Agilent 1290 Infinity II Online SPE Solution

Similar documents
Agilent InfinityLab Online SPE Solution

InfinityLab Quick-Connect Bio-inert Heat Exchanger

Enhancing Throughput of Online SPE Analysis of Pesticides in Wastewater The Agilent 1200 Infi nity Series Online SPE Solution

High Volume Injection up to 5 ml with the Agilent 1200 Infinity Series Online SPE Solution for Highest Sensitivity

Installation of Hotel Drawers

Application Note. The Agilent 1200 Infinity Series Online SPE Solution for the Highest Sensitivity. Author. Abstract.

On Line SPE LC/MS/MS Applications

Analysis of Pharmaceuticals and Personal Care Products in Groundwater by Online SPE and LC/MS/MS

Rapid Quantification of Polar and Semipolar Pesticide Metabolites with Combined Online SPE and Direct Injection

Customers should provide all necessary operating supplies upon request of the engineer.

ACQUITY UPLC HT Column Heater Instructions

On-line SPE Enrichment of Trace Organic Contaminants in Water and Juices

Agilent 1290 Infinity II Vialsampler Data Sheet

The Complete and Easy Guide to Configuring Your Specific Thermo NanoLC for Mass Spec Analysis

Systems. Visit us at

Installing the 30-cm Column Heater/Cooler

Application Note. Authors. Abstract

GE Healthcare. Mixer M-925. Instructions

An Advanced Heat Exchanger for the Agilent 1290 Infinity Thermostatted Column Compartment

Agilent 1100 Series Refractive Index Detector. Reference Manual

Optimizing the Performance of the Agilent 1290 Infinity Evaporative Light Scattering Detector

Agilent 1100 Series Autosampler Thermostat Reference Manual

Agilent 1290 Infinity Thermostat

Agilent Vac Elut SPS 24 Manifold User Guide

Eldex Column Heater. Operator s Manual

Agilent 1260 Infinity Multi-Detector Suite

Spark Holland introduces

Direct Injection and Online SPE LC/MS/MS for the Determination of Pharmaceuticals and Personal Care Products (PPCPs) in Water Samples

Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples

ACQUITY UPLC H-Class Column Compartments Operator s Overview and Maintenance Information

Platen Heater Pad Replacement

940 Professional IC Vario

Mariner Microspray and Low-Flow Electrospray Fused Silica Spray Tip and Capillary Kit. Operating Instructions. 1 Product Description.

Tool-free LC connections for HPLC, UHPLC and nano LC systems

Chromatography. Research Supplies. 2014/2015 Catalog

Universal NanoFlow Sprayer Installation and Maintenance Guide

Installing a Fast Oven Upgrade Kit

AppNote 6/2008. Automated SPE and Fast GC-ECD Analysis of PCBs in Waste Oil KEYWORDS ABSTRACT INTRODUCTION. MACH, Fast GC-ECD, SPE, PCB, waste oil

930 Compact IC Flex. 930 Compact IC Flex Oven SeS/PP/Deg. Manual Short Instructions EN /

Agilent 1200 Series Variable Wavelength Detector

DART-Thermo LTQ/Orbitrap Interface Manual

Waters 2695 Separations Module

Wide-Bore Heat Exchanger Installation Kit ( )

SERVICE MANUAL. 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and Model

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

DETERMINATION OF PAH In Particulate Matter PM 10 with SPE/EVAporation

Automated Sample Preparation: SPE GPC - EVAporation SUPERIORITY BY ADAPTATION. Visit us at

Pre-Fab Easy Installation For Model 0011-CF-USK Installation and Operating Instructions for Existing Homes Or Buildings with Standard Piping

Agilent 1100 Series Variable Wavelength Detector. Reference Manual

Service package PDAD- -SP (en) Assembly instructions d [ ]

INSTALLATION INSTRUCTIONS

MFE400 SERVICE PARTS

Automação de SPE utilizando sistema robótico Triplus RSH autosampler. Nova Analitica

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Sanitise Syrup Lines & Valves. Taylor PH61 Cleaning every 14 days

Agilent 1200 Series Fluorescence Detector

Agilent 1200 Infinity Series ELSD

Waters 2695D Separations Module

Sensitive Determination of Microcystins from Environmental Waters Using On-Line SPE

* If the infiniti UV Water Treatment System has an S2 Starter, it is fully interchangeable with the UV Lamp with Glow Starter.

