BP Alaska GC-1. Design Review Project. January 2003

Similar documents
Dependable Solutions for Gas Detection

Architectural and Engineering Specification for a Real-Time Locating System Flare

SafEye Quasar 900 Open Path Gas Detector Quick Start Guide Installation and Calibration Procedure

Technical Handbook. Sieger DX100 Series Termination Units

Zareba System Overview

Technical Summary. Searchpoint Optima Plus Specification. Output ma sink or source, (Default current source) 0-4 ma (Default 4 ma)

Searchpoint Optima Plus

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Sieger fixed gas detection. Fixed protection from hazardous gas

-Industrial. W hen All Else Fails... Difficult Applications. The Only TRULY Industrial Air Sampling Detector For Hostile and Difficult Environments

Substation Monitoring System

PUV, PIR and PFO Series BROCHURE

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

Improved Dryer Control

Failure Modes, Effects and Diagnostic Analysis

L CONNECTION NETWORK Commercial Controls

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

SEC Signature Process Gas Analyzer

Spectron LSN (Life Safety Network) Suggested Specifications

Altman Lighting Spectra Cyc UV 50 Specification

Dräger Polytron Pulsar 2 Open Path Gas Detector

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

FIRERAY 5000 range USER GUIDE

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

Tune-Rite Software Operation Manual

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Recalibrate the way you look at gas detection

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Senscient s team has more than 150 years collective experience in gas. detection.

Line Smoke Detector LRMX

Intelligent Earliest Warning Aspirating Fire Detector

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

Dräger Polytron 8700 IR Detection of flammable gases and vapors

ADPRO PRO Passive Infrared Detector. Webinar November Ben Klösen, PLM

Advanced Radiation Measurement Solutions

SECTION Fluorescent Dissolved Oxygen Measuring System

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

User s Manual. YTA110, YTA310, YTA320, and YTA710 Temperature Transmitters. Manual Change No

SUPREMATouch. Modular Fire & Gas Detection System

Technologies, Solutions, and Applications. Radiation-based Level

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

SUPREMATouch. Modular Fire & Gas Detection System

PHOENIX L300i New Standards in Helium Leak Testing The next Generation

EST User Manual. (Please read this manual carefully before using)

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

Open the Door to Increased Productivity and Cost Efficiency

Industrial Grade Gas Detection

Security Management System - Configuring Video Analytics

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions!

We know what it takes...

CombustionONE. Improving and Sustaining the Combustion Asset. Driven by the New Standards. Bulletin 53A90A01-01E-A

F3SJ Overview. Three Versions available to meet your exact safety needs. Safety Light Curtains NEW! Introducing the F3SJ Series

CS744 Series: Carbon/Sulfur by Combustion

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

Reflective Optical Beam Smoke Detector User Guide

Searchpoint Optima Plus

The Growing Viability of UV LED for Wide Web Coating Applications. Tuesday, October 11, 2016

Safety Manual. XNX TM Universal Transmitter. Table of Contents SIL 2 Certificates Overview Safety Parameters

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

Electro-Sensors is revolutionizing the way hazard monitoring is done, with its turnkey HazardPRO TM systems. Rugged sensors and the most advanced

Product Specifications

Dräger Polytron 8310 Stationary gas detector (DSIR)


High Integrity Pressure Protection System

IE Code IE Competency Title Credit OAC Ref.

Installation and Operation Manual

CONTROL SYSTEMS Combustion Control Burner Management Control Balance of Plant Equipment Control Supervisory Control and Data Acquisition

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Sieger Apex. Flexibility that meets your requirements

REFRESH, UPGRADE, PERFORM. Revamping Kits and Digital Solutions for quality improvement and energy savings

MULTI-POINT DENSITY ARRAY FIXED-POINT INTERFACE PROFILING MEASUREMENT

PHOENIXL 300 New Standards in Leak Testing. Technical information

Waters 2695D Separations Module

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

ThermoMax Steam System Efficient. Reliable. Consistent.

