McQuay. Aircon Air Cooled Condenser. AMB, APB AMD, APD Vintage A. Last Manufacture: 1978
|
|
- Britney Harmon
- 5 years ago
- Views:
Transcription
1 Replacement Parts List No Revision C 10/2017 McQuay Aircon Air Cooled Condenser AMB, APB AMD, APD Vintage A Last Manufacture: 1978 To find your Daikin Applied parts distributor, call or visit
2 Contents Parts List Revision History... 3 Nomenclature Serial Number... 4 Model Number... 4 Fan Components AMB, APB AMD, APD Critical Parts List... CPL1 Air Cooled Condenser; AMB,APB ; AMD,APD Rev. C 10/17 RPL / Page 2
3 Parts List Revision History Revision Date Description A 09/00 Revised to electronic format. B 12/15 Rebrand to Daikin. Page 4- Add serial and model number. Page 6- Change 20 fan p/n to Add capacitor p/n CPL1- Add critical parts list. C 10/17 Page 4- Corrected descriptions for Code 02. (Example: was 20,000 Tons, should be 20 Tons.) Daikin Applied,13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN (763) Air Cooled Condenser; AMB,APB ; AMD,APD Rev. C 10/17 RPL / Page 3
4 Nomenclature Serial Number 7 6A Factory 7= Auburn, NY Engineering Revision Year and Month of Manufacture: Year Month 6= 1996 A= Jan. G= Jul. 7= 1997 B= Feb. H= Aug. 8= 1998 C= Mar. J= Sep. 9= 1999 D= Apr. E= May F= Jun. K= Oct. L= Nov. M= Dec. Serial Number Model Number A P D 020 A V Air Cooled Condenser Propeller Fan M= Propeller (Old Model) P= Propeller (New Model) Drive Type B= Belt Drive D= Direct Drive Airflow H= Horizontal V= Vertical Design Vintage Nominal Capacity (Tons) Code 01= Unit Type AMB= Aircon Air Cooled Condenser Belt Drive APB= Aircon Air Cooled Condenser Belt Drive AMD= Aircon Air Cooled Condenser Direct Drive APD= Aircon Air Cooled Condenser Direct Drive Code 02= Unit Size/Vintage Belt Drive 020A= 20 Tons 070A= 70 Tons 025A= 25 Tons 075A= 75 Tons 030A= 30 Tons 080A= 80 Tons 035A= 35 Tons 085A= 85 Tons 040A= 40 Tons 090A= 90 Tons 045A= 45 Tons 100A= 100 Tons 050A= 50 Tons 110A= 110 Tons 055A= 55 Tons 120A= 120 Tons 060A= 60 Tons 130A= 130 Tons 065A= 65 Tons 140A= 140 Tons Model Number Code 02= Unit Size/Vintage (Continued) Direct Drive 008A= 8 Tons 010A= 10 Tons 015A= 15 Tons 020A= 20 Tons 025A= 25 Tons 030A= 30 Tons Code 03= Air Discharge H= Horizontal Air Discharge V= Vertical Air Discharge Code 04= Unit Voltage 12= 208/60/3 27= 460/60/3 29= 230/60/3 33= /60/1 Air Cooled Condenser; AMB,APB ; AMD,APD Rev. C 10/17 RPL / Page 4
5 Fan Components AMB, APB Description Part Number AMB020 / APB020A AMB025 / APB025A AMB0300 / APB030A AMB035 / APB035A AMB040 / APB040A AMD45 / APD045A AMD50 / APD050A AMD55 / APD055A AMD60 / APD060A AMD65 / APD065A AMD70 / APD070A AMD75 / APD075A AMD80 / APD080A AMD85 / APD085A AMD90 / APD090A AMD100 / APD065A AMD110 / APD065A AMD120 / APD065A AMD130 / APD065A AMD140 / APD065A Condenser Fan, Condenser Fan, Condenser Motor, 1/2HP, 208/60/ Condenser Motor, 1/2HP, /60/ Condenser Motor, 1HP, /60/ Condenser Motor, 1HP, /60/ Condenser Motor, 1-1/2HP, 208/60/ Condenser Motor, 1-1/2HP, /60/ Condenser Motor, 2HP, 208/60/ Condenser Motor, 2HP, /60/ Condenser Motor, 3HP, 208/60/ Condenser Motor, 3HP, /60/ Condenser Motor, 5HP, 208/60/ Condenser Motor, 5HP, /60/ Capacitor, 8MFD, 370V Capacitor, 20MFD, 440V Rain Slinger Bearing Kit W/spacers & bolts * Bearing, Pillow Block Contactor, 220V, Fantrol only Contactor, 220V, Fantrol only Contactor, 220V, Fantrol only Pressure Operator, 2 Stroke- R Pressure Operator, 2 Stroke- R Thermostat, Fantrol only Motor, Dampertrol * Bearing Kit replaces bearing Mandrel now obsolete. Air Cooled Condenser; AMB,APB ; AMD,APD Rev. C 10/17 RPL / Page 5
6 Fan Components AMD, APD Description Part Number AMD8 / APD008A AMD10 / APD010A AMD15 / APD015A AMD20 / APD020A AMD25 / APD025A AMD30 / APD030A Condenser Fan, Condenser Fan, Fan Guard, Fan Guard, Condenser Motor, 3/4HP, /60/ Condenser Motor, 3/4HP, 460/60/ Condenser Motor, 3/4HP, /60/ Capacitor, 8MFD, 370V Motor Kit Motor Mount Motor Mount Rain Slinger Fantrol Contactor, V Thermostat Fantrol Pressure Operator, 1 stroke- R Pressure Operator, 1 stroke- R Air Cooled Condenser; AMB,APB ; AMD,APD Rev. C 10/17 RPL / Page 6