This document is a preview generated by EVS

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST CHEVROLET NOVA

Agilent 6400 Series. Maintenance Guide. Agilent Technologies

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

Metering & Thrust Gear Pumps. apompe.eu

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

Operating Instructions

Methods of solid phase extraction. Methods of solid phase extraction

Instruction Sheet. DANGER Indicates a potentially or imminently hazardous situation which, if not avoided, will result in death or serious injury.

SAMPLE PREPARATION ACCESSORIES

Polymer Dilution Blend and Feed Specifications For General Use

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2

Solid Phase Extraction using the 96-well Format ISOLUTE -96 Fixed Well Plates and ISOLUTE Array 96-well Plates

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

Agilent 1200 Infinity Series ELSD

CryoFit. Handling of Flow Cell and Capillaries. User Guide. Version 002

DETERMINATION OF PAH In Particulate Matter PM10 With SPE/EVAporation

Cube Triplel Concealed Thermostatic Shower. Telephone Product Specification. Cleaning

Repair Parts List DRYER MODEL NUMBER MDG30MNAWW. When requesting service or ordering parts, always provide the following information:

VPMmini. Operator's Manual

TCD-to-FID Series Connection on a 6820 GC, Accessory G4319A

NHR-25 Feed Hopper with Agitator

Customised HPLC Systems for Highest Performance

Thermo Scientific Rocket Evaporator. Revolutionary solvent evaporation complete laboratory workflow

AUC Cell Washer. User Manual

Installation, commissioning and servicing instructions

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST PLYMOUTH BELVEDERE

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y LS BARGE PUMP. Vertical high-flow pump

JSB is an authorised partner of DETERMINATION OF THE HYDROCARBON-INDEX DIN EN ISO :2000. i n s p i r a t i o n m e e t s i n n o v a t i o n!

SAMPLE MANUAL - INSTALLATION - FOR REFERENCE ONLY. ChemScan mini Analyzer. Parameter. Method #### Installation, Operation & Maintenance Manual

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS

Agilent 1100 Series Diode Array and Multiple Wavelength Detectors. Reference Manual

1 L Rotary Vacuum Evaporator Instruction Manual

Adsorption dryer PDAD. (en) Operating instructions g [ ]

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1

Service Documentation Market Release 7/84. Braun Kitchen machine KM 32 B 4209 with lamp

Thermo Scientific. TRACE GC Ultra. Gas Chromatograph Maintenance and Troubleshooting Manual. PN , Revision March 2011

HKF 8180 Operating instructions

Thermo-Finnigan LCQ Interface Manual

Transcription:

Agilent 1290 Infinity II Online SPE Solution Instruction Agilent Online-SPE-Solution - Instruction Technical Information about the Agilent Online-SPE-Solution (optional setups with: G4242A Online-SPE Starter Set, G4743A Online-SPE Multi Cartridge Kit, G4744A Online-SPE Direct Inject Kit, G4745A Online-SPE High Volume Injection Kit) Contents Typical Applications 2 G4742A Online-SPE Starter Kit 2 G4744A Online-SPE Direct Inject Kit 3 G4743A Online-SPE Multi Cartridge Kit 5 Delivery Checklist 7 Online-SPE-Solution Setup 9 Setting up the Starter Kit G4742A 9 Setting up the Direct Inject Kit G4744A 11 Setting up the SPE Multi Cartridge Kit G4743A 13 Installing the Valve Heads 15 Valve Head Parts Information 19 Agilent Technologies

