Push Button Electronic Timer. 31VETR Series. Installation Instructions

Similar documents
Push Button Electronic Timer. 31VETR3 Series. Installation Instructions

Trailing Edge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

TrailingE dge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

Indoor Infrascan Passive Infrared Motion Sensor. Series. Installation Instructions. Please leave these instructions at the installation site.

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

QUICKSMART Universal Exit Light EXITSM. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Universal Dimmer E450UD Series. Installation Instructions

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

Mains Power Filter 970MF10 970MF20. Installation Instructions

WAFER Recessed Edgelite Exit LED EXITREC. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

INDOOR INFRASCAN. Passive Infrared Motion Sensors 751 SERIES INSTALLATION MANUAL. Please leave these instructions at the installation site

F Type Shielded Masthead Amplifier 3105MH35U18V DIGITAL TERRESTRIAL TELEVISION READY. Installation Instructions

Dimmer / Fan Controller Installation Instructions

C-Bus Black & White MK II Touch Screen. 5000CT2 Series. User s Guide

C-Bus Black & White MK II Desktop Touchscreen. 5000CTD2 Series. User s Guide REGISTERED DESIGN REGISTERED PATENT

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

Line Isolation & Overload Monitor. E05 Series. Installation Instructions MU TE TE S T E. S.P. ALARM MUT E D OVE R LOAD WAR NING PHC WARNING

Light Level Detector, Surface Mount 5754PE. Installation Instructions

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

Iconic Series ControlLink Pushbutton 41EPBM-VW PDL356PBSS-VW. Installation Instructions REGISTERED DESIGN

Passive Infrared Motion Detector 5420/90P. Installation Instructions

Three Speed Capacitive Fan Controller. 4060CSFM Series. Installation Instructions 75VA

Universal Clamp Meter

60W Security Spotlight. 754HB1/180/ Outdoor Motion Sensor. Installation Instructions. Please leave these instructions at the installation site.

Motion sensors for every application

Consumer Switchboards 4CS & 4FCS. Installation Instructions

Airflow. Add a little Sunshine to your bathroom

Get connected with Xantrex Grid-Tie Inverters

MLHG6-AU. Iso-Gard Line Isolation Monitor (LIM) Setup Guide ! WARNING. Components

754 Series. See Motion Sensors. in a new light. Sleek new styling and more features than ever before.

DON T WAIT UNTIL IT S TOO LATE! Discover the seven steps to a safe and secure home.

Ceiling Mounted Ducted Exhaust Fan Kit

Smoke Alarms. Clipsal FireTek. Photoelectric Smoke Alarms. clipsal.com/smokealarms

DALI Product Range. Designed in Australia to be compatible for all DALI systems. gerardlighting.com.au

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

C-Bus Four Channel Analogue Output Unit Installation Instructions

Airflow. The coolest way to save energy

Mini. Level Control systems For Manual Sump Pumps up to 750W 1 or 2 Pump Systems

Intercom Systems Video Intercoms

SMART HOME LIGHTING CONTROL C LIPSAL

C-Bus Four Channel General Input Unit Installation Instructions

C-Bus Reflection Range Installation Instructions

C-Bus Neo Range Installation Instructions. 5050NL Series

Energy cost saving made easy!

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Setting the Timer...

Wall Fan. 3 Speed, 40cm MWF40

Clipsal Mining Solutions. Increasing workplace safety. Adding value to mining operations.

1.7L KETTLE INSTRUCTION MANUAL 220~240V 2200W

60cm Built-In Ceramic Cooktop

Integrated PIR detectors

WARRANTY BOOKLET. Hotflo (HFE) Series. Electric Storage Water Heaters. Register online at

WARRANTY BOOKLET. EHPA Electric Heat Pump Water Heaters. Register online at

Model pictured: RPA3CI6SS/WH

C-Bus Application Note. Function Rooms and Ballrooms. Overview

compact office 24V compact office 24V Lux

6.5L SLOW COOKER INSTRUCTION MANUAL

Installation and Operations Manual

Operation, Maintenance and Installation Manual

TRAVELMATE. Instruction Manual

Lighting and Energy Control

TEMPAIR 3 IN 1 EXHAUST FAN SKU# &

compact office 24V compact office 24V Lux

Lighting & Energy Efficiency

OPERATING INSTRUCTIONS

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

Wireless Electricity Monitor. User Manual REGISTERED PATENT

HOME OWNER S MANUAL DUCTED GAS HEATER. (with MagIQtouch Controller or Manual Thermostat)

Drying Cabinet With Timer

PräsenzLight PräsenzLight PräsenzLight A.. PräsenzLight A..

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual

Lighting and Energy Efficiency

OPERATING INSTRUCTIONS

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

Flexibility from floor to ceiling

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Section B Unit Maintenance...

