage A, E To find your Daikin Applied parts distributor,
More informationengineering guide FH Fan-Coil Units Low-Profile, Horizontal
engineering guide FH Fan-Coil Units Low-Profile, Horizontal FORM 115.26-EG7 (908) Table of contents FH Fan-Coil Units Low-Profile, Horizontal Features and Benefits... Construction Features... Standard
More informationClimate Control Singer. Incremental Comfort Systems. KS, EKS Vintage B. Last Manufactured: 1982
Replacement s List No. 055202900 Revision A 11/1999 Climate Control Singer Incremental Comfort Systems KS, EKS 07-15 Vintage B Last Manufactured: 1982 To find your Daikin Applied parts distributor, call
More informationBUILD YOUR REPUTATION ON OURS. Universal Modular Hi-Rise Series FAN COIL TECHNICAL CATALOG
BUILD YOUR REPUTATION ON OURS Universal Modular Hi-Rise Series FAN COIL TECHNICAL CATALOG TABLE OF CONTENTS 2 Table of Contents 3 Universal Modular Hi-Rise Family 4 Features and benefits 5 Product Application
More informationInstallation Manual IM
Installation Manual IM 255-10 HiLine Fan Coil Unit Models FHSS 103 through 108 Group: Fan Coils Part Number: 910227748 Date: January 2018 2018 Daikin Applied Table of Contents Table of Contents General
More informationFCC Fan-Coil Units High-Performance, Vertical
FCC Fan-Coil s High-Performance, Vertical Model FCC construction features Piping and supply-duct connections are from top of unit, eliminating the need for side or back access Right or left-hand configurations
More informationMcQuay. Applied PTAC Air Conditioner and Heat Pump PDAC, PDAA, PDAE, PDAN, PDAF PDHP, PDHA, PDHE, PDHF Design 1
Replacement Parts List No. 700008800 Revision M 02/2014 McQuay Applied PTAC Air Conditioner and Heat Pump PDAC, PDAA, PDAE, PDAN, PDAF 007-017 PDHP, PDHA, PDHE, PDHF 007-015 Design 1 To find your Daikin
More informationMcQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 020, 025 Vintage E. Replacement Parts List No Revision J 02/2018
Replacement Parts List No. 700014900 Revision J 02/2018 McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 020, 025 Vintage E To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationAir Cooled Scroll Compressor Condensing Unit
Replacement Parts List No. 70000900 Rev. B 2/08 Air Cooled Scroll Compressor Condensing Unit ACZ Sizes: 00-039 Vintage: B R22, R407C Contents Contents... 2 Parts List Revision History... 3 Nomenclature
More informationVertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump
VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...
More informationHydronic Heating Fan Coils Radiant ceiling systems Water Source Heat Pumps Horizontal Room Fan Coils
Hydronic Heating Fan Coils Radiant ceiling systems Water Source Heat Pumps Horizontal Room Fan Coils Catalog Zehnder everything you need to create a comfortable, healthy and energy-efficient indoor climate
More informationInstallation and Maintenance Manual IM 254-7
Installation and Maintenance Manual IM 254-7 HiLine Vertical Stacking Fan Coil Unit Group: Fan Coils Part Number: 910227750 Date: January 2018 Models FHSK 103 through 108 Table of Contents Table of Contents
More informationMulti-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers
Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers 60 HZ Convertible Air Handlers Model: Series 2 Air Handlers 1.5-3 ton Standard Coil Black Epoxy Coil GAF2A0A18S11SE GAF2A0A18S11EE
More informationComplete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A
Publication No. WT-CSX-0616A Central Station Air Handling Units Complete HVAC Capability Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels
More informationVertiCool Aurora Engineering Guide
Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8
More informationVERTICAL FAN COIL UNITS
VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote
More informationCooling/Heat Pump Convertible Air Handlers
Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18B1000A 2/4TEC3F24B1000A 2/4TEC3F30B1000A 2/4TEC3F36B1000A 2/4TEC3F42C1000A 2/4TEC3F48B1000A 2/4TEC3F55B1000A 2/4TEC3F60B1000A 1½ 5 Ton PUB. NO. 22-1774-17
More informationMHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH
MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:
More informationMHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH
MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH
More informationModular Multi-position Air Handler
Modular Multi-position Air Handler Air Handler - Convertible Model: Series 2 Air Handler 3 ton with high efficiency motor GAF2A0A36M31SA PUB. NO. 22-1862-01 Features and Benefits Unique Cabinet Design
More informationFAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design
FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design Fan motor (PSC or ECM). UL Listed 1 insulation conforms to UL Test 181 and NFPA 90A. Plenum air filter rack. (Filter Optional) Casing has
More informationSPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED
(491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes
More informationCabinet Unit Heater Options Booklet
SCVO11 Cabinet Unit Heater s Booklet 3/18 s 22 114 28, 30, 31, 32, 33 126 29 23 129 40, 140 125 20, 50, 51 11 12 99 19, 119 18, 118 10 21 127 116 17 24 CAT00170F.dwg 2 TABLE OF CONTENTS OPTION NUMBER PAGE
More informationCabinet Unit Heaters Steam / Hot Water
11-160.4 February, 2005 Cabinet Unit Heaters Steam / Hot Water Model C MODEL IDENTIFICATION Table of Contents I. Model Identification... 3 Page Il. IIl. III. IV. Design Benefits A. Features and Benefits...