Advance Optima Module Magnos 17

Dräger Polytron 5720 IR Detection of carbon dioxide

The Basics of Package/Device Cooling

Installation Instructions Wall Ovens

Fixed-Point Interface Profiling. Multi-Point Density Array (MDA) Solution for Separation Applications

Beam Detectors. The 6500 Series

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

ACTIVE INFRARED BARRIER

Transcription:

BP Alaska GC-1 Design Review Project January 2003

January 03 _03 January BP Alaska GC-1 Design Review Project I. Statement of requirement The objective of this report is to review the current design drawings for the Gas Detector Installations for BP Alaska s Prudhoe Bay GC-1 Project. The current design incorporates the Spectrex OPGD detectors. Scope of this report includes: 1. Our recommendations regarding the current gas detector placements. 2. Any changes to the current design (placement, wiring, mounting, etc) that would need to be implemented in order to use the Zellweger OPGD EXCEL gas detector systems instead of the currently specified vendor. 3. The advantages Zellweger products offer during the construction and installation process resulting in a LOWER COST to BP Alaska on their initial project overall cost estimate. 4. The advantages that Zellweger detectors offer during the start-up, commissioning and troubleshooting for this particular site resulting in a LOWER COST to BP Alaska on their initial project overall cost estimate. 5. Long Term Cost of Ownership Advantages

II. Technical Assessment of Current Design Detector Placement, Power Requirements, and Wiring After careful review of the drawings, we conclude that the specific placement locations for the detectors are logical and consistent with the effective use of open path gas detection technology. The placements, as we see them, should effectively maximize detection coverage in the module and minimize the risk of significant, undetected combustible gas leaks in the module. The placement of the standard configuration OPGD detectors across the ceilings and at the various levels of height in these modules is consistent with our opinion on the most likely locations where slow leaks might build up into significant combustible gas concentrations. The placement and utilization of the Cross-Duct configuration OPGD detectors look to both maximize the efficacy of the technology and reduce the risk of missing an unexpected release of combustible gases from outside the module that might be drawn inside the module through the HVAC ducting. We have based our statements here on our knowledge of our own open path gas detection systems operation and capabilities, as well as shared input from many of our customers past experiences with this technology. We conclude that no significant changes to the current placement design would be recommended for this project. We specifically note, in reference to the placement and wiring of these systems, that we do not see any significant changes that would need to be made in these design drawings in order to replace the currently specified Standard open path gas detection kits with the Zellwegerbrand Searchline EXCEL OPGD systems. One important change, related to the Cross-Duct configurations, would be required. But the changes are certain to be an advantage. These advantages will be discussed in detail in Sections III and IV of this report. There are a number of available features and configuration options, specific to the Zellweger products, which we can recommend. These recommended options and features will improve the ease of mounting for these detection systems, increase the ease and speed of alignment and facilitate the problem-free start-up of the gas detection systems during initial construction and installation. These options and features can also effectively reduce the difficulties that can be encountered during commissioning of the system and initial troubleshooting, should there be any question regarding the viability of their operation. These changes are certain to provide specific time and material cost reductions that will reduce the estimated project costs associated with the GC-1 Gas Detection upgrade effort. The standard features of and specific configuration options for the Zellweger Searchline EXCEL product line will also benefit BP Alaska in their long-term Cost of Ownership.

III. Advantages of the Zellweger products during the construction and installation phase. Powering Requirements: The power supplies used in Excel & Optima are constant power draw, switched-mode type power supplies. No change in power will be drawn with varying supply voltage and no surge at switch-on. The power supplies employed in Searchline Excel ensure that the maximum unit powerconsumptions are never exceeded, even at power-up. This allows the cabling and power supply calculations to be met with confidence. This should result in no unexpected modifications to the power requirements during the start-up process. Each Zellweger Searchline Excel unit consumes less than half of the maximum power consumed by some of the other vendors products. (For Example, Zellweger Analytics Excel OPGD (Max) = 13W per complete system (both source and receiver, Draeger s Pulsar (Max) = 35W). Reduces demands upon power supply and cabling. Wiring Requirements: For the Standard OPGD gas detections systems, no change in wiring or communications cabling would be required. However, the duct mounted Zellweger OPGD systems would only need power and RS- 485 cabling / connections brought to a single position on only one side of the duct. This will save one set of power cabling and one mounting hardware construction event on each duct-mount installation. The specific costs of this reduction could be reduced as much as 50% for the installation of the Cross Duct OPGD s for the project. Searchline Excel Cross Duct OPGD System

III. Continued Mounting Bracket Flexibility: The mounting bracket designed for the Searchline Excel Standard OPGD system allows > 180 degrees horizontal and +/- 45 degrees vertical movement of Excel unit when mounted. This accommodates all likely pointing arrangements without requiring special supports to be produced that "pre-align" the detector in roughly the right direction. The currently specified vendor s units have mounting brackets limited in their movement. The mounting bracket from the currently specified vendor is limited to - 45 deg in the horizontal plane making it impossible to wall mount and fire along the wall.they appear to be well suited to installing units on opposite walls but will be limiting for units running along the same wall, should BP Alaska s locations require such installations. Other vendor s OPGD system mounting brackets may only allow +/- 30 degrees movement in either plane, requiring special supports to be built, when the units are to be mounted on opposite walls. Standard Searchline Excel OPGD System bracket - exploded view

