InterSeptor Centrifugal Separators Operating & Maintenance Manual

Similar documents
INFINITY FLUIDS CORPORATION

Niles Steel Tank Hot Water Generator Installation and Operation Manual

In-Line Air Separators

SECTION AIR COMPRESSORS AND ACCESSORIES

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

ACT Cartridge Dust Collector

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

SECTION STEAM CONDENSATE PUMPS

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

569, 570, 571, 572 Series

569, 570, 571, 572 Series

PLEASE DO NOT DISCARD THE ATTACHED DOCUMENT IS NECESSARY FOR THE INSTALLATION OF YOUR GREASE TRAP.

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

STORAGE TANK INSTALLATION and OPERATION MANUAL

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

1.1 This section applies to air handling units for HVAC Systems.

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

LC Series - Light Commercial Pump Station Installation and Operation Manual

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Downtime Instructions

OWNERS GUIDE TO INSTALLATION AND OPERATION

cooling tower downtime instructions

568X, 587X, 588X Series

Noncycling Refrigerated Air Dryers Range AD 10 to AD 4000

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

4-1 1 / 2 " Tees / 2 " hole saw w/ 1/4" drill bit / 2 " Male slip plugs

ENERVEX VHX VORTEX HEAT RECOVERY CENTER

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Phoenix C4XE - Membrane Based Portable Lube and Hydraulic Oil Purifier Cart For use in Hazardous Duty Locations.

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

TM Series. Induced Draft, Counter Flow Optional Accessories

TECHNICAL. Series 18. Pump Packages

IRRIGATION EQUIPMENT LTD. The Perfect Solution for Water Filtration and Irrigation Problems

Full-line Product Overview

BuildingName The Description of the Project P DOCUMENTS

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

489G DESCRIPTION CAST IRON UNITS BRONZE UNITS 316 STAINLESS STEEL UNITS. Maintenance. General Safety Information for 12 Volt DC Power

DOMESTIC WATER HEATER OIL FIRED

MARLOW PUMPS RECIRCULATION

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Revitalize Building Mechanical Systems (4619)

TITAN FLOW CONTROL, INC.

INSTALLATION & OPERATING INSTRUCTIONS

GIRTON CABINET WASHER MODEL 794A

INSTALLATION OPERATION MAINTENANCE

PIPING SYSTEM EQUIPMENTS

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

Liquid Drainers LIQUID DRAINERS

Encyclon Inc. Cyclonic Filtration Systems

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

GOLF TECHNICAL BULLETIN

Operation & Maintenance Manual

VTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories...

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

INSTALLATION INSTRUCTIONS WARRANTY

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

4 route 147, C.P.33 Coaticook, Qc J1A 2S8

HEAT OF COMPRESSION DESICCANT AIR DRYERS. DHC Series

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

RCF Closed Circuit Cooling Towers RCC Evaporative Condensers

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING.

ClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV

CMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED. Models: CMO32 CMO50

INSTALLATION INSTRUCTIONS

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

Elite Primer Baldor Series External Pond Pump

INSTALLATION INSTRUCTIONS

Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Model T Professional Series 3/4HP 2 YEAR WARRANTY SEWAGE PUMP

Operations and Maintenance Manual

Allcan TM Installation Manual

dualarm Vertical In-Line Pumps

SECTION CENTRIFUGAL WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Paragon. Induced Draft, Counter Flow Optional Accessories

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

PrecisionTemp Shower-Mate

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Hydrotherapy Jets (Remote Water Quality System)

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

GLOBAL FLOW PRODUCTS

RSIF Power Venter. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

SECTION PLUMBING EQUIPMENT

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

Transcription:

General Information: This manual was prepared to assist in the installation, operation, and maintenance of PEP ICS centrifugal separator systems. For immediate response to questions not covered in this manual please contact your PEP representative or call the factory at 800-24-FILTERS. Description: The PEP ICS Separator has no moving parts, requires no spare parts inventory, and contains no filter media to clean or change. The flow-through design allows for continuous operation while process liquid is pumped through the ICS separation chamber. The PEP ICS Separator is ideal for separating solids from cooling tower water, process water, and other applications requiring separation of liquids from solids. PEP InterSeptor Centrifugal Separator models are referred to by the inlet/outlet size. For example, the 1 model separator has one-inch inlet and outlet fittings; the 2 model separator has two-inch inlet and outlet fittings, and so forth. Principle of Operation: Liquid enters the ICS cylindrical separation chamber through a tangential entry port located near the ICS Separator top. The tangential entry port induces a spinning motion to the liquid / suspended particulate medium. The heavier than liquid particulates are forced to the outside of the cylindrical separation chamber wall, where they settle to the bottom of the separator and accumulate in what is referred to as the solids collection chamber. This chamber is purged periodically to remove the collected solids. The standard purge is a manual operation. A purge valve (not supplied) sized to match the drain must be installed before placing the ICS into operation. Automatic purging is available as a factory installed option. Clean water flows up the center vortex tube and exits the ICS Separator. 704-662-3133 (Outside USA) 1 of 5 Fax 704-662-3155

Installation: The following items are not included with Standard ICS units, but are required for operation: Inlet/outlet valves Spool pieces Air relief valve Pressure gauges PEP InterSeptor Centrifugal Separators (ICS) can be installed in several different ways: 1. Free standing on integral base plate with anchor provision (on 3 inch units and smaller) 2. Leg assemblies with anchor provision (on 4 units and above) 3. Wall mounting (with optional wall mounting kit) 4. Special 45 angle for restrictive vertical space limitations It is recommended to install a valve on the inlet and outlet of the ICS Separator in the event it becomes necessary to isolate the unit from the process. For ICS units 6 and larger, it is further recommended to install a spool piece between the valves and separator inlet and outlet. This will facilitate installation and removal of the separator from the process piping. The valves and spool pieces should be sized to match the ICS separator inlet and outlet diameters. For ease of installation, allow about three feet of clearance around the separator. Check for any applicable local, state and federal codes. An adequate foundation or other support means must be provided for the ICS unit. Three inch and smaller separators are provided with an integral base mounting plate with holes to accommodate floor mounting. Separators larger than three inches have four legs with a provision for floor mounting. Check inlet, outlet and purge nozzles for any foreign objects that may have entered the ICS during shipment, storage or installation. When connecting inlet and outlet piping, use appropriate hardware to match inlet & outlet diameters. Flange bolts and gaskets are not included with separator. ICS separators are typically installed downstream of a pump system. To assure sufficient velocity for adequate liquid/solids separation, the inlet pressure should be in the range of 3 to 10 psig greater than the ICS discharge pressure. 704-662-3133 (Outside USA) 2 of 5 Fax 704-662-3155

For adequate separator performance, the PEP ISC Separator system should be installed no more than 5 feet above or 8 feet below the sump, water basin, or tower water level. Note: When the separator is installed above basin level, a check valve must be installed in the lowest point of the pump suction line (below water level). Piping and Valves The PEP ICS Separator inlet is located on the side, near the top. The separator outlet is located on the top. On 3 and smaller units, the purge connection is located on the side, near the bottom. On 4 and larger units, the purge connection is located on the bottom. The ½ and ¾ models have threaded npt nipples for connection to the inlet and outlet. All larger models have 150 lb. Raised face flange connections. The separator outlet piping should be plumbed to merge with the flow in the piping system, not against it. Pipe size must be the same as the inlet and outlet separator fittings to maintain proper flow. PEP will furnish typical installation drawings upon request. Connecting the drain line: To assure proper collected solids drainage, it is important to match the drainpipe diameter with the diameter of the drain fitting on the ICS Separator. Refer to the dimension table on the drawing in this manual (Purge Outlet B ) for the drain size of your particular ICS Separator. Maintenance / Purging: The ICS Separator requires periodic purging. Otherwise, accumulation of separated solids will overfill the collection chamber and system performance will be diminished. To assure sufficient purge pressure, there should be a minimum 5 psig at the separator outlet. Slope the purge line continuously downward to assure complete drainage. Three purge options are available: 1. Manual purge: A valve on the collection chamber is opened by hand periodically to purge solids from the chamber (standard on all ICS Separators). 2. Automatic purge: PEP offers a motorized ball valve that will automatically open the purge drain at a field selectable time interval. Once every 4 hours is typical. The purge duration is also field selectable. The ICS Separator is continuously on line, even during the purge cycle. 704-662-3133 (Outside USA) 3 of 5 Fax 704-662-3155