More informationREPLACEMENT PARTS MANUAL
REPLACEMENT PARTS MANUAL WALL-MOUNTED PACKAGE AIR CONDITIONER Models: W7A W8A WA General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual consists of
More informationCooling/Heat Pump Convertible Air Handlers
Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way
More informationAAF. Fan Coil XR 1-9. Last Manufactured: Replacement Parts List No Revision B 07/2001
Replacement Parts List No. 057113200 Revision B 07/2001 AAF Fan Coil XR 1-9 Last Manufactured: 1991 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com Table
More informationMcQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage G. Replacement Parts List No Revision C 09/2018
Replacement Parts List No. 70009200 Revision C 09/208 McQuay Self-Contained Variable and Constant Air Volume SWP 08-20 Vintage G This RPL is primarily intended for use with General Order (GO) numbers 835060-(
More informationModular Supply Make-Up Air Unit
Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features
More informationInstallation and Maintenance Manual IM 168-8
Installation and Maintenance Manual IM 168-8 HiLine Vertical Stacking Fan Coil Unit Group: Applied Air Systems Part Number: 910227749 Date: January 2018 Models FHSS 110 and FHSS 112 Table of Contents Nomenclature....
More informationREPLACEMENT PARTS MANUAL
REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGED AIR CONDITIONER W0AA-A W0AA-B W0AA-C W0AA-D W0AA-F WAA-A WAA-B WAA-C WAA-D WAA-E WAA-F Models: W0AADA W0AADB W0AADC WAADA WAADB WAADC Contents Description
More informationMP GS/GD 10 GAS. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)
MP GS/GD 0 GAS Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 36-7745 http://www.garland-group.com FORM # Moisture Plus Gas GS/GD0 (Rev 5) Page 2 FORM # Moisture Plus
More informationBlower-YEFB-020-3R-1maxVel
YEFB DUCTED UNIT GENERAL FEATURES Structure It is made of 1,0 mm thick galvanised steel. Despite this thickness, a special tool for production allowed to keep a good stiffness, in order to reduce the risk
More informationAIR HANDLER DESIGN WORK SHEET
AIR HANDLER DESIGN WORK SHEET JOB Project: Date Representative Unit Model No. of Units Unit Tag(s) UNIT CONSTRUCTION UNIT ARRANGEMENT: [ HORIZ VERT] [ INDOOR OUTDOOR] [ BASE MTD CEILING HUNG CURB MTD]
More informationManufacturer of HVAC Equipment Since ,000 sq. ft. on 16 acres. Colton, California USA
Manufacturer of HVAC Equipment Since 1916 400,000 sq. ft. on 16 acres Colton, California USA Visual factory Vertically integrated manufacturing BELT-DRIVEN AIR HANDLERS 800 12,000 CFM Horizontal Vertical
More informationSECTION CONVECTION HEATING AND COOLING UNITS
PART 1 GENERAL 1.01 SECTION INCLUDES A. Baseboard radiation. B. Finned tube radiation. C. Convectors. D. Unit heaters. E. Cabinet unit heaters. F. Fan-coil units. G. Unit ventilators. H. Blower-coil units.
