Thermolizer TZ6 & TZ17. Operators Manual

Similar documents
Feed Table FT42. Operator s Manual

EZ Melt Fill & Filter EZ18, EZ24 & EZ34. Operator s Manual

618L/624/634. Open Kettle Fryer. Operator s Manual and. Technical Supplement

616B & 616BT. Open Kettle Fryer. Operator s Manual and. Technical Supplement

Snack Master. Multi-Purpose Fryer. Operator s Manual

Donut Robot. Mark VID. Operator s Manual

Donut Robot. Mark V. Operator s Manual

718LFG, 724FG, & 734FG

The #1 Source for Donut and Bakery Equipment. Donut Fryer. Model: 616B

Donut Robot. Mark VI. Operator s Manual

Mark II & Mark II GP

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

SE Series Modular Electric Stone-Hearth Deck Oven INSTALLATION & OPERATION MANUAL LBC BAKERY EQUIPMENT, INC st Ave NE Tulalip, WA 98271, USA

HUMIDIFIERS OWNERS MANUAL A GUIDE TO OPERATING AND MAINTAINING YOUR HUMIDIFIER 49FH, 49FP, 49BF, 49WS, & 49BG

INSTRUCTION BOOKLET. Electric Steam Sterilizer

MODEL HUM HUMIDIFIERS

Fried Food Warmers Series. Series: FW Operation Manual

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

HOSHIZAKI ICE DISPENSING BIN/ WATER DISPENSER MODEL DM-90A SERVICE MANUAL

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

Wax Base Heater & Dispenser

Installation and Operation Manual

KD-CLN-LP200 Ultrasonic Vinyl Record Cleaner User s Manual English v1.2 Printed in Korea

Instruction Manual. Table Top Steamer Cart

HEDMAN DI-50. Endorser Instructions. Hedman DI-50 Operators Guide

SBF Series ELECTRIC CONNECTIONLESS STEAMER INSTALLATION - OPERATION - MAINTENANCE

User Guide. Please read this instruction manual before using your water dispenser. BOTTLED WATER DISPENSER MODEL BAE1SHSK C

WA A Aqua Sub Bottom-load Water Cooler

ULTRASONIC HUMIDIFIER With Night Light and Fragrance Diffuser

Instruction Manual. Astro Staging Cabinet

Electric Digital Kettle

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

VWD5976BL CAUTION: MISE EN GARDE: PRECAUCIÓN:

Installation, Operation, and Maintenance Manual RTE14S & RTE14S-2. For the Taco Bell "Rethermalizer" Model Numbers

Professional Warming Drawer and Warming Drawer Cabinet

Ultrasonic Humidifier

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

RCM-77. Instruction Manual. G-Series Cooler. Manual is for the following model: RCM-77-N23EB. U.S. Patent No. 8,215,125 RECHARGEABLE COLD MERCHANDISER

MODEL NO RUSSELL HOBBS APOLLO 1.8L DIGITAL FILTER COFFEE MAKER

CLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0036A

America s Walk-In Tub. Installation & Instructions. Manufactured by. A Division of Spa World Corp NW 35th Avenue ANSI-Z124.1

EVAPORATIVE COOL MIST HUMIDIFIER Instruction Manual

1.5 L Electric Kettle

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

Ventless Donut Center. Insider SUPPORT SUPPLÉMENT TECHNIQUE. The #1 Source for Donut and Bakery Equipment

SeasonMaker Hi-Line Fan-coil Units Model HSS S10 & S12

ANYWHERE. U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE

DZ5080 US Index01 19/09/07 10:50 Page 2

Bar Fridge USER MANUAL MB46W

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

Up to 60 Pint Commercial Grade DEHUMIDIFIER

ULTRASONIC HUMIDIFIER

PLEASE READ BEFORE USE AND SAVE. Ultrasonic. with Ionization. INSTRUCTION MANUAL MODEL HUNi

Warming Drawer Use & Care Guide

ELECTRIC FLAT PANEL FIREPLACE HEATER

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

AHPO-6/18 GOLD PROOFER OVEN

Use and Care Instructions

Questions or concerns about your electric kettle? Before returning to the store...

