Halogen Moisture Analyzer

Similar documents
Number of instruction: LMI-11-02/01/08/ENG-C. Moisture analyzer MBC series

Moisture Analyzer BM 113 User Manual

Moisture analyzer PMC series

Instruction Manual MB90 Moisture Analyzer

Tovatech LLC Phone (973) Rutgers St, Maplewood, NJ 07040

Infrared Moisture Determination Balance FD-610. Operating Manual

This document hosted by: Instruction Manual MB120 Moisture Analyzer

MOISTURE ANALYZER PMC SERIES

Carbon Monoxide Transmitter

Operating instructions for moisture analyzers - UX 3001 (UX 3011, UX 3031, UX 3081) series

MB-T Moisture analyzers

User Manual. Moisture Analyzer HE53

Operating instructions Electronic Moisture Analyser

Instructions for using the PerkinElmer DSC-8500

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

IMR IX176 Portable Gas Detector User Manual

MB23 and MB25 Moisture Analyzers

Operating instructions Electronic Moisture Analyser

Operating Instructions. Moisture Analyzer HE53

Operating Instructions. Moisture Analyzer MJ33

MS-H-Pro-T Magnetic Hotplate-Stirrer with Timer

Infrared Moisture Balance (FD-800)

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station.

INSTRUCTION MANUAL. Stirring hotplate (with probe and stand) Brand : (Dragon laboratory)

Operate the Mutli-Gas Monitor PID

SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof DA-500

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

Operating Instructions Moisture Analyzer HB43-S

Operating Instructions. Moisture Analyzer HE73

EST User Manual. (Please read this manual carefully before using)

Portable Oxygen Monitor OX-07. (Type A) Operating Manual

PDA20DX Air Purifying Dehumdifier Manual

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

Bench-Top Vacuum Oven with 28 segments programmable controller

2-wire Passive Intelligent Loop (LED) Display Meter

Digital 7 Square Plate Magnetic Stirrer

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

E1000 Portable gas detector

IMR EX610. Portable Gas Detector. Operation Manual

2-wire Passive Intelligent Loop (LED) Display Meter

Moisture analysis in minutes - not hours. Metal, Ceramic, Halogen or Quartz The Choice is Yours

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

BST-MG07 Multi-gas Detecting Alarm Manual Instruction

Model D12-IR. Digital Gas Transmitter...

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

Analog Room Pressure Monitor RPC Series

MB23 / MB25 Moisture Analyzer Instruction Manual

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS MD5-601 AND MD5-603

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

Counting Scales. HC-i Series.

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Gas Detection System TOX ALARM DG2000-Garage

Infrared Moisture Balance (FD-660)

HOBO U14 Data Logger User Manual

Refrigerated Incubator Model and Operating Instructions

Forced Convection Constant Temperature Oven. Instruction Manual

BST-MG01 Single Gas Detecting Alarm Manual Instruction

Reacti-Therm I and III Heating Modules

Operating manual Electronic Moisture Analyser

Contents. Outline of Product. Features of Product. Specifications of Product. Name and central function of section. Illustration of Terminal

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

User Manual. MS7-H550-Pro MS7-H550-S MS7-Pro MS7-S

Advance Optima Module Magnos 17

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Optical Fiber Arc Fusion Splicer. Read this user manual carefully before running FX Fusion Splicer. FX Fusion Splicer USER MANUAL. PX EN, Rev.

Reacti-Therm I and III Heating/Stirring Modules

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

Sirius Technologies, Inc.

Magnetic Stirring Systems with Heat

# TFB-S-120, TFB-L-120 TFB-S-220, TFB-L-220 FWS-S-120, FWS-L-120 FWS-S-220, FWS-L-220

ALGS60. Moisture analyzer

XM-18D. Operation Instruction

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

ISHIDA CO., LTD. Do not carry out installation, operation, service or maintenance until thoroughly understanding the contents of this manual.

Contents. Contents

CBI-064. User Manual. Caddx to KNX-BUS Interface

Mini SMT Reflow Oven Model: T-961

ENGINE MONITOR VOTT MODEL: YEAR WARRANTY

CR-1730R User s Manual

Mark 25 Ultrapure Water Conductivity Analyzer

Dual-Mode Infrared Thermometer Instruction Manual

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

CG Series Digital Temperature Controller OPERATIONS MANUAL

DC200 Digital Dispenser Operating Manual

IMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.

COMPASS S3 S2 CALIBRATION

Operation Manual Digital Heating Hotplate HP-1D

Note To The User: This product has updated features not yet mentioned in the product manual.