7 Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! McQuay Aircon Air Cooled Condenser AMB, APB AMD, APD Vintage A Critical Components Model Unit Size Voltage Part Number Condenser Fan Motor- Belt Drive Motor, 1/2HP AMB, APB /60/ Motor, 1/2HP AMB, APB /460/60/ Motor, 1HP AMB, APB /60/ Motor, 1HP AMB, APB /460/60/ Motor, 1.5HP AMB, APB 025, 050, /60/ Motor, 1.5HP AMB, APB 025, 050, /460/60/ Motor, 2HP AMB, APB , 060, 080, /60/ Motor, 2HP AMB, APB , 060, 080, /460/60/ Motor, 3HP AMB, APB 055, , 100, /60/ Motor, 3HP AMB, APB 055, , 100, /460/60/ Motor, 5HP AMB, APB /60/ Motor, 5HP AMB, APB /460/60/ Condenser Fan Motor- Direct Drive Motor, 3/4HP AMD, APD /60/ Motor, 3/4HP AMD, APD /60/ Motor, 3/4HP AMD, APD /60/ Condenser Fan- Belt Drive Fan, 4- Blade, 42 AMB, APB N/A Fan, 4- Blade, 54 AMB, APB N/A Condenser Fan- Direct Drive Fan, 5- Blade, 20 AMD, APD N/A Fan, 4- Blade, 24 AMD, APD N/A Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To or Call PARTS Rev. C 10/2017 CPL Page 1 of 1
McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1)
Replacement Parts List No. 110509900 Revision E 07/2016 McQuay Incremental PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1) To find your Daikin Applied
More informationDaikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017
Replacement Parts List No. 700028400 Revision A 07/207 Daikin McQuay Incremental PKEI, PKES, PKHS 07-09 Design 2 To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com
More informationMcQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017
Replacement Parts List No. 700016700 Revision A 07/2017 McQuay Console Water Source Heat Pump WWDU 07-15 Design A Last Manufactured: 2005 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationMcQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018
Replacement Parts List No. 70006800 Revision D 03/208 McQuay Enfinity Vertical Water Source Heat Pump WFCV, WFCW 007-02 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit
More informationMcQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988
Replacement Parts List No. 055204700 Revision D 01/2017 McQuay Climate Control Horizontal Water Source Heat Pump CC, CG, CW, UC, UG, UW 610-630 Vintages E, F, G Last Manufactured: 1988 To find your Daikin
More informationMcQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998
Replacement Parts List No. 04765700 Revision E 04/08 McQuay Roofpak Roof Mounted Air Handler Draw- Through RDS Size: 900 Vintage: B Last Manufactured: 998 To find your Daikin Applied parts distributor,
More informationDaikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)
Replacement Parts List No. 700018800 Revision C 08/2012 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design D (4) To find your Daikin Applied parts distributor,
More informationMcQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1)
Replacement Parts List No. 110510700 Revision G 02/2015 McQuay Concealed Ceiling Water Source Heat Pump WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1) WCAS, WCDA, WCDL, WCDS, WCMS 030 Design
More informationDaikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015
Replacement Parts List No. 700027600 Revision D 02/2015 Daikin McQuay Packaged Terminal Air Conditioner PGAN 007, 009, 012, 015 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationMcQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993
Replacement Parts List No. 055237600 Revision D 08/2017 McQuay Vertical Water Source Heat Pump FCV, FCG, FCW 036, 042 Vintage A Last Manufactured: 1993 To find your Daikin Applied parts distributor, call
More informationMcQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995
Replacement Parts List No. 055236000 Revision B 06/2015 McQuay Ceiling Concealed Horizontal Water Source Heat Pump CCH, CCG, CCW 048, 060 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts
More informationMcQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000
Replacement s List No. 5709900 Revision N 0/205 McQuay Incremental MQE 007, 009, 02, 05, 06 MQR 007, 009, 02, 05 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call -800-377-2787
More informationMcQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993
Replacement s List No. 55209100 Revision E 10/2015 McQuay Console Water Source Heat Pump WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A Last Manufactured: 1993 To find your Daikin Applied parts distributor,
More informationAAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016
Replacement Parts List No. 057117300 Revision D 08/2016 AAF Water Source Heat Pump Ceiling Mounted CCW 019-060 Vintage E Last Manufactured: 1999 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationMcQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991
Replacement Parts List No. 055203500 Revision G 05/206 McQuay Climate Control Singer Incremental ES, RS, S 06, 09,, 4 Vintage B Last Manufactured: 99 To find your Daikin Applied parts distributor, call
More informationMcQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994
Replacement Parts List No. 05708900 Revision C 06/205 McQuay Incremental Packaged Terminal Air Conditioner MQT 06-4 Vintage B Last Manufactured: 994 To find your Daikin Applied parts distributor, call
More informationMcQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012
Replacement s List No. 700024500 New 07/2012 McQuay Screw Chiller Water Cooled WHS 155-200 Vintage A Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit
More informationMcQuay. Large Vertical Water Source Heat Pump. LGP, LHP, LWP Vintage C. Last Manufactured: 1994
Replacement Parts List 0570900 Revision F 09/06 McQuay Large Vertical Water Source Heat Pump LGP, LHP, LWP 07-7 Vintage C Last Manufactured: 994 To find your Daikin Applied parts distributor, call -800-77-787
More informationMcQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017
Replacement s List 055208000 Revision E 08/207 McQuay Incremental MQS 007-05 Vintages A 02-05 Vintage B Last Manufactured: 993 To find your Daikin Applied parts distributor, call -800-377-2787 or visit
More informationMcQuay. Commercial Unitary Rooftop. CUR Vintage G. Last Manufactured: Replacement Parts List No Revision A 11/2016
Replacement Parts List No. 057102700 Revision A 11/2016 McQuay Commercial Unitary Rooftop CUR 075-150 Vintage G Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationMcQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007
Replacement Parts List No. 700002400 Revision D 11/2009 McQuay Acson Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR 20-50 Last Manufactured: 2007 To find your Daikin Applied
More informationMcQuay. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. WCDD, WCDE, WCMG Design A (1) WCDD, WCDE Design B (2)
Replacement Parts List No. 057117200 Revision G 08/2016 McQuay Water Source Heat Pump Ceiling Mounted CCW 019-060 Vintage E WCDD, WCDE, WCMG 019-060 Design A (1) WCDD, WCDE 019-060 Design B (2) To find
More informationDaikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 007, 009, 012 Design 1. Replacement Parts List No Revision M 11/2017
Replacement Parts List No. 700013000 Revision M 11/2017 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationDaikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision O 11/2017
Replacement Parts List No. 700013100 Revision O 11/2017 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationDaikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision R 11/2018
Replacement Parts List No. 700013100 Revision R 11/2018 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationAir Cooled Scroll Compressor Condensing Unit
Replacement Parts List No. 70000900 Rev. B 2/08 Air Cooled Scroll Compressor Condensing Unit ACZ Sizes: 00-039 Vintage: B R22, R407C Contents Contents... 2 Parts List Revision History... 3 Nomenclature
More informationDaikin. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 2. Replacement Parts List No New 11/2017
Replacement Parts List No. 700053300 New 11/2017 Daikin Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit
More informationDaikin. Self-Contained Unit Ventilator. UAEQ 036, 044, 054 Design H (8) Replacement Parts List No New 11/2017
