ENDURANCE Conductivity Sensors
|
|
- Christiana Green
- 6 years ago
- Views:
Transcription
1 Models 403 and 403VP Instruction Manual PN February 2001 ENDURANCE Conductivity Sensors Model 403 Model 403VP Sanitary Flange Sensors Sanitary Flange Sensors with Variopol Connector
2 ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount Analytical designs, manufactures, and tests its products to meet many national and international standards. Because these instruments are sophisticated technical products, you must properly install, use, and maintain them to ensure they continue to operate within their normal specifications. The following instructions must be adhered to and integrated into your safety program when installing, using, and maintaining Rosemount Analytical products. Failure to follow the proper instructions may cause any one of the following situations to occur: Loss of life; personal injury; property damage; damage to this instrument; and warranty invalidation. Read all instructions prior to installing, operating, and servicing the product. If this Instruction Manual is not the correct manual, telephone and the requested manual will be provided. Save this Instruction Manual for future reference. If you do not understand any of the instructions, contact your Rosemount representative for clarification. Follow all warnings, cautions, and instructions marked on and supplied with the product. DANGER HAZARDOUS AREA INSTALLATION This sensor is not Intrinsically Safe. or Explosion Proof. Installations near flammable liquids or in hazardous area locations must be carefully evaluated by qualified on site safety personnel. To secure and maintain an intrinsically safe installation, an appropriate transmitter/ safety barrier/sensor combination must be used. The installation system must be in accordance with the governing approval agency (FM, CSA or BASEEFA/CENELEC) hazardous area classification requirements. Consult your analyzer/transmitter instruction manual for details. Proper installation, operation and servicing of this sensor in a Hazardous Area Installation is entirely the responsibility of the user. Inform and educate your personnel in the proper installation, operation, and maintenance of the product. Install your equipment as specified in the Installation Instructions of the appropriate Instruction Manual and per applicable local and national codes. Connect all products to the proper electrical and pressure sources. To ensure proper performance, use qualified personnel to install, operate, update, program, and maintain the product. When replacement parts are required, ensure that qualified people use replacement parts specified by Rosemount. Unauthorized parts and procedures can affect the product s performance and place the safe operation of your process at risk. Look alike substitutions may result in fire, electrical hazards, or improper operation. CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY The wetted sensor materials may not be compatible with process composition and operating conditions. Application compatibility is entirely the responsibility of the user. Ensure that all equipment doors are closed and protective covers are in place, except when maintenance is being performed by qualified persons, to prevent electrical shock and personal injury. Rosemount Analytical Inc. Uniloc Division 2400 Barranca Parkway Irvine, CA USA Tel: (949) SS-SE Nov Rosemount Analytical Inc. 2000
3 MODEL 403/403VP SECTION 1 SPECIFICATIONS SECTION 1. SPECIFICATIONS SENSOR SPECIFICATIONS SPECIFICATIONS MODEL 403 MODEL MODEL 403VP MODEL 403VP-14 Cell Constants 0.01/cm, 0.1/cm, 1.0/cm 10.0/cm, 0.01/cm, 0.1/cm, 1.0/cm 10.0cm Process Connection sanitary flange (Tri-clover) sanitary flange (Tri-clover) sanitary flange (Tri-clover) sanitary flange (Tri-clover) -20: 1-1/2 in. -20: 1-1/2 in. -20: 1-1/2 in. -20: 1-1/2 in. -21: 2 in. -21: 2 in. Electrode/Insulator titanium/kel-f graphite/epoxy titanium/kel-f graphite/epoxy Other Wetted Materials 316 SS and EPDM 316 SS and EPDM 316 SS and EPDM 316 SS and EPDM Temperature Element stnd: Pt 1000 stnd: Pt 1000 stnd: Pt 1000 stnd: Pt : Pt : Pt : Pt : Pt 100 Temperature Range C ( F) C ( F) C ( F) C ( F) Sensors tolerate steam Sensor is not suitable for Sensors tolerate steam Sensor is not suitable for sterilization up to 135 C steam sterilization sterilization up to 135 C steam sterilization (275 F) (275 F) Maximum Pressure 250 psig (1825 kpa) 250 psig (1825 kpa) 250 psig (1825 kpa) 250 psig (1825 kpa) Integral Cable Length stnd: 10 ft (3.1 m) stnd: 10 ft (3.1 m) Sensor has VP 6.0 connector. Sensor has VP 6.0 connector. -50: 50 ft (15.2 m) -50: 50 ft (15.2 m) Mating cable is available in Mating cable is available in 10 ft (3.1 m) and 50 ft (15.2 m) 10 ft (3.1 m) and 50 ft (15.2 m) lengths. lengths. NOTE: All wetted materials used in Models , -12, and -13, and Models 403VP-11, -12, and -13 are FDA-compliant. Materials used in Model and 403VP-14 are not FDA-compliant. RECOMMENDED CELL CONSTANT AND INSTRUMENT COMBINATIONS FOR MODEL 403 AND 403VP SENSORS CELL CONSTANT 0.01/cm 0.1/cm 1.0/cm 10.0/cm 1054B LC.02 to 20 µs/cm 1054B R.02 to 20 µs/cm 0.2 to 200 µs/cm 2.0 to 2000 µs/cm 200 to 20,000 µs/cm 1054B DC.02 to 20 µs/cm 0.2 to 200 µs/cm 2.0 to 2000 µs/cm 200 to 20,000 µs/cm 1054B C Not recommended 10 to 2000 µs/cm 50 to 20,000 µs/cm 500 to 20,000 µs/cm 1055C.02 to 20 µs/cm 0.2 to 200 µs/cm 2.0 to 2000 µs/cm 200 to 20,000 µs/cm 54e C.02 to 20 µs/cm 2.0 to 200 µs/cm 20 to 2000 µs/cm 200 to 20,000 µs/cm 1181C Not recommended 10 to 2000 µs/cm 50 to 20,000 µs/cm 500 to 200,000 µs/cm 2081C Not recommended 10 to 2000 µs/cm 50 to 20,000 µs/cm 500 to 200,000 µs/cm 3081C/81C.02 to 20 µs/cm 2.0 to 200 µs/cm 20 to 2000 µs/cm 4081C.02 to 20 µs/cm 2.0 to 200 µs/cm 20 to 2000 µs/cm 1