3. Continuous purge: The purge line valve is open a small amount and water continuously purges the system to keep it clean. Note: It is recommended to purge the unit while in operation. This assures a strong purge for best evacuation of the solids collection chamber. Winter Operation: If exposed to freezing temperatures, the potential exists for the separator and related exposed piping to freeze. Damage to piping and separator may result. Continuous operation will minimize the freeze risk however, it is recommended to protect the piping and separator in some manner (locate indoors or apply heat tracing and insulation to exposed all surfaces). If the unit is idle for periods of time, it is recommended to drain the ICS Separator and pump. Startup Procedure: Before startup, always check the immediate area and remove any debris that may interfere with moving pump parts or cause possible injury to personnel. If the unit is supplied with the optional system matched pump / pre-strainer combination, check the pre-strainer basket prior to every startup for large solids that may damage ~ pump or restrict it's flow. With power turned off and locked out at the main circuit breaker, turn the pump shaft by hand to make sure that the impeller turns freely. Check any isolation or service valves to make sure they are in the full open position so as not to restrict the suction or discharge. Quickly turn the pump motor on and then off, taking note of the rotation of the pump shaft. Make sure the shaft is rotating in the direction required by the pump. If the motor rotates backward, have an electrician switch the phases and repeat this procedure. Open the manual air relief valve on the top of the separator. Start the pump and allow the separator vessel to fill. Once the air is purged, close the valve. Check the pump motor current draw to make sure it is not drawing more than the rated current. Refer to the motor nameplate for the current rating and voltage requirement. Check the system piping and repair any leaks. Open the air vent again on top of the separator. If air is vented, it could be caused by a small leak in the pump inlet 704-662-3133 (Outside USA) 4 of 5 Fax 704-662-3155

suction piping. Make sure the pre-strainer lid is securely fastened and the gasket is not pinched. With liquid flowing through the separator, check and record the inlet and outlet pressure gauge readings. Also record the pressure differential. The pressure differential (psid) is the difference between the outlet and inlet pressure readings. For adequate separator performance, the pressure drop should be in the range of 3 to 10 psid. Note: The separator size is determined by the flow rate through the separator. If the separator is too large for the flow, insufficient pressure differential will result and negatively affect separator performance. The following table indicates recommended flow ranges for PEP InterSeptor Centrifugal Separators (ICS). Optimal pressure differential is realized when running the separator within the prescribed operating flow range. Model InterSeptor Centrifugal Separators Inlet/Outlet Diameter Purge Outlet Diameter Flow Range (gpm) ICS2-0050 ½ 1 10-20 ICS2-0075 ¾ 1 15-35 ICS2-0100 1 1 30-60 ICS2-0125 1-1/4 1 50 110 ICS2-0150 1-1/2 1 80-150 ICS2-0200 2 1 120-210 ICS2-0300 3 1 195-330 ICS2-0400 4 1-1/2 280-500 ICS2-0500 5 1-1/2 320-750 ICS2-0600 6 1-1/2 690 1350 ICS2-0800 8 1-1/2 1000 2225 ICS2-1000 10 2 1500 3500 ICS2-1200 12 2 2000-5000 704-662-3133 (Outside USA) 5 of 5 Fax 704-662-3155