Replacement Parts List No. 70005300 New /207 Daikin Self-Contained Unit Ventilator UAEQ 036, 044, 054 Design H (8) To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com
More informationAAF. Fan Coil XR 1-9. Last Manufactured: Replacement Parts List No Revision B 07/2001
Replacement Parts List No. 057113200 Revision B 07/2001 AAF Fan Coil XR 1-9 Last Manufactured: 1991 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com Table
More informationDaikin Altherma Selection Report
Daikin Altherma Selection Report Produced on 20.10.2014 with Daikin Altherma Simulator V4.4.7 - database Central 9.7.9 Project name Energa Sistemi Reference Airabela Client name Energa Sistemi Revision
More informationClimate Control Singer. Incremental Comfort Systems. KS, EKS Vintage B. Last Manufactured: 1982
Replacement s List No. 055202900 Revision A 11/1999 Climate Control Singer Incremental Comfort Systems KS, EKS 07-15 Vintage B Last Manufactured: 1982 To find your Daikin Applied parts distributor, call
More informationPTC Creo 2.0 Hardware Support Hewlett Packard
PTC Creo 2.0 Hardware Support Hewlett Packard Last updated: December 11, 2017 The Desktop Virtualization Environment Support HP table displays at the end of this document, after the standard Creo certification
More informationMcQuay. Self-Contained Unit Ventilator. UAZQ, UAZR, UAZU Design G (7) Replacement Parts List No Revision D 08/2018
Replacement Parts List No. 700051500 Revision D 08/2018 McQuay Self-Contained Unit Ventilator UAZQ, UAZR, UAZU 024-054 Design G (7) To find your Daikin Applied parts distributor, call 1-800-377-2787 or
More informationSpecial Topics on Residential HVAC
Special Topics on Residential HVAC by Armin Rudd USDOE Building America Program for EEBA Conference 2002 Phoenix, Arizona 10 October 2002 Page 1 of 25 Two Main Topics: 1. Cyclical trade-offs between building
More informationMcQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage A. Replacement Parts List No Revision E 04/2016
Replacement Parts List No. 7000900 Revision E 04/06 McQuay Templifier Scroll Compressor Water Heater TGZ 040-90 Vintage A To find your Daikin Applied parts distributor, call -800-77-787 or visit www.daikinapplied.com
More informationMcQuay. Seasonmaker ThinLine Horizontal Fan Coil. TSH, TSC Vintage F. FTSH, FTSC Designs A(1), B(2) Last Manufactured: 2008
Replacement Parts List No. 055237900 Revision R 12/2017 McQuay Seasonmaker ThinLine Horizontal Fan Coil TSH, TSC 031-121 Vintage F FTSH, FTSC 03-12 Designs A(1), B(2) Last Manufactured: 2008 To find your
More informationMASTER PLAN KICK-OFF Open House #1A, April 28, 2015
"The beginning is the most important part of the work." Plato, The Republic MASTER PLAN KICK-OFF Open House #1A, April 28, 2015 YOUR CAMPUS PLANNING TEAM Campus Planners Landscape Architects Urban Designers
More informationEquipment ATA 12 April 2016
05-00-01 Time limits and Maintenance Frequencies Various JUN 14 1 25-00-01 Charging Head Mk 2 & Accessories WKA26592 WKA26592A 25-60-15 Submersion Actuator K38215 58178-001 AUG 92 JAN 15 Initial Issue
More informationDaikin McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage B. Replacement Parts List No Revision F 11/2017
Replacement Parts List No. 7000800 Revision F /07 Daikin McQuay Templifier Scroll Compressor Water Heater TGZ 040-90 Vintage B To find your Daikin Applied parts distributor, call -800-77-787 or visit www.daikinapplied.com
More informationWLAC Facilities Committee Meeting. September 18, 2017
Campus Program Report WLAC Facilities Committee Meeting September 18, 2017 Page 1 DSA approved the plans on May 15, 2017. Notice to Proceed was issued June 8, 2017 and the project remains on schedule for
More informationAIRCRAFT TECHNICAL SPECIFICATIONS Dornier / MSN 3079
AIRCRAFT TECHNICAL SPECIFICATIONS Dornier 328-100 / MSN 3079 GENERAL DESCRIPTION Aircraft Type / Model: Dornier 328-100 Operator: SATENA Serial Number: 3079 Previous Operator(s): None Date of Manufacture:
More informationDehumidification: Energy Efficiency Comparisons