4 MODEL 403/403VP SECTION 1 SPECIFICATIONS ORDERING INFORMATION AND ACCESSORIES Model 403 Sanitary Flange Sensors: The base 403 sensor is compatible with the Solu Comp, Solu Comp II (1055C), 1054B LC, 1054B R, 1054B DC, 54e C, 81C, 3081C, and 4081C instruments and can be made compatible with other instruments by using code -54 option. MODEL 403 SANITARY FLANGE SENSOR CODE Cell Constant (required selection) /cm /cm /cm /cm CODE Sanitary Fitting (required selection) /2 inch Stainless steel sanitary fitting 21 2 inch Stainless steel sanitary fitting (not available with codes -13 and -14) CODE Temperature Compensation (optional selection) For 1054B LC, 1054B R, 1054B DC, 54e C, 81C, 3081C, 4081C, and 1055C (Pt 1000 RTD) 54 For 1054C, 1054A C, 1054B C, 2054C, and 2081C (Pt 100 RTD) CODE Additional Option (optional selection) 36 Extended insertion length (6 in. from inside face of flange to end of sensor, available with option -11 only) 50 Integral 50 ft (15.2 m) cable length EXAMPLE Model 403VP Sanitary Flange Sensors: The base 403VP sensor is compatible with the Solu Comp, Solu Comp II (1055C), 1054B LC, 1054B R, 1054B DC, 54e C, 81C, 3081C, and 4081C instruments and can be made compatible with other instruments by using code -54 option. MODEL 403VP SANITARY FLANGE SENSOR CODE Cell Constant (required selection) /cm /cm /cm /cm CODE Sanitary Fitting (required selection) /2 inch Stainless steel sanitary fitting 21 2 inch Stainless steel sanitary fitting (not available with codes -13 and -14) CODE Temperature Compensation (optional selection) For 1054B LC, 1054B R, 1054B DC, 54e C, 81C, 3081C, 4081C, and 1055C (Pt 1000 RTD) 54 For 1054C, 1054A C, 1054B C, 2054C, and 2081C (Pt 100 RTD) CODE Additional Option (optional selection) 36 Extended insertion length (6 in. from inside face of flange to end of sensor, available with option -11 only) 403VP EXAMPLE * NOTE: A Variopol (VP) connector cable must be purchased separately. See ACCESSORIES. 2
5 MODEL 403/403VP SECTION 1 SPECIFICATIONS ACCESSORIES PART NUMBER DESCRIPTION Connecting cable (terminated), for connecting junction box to analyzer. Cable does not mate with 402VP (Variopol) sensors. Specify length Cable with mating Variopol connector, 10 ft (3 m) Cable with mating Variopol connector, 50 ft (15.2 m) Connecting cable (unterminated), for connecting junction box to analyzer. Specify length Cable extension junction box SS-1 Conductivity Standard, 1409 µs/cm at 25 C, 1 quart (945 ml) SS-1A SS-5 SS-5A SS-6 SS-6A SS-7 SS-7A Conductivity Standard, 1409 µs/cm at 25 C, 1 gallon (3785 ml) Conductivity Standard, 1000 µs/cm at 25 C, 1 quart (945 ml) Conductivity Standard, 1000 µs/cm at 25 C, 1 gallon (3785 ml) Conductivity Standard, 200 µs/cm at 25 C, 1 quart (945 ml) Conductivity Standard, 200 µs/cm at 25 C, 1 gallon (3785 ml) Conductivity Standard, 5000 µs/cm at 25 C, 1 quart (945 ml) Conductivity Standard, 5000 µs/cm at 25 C, 1 gallon (3785 ml) 3
6 MODEL 403/403VP SECTION 2 INSTALLATION UNPACKING AND INSPECTION SECTION 2. INSTALLATION Inspect the shipping container. If it is damaged, contact the shipper immediately for instructions. Save the box. If there is no apparent damage, unpack the container. Be sure all items on the packing list are present. If items are missing, notify Rosemount Analytical immediately. SENSOR DIMENSIONS INCH MILLIMETER DWG. NO. REV B 4 FIGURE 2-1. Model 403 Sensor Dimensional Drawing
7 MODEL 403/403VP SECTION 2 INSTALLATION INCH MILLIMETER DWG. NO. 4403VP01 REV. C FIGURE 2-2. Model 403VP Sensor Dimensional Drawing 5
8 MODEL 403/403VP SECTION 3 WIRING DIAGRAMS AND CABLE PREPARATION SECTION 3. WIRING DIAGRAMS AND CABLE PREPARATION CABLE 1. Model 400 The sensor can be connected to the analyzer through a remote junction box. Both factory-terminated and unterminated connecting cable are available. PN Factory-terminated cable PN Unterminated cable. To terminate cable, see instructions in Figure Model 400VP The sensor has a Variopol 6-pin connector. Two lengths of cable terminated with a mating connecter are available. PN ft (3 m) cable with mating Variopol 6.0 connector PN ft (15 m) cable with mating Variopol 6.0 connector For longer cable runs, use a junction box (PN ) and extension cable. PN Factory-terminated cable PN Unterminated cable. To terminate cable, see instructions in Figure TABLE 3-1. Colors and Functions of Wires NAME COLOR FUNCTION Drive Gray Connects to outer electrode Drive Common Clear Shield for gray lead; coaxial with gray lead Receive Orange Connects to inner electrode Receive Common Clear Shield for orange lead; coaxial with orange lead RTD In Red RTD in RTD Sense White with red stripe RTD RTD sense RTD Return White RTD return RTD Shield Clear Shield for all RTD lead wires WIRING DIAGRAMS MODEL 400 SENSORS WITH JUNCTION BOX GRAY GRAY NOTE: TERMINALS IN JUNCTION BOX ARE NOT NUMBERED. 6 FIGURE 3-1. Sensor-Mounted Junction Box Wiring FIGURE 3-2. Model 2081C Wiring
9 MODEL 403/403VP SECTION 3 WIRING DIAGRAMS AND CABLE PREPARATION FIGURE 3-3. Model 81C Wiring FIGURE 3-4. Model 3081C & 4081C Wiring FIGURE 3-5. Model 1054C Wiring FIGURE 3-6. Model 1054BLC Wiring FIGURE 3-7. Model 1054BDC & 1054BR Wiring 7
10 MODEL 403/403VP SECTION 3 WIRING DIAGRAMS AND CABLE PREPARATION FIGURE 3-8. Model 1054AC & 2054C Wiring CUT OFF WHITE/RED WIRE AND CLEAR SHIELD WIRES FROM SENSOR CABLE OR EXTENSION CABLE. INSULATE AFTER TRIMMING. FOR -005, -008, AND -401 ANALYZERS, CONNECT THE CLEAR WIRE ONLY WHEN THE CABLE LENGTH EXCEEDS 50 FT. FIGURE 3-9. Solu Comp Wiring FIGURE Model 1054BC Wiring FIGURE Model 1055C Wiring FIGURE Model 54C & 54e C Wiring FIGURE Model Wiring 8
11 MODEL 403/403VP SECTION 3 WIRING DIAGRAMS AND CABLE PREPARATION FIGURE Model Wiring through Junction Box 9