Upright Freezer 048-GM-48307

SERVICE & TROUBLESHOOTING MANUAL FOR DISPLAY HOLD CABINETS DHC SERIES

Instruction Manual. Portion Cup Cheese Warmer

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

IMPORTANT SAFEGUARDS SAVE THESE INSTRUCTIONS

COOL MIST HUMIDIFIER USER MANUAL FOR MODEL: PAU1. Your Source for Home Comfort

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

SAVE THESE INSTRUCTIONS

Mobile Hot Food Merchandiser Series. Series: MHB Operation Manual

WCD-210BK. Water Dispenser OWNERS MANUAL. Read and save these instructions.

CLEAN MIST DUAL TANK SMART HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0036A

ONE PIECE TOILET LT3. Model: MPN: B0940 INSTALLATION INSTRUCTIONS. Version: 1.0

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU

Instructions for set-up, use and cleaning

Compact Refrigerator. User Manual Model 3590A

Ultrasonic Humidifier

DIGITAL ULTRASONIC HUMIDIFIER WITH HUMIDISTAT

Instruction Manual. Cheese Warmer with Pump

USER S MANUAL. MODEL NO. CLTL100 (White) CLTL120 (Black) Top-Load Water Cooler

TOASTER OVEN INSTRUCTION MANUAL

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

SeasonMaker Hi-Line Fan-coil Unit Model HSS S30 through S80

CLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0040A

WALLPAPER STEAMER. Model ASSEMBLY AND OPERATING INSTRUCTIONS

ULTRASONIC humidifier

Reliability is a beautiful thing TM MODULAR FLAKER F-800MAH(-C) F-800MWH(-C) INSTRUCTION MANUAL

Important Safeguards. Topic 2 SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY 3

USER'S MANUAL PGE Single Package Rooftop

Operation and Maintenance Manual BLIZZARD50 CS6-50-VD 120V/60HZ

WCD-200W Water Dispenser

AUTO SPEED BLENDER INSTRUCTION MANUAL MODEL: BLCLMB1

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

18 INCHES, OSCILLATING STAND FAN

CLEAN MIST SMART HUMIDIFIER TABLETOP & FLOOR STANDING WITH REMOTE CONTROL. Instruction Manual and Warranty Information

Air Paper Jogger AJ-700 Operation Manual. Keep this manual at hand where it can be referenced at any time.

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL

ULTRASONIC HUMIDIFIER MODEL# BU6000 INSTRUCTION MANUAL

Transcription:

Thermolizer TZ6 & TZ17 Operators Manual Belshaw Bros., Inc. 814 44 th Street NW, Suite 103 Auburn, WA 98001 USA Phone: 206-322-5474 Fax: 206-322-5425 Email: service@belshaw.com http://www.belshaw.com

Congratulations on buying a new Thermolizer from Belshaw Bros., Inc. Please inspect the unit carefully for damage or missing pieces immediately after receiving your system. Belshaw cannot pay for shipping damage, because the freight company has accepted the machine from Belshaw in good condition, and is responsible for its safe delivery. For your protection, each crate should be inspected before signing the Bill of Lading to report any visible damage caused by the trucker in transit, and account for the number of crates. IMPORTANT Keep this manual for future reference. EQUIPMENT RECORD Please provide the information below when you correspond with us about your machine. Purchased by Installed by Date of Installation Model number Serial number 120308 MN-1257EN Belshaw Bros., Inc. 814 44 th Street NW, Suite 103 Auburn, WA 98001 USA Phone: 206-322-5474 Fax: 206-322-5425 Email: service@belshaw.com http://www.belshaw.com

Contents 1 Operation 1 Control Functions 1 Operation Instructions 1 2 Cleaning 3 Water Box 3 Thermolizer 3 Water Filtration System 3 Thermolizer TZ6 & TZ17 OM MN-1257EN iii

