time SWITCH hour time clock Art.-No

Similar documents
For the user / for the installer. Instructions for Use and Installation. time SWITCH hour time clock

For the heating engineer. Installation manual. Interface 0-10V VR34

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

Programmable Thermostat with Plug in RF Boiler Control Model: ST620VBC INSTRUCTION MANUAL

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

Digital Room Thermostat

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

Supplement to operating and installation manual no for the VR 81 remote control unit

The guarantee on this appliance is valid for 12 months from the first day of installation.

RF Programmable Room Thermostat Installation Instructions

Installation & User Instructions

425 Coronet Electro-mechanical Timeswitch User Operating Instructions

RT021 User and Installation Instructions

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

Mynute. Standard efficiency system boiler 12e - 16e - 20e. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Operating instructions

For the operator/for the heating engineer. Operating and Installation Manual VRC 430. Weather compensator VRC 430

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

Operating instructions

Programmable Room Thermostat Installation Instructions

Mikrofill Ethos Condensing combination boiler

OIL FILLED RADIATOR Instruction manual

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

Room-temperature (economy/night) unit TR 212 E

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

For the owner and the heating engineer. Operating and Installation Manual. timeswitch 140. Two-channel 5/2 or 7-day full programmer

Installation and User Guide. Electro-mechanical 24 hour timeswitch for controlling hot water and heating (Including Factory Replacement Units FRU)

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

Model: Available in : Sapphire Black and Glacier White. 1 Series

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

Self-learning Room Temperature Controller

Operating and Installation Manual VRC 430f. Weather compensator controller with radio transmission. For the operator / for the heating engineer

User Operating Instructions Horstmann 425 Tiara/Diadem Electro-mechanical Programmers

Mixer module VR 61. Operating and Installation Manual. Mixer module for VRC 430 / VRC 430f

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

User's Instructions. Alpha CB50

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

ES3247B. 3 Channel Programmer. User and Installation Instructions

RF Programmable Room Thermostat User Instructions

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

OWNER S MANUAL. Evaporative Cooler. (English) (EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY

Model: RT510RF. Installation Manual

DAY/TIME Button: Selects hour, minute and day setting.

Digital Electronic Thermostat With RF

Installation, operating and servicing instructions

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

End User Manual ACO 35 MFFI COMBI

ESRTP4RF. RF Programmable Room Thermostat with TPI, Optimum Stop, Delayed & Optimum Start. User and Installation Instructions

User Guide. Gold Combi Condensing Combination Boiler

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi

Operating Instructions Model : HC HC-N

ES-LCD User Control SD Card Location

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Electronic Dual Cylinder Thermostat Installation Instructions

CentaurPlus C21 Series 2 User Operating Instructions

CentaurStat 7 User Operating Instructions Central Heating Programmable Room ThermoStat

/09.15_00. De Longhi Appliances via Seitz, Treviso Italia

DUO PLUS. Instruction manual

Battery Powered Electronic Programmable Room Thermostat

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

WARNING Important Safety Information

CoziStat. 1. Introduction and Brief Description COZISTAT INSTALLATION I NSTRUCTIONS &OPERATING MANUAL

Cat. No TPT44. Installation & Operating Instructions

E-COMBI EVO E-SYSTEM EVO

Digital Electronic Thermostat With RF

VR 90 Remote control unit

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

WARNING Important Safety Information

Electronic timeswitch

CentaurPlus C27 Series 2 User Operating Instructions

SERIES. End User Manual ACO 27 MFFI G.C.N: ACO 32 MFFI G.C.N: ACO 27 RFFI G.C.N: ACO 32 RFFI G.C.

Baxi Maxflow Combi FS

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

Battery Powered Electronic Room Thermostat Cat. No. TRT033

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

atmocraft VK 654/9-1654/9 DE/AT/GB/CZ/SK/HU/PL/HR/SI/SCG

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

Model: Available in: Sapphire Black and Glacier White. 1 Series

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

Maincor Air Temperature Controls AIR TEMPERATURE CONTROL

condens Instructions for Use Betacom 2 24 G.C. No Betacom 2 28 G.C. No

User Manual - Energenie MiHome etrv

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

CentaurPlus ZW and HRT4-ZW

LC2200 Level Controller Installation and Maintenance Instructions

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

Quick start guide. Connected wireless room thermostat. Logic Combi C / Logic Max Combi C / Vogue Gen 2 Combi / Vogue Max Combi

PROGRAMMABLE 7-DAY THERMOSTAT

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

Transcription:

24h Timeclock 11.04.2001 9:05 Uhr Seite 1 time SWITCH 110 Art.-No. 306 741 24 hour time clock All Vaillant boilers have a built in frost thermostat. This time clock is not suitable for use with an external frost thermostat.

