245 Sanitary Flow-Through Toroidal Conductivity Sensor. Instruction Manual LIQ_MAN_245 Rev. D January 2014

Size: px
Start display at page:

Download "245 Sanitary Flow-Through Toroidal Conductivity Sensor. Instruction Manual LIQ_MAN_245 Rev. D January 2014"

Transcription

1 245 Sanitary Flow-Through Toroidal Conductivity Sensor Instruction Manual LIQ_MAN_245 Rev. D January 2014

2 About This Document This manual contains instructions for installation and operation of the 245 Sanitary Flow-Through Toroidal Conductivity Sensor. The following list provides notes concerning all revisions of this document. Rev. Level Date Notes A 2/04 This is the initial release of the product manual. The manual has been reformatted to reflect the Emerson documentation style and updated to reflect any changes in the product offering. B 1/08 Addition of section 1.7 on page 5 C 3/12 Update pages 12 and 16 D 01/14 The manual has been reformatted to reflect the Emerson documentation style and updated to reflect any changes in the product offering. Wiring diagrams were also added under Section 1.

3 Essential Instructions Read this page before proceeding Rosemount Analytical designs, manufactures, and tests its products to meet many national and international standards. Because these instruments are sophisticated technical products, you must properly install, use, and maintain them to ensure they continue to operate within their normal specifications. The following instructions must be adhered to and integrated into your safety program when installing, using, and maintaining Rosemount Analytical products. Failure to follow the proper/ instructions may cause any one of the following situations to occur: Loss of life; personal injury; property damage; damage to this instrument; and warranty invalidation. Read all instructions prior to installing, operating, and servicing the product. If this Instruction Manual is not the correct manual, telephone and the requested manual will be provided. Save this Instruction Manual for future reference. If you do not understand any of the instructions, contact your Rosemount representative for clarification. Follow all warnings, cautions, and instructions marked on and supplied with the product. Inform and educate your personnel in the proper installation, operation, and maintenance of the product. Install your equipment as specified in the Installation Instructions of the appropriate Instruction Manual and per applicable local and national codes, for example, ANSI B16.5. Connect all products to the proper electrical and pressure sources. To ensure proper performance, qualified personnel should install, operate, and maintain the product. When replacement parts are required, ensure that qualified people use replacement parts specified by Rosemount Analytical. Replacement of original components with those constructed from alternative materials will void any CSA, FM, and BASEEFA/CENELEC agency approvals that were applicable to the original device. Furthermore, replacement of original components with those constructed from alternative materials might change the pressure, temperature, and/or performance specifications from those of the original configuration. Ensure replacement parts are compatible with process requirements. Unauthorized parts and procedures can affect the product s performance, place the safe operation of your process at risk, and may result in fire, electrical hazards, or improper operation. Ensure that all equipment doors are closed and protective covers are in place, except when maintenance is being performed by qualified persons, to prevent electrical shock and personal injury. DANGER HAZARDOUS AREA INSTALLATION Installations near flammable liquids or in hazardous area locations must be carefully evaluated by qualified on site safety personnel. This sensor is not Intrinsically Safe or Explosion Proof. To secure and maintain an intrinsically safe installation, the certified safety barrier, transmitter, and sensor combi nation must be used. The installation system must comply with the governing approval agency (FM, CSA, BASEEFA/CENELEC, or ATEX) hazardous area classification requirements. Consult your analyzer/ transmitter instruction manual for details. Replacement of original components with those constructed from alternative materials will void any CSA, FM, and BASEEFA/CENELEC agency approvals that were applicable to the original device. Proper installation, operation and servicing of this sensor in a Hazardous Area Instal lation is entirely the responsibility of the user. CAUTION: SENSOR/PROCESS APPLICATION COMPATIBILITY The wetted sensor materials may not be compatible with process com position and operating conditions. Replacement of original components with those constructed from alternative materials might change the pressure, temperature, and/or performance specifications from those of the original sensor configuration. Application compat ibility is entirely the responsibility of the user.

4

5 Instruction Manual Table of Contents LIQ_MAN_245 January 2014 Contents Section 1: 245 Sensor Features and Applications Specifications Ordering Information Installation Calibration Calibration Verification Wiring Maintenance... 7 List of Tables Section 2: Troubleshooting...9 Section 3: Return of Materials General Warranty Repair Non-Warranty Repair Nominal Cell Constants for 245 Sensors Resistance Values for RTD Sensor Wire Resistance Values with Instrument Cable Disconnect... 9 List of Figures Figure Sanitary Flow-Through Toroidal Conductivity Sensor... 2 Figure Junction Box with RTD Diagram...4 Figure Sensor to Junction Box Wiring... 5 Figure Extension Cable... 6 Figure Figure Wiring Extension Cable to 54ec... 6 Figure Figure Wiring Extension cable to 1056 and Figure Figure Wiring Extension cable to Xmt-T (Panel Mount)... 6 Figure Figure Wiring Extension Cable to Xmt-T (Pipe/Wall Mount)... 7 Figure Figure Wiring Extension Cable to 1066-T... 7 Figure Figure Wiring Extension Cable to 5081T... 7 Figure Figure Sensor Circuit for Troubleshooting Table of Contents i

6 Table of Contents January 2014 Instruction Manual LIQ_MAN_245 This page left blank intentionally

7 Instruction Manual 245 Sensor LIQ_MAN_245 January 2014 Section 1: 245 Sensor 1.1 Features and Applications The 245 Sanitary Flow-Through Toroidal Conductivity Sensor is intended for use in the pharmaceutical, biopharmaceutical, and food and beverage industries where a conductivity sensor that does not obstruct the process flow is required. The sensor consists of two toroids surrounding a PEEK liner through which the liquid flows. An alternating voltage applied to the first toroid induces a voltage in the liquid, which causes an ionic current to flow. The ionic current is directly proportional to the conductance of the liquid. The ionic current, in turn, induces a proportional current in the second toroid. The analyzer measures this current and displays the conductivity of the liquid. For a current to flow in the second toroid, a complete electric circuit must exist around the toroids. The sample passing through the toroid openings forms part of the circuit. The metal mounting flanges at the end of the sensor, which contact the liquid and are connected by the metal housing passing outside the toroids, complete the circuit. The 245 sensor is available with 0.5, 1.0, 1.5, and 2 inch Tri Clamp connections. The liner meets the requirements of 21CFR , and the O-rings meet 21CFR Both the liner and the O-rings are compliant with USP Class VI requirements. The 245 sensor is easy to install. It clamps into the process piping between two Tri Clamp flanges. Installation of special grounding rings is not needed because contact rings are already built into the sensor. A junction box to facilitate wiring is included. Conductivity depends strongly on temperature, and conductivity measurements are typically corrected to a reference value. A Pt 100 or Pt 1000 RTD, provided by the user, can be wired into the sensor junction box, allowing the analyzer to measure temperature and use it for automatic temperature correction. The 245 is not sensitive to flow rate or direction. It does not obstruct the process flow. The 245 Sanitary Flow-Through Conductivity Sensor is compatible with the 1056, 56, 5081T, and 1066-T. 1.2 Specifications Installation Type: Conductivity Range: Process Connections: Wetted Materials: Surface Finish: Minimum Temperature: Maximum Temperature: Maximum Pressure Maximum Pressure (all others): Shipping Weight: Flow through Consult analyzer product data sheet ½ inch, 1 inch, 1 ½ inch, and 2 inch 316L stainless steel (mounting flanges); unfilled PEEK (liner); EPDM (O-rings). PEEK liner meets 21CFR and USP Class VI. EPDM O-rings meet 21CFR and USP Class VI, Mounting flanges have a 16 micro inch (0.41 um) Ra surface finish. PEEK liner has a 32 micro inch (0.81 um) Ra surface finish. 32 F (0 C) 250 F (121 C) continuous; 266 F (130 C) in steam for 45 minutes (½ inch sensor only): 300 psig (2170 kpa abs) 100 psig (791 kpa abs) 9 lb (4.5 kg) 245 Sensor 1