Fourth Annual Energy Management Workshop Cocoa, Florida February 10-11, 2003 Dehumidification: Energy Efficiency Comparisons Michael K. West, Ph.D., P.E. Building Systems Scientist Advantek Consulting,
More informationBoulder County Comprehensive Drilling Plan Surface Owner Meeting. Thursday, Oct. 19, 2017
Boulder County Comprehensive Drilling Plan Surface Owner Meeting Thursday, Oct. 19, 2017 Contact Crestone Crestone Peak Resources Quick Facts www.crestonepeakresources.com cdpboulder@crestonepr.com (720)
More informationThe Ed Roberts Campus Berkeley, CA
The Ed Roberts Campus Berkeley, CA Anderson Clemenceau Mechanical Option Penn State A.E. Senior Thesis April 14, 2015 Leddy Maytum Stacy Architects, Photo by Tim Griffith ASHRAE Climate Zone 3C 99.6% Heating
More informationEngineers and Contractors - Innovative Technologies to Achieve Highest GeoExchange System Efficiencies for Commercial Projects
Engineers and Contractors - Innovative Technologies to Achieve Highest GeoExchange System Efficiencies for Commercial Projects Presented by: Warren (Trey) Austin, PE, CEM, CGD, LEED-AP Geo-Energy Services,
More informationPractical and Effective Approaches to Residential Ventilation for Production Builders
Practical and Effective Approaches to Residential Ventilation for Production Builders by Armin Rudd USDOE Building America Program for Affordable Comfort Conference 2002 Cincinnati, Ohio 18 April 2002
More informationBoulder County Comprehensive Drilling Plan Surface Owner Meeting. Thursday, Nov. 2, 2017
Boulder County Comprehensive Drilling Plan Surface Owner Meeting Thursday, Nov. 2, 2017 Contact Crestone Crestone Peak Resources Quick Facts www.crestonepeakresources.com cdpboulder@crestonepr.com (720)
More informationMcQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E
Replacement Parts List No. 700008400 Revision V 04/2018 McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 030, 035, 040, 050 Vintage A, E To find your Daikin Applied parts distributor,
More informationMillburn, NJ, Residential Area Stormwater Analyses
Base Conditions Parameter Files: Millburn, NJ, Residential Area Stormwater Analyses R. Pitt March 12, 2012 1 Millburn Typical Medium Density Home: Source Area Area (acres) Description Roofs 1 0.08 Pitch
More informationMcQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 020, 025 Vintage E. Replacement Parts List No Revision J 02/2018
Replacement Parts List No. 700014900 Revision J 02/2018 McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 020, 025 Vintage E To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationAuburn University Basketball Arena:
Auburn University Basketball Arena: How Building Data Analytics Achieved Energy and O&M Savings While Improving Comfort and Sustainability Eric Moore, PE, CEM, Auburn University Hadas Webb, CEM, Cimetrics
More informationSivu 2/8 Rate data Description Suomi Shut off times total 0.0 h/day Weekends with shut off times yes Daytime rate of heat pump Time for daytime rate 5
Sivu 1/8 Design of a heat pump heating system with Aquarea Designer Project: Suomi 1 Date: Created by:?, (no data provided), (no data provided) Phone: (no data provided) Email: (no data provided) Building
More informationLEASEHOLD YEARLY PROPERTY SCHEDULE
This Yearly Property Schedule is simply a guide to managing your Facility. Please reallocate duties as they suit the management of your Facility, however, note that all tasks should be listed on the schedule
More informationWestinghouse UK AP1000 GENERIC DESIGN ASSESSMENT Resolution Plan for GI-AP1000-IH-01 Internal Fire Safety Case Substantiation.
Westinghouse UK AP1000 GENERIC DESIGN ASSESSMENT Internal Fire Safety Case Substantiation MAIN ASSESSMENT AREA RELATED ASSESSMENT AREA(S) RESOLUTION PLAN REVISION GDA ISSUE REVISION Internal Hazards Civil
More informationWater Heater Innovations Marathon Water Heater Limited Warranty Policies & Procedures
INTRODUCTION Water Heater Innovations (WHI) offers a Limited Warranty against defects in materials and workmanship on all its products. Our warranty program was developed to assure those who buy and sell
More informationCURTISS-WRIGHT CONTROLS INTEGRATED SENSING (CAGE CODE: 03972).