12 MODEL 403/403VP SECTION 3 WIRING DIAGRAMS AND CABLE PREPARATION PREPARING UNTERMINATED CABLE FOR USE DWG. NO. REV A FIGURE Model 400 Series Cable Preparation (Part Number ) 10
13 MODEL 403/403VP SECTION 4 TROUBLESHOOTING SECTION 4. TROUBLESHOOTING INSPECTION Remove sensor from process and inspect electrodes for signs of wear or corrosion. Be sure vent holes are not blocked. CAUTION BEFORE REMOVING THE SENSOR, be absolutely certain the process pressure is reduced to 0 psig and the process temperature is at a safe level! TROUBLESHOOTING TABLE 4-1. Troubleshooting Guide Problem Probable Cause Action Off-scale readings Sensor is incorrectly wired to analyzer. Verify wiring. See Section 3. Temperature element in sensor is Check temperature element. See Figures 4-2 and 4-3. shorted or open. Replace the sensor if necessary. Sensor is not in process stream. Electrodes must be completely submerged in the process stream. See Section 2. Electrodes are fouled. Clean sensor. Sensor is defective. Perform isolation checks. See Figures 4-1 and 4-3. Replace the sensor if necessary. Variopol connector is not properly Loosen connector and reseat. seated. Noisy display Temperature element in sensor is Check temperature element. See Figures 4-2 and 4-3. shorted. Replace the sensor if necessary. Sensor is improperly installed in See Section 2. process stream. Variopol connector is not properly Loosen connector and reseat. seated. Sluggish response Electrodes are fouled. Inspect sensor and clean electrodes. Sensor is improperly installed in See Section 2. process stream. Low conductivity Air bubbles or sludge are trapped Be sure sensor is in a horizontal or nearly horizontal readings in sensor position. See Section 2. For additional troubleshooting advice, refer to analyzer instruction manual, or visit our website at to view deluxe manual. Cleaning Sensors Use a warm detergent solution and a soft brush or pipe cleaner to remove oil and scale. Do not use sandpaper, wire brushes, sand blasters, or drills. Avoid using acids to clean conductivity sensors. 11
14 MODEL 403/403VP SECTION 4 TROUBLESHOOTING FIGURE 4-1. Checking Continuity and Leakage Disconnect electrode leads and measure resistance and continuity as shown. Sensor must be dry when checking resistance between electrode leads. FIGURE 4-2. Checking Temperature Element Disconnect leads and measure resistances shown. The measured resistance at room temperature should be close to the value in the table. FIGURE 4-3. Model 400VP Pin Assignments - Top View 12
15 WARRANTY Goods and part(s) (excluding consumables) manufactured by Seller are warranted to be free from defects in workmanship and material under normal use and service for a period of twelve (12) months from the date of shipment by Seller. Consumables, ph electrodes, membranes, liquid junctions, electrolyte, O-rings, etc. are warranted to be free from defects in workmanship and material under normal use and service for a period of ninety (90) days from date of shipment by Seller. Goods, part(s) and consumables proven by Seller to be defective in workmanship and / or material shall be replaced or repaired, free of charge, F.O.B. Seller's factory provided that the goods, parts(s), or consumables are returned to Seller's designated factory, transportation charges prepaid, within the twelve (12) month period of warranty in the case of goods and part(s), and in the case of consumables, within the ninety (90) day period of warranty. This warranty shall be in effect for replacement or repaired goods, part(s) and consumables for the remaining portion of the period of the twelve (12) month warranty in the case of goods and part(s) and the remaining portion of the ninety (90) day warranty in the case of consumables. A defect in goods, part(s) and consumables of the commercial unit shall not operate to condemn such commercial unit when such goods, parts(s) or consumables are capable of being renewed, repaired or replaced. The Seller shall not be liable to the Buyer, or to any other person, for the loss or damage, directly or indirectly, arising from the use of the equipment or goods, from breach of any warranty or from any other cause. All other warranties, expressed or implied are hereby excluded. IN CONSIDERATION OF THE STATED PURCHASE PRICE OF THE GOODS, SELLER GRANTS ONLY THE ABOVE STATED EXPRESS WARRANTY. NO OTHER WARRANTIES ARE GRANTED INCLUDING, BUT NOT LIMITED TO, EXPRESS AND IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. RETURN OF MATERIAL Material returned for repair, whether in or out of warranty, should be shipped prepaid to: Rosemount Analytical Inc. Uniloc Division 2400 Barranca Parkway Irvine, CA The shipping container should be marked: Return for Repair Model The returned material should be accompanied by a letter of transmittal which should include the following information (make a copy of the "Return of Materials Request" found on the last page of the Manual and provide the following thereon): 1. Location type of service, and length of time of service of the device. 2. Description of the faulty operation of the device and the circumstances of the failure. 3. Name and telephone number of the person to contact if there are questions about the returned material. 4. Statement as to whether warranty or non-warranty service is requested. 5. Complete shipping instructions for return of the material. Adherence to these procedures will expedite handling of the returned material and will prevent unnecessary additional charges for inspection and testing to determine the problem with the device. If the material is returned for out-of-warranty repairs, a purchase order for repairs should be enclosed.
