DC1192 Input /Output module

Similar documents
DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

DF1101-Ex Infrared flame detector

FDCIO223 (ES 45) Transponder

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

DM1131 / DM1133 / DM1134 Manual call points

DF1151-Ex Infrared flame detector

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

FDCL221-M Multi line separator module

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

Input module, input/output modules

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

DT1101A / DT1102A / DO110xA Automatic fire detectors

DOW1171 / DCW1151 Radio fire detection system

Output module (230 V)

Multi line separator module

Input module, input/output module

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

Synova TM product catalog.

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

OOH740, OOHC740 Automatic fire detectors

FC724 Fire control panel

Fire control panels FC726 FC726-XA

ASA linear smoke detector

FC722 Fire control panel

OOH740-A9-Ex Multisensor fire detector

OH720, OP720, HI720, HI722

FC724 Fire control panel

OOH740-A9-Ex Multi-sensor fire detector

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

FC2020 Fire control panel

FDOOT241-9, FDOOT241-A, FDO241, FDT241

FDCL221-Ex Line adapter (Ex)

FC723 Fire control panel

FS20 Fire detection system

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

FC722 Fire control panel

FDBZ290 Air sampling smoke detection kit

Fire control panels FC360

FDOOT241-A9-Ex Multisensor fire detector

FDBZ290 Air sampling smoke detection kit

FC2040. Fire control panel. Sinteso. FS20 series, MP6

Mimic display driver, LED ribbon cable

Interbases. Sinteso FDSB221, FDSB228, FDSB229

FDOOT221, FDO221, FDT221

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

XC10 Extinguishing control panels

Sinteso TM product catalog.

FT2080 Fire terminal (Touch) Mounting Installation

FT2080 Fire terminal (Touch) Mounting Installation

FDCL221 Line separator

FP120-Z1 Power supply kit A (70 W) Technical Manual

FC700A Fire detection control unit

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Building Technologies. FDUL221 en Line tester operating instructions for electricians

Fire & Security Products. Siemens Building Technologies Group

FDCW241 Radio gateway Mounting

FDCI221, FDCIO221 Input module, input/output module Technical Manual

FDA241, FDA221 Siemens ASD

Radio fire detection system

Fire control panel for modernization

For internal use only. Distribution (please mark): Product Solution Multi-channel x

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

FDL241-9 Linear smoke detector Mounting Commissioning

FDA241, FDA221 Siemens ASD

DICTATOR Hold-Open Systems for Hazardous Areas

FDCIO223 Input/output module (transponder)

General Routing Interface

Duct Temperature Sensors

FDCIO223 Input / output module (transponder)

Room Temperature Controllers

XC10 Extinguishing control unit XC1001-A / XC1005-A / XC1003-A. Installation Commissioning Maintenance. Building Technologies. A6V _e_en_--

BX-MDI8 Input module for SecuriLine extended

FDM273 Radio manual call point Mounting

FC121-ZA / FC122-ZA / FC123-ZA / FC124-ZA

System 800 Addressable Fire Detection & Alarm System

MK8000 OPC Server Interface Specification for CS1115 Building Technologies

Room thermostat with 24-hour time switch and large LCD

FDM221, FDM223, FDM224, FDM223H, FDM224H Manual call points

SWING radio fire detection system

FD20 Sinteso Detector system

Frost Units for air temperature monitoring

Electronic timeswitch

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Flush-mounted room thermostat

Room Temperature Controller

Sonos-SB Siren/Beacon

Application Sheet Chilled/heated ceiling (4 pipe) with 6-way valve on analog output

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

Control Products & Systems OEM

Fire alarm signal in areas at risk of explosion

OH720, OP720, HI720, HI722 Automatic fire detectors Technical Manual

CZ-6A Six Zone Interface Module

FDOOT241-A9-Ex Automatic fire detector Technical Manual

Transcription:

DC1192 Input /Output module Interactive, AnalogPLUS/SynoLOOP, collective/synoline600 AlgoRex Synova In-/output module suitable for collective fire detection system as detection line coupler interactive and AnalogPLUS/SynoLOOP fire detection system for the connection of up to 25 fire detectors with collective/synoline600 address, or for the connection of monitored alarm devices Operation with additional DC 24 V supply Microprocessor-controlled evaluation and line isolation function Housing for surface mounting with M20 cable entries Robust construction for use in dry, dusty and wet areas Control Products and Systems

Characteristics Function in the interactive and AnalogPLUS/SynoLOOP fire detection system Address assignment during commissioning via the key on the electronics unit. Correct addressing is indicated by the flashing of the LED. The key and LED are only accessible or visible when the housing is open. Application in the collective/synoline600 fire detection system For galvanic isolation (detection line coupler) between control unit and e.g. shunt Zener diode barrier SB3 with fire detectors for explosion-hazard areas. Application in the interactive and AnalogPLUS/SynoLOOP fire detection system For the connection of fire detectors with collective/synoline600 address (special detectors or via shunt Zener diode barriers, detectors for explosion-hazard areas) or for the activation of alarm devices. For connection on the line direct as a bus user. 24 VDC line collective/ SynoLINE600 or line collective-ex/ SynoLINE600-Ex or SB3 control line max. 2 A, 60 W detector line / loop max. 25 detectors Built-in line separators Any short-circuit on the detector bus is located from the central control unit and the defective part is isolated between two line separators. A ring-connection installation guarantees optimum safety. Installation The housing with cover DCA1191 and the terminal plate DCB1192A are required for installation. The housing has six M20 threaded cable entries to feed in the cable. The DCA1192A electronics unit is only inserted after the wiring check shortly before commissioning. 2

Components Housing with cover DCA1191 Circuit unit DCA1192A Terminal base DCB1192A Dimensions 65 135 135 6xM20 3

Technical data Primary line Collective line/synoline600 compatible with Connection factor KMK Interactive line compatible with Connection factor IMK Line separator factor ITK AnalogPLUS/SynoLOOP compatible with Connection factor APMK E3M080, CI1110/15, FC330A, FC10, FC700A, CZ10, KB24, GF24 1 E3M071, K3M071 2 1 E3M111, K3M111, CI1115, FC330A, FC700A 3 Secondary line Collective line/synoline600 Operating voltage Operating current Line resistance, depends on the type of line End-of-line unit Line factor KLK External supply Operating voltage Quiescent current (standby) Operating current, collective line Operating current, control line Ripple DC 18 22 V max. 5 ma 50 250 W EOL22 (Ex) 25 DC 18 32 V 45 ma 0.15 A 0.2 2 A max. 2 Vpp Control line Operating voltage Operating current End-of-line unit, resistor Wire cross-sectional area per terminal DC 18 32 V max. 2 A, 60 W 3k01, 1 %, ¼ W 0.2 2.5 mm 2 (AWG24 14) Operating temperature -25 +70 C Storage temperature -30 +75 C Humidity 95 % rel. Color housing white, ~RAL 9010 Protection category EN 60529 / IEC 60529 with DCA1191 IP56 Standards EN 54-17, EN 54-18 Approvals VdS LPCB G298021 126m/02 Further details can be found in the documents 'Fire protection in explosion-hazard areas', no. 1204 Connection factors for fire alarm detection system Nr. 001508 4

Details for ordering Type Part no Designation Weight DCA1191 BPZ:4588560001 Housing with cover 0,346 kg DCA1192A BPZ:5081200001 Circuit unit 0,135 kg DCB1192A BPZ:5084500001 Terminal base 0,070 kg DBZ1190-AA BPZ:4677080001 Auxiliary terminal, 0.28 0.5 mm 2 0,007 kg A5Q00004478 Metal screwed cable gland M20 x 1.5 0,039 kg Spare parts EOL22(Ex) BPZ:5162220001 End-of-line unit 0,006 kg 5

Issued by Siemens Switzerland Ltd Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41 724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2015 Technical specifications and availability subject to change without notice. Document no. 001571_j_en_-- Manual S11 / FD-C Edition 2016-04-20 Section 4 / 5