More informationREPLACEMENT PARTS MANUAL
REPLACEMENT PARTS MANUAL WALL-MOUNTED PACKAGED AIR CONDITIONER HA-A HL-A Models: H6A-A H6L-A Description Page Cabinet Components HA-A, H6A-A Exploded View... Usage List HA-A... Usage List H6A-A... Cabinet
More informationMcQuay. Unit Ventilators Self-Contained UAED, UAEQ, UAER, UARQ, UERQ, UAZQ, UAZR, UAZS, UAZU, UAZV Designs D (4), E (5)
Replacement Parts List No. 700022700 Revision H 02/208 McQuay Unit Ventilators Self-Contained UAED, UAEQ, UAER, UARQ, UERQ, UAZQ, UAZR, UAZS, UAZU, UAZV 024-054 Designs D (4), E (5) To find your Daikin
More informationK*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*
TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling
More informationMini Duct Heating and Air Conditioning Indoor Air Quality Systems. July Featuring: Also Including: Lo-Velocity Systems JH Fancoils
Mini Duct Heating and Air Conditioning Indoor Air Quality Systems July 2008 Parts List Featuring: TM Also Including: Lo-Velocity Systems JH Fancoils Minimum Invoice Amount of $25 Net in Effect ESP 100.02b
More informationINSTALLATION AND OPERATION MANUAL ANALOG ELECTRONIC CONTROLS VAV TERMINAL UNITS
INSTALLATION AND OPERATION MANUAL ANALOG ELECTRONIC CONTROLS VAV TERMINAL UNITS CTE-51 Series Thermostats: The CTE-51 series thermostats are designed to be used with the CSP-52 controller actuator. CTE-51
More informationModular Multi-position Air Handlers
Modular Multi-position Air Handlers Black Epoxy Coil TAM4A0A18S11ED TAM4A0A24S21ED TAM4A0A30S21ED TAM4A0A36S31ED TAM4A0B42S31ED TAM4A0C48S41ED TAM4A0C60S51ED Standard Coil TAM4A0A18S11SD TAM4A0A24S21SD
More informationTHE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features
THE WALL-MOUNT ONE TON AIR CONDITIONER W2AAA 2,000 Btuh.00 EER Right Side Control Panel 60Hz Green Refrigerant R-4A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating
More informationHiLine Vertical Stacking Fan Coils. Type FHSS and FHSK. Catalog
HiLine Vertical Stacking Fan Coils Type FHSS and FHSK Catalog 770-17 Table of Contents Introduction.... 3 Daikin Applied HiLine Fan-Coil Units...3 Nomenclature...3 Introduction.... 4 Low CFM design (300
More informationCOS-101 NON SELF FLUSHING COMBI REPLACEMENT PARTS LIST
COS-101 NON SELF FLUSHING COMBI REPLACEMENT PARTS LIST EFFECTIVE FEBRUARY 16, 2012 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified
More informationR7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units
TECHNICAL SPECIFICATIONS R7DA Series 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units 5.4 ISMRE Commercial System 81% Steady State Efficiency Standard Features Fits Pre-Existing Curbs High-Efficiency Low
More informationAAF Herman Nelson. Classmate Conventional Unit Ventilators. AH AV Vintage C
Replacement Parts List No. 0575800 Revision R 0/206 AAF Herman Nelson Classmate Conventional Unit Ventilators AH 00-008 AV 00-006 Vintage C UAHB, UAHF, UAHR, UAHV 07-20 UAVB, UAVR, UAVS, UAVV 07-5 Design
More informationInstallation & Maintenance Data IM Contents
Installation & Maintenance Data IM 254-4 Group: Fan Coil Part Number: 107133000 Date: June 1999 SeasonMaker HiLine Fan-coil Units Type KZZ Contents Inspection..................................... 2 Riser
More informationEffective october 14, 2014
COS-101 & COS-101S COMBI OVEN STEAMER REPLACEMENT PARTS LIST Effective october 14, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items
More informationCWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH
CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH 233 CWA2 NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool with Electric Heat Multiposition Fan Coil Nominal
More informationAll side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.
All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing
More informationHydronic Heating Fan Coils Radiant ceiling systems Water Source Heat Pumps Rittling Cabinet Unit Heaters
Hydronic Heating Fan Coils Radiant ceiling systems Water Source Heat Pumps Rittling Cabinet Unit Heaters Catalog Zehnder decorative radiators Heating and cooling ceiling systems Comfortable indoor ventilation
More informationTechnical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS
Technical Guide SPLIT-SYSTEM EVAPORATOR BLOWERS 7-1/2 and 10 NOMINAL TONS LA090 & LA120 DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes
More information27" GAS DRYER MODELS: WGD95HEDW0 (White) WGD95HEDC0 (Chrome Shadow) 05/13/ Whirlpool Corporation Part No. W Rev.
27" GAS DRYER MODELS: WGD95HEDW0 (White) WGD95HEDC0 (Chrome Shadow) 05/13/2014 2014 Whirlpool Corporation Part W10710285 Rev. A TOP AND CONSOLE PARTS 05/13/2014 2 Part W10710285 Rev. A TOP AND CONSOLE
More informationHiLine Vertical Stacking Fan-coil Units
Catalog C: 770-12 HiLine Vertical Stacking Fan-coil Units Type HSS & KZZ ARI 440 CUL Listed McQuay SeasonMaker HiLine fan-coil units The McQuay HiLine SeasonMaker fan-coil air conditioning units are designed
More information