16 The right people, the right answers, right now. UNILOC DIVISION CUSTOMER SUPPORT CENTER ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE Credit Cards for U.S. Purchases Only. Rosemount Analytical Inc. Uniloc Division 2400 Barranca Parkway Irvine, CA USA Tel: (949) Rosemount Analytical Inc. 2000
245 Sanitary Flow-Through Toroidal Conductivity Sensor. Instruction Manual LIQ_MAN_245 Rev. D January 2014
245 Sanitary Flow-Through Toroidal Conductivity Sensor Instruction Manual LIQ_MAN_245 Rev. D January 2014 About This Document This manual contains instructions for installation and operation of the 245
More informationDissolved Oxygen Sensors
Instruction Sheet PN 51A-HxDO/rev.E July 2005 Models Hx438 and Gx448 Dissolved Oxygen Sensors For additional information, please refer to the Instruction Manuals CD shipped with this product, or visit
More informationRetractable ph/orp Sensor
Instruction Sheet PN 51A-398R/rev.H January 2011 Model 398R Retractable ph/orp Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. SPECIFICATIONS Measurements
More informationDual Input ph/conductivity Analyzer
Instruction Sheet PN 51A-1055pHC/rev.I January 2006 Model 1055 SOLU COMP II Dual Input ph/conductivity Analyzer Model Option 1055-22-30 For additional information, please refer to the Instruction Manuals
More informationDual Input ph/orp Analyzer
Instruction Sheet PN 51A-1055pH/rev.I February 2006 Model 1055 SOLU COMP II Dual Input ph/orp Analyzer Model Option 1055-22-32 For additional information, please refer to the Instruction Manuals CD shipped
More informationDual Input Toroidal Analyzer
Instruction Sheet PN 51A-1055T/rev.H February 2006 Model 1055 SOLU COMP II Dual Input Toroidal Analyzer Model Option 1055-21-31 For additional information, please refer to the Instruction Manuals CD shipped
More informationPURSense Sanitary Flange Conductivity Sensors
PURSense 403 & 403VP Sensors LIQ-PDS-PURSense-403-403VP-Sensors Product Data Sheet September 2015 PURSense Sanitary Flange Conductivity Sensors Conductivity sensor designed to meet USP requirements in
More informationRosemount 372. HF Resistant ph sensor. Quick Start Guide LIQ-QSG-372 Rev. C June 2017
Rosemount 372 HF Resistant ph sensor Quick Start Guide LIQ-QSG-372 Rev. C June 2017 hasgkas Essential Instructions Read this page before proceeding! Emerson designs, manufactures and tests its products
More informationQuick Start Guide LIQ-QSG-Hx338, Rev M July Rosemount Hx338. Steam Sterilizable and Autoclavable ph Sensor
Quick Start Guide LIQ-QSG-Hx338, Rev M July 2017 Rosemount Hx338 Steam Sterilizable and Autoclavable ph Sensor Safety Information WARNING! Do not exceed temperature and pressure limitations of 266 F (130
More informationHigh Pressure Conductivity Monitor
Product Data Sheet PDS 71-EDS880/1/rev.A August 2006 Model EDS880/1 High Pressure Conductivity Monitor COMPLETE SYSTEM FOR THE DETERMINATION OF CONDUCTIVITY IN HIGH PRESSURE SYSTEMS SENSOR INSTALLS DIRECTLY
More informationCavitator Ultrasonic Cleaners
Cavitator Ultrasonic Cleaners Instruction Manual 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com email:
More informationQuick Start Guide LIQ-QSG-Hx438, Rev A June Rosemount Hx438. Amperometric Steam Sterilizable Dissolved Oxygen Sensors
Quick Start Guide LIQ-QSG-Hx438, Rev A June 2017 Rosemount Hx438 Amperometric Steam Sterilizable Dissolved Oxygen Sensors Safety Information WARNING! Do not exceed temperature and pressure limitations
More informationRosemount 3200HP. ph Sensors. Instruction Manual LIQ-MAN-3200HP Rev. G April 2017
Rosemount 3200HP ph Sensors Instruction Manual LIQ-MAN-3200HP Rev. G April 2017 hasgkas Essential Instructions Read this page before proceeding! Emerson designs, manufactures and tests its products to
More informationCavitator Ultrasonic Cleaner Instruction Manual
Cavitator Ultrasonic Cleaner Instruction Manual Made in China 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com
More informationRosemount 3900/3900VP
Rosemount 3900/3900VP General Purpose ph/orp Sensor Instruction Manual LIQ-MAN-3900 Rev. G April 2017 hasgkas Essential Instructions Read this page before proceeding! Emerson designs, manufactures, and
More informationFree Chlorine Measuring System