8 245 Sensor Instruction Manual January 2014 LIQ_MAN_245 Figure 1-1 Sanitary Flow-Through Toroidal Conductivity Sensor 1.3 Ordering Information The 245 Sanitary Flow-Through Sensor is configurable to meet the needs of many applications and installations. A NEMA 7D junction box is also included. Compatible instruments include Rosemount Analytical 1056, 56, 5081T, and 1066-T. The extension cable required for wiring from the junction box to the instrument is ordered separately. The customer supplies the mating flanges, clamps, gaskets, and Pt 1000 RTD. Model 245 CODE 01 ½ ½ 04 2 CODE 12 Tri Clamp Sanitary Flow-Through Toroidal Conductivity Sensor LINE SIZE (Required Selection) PROCESS CONNECTION (Required Selection) CODE SS CODE PK CONTACT RING MATERIAL (Required Selection) 316L Stainless Steel LINER MATERIAL (Required Selection) unfilled PEEK CODE PROCESS O-RING MATERIAL (Required Selection) EP EP O-rings SS -PK -EP EXAMPLE Accessories Part # Description Extension cable, prepped, for connection to instruments 1056, 56, 5081, 1066-T (Specify length) RTD Mounting Accessory Kit, consisting of ¾ NPT tee, nipple, and cable connectors Sensor

9 Instruction Manual 245 Sensor LIQ_MAN_245 January Installation Before starting installation, determine whether the analyzer/transmitter will be calibrated at the bench or on-line. If bench calibration is to be performed, wiring instructions can be found at the end of this section and calibration procedures can be found in Section 1.5. Installation of the 245 Flow Through Sensor is similar to installation of a section of pipe. Consequently, be prepared to use tools, supplies, equipment, and techniques similar to those used to install process pipes. Use common piping practices to minimize torque and bending loads on process connections. Observe all applicable safety standards. Dimensional information is shown in Figure 1-2 below. Note 1. The sensor should be installed into a straight section of piping at least 4 pipe diameters in length on either side of the sensor to optimize sensor performance. 2. The sensor should be installed at an orientation that will keep the sensor filled with process solution at all times during which measurements are being made. Avoid downward flowing solutions as such a configuration might leave the sensor partially empty. Installing the Sensor in the Process Line 1. Install Tri-Clamp flanges onto pipes in accordance with applicable instructions, standards, and local regulations. 2. Position the sensor between the Tri-Clamp flanges with the flange gaskets inserted between each set of flanges. Ensure that the locations of the junction box connection and the RTD are suitable for ease of the remainder of installation, wiring, and use. Installing the Pt100 RTD 1. Use of the optional Pt100 RTD is recommended. Use of a customer-supplied Pt100 or Pt1000 TC mounted in a separate thermowell is also acceptable. 2. Thread the RTD wires into junction box. Wire the RTD to the j-box terminals as indicated in Figure 1-4. Use of optional kit PN is recommended. Extension Cable Hook-Up 1. Sensor cable should not be run in conduit or open trays with any A.C. power wiring, nor routed near heavy electrical equipment. 2. For best sensor/instrument loop performance, using the preprepared extension cable (PN ) is recommended. (Using a different cable can introduce noise into the signal and/or reduce loop accuracy.) 3. One end of extension cable (PN ) has 8 wires, and the other end has 11 wires. Refer to Figure 1-4. The end with only 8 wires goes into the junction box. The end with 11 wires goes to the instrument. Note If starting with unprepped cable (PN ), remove only as much insulation as is necessary. The instrument end needs 11 leads: four leads from the green-white-blackdrain bundle, three from each of the two coaxial cable bundles (the inner conductor, the insulating braid, and the drain wire), and one from the outermost overall braided-copper shield. For the junction-box end, only 8 leads are used: the white coaxial conductor, its braided shield, the green coaxial conductor, its braided shield, its drain wire, and the green, white, and black conductors from the green-white-black-drain bundle. The remaining shields and drain wires are not used on the J-box end and should be removed -- they should NOT be connected or allowed to short to any other conductor or the junction box. 4. Connect the 8 wires of the extension cable to the terminal block inside the sensor s junction box as indicated in Figure 1-3 and Figure Connect the 11 wires of the instrument-end of the extension cable according to the applicable diagram from Figures 1-5 through 1-9, the Wiring Instruction Sheet, or the instrument s instructions. 245 Sensor 3

10 245 Sensor Instruction Manual January 2014 LIQ_MAN_245 Figure Junction Box with RTD Diagram (use of optional kit PN is recommended) 1.5 Calibration Before starting the calibration, enter the nominal cell constant into the analyzer. See Table 1-1. The accuracy of the nominal cell constant is probably no better than 10%. For greater accuracy, calibrate the sensor. Table 1-1 Nominal Cell Constants for 245 Sensors Sensor Size Nominal Cell Constant ½ Calibration against a standard solution 1. Obtain a suitable conductivity standard. If the sensor is being used to measure a broad range of conductivity, choose a standard in the midpoint of the operating range. Otherwise, choose a standard near the expected process conductivity. 2. Attach a blank flange to one end of the sensor. Stand the sensor on the sealed end. 3. Decide whether temperature correction is needed. a. If the conductivity of the standard as a function of temperature is known, configure the analyzer to measure raw conductivity (no temperature correction). Also, obtain a calibrated thermometer. Place the thermometer in a beaker of water next to the sensor. DO NOT PUT THE THERMOMETER IN THE SENSOR. b. If the conductivity of the standard is known only at 25 ºC, leave the analyzer slope temperature correction on and set the temperature coefficient to the appropriate value. If the temperature coefficient is not given, consult the manufacturer of the standard. Also, obtain a calibrated Pt 100 RTD and connect it to the analyzer. See Wiring Diagrams. Place the RTD in a beaker of water next to the sensor. DO NOT PUT THE RTD IN THE SENSOR 4. Fill the sensor with standard. Be sure no air bubbles are sticking to the liner and the sensor is completely filled. 5. Wait for the standard and the water in the beaker containing the thermometer or RTD to come to thermal equilibrium. 6. Refer to the analyzer instruction manual and adjust the analyzer display to match the conductivity of the standard at either the temperature of the standard (step 3a) or at 25 ºC (step 3b) Sensor