SENSA MRE DDM MR

Reflector T2 and GU10 6,000 hours

Pedestal Fan. 12 months. 3 Speed, 40cm R2000B

PRODUCT MANUAL. TT-MTM2 Hard-Wired Controller with Remote

Blender. brushed stainless steel housing BTBL55

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

WARRANTY BOOKLET. Commercial Hot Water. Register online at

Direct Dim Microwave Presence/Absence Detector

Instruction Manual. Please read this manual and the Safety Instructions carefully before using your refrigerator.

Installation Instructions

Table of Contents. Features Quality Policy Section A - Unit Operation Section B Unit Maintenance Trouble Shooting Guide...

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

LABORATORY ILLUMINATED FLOTATION BATH

PresenceLight 180 PresenceLight 360

Dome Kettle. polished stainless steel body BTDK120

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Evaporative Cooler. 8 Litre MEC1R

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Transcription:

Push Button Electronic Timer Series Installation Instructions

Contents 1.0 Product Range... 3 2.0 Description... 3 3.0 Features... 3 4.0 Important Warnings... 3 5.0 Timer Control... 4 5.1 Push Button Control... 4 5.2 Indicator Function... 4 5.3 Remote Operation... 4 6.0 Wiring Diagrams... 4 6.1 Local Operation... 4 6.2 Remote Operation... 4 7.0 Special s... 5 7.1 Product Selection... 5 7.2 Handling Special s... 5 8.0 Timer Settings... 6 8.1 Timer Adjustment Settings... 6 8.2 Example Settings... 6 9.0 Electrical Specifications... 7 10.0 Warranty Statement... 8 Copyright Notice The concepts, products and designs described in this document are the subject of international patents, and protected by international law. Copyright Clipsal Australia Pty Ltd. All rights reserved. Trademarks Clipsal is a registered trademark of Clipsal Australia Pty Ltd. All other logos and trademarks are the property of their respective owners. Disclaimer Clipsal Australia Pty Ltd reserves the right to change specifications or designs described in this manual without notice and without obligation. 2 of 8 Copyright Clipsal Australia Pty Ltd

1.0 Product Range 20 Electronic Timer, Push Button, 220-240V~, 50Hz, 10AX (Standard Range) Electronic Timer, Push Button, 220-240V~, 50Hz, 10AX (2000 Series) * Please note that these products are also available in other configurations and in a wide range of colours. For further information, please contact your nearest Clipsal Sales Representative. 2.0 Description The Clipsal Series is a range of high quality, two-wire, push button electronic time delay switches with remote control and override off facilities. The product is designed to control lighting and other loads to prevent them from being left on unnecessarily. Significant energy savings can result when used for staircase, hallway, classroom and similar applications. The unit has a powerful 10AX switching capability, and is suitable for a wide range of load types, including incandescent, inductive and fluorescent loads*. 3.0 Features State of the art low current consumption 2 wire design Time setting selection from 15 seconds to 254 minutes Timing accuracy ±8% Remote control capability, using remote wired momentary action switches 10AX switch load rating Suitable for a wide range of load types: Incandescent (tungsten filament) lamps 240V Halogen / Dichroic Lamps Low voltage downlights using electronic transformers Low voltage downlights using iron-core transformers Fluorescent Lighting s* Compact Fluorescent Light s* LED Lighting s* Small Motor s (limited to 2A) Available in a range of plate styles and colour variants Suitable for new installations or retro-fit applications Complies with Australian Standards * Two-Wire devices may require power factor correction capacitors to be fitted, else otherwise a 31CAP Correction Device to be installed to ensure correct operation. Refer to the Special s section of this instruction manual for more information. 4.0 Important Warnings Two or more 2-Wire Timers cannot be connected in parallel or series to control the same load from two different locations. If the timer is required to be controlled form multiple locations, please use the remote wiring facilities provided. If multiple timers are required to be connected in parallel, please use the equivalent 3-Wire product (3). It is illegal for persons other than an appropriately licenced electrical contractor or other persons authorised by legislation to work on the fixed wiring of any electrical installation. Penalties for conviction are severe! Copyright Clipsal Australia Pty Ltd 3 of 8