Product Data Sheet PDS 71-FCL/rev.H September 2008 Model FCL Free Chlorine Measuring System COMPLETE SYSTEM INCLUDES sensor, connecting cable, analyzer, and flow controller. CONTINUOUS ph CORRECTION eliminates
More informationCavitator Ultrasonic Cleaner Instruction Manual Model 20G
Cavitator Ultrasonic Cleaner Instruction Manual Model 20G Made in China 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com
More informationDL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications
DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications 70-82-03-48 January 2003 Overview The DirectLine DL424/425 Sensor Modules are part of a family of products developed
More informationCavitator Ultrasonic Cleaners
Cavitator Ultrasonic Cleaners Instruction Manual (for model # 18G) 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com
More informationDL423 DirectLine Sensor Module for Conductivity Measurement Specifications
DL423 DirectLine Sensor Module for Conductivity Measurement Specifications 70-82-03-47 January 2003 Overview DirectLine DL423 for Conductivity measurement is a family of sensors released by Honeywell as
More informationCLARITY II TURBIDIMETER
Product Data Sheet PDS 71-T1055/rev.J January 2006 Model T1055 CLARITY II TURBIDIMETER COMPLETE SYSTEM includes single or dual input analyzer, sensor(s), and debubbler assembly CHOOSE U.S. EPA METHOD 180.1
More informationNext Generation Corona Discharge Auto Voltage Sensing Installation Manual
Next Generation Corona Discharge Auto Voltage Sensing Installation Manual 4-2122-01 Rev.B IMPORTANT SAFETY INSTRUCTIONS When installing and operating the Spa Eclipse ozone generator, basic precautions
More informationFigure 1 DirectLine DL423 Sensor. Description, continued
DL423 DirectLine Sensor Module for Conductivity Measurement Overview 70-82-03-47 4/02 Page 1 of 8 Specification DirectLine DL423 for Conductivity measurement is a family of sensors released by Honeywell
More informationToroidal (Electrodeless) Conductivity Sensors Series 5000TC Specifications
Toroidal (Electrodeless) Conductivity Sensors Series TC Specifications 7-82-3-37 June Overview The Honeywell TC toroidal (electrodeless) conductivity sensor measures the conductivity of solutions from.2
More informationRosemount 396/396VP/397/398/398VP
Instruction Manual Rev. M Rosemount 396/396VP/397/398/398VP ph/orp Sensors hasgkas Essential Instructions Read this page before proceeding! Emerson designs, manufactures and tests its products to meet
More information5000TC Series Toroidal (Electrodeless) Conductivity Sensors. Specification. Overview. Features. Description /00 Page 1 of 8
TC Series Toroidal (Electrodeless) Conductivity Sensors Overview The Honeywell TC toroidal (electrodeless) conductivity sensor measures the conductivity of solutions from.2 to millisiemens/cm. The sensors
More informationFigure 1 DirectLine DL423 Sensor. Description, continued
DL423 DirectLine Sensor Module for Conductivity Measurement Overview 70-82-03-47 1/03 Page 1 of 8 Specification DirectLine DL423 for Conductivity measurement is a family of sensors released by Honeywell
More informationTotal Chlorine Analyzer
Instruction Manual PN 51-TCL54e/rev.B May 2007 Model TCL Total Chlorine Analyzer ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount Analytical designs, manufactures, and tests its products
More informationTotal Chlorine Analyzer
Instruction Manual PN 51-TCL1055/rev.B May 2007 Model TCL Total Chlorine Analyzer ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount Analytical designs, manufactures, and tests its products
More informationCONTACTING CONDUCTIVITY BOILER SENSORS Instruction Manual
CONTACTING CONDUCTIVITY BOILER SENSORS Instruction Manual 5 Boyton Road Hopping Brook Park Holliston, MA 01746 TEL: 508-429-1110 Web: www.walchem.com Notice 2018 WALCHEM, Iwaki America Inc. (hereinafter
More informationIntrinsically Safe Transmitters, Option Code 2n
Installation Manual for Intrinsically Safe Transmitters, Option Code 2n ATEX PERSONAL INJURY WARNING DO NOT USE these products as safety or emergency stop devices or in any other application where failure
More informationSentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.
Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL www.aquaticsentry.com TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH AND LOW LEVEL ALARM 2.2 PUMP DOWN CONTROLLER 2.3
More informationFOAM MAKER MODEL - FMA & FMA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA INSTALLATION, TESTING AND MAINTENANCE APPLICATION SPECIFICATION
FOAM MAKER MODEL - FMA & FMA-S HD FIRE PROTECT TECHNICAL DATA MODEL INLET SIZE WORKING PRESSURE FMA-50, FMA-65 - Carbon Steel Construction FMA-S 50, FMA-S 65 - Stainless Steel Construction 50 NB, 65 NB
More informationInstruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007
CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications 3 rd Edition www.emersonprocess.com CAT 100 & CAT 200 Addendum for Hazardous Area Applications ESSENTIAL INSTRUCTIONS
More informationOzone + UV Sanitation
Ozone + UV Sanitation Installation Manual 4-2177-01 Rev.C IMPORTANT SAFETY INSTRUCTIONS When installing and operating the DEL Spa Solar Eclipse, basic precautions should always be followed: READ AND FOLLOW
More informationOWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions
634 10 Sunnen Drive St. Louis, MO 63143 telephone: 314-678-6336 fax: 314-781-2714 www.bloomfieldworldwide.com OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901 Includes: Installation
More informationInstruction Manual PN OZ/rev.K February Model SOLU COMP Ozone Analyzer
Instruction Manual PN 51-1055OZ/rev.K February 2006 Model SOLU COMP Ozone Analyzer II ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Your purchase from Rosemount Analytical, Inc. has resulted
More informationBentley II 13 in Ceiling Fan Owner s Manual. Bentley II Ventilador de Techo de 33 cm Manual del Propietario
Bentley II 13 in Ceiling Fan Owner s Manual Bentley II Ventilador de Techo de 33 cm Manual del Propietario 326 960 Bentley II by Hampton Bay 13 Bentley II Ceiling Fan by Hampton Bay Thank you for purchasing
More informationMCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA
MCD Corona Discharge Ozone Generators MANUFACTURED BY 3428 Bullock Lane San Luis Obispo, CA 93401 4-0622 Copyright 2005 DEL Ozone, Inc. IMPORTANT SAFETY INSTRUCTIONS When installing and using DEL Models
More informationAV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Rev A
AV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Flowline, Inc. 10500 Humbolt Street Los Alamitos, CA 90720 Tel: (562) 598-3015 Fax: (562) 431-8507 www.flowline.com 17
More informationMighty Venter Power Vent System
Installation and Operation Instructions Document 7008B Installation and Operation Instructions for Mighty Venter Power Vent System Models MV2, MV3, MV4, and MV5 for Mighty Therm Sizes 500-1825 FOR YOUR
More informationCONDENSING WATER BOILERS. (Models VLT , Q VX ,
Our Warranty By this warranty statement ( Limited Warranty ), ECR International, Inc. ( ECR ) issues limited warranties from the date of installation of the applicable Dunkirk Boiler ( Boiler ) to the
More informationMEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2
APT2000 Series 2-Wire Contacting Conductivity Transmitters Overview The Honeywell Analytical Process Transmitter (APT) 2000 Series transmitter is a two-wire 24-Volt device that continuously measures conductivity,
More informationMEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2
APT4000 Series 4-Wire Contacting Conductivity Analyzers Overview 70-82-03-45 10/03 Page 1 of 8 Specification The Honeywell Analytical Process Analyzer (APT) 4000 Series2 continuously measures conductivity,
More informationUser Manual. 110 Cup (55 Cup Raw) Gas Rice Cooker. Model: 177GRCLP, 177GRCNAT 12/2018. Please read and keep these instructions. Indoor use only.
110 Cup (55 Cup Raw) Gas Rice Cooker Intertek 5010781 Conforms to ANSI STD Z83.11-2016 Model: 177GRCLP, 177GRCNAT 12/2018 FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids
More informationSetra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions
Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions 1.0 GENERAL INFORMATION Every SRH humidity sensor product is tested and calibrated before
More informationIMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.
IMPORTANT SAFETY INSTRUCTIONS 2 1. Read and Follow All Instructions 2. Read this manual completely before attempting installation. 3. All permanent electrical connections should be made by a qualified
More informationFirst Year Limited Warranty for Residential Use Condensing Water Boilers (Includes Heat Exchanger and Component Parts)
THIS GIVES THE ORIGINAL PURCHASER ONLY SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER LEGAL RIGHTS WHICH VARY FROM STATE-TO-STATE AND -TO- Our Warranty By this warranty statement ( Limited Warranty
More informationInstruction Manual PN pH/rev.M February Model Solu Comp II. Dual Input ph Analyzer. Model Options and
Instruction Manual PN 51-1055pH/rev.M February 2006 Model Solu Comp II Dual Input ph Analyzer Model Options 1055-22-32 and 1055-22 ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Your purchase
More informationInstruction Manual PN 51-FCL/rev.H March Model FCL Free Chlorine Measuring System
Instruction Manual PN 51-FCL/rev.H March 2012 Model FCL Free Chlorine Measuring System ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Your purchase from Rosemount Analytical, Inc. has resulted
More informationInstallation and Operating Instructions
The Leader of RF and Sonic Level For Assistance Call 1-800-527-6297 Outside North America 1-215-674-1234 Installation and Operating Instructions Series 504-1200 Ultrasonic VeriGAP Switch using 404-1200
More informationREMOTE FAUCET PUMP SYSTEM
REMOTE FAUCET PUMP SYSTEM Use & Care Guide See Important Safeguards on Page 2 An exclamation point within an equilateral triangle is intended to alert user to the presence of important operating and maintenance
More informationOWNER S MANUAL & WARRANTY
OWNER S MANUAL & WARRANTY CONTAINS IMPORTANT PRODUCT INFORMATION FOR MODELS: Premier Lil Premier Lil Delux Kiddie Station Advantage Series Nature Series Silver Series IMPORTANT! Experiencing Any Set-Up
More informationA2Z Ozone, Inc. PRODUCT MANUAL
A2Z Ozone, Inc. PRODUCT MANUAL INSTALLATION & OPERATION MANUAL CE www.a2zozone.com Rev. 02142018 CONTENTS Page Important Safety Instructions... Specifications... Installation Instructions... 3 4 5 Troubleshooting...
More informationModel 4001 Series Single Channel Controller
Model 4001 Series Single Channel Controller Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 (800) 727-4377 (408) 262-9042 - Fax E-Mail: sales@sierramonitor.com Web site:
More informationNEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL
NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL 456 Creamery Way, Exton, PA 19341, USA Phone: 610.524.8800 Fax: 610.524.8807 Email: info@refrigerantid.com www.refrigerantid.com Page
More informationCONTROL BE MADE CHANGES MAY NOT. Page 1
HI 6020IT and HI 6020JB US & Canada Hazardous Locations User Guide (Class I, II, III, Division 1, Class I, Zone 0 and Zone 20) Hardy Process Solutions Document Number: : 0596-0352-01 REV A CONTROL LLED
More informationUnpacking Your Fan 2.