Typical Applications G4742A Online-SPE Starter Kit Typical Applications G4742A Online-SPE Starter Kit The Agilent 1290 Infinity II Online SPE Solutions are based on the 1290 Infinity Flexible Cube that houses re-usable SPE (solid phase extraction) cartridges and up to two valves. Combined with the Agilent 6400 Series Triple Quadrupole mass spectrometer the 1290 Infinity II Online SPE Solution allows ultra-low, trace-level detection. The G4742A Online-SPE Starter Kit builds the basis for all possible Online-SPE solutions. Figure 1 Flow path in an Online-SPE Starter Kit setup 2

Typical Applications G4744A Online-SPE Direct Inject Kit G4744A Online-SPE Direct Inject Kit In addition to the Online SPE Starter set G4742A the online SPE direct injection kit G4744A allows also to bypass the SPE cartridges and instead inject directly onto the analytical column. Figure 2 Direct Injection (Valve A in Position 1) Valve A (left) in position 2 connects the flow path to valve B (right). From valve B, SPE cartridges can be chosen for either loading or elution. 3

Typical Applications G4744A Online-SPE Direct Inject Kit Figure 3 Valve A in Position 2 and Valve B in Position 1 Figure 4 Valve A in Position 2 and Valve B in Position 2 4

Typical Applications G4743A Online-SPE Multi Cartridge Kit G4743A Online-SPE Multi Cartridge Kit The Agilent 1290 Infinity II Online SPE Solution offers a method development kit for online SPE cartridges. This Online SPE Multi-Cartridge Kit (G4743A) is based on the Online SPE Kit (G4742A) and is recommended in combination with the Direct Injection Kit (G4744A). It adds a column selection valve (6-position/14-port valve head, 600 bar) for SPE method development. This 6-position/14-port valve is installed next to the 1290 Infinity Flexible Cube in an external valve drive. The Flexible Cube itself hosts two 2-position/10-port valves to support direct injections and online SPE. Figure 5 Flow path of the direct injection run The Agilent 1290 Infinity Flexible Cube offers the possibility of direct injections and online SPE. In Figure 5 on page 5, the flow path of the direct injection run is shown. In this position, the right 2-positon/10-port valve and the additional 6-column selection valve in the external valve drive are disabled and not busy. With the built-in solvent selection valve in the 1290 Infinity Flexible Cube, up to three solvents can be used to condition and to regenerate the cartridges ( Figure 6 on page 6). Also, the right 2-position/10-port valve can be switched between online SPE and bypass, for cleaning the system. 5

Typical Applications G4743A Online-SPE Multi Cartridge Kit Figure 6 Flow path for online SPE For online SPE, the flow path of the Agilent 1290 Infinity Flexible Cube goes through the left and right 2-position/10-port valve and afterwards to the 6-column selection valve. One out of the six cartridges is loaded with the sample. Figure 7 Flow path to elute the loaded cartridge To elute the loaded cartridge in the previous step (Figure 6 on page 6), the right 2-position/10-port valve is switched. NOTE Additional information can be found in Online SPE Multi-Cartridge Kit for Fast and Easy Method Development - The Agilent 1200 Infinity Series Online SPE Solution (5991-4005EN). 6