Gilson Silent Sifter SS-21 & SS-22

Smart Transmitter/ Gas Detector Head

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

FMJ-1600-II-WARM Ving 63" Full - auto Wide Format Roll Heat Assisted Cold Laminator with Stand USER MANUAL

Operating principle. Quinto

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

User Manual. Moisture Analyzer HC103

π H-7241 AIR CUSHION MACHINE PARTS uline.com BOX CONTENTS

Ionizer (Static Remover) STABLO-EX Instruction Manual

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

FTTHARCFUSIONSPLICER AD620

Transcription:

Halogen Moisture Analyzer About the Halogen Moisture Analyzer Mode XY-105MW XY-102MW XY-100MW Specification 110g/5mg 110g/2mg 110g/1mg Readability 5mg 2mg 1mg Tray size Φ 90 Heating mode Halogen Lamp Display LCD Temperature Setting 40 ~199 Time Setting 1~99 minutes ATRO 100%~999% ATRO 0%~999% History store 15 set 1

I Instruction 1. Security Please reading the following before you use the Moisture analyzer a. The instrument can use for test the moisture of the sample,each improper operation may result in personal injury and equipment damage b. Please access the AC power accordance with the manual; c. Please make sure the power cord does not interfere with people action; d. Do not use the instrument under the hazardous,wet or unstable enviroment; e. Unplug the power before you clean the analyzer; f. Please keep enough space around the instrument,and keep the top of the space at least 1m; g. During a special experiment, please wear protective equipment by youself; h. Please do not change the instrument's components and any other aspects. Maintenance of this equipment by the factory authorized professionals Moisture analyzer use Halogen lamp. i. Do not put the flammable materials around the instrument; j. Do touch the halogen lamp when it on working. Special attention to the dangers of some sample; k. Before you test the moisture of dangerous good,pleaes take Full investigation Inflammable and explosive materials:heating the inflammable and explosive materials will produce flammable gases or vapors, so need to lower the temperature in a dry environment. In case of fire or explosion. Toxic and corrosive substance: Keep the samples of toxic or corrosive ingredients in well-ventilated environment. Above the sample test will be particularly careful, for any damage caused by your own risk 2

II.Installation 2.1 Standard Packing List Please check the packaging and accessories. Standard Quantity Note Moisture Analyzer Mainframe 1 set Wind Cover The sample pan holder Tray handle Power cord Aluminum sample tray 1 set 50 pcs of aluminum pan 100g standard weight Product Manual Product certification Warranty card 2.2 Moisture meter placement requirements. Operating table should be stable Temperature stable, dry,without strong vibration without strong magnetic field good ventilation of the environment 2.3 Installation of accessories Place the wind cover, aligned holes. Place the sample tray holder, rotate until positioning. Put the aluminum sample tray on the bracket. 3

2.4 Adjust the level and connect the power There are two feet in front of the instrument,adjust it and keep the instrument level. Connect the instrument with power,put one side of power cord Please warm up more than 30minutes for keep it stable and accurate. III Operation 3.1.Display 3.2.Icon Introdution ----The percentage of dry weight ----Gram ----The percentage of moisture ----Temperature ----Heated mode ---- Time set and heat time ----Standard mode ----Rapid heating mode ---- Gentle heating mode ---- Stop heated mode ---- Automatic -----Manual stop mode ----Timing stop mode ---- Heated state 4

3.3. Keypad 5 NAME ON/OFF START / STOP Key Features Power on / off, Just off the internal DC power supply Start heated/ stop heated TARE MENU CONVERSION ENTER RESET DOWN UP Weighing peeled, Settings exit Enter the setting menu Switching measurement results Confirm the current setting, go to next Return to the weighing mode (short press), calibration balance (long press) Reduce Add 5