11 Instruction Manual 245 Sensor LIQ_MAN_245 January In-line calibration against a laboratory measurement 1. Install the sensor in the process piping. 2. Obtain and calibrate a laboratory conductivity meter and sensor capable of measuring the conductivity of the process liquid. 3. Collect a sample of the process liquid and measure the conductivity using the laboratory instrument. The temperature of the sample is likely to change during handling. For this reason, use temperature compensation in both the process and laboratory analyzer. Be sure the temperature correction algorithms are identical. 4. Refer to the analyzer instruction manual and adjust the analyzer display to match the conductivity measured in the laboratory. 1.6 Calibration Verification Calibration verification is a way of monitoring changes that might occur in the external toroids during service. It does not detect changes in the contact rings. It is not a calibration. 1. Empty and dry the sensor. 2. Attach a resistance decade box to the two yellow wires. See Figure Configure the analyzer to measure raw conductivity (no temperature compensation). 4. Adjust the resistance until the analyzer display reads the same number it did during calibration. Record the resistance value, the displayed value, and the temperature. Calibration verification can be used to check the toroids while the sensor is in the process line. 1. Drain the process line. 2. Connect a resistance decade box to the yellow wires. 3. Configure the analyzer to measure raw conductivity. 4. Set the decade box to the value noted in step 4 above. The analyzer reading should match the original reading to within ±20%. 1.7 Wiring NOTE For additional wiring information on this product, including sensor combinations not shown here, please refer to either our online wiring programs or the Manual DVD enclosed with each product. 1056, 1057, 56, 5081, 6081, 54e, and XMT : sp/liquid/wiring/xmt/ 1066 and sensors with SMART preamps: brands/rosemountanalytical/liquid/sensors/pages/wiring_diagram.aspx 1055: Figure1-3 Sensor to Junction Box Wiring 245 Sensor 5

12 245 Sensor Instruction Manual January 2014 LIQ_MAN_245 Figure 1-4 Extension Cable Figure1-5 Wiring extension cable to 54ec Figure1-6 Wiring extension cable for 1056 and 56 Figure1-7 Wiring extension cable to Xmt-T (Panel Mount) Sensor

13 Instruction Manual 245 Sensor LIQ_MAN_245 January 2014 Figure1-8 Wiring extension cable to Xmt-T (Pipe/Wall Mount) Figure1-9 Wiring extension cable to 1066-T Figure 1-10 Wiring extension Cable to 5081T TB2 TB1 RTN SENSE RTD IN SHLD CLEAR GREEN WHITE BLACK BLACK GREEN CLEAR BLACK WHITE CLEAR RCV B RCV A RSHLD DRV B DRV A DSHLD CLEAR CLEAR SHIELD CONNECTED. IT IN HIGH TEMPE (OPTION-03) ON Maintenance The only routine maintenance required during the operational life of the sensor is to ensure that there are no deposits plugging the sensor or coating the inside of the contact rings. Some customers find it advantageous to periodically replace process (Tri-Clamp) gaskets to ensure adequate process seals. Rebuilding the sensor must be done at the factory. 245 Sensor 7

14 245 Sensor Instruction Manual January 2014 LIQ_MAN_245 This page left blank intentionally Sensor

15 Instruction Manual Troubleshooting LIQ_MAN_245 January 2014 Section 2: Troubleshooting 2.1 Troubleshooting To check the toroids, recall the data obtained during the Calibration Verification Process (see Section 1.6). With the sensor empty of process fluids (preferably also clean and dry), reapply the resistance to the yellow Cal Loop wires in the junction box. The reading should be within + 20% of its original value. To check the RTD, disconnect RTD leads of the interconnecting cable (PN ) and measure the resistance across the white and one of the red RTD wire terminals in the junction box. See Figure 1-4. The resistance value should be close to the applicable value shown in Table 2-1. Finally, check the sensor for open connections and short circuits. Be sure to disconnect the cable (PN ) before checking. See Table 2-2 and Figure 2-1. Table 2-1 Resistance Values for Pt 100 and Pt 1000 RTDs Temperature Resistance (Ohms) ( C/ F) Pt 100 Pt / / / / / / / / / / Table 2-2. Sensor Wire Resistance Values with Instrument Cable Disconnected (instrument leads and gray wire connected to terminal block, see Figure 2-1) Connection (wire or component connections) Each twisted pair, WHITE to GRAY YELLOW to YELLOW WHITE to WHITE RED to YELLOW RED to each WHITE YELLOW to each WHITE ALL except RED to housing EARTH screw RED to housing EARTH screw Resistance 0.4 to 0.9 Ω 0.1 to 0.5 Ω > 20 MΩ > 20 MΩ > 20 MΩ > 20 MΩ > 20 MΩ 0.1 to 0.5 Ω Troubleshooting 9

16 Section Title January 2014 Instruction Manual LIQ_MAN_245 Figure 2-1 Sensor Circuit for Troubleshooting 10 Troubleshooting

17 Instruction Manual Return of Materials LIQ_MAN_245 January 2014 Section 3: Return of Materials 3.1 General To expedite the repair and return of instruments, proper communication between the customer and the factory is important. A return material authorization number is required. Call (949) The Return of Materials Request form is provided for you to copy and use in case the situation arises. The accuracy and completeness of this form will affect the processing time of your materials. 3.2 Warranty Repair The following is the procedure for returning products still under warranty. 1. Contact the factory for authorization. 2. Complete a copy of the Return of Materials Request form as completely and accurately as possible. 3. To verify warranty, supply the factory sales order number or the original purchase order number. In the case of individual parts or sub-assemblies, the serial number on the mother unit must be supplied. 4. Carefully package the materials and enclose your Letter of Transmittal and the completed copy of the Return of Materials Request form. If possible, pack the materials in the same manner as it was received. Important Please see second section of Return of Materials Request Form. Compliance to the OSHA requirements is mandatory for the safety of all personnel. MSDS forms and a certification that the instruments have been disinfected or detoxified are required. 5. Send the package prepaid to: Rosemount Analytical Inc Barranca Parkway Irvine, CA Attn: Factory Repair Mark the package: Returned for Repair RMA No. Model No. 3.3 Non-Warranty Repair 1. Contact the factory for authorization. 2. Fill out a copy of the Return of Materials Request form as completely and accurately as possible. 3. Include a purchase order number and make sure to include the name and telephone number of the right individual to be contacted should additional information be needed. 4. Do Steps 4 and 5 of Section 4.2. NOTE Consult the factory for additional information regarding service or repair. Return of Materials 11