Delivery Checklist G4743A Online-SPE Multi Cartridge Kit Delivery Checklist Check the content of the delivery. You should have received the following: G4742A Online-SPE Starter Set p/n Description 5067-4145 2pos/10port valve head 600 bar 5067-4294 Online SPE Capillary Starter Kit Online SPE Capillary Starter Kit (5067-4294) # p/n Description 2 0890-1713 Tube PTFE, 2 m 2 0100-1516 Fitting male PEEK, 2/pk 1 5982-1271 BE online PLRP-S 15 20 µm2.1 mm x 12.5 mm 3/pk 1 G1329-87300 Capillary 0.17 mm, 900 mm 1 G1316-87319 Capillary ST 0.12 mm x 340 mm S/S 2 5067-4670 Capillary ST 0.17 mm ID 600 mm pre-swaged 1 5065-9979 Capillary ST 0.25 mm x 250 mm 5 01090-87308 Capillary ST, 0.25 mm x 130 mm 1 5065-9967 Fitting screw extra long 10/pk 1 G4742-90101 Online - SPE Kits Technical Note 1 G4742-60000 CD with online SPE method G4744A Online-SPE Direct Inject Set p/n Description 5067-4145 2pos/10port valve head 600 bar 5067-4295 Online-SPE Direct Inject Kit Online SPE Direct Inject Capillary Kit (5067-4295) # p/n Description 2 5043-0277 Plug Black Long 10-32 1 0100-1516 Fitting male PEEK, 2/pk 1 01090-87308 Capillary ST, 0.25 mm x 130 mm 1 5022-6508 Capillary, 0.25 mm x 280 mm no fittings 2 5021-1822 Capillary, 0.12 mm x 280 mm 1 G1316-87319 Capillary ST 0.12 mm x 340 mm S/S 1 G4742-90101 Online - SPE Kits Technical Note 1 G4742-60000 CD with online SPE method 7

Delivery Checklist G4743A Online-SPE Multi Cartridge Kit G4743A Online-SPE Multi Cartridge Set p/n Description 5067-4146 6pos/14port valve head In combination with the G4744A Online-SPE direct Injection kit a 3rd valve drive is needed, for example an additional G1170A 5067-4296 Online SPE Multi Cartridge Capillary Kit Capillary Kit Online SPE Multi Cartridge (5067-4296) # p/n Description 2 5067-5112 Capillary ST 0.17 mm x 280 mm SV/M 2 5067-5120 Capillary ST 0.17 mm x 700 mm SL/M 12 5067-5109 Capillary ST 0.17 mm x 90 mm SL/M 1 5023-2504 Hex driver SW-4 slitted 1 G4742-90101 Online - SPE Kits Technical Note 1 G4742-60000 CD with online SPE method 8

Online-SPE-Solution Setup Setting up the Starter Kit G4742A Online-SPE-Solution Setup Setting up the Starter Kit G4742A NOTE This section describes the setup of the Starter Kit only. Refer for the following sections if used in combination with complementary Online-SPE kits. NOTE More application details can be found in the Online - SPE Application Note (p/n 5991-1738EN). Setup the hydraulic path of the Online SPE Starter Set. 9

Online-SPE-Solution Setup Setting up the Starter Kit G4742A Table 1 Capillary Connections for the Starter Kit Part Description Capillary ST, 0.25 mm x 130 mm (01090-87308) Capillary ST 0.12 mm x 340 mm S/S (G1316-87319) Connection Valve - cartridges (4x) Valve crossing (Port 5 Port 10) Valve (port 2) - column use long fittings on valve Capillary ST 0.17 mm x 900 mm S/S (G1329-87300) LC pump - valve (Port 7) Capillary ST 0.17 mm ID 600 mm pre-swaged (5067-4670) Capillary ST 0.25 mm x 250 mm (5065-9979) Pressure Sensor - Autosampler Autosampler - Valve (port 4) Flush pump - pressure sensor (Use PEEK fitting for Flush pump) Waste tubing, 2 m (0890-1713) valve (port 9) 10

Online-SPE-Solution Setup Setting up the Direct Inject Kit G4744A Setting up the Direct Inject Kit G4744A NOTE The Direct Inject Kit can only be used in combination with the G4742A Online SPE Starter Kit. Setup the hydraulic path of the Online SPE Direct Inject Kit. Figure 8 Direct Injection (Valve A in Position 1) Use the capillaries and parts as described in Table 2 on page 12 11

