5000TC Series Toroidal (Electrodeless) Conductivity Sensors. Specification. Overview. Features. Description /00 Page 1 of 8

Similar documents
Toroidal (Electrodeless) Conductivity Sensors Series 5000TC Specifications

Conductivity Product Name Part No.

MEAS CAL ALARM WASH CONF APT4000 TC

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

Toroidal Conductivity Transmitters Series APT4000 Specifications

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

Figure 1 DirectLine DL423 Sensor. Description, continued

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Smart Sensors and Analytical Instruments Honeywell Solutions for Analytical Measurement and Control

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Interactive Catalog Replaces Catalog Pages

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

Intrinsically Safe Transmitters, Option Code 2n

Hydrazine Analyzer Series 2171 Specifications

Figure 1 DirectLine DL423 Sensor. Description, continued

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

Durafet Non-Glass ph Electrodes Specifications

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES


Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

Model Q45P/R. ph/orp Monitor...

HOA6480 Series Barcode Sensor Infrared Products

Interactive Catalog Replaces Catalog Pages

Linear Current Sensors

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

CONDUCTIVITY SPECIFICATIONS TEMPERATURE SPECIFICATIONS. PDFINFO p a g e

WARNING MISUSE OF DOCUMENTATION

V-Basic Standard V15 Series

SX Series Silicon Pressure Sensors 0 psi to 1 psi to 0 psi to 150 psi

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

Model Q45P/R. ph/orp Monitor...

Installation Instructions for the LM Series MCU (Microcontroller Unit) LCD Hour Meter

FR/SR Series. Full Sized, Sealed Rocker Switches SR SERIES FR SERIES DESCRIPTION FR SERIES SR SERIES FEATURES FR SERIES SR SERIES

MICRO SWITCH NT Series

Inductive Conductivity

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

High Temperature Industrial VRS Magnetic Speed Sensors

Installation Instructions for the 600 Series Optical Encoders

MICRO SWITCH GSX Series

General Purpose Industrial VRS Magnetic Speed Sensors

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

Quick Start Guide for the Limitless Series WGLA Limit Switch used in conjunction with the Limitless WPMM Series ISSUE WARNING

HIH-4000 Series Humidity Sensors

Micropower Omnipolar Digital Hall-Effect Sensor ICs

HIH-4602-L Series Humidity Sensors

Quadrature Speed and Direction Sensors

ph-orp Product Name Part No.

CONTACTING CONDUCTIVITY BOILER SENSORS Instruction Manual

Chemtrol Thermoplastic Flow Solutions. PVC, CPVC, PP, and PVDF Piping Solutions. Chemtrol is a brand of

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

Potential Applications

HIH-4010/4020/4021 Series Humidity Sensors

The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits.

HIH-5030/5031 Series Low Voltage Humidity Sensors

ENDURANCE Conductivity Sensors

Installation Instructions for the

MICRO SWITCH GLL Series

MICRO SWITCH NT Series

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

Miniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Magnetoresistive Sensor ICs. Nanopower Series. Datasheet

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

MICRO SWITCH V15W Series Watertight Miniature Switches

EMERGENCY STOP NEEDS 2015 CATALOG

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

Heavy Duty Pressure Transducers Line Guide

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

Sensors and Switches in Commercial Traction Elevators

Circuit Protector. GCP Series. Features. Electromagnetic Overcurrent Protection. Approvals. AC/DC Dual Voltage. Easily Identified ON/OFF Indicator

HIH-4030/31 Series Humidity Sensors

900 ControlEdge Remote Termination Panel (RTP) For Relay Outputs

Supply voltage (Vcc) Vcc reference to ground V Supply current: off on. Vcc = 5 V, T = 25 C [77 F] Vcc = 5 V, T = 25 C [77 F

Silica, Phosphate, Hydrazine Analyzers Series 2140 Specifications

1HP Series. Aerospace-Grade Pressure Switch High Pressure Series. precise, demanding requirements of aerospace and defense applications.

MICRO SWITCH BAF/DTF Series

HFX Fiber Optic Component 50 Mbps, 650 nm LED

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Durafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications

Table 1. Absolute Maximum Ratings. Characteristic. Magnetic flux. ma maximum ±670 ±600 ±670 ± ± ±0.150 ± , , +0.

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

Controllers, Indicators & Set Point Programmers

HIH-4602 A & C Series.

Installation Instructions for the

MICRO SWITCH BX/BX2 Series

Sethco MODEL P90 SEALLESS DRUM PUMPS. In Use The World Over. Sethco Division DRUM PUMP

TruStability Board Mount Pressure Sensors

AMR 4-Pin Quadrature Sensor Integrated Circuit

HPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Operating Temperature/Pressure Graphs: Flow Sensors

5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Transcription:

TC Series Toroidal (Electrodeless) Conductivity Sensors Overview The Honeywell TC toroidal (electrodeless) conductivity sensor measures the conductivity of solutions from.2 to millisiemens/cm. The sensors can be used for monitoring chemical concentration and salinity as well. The corrosion and fouling-resistant cells are available with a variety of mounting assemblies to ensure compatibility for applications in the chemical, food & dairy, refinery, pulp & paper, metal finishing and wastewater industries. 7-82-3-37 5/ Page 1 of 8 Specification Features Variety of material types to meet most application needs PEEK, PFA Teflon, PVDF, and Polypropylene. Increased cell reliability due to high chemical resistance and low friction factor in the materials of construction Flexibility of installations with four mounting types Immersion, Unionmount, Insertion/Removal, and Sanitary Temperature-compensated measurement with Pt ohm RTD Convenient for most applications 2 ft. cable standard 3A-approved materials of construction and clean-in-place fitting makes the sanitary type cells suitable for most sanitary applications. Figure 1 TC Convertible & Sanitary Sensors Description The Honeywell TC sensors are specifically designed for the monitoring of conductivity, chemical concentration, or salinity in difficult applications where coating, fouling, corrosion, or high temperatures/ pressures are a concern. The sensor s 1 ½ diameter bore minimizes rough surfaces to ensure that flow impedance is minimized. A Ω Pt RTD provides accurate temperature measurement to ensure proper temperature compensation. Two types of basic sensor forms are available with the Honeywell TC the convertible or sanitary style. Convertible Style The TC convertible style toroidal sensor includes both a ¾ and a ½ fitting to allow direct fastening to the end of a pipe for either immersion mounting or a union-mount adapter for a standard 2 pipe tee. The convertible style can also be insertion mounted into a 2 ball valve assembly. Convertible sensors are available in PEEK, PVDF, PFA Teflon, and Polypropylene materials. Sanitary Style The TC sanitary style toroidal sensor includes a clean-in-place style fitting and is constructed of 3A-approved materials. It has an integral 2 sanitary-mount flange which mates to Honeywell sanitary tee mounting hardware. The sanitary-style sensor includes a special cap and EPDM compound gasket. The gasket is also available separately for mounting to a 2 sanitary clamp-type ferrule or butt-weld tee. Sanitary sensors are available in PVDF, PFA Teflon, and Polypropylene materials. Sensing and Control, 11 West Spring Street, Freeport, Illinois 6132 Printed in U.S.A. Copyright Honeywell

Page 2 of 8 Dimensions for TC Sensors Figure 2 Dimensions for Sanitary Type Figure 3 Dimensions for Convertible Type

Page 3 of 8 Wetted Materials To simplify chemical resistance problems, these sensors are constructed so that only one material is wetted by the process. The wetted material is non-conductive to insure that the sensor is electrically isolated from the process fluid. The TC sensors are available in four different material types PEEK, PFA Teflon, Polypropylene and PVDF. PEEK (Polyetheretherketone) PFA Teflon (Perfluoroalkoxy Teflon) Polypropylene PVDF (PolyVinylidene Fluoride, also called KYNAR ) This material type is ideal for the broadest range of applications within the chemical, pulp & paper, and refinery industries. The only known materials to severely attack PEEK are very high concentrations of acids, such as nitric or sulfuric. It has a higher temperature capability than the Polypropylene or PVDF sensors. This material type is ideal for extremely corrosive applications, especially high concentrations of sodium hydroxide, nitric acid, sulfuric acid, or hydrofluoric acid. It has the highest temperature rating of the four sensor types. It is also ideal for applications which have a tendency to coat the sensor. This material type is ideal for wastewater applications where the temperatures and pressures are close to ambient and chemical compatibility is not a serious concern. This material type is one of the most rigid and abrasion-resistant materials. It has good chemical resistance to halogens, such as chlorine or bromine. It is ideal for applications which require higher pressure ratings, but do not have high temperatures, such as water treatment applications in the semiconductor industry. Specifications Common to All Cell Types Wetted Materials Operating Temperature Range PFA Teflon, Polypropylene, PVDF, or PEEK 1 C to 125 C (14 F to 257 F) Maximum Flow Rate 1 ft. (3 m) per second Measuring Range Temperature Compensator Sensor Cable Bore Size.2 to millisiemens/cm Pt Ω RTD 5 conductor (plus two isolated shields) cable with XLPE (cross-linked polyethylene) jacket; rated to C (32 F); 2 ft. (6 m) long 1.5 diameter,.4 hole Pressure/Temperature Limits: Sensor Only (no hardware) Polypropylene psi at 212 C (6.9 bar at C) PVDF psi at 248 C (6.9 bar at 12 C) PEEK psi at 32 F (13.8 bar at C) PFA Teflon psi at 32 F (13.8 bar at C)

Page 4 of 8 Mounting Types The TC sensors are available with a number of different mounting types. These include immersion mounting (CPVC or PVDF materials, also PVC junction box), union mounting (316 SS, CPVC or PVDF materials with optional 2 tee), sanitary mounting (316 SS 2 tee with heavy-duty clamp), or insertion/removal mounting (316 SS or CPVC material). Figure 4 Immersion Mounting Figure 5 Union Adapter Mounting Figure 6 Insertion/Removal Mounting Figure 7 Sanitary Mounting