Overhaul Manual REVISION STATUS, as of MAY 18, 2016 No changes to CMM document revisions for Curtiss-Wright Cage Code: 03972 - have occurred since the last revision of this CMM Revision Status List was
More informationFree cooling on RTAF Chiller. Integrated option
Free cooling on RTAF Chiller Integrated option Water based free cooling principle. Use full aluminum (car radiator based) flat channel dry cooler exchangers. Modulate 3 way to reach required free cooling
More informationUNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY
Revision No.: 3 Page 1 of 6 I. PURPOSE This policy establishes the steps required for performing the monthly fixed systems inspections and the semi-annual systems testing. Fixed systems include; wet chemical
More informationSolar Heating Solutions
Solar Heating Solutions 30 25 TEMPERATURE GUIDE Month Unheated Heated (Solar) Jan 24.0 28.8 Feb 23.5 28.2 Mar 22.8 27.4 Apr 19.0 25.3 May 15.1 19.5 20 15 Heated (Solar) Unheated Jun 12.3 16.2 Jul 11.9
More informationRemodeling Market. Kermit Baker. Remodeling Futures Conference November 9, Harvard University JOINT CENTER FOR HOUSING STUDIES
Remodeling Market Trends and Update Kermit Baker Remodeling Futures Conference November 9, 2010 Remodeling Market Trends 1. Remodeling spending saw significant decline during recession; greatest fall-off
More informationCROWN YEARLY PROPERTY SCHEDULE
This Yearly Property Schedule is simply a guide to managing your Facility. Please reallocate duties as they suit the management of your Facility, however, note that all tasks should be listed on the schedule
More informationMcQuay. Roofpak Condensing Unit Medium Cabinet, Standalone. RCS Tons Vintage C Code 12= 1A, 2A. Valid for units built 06/2010 & Earlier
eplacement Parts List No. 000000 evision F 09/06 McQuay oofpak Condensing Unit Medium Cabinet, Standalone CS 050-05 Tons Vintage C Code = A, A Valid f units built 06/00 & Earlier To find your Daikin Applied
More informationIn partnership with: Harbor Corridor Plan Bali Hi Mobile Home Park July 24, 2013
In partnership with: Harbor Corridor Plan Bali Hi Mobile Home Park July 24, 2013 Project Intro 2-miles of Harbor Boulevard Westminster/17 th Street to just north of Edinger Avenue Many people use the corridor
More informationSOUTHEND CARELINE ANNUAL REPORT
SOUTHEND CARELINE ANNUAL REPORT 2015-2016 Meet some of the CareLine Team Southend Careline TSA accredited 2015-2016 Southend Careline offers reassurance and peace of mind to our service users their family
More informationWLAC Facilities Committee Meeting. May 15, 2017
Campus Program Report WLAC Facilities Committee Meeting May 15, 2017 Page 1 DSA completed the initial review June 24, 2016 and the Design Builder is proceeding through the back check process. DSA reports
More informationRt 29 Solutions Hydraulic Planning Advisory Panel. September 14, 2017
Hydraulic Planning Advisory Panel September 14, 2017 Agenda Item 1: Introductions Hydraulic Planning Advisory Panel members Technical Team members 2 Agenda item 2: Public Interaction and Feedback Live
More informationSOLAR HOT WATER AND HEAT PUMP BOOSTER ENERGY CALCULATION METHODOLOGY
SOLAR HOT WATER AND HEAT PUMP BOOSTER ENERGY CALCULATION METHODOLOGY PART A: CALCULATION METHODOLOGY FOR SOLAR WATER HEATERS AND HEAT PUMP WATER HEATERS WITH A VOLUMETRIC CAPACITY OF UP TO AND INCLUDING
More informationKELLYVILLE LIONS CALENDAR 2016 to 2017
01-Nov-16 02-Nov-16 03-Nov-16 KELLYVILLE LIONS CALENDAR 2016 to 2017 Meetings BBQ'S Other Birthdays No meeting due to Calcutta MELBOURNE CUP 04-Nov-16 05-Nov-16 Elizabeth Sadler 06-Nov-16 07-Nov-16 John
More informationMEASURED PERFORMANCE DATA FOR
MEASURED PERFORMANCE DATA FOR HOUSE #4 INVERNESS GARDENS MILLER HOMES FEBRUARY 2013 Submitted to: NYSERDA 17 Columbia Circle Albany, NY 12203 Submitted by: HOMEPIC Team CDH Energy Corp. PO Box 641 Cazenovia,