Excel Lighting & Manufacturing Ltd. Lifetime Limited Warranty Excel Lighting & Manufacturing Ltd. Warrants the fan motor to be free from defects in workmanship and material present at time of shipment
More informationRATIO:GUARD Model E-1S EC Monitor
EC probe Probe tees Probe retention clips Temperature probe E-1S monitor box UNPACKING Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing
More informationFOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION
FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT TECHNICAL DATA MODELS FCA-65, FCA-80 & FCA-100 FCA-150 Carbon Steel Construction INLET SIZE WORKING PRESSURE FCA-S 65, FCA-S 80 & FCA-S 100, FCA-S 150 Stainless
More informationTUBULAR LLdia-PUMPyy INSTRUCTIONS
TUBULAR LLdia-PUMPyy INSTRUCTIONS MODELS 515 to 547 MODELS 560,562,565 and 567 MATERIAL CODES N3, N5 and N7 ADDENDUM TO OPERATING AND INSTRUCTION MANUAL FOR 500 dia-pumps and FOR 560 dia-puws,these Instructions
More informationUSER MANUAL SOM SERIES MUL-T-POISE WARM AIR OIL FIRED FURNACE
USER MANUAL SOM SERIES MUL-T-POISE WARM AIR OIL FIRED FURNACE Save These Instructions For Reference ALL SOM SERIES FURNACES ARE AIR CONDITIONING READY! NOTICE TO HOMEOWNER THIS FURNACE SHALL BE INSTALLED
More informationLV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories
LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories Operating & Instruction Manual 1475 Lakeside Drive Waukegan, Illinois 60085 U.S.A. 847.473.4980
More informationInnovative Lighting R-Series Overhead LED Conversion Kits
Installation Guide Innovative Lighting R-Series Overhead LED Conversion Kits For Commercial Walk-In Coolers and Freezers BEFORE YOU BEGIN INSTALLATION Read these instructions carefully. Failure to follow
More informationOPERATING INSTRUCTIONS SMO112 WARM AIR OIL FIRED FURNACE
OPERATING INSTRUCTIONS SMO112 WARM AIR OIL FIRED FURNACE Save These Instructions For Reference SMO 112 FURNACES ARE AIR CONDITIONING READY! NOTICE TO HOMEOWNER THIS FURNACE SHALL BE INSTALLED BY A CERTIFIED
More informationLaminator with Hot & Cold settings
Laminator with Hot & Cold settings USER MANUAL LM990HC Please read these operating instructions before using the unit. Customer Service: 1-800-327-8508 WARNING / SAFETY INSTRUCTIONS Caution! Surface may
More informationBAY BRIDGE CEILING FAN
Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. ITEM #0451817 BAY BRIDGE CEILING FAN MODEL #CPJ1240 Español p. 19 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions,
More informationCamarillo 52 Ceiling Fan
Owner s Manual Camarillo 52 Ceiling Fan Part # 269263, 269259, 269287 Model # 32091, 32092, 32087 Exclusively Distributed by: HD Supply Facilities Maintenance, Ltd. Atlanta, GA 30339 2017 Made in China
More informationRoanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario
160 854 Roanoke 48 in Ceiling Fan Owner s Manual Roanoke Ventilador de Techo de 1,22 m Manual del Propietario 48 Roanoke Ceiling Fan by Hampton Bay Thank you for purchasing our ceiling fan. This product
More informationPre-Pack INTEGRATED PRE-ACTION SYSTEM
Pre-Pack INTEGRATED PRE-ACTION SYSTEM HD FIRE PROTECT TECHNICAL DATA MODEL Pre-Pack SIZE DELUGE VALVE MODEL RISER CHECK VALVE MODEL WATER MOTOR GONG BELL MAXIMUM WORKING PRESSURE SYSTEM END CONNECTION
More informationInstruction Manual PN 51-MCL/rev.C November Model MCL Monochloramine Measuring System
Instruction Manual PN 51-MCL/rev.C November 2004 Model MCL Monochloramine Measuring System ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Your purchase from Rosemount Analytical, Inc. has resulted
More informationDurafet Non-Glass ph Electrodes Specifications
Durafet Non-Glass ph Electrodes Specifications 70-82-03-50 February 2004 Description Honeywell defines state-of-the-art ph measurement with the Durafet ph electrode, an industrial, non-glass, unbreakable,
More informationModel 8730 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Outdoor Shower and Eyewash System General Area Classification & Class I Division 2
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com Website: www.hawsco.com Model 8730 Outdoor Shower and
More information(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)
Excel Lighting & Manufacturing Ltd. Lifetime Limited Warranty Excel Lighting & Manufacturing Ltd. Warrants the fan motor to be free from defects in workmanship and material present at time of shipment
More informationBROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF
BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS Product Submittal A PART OF Limited Warranty SprinkFLEX warrants that its products will be free from defects in materials and workmanship under normal conditions
More informationFlorentine IV 56 in Ceiling Fan Owner s Manual Florentine IV Ventilador de Techo de 1,42 m Manual del Propietario
Florentine IV 56 in Ceiling Fan Owner s Manual Florentine IV Ventilador de Techo de 1,42 m Manual del Propietario 527-541 Florentine IV by Hampton Bay 56 Florentine IV Ceiling Fan by Hampton Bay Thank
More informationDesiccant Tank Retrofit Kit for CD100/CS101 dehumidifying dryers
Desiccant Tank Retrofit Kit for CD100/CS101 dehumidifying dryers Installation Instructions Instant Access Parts and Service (800) 458-1960 (814) 437-6861 www.conairnet.com The Conair Group, Inc. One Conair
More informationOPERATIONS MANUAL DALPH1002, DALPH1503 PELLET HEATERS PALPH1002, PALPH1503 PLATE HEATERS. Alliance Products, LLC Murfreesboro, TN
Alliance Products, LLC Murfreesboro, TN 37129 1-800-522-3973 OPERATIONS MANUAL DALPH1002, DALPH1503 PELLET HEATERS PALPH1002, PALPH1503 PLATE HEATERS Rev. 1-28 2 GENERAL INFORMATION. 3 RECEIVING INSPECTIONS.