Preface The Thermolizer is designed for retail bakeries, in-store bakeries and donut shops. It features two individual insulating clear acrylic doors with stainless steel tops, bottoms and ends, to enable loading and unloading of 3 screens or bun pans per door. This minimizes heat and humidity loss. The air is recycled every 18 seconds. A thorough understanding of how to operate, clean, and maintain the Thermolizer safely will prevent production delays and injuries. The operator must work safely at all times, read and follow the instructions in this manual, and heed all warnings, including the following: To avoid electrocution or other injury, turn off the machine s main power before attempting any cleaning, disassembly, adjustment, or repair. To avoid damaging the machine, never use force to assemble, disassemble, operate, clean, or maintain it. Be careful never to get water or other materials on the floor. If anything does get spilled on the floor, mop it up immediately. Materials on the floor can cause people to slip or fall, resulting in serious injury or loss of life. To prevent unintentional startup and possible fire, disconnect the machine from the power source if there is a local power outage. When the power is restored, it is safe to connect the machine to the power source again. To avoid electrocution, make sure that all electrical cords are not frayed or cracked and that they do not pass through any water. Make sure that all electrical cords are routed so that no one will trip over them. If water is spilled while cleaning the proofer, be sure to dry the floor thoroughly. The autofill unit must be turned on to insure water is contained in the water box. Check often. Use only soft or distilled water in the operation of this thermolizer. iv MN-1257EN Thermolizer TZ6 & TZ17 OM

1 Operation Control Functions A. HUMIDITY CONTROL: This control is located inside the control box front panel and can only be adjusted by a qualified technician. It controls the water heating element. Set on high, the water heat element will remain on constantly. Set on any setting other than high, the control will cycle on and off. Higher numbered settings create a longer on-cycle and high humidity. The factory setting is 4.5 on the dial. B. HEAT CONTROL: This control is located inside the control box front panel and can only be adjusted by a qualified technician. It controls the air-heating element. The factory setting is: place the dot on the knob at 11:00 to produce 95-110F. C. CONTROL BOX POWER SWITCH: Controls the power to the control box. CAUTION Do not permit water pan to run out of water. Check often. Use only soft or distilled water in the operation of this proofer. Operation Instructions CAUTION If water is spilled while filling the water pan, thoroughly dry all surfaces including the floor. Spilled water may cause serious injury, loss of life, or damage to equipment. Water may continue to drip. To prevent the floor from becoming wet and slippery, use a pan to collect dripping water. Do not move the proofer when water is in the reservoir. Note: Use only distilled or purified water in the Thermolizer to avoid build-up in the water box of minerals and deposits normally found in tap water. 1. Lift off water reservoir cover and fill water reservoir (see Figure 3). If necessary, open the lower door(s) and remove screen(s) or tray(s) to access the water reservoir. Do not fill beyond ½ of the top edge. When finished, replace the cover and doors. If equipped with the autofill unit, turn on the water and the filler unit will stop at the correct water level. Note: Do not pull the control box out to gain access to the water reservoir because water may be spilled when moving the control box. 2. Turn on control box power switch. 3. Wait 25 minutes for the Thermolizer to reach operating temperature. Thermolizer TZ6 & TZ17 OM MN-1257EN 1

FIGURE 3 2 MN-1257EN Thermolizer TZ6 & TZ17 OM

2 Cleaning Water Box Once per day, clean the water box and reservoir as follows: 1. Remove the water reservoir cover. 2. Mix an appropriate cleaner into the water box and reservoir. 3. To break down lime scale, add 100-grain vinegar. 4. Brush the heating elements and float assembly to remove lime scale and sediment. 5. Remove water and cleaning solution. 6. Rinse thoroughly. Thermolizer Once a week, clean the Thermolizer as follows: 1. Remove and clean Plexiglas doors with warm water. 2. Disconnect from power and remove control box from cabinet. 3. Remove and clean the screen rack angles, angle supports, and air duct. 4. Wipe the cabinet interior clean. 5. Special attention should be given to cleaning the water box (Item 2 of Control Box Assy., parts list drawings). Clean the water box as follows: a. Turn off water to the Thermolizer control box. b. Remove water reservoir cover. c. Empty the water reservoir pan. d. Remove water box access cover thumb screw and rotate access cover to open position. (see Figure 3) e. Use a rubber syringe baster to remove sediment from the water box. Wipe the inside of the water box with a rag. f. Add a small amount of water to the water reservoir pan. Water should flow freely into the water box. If not, clean out the water line between the water box and the water reservoir pan. Check for blockage at the water box inlet hole first. g. Close water box access cover and fasten with thumbscrew. h. Replace water reservoir cover. Water Filtration System Clean any water filtration system per the manufacturer's instructions. Following are some cleaning charts to help keep track of regularly scheduled cleaning. Thermolizer TZ6 & TZ17 OM MN-1257EN 3