More informationBetter Buildings By Design 2013 Building the Renewable Energy Ready Home Solar Thermal Lessons Learned and Results
Image Courtesy of Harvestar Better Buildings By Design 2013 Building the Renewable Energy Ready Home Solar Thermal Lessons Learned and Results Doug Merrill, Sunward Systems Doug Merrill 20 + years of manufacturing
More informationHigh Tunnel Winter Greens Production
Planting Schedules for High Tunnel Winter Greens Production Liz Maynard and Erin Bluhm Department of Horticulture and Landscape Architecture Jan. 4, 2018 Illiana Vegetable Growers Symposium Schererville,
More informationHot Water a Hot Commodity Better Buildings by Design, February 2012 Burlington, VT
Hot Water a Hot Commodity Better Buildings by Design, February 2012 Burlington, VT Gary Klein Affiliated International Management, LLC 916 549 7080 gary@aim4sustainability.com Gary Klein, 2012 Efficiency
More informationIES Whole-Building Energy Model Baseline Energy Model Input/ Output Report. East Liberty Presbyterian Church East Liberty Presbyterian Church
IES Whole-Building Energy Model Baseline Energy Model Input/ Output Report East Liberty Presbyterian Church 14 009 For: By: East Liberty Presbyterian Church Jeffery Ison, James Construction Date: October
More informationContinuous Commissioning: A Valuable Partner to Retrofit Projects
Continuous Commissioning: A Valuable Partner to Retrofit Projects Yeqiao Zhu Aamer Athar Kenneth Banks Ph.D. PE, CEM PE, CEM Energy Systems Laboratory Sempra Energy Solutions Sempra Energy Solutions Charles
More informationAustralian Indoor Flue Installation Instructions Vertical Termination Flue Kits for Universal H-Series (Forced-Draft) Heaters
Australian Indoor Flue Installation Instructions Vertical Termination Flue Kits for Universal H-Series (Forced-Draft) Heaters IMPORTANT NOTES:. This kit is intended to be used only with Australian Hayward
More informationPAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)
www.source1parts.com HVAC SERVICE PARTS PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A) Supersedes:035-21137-001 Rev. E (1107) 035-21137-001 Rev. F (0611) 1 of 8 CONDENSER ROOF (SEE
More informationCOMPONENT MAINTENANCE MANUAL INDEX. Aug 2013
Cage Code: 96182 COMPONENT MAINTENANCE MANUAL INDEX Aug 2013 This Index provides the latest status of publications supplied by: Eaton Corporation Fluid & Electrical Distribution Division, 3184 Pullman
More informationTime-Based Scheduling of Residential Ventilation
Time-Based Scheduling of Residential Ventilation by Armin Rudd USDOE Building America Program for EEBA Conference 2000 Building for Peak Performance Denver, Colorado 26 October 2000 Climate Specific Design
More informationFacilities Planning & Construction Report nd Quarter Ending December 31, 2016
Facilities Planning & Construction Report 2016 17 2 nd Quarter Ending December 31, 2016 Overview District SRID Spending (MG100) Summary By College By Site District Program Overview Construction Design
More informationTransfer Station Recycling Update SWANA Technical Session-Waste Diversion 4 2/24/2017 2/28/2017
Transfer Station Recycling Update SWANA Technical Session-Waste Diversion 4 2/24/2017 1 Todays Outline Roadmap to 70% A look back on how we started.. Vashon yard & food waste Styrofoam & plastic film Resource
More informationCopyright 2003 IBACOS, Inc. All rights reserved.
Domestic Hot Water Research Research conducted by Bill Rittelmann Presented by Duncan Prahl Partners for High Performance Homes Meeting Westminster, CO, June 23, 2005 DHW Systems: Current Technologies
More informationCork County Energy Agency
Cork County Energy Agency Energy Audit Midleton Area Office December 2009 Table of Contents 1. Introduction...1 2. Site description...2 3. On site energy use...3 3.1 Energy management...3 3.2 Breakdown
More informationMake gelato and more delicious things right in front of your customers Let the show begin!