3.4 First testing 1. First test, if not change the temperature and time settings, the moisture meter defaults to factory defaults. 2. Put empty sample pan on the holder (see section 2.3). 3. Press the TARE to clean weight. 4.Put the sample on the pan (Sample weight should be heavy than 1g, the general 3-5g). 5. Close the heating cover, press the "Start / Stop" button to start the test. At this point, heated tube lights, fans turn on, heated symbol in the upper left flashing. While rolling on the screen displays the current temperature, has been heating time, moisture content of the current sample. 6. End of the test, heated lamp automatic shut off, the buzzer alarm. Then the sample is displayed on the moisture content, heating time, current temperature and the parameter setting mode.note: Don't touch the sample plate,the temperature is too high now. 7.Press the "Reset" button, the instrument returns to weighing mode. 3.5 Parameters Setting 3.5.1 Heated parameter storage and recall a. The instrument can store a total of 16 0-F group of heated parameters. Each group can set the heating method, stop mode, time and time test parameters.press the"menu" button to enter the parameter setting mode, press the "ENTER" key until the shutdown mode.when flashing.press"up"or"down"to choose the stop mode.and press "ENTER" confirm,parameters are defined, and go to the next parameter (temperature) setting. b. In weighing mode, press the "Settings" button to enter the parameter setting mode, then store the address number (the number show the highest bit) is flashing. Press "down" or "up" key to select the desired address number, the 0 is the factory setting,1-f for the user store. c. The memory address number 0 means factory settings, then click "ENTER" button to exit the settings back to weighing mode. At this point heated mode is the factory defaults. d. When the memory address range for the 1-F any one number, press "ENTER" 6

key, and enter the parameter setting after the completion of a parameter (heated mode, stop mode, time mode) setting.press the "TARE" key, the address number of the test parameters have been stored. 3.5.2 Heated mode and setting( ) a. Standard heated mode:( ) This mode is the factory setting, suitable for most samples. Heating temperature can be set, the sample is heated to a temperature, and keep to the test ends automatically. b. Rapid heating mode: ( ) This mode is suitable for samples with higher moisture content. You can set the heating temperature, heating the temperature will exceeds the set value, the future will be reduced to the set temperature and hold until the test ends automatically. c. Gentle heating mode: ( ) This mode is suitable for low moisture content, surface casing is easy to form, easy to burn the sample. From the heat began to rise to the long time required to set temperature, heating up even slowly. Heating time user selectable. d. Press the "MENU" to enter the parameter setting mode, press the "ENTER" until the heating mode, the icon flashes Press "UP"or"Down"choose the mode you need.and press "ENTER"confirm. 3.5.3 Stop mode setting:( ) a. Automatic stop mode:( ) Heating the sample within the specified time during the weight loss of less than 2mg will automatically stop when the test. This mode after 15 seconds in the heating effect. b. Manual stop mode:( ) Sample heating process is the continuing until the press the "start/stop" button to end testing. c. Timing Stop Mode:( ) 7

Stop time set by the user, the sample heating process is continued until the end of the heating time to set the value of the test. 3.5.4 Heating Temperature Setting The instrument temperature setting range is from 0-199 degrees. Press the "MENU" to enter the parameter setting mode, press the "ENTER" key until the flashing,press"up"or"down"to choose the temperature.and press "ENTER" to go to next setting(time setting) Icon will transform other temperature when its heating. 3.5.5 Heating time setting 1.Just choose timing stop mode need set the stop time. Press the "MENU" to enter the parameter setting mode, press the "ENTER" key until the flashing, Press"UP"or"Down"to choose the temperature.and press "ENTER" 2, Heating cycle:just gentle heating mode need choose heating cycle 3.6 For example: a. sample:water, b. Press the "MENU" to enter the parameter setting mode,choose the ( ),temperature:120,press "ENTER" go to weighing state c. Put a dry paper on the pan,and press"tare" clean the weight. Put on the 3g water on the paper,until the readability stable. Press" START / STOP " begin test. Waiting for it sop.look the result. The m% will be 100%. Weighing error or sample weight deficiency can lead to the result of the test a deviation 8

3.7 Calibration When the instrument error or improper operate. Calibration weights can be adjusted with accuracy. Press "Reset" key and does not release until it display -cal-, Then flashing 100.000, put on the calibration weight, then it will display "= = = = = =", until it display 100.000 remove the weight, it will display "= = = = = = "again, Waiting it show" 0.000 ", the calibration is completed. IV RS232 Setting Baud Rate:1200 Date Bits:7 Odd-even check:no Flow control:continuous Rs232 Commands Commands Function On/Off Power on /Power off g % Conversion results 9

Schedule: Assembly drawing Please installation the instrument according the picture Installation order from top to bottom :1 --2--3--4--5 1. Aluminum scale weighing tray 2. The triangle scale frame 3. Scale tray brackets 4. Wind cover 5. Stainless steel plate 10

Tips: 1. Warm-up the analyzer 30 minutes and take the first time calibration; 2. After the end of a water calibration experiments (see 3.6); 3.Each time the switch machine, please interval of 5 seconds; 4.Cover the heater, do not leave the weight on the pan, or halogen lamps will be crushed; 11