Cleaning Dates (Write In) Drip Pans Cleaned (Check or Initial) Proofer Box Cleaned (Check or Initial) 4 MN-1257EN Thermolizer TZ6 & TZ17 OM

Cleaning Dates (Write In) Drip Pans Cleaned (Check or Initial) Proofer Box Cleaned (Check or Initial) Thermolizer TZ6 & TZ17 OM MN-1257EN 5

Thermolizer TZ6 & TZ17 Technical Supplement Belshaw Bros., Inc. 814 44 th Street NW, Suite 103 Auburn, WA 98001 USA Phone: 206-322-5474 Fax: 206-322-5425 E-mail: service@belshaw.com http://www.belshaw.com

Congratulations on buying a new Thermolizer from Belshaw Bros., Inc. Please inspect the unit carefully for damage or missing pieces immediately after receiving your system. Belshaw cannot pay for shipping damage, because the freight company has accepted the machine from Belshaw in good condition, and is responsible for its safe delivery. For your protection, each crate should be inspected before signing the Bill of Lading to report any visible damage caused by the trucker in transit, and account for the number of crates. IMPORTANT Keep this manual for future reference. EQUIPMENT RECORD Please provide the information below when you correspond with us about your machine. Purchased by Installed by Date of Installation Model number Serial number 120308 MN-1258EN Belshaw Bros., Inc. 814 44 th Street NW, Suite 103 Auburn, WA 98001 USA Phone: 206-322-5474 Fax: 206-322-5425 Email: service@belshaw.com http://www.belshaw.com

Contents 1 Installation 1 Unpacking and Assembling the Thermolizer 1 2 Maintenance 3 3 Troubleshooting 4 4 Appendix 7 Thermolizer TZ6 & TZ17 TS MN-1258EN iii

Preface The Thermolizer is designed for retail bakeries, in-store bakeries and donut shops. It features two individual insulating clear acrylic doors with stainless steel tops, bottoms and ends, to enable loading and unloading of 3 screens or bun pans per door. This minimizes heat and humidity loss. The air is recycled every 18 seconds. A thorough understanding of how to operate, clean, and maintain the Thermolizer safely will prevent production delays and injuries. The operator must work safely at all times, read and follow the instructions in this manual, and heed all warnings, including the following: To avoid electrocution or other injury, turn off the machine s main power before attempting any cleaning, disassembly, adjustment, or repair. To avoid damaging the machine, never use force to assemble, disassemble, operate, clean, or maintain it. Be careful never to get water or other materials on the floor. If anything does get spilled on the floor, mop it up immediately. Materials on the floor can cause people to slip or fall, resulting in serious injury or loss of life. To prevent unintentional startup and possible fire, disconnect the machine from the power source if there is a local power outage. When the power is restored, it is safe to connect the machine to the power source again. To avoid electrocution, make sure that all electrical cords are not frayed or cracked and that they do not pass through any water. Make sure that all electrical cords are routed so that no one will trip over them. If water is spilled while cleaning the proofer, be sure to dry the floor thoroughly. The autofill unit must be turned on to insure water is contained in the water box. Check often. Use only soft or distilled water in the operation of this thermolizer. iv MN-1258EN Thermolizer TZ6 & TZ17 TS