Online-SPE-Solution Setup Setting up the Direct Inject Kit G4744A Table 2 Connecting the Online-SPE Direct Inject Solution by using capillaries from both kits, the Online - SPE Capillary Kit (p/n 5067-4294) and Online - SPE Direct Inject Kit (p/n 5067-4295) Part Description Connection Capillary, 0.25 mm x 280 mm no fittings (5022-6508) Valve A / Port 4 - Valve B / Port 4 Capillary, 0.12 mm x 280 mm (5021-1822) Valve A / Port 3 - Valve B / Port 7 Valve A / Port 7 - Valve B / Port 2 Capillary ST, 0.25 mm x 130 mm (01090-87308) Pressure Sensor - Valve A / Port 10 Valve to cartridges (4x) Valve crossing, Valve B (Port 5 Port 10) Capillary ST 0.12 mm x 340 mm S/S (G1316-87319) Valve A (port 6) - column Autosampler Valve A / Port 5 use long fittings on valve Capillary ST 0.17 mm x 900 mm S/S (G1329-87300) LC pump to valve A (Port 2) Capillary ST 0.17 mm ID 600 mm pre-swaged (5067-4670) Capillary ST 0.25 mm x 250 mm (5065-9979) Valve A (port 1) - Autosampler Flush pump - pressure sensor (Use PEEK fitting for Flush pump) Waste tubing, 2 m (0890-1713) valve B (port 9) Plug Black Long 10-32 (5043-0277) Valve A (port 8, port 9) 12

Online-SPE-Solution Setup Setting up the SPE Multi Cartridge Kit G4743A Setting up the SPE Multi Cartridge Kit G4743A NOTE The Online SPE Multi Cartridge Kit can only be used in combination with the Online-SPE Starter Kit (G4742A) and the Online-SPE Direct Inject Kit (G4744A). Figure 9 Flow path of the direct injection run 13

Online-SPE-Solution Setup Setting up the SPE Multi Cartridge Kit G4743A Table 3 Capillary Connections for the Multi Cartridge Solution Part Description Connection Capillary, 0.25 mm x 280 mm no fittings (5022-6508) Valve A / Port 4 - Valve B / Port 4 Capillary, 0.12 mm x 280 mm (5021-1822) Valve A / Port 3 - Valve B / Port 7 Valve A / Port 7 - Valve B / Port 2 Capillary ST, 0.25 mm x 130 mm (01090-87308) Pressure Sensor - Valve A / Port 10 Valve crossing, Valve B (Port 3 Port 6) Valve crossing, Valve B (Port 5 Port 10) Capillary ST 0.12 mm x 340 mm S/S (G1316-87319) Valve A (port 6) - column Autosampler Valve A / Port 5 use long fittings on valve Capillary 0.17 mm, 900 mm (G1329-87300) LC pump - valve A (Port 2) Capillary ST 0.17 mm ID 600 mm pre-swaged (5067-4670) Capillary ST 0.25 mm x 250 mm (5065-9979) Valve A (port 1) - Autosampler Flush pump - Pressure sensor (Use PEEK fitting for Flush pump) Waste tubing, 2 m (0890-1713) Valve B (port 9) Plug Black Long 10-32 (5043-0277) Valve A (port 8, port 9) Capillary ST 0.17 mm x 280 mm SV/M (5067-5112) Capillary ST 90x 0.17 mm SW-1/16/M4 (5067-5109) Capillary ST 0.17 mm x 700 mm SL/M (5067-5120) Valve B (port 1) - Selection valve 'IN' port Selection valve 'OUT' port - Valve B (port 8) Cartridges - Selection valve In case of combining two Multi Cartridge Solutions: Valve B / Port 3-2nd Selection Valve / IN Port Valve B / Port 6-2nd Selection Valve / OUT Port 14

Installing the Valve Heads Setting up the SPE Multi Cartridge Kit G4743A Installing the Valve Heads The valve drives are factory-installed in the Thermostatted Column Compartment, in the Flexible Cube, and in the 1290 Infinity Valve Drive. The valve heads are interchangeable and can be easily mounted. At the first installation, the dummy valve has to be removed, see Removing the Valve Dummy on page 15. The valve heads can be installed by mounting the valve heads onto the valve drives and fastening the nut manually (do not use any tools). Be sure that the guide pin snaps into the groove of the valve drive thread. Removing the Valve Dummy 1 To remove the valve dummy, loosen the nut manually. 15