Make gelato and more delicious things right in front of your customers Let the show begin! Three simple ideas for winning over your current and future customers. 1 2 3 Gelato Make a few flavors always
More informationLOW IMPACT DEVELOPMENT GUIDANCE MANUAL AND LID WORKING GROUP ACTIVITIES. Powerpoint Templates. MS4 Statewide Stormwater Summit June 18, 2013
LOW IMPACT DEVELOPMENT GUIDANCE MANUAL AND LID WORKING GROUP ACTIVITIES MS4 Statewide Stormwater Summit June 18, 2013 Powerpoint Templates Evan Canfield, Ph.D, P.E. Pima County Regional Flood Control Outline
More informationMP GS/GD 10 GAS. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)
MP GS/GD 0 GAS Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 36-7745 http://www.garland-group.com FORM # Moisture Plus Gas GS/GD0 (Rev 5) Page 2 FORM # Moisture Plus
More informationVillage of Glenview Appearance Commission
Village of Glenview Appearance Commission https://drive.google.com/file/d/0bwqoselr903slw1ovvdnd2nlzws/edit?usp=sharing STAFF REPORT August 13, 2014 TO: Chairman and Appearance Commissioners FROM: Community
More informationDISTRICT HEATING SCHEME FEASIBILITY STUDY FRANKTON FLATS QUEENSTOWN
DISTRICT HEATING SCHEME FEASIBILITY STUDY FRANKTON FLATS QUEENSTOWN 2010 ALPINE AQUALAND EVENTS CENTRE QUEENSTOWN AIRPORT LAKES DISTRICT HOSPITAL Prepared by building services design engineers 2 District
More informationMARVAIR CLASSIC HEAT PUMPS MODELS AVP HP EXPLODED VIEW PARTS ID
EXTERIOR SHEET METAL (OUTER PANELS) 1 Panel, Back (Galvanized) M/05039SP M/05034SP M/05034SP 2 Door, Front Top 02976SP 02937SP 02937SP 3 4 Door, Front Bottom w/slots, Damper 1,2 (shown) M/06753-XXSP M/06752-XXSP
More informationEL PALOMAR 19 UNITS + HOUSE
EL PALOMAR 19 UNITS + HOUSE 204 & 206 N. SUNSHINE BLVD., ELOY, AZ 85131 EL PALOMAR NOW HAS: 1. Brand new electrical with an 800 amp underground main feed and 4 sub-panels (This alone is a major additional
More informationIndex. Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8. Fire Risk Assessments 9
Index Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8 Fire Risk Assessments 9 Fire Alarm Systems 10-20 Locations 10 Servicing 11 12 Activations 13 14 Weekly Checks
More informationDesigning and Operating an Energy Efficient Foodservice Facility March 12, 2014 Winnipeg, MB
Designing and Operating an Energy Efficient Foodservice Facility March 12, 2014 Winnipeg, MB Don Fisher, P. Eng. Fisher Consultants PG&E Food Service Technology Center 925-866-5770 dfisher@fishnick.com
More informationOn Balance: Heat Rejection Control a Packaged Solution
On Balance: Heat Rejection Control a Packaged Solution Echelon Americas Channel Partner Conference March 11, 2005 Presented by Doug Scott VaCom Technologies La Verne, California Opportunity An integrated
More informationUNDERCOUNTERS, WORKTOPS AND FOOD PREP TABLES REFRIGERATORS AND FREEZERS PARTS BREAKDOWNS
FAGOR INDUSTRIAL UNDERCOUNTERS, WORKTOPS AND FOOD PREP TABLES REFRIGERATORS AND FREEZERS PARTS BREAKDOWNS For Customer Service: Call 1 866 GO FAGOR www.fagorcommercial.com P. 1 1 PARTS BREAKDOWNS 2 For
More informationRegional Open Space Conservation Plan. Regional Staff Committee January 18, 2018
Regional Open Space Conservation Plan Regional Staff Committee January 18, 2018 Schedule We are here Task 1 - Stakeholder Input & Work Plan Dev. v z 2016 2017 2018 Oct Nov Dec Jan Feb Mar Apr May Jun Jul
More informationGrain Handling, Drying and Storage Management
Grain Handling, Drying and Storage Management Michael J. Buschermohle Biosystems Engineering and Soil Science Grain Handling, Drying and Storage Management What Affects Grain Quality Grain Handling Grain
More informationannouncements 4/10/08
Psychrometrics & Design Strategies ARCH 331/431 Spring 2008 Lecture 4 announcements 4/10/08 course website: http://courses.washington.edu/arch3431/index.shtml Course materials (readings, assignments, lectures,
More informationLaboratory Evaluation of Hybrid and Advanced Water Heaters: Performance Overview in Hot Humid Climate
Laboratory Evaluation of Hybrid and Advanced Water Heaters: Performance Overview in Hot Humid Climate American Council for an Energy Efficient Economy ACEE Hot Water Forum Nov. 4-5, 2013 Carlos J. Colon
More information2 Safety valve. 3 Pressure gauge. 4 Thermometer. 8 Ball valves
Standard solar system for domestic hot water heating (please adapt chart according to standard systems in your country) Standard engineering in Germany for a household of 4 people: 4 6 m² of collector
More informationKimberly Rollins, Professor, Department of Economics, University of Nevada, Reno
Modeling Multiple Factors of Residential Water Demand to Assess Price and Non-Price Instruments under Climate Change: An Application to Las Vegas, Nevada Kimberly Rollins, Professor, Department of Economics,
More informationHeat Pumps and Public Swimming Pools, a Perfect Match
TOPICAL ARTICLE Heat Pumps and Public Swimming Pools, a Perfect Match M. Zuliani, P. Pattijn - Belgium Public swimming pools have a very high energy consumption, due to high demands of heating and climatisation
More information