5.0 Timer Control 5.1 Push Button Control The built in push button has the following functions: Pressing the button when the load is off will initiate the timer and turn the load on. The load will automatically switch off when the timer expires. The amount of time is controlled by the timer settings on the rear of the unit (delay-to-off type timer). Pressing the button at any time when the load is on during the timer interval will cancel the timing and set the load to off. To restart the timer when the load is already on, simply perform consecutive turn-on and turn-off functions (see Important Notes below). 5.2 Indicator Function The built in light indicator is used to indicate the status of the load. The indicator will be on when the load is off The indicator will be off when the load is on. 5.3 Remote Operation The unit can respond to one or more remote wired momentary switch inputs. The unit will respond to the remote switch inputs in exactly the same way as if pressing the button on the front of the unit. IMPORTANT NOTES: The load cannot be turned on for the warm-up time (10 seconds) after power is applied to the device (e.g. power failure/return, initial installation, replacement of the globe). Wait 10 seconds after power up before pressing the button. Occasionally, consecutive button presses <0.5seconds apart may not be registered, and the load may not turn on as expected. Should this occur, wait 5 seconds and then press the button again to turn on the load. 6.0 Wiring Diagrams 6.1 Local Operation For most normal applications, where operation from the local push button is required only, the timer is wired as shown in the figure below. 6.2 Remote Operation Additional switches can be installed in parallel, allowing the timer to be activated from one or more remote locations. Neutral Neutral Remote NOTE: The remote switch wiring must be rated for 240V a.c. The sum of cable lengths used to connect the remote switches must not exceed 100m. Remote switches MUST be Normally Open momentary operation type switches. 4 of 8 Copyright Clipsal Australia Pty Ltd Remote Remote Switches Momentary Action

7.0 Special s 7.1 Product Selection Be sure to select the appropriate product to suit your application: The Series is a 2 wire (does not require neutral connection), but can only switch a limited range of load types without special consideration. The 3 Series is a 3 wire device (requires neutral connection to operate) capable of switching a wide range of load types. Catalogue Number Neutral Required Maximum * 31CAP Required for some Types NO 10AX YES 3 YES 10AX NO * Please refer to Technical Specifications for further information about compatible load types. 7.2 Handling Special s SMALL LOADS (<5W) The product can only drive loads greater than 5W. If you wish to drive a smaller load, the 31CAP Correction Device is required to be fitted in parallel with the load. For example: when driving a single contactor, be sure to use the 31CAP. LOADS WHICH ARE SENSITIVE TO LEAKAGE CURRENTS The is a two wire device. Two wire devices draw their power through the load. If this device is used in conjunction with a load which cannot provide enough continuous load current in the off-state, or the load is sensitive to a high off-state leakage current (for example: relays, contactors, various loads with built-in electronic control etc.) a 31CAP Correction Device must be connected in parallel with the load. SMALL (NON-POWER FACTOR CORRECTED) FLUORESCENT LOADS When a 31CAP is fitted, some small non-power factor corrected fluorescent loads may be controlled using the. Success varies from manufacturer to manufacturer. Recommend testing before installation. Installation must be compliant with local wiring rules. Neutral 31CAP 31CAP Correction Device Please note the 3 is a three wire device, and switches the load using an internal relay. Power is not drawn through the load and so the 31CAP is not required. Copyright Clipsal Australia Pty Ltd 5 of 8

8.0 Timer Settings WARNING: For safety reasons the setup should be performed with the timer isolated from the mains supply. 8.1 Timer Adjustment Settings The timer setting is achieved by the use of an 8 way micro switch. The switch is accessible from the back of the unit through a window in the enclosure. The functions of the individual switches are presented on the adjacent diagram. Timer Range Selection The following two ranges are available: Range Range Switch Minimum Setting Maximum Setting Long ON (GREEN) 2 minutes 4 hours & 14 minutes (254 minutes) Short OFF (RED) 15 seconds 31 minutes & 45 seconds Short Range Range Switch (No. 1) is switched in the direction of RED arrow. Time can be set via switches 2 to 8 from 15 seconds up to 31 minutes and 45 seconds. The achievable settings are multiples of 15 seconds (15 sec, 30 sec, 45 sec etc.) Long Range Range Switch (No. 1) is switched in the direction of GREEN arrow. Time can be set via switches 2 to 8 from 2 minutes up to 4 hours and 14 minutes. The achievable settings are multiples of 2 minutes (2 min, 4 min, 6 min etc.). The switches 2 to 8 are used to add specific time intervals to the total time delay. Every switch is marked with the two Time Interval values by which the individual switch contributes to the total time interval when turned on. The Time Interval value marked in GREEN is added if the Long Range is selected by the Range Switch. The Time Interval value marked in RED is added if the Short Range is selected by the Range Switch. 2min. 4min. 8min. 16min. 32min. 64min. 128min. 15sec. 30sec. 1min. 2min. 4min. 8min. 16min. RANGE 8.2 Example Settings ON LONG Example 1: Required Time Delay is 6 minutes and 30 seconds (6.5 minutes). OFF SHORT Initially set all the switches to OFF position. Total time set is 4 min + 2 min + 30 sec = 6.5 min As 6.5 minutes setting is lower than the maximum setting for the Short Range, set the Range Switch to Short Range (in the direction of the RED arrow). The highest time value for an individual switch lower than 6.5 is 4. Set the switch 4 minutes ON. Remaining time required is 6.5-4 = 2.5 minutes. The next highest value lower than 2.5 is 2 minutes Set the 2 minutes switch ON. The remaining time required is 6.5-4 - 2 = 0.5 minutes. Set the 30 seconds switch ON. 2min. 4min. 8min. 16min. 32min. 64min. 128min. Example 2: Required Time Delay is 3 hours 15sec. 30sec. 1min. 2min. 4min. 8min. 16min. RANGE and 20 minutes. ON LONG Initially set all the switches to OFF position. Calculate the total Time Delay required in minutes: 3 x 60 + 20 = 200 minutes. GREEN: 2min. 4min. 8min. 16min. 32min. 64min. 128min. RED: 15sec. 30sec. 1min. 2min. 4min. 8min. 16min. RANGE ON LONG (Green) 8 7 6 5 4 3 2 1 As 200 minutes setting is higher than the maximum setting for the Short Range, set the Range Switch to Long Range (in the direction of the GREEN arrow). OFF Time Intervals SHORT (Red) 6 of 8 Copyright Clipsal Australia Pty Ltd Range OFF SHORT Total amount of time delay set is 3 hours and 20 min = 200 min. = 128 min + 64 min + 8 min