Installing the Valve Heads Setting up the SPE Multi Cartridge Kit G4743A Installing the Valve Head and Connecting Capillaries For bio-inert modules use bio-inert parts only! CAUTION The valve actuator contains sensitive optical parts, which need to be protected from dust and other pollutions. Pollution of these parts can impair the accurate selection of valve ports and therefore bias measurement results. Always install a valve head for operation and storage. For protecting the actuator, a dummy valve head can be used instead of a functional valve. Do not touch parts inside the actuator. CAUTION Column Damage or Bias Measurement Results Switching the valve to a wrong position can damage the column or bias measurement results. Fit the lobe to the groove to make sure the valve is switched to the correct position. CAUTION Valve Damage Using a low pressure valve on the high pressure side can damage the valve. When using multiple column compartments as part of a method development solution, make sure that the high pressure valve head is connected to the autosampler and the low pressure valve head is connected to the detector. CAUTION Sample degradation and contamination of the instrument Metal parts in the flow path can interact with the bio-molecules in the sample leading to sample degradation and contamination. For bio-inert applications, always use dedicated bio-inert parts, which can be identified by the bio-inert symbol or other markers described in this manual. Do not mix bio-inert and non-inert modules or parts in a bio-inert system. NOTE The tag reader reads the valve head properties from the valve head RFID tag during initialization of the module. Valve properties will not be updated, if the valve head is replaced while the module is on. Selection of valve port positions can fail, if the instrument does not know the properties of the installed valve. NOTE To have the valve correctly recognized by the Flex Cube you must have the module powered off for at least 10 s. 16

Installing the Valve Heads Setting up the SPE Multi Cartridge Kit G4743A 1 The two different pins (blue & green) on the valve shaft must fit into the corresponding grooves of the actuator axis. The outside pin (red) must fit into the outside groove. 2 It can be possible that you have to turn the valve head until the outside pin completely locks in. While turning the valve you should feel some resistance from the drive. Otherwise the pins on the valve shaft are not properly fitted into the corresponding adapters on the valve drive. 17

Installing the Valve Heads Setting up the SPE Multi Cartridge Kit G4743A 3 When the outer pin is locked into the groove, manually screw the nut onto the valve head. 4 Install all required capillary connections to the valve. NOTE Fasten the nut manually. Do not use any tools. 5 Power on or power-cycle your module, so the valve head gets recognized during module initialization. NOTE Power Off the Infinity valve drive for at least 10 s. 18

Valve Head Parts Information Replacement Parts Valve Head Parts Information Replacement Parts Table 4 Replacement parts Valve Rotor Seal Stator Head Stator Screws Stator Ring 5067-4145 Valve Head 2 Pos/10 Port valve head, 600 bar 5067-4146 Valve head 6 column selector, 600 bar 5067-4137 Valve Head 2 Pos / 6, 600 bar 0101-1415 (PEEK) 5068-0076 (PEEK) 0101-1409 (PEEK) 5068-0165 5068-0019 n.a. 5068-0077 5068-0089 n.a. 0101-1417 1535-4857 5068-0120 19

Valve Head Parts Information Valve Head Parts Valve Head Parts NOTE The figure below illustrates replacement parts for the valve heads, with the 12Pos/13Port Selector valve as an example. The valves can vary in their appearance and do not necessarily include all of the illustrated parts. Neither, every spare part is available for each flavor of the valve. Figure 10 Valve Head Parts (example) 1 Stator screws 2 Stator head assembly 3 Stator ring screws (not available) 4 Stator ring (available for service only) 5 Rotor seal 6 Bearing ring 7 Spanner nut (available for service only) *G4742-90101* *G4742-90101* G4742-90101 Part Number: G4742-90101 Edition: 07/2016 Printed in Germany Agilent Technologies, Inc 2013-2016 Agilent Technologies, Inc Hewlett-Packard-Strasse 8 76337 Waldbronn Germany