III. Continued Standard OPGD Alignment Procedure: Instrumentassisted Alignment is used with all Zellweger standard configuration EXCEL kits. The telescope procedures associated with the currently specified OPGD systems is similar to the course alignment telescoping procedures for the Zellweger EXCEL OPGD systems, but the use of the Hand Held Interrogator in the Zellweger system allows for fine tuning of that alignment. The hand-held unit facilitates optimum alignment accuracy and digitally confirms the correct and acceptable signal level from the source to the receiver. The software for the hand-held will NOT allow initialization of the system, unless the minimally acceptable signal levels are achieved, indicating acceptable alignment accuracy. Searchline Excel, Excel Duct Mount and Optima Plus can all be communicated with using a single, common SHC-1 Handheld Interrogator. The currently specified OPGD units have no hand-held unit access. A notebook pc and software is required to perform simple programming and troubleshooting. Other vendor s systems may have a different handheld for each detector type. Although other manufacturers units may require a connection between the transmitter and the receiver, Standard Searchline Excel units can be wired using the same cabling arrangements as the currently specified, Spectrex SafEye units. Cross-Duct Installation: Currently specified and other manufacturers cross-duct OPGD units have a separate source and receiver module that must be mounted on mounting plates located on each side of each duct. This could be very difficult to accomplish for the construction crew, depending upon the clearance between the ducts walls and the ceiling or module wall due to the optimal positioning of the line of sight.

III. Continued Cross-Duct Alignment Procedure: Cross-Duct alignment for the currently specified detection system can be cumbersome and time-consuming. The unit must be aligned during the actual construction event, potentially requiring a separate, trained instrument technician to be available during this process. The Zellweger EXCEL Cross- Duct OPGD does not require alignment of any kind in the field. The unit comes pre-aligned at the factory and simply needs to be bolted to it s mounting bracket/plate, wired in, and connected to the power supply for on-demand start-up. The hermetically sealed Reflector Panel mounts on the opposite inside wall of the duct and does not have to be accurately aligned. The signal does not have to be directed to the exact center of the plate due to the stable and accurate mounting of the optical components and the focusing of the beam within the specially designed mounting cell in the Cross-Duct kit.

IV. Advantage of Zellweger products during start-up, Commissioning and Troubleshooting: Functional Testing of Standard Configuration Open Path Detectors: Functional testing can be performed with test filters for any and all standard open path gas detection systems in the design. However, many units are mounted at levels much higher than can be reached from floor level. For systems mounted up to 15 feet above the floor, a telescoping wand accessory is currently available from Zellweger. The test filters are mounted in the clamp of the wand and lifted into the path of the OPGD system for response verification. Due to their location, open path combustible detectors that are mounted high up in the module up to 30 meters, such as DACG-010454-5, will be difficult to access for alignment confirmation, system initiation, calibration and performance validation, programming, diagnostics, etc. The need for gaining direct access to such detectors can be significantly reduced by doing the following: 1. Remote System Access: BP Alaska could choose to install the Searchline Excel receiver with its conventional junction box close to the unit and a cable / conduit coming down to a DX-100 M interface box mounted where it can be readily accessed from the floor. The DX100M interface is unique to Zellweger Analytics, with an IS connection for the Hand-held Interrogator. It was designed for non-intrusive one-man access to the OPGD units. All user-programmable parameters can be accessed through the hand-held device. The SHC-1 Hand-Held is a simple, 4-button, menu driven interrogation device that is easy to operate. This is not possible with the currently specified vendor s systems. 2. Remote Real-Gas Calibration Verification: For use inside the BP Alaska process modules, a Searchline Excel gassing cell accessory could be permanently installed on the receiver and tubing can be installed flowing into this cell from where the DX-100 (M) is located. Calibration gas would be remotely applied to the cell, and a real gas system operational test would be accomplished. The outlet of the cell would also be fitted with tubing and the effluent gas vented several feet away from the path of the detector.

IV. Continued Gas cell verification performed using the gas cell will be less prone to microscopic variations in thickness / changes in orientation of the filter and so will give a more accurate result than the placing of a test filter in the OPDG beam. The use of gas as a primary standard is used in the factory calibration of the Searchline Excel and repeating this on site with the Sieger gas cell will give the most accurate form of functional testing of the installed device. By installing the receiver unit as described above it will be possible to perform functional testing, configuration and diagnostic activities from the convenience of the floor. The only activities that will not be possible from the floor will be the cleaning of windows (if necessary) and the system alignment procedure. For the initial alignments during construction, the hand-held interrogator would be used connected to the standard junction box with the aid of an SHC-1 Protection Device and Lead.