9.0 Electrical Specifications Parameter Value Nominal Operating Voltage 220-240V~ Nominal Operating Frequency 50Hz Maximum Current 10AX Minimum Current 20mA Maximum Off-State Leakage Current 3mA Compatible s* Compact Fluorescent Lamps LED Lighting * Certain loads may require special handling (Power Factor Correction Capacitor or 31CAP to be fitted). Refer Special s section. Incandescent lamps Halogen 240V lamps Low voltage lighting with electronic transformers Low voltage lighting with iron-core transformers Fluorescent Lighting Small Motor s (Maximum 2A) Timer Range 15 seconds 254 minutes Timer Accuracy ± 8% Warm-Up Time 10 seconds maximum Power-Up Status OFF Operating Temperature Range 0 to 40 C Operating Humidity Range 10 to 90% R.H. Mounting Centres 84mm Australian Pattern Plate Safety Compliances AS/NZS3100, AS/NZS3133 EMC Emission Compliance AS/NZS CISPR15 Specifications Typical @ 240V~, 25 o C No User Serviceable Parts Inside WARNING: Operation outside of these specifications may result in unexpected behaviour, or even product failure. Timer accuracy may be affected by voltage, temperature and humidity. Warranty may be voided when controlling any incompatible load types as determined by Clipsal Australia. Copyright Clipsal Australia Pty Ltd 7 of 8

10.0 Warranty Statement 1. The benefits conferred herein are in addition to, and in no way shall be deemed to derogate; either expressly or by implication, any or all other rights and remedies in respect to the Clipsal Product, which the consumer has under the Commonwealth Trade Practices Act or any other similar State or Territory Laws. 2. The warrantor is Clipsal Australia Pty Ltd of 33-37 Port Wakefield Road, Gepps Cross, South Australia 5094. With registered offices in all Australian states. 3. This Clipsal product is guaranteed against faulty workmanship and materials for a period of two (2) years from the date of installation. 4. Clipsal Australia Pty Ltd reserves the right, at its discretion, to either repair free of parts and labour charges, replace or offer refund in respect to any article found to be faulty due to materials, parts or workmanship. 5. This warranty is expressly subject to the Clipsal product being installed, wired, tested, operated and used in accordance with the manufacturer s instructions. 6. All costs of a claim shall be met by Clipsal Australia Pty Ltd, however should the product that is the subject of the claim be found to be in good working order all such costs shall be met by the claimant. 7. When making a claim the consumer shall forward the Clipsal product to the nearest office of Clipsal Australia Pty Ltd with adequate particulars of the defect within 28 days of the fault occurring. The product should be returned securely packed, complete with details of the date and place of purchase, description of load, and circumstances of malfunction. Clipsal Australia Pty Ltd clipsal.com A member of Schneider Electric Contact us: clipsal.com/feedback National Customer Care Enquiries: Tel 1300 2025 25 Fax 1300 2025 56 Clipsal Australia Pty Ltd reserves the right to change specifications, modify designs and discontinue items without incurring obligation and whilst every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct, no warranty is given in respect thereof and the company shall not be liable for any error therein. Clipsal Australia Pty Ltd. The identified trademarks and copyrights are the property of Clipsal Australia Pty Ltd unless otherwise noted. F1178/04 CLIPCOM 21861 August 2010