More informationRemote Relay Module (RRM)
Remote Relay Module (RRM) Instruction Manual WARNING THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR INSTALLING, USING OR SERVICING THIS PRODUCT. Like
More informationMagnetically Operated Touch Panel Hints on Operating CAT 100 / BINOS 100 F and CAT 200 / MLT 2 Gas Analyzers
Instruction Manual Magnetically Operated Touch Panel Hints on Operating CAT 100 / BINOS 100 F and CAT 200 / MLT 2 Gas Analyzers www.processanalytic.com ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING!
More informationDRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual
DRRRRDRY-PAK Instruction and Installation Manual IB-160 Rev. B P/N 36595 Registered by UL to ISO 9001 DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual INSTALLATION: Models DS0-00-000 through
More informationGG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual
GG-CO-EXP CARBON MONOXIDE SENSOR Installation and Operation Manual 2 GG-CO-EXP Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by
More informationCD6102 / CD6102 OC / CD6102-2
PreView Display CD6102 / CD6102 OC / CD6102-2 Operating Manual www.previewradar.com PATENTS Patented under one or more of the following U.S. Patents: 5345471, 5523760, 5457394, 5465094, 5512834, 5521600,
More informationNT DUAL CHANNEL DISPLAY. User Guide
NT DUAL CHANNEL DISPLAY User Guide Table of Contents Introduction... 2 Input Signals... 2 Output Signals... 2 User Programmable Features... 2 Installation... 3 Mechanical Installation... 3 Dimensional
More informationPodView Level Indicator LI40 Series Manual
PodView Level Indicator LI40 Series Manual Flowline Inc. 10500 Humbolt Street Los Alamitos, CA 90720 Tel: (562) 598 3015 Fax: (562) 431 8507 www.flowline.com Rev A MN204260 1 of 16 INTRODUCTION / TABLE
More informationInstallation & Operation Manual Ice Cream Freezers
Installation & Operation Manual Ice Cream Freezers Please read this manual completely before installing or operating this unit! BACF11 BACF15 Blue Air reserves the right to make product modification at
More informationModel /8320CRP Shower and Eye/Face Wash
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 8320-8325/8320CRP Shower
More informationMN908 No. 282C Replaces 282B LB7013
No. 282C Replaces 282B LB7013 Instruction Manual For Baldor Dust Control Units Models DC7, DC7 3, DC8, DC8 3, DC10, DC10 3, DC12, DC12 3 and DC14 3. For use on Grinders mounted to GA16 and GA20 pedestals
More informationQuest Power Electric Heat EHS 31 Pro
Quest DRY Power 150 Electric Heat EHS 31 Pro Read and Save These Instructions The Power Electric Heat EHS 31 Pro portable, heavy duty electric heater features a built-in 50-amp twist lock receptacle designed
More information55-Gallon Dispenser Package
INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 308 666 Rev. A Husky 715 55-Gallon Dispenser Package 100 psi (6.9 bar) Maximum
More informationInstallation and Operation Manual. ACF-18 Automatic Chlorinating Feeder
Installation and Operation Manual ACF-18 Automatic Chlorinating Feeder Operating Specifications Inlet Flow: 1.0-1.5 gpm Outlet Flow: = Inlet Flow Inlet Pressure: 10-45 psi Maximum Output: 26 lbs. of Available
More informationBX600. CLASSIC ColleCtion. Specifications. Model Colour Venting Size. Air Flow Volume: Electrical Consumption:
BX600 Innovation by Design - Since 1991 CLASSIC ColleCtion Insert Cyclone s newest insert is discreet and quiet yet bold and powerful enough to leave a distinct impression. Powered at 600 CFM and fitted
More informationBlue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers
Blue Air Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers Please read this manual completely before installing or operating this unit! BACF11 BACF15 BACRF14 Blue Air reserves
More informationManual LIQ-MAN-TCL-1056, Rev E July Rosemount TCL. Total Chlorine System with Rosemount 1056 Transmitter
Manual LIQ-MAN-TCL-1056, Rev E July 2017 Rosemount TCL Total Chlorine System with Rosemount 1056 Transmitter Essential instructions Read this page before proceeding! Rosemount designs, manufactures, and
More informationModel 8300FP Freeze Resistant Combination Shower Eye/Face Wash
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 8941-6467 (775) 59-4712 Fax (775) 59-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 800FP Freeze Resistant Combination
More informationUSER MANUAL SLO / SFLO115 SERIES OIL FIRED WARM AIR FURNACES
USER MANUAL SLO / SFLO115 SERIES OIL FIRED WARM AIR FURNACES Save These Instructions For Reference ALL SUMMERAIRE SLO115 / SFLO115 MODELS ARE AIR CONDITIONING READY! NOTICE TO HOMEOWNER THIS FURNACE SHALL
More informationInnovative Lighting R-Series Vertical Refrigeration
Installation Guide Innovative Lighting R-Series Vertical Refrigeration Door LED Conversionn Kits For Commercial Refrigerators and Freezers BEFORE YOU BEGIN INSTALLATION Read these instructions carefully.
More informationDurafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications
Durafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications 70-82-03-06 July 2004 Overview Honeywell s 7777 Series of electrode mountings enables an
More informationAC 4 & 5 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY ELECTRICAL CONNECTIONS INSTALLATION
AC 4 & 5 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY PUMPS WITH MOTORS 1. No assembly required. Unpack the pump and motor and examine for any
More informationTL-105 COLUMN HEATER
TL-105 COLUMN HEATER INSTRUCTION MANUAL Timberline Instruments Inc. 1880 S. Flatiron Ct., Unit I Boulder, Colorado 80301 Ph: (303) 440-8779 Fx: (303) 440-8786 info@timberlineinstruments.com www.timberlineinstruments.com
More information