Page 5 of 8 Basic Mounting Specifications* 3 2 CPVC Mounting Hardware (all Sensor Materials) NOTE: Rating limited by hardware material. -1 1 2 3 4 6 7 8 9 1112 O 316 Stainless Steel Sanitary Mounting Hardware** With Polypropylene Sensor 3 2 225 psig -1 1 2 3 4 6 7 8 9 1112 O 3 PVDF Mounting Hardware (all Sensor Materials) 316 Stainless Steel Sanitary Mounting Hardware With PVDF Sensor 3 2 NOTE: Rating limited by hardware material. 2-1 1 2 3 4 6 7 8 9 1112 o -1 1 2 3 4 6 7 8 9 1112 O 3 2 316 Stainless Steel Mounting Hardware PEEK and PFA Teflon PVDF NOTE: Rating limited by sensor material. Polypropylene -1 1 2 3 4 6 7 8 9 11121314 o 3 2 316 Stainless Steel Sanitary Mounting Hardware With PFA Teflon Sensor -1 1 2 3 4 6 7 8 9 11121314 o *Ratings for the above Honeywell sensor and mounting hardware combinations are based upon water service. More severe service may require a correction factor. Includes immersion mount, union adapter mount, and sanitary mount. Separate specifications are provided for the insertion/removal device. **Sanitary mounting hardware ratings are for 51451248-1 hardware using the 51451257-1 heavy duty sanitary clamp. Other hardware and clamp combinations may reduce the listed ratings.

Page 6 of 8 Insertion/Removal Mounting Specifications* Wetted Materials Plastic Hardware: Brass, CPVC, Teflon Valve Seats, Viton O-ring Seals Stainless Steel Hardware: 316 Stainless Steel, Teflon Valve Seats, Viton O-ring Seals Temperature Limits Plastic Hardware: 23 to 176 F (-5 to 8 C) unsupported if installed vertically; 23 F to 23 F (-5 C to 95 C) when supported with a bracket** Stainless Steel Hardware: 23 F to 23 F (-5 C to 95 C) supported or unsupported Pressure Limits Plastic Hardware: psi @ 9 C Stainless Steel Hardware: psi @ 9 C Net Hardware Weight Plastic Hardware: 7.5 lbs. (3.4 kg) Stainless Steel Hardware: 25 lbs. (11.3 kg) *These sensor/mounting hardware assembly temperature ratings are limited by the hardware material, maximum pressure, and whether the assembly is supported or unsupported. **The CPVC insertion/removal assembly must be supported with a bracket or strap if it is not installed vertically. 11 1 9 + 8 7 6 5 4 3 2 1 enter MEAS CAL ALARM CONF FM APPROVED CAL CONF ENTER APT TC Sup pl y/ Ou t p u t Toroidal Conductivity Sensor Figure 8 Honeywell APTTC Toroidal Conductivity Transmitter Figure 9 TC Wiring Diagram for APTTC Transmitter

Page 7 of 8 51-52-16-54 Issue 1 Toroidal Conductivity Cells Model Selection Guide Instructions Make one selection from Table I through IV A dot ( ) denotes unrestricted availability. Key Number I II III - - _ - _ KEY NUMBER Description Toroidal (Electrodeless) Conductivity Probe Selection Availability TC TABLE I Mounting No Mounting Assembly Material CPVC Pipe, PVC Junction Box 5145124-1 11 Type PVDF Pipe, PVC Junction Box 51451241-1 12 316 SS Union Adapter & Standard 2" Tee 51451242-1 21 316 SS Union Adapter Only 51451243-1 22 CPVC Union Adapter & Standard 2" Tee 51451244-1 23 CPVC Union Adapter Only 51451245-1 24 PVDF Union Adapter & Standard 2" Tee 51451246-1 25 PVDF Union Adapter Only 51451247-1 26 316 SS Sanitary 2" Tee & Heavy-Duty Clamp 51451248-1 31 316 SS Insertion/Removal Device 51451249-1 41 CPVC Insertion/Removal Device 514512-1 42 TABLE II Sensor No Sensor Material Convertible Polypropylene Sensor 51451251-1 1 a Type Convertible PVDF Sensor 51451252-1 2 a Convertible PEEK Sensor 51451253-1 3 a Convertible PFA Teflon Sensor 51451254-1 4 a Sanitary Polypropylene Sensor -1 5 b Sanitary PVDF Sensor 151-1 6 b Sanitary PFA Teflon Sensor 152-1 7 b TABLE III Future None ACCESSORIES 51451255-1 6-Conductor Interconnect Cable 51451256-1 6-Conductor Junction Box (comes standard with immersion hardware) 51451257-1 Spare Sanitary Clamp (standard with option 31 from Table I) 51451258-1 Spare Special Cap (standard with option 31 from Table I) 51451259-1 Spare Sanitary Gasket (standard with option 31 from Table I) RESTRICTIONS Restriction Available Only With Not Available With Letter Table Selection Table Selection a I 31 b I 31

Page 8 of 8 Warranty/Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Distributor : For more information, contact Honeywell sales at 1-8-343-228. Teflon is a registered trademark of Dupont KYNAR is a registered trademark of PennWalt Corporation Sensing and Control Honeywell 11 West Spring Street Freeport, IL 6132 7-82-3-37 Printed in USA www.honeywell.com/sensing