24h Timeclock 11.04.2001 9:05 Uhr Seite 2 int Inhalt Contents Nomenclature Inhoud Indice I E int 24 hour time clock Operating instructions page 4-9 Installation instructions page 10-12 Temporizzatore 24 ore Istruzioni per l uso pagina 14-19 Istruzioni per l installazione pagina 20-22 Reloj temporizador 24 horas Instrucciones de uso página 24-29 Instrucciones de montaje página 30-32 Abb., Fig., Afb. Seite, page, Pag. 3, 34 37 2

24h Timeclock 11.04.2001 9:05 Uhr Seite 3 int Fig. 1 1 3 4 5a 2 5b 6 Fig. 1: 3

24h Timeclock 11.04.2001 9:05 Uhr Seite 4 1 Operating Summary 1 Indicator light 2 Operating mode switch The time is controlled as follows: Heating constantly off Heating constantly on Automatic heating programme 3 Minute hand* For showing and setting the time 5a 5b Slide in the tappets* Tappet in = = heating on Slide out the tappets* Tappet out = = heating off 6 Time fo day The time of day can be read opposite the reference triangle (4). Please note that the time of day is given using a 24 hour clock. 4 Reference triangle* Indicates the time of day e.g. Fig. 1 15.00 * The timer with the minute hand (3) and the tappets (5a, 5b) are accessible after opening the inspection window. 4

24h Timeclock 11.04.2001 9:05 Uhr Seite 5 Contents 1 Operating summary 4 2 Selecting of the operating mode 6 3 Setting the timer 7 4 Programming heating periods 8 5 Special operating conditions 9 6 Installation instructions 10 7 Commissioning 11 8 Technical data 12 5

24h Timeclock 11.04.2001 9:05 Uhr Seite 6 2 Selecting of the operating mode 2.1 Selecting the operating mode In position, the heating is constantly off With the operating mode switch fig. 1 (2), you can adapt the operating mode of your heating system according to your personal needs. In position, the heating operates automatically depending on the setting of the tappets. In position, the heating is constantly on. 6

24h Timeclock 11.04.2001 9:05 Uhr Seite 7 3 Setting the timer 3.1 Setting the timer 3.1.1 Reading time of day The time of day can be read on the clock face below the reference triangle. Note: The timer uses a 24 hour clock scale. 3pm is therefore 15:00. 3.1.2 Setting the timer Open the inspection window of the timer. Turn the minute hand clockwise until the reference triangle coincides with the correct time of day. 7

24h Timeclock 11.04.2001 9:05 Uhr Seite 8 4 Programming heating periods 4.1 Setting the tappets Set the tappets (5a) and (5b) as follows: For heating on periods press the tappets (5a) inwards. 4.2 Setting the heating programme Open the inspection window of the timer. Set the tappets (4) and (5) according for your heating requirements. For heating off periods press the tappets (5b) outwards. 8

24h Timeclock 11.04.2001 9:05 Uhr Seite 9 5 Special operating conditions 5.1 Weekend operation If, for example, during the weekend, the heating is to be switched on temporarily, turn the operating mode switch (2) to the position. To return to automatic operation, turn the operating mode switch back to position. 5.2 Summer-time operation Set the operating mode switch (2) to the position. This turns off the heating system. 5.3 Operating and mains failure For environmental protection reasons the programmer contains no batteries. The timer comes to a stand still if the mains power fails. However, the programme you have entered is retained. When the mains power returns, the heating programme continues automatically. The time of day must be corrected accordingly. Using the minutes hand (3) set the current time of day as previously described. 9

24h Timeclock 11.04.2001 9:05 Uhr Seite 10 6 Installation instructions 6 Installation instructions All electrical work shall be undertaken by a competent person and shall comply with BS 7671 (IEE Regulations). Turn off the boiler. Isolate the electrical supply to the boiler Open lower control cover (if fitted) Lower electronic control box by turning securing screws 90 and lowering fascia panel. Release the time clock blanking plate from the control box by pushing the retaining clip (situated on the right hand side, at the rear of the control box above the pressure gauge) to the left and pulling the blanking plate from the front of the control box. Raise and secure the control box into position. Locate the four pins on the rear of the programmer and gently push the programmer until it locks into position. Recommission the boiler. 10

24h Timeclock 11.04.2001 9:05 Uhr Seite 11 7 Commisssioning 7 Commissioning Turn on the electrical supply to the boiler and timer and commission as detailed in the instructions for installation supplied with the boiler. The CE Mark demonstrates that the room thermostat fulfills the essential requirements of the Low Voltage Directive (73/23/EEC). We do not accept any liability for damage airing from non-observance of these instructions. 11

24h Timeclock 11.04.2001 9:05 Uhr Seite 12 8 Technical data Appliance type Article no. Operating voltage Current input Dimensions: Width/Height/Depth Weight Protection class Type of enclosure Permissible storage temperature 24 hour time clock 306741 16...30 V DC 10 ma 148 mm/85 mm/29 mm approx. 200 g IP 20 II 5...+60 C 12