18

19 WARRANTY Seller warrants that the firmware will execute the programming instructions provided by Seller, and that the Goods manufactured or Services provided by Seller will be free from defects in materials or workmanship under normal use and care until the expiration of the applicable warranty period. Goods are warranted for twelve (12) months from the date of initial installation or eighteen (18) months from the date of shipment by Seller, whichever period expires first. Consumables, such as glass electrodes, membranes, liquid junctions, electrolyte, o-rings, catalytic beads, etc., and Services are warranted for a period of 90 days from the date of shipment or provision. Products purchased by Seller from a third party for resale to Buyer ( Resale Products ) shall carry only the warranty extended by the original manufacturer. Buyer agrees that Seller has no liability for Resale Products beyond making a reasonable commercial effort to arrange for procurement and shipping of the Resale Products. If Buyer discovers any warranty defects and notifies Seller thereof in writing during the applicable warranty period, Seller shall, at its option, promptly correct any errors that are found by Seller in the firmware or Services, or repair or replace F.O.B. point of manufacture that portion of the Goods or firmware found by Seller to be defective, or refund the purchase price of the defective portion of the Goods/Services. All replacements or repairs necessitated by inadequate maintenance, normal wear and usage, unsuitable power sources, unsuitable environmental conditions, accident, misuse, improper installation, modification, repair, storage or handling, or any other cause not the fault of Seller are not covered by this limited warranty, and shall be at Buyer s expense. Seller shall not be obligated to pay any costs or charges incurred by Buyer or any other party except as may be agreed upon in writing in advance by an authorized Seller representative. All costs of dismantling, reinstallation and freight and the time and expenses of Seller s personnel for site travel and diagnosis under this warranty clause shall be borne by Buyer unless accepted in writing by Seller. Goods repaired and parts replaced during the warranty period shall be in warranty for the remainder of the original warranty period or ninety (90) days, whichever is longer. This limited warranty is the only warranty made by Seller and can be amended only in a writing signed by an authorized representative of Seller. Except as otherwise expressly provided in the Agreement, THERE ARE NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EXPRESS OR IMPLIED, AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, OR ANY OTHER MATTER WITH RESPECT TO ANY OF THE GOODS OR SERVICES. RETURN OF MATERIAL Material returned for repair, whether in or out of warranty, should be shipped prepaid to: Emerson Process Management Rosemount Analytical 2400 Barranca Parkway Irvine, CA The shipping container should be marked: Return for Repair Model The returned material should be accompanied by a letter of transmittal which should include the following information (make a copy of the Return of Materials Request found on the last page of the Manual and provide the following thereon): 1. Location type of service, and length of time of service of the device. 2. Description of the faulty operation of the device and the circumstances of the failure. 3. Name and telephone number of the person to contact if there are questions about the returned material. 4. Statement as to whether warranty or non-warranty service is requested. 5. Complete shipping instructions for return of the material. Adherence to these procedures will expedite handling of the returned material and will prevent unnecessary additional charges for inspection and testing to determine the problem with the device. If the material is returned for out-of-warranty repairs, a purchase order for repairs should be enclosed.

20 LIQ_MAN_ABR_245 January 2014 Rev. D The right people, the right answers, right now. Immediate, Reliable Analytical Support Now there s a way to quickly get the right answers for your liquid analytical instrumentation questions: the Analytical Customer Support Center. Our staff of trained professionals is ready to provide the information you need. If you are placing an order, verifying delivery, requesting application information, or just want to contact an Emerson Process Management representative, a call to the Customer Support Center will provide you with the right people, the right answers, right now. A Worldwide Network of Sales and Service Emerson Process Management s field sales offices are your source for more information on the fill line of Rosemount Analytical products. Field sales personnel will work closely with you to supply technical data and application information. For more information, please contact your nearest Emerson Process Management sales office. THE AMERICAS - HEADQUARTERS Emerson Process Management 2400 Barranca Parkway Irvine, CA USA Tel: (949) Fax: (949) rosemountanalytical.com ASIA-PACIFIC Emerson Process Management Asia Pacific Private Ltd. 1 Pandan Crescent Singapore 0512 Republic of Singapore Tel: Fax: LATIN AMERICA Emerson Process Management Rosemount Analytical West Little York, Suite #200 Houston, TX USA T F MIDDLE EAST AND AFRICA Emerson Process Management EPM Building P. O. Box Jebe Ali Free Zone Dubai, United Arab Emirates T F facebook.com/emersonrosemountanalytical AnalyticExpert.com twitter.com/raihome youtube.com/user/rosemountanalytical EUROPE Emerson Process Management Heath Place Bognor Regis West Sussex PO22 9SH England Tel: Fax: GERMANY Emerson Process Management Process Gas Analyzer Center of Excellence GmbH & Co. OHG Industriestrasse Hasselroth Germany T F Rosemount Analytical, Inc. All rights reserved. Credit Cards for U.S. Purchases Only. The Emerson logo is a trademark and service mark of Emerson Electric Co. Brand name is a mark of one of the Emerson Process Management family of companies. All other marks are the property of their respective owners. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.

ENDURANCE Conductivity Sensors

ENDURANCE Conductivity Sensors Models 403 and 403VP Instruction Manual PN 5100403 February 2001 ENDURANCE Conductivity Sensors Model 403 Model 403VP Sanitary Flange Sensors Sanitary Flange Sensors with Variopol Connector ESSENTIAL INSTRUCTIONS

More information

Duct Mount. Installation Instructions

Duct Mount. Installation Instructions Duct Mount Installation Instructions 00809-0600-4975 Legal Notice The Flame Detector described in this document is the property of Rosemount. No part of the hardware, software, or documentation may be

More information

PURSense Sanitary Flange Conductivity Sensors

PURSense Sanitary Flange Conductivity Sensors PURSense 403 & 403VP Sensors LIQ-PDS-PURSense-403-403VP-Sensors Product Data Sheet September 2015 PURSense Sanitary Flange Conductivity Sensors Conductivity sensor designed to meet USP requirements in

More information

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007 CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications 3 rd Edition www.emersonprocess.com CAT 100 & CAT 200 Addendum for Hazardous Area Applications ESSENTIAL INSTRUCTIONS

More information

Retractable ph/orp Sensor

Retractable ph/orp Sensor Instruction Sheet PN 51A-398R/rev.H January 2011 Model 398R Retractable ph/orp Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. SPECIFICATIONS Measurements

More information

Magnetically Operated Touch Panel Hints on Operating CAT 100 / BINOS 100 F and CAT 200 / MLT 2 Gas Analyzers

Magnetically Operated Touch Panel Hints on Operating CAT 100 / BINOS 100 F and CAT 200 / MLT 2 Gas Analyzers Instruction Manual Magnetically Operated Touch Panel Hints on Operating CAT 100 / BINOS 100 F and CAT 200 / MLT 2 Gas Analyzers www.processanalytic.com ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING!

More information

Rosemount 372. HF Resistant ph sensor. Quick Start Guide LIQ-QSG-372 Rev. C June 2017

Rosemount 372. HF Resistant ph sensor. Quick Start Guide LIQ-QSG-372 Rev. C June 2017 Rosemount 372 HF Resistant ph sensor Quick Start Guide LIQ-QSG-372 Rev. C June 2017 hasgkas Essential Instructions Read this page before proceeding! Emerson designs, manufactures and tests its products

More information

Quick Start Guide LIQ-QSG-Hx338, Rev M July Rosemount Hx338. Steam Sterilizable and Autoclavable ph Sensor

Quick Start Guide LIQ-QSG-Hx338, Rev M July Rosemount Hx338. Steam Sterilizable and Autoclavable ph Sensor Quick Start Guide LIQ-QSG-Hx338, Rev M July 2017 Rosemount Hx338 Steam Sterilizable and Autoclavable ph Sensor Safety Information WARNING! Do not exceed temperature and pressure limitations of 266 F (130

More information

Autocalibration Systems for In Situ Oxygen Analyzers

Autocalibration Systems for In Situ Oxygen Analyzers Product Data Sheet CMB_PDS_340AC_AutoCal Autocalibration Systems for In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging from one to four oxygen analyzers Can be easily

More information

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications 70-82-03-48 January 2003 Overview The DirectLine DL424/425 Sensor Modules are part of a family of products developed

More information

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes Xi Advanced Electronics for Zirconium Oxide Oxygen Probes Excellent accuracy Large backlit display and keypad NEMA 4X enclosure Works with Westinghouse/Rosemount, and most competitive ZrO 2 probes HART

More information

Flame Simulator: FS-IR-975. User Manual

Flame Simulator: FS-IR-975. User Manual Flame Simulator: FS-IR-975 User Manual 00809-0500-4975 Legal Notice The Flame Simulator described in this document is the property of Rosemount. No part of the hardware, software, or documentation may

More information

Quick Start Guide LIQ-QSG-Hx438, Rev A June Rosemount Hx438. Amperometric Steam Sterilizable Dissolved Oxygen Sensors

Quick Start Guide LIQ-QSG-Hx438, Rev A June Rosemount Hx438. Amperometric Steam Sterilizable Dissolved Oxygen Sensors Quick Start Guide LIQ-QSG-Hx438, Rev A June 2017 Rosemount Hx438 Amperometric Steam Sterilizable Dissolved Oxygen Sensors Safety Information WARNING! Do not exceed temperature and pressure limitations

More information

OPERATION MANUAL MODEL 8102 ACCELEROMETER

OPERATION MANUAL MODEL 8102 ACCELEROMETER OPERATION MANUAL TE CONNECTIVITY SENSORS/// 05/2016 Page 1 WARRANTY Measurement Specialties, Inc. accelerometers are warranted during a period of one year from date of shipment to original purchaser to

More information

OPERATION MANUAL MODEL & ACCELEROMETER

OPERATION MANUAL MODEL & ACCELEROMETER OPERATION MANUAL MODEL 8011-01 & 8021-01 ACCELEROMETER TE CONNECTIVITY SENSORS///MODEL 8011-01 & 8021-01 ACCELEROMETER 05/2016 Page 1 WARRANTY Measurement Specialties, Inc. accelerometers are warranted

More information

Dual Input ph/conductivity Analyzer

Dual Input ph/conductivity Analyzer Instruction Sheet PN 51A-1055pHC/rev.I January 2006 Model 1055 SOLU COMP II Dual Input ph/conductivity Analyzer Model Option 1055-22-30 For additional information, please refer to the Instruction Manuals

More information

Flame Simulator: FS-UVIR-975. User Manual

Flame Simulator: FS-UVIR-975. User Manual Flame Simulator: FS-UVIR-975 User Manual 00809-0800-4975 Legal Notice The Flame Simulator described in this document is the property of Rosemount. No part of the hardware, software, or documentation may

More information

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions 1.0 GENERAL INFORMATION Every SRH humidity sensor product is tested and calibrated before

More information

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2 APT2000 Series 2-Wire Contacting Conductivity Transmitters Overview The Honeywell Analytical Process Transmitter (APT) 2000 Series transmitter is a two-wire 24-Volt device that continuously measures conductivity,

More information

OPERATION MANUAL MODEL 4610 ACCELEROMETER

OPERATION MANUAL MODEL 4610 ACCELEROMETER OPERATION MANUAL MODEL 4610 ACCELEROMETER TE CONNECTIVITY SENSORS///MODEL 4610 ACCELEROMETER 05/2016 Page 1 WARRANTY Measurement Specialties, Inc. accelerometers are warranted during a period of one year

More information

High Pressure Conductivity Monitor

High Pressure Conductivity Monitor Product Data Sheet PDS 71-EDS880/1/rev.A August 2006 Model EDS880/1 High Pressure Conductivity Monitor COMPLETE SYSTEM FOR THE DETERMINATION OF CONDUCTIVITY IN HIGH PRESSURE SYSTEMS SENSOR INSTALLS DIRECTLY

More information

Dissolved Oxygen Sensors

Dissolved Oxygen Sensors Instruction Sheet PN 51A-HxDO/rev.E July 2005 Models Hx438 and Gx448 Dissolved Oxygen Sensors For additional information, please refer to the Instruction Manuals CD shipped with this product, or visit

More information

Dual Input Toroidal Analyzer

Dual Input Toroidal Analyzer Instruction Sheet PN 51A-1055T/rev.H February 2006 Model 1055 SOLU COMP II Dual Input Toroidal Analyzer Model Option 1055-21-31 For additional information, please refer to the Instruction Manuals CD shipped

More information

OPERATION MANUAL Model 8011 & mA

OPERATION MANUAL Model 8011 & mA OPERATION MANUAL Model 8011 & 8021 4-20mA TE CONNECTIVITY SENSORS/// MODEL 8011 & 8021 4-20MA 05/2016 Page 1 WARRANTY Measurement Specialties, Inc. accelerometers are warranted during a period of one year

More information

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications DL423 DirectLine Sensor Module for Conductivity Measurement Specifications 70-82-03-47 January 2003 Overview DirectLine DL423 for Conductivity measurement is a family of sensors released by Honeywell as

More information

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual GG-NH3-2% AMMONIA GAS SENSOR Installation and Operation Manual 2 GG-NH3-2% Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

Incutrol/2 Regulator

Incutrol/2 Regulator 12216-08 Model 2597A Incutrol/2 Regulator Hach Company, 1986-1996. All rights. reserved. Printed in the U.S.A. 05/95 13ed 09/96 rev2 2 Table of Contents Specifications...1 General Description...2 Setup...2

More information

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2 APT4000 Series 4-Wire Contacting Conductivity Analyzers Overview 70-82-03-45 10/03 Page 1 of 8 Specification The Honeywell Analytical Process Analyzer (APT) 4000 Series2 continuously measures conductivity,

More information

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes Xi Advanced Electronics for Zirconium Oxide Oxygen Probes Excellent accuracy Large backlit display and keypad NEMA 4X enclosure Works with Westinghouse/Rosemount, and most competitive ZrO probes HART communications

More information

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual GG-LEL2 COMBUSTIBLE GAS SENSOR Installation and Operation Manual 2 GG-LEL2 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 2090F Hygienic Pressure Transmitter Hygienic Pressure Transmitter Conforms to 3-A Sanitary s Features CIP/SIP service for process temperatures up to 284 F (140 C) Absolute or gage pressure ranges from 0-1.5 to 0-300 psi Mounts with either

More information

Rosemount 396/396VP/397/398/398VP

Rosemount 396/396VP/397/398/398VP Instruction Manual Rev. M Rosemount 396/396VP/397/398/398VP ph/orp Sensors hasgkas Essential Instructions Read this page before proceeding! Emerson designs, manufactures and tests its products to meet

More information

Dual Input ph/orp Analyzer

Dual Input ph/orp Analyzer Instruction Sheet PN 51A-1055pH/rev.I February 2006 Model 1055 SOLU COMP II Dual Input ph/orp Analyzer Model Option 1055-22-32 For additional information, please refer to the Instruction Manuals CD shipped

More information

Model 5190-F Temperature/Humidity Probe

Model 5190-F Temperature/Humidity Probe Model 5190-F Temperature/Humidity Probe FAA APPROVED ECP234 2017 Mar 13 NOT FAA APPROVED User s Manual Rev. C All Weather Inc. 1165 National Drive Sacramento, CA 95834 USA 800.824.5873 www.allweatherinc.com

More information

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions 138-EN Please read and save these instructions Contents General Safety Information... 3 Product Information...3-5 Product

More information

Inline Heater for Solvent or Gas. Installation and Operation Manual

Inline Heater for Solvent or Gas. Installation and Operation Manual SH Series Inline Heater for Solvent or Gas Installation and Operation Manual This instruction manual explains the basic operation of the Process Technology inline solvent or gas heater. We recommend reading

More information

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents GasGuard NH 3 2% General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6

More information

Multipurpose test lamp kit

Multipurpose test lamp kit Multipurpose test lamp kit Reference Manual Part Number: MAN-0131, rev. 4 Release: June 2016 Important Instructions Net Safety Monitoring, Inc (Net Safety) designs, manufactures and tests products to

More information

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual GG-VL-R REFRIGERANT VENT LINE SENSOR Installation and Operation Manual 2 GG-VL-R Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified

More information

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016 Rosemount 0085 Pipe Clamp Sensor Assembly 00825-0100-4952, Rev CA NOTICE This guide provides basic guidelines for Rosemount 0085 Pipe Clamp Sensor. It does not provide instructions for configuration, diagnostics,

More information

Installation, Operation & Service Manual

Installation, Operation & Service Manual Installation, Operation & Service Manual WARNING Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the Installation, Operation and

More information

High Temperature Remote Gas Calibrator

High Temperature Remote Gas Calibrator High Temperature Remote Gas Calibrator The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing

More information

Intrinsically Safe Transmitters, Option Code 2n

Intrinsically Safe Transmitters, Option Code 2n Installation Manual for Intrinsically Safe Transmitters, Option Code 2n ATEX PERSONAL INJURY WARNING DO NOT USE these products as safety or emergency stop devices or in any other application where failure

More information

Rosemount 4500 Hygienic Pressure Transmitter. Start

Rosemount 4500 Hygienic Pressure Transmitter. Start Quick Installation Guide June 2007 Rosemount 4500 Rosemount 4500 Hygienic Pressure Transmitter ProductDiscontinued Start Step 1: Mount the Transmitter Step 2: Set the Switches Step 3: Connect Wiring and

More information

5000TC Series Toroidal (Electrodeless) Conductivity Sensors. Specification. Overview. Features. Description /00 Page 1 of 8

5000TC Series Toroidal (Electrodeless) Conductivity Sensors. Specification. Overview. Features. Description /00 Page 1 of 8 TC Series Toroidal (Electrodeless) Conductivity Sensors Overview The Honeywell TC toroidal (electrodeless) conductivity sensor measures the conductivity of solutions from.2 to millisiemens/cm. The sensors

More information

RK / RK Methane Detector Operator s Manual

RK / RK Methane Detector Operator s Manual 61-1006RK / 61-0192RK Methane Detector Operator s Manual Part Number: 71-0228RK Revision: 0 Released: 10/29/18 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

Model 5190-E Temperature/Humidity Probe

Model 5190-E Temperature/Humidity Probe Model 5190-E Temperature/Humidity Probe User s Manual Rev. D All Weather Inc. 1165 National Drive Sacramento, CA 95834 USA 800.824.5873 www.allweatherinc.com Copyright 2010, All Weather, Inc. All Rights

More information

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual GG-CO-EXP CARBON MONOXIDE SENSOR Installation and Operation Manual 2 GG-CO-EXP Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by

More information

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents GasGuard H 2-1% General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6 Operation..

More information

Environmental Monitoring SmartSlot Card

Environmental Monitoring SmartSlot Card Environmental Monitoring SmartSlot Card AP9612TH Installation and Quick Start Manual Contents Introduction............................. 1 Overview 1 Product inventory 1 Safety notice 2 Your inspection

More information

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL GASGUARD LEL 3 Ammonia Sensor OPERATING & INSTALLATION MANUAL GasGuard LEL 3 Operating and Installation Manual 2 Table of Contents 3GasGuard LEL Operating and Instruction Manual General description. 4

More information

RK-03 Hydrogen Detector Operator s Manual

RK-03 Hydrogen Detector Operator s Manual 61-1001RK-03 Hydrogen Detector Operator s Manual Part Number: 71-0371 Revision: P1 Released: 5/26/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating detector.

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual Warning Use this product only in the manner described in this manual. If the equipment is used in a

More information

Quick Start Guide , Rev. BB February Rosemount 1495 Orifice Plate Rosemount 1496 Orifice Flange Union

Quick Start Guide , Rev. BB February Rosemount 1495 Orifice Plate Rosemount 1496 Orifice Flange Union 00825-0100-4792, Rev. BB Rosemount 1495 Orifice Plate Rosemount 1496 Orifice Flange Union NOTICE This installation guide provides basic guidelines for Rosemount 1495 Conditioning Orifice Plate. It does

More information

RK-02 Multi Point Detector Operator s Manual

RK-02 Multi Point Detector Operator s Manual 65-2485RK-02 Multi Point Detector Operator s Manual Part Number: 71-0237RK Revision: A Released: 11/26/14 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual

More information

Next Generation Corona Discharge Auto Voltage Sensing Installation Manual

Next Generation Corona Discharge Auto Voltage Sensing Installation Manual Next Generation Corona Discharge Auto Voltage Sensing Installation Manual 4-2122-01 Rev.B IMPORTANT SAFETY INSTRUCTIONS When installing and operating the Spa Eclipse ozone generator, basic precautions

More information

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL GASGUARD H2S EXP Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual Warning Use this product only in the manner described in this manual. If the equipment is used

More information

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL GASGUARD Cl 2 Chlorine Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual 2 Table of Contents GasGuard Cl 2 Operating and Instruction Manual General description. 4 Installation..

More information

RK Multi Point Detector Operator s Manual

RK Multi Point Detector Operator s Manual 65-2480RK Multi Point Detector Operator s Manual Part Number: 71-0198RK Revision: C Released: 11/26/14 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual before

More information

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014 Rosemount Pipe Clamp Sensor Reference Manual Reference Manual Title Page The Rosemount 0085 Pipe Clamp Sensor NOTICE Read this manual before working with the product. For personal and system safety, and

More information

OPERATION MANUAL MODEL 805 ACCELEROMETER

OPERATION MANUAL MODEL 805 ACCELEROMETER OPERATION MANUAL MODEL 805 ACCELEROMETER TE CONNECTIVITY SENSORS /// MODEL 805 ACCELEROMETER 05/2016 Page 1 WARRANTY Measurement Specialties, Inc. accelerometers are warranted during a period of one year

More information

RK/ RK Oxygen Detector Operator s Manual

RK/ RK Oxygen Detector Operator s Manual 65-2502RK/65-2510RK Oxygen Detector Operator s Manual Part Number: 71-0074RK Revision: A Released: 3/1/11 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating detector.

More information

MEAS CAL ALARM WASH CONF APT4000 TC

MEAS CAL ALARM WASH CONF APT4000 TC APT4000 Series Toroidal Conductivity Transmitters Overview 70-82-03-42 3/01 Page 1 of 8 Specification The Honeywell Analytical Process Transmitter (APT) 4000 Series transmitter continuously measures conductivity,

More information

CLARITY II TURBIDIMETER

CLARITY II TURBIDIMETER Product Data Sheet PDS 71-T1055/rev.J January 2006 Model T1055 CLARITY II TURBIDIMETER COMPLETE SYSTEM includes single or dual input analyzer, sensor(s), and debubbler assembly CHOOSE U.S. EPA METHOD 180.1

More information

Installation and Operating Instructions

Installation and Operating Instructions The Leader of RF and Sonic Level For Assistance Call 1-800-527-6297 Outside North America 1-215-674-1234 Installation and Operating Instructions Series 504-1200 Ultrasonic VeriGAP Switch using 404-1200

More information

ion Genesis Pump Controller

ion Genesis Pump Controller High Water Alarm Document No.: IONG_OM Page 1 of 7 Table of Contents Safety Precautions.......................... 1 General Overview.......................... 1 Installation.................................2

More information

RK / RK CO 2 Detector Operator s Manual

RK / RK CO 2 Detector Operator s Manual 61-1004RK / 61-0191RK CO 2 Detector Operator s Manual Part Number: 71-0145RK Revision: C Released: 10/29/18 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating detector.

More information

Drain Cooler Water tempering device

Drain Cooler Water tempering device Water tempering device Installation instructions & user manual READ AND SAVE THESE INSTRUCTIONS DC-EN/151214 Foreword Foreword 1. These installation instructions and operation manual have been developed

More information

RK-05 Combustible Gas Transmitter Operator s Manual

RK-05 Combustible Gas Transmitter Operator s Manual 65-2405RK-05 Combustible Gas Transmitter Operator s Manual Part Number: 71-0180RK Revision: 0 Released: 2/16/11 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction

More information

Toroidal (Electrodeless) Conductivity Sensors Series 5000TC Specifications

Toroidal (Electrodeless) Conductivity Sensors Series 5000TC Specifications Toroidal (Electrodeless) Conductivity Sensors Series TC Specifications 7-82-3-37 June Overview The Honeywell TC toroidal (electrodeless) conductivity sensor measures the conductivity of solutions from.2

More information

Model /8320CRP Shower and Eye/Face Wash

Model /8320CRP Shower and Eye/Face Wash INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 8320-8325/8320CRP Shower

More information

Rosemount 3900/3900VP

Rosemount 3900/3900VP Rosemount 3900/3900VP General Purpose ph/orp Sensor Instruction Manual LIQ-MAN-3900 Rev. G April 2017 hasgkas Essential Instructions Read this page before proceeding! Emerson designs, manufactures, and

More information

OPERATOR S MANUAL SF-12 AND SF12A HI VOLUME WATER HEATER

OPERATOR S MANUAL SF-12 AND SF12A HI VOLUME WATER HEATER OPERATOR S MANUAL SF-12 AND SF12A HI VOLUME WATER HEATER MODELS SF12-A PICTURED Page 1 of 12 Table of Contents Safety Precautions Section 1. Section 2. Section 3. Section 4. Section 5. Section 6. Systems

More information

Explosion Proof Line Powered Telephone Ringer

Explosion Proof Line Powered Telephone Ringer Explosion Proof Line Powered Telephone Ringer P7020 CE20 Without Projection Horn P7021 CE20 With Projection Horn P004572 Rev. E 180416 4/16/2018 12:32 PM Ph: 403.258.3100 \ email:info@guardiantelecom.com

More information

Figure 1 DirectLine DL423 Sensor. Description, continued

Figure 1 DirectLine DL423 Sensor. Description, continued DL423 DirectLine Sensor Module for Conductivity Measurement Overview 70-82-03-47 1/03 Page 1 of 8 Specification DirectLine DL423 for Conductivity measurement is a family of sensors released by Honeywell

More information

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters TPI Corporation P.O. Box 4973 Johnson City, TN 37601 www.tpicorp.com OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters *EXCLUDING RESIDENCES IMPORTANT SAFETY INFORMATION INSIDE possible

More information

Figure 1 DirectLine DL423 Sensor. Description, continued

Figure 1 DirectLine DL423 Sensor. Description, continued DL423 DirectLine Sensor Module for Conductivity Measurement Overview 70-82-03-47 4/02 Page 1 of 8 Specification DirectLine DL423 for Conductivity measurement is a family of sensors released by Honeywell

More information

EOS. Instruction Manual. 120V High Amperage Digital Humidity Controller. Part #

EOS. Instruction Manual. 120V High Amperage Digital Humidity Controller. Part # EOS 120V High Amperage Digital Humidity Controller Instruction Manual Part # 702603 www.titancontrols.net 120V High Amperage Digital Humidity Controller Warnings and Cautions Factory Settings Eos 120V

More information

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

SmartPower Solutions. Quick Start Guide , Rev CA March 2015 SmartPower Solutions 00825-0100-4701, Rev CA NOTICE This guide provides basic guidelines for the SmartPower family of products. It does not provide instructions for detailed configuration, diagnostics,

More information

RATIO:GUARD Model E-1S EC Monitor

RATIO:GUARD Model E-1S EC Monitor EC probe Probe tees Probe retention clips Temperature probe E-1S monitor box UNPACKING Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing

More information

Remote Relay Module (RRM)

Remote Relay Module (RRM) Remote Relay Module (RRM) Instruction Manual WARNING THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR INSTALLING, USING OR SERVICING THIS PRODUCT. Like

More information

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage FEATURES Weldable and Threaded Process Fittings -40ºC to +125ºC Operating Temperature ±0.1% Pressure Non Linearity Solid State Reliability APPLICATIONS Medical Instruments Process Control Fresh & Waste

More information

RK-05 Carbon Monoxide Detector Operator s Manual

RK-05 Carbon Monoxide Detector Operator s Manual 65-2433RK-05 Carbon Monoxide Detector Operator s Manual Part Number: 71-0189RK Revision: 0 Released: 5/17/11 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual

More information

1228s Multidrop INSTRUCTIONS. Installation and Operation of the AMC-1228s Electrochemical Sensor Module For Use With Multidrop AMC Monitors

1228s Multidrop INSTRUCTIONS. Installation and Operation of the AMC-1228s Electrochemical Sensor Module For Use With Multidrop AMC Monitors 228s Multidrop INSTRUCTIONS Installation and Operation of the AMC-228s Electrochemical Sensor Module For Use With Multidrop AMC Monitors IMPORTANT: Please read these installation and operating instructions

More information

MN908 No. 282C Replaces 282B LB7013

MN908 No. 282C Replaces 282B LB7013 No. 282C Replaces 282B LB7013 Instruction Manual For Baldor Dust Control Units Models DC7, DC7 3, DC8, DC8 3, DC10, DC10 3, DC12, DC12 3 and DC14 3. For use on Grinders mounted to GA16 and GA20 pedestals

More information

CONTROL BE MADE CHANGES MAY NOT. Page 1

CONTROL BE MADE CHANGES MAY NOT. Page 1 HI 6020IT and HI 6020JB US & Canada Hazardous Locations User Guide (Class I, II, III, Division 1, Class I, Zone 0 and Zone 20) Hardy Process Solutions Document Number: : 0596-0352-01 REV A CONTROL LLED

More information

www.titancontrols.net Warnings & Cautions Zephyr 3 - Heating/Cooling Controller Instructions for Operation Troubleshooting Tips Controller Specifications Installation Example Warranty Information Service

More information

Preamplifier Power Supply PPS-02 user's guide

Preamplifier Power Supply PPS-02 user's guide Preamplifier Power Supply PPS-02 user's guide 1 Table of contents 1. Warranty... 3 2. PPS-02 overview... 4 2.1. PPS-02 parameters... 4 2.2. Coding the symbol of the power supply...4 2.3. PPS-02 physical

More information

RK/ RK Oxygen Detector Operator s Manual

RK/ RK Oxygen Detector Operator s Manual 65-2494RK/65-2497RK Oxygen Detector Operator s Manual Part Number: 71-0179RK Revision: 0 Released: 2/16/11 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating detector.

More information

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Rosemount 3490 Series 4 20 ma + HART Compatible Controller 00825-0200-4841, Rev AB Rosemount 3490 Series 4 20 ma + HART Compatible Controller Failure to follow safe installation guidelines could result in death or serious injury The Rosemount 3490 Series Control

More information

RK Carbon Monoxide Transmitter Operator s Manual

RK Carbon Monoxide Transmitter Operator s Manual 65-2335RK Carbon Monoxide Transmitter Operator s Manual Part Number: 71-0177RK Revision: 0 Released: 4/12/11 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual

More information

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web:   IMPORTANT!!! 10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX 77041-4051 VOICE (713) 973-6905 FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN

More information

Net Safety ST3 XChem Toxic Gas Sensor

Net Safety ST3 XChem Toxic Gas Sensor Product Data Sheet 00813-0100-4303, Rev AA Net Safety ST3 XChem Toxic Gas Sensor Millennium II Series Sensors Net Safety ST3 Overview The Net Safety ST3 XChem series of electrochemical toxic gas sensors

More information

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide Miniature Thermoelectric Cooler Controller MTCC-01 user's guide 1 Table of Contents 1. Warranty... 3 2. MTCC-01-xxx overview... 4 2.1. MTCC-01-xxx specification... 4 2.2. TE cooled detector temperature

More information

XT Series Thermostats

XT Series Thermostats ISO 9001 Explosion-Proof & Moisture Resistant XT Series Thermostats Installation, Operation, & Maintenance Instructions XTWA Thermostat XTWL Thermostat XTB Thermostat Part No.MI133.Rev.2.00 Date of Issue:

More information

Ozone + UV Sanitation

Ozone + UV Sanitation Ozone + UV Sanitation Installation Manual 4-2177-01 Rev.C IMPORTANT SAFETY INSTRUCTIONS When installing and operating the DEL Spa Solar Eclipse, basic precautions should always be followed: READ AND FOLLOW

More information

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description APT4000 Series 4-Wire ph Transmitters 3/01 Page 1 of 8 Specification Overview The Honeywell Analytical Process Transmitter (APT) 4000 Series transmitter continuously measures ph or ORP in industrial processes

More information

Mark 25 Ultrapure Water Conductivity Analyzer

Mark 25 Ultrapure Water Conductivity Analyzer Martek Instruments, Inc. Mark 25 Ultrapure Water Conductivity Analyzer Instruction Manual WARRANTY POLICY Unless otherwise stated, MARTEK INSTRUMENTS, INC. warrants this equipment to be free from defects

More information

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description APT4000 Series 4-Wire ph Analyzers 70-82-03-44 10/03 Page 1 of 8 Specification Overview The Honeywell Analytical Process Analyzer (APT) 4000 Series 2 continuously measures ph or ORP in industrial processes

More information