1 Installation Unpacking and Assembling the Thermolizer Use a forklift to transport the shipping crate to the workstation. 1. Break down the shipping crate. 2. Remove the packing materials from the thermolizer, including foam, tape, brown paper, plastic, and white protective coating. Do not remove the plastic from the Plexiglas doors at this time. 3. Cut the bands holding the control box in place and remove the control box from the cabinet. 4. Remove and discard the plywood that the control box was resting on. 5. Inspect the machine to see that no parts are bent, scratched, or otherwise damaged. If any damage has occurred in shipping, file a freight claim with the shipping company immediately. 6. Clean the humidifier water box and attach to filtered water per plumbing codes in your area. Refer to Section 3 for cleaning instructions. 7. Install screen rack angles onto angle supports by tilting the angles up and sliding the flange into the notches of the supports. See Figure 1. WARNING If water is spilled while cleaning the thermolizer, be sure to dry the floor thoroughly. Figure 1 8. If not already done, remove the packing material from the control box and the put water reservoir cover in place over the water reservoir. 9. Place the control box into the cabinet, push the cord through the hole in the bottom to the right of the control panel, and close the cord opening cover plate. 10. Remove the protective covering from the Plexiglas doors. Clean the doors with warm water. 11. Insert the hinge pin on the right side of the door into place, and then slip the left side hinge pin into the slot. Thermolizer TZ6 & TZ17 TS MN-1258EN 1

Note: due to vibration in shipping, the door handles might get out of adjustment. To adjust door handles: loosen the screws which fasten the handle to the Plexiglas door, adjust position of the handle so it just clears the bottom of the door above when both are closed, and tighten the screws. If more than one door handle requires adjustment, start with the one nearest the top of the proofer and work down. 12. Turn the control box power switch to the off position (see Operation Instructions) 13. Connect Thermolizer cord to power source provided from the ThermoGlaze main power box. Mail the attached warranty registration form within ten days of installation. 14. Keep this manual for future reference. Put it where you know you can find it. Control Box with Auto Water System Remove the control box top to install the auto water line. After installation, replace the top and seal it with silicon seal 909-0021.F. Initial Cleaning Remove all the packing materials. Wipe the Thermolizer with a soft, damp cloth. Dry these areas completely. WARNING To avoid electrocution or other injury, turn off the machine s main power before attempting any cleaning, disassembly, adjustment, or repair. 2 MN-1258EN Thermolizer TZ6 & TZ17 TS

2 Maintenance The Thermolizer requires no maintenance, other than the daily/weekly cleaning. Thermolizer TZ6 & TZ17 TS MN-1258EN 3

3 Troubleshooting If you have problems with your Thermolizer, call your dealer or another qualified technician. If your dealer cannot help you, please call Belshaw. To do so, first dial the appropriate international access code, then 1-206-322-5474 (United States). When you call, please specify the following: The model name of the machine. The serial number of the machine. The voltages, phase, and cycle of the machine. WARNING If you perform repairs yourself or have them performed by anyone other than a service technician authorized by Belshaw Bros., you do so at your own risk. WARNING Disconnect the machine from the power source before disassembling, repairing, or wiring. 4 MN-1258EN Thermolizer TZ6 & TZ17 TS

THE PROOF BOX WILL NOT HEAT UP Possible Causes Control box power switch is not on. Defective heat control. Loose wire or bad connection. Defective heat element. Defective control box power switch. What To Do Flip switch to on position. Replace the heat control. Repair the wire. Replace the heat element. Replace power switch. LACK OF HUMIDITY OR UNEVEN HUMIDITY Possible Causes Low water. Defective humidity control. Defective water heat element. Restriction or sediment in the water line or the water heat box inlet hole. Loose wire or bad connection in humidity circuit. Blower is not running. Doors out of alignment. What To Do Refill water reservoir/check water is on. Replace the humidity control. Replace the water heat element. Clean out water line. Repair loose wire or connection in humidity circuit. See Blower Will Not Run section Align doors. Thermolizer TZ6 & TZ17 TS MN-1258EN 5

BLOWER WILL NOT RUN Possible Causes Control box power switch is not on. Defective blower motor. Defective control box power switch. Loose wire or bad connection in blower control circuit. What To Do Flip switch to on position. Replace blower motor. Replace control box power switch. Repair loose wire or bad connection. 6 MN-1258EN Thermolizer TZ6 & TZ17 TS

4 Appendix See Parts List Drawing Insert Page. Thermolizer TZ6 & TZ17